Rural Development Government Departments Closing in 0 days TDR #32848738

Newly Water Supply Scheme At Takli Tarfe Nandapur Tq. Hingoli Dist. Hingoli Under Jal Jeevan Mission (Jjm)

Issued by Government Departments · nandapur, Maharashtra
Tender Value
64.91 Lakhs
Estimated cost
Bid Submission
04 Jul 2022
0 days left
EMD
65000
Bank guarantee accepted
Document Fee
5600
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
nandapur → Maharashtra
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Newly Water Supply Scheme At Takli Tarfe Nandapur Tq. Hingoli Dist. Hingoli Under Jal Jeevan Mission (Jjm)

BOQ

Name of Work Newly Water Supply Scheme atTakli Tarfe Nandapur Tq. HingoliDist. HINGOLI
Sl. No. Item Description
1Percolation WellItem No1115 mm dia Horizontal Bore well 30 m length 4 No.s
2Item No2 Trial Bore of 115 mm dia Bore by helo of Drilling Rig, Machine etc. Complete as directed by Engineer in charge and upto the satisfaction of Engineer in charge. (Including all labours carting, loading, unloading etc) (GSDA DSR 2021 Pg. No. 9 Sr. No. E-1)
3Item No2Excavation in general in soft material comprising of soft soil,soft murum ,sand ,hard murum with boulders in wet or dry condition for head works I.e. intake well ,connecting pipe ,jack well, pump house ,supply well etcfor lift 0 to 1.5 m and lead 150 m including barracading ,guarding ,disposing off surplus excavated stuff with in a radius of 0.5 km as directed by engineer - in -charge etc complete excluding refilling b) for head works on nalla or any other site of GSDA for initil ( M.J.P.CSR 2021-2022P.No 44 I No.10 ) Lift0.00 to 1.50 M
4Lift 1.50 to 3.00 M
5Lift 3.00 to 4.50 M
6Lift 4.50 to 6.00 M
7Item No.4 Excavationin generalinhard material comprisingofsoftrock,hardrock,Manjara rock,etc,byblasting/controlledblasting,chisellingasrequiredinwetordry condition for Head Works i.e. Intake Well, Connecting Pipe, Jack Well, Pump House, supply Well, etc. for lift 0 to 1.5 M and lead of 150 M including baricading, guarding, disposingoffsurplusexcavatedstuffwithinaradiusof0.5km.asdirectedby Engineer-in-charge, excluding refilling Lift 6.00 to 7.50 M MJP SSR 2021-22 Item No. 11.a PG. No. 45
8Lift 7.50 to 9.00 M
9Lift 9.00 to 10.50 M
10Lift 10.50 to 12.00 M
11Lift 12.00 to 13.50 M
12Lift 13.50 to 15.00 M
13Lift 15.00 to 16.5 M
14Lift16.5to 18.00 M
15Item No.5 Providingandlayingin situ followinggradesofcementconcreteoftrap/ granite/ quartzite /gneiss metal for foundationand bedding including dewatering,form work, compaction, curing, finishing etc. complete.a) M-150 MJP SSR 2021-22 Item No. 2.a PG. No. 49
16Item No.6 Providing and casting in situ c.c. of trap/ granite/ quartzite/ gnesis metal of approved quality for RCC works as per detailed drawings and designs or as directed including normal dewatering,centering,form work, bally, steel propups,compaction,finishing the formed surfaceswith C.M.1:3 of sufficientminimumthicknessto give asmooth andevensurface whereevernecessaryorrougheningif specialis to be provided and curing etc. complete ( By weigh batchingand mix design for M-250 and M-300 only.Use of L&T, A.C.C.Ambuja,BirlaGold, Manikgad,Rajashree,etc. cementis permitted.)( Excluding M.S. reinforcements)RCC M-200 for water retaining structure a) For RingBeam BottomRing MJP SSR 2021-22 Item No. 2.d PG. No. 49
17a) ForVertical Wall (6 m below GL & 1.5 m above GL ) Above 1.5 m from GL
18From GL to Below 5 m
19Item No. 7 Providingand fixingin positionsteel bar reinforcementof variousdiametersfor RCC piles, caps, footings, foundations,slabs, beams, columns, canopies, staircase, newels,chajjas,lintels,pardies,copings,fins,arches,etc. as per detailed designs, drawingsandschedulesincludingcutting,bending,hookingthebars,bindingwith wiresor tackweldingand supportingas required,etc.complete.(includingcost of binding wire)1% of RCC Qty Lift0 to 5 m above GLMJP SSR 2021-22 Revised Item No. 8.b PG. No. 52
20Lift0 to 5 m below GL
21Item No.8Providingstucturalsteelworkin single stanchionscomposedof RSJ, channel,etc, withcaps,bases,mildsteel plates,angles,brackets,cleats,gussetplates,anchor bolts, etc. as per detaileddesign and drawing or as directed by Engineer-in-charge includingcutting,fabrication,hoisting,erecting,fixinginposition,makingriveted/bolted/weldedconnectionsandonecoatsofanticorrosivepaintandoverittwo coats of oil painting, etc. complete. RSJ 200x100mm Weight of RSJMJP SSR 2021-22 Item No. 2.d PG. No. 49
22Item No. 9 Providingand fixing M.S. chequerredplate flooringof following thicknesssupported onM.S.angles(25x25x5 mmsize)includingwelding,cuttingandfabricatingthe plates to the requiredsquare or rounding shape,makingholes in the plate, includingprovidingandapplying3coatsofanticorrosivepaint,etc.completeasdirectedby Engineer-in-charge.6 mm thickMJP SSR 2021-22 Item No. 6.a PG. No. 229
23ITEM NO.10 Dewateringtheexcavatedtrenchesandpoolsofwaterinthe buildingtrenches/ pipeline trenches,well works by using pumps and other devices including disposing offwatertosafedistanceasdirectedbyEngineer-in-charge(includingcostof machinery, labour, fuel), etc. complete.7.5 BHP pumps daily 8 hrs for 40 days MJP SSR 2021-22 Item No. 6.a PG. No. 229
24ITEM NO.11 Providing and fixing in position C.I. dapuri steps for 22 mm dia. M.S. step with proper anchorage,etc.andprovidingandapplying3coatsofant-corrosivepaint,etc complete as directed by Engineer-inchargeMJP SSR 2021-22 Item No.11PG. No. 230
25ITEM NO.12Providing, and fixing 80 mm dia A.C. / P.V.C. pipe weep holes at 1.5 m.c/c staggered including costofallmaterialsandlabourinvolvedwithallleadsandlifts.etc.complete with all leads and liftsMJP SSR 2021-22 Item No.5PG. No. 229
26ITEM NO.13 Refillingthe trencheswith available excavatedstuff with soft material first over pipe lineandthenhardmaterialin15cmlayerswithall consolidation, surcharging etc. complete.MJP SSR 2021-22 Item No. 15PG. No. 45
27ITEM NO.14 Carrying out recuperation/ yield test for asserting the discharge of constructed well/ excavated profile as directed by Engineer-incharge. The test is carried out by drawing down water from the well/profile below normal/ subsoil water level upto full depth rise in water level is recorded. The normal water level/ subsoil water level in the well/ profile as well as stainer/ suction level at pump as per design of W.S. scheme shall be recorded prior to the test including cost of all materials, overhead, labourers, etc. completed as directed.Lps less than 25,000 MJP SSR 2021-22 Item No. 17PG. No. 231
28Switch Room (For Percolation Well ) Item No1 Excavation for foundation / pipe trenches in earth, soils of all types, sand, gravel and soft murum, including removing the excavated material upto a distance of 50 metres and lifts as below, stacking and spreading as directed, manual dewatering, preparing the bed for foundation and excluding backfilling, etc. complete.Lift of 0 to 1.5 M(MJP DSR 20-21, Sr. No. 01, P.No. 42 )
29Item No. 2 Excavation for foundation / pipe trenches in hard murum including removing the excavated material upto a distace of 50 M and lifts as below, stacking and spreading as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete.Lift of 0 to 1.5 M(MJP DSR 20-21, Sr. No. 02, P.No. 42 )
30Item No.3 Providing and laying in situ Cement concrete M-15of trap or granite or quartzite or gneiss metal for foundation and bedding includingdewatering, form work, compacting,roughening them if special finish is to be provided, finishing if required and curing etcetera complete.PCC (M-150) (MJP DSR 20-21, Sr. No. 01, P.No. 49 )
31Item No.4 Providing and laying in situ Cement concrete of trap/granite/quartzite/ gneiss metal for RCC work in foundation like raft, grillage, strip foundation and footing of RCC columns and steel stanchions including normal dewatering, form work, compaction, finishing and curing, etc, complete. (By weigh batching and mix design for M-250 and M-300 only. Use of L & T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) Excluding M. S. orTor ReinforcementRCC Footings ( M-200)(MJP DSR 20-21, Sr. No. 02/c, P.No. 49 )
32Item No.5 Providing and casting in situ Cement Concrete of trap/granite/quartzite/ gneiss metal of approved quality for RCC work as per detailed drawings and designs or as directed by Engineer-in-charge including normal dewatering, centering, form work, compaction, finishing the formed surfaces with CM 1:3 of sufficient minimum thickness if special finish is to be provided and curing, etc. complete. (By weigh batching and mix design for M-250 and M-300 only. Use of L&T, A.C. C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted )RCCCOLUMNS ( M-200)(MJP DSR 20-21, Sr. No. 03/b, P.No. 49 )
33Item No.6 Providing and casting in situ C. C. of trap / granite / quartzite/ gneiss metal of approved quality for RCC works as per detailed drawings and designs or as directed by Engineer-in-charge including normal dewatering, centering, form work, compaction, finishing the formed surfaces with C. M. 1:3 of sufficient minimum thickness to give a smooth and even surface wherever nesessary or roughening if special finish is to be provided and curing, etc. complete. (By weigh batching and mix design for M-250 and M-300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) RCCBEAMS & lintel( M-200)(MJP DSR 20-21, Sr. No. 04/b, P.No. 50 )
34Item No.7 Providing and casting in situ C. C. of trap/granite/quartzite/ gneiss metal of approved quality for RCC work as per detailed drawings and desingns or as directed by Engineer-in-charge including normal dewatering, centering, form work, compaction, finishing the formed surfaces with CM 1:3 of sufficient minimum thickness to give a smooth and even surface wherever necessary or roughening if special finish is to be provided and curing, etc. complete. (By weigh batching and mix design for M-250 and M-300 only. Use ofL&T, A.C. C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted .) Slab & Landing steps ( M-200)(MJP DSR 20-21, Sr. No. 06/b, P.No. 51 )
35Item No.8 Providing and casting in situ C. C. of trap/granite/quartzite/ gneiss metal of approved quality for RCC work as per detailed drawings and designs or as directed by Engineer-in-charge including normal dewatering, centering, form work, compaction, finishing the formed surfaces with CM 1:3 of sufficient minimum thickness to give a smooth and even surface wherever necessary or roughening if special finish is to be provided and curing, etc. complete. (By weigh batching and mix design for M-250 and M-300 only. Use fo L&T, A.C. C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted .) Excluding M S or Tor reinforcement. Chajja ( M-200) (MJP DSR 20-21, Sr. No. 13/b, P.No. 55 )
36Item No. 9 Providing second class Burnt Brick masonry with conventional / Indian Standard type bricks in cement mortar of following proportion superstructure including striking out & racking out joint watering and scafolding etc complete. (PWD SSR 21-22 P.NO.144 I.NO 27.05)
37Item No. 10 Providing second class Burnt Brick masonry with conventional / Indian Standard type bricks in cement mortar of following proportion superstructure including striking out & racking out joint watering and scafolding etc complete. (PWD SSR 21-22 P.NO.144 I.NO 27.05)
38Item No. 11 Providing and fixing in position steel bar reinforcement of various diameters for RCC pipes, caps, footings, foundation ,slabs, beams, columns, canopies, staircases. newels, chajjas, lintels, pardies, copings, fins, arches, etc. as per detailed designs, drawings and schedules; including cutting, bending, hookingthe bars, binding with wires or tack welding and supporting as required, etc. complete.(including cost of binding wire) Tor SteelMJP SSR 21-22 (revised) pg no. 13 Section-A
39Item No.12 Providing and laying Rough Shahabad Stone Flooring 25 mm to 30 mm thick and of required width in plain /diamond pattern on a bed of 1:6 C.M. including cement float ,striking joints ,pointing in cement mortar 1:3 curing and cleaning etc. complete. (PWD SSR 21-22 P.NO.156 I.33.01)
40Item No.13 Providing internal cement plaster 12 mm. thick insingle coat in cement morter 1:5 without neeru finish toto concrete or brick surfaces,in all positions inculding scffolding and curing complete.(Bd-L-5/368) (PWD SSR 21-22 P.NO.153 I.33.05)
41Item No.14 Providing sand faced plasterexternally in cement motar using approved screened sand, in all positions including base coat of 15 mm. thick in cement mortar 1:4 using waterproofing compound at 1 Kg. per cement bag, curing the same fornot less than 2 days and keeping the surface of the base coat rough to recive the sand faced tretment 6 to8 mm. thick in cement mortar 1:4 finishingthe surface by taking out grains and curing for foureen days scaffolding etc. complete. (PWD SSR 21-22 P.NO.153 I.32.11)
42Item No.15 Provinding and applying white-wash in Two coat on old/ new plastered or masonry surfaces and asbestos cement sheets including scaffolding and preparing the surface by brushing and brooming down complete.(236 Bd-P-1-A)(PWD SSR 21-22 P.NO.218 I.36.02)
43Item No.16 Provinding and applying washable oil-bound distemper of approved colour and shade to old and new surface in two coats including scaffolding preparing the surfaces (excluding the primer coat) etc.complete.(Bd-P-5/413) (PWD SSR 21-22 P.NO.167 I.36.11)
44Item No.17 Providing and fixingsteelframe of angle 50X 50X 6 mm for windows with 16mm with mild steel bar horizantally at 10 cm c/c for ventilator portion and at 15 cm c/c for remaining portion with M.S. flat of size 40x6 mm vertical at center including iron hold fast boxes for fixing 40x6 mm vertical at center including iron .PWD S.S.R. I.No. 1152/39.35P.No. 313 (PWD SSR 21-22 P.NO.182 I.39.33)
45Item No.18 Providing and fixing in position factory made box type steel window with glazed fanlight including steel windows of cold rolled section of 105mm x 60mm x 1.25mm thick frame section filled with cement concrete (1:2:4) and metal pressed steel shutters of 20 gauge (1mm) as per detailed drawing and design or as directed including providing horizontal mild steel 12mm square bars at 10cm center to center, required F7B section, section 76, section 20mm x 5mm mild steel flat for shutter and F4B section for frame, 3mm thick glass of approved quality for fanlight necessary fixtures and fastening etc. complete finishing with one coat of anticorrosive paint etc.complete(PWD SSR 21-22 P.NO.181 I.39.22)
46Item No.19 Providing and fixing steelframe door of angle 50X 50X 6 mm with 16mm with mild steel bar horizantally at 10 cm c/c for ventilator portionincluding iron hold fast boxes for fixing shutters including welding, finishing,painting etc complete.(PWD SSR 21-22 P.NO.182 I.39.35)
47Item No.20Providing and fixing 34 mm thick moulded door shutter consisting of solid core single leaf flush door of 30 mm thickness lipped with 15 mm ( 5mm x 3) thick x 30 mm width on one style and top rail and 10 mm (5mm x 2) thick x 30 mm width on other style and bottom rails. The inner panels laminated with 2 mm thick termite proof, water proof and fire resistant moulded PVC sheet with 2,4,6 design in different plain and /or prelim colours on one side after routing the moulded design on flush doors and 2 mm plain and /or pre lam PVC on other side using rubber adhesive on flush door and solvent cement adhesive on the PVC lipping etc. as per direction of Engineer in charge and manufacturers specification and drawing etc. complete. (PWD SSR 21-22 P.NO.186 I.39.48)
48Item No.21 Refilling the trenches with available excavated stuff with soft material first over pipeline and then hard material in 15 cm layers with all leads and lifts including consolidation, surcharging, etc. complete. (MJP SSR 21-22 P.NO.45 I.15)
49PUMPING MACHINARY FOR PR.SOURCE 7.5 BHP Item No.1Providing, erecting and giving tests of submersible pump set confirming to IS 8034 and motor confirming to IS 9283, with water proof winding and discharge with stainless steel shaft. Mortar suitable for working on 415 V = 10% 3 phase 50 Hz A.C. supply with cable guard, thrush carbon/fible bearing to withstand entire hydraulic thrust with suitable suction strainer, pump should have suitable discharge outlet as per manufacture\"s design. Antithrust streamlined run and 2 pairs of erection clamps 80 mm width non return valve.Submersible pump 150 mm dia (with bronze impeller upto 8 stages). Submersible Pump 150mm (with Bronze/ Stainless steel Impeller) 7.5 BHP suitable for 50 mtr head & 13614 litres/hr discharge. (MJP MECH SSR 21-22 P.NO.1 PM 1-2-5)
50Item No.2 Providing and Fixing L.T. skeleton panel board upto 7.5 HP. (As per detail sheet attached)
51Item No. 3 Supplying and erecting flat flexible 3 core 4 sq mm PVC sheathed submersible type copper cable suitably clamped at fixed intervals with column pipe assembly complete. (PWD Elect. CSR 2021-22 P. No. 218 I. No. 12-4-9)
52Item No.4 Providing & erecting ISI mark G.I. pipeof followingclassanddia. including all local and central taxes, octroi, inspection charges, transportation to stores, etc. complete 80 mm dia (heavy) on well (MJP CSR 2021-22 P. No. 82 l. No. 1.III.1.c.vii)
53Item No.5 Providing, supplying and fixing ISI mark CI D/F Reflux valve (non-return valves of following dia including all taxes (central and local), railway freight, inspection charges, unloading from railway wagon, loading into truck, transportation upto departmental store/site, unloading, stacking etc. complete. Reflux valves as per I.S. 5312 part I (1984)a) Without bypass arrangement - PN - 1100 mm dia(MJP CSR 2021-22 P. No. 131 l. No. 1 a). v)
54Item No.6 Providing and fixing double flanged sluice valve confirming for IS-2096/14846 including worn gear arrangements as per test pressure stainles steel spindle, caps including all taxes transportation etc complete.a) Sluice valve - PN - 1(Without bypass) 100 mm dia(MJP CSR 2021-22 P. No.132l. No. 2Aiii)
55Item No.7 Lowering, laying and jointing in position following C.I.D/F Reflex valves, Butterfly valves and Sluice valves including cost of all labour jointing material, including nut bolts and giving satisfactory hydraulic testing etc. complete. (Rate for all class of valves.) a) Sluice valve - PN - 1(Without bypass) 100 mm dia(MJP CSR 2021-22 P. No.132l. No. 2Aiii)
56Item No. 8 Providing and erecting pressure gauge of required capacity complete with syphon tube, isolating cock suitable for 12mm dia GI pipe. Pressure gauge shall be installed as directed, with tapping on rising main pressure gauge (100 mm dia) (MJP Mech. CSR 2021-22 P. No.7 PM11-1)
57Item No.9Providing earthing with galvanized iron earth plate size 60 x60 x 0.6 cm with funnel with a wire mesh for watering and brick masonry block C.l. cover complete with all materials, testing & recording the results as per specification no. EA-EP.Plate type Electrode (IS 3043) 1. For pump - 1Nos1. For panel board- 1No. (PWD Elec. CSR 2021-22 Item No. 9-1-3)
58Item No. 10 Providing and supplying ISI standard CI Flanged/ S&S specials including all taxes (Central and local), railway freight, insurance, unloading from railway wagon, loading into truck transport to departmental store/site, unloading stacking etc. complete.CI D/F specials i) 80 to 300 mm dia(MJP CSR 2021-22 Section-I(I) P. No. 72 l. No. 6ai)
59Rising Main ITEM NO.1 Providing and supplying in standard lengths ISI mark rigid unplasticised PVC pipessuitable for potable water with solvent cementjoints including cost of couplers, as per ISspecification no. 4985 / 1988 excluding GSTlevied by GOI and GOM in all respect, includingtransportation, freight charges, inspectioncharges, loading, unloading, conveyance to thedepartmental stores and stacking the same inclosed shed duly protected from sun rays andrains including cost of jointing material i.e.solvent cement, etc. complete (selffit type to bejointed with cement solvent). Proposed Well to Junction(110mm PVC 6 Kg/cm2)
60Junctionto ProposedGSR(90 mm PVC 6 Kg/cm2)
61Junctionto Existing ESR(90 mm PVC 6 Kg/cm2)
62Providing and supplying ISI standard pvc specials & fittings including transportation to stores/ site,loading,unloadingchargesexcludingGSTleviedby GOI & GOM,etc. complete.10% cost of pipes
63ITEM NO. 2Providing ISI standard R.C.C. pipes in standard lengths of following class and diameter suitable for either collar joints or rubber ring joints Including all taxes (Central and local) ,InspectionRCC PIPES NP III Considering Nalla / Road Crossing200 mm dia RCC NP III PIPES
641% cost of pipes MJP SSR 2021-22 Section I (e) Page No. 97
65ITEM NO. 3 Providing double flange sluice valve confirming for IS- 14846 including worn gear arrangements as per test pressure, stainless steel spindle, caps, including inspection charges, transportation upto departmental store, unloading, stacking excluding GST levied by GOI & GOM in all respect etc. completea) Sluice valves - PN -1 Without byepassarrangement80 mm Dia For Sluice (MJP SSR 2021-22 P. No 132 I.No 2ai)
66ITEM NO. 4 Providing and supplying ISI mark CI D/F reflux valves (non-return valves ) of following dia including railway freight, inspection charges, unloading from railway wagon, loading into truck, transportation upto departmental stores, unloading, stacking excluding GST levied by GOI & GOM in all respect etc. complete.Reflux valves as per I.S.5312 Part I (1984)a) Reflux valves - PN -1 Without byepassarrangement 100 mm Dia(non-return valve ) (MJP SSR 2021-22 P. No 131 I.No 1a iii to viii)
67Item No.5Providing and supplying Air Valves as per IS- 14845-2000 and MJP’s standard specifications of approved make and quality of following diameters including railway freight, inspection charges, unloading from railway wagons, loading into truck, transportation upto departmental stores, unloding and stacking excluding GST levied by GOI & GOM in all respect etc. complete. a) Air valve Single ball Flanged - PN -1 40 mm dia (MJP SSR 2021-22 P No.135 I.No.5 b)
68Mechanical Tee 100x100x100 mm(MJP SSR 2021-22 P. No 148 I.No 8/a/1)
69ITEM NO.6Labour SectionExcavation for foundation / pipe trenches in earth, soils of all types, sand, gravel and soft murum, including removing the excavated material upto a distance of 50 metres and lifts as below, stacking and spreading as directed, manual dewatering, preparing the bed for foundation and excluding backfilling, etc. complete.Lift 0 to 1.5 MJP DSR 2021-22 SECTION- E Sr.No.1 pg.no.42
70ITEM NO. 7 Excavationfor foundation/ pipe trenchesin hard murumand boulders,W.B.M. road includingremovingthe excavatedmaterialupto a distanceof 50 M beyond the area and lifts as below, stacking and spreading as directed by Engineer-in-charge, normal dewatreing, preparing the bed for foundation and excluding backfilling, etc. complete. Lift 0 to 1.5 MMJP DSR 2021-22 SECTION- E Sr.No.2 pg.no.42
71ITEM NO.8 Excavationfor foundation/ pipe trenchesin soft rock&old cement& lime masonary foundation,asphaIt raod includingremoving the excavated material upto a distance of 50 metres and lifts as below, stacking and spreading as directed, manual dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. Lift 0 to 1.5 MMJP DSR 2021-22 SECTION- E Sr.No.5 pg.no.42
72ITEM NO.9Excavation for foundation / pipe trenches in hard rock by controlled blasting, including trimming and levelling the bed by chiselling where necessary and removing the excavated material and stacking it in measurable heaps within a distance of 50 metres from the area and lifts as below, normal dewatering, excluding backfilling, etc. complete. (Bd-A-5/259)Lift 0 to 1.5 M
73ITEM NO. 10 Filling inplinth floors murum bedding intrenches with approved murum from excavatedmaterialsfromfoundation15to20cmlayersincludingwateringand compaction complete. Murum selected from excavated stuff MJP DSR 2021-22 SECTION- E Sr.No.16 pg.no.45
74ITEM NO.11 Lowering Laying and jointing with P.V.C pipes and specials of following class and diameter including cost of conveyance from source to site of works including cost of all labour,material,except cement solvent,rubber ring,as per IS code etc.complete (with cement solvent joint/ring fit joint). 110 mm dia
7590 mm dia
76ITEM NO. 12 Hydraulic testing of PVC pipe line to specified pressure includingcost of all materials and labour and water for testing for specified length including cutting, placing end cap makingarrangement forfillingsafewaterusingreciprocatingtypepumpswhich shouldbeabletoprovidespecified testpressuregaugesandothernecessary equipments,labour,operationcharges,etc. requiredfor testing.The rate underthis itemshallalsoincludecostofretesting,ifnecessaryandreinstatingtooriginal position Working pressure 6 kg/cm2 110 mm Dia. MJP SSR Section I (II) Page No. 80 b) iii , iv)
7790 mm dia
78ITEM NO. 13 Lowering, laying and jointing in proper grade and alignment R.C.C. pipes with collar joints in C.M.1:1 proportion or socketed R.C.C. pipes with rubber joints (excluding cost of rubber ring or R.C.C. collar,) including cost of conveyance from stores to site of work, cost of jointing material, labour, etc. complete as directed by Engineerin- charge (For all class of pipes.) as per IS- 783-1985. 200 mm dia RCC NP III PIPES (MJP SSR 2021-22 P No.98 section I (V) 2. iv)
79ITEM NO. 14 Lowering, laying, jointing in positionfollowing scour, butterfly valves and sluice valves including cost of all labors jointing material including nutbolts and giving satisfactory hydraulic testing etc complete ( Rates for all class of valves ) )80 mm Dia For Sluice
80100 mm Dia For Sluice(MJP SSR 2021-22 P No.135 I.No.4a)
81ITEM NO. 15 Lowering, laying, jointing in positionfollowing scour, butterfly valves and sluice valves including cost of all labors jointing material including nutbolts and giving satisfactory hydraulic testing etc complete ( Rates for all class of valves ) 100 mm Dia(non-return valve )
82ITEM NO. 16 Providing and fixing in position air valve shaft including providing and fixing GI Medium Class or 6 mm thick M.S. pipe shaft 2.70 M long over branch flange of air valve tee, providing PCC block of M-150 concrete, 150 mm thick around the air valve tee including encasing of vertical shaft in PCC M 150 as shown in type design together with providing and making flanged joints wherever required and fixing of air valve tee, etc. complete as per type design and as directed by Engineer -in- charge for following diameters of pipe lines (type design attached) Upto 150mm 40 mm dia
83ITEM NO. 17Providing and constructing B.B. masonry valve chamber with 15 cm thick 1:3:6 proportion PCC bedding, excluding excavation, B.B. masonry in CM 1:5 proportion,precast RCC frame and cover, etc. Complete as directed by engineer-in-charge. Note: Wall thickness : 0.23 M for depth of .2 M and 0.35 M for balance depth exceeding 1.2 M. As above of 60x45 CM internal size and depth upto 0.9 M with precast R.C.C slab cover (MJP SSR 2021-22 P No.220 I.No.1a)
84ITEM NO. 18 Refilling the trenches with available excavated stuff with soft material first over pipeline and then hard material in 15 cm layers with all leads and lifts including consolidation, surcharging, etc. complete. (MJP SSR 2021-22 P No.45 I.No.15)
85Distribution System ITEM NO.1 Material. Providing and supplying in standard lengths ISI mark rigid unplasticised PVC pipes suitable for potable water with solvent cement joints including cost of couplers, as per IS specification no. 4985 / 1988 excluding GST levied by GOI and GOM in all respect, including transportation, freight charges, inspection charges, loading, unloading, conveyance to the departmental stores and stacking the same inclosed shed duly protected from sun rays and rains including cost of jointing material i.e.solvent cement, etc. complete (self fit type to be jointed with cement solvent).MJP SSR 2021-22 Section I (II) Page No. 76 Working Pressure 4 kg/cm275 mm
8690 MM
87110 mm
88Providing and supplying ISI standard PVC & GI specials and fittings including transportation to stores/site, loading, unloading charges excluding GST levied by GOI & GOM, etc. complete.10% of cost of pipes
89ITEM NO.2 Providing ISI standard R.C.C. pipes in standard lengths of following class and diameter suitable for either collar joints or rubber ring joints Including all taxes (Central and local) ,Inspection RCC PIPES NP III Considering Nalla / Road Crossing200mm dia RCC NP III PIPES
901 % For Specials of Pipe cost
91ITEM NO.3 Providing double flange sluice valve confirming for IS- 14846 including worn gear arrangements as per test pressure, stainless steel spindle, caps, including inspection charges, transportation upto departmental store, unloading, stacking excluding GST levied by GOt & GOM in all respect etc. complete.Without by pass arrangement - PN-1.MJP DSR 2021-22 SECTION- E Sr.No.2 pg.no.42. 65 mm sluice valve
9280 mm sluice valve
93ITEM NO.4 LABOUR Excavation for foundation / pipe trenches in hard rock and concrete road by chiselling, wedging, line drilling by mechanical means or by all means other than blasting including trimming and levelling the bed, removing the excavated material upto a distance of 50 metres beyond the area and lifts as below, stacking as directed by Engineer-in-charge, normal dewatering, excluding backfilling, etc. complete by all means. (Bd-A-6/259)Lift 0 to 1.5MJP DSR 2021-22 Section E Sr.No.7 Pg.No.42
94ITEM NO.5 Excavationfor foundation/ pipe trenchesin hard murumand boulders,W.B.M. road includingremovingthe excavatedmaterialupto a distanceof 50 M beyond the area and lifts as below, stacking and spreading as directed by Engineer-in-charge, normal dewatreing, preparing the bed for foundation and excluding backfilling, etc. complete.Lift 0 to 1.5. MJP DSR 2021-22 Section E Sr.No.3 Pg.No.42
95ITEM NO.6 Excavation for foundation / pipe trenches in earth, soils of all types, sand, gravel and soft murum, including removing the excavated material upto a distance of 50 metres and lifts as below, stacking and spreading as directed, manual dewatering, preparing the bed for foundation and excluding backfilling, etc. complete.Lift 0 to 1.5MJP DSR 2021-22 Section E Sr.No.1 Pg. No. 42
96ITEM NO.7 Excavation for foundation / pipe trenches in hard murum including removing the excavated material upto a distace of 50 M and lifts as below, stacking and spreading as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete .Lift 0 to 1.5MJP DSR 2021-22 Section E Sr.No.2 Pg. No.42
97ITEM NO.8 Excavation for foundation / pipe trenches in soft rock and old cement and lime masonry foundation asphalt road including removing the excavated material upto a distance of 50 M beyond area and lifts as below, stacking as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. Lift 0 to 1.5 MJP DSR 2021-22 Section E Sr.No.5 Pg.No.42
98ITEM NO.9 Filling in plinth and floors murum bedding in trenches with approved murum from excavated materials from foundation 15cm to 20cm layers including watering and compaction complete.Murum selected from excavated stuff MJP DSR 2021-22 Section E Sr.No.16 Pg.No.45
99ITEM NO. 10 Lowering Laying and jointing with P.V.C pipes and specials of following class and9 diameter including cost of conveyance from source to site of works including cost of all labour,material,except cement solvent,rubber ring,as per IS code etc.complete (with cement solvent joint/ring fit joint) Working Pressure 4 kg/cm2 MJP DSR 2021-22 Section I(II) Sr.No.4 Pg. No.80 Working Pressure 4 kg/cm275 mm
10090 mm
101110 mm
102ITEM NO.11 Hydraulic testing of PVC pipe line tospecified pressure including cost of allmaterials and labour and water for testing forspecified length including cutting, placing endcap making arrangement for filling safe waterusing reciprocating type pumps which shouldbe able to provide specified test pressuregauges and other necessary equipments,labour, operation charges, etc. required fortesting. The rate under this item shall alsoinclude cost of retesting, if necessary andreinstating to original position.MJP SSR Section I(II) Pg. no. 80 Working Pressure 4 kg/cm275 mm
10390 mm
104110 mm
105ITEM NO.12 Lowering, laying and jointing in proper grade and alignment R.C.C. pipes with collar joints in C.M.1:1 proportion or socketed R.C.C. pipes with rubber joints (excluding cost of rubber ring or R.C.C. collar,) including cost of conveyance from stores to site of work, cost of jointing material, labour, etc. complete as directed by Engineerin- charge (For all class of pipes.) as per IS- 783-1985.Considering Nalla / Road Crossing. 200 mm RCC Class \"NP-III\" Pipe. MJP SSR 2021-22 Section 2 Page No. 98
106ITEM NO.13 Lowering, laying, jointing in positionfollowing CI/DF Reflux, butterfly valves and sluice valves including cost of all labors jointing material including nutbolts and giving satisfactory hydraulic testing etc complete ( Rates for all class of valves ) MJP DSR 2021-22 Item No. 4a Sec. I (XII)pg.no.135 65 mm sluice valve
10780 mm sluice valve
108ITEM NO.14 Providing and fixing C.I. road box including loading, unloading and carting to site of work including all necessary excavation in all types of strata and fixing in murum packing, etc. complete. 100 mm x 225 mm (20kg). MJP DSR 2021-22 Item No. 5a pg.no.223
109ITEM NO.15 Providing and laying in situ Cement Concrete M-15 of trap/ granite / quartzite / gneiss metal for foundation and bedding including bailing out water, form work, compaction, curing, etc. complete. (Cement 5.90 bags / cum)Spec. No. - Bd E /1 Page No. 287 and B-7, Page No. 38
110ITEM NO.16 Refilling the trenches with available excavated stuff with soft material first over pipeline and then hard material in 15 cm layers with all leads and lifts including consolidation, surcharging, etc. complete. Net volume of refilling. MJP DSR 2021-22 Item No. 16 Sec.E pg.no.45
111CHLORINATION ARRANGEMENT ITEM NO.1 Providing and installing simplegravityfeed disinfection arrangement with TCL powder solution on the percolation well / service reservoir including solution tankfeeding pipe, dosing arrangement all other accessories giving tgrialand test etc. complete. Drip Type Chlorinator 2 set
112TRIAL & RUN OF SCHEME ITEM NO.1 Commisioning running and maintaining the scheme to quantities, rate capacity, including manning necessory personnel such as operator, valveman, etc, as pr requirements of the scheme and who should also administer chemical dose for a period of one month for individual scheme together with training of personnel spared by MJP/ Local Body and handling over the scheme to Local Body after completion of the above period as directed by Engineer - in charge. For single village (1 Month) (M.J.P. SOR 21-22 P. No 232 I.No.1a)
113Fencing and M.S. gateFor Percolation welITEM NO.1 Providing & erecting chain link fencing 1.6 Mtr height with GI chain link of size 50*50 mm 8 SWG thick and fixed 75 mm above GL vertical M.S. angle of 40*40*6 mm size embedded in cc block 1 :4 :8 mix of size 450*450*670 mm at 1.75 m centre to centre wiyh iron bar 16 mm dia as a hold fast including welded link with angle frame at 30 cm cenre to centre nuts & bolts & horizontal MS angle at top & bottom of 25 * 25* 5 mm size & vertical MS flat 35 * 5 mm & 25 * 5 mm horizontal including cross supports of 40 *40*6 mm angle both sides at every corner in cc with 3 coat of oil painting etc complete. PWD SSR 2021-22 I.No 46.39 BDW P.No.217
114ITEM NO.2 Providing and fixing M.S. gate 2.5 Mwide for compound with 40 mm dia G.I.pipe, approved grill work, RCC M-150 sidepillars of 25 cm x 40 cm x 2.5 M height, itsfoundation, finishing, painting, etc.complete.MJP SSR Section-H: Miscellaneous P.No.58
115ITEM NO.3 Providing and fixing board displaying information, such as \"Name of work, Tender cost, Name of Contractor, work completion and liability period etc\", having rectangular shape of 1.20m * 0.90m size made out 18 gauge (1.25mm) thick mild steel sheet painted with one coats of Zinc chromate stoving primer and two coats of enamel paint on front side and grey stove enamel on back side and border/ messages / symbols etc. with approved colour shade paint complete, on M.S,angle of size 35 * 35 *3 mm frame with properly cross braced M.S. angles of size 35mm*35mm*3mm duly painted including Two M.S. angle iron posts of size 65 mm * 65 mm *6 mm, 3.65m long painted with alternate black and white bands of 25 cm width including all fixtures etc. and fixing the boards in 1:4:8 concrete block of size 60 cm *60 cm *75 cm including, excavtion, refilling, transportation and labour etc complete. Spec. No. As directed by Engineer in Charge SSR I.No. 6.96
116RCC GSR OF CAPACITY 38000 LITRES ITEM NO.1 Designing (aesthetically), and constructing RCC ground service reservoirs / RCC sumps in M-300 mix of required capacity including excavation in all types of strata, foundation concrete, container walls, bottom slab top RCC roof slab / or dome, 20 mm thick cement plaster with water proofing compound in CM 1:3 proportion to inside face of the container, including epoxy paint from inside including refilling and disposing of surplus stuff within lead of 50 M, all labour and material charges, for laying and jointing of pipe assembly for inlet, outlet washout, over flow and bypass arrangement consisting of C.I. M.S. D/F. pipes, specials and valves of given diameters, providing and fixing accessories such as M.S. ladder inside and outside, C.I. Manhole frame and cover, water top slab, B.B. masonry chamber for all valves, ventilating shafts, including giving satisfactory hydraulic test and water tightness test as per IS code and providing three coats of cement paints to all exposed surface of structure including roof surface etc. complete as per design data, criteria, obligatory requirements and detailed specifications. Anti-termite treatment shall be given for underground portion of the structure.The design shall be in accordance with various relevant I.S. specification (I.S. 456/1978, I.S. 875 - 1987, I.S. 3370 -1965 or revised.Only M.S. bars grade I conforming to I.S. 432 part-I or high yield strength deformed bars conforming to I.S. 1786 or I.S. 1139 shall be used. Grade -II M.S. bars shall not be used.Entire structure shall be in M-300 only.The scope of pipe assembly work shall be upto 5 metre beyond outside face of the wall, cost of pipes valves and specials is not included in the rate but labour cost for laying and jointing is included.The G.S.R. / Sump above 15 lakh litres capacity shall be in two compartment.The Job includes designing the structure for uplift pressure and dewatering if required during entire execution and disposal of surplus excavated stuff within lead of 50 metres as directed by Engineer in-charge. If uplifts considered in design, then these rates shall be increased by 7.5%.G.S.R. outlets shall be with bell mouth of approved pattern in bottom slab and cost of designing bell mouth is included in the rate. Sump well includes cost of suction pit required at bottom.For pipe diameters upto 300 mm only CI pipes and CI specials shall be used. For pipe diameters above 300 mm, M.S. pipes and specials minimum 10 mm thick shall be used with proper anticorrosive epoxy treatment from inside and outside.Cost of pump house is not included in these rates.Above rates are applicable for Seismic Zones 2, 3 and 4.75% part rate shall be payable for reinforcement, concrete and plastering items of all types of G.S.R.s and sumps till satisfactory hydraulic testing for water tightness test is given and till that work shall be treated as incomplete.Note : Conditions from Sr. No. 1 to 11 shall form a part and parcel of tender and must be included in the draft tender papers for work of R.C.C. GSRs and sumps RCC GSR Capacity Cost of 25000 litre GRS Cost of Further 13000 @ 11.48 per liter Total cost of 38000 litre GSR 10% shall be added over the cost of GSR for sump where overhead pump house is proposed.MJP SSR Corrigendum No-8 (dt- 10-03-2022)
117ITEM NO.2 Providing ISI mark G.I. pipe of following class and dia. excluding GST levied by GOI & GOM in all respect, inspection charges, transportation to stores, etc. complete as per IS-1239/2004. Note : One coupler shall be provided with each full length of pipe cost of which is included in rates below. Inlet80 mm dia.GI.D./F pipes(heavy)
118Outlet 100 mm dia.GI.D./F pipes (heavy)
119Washout 80 mm dia.GI.D./F pipes (heavy)
120ITEM NO.3 Providing and supplying ISI standard D. I. specials & fitting with sealing rubber gasket of S.B.R,complete with cast iron follower gland and M.S. nut holts coated or otherwise protected from rusting and suitable for D.l.pipes including cost of labour, materials, and transpoffation to stores, loading and unloading excluding GST levied by GOI & GOM in allrespect etc. complete as per IS-9523. 80 mm to 300 mm dia (MJP SSR P No. 73 Section I(I) 4.iv/vi)
121ITEM NO.4 Providing double flange sluice valve confirming for IS- 14846 including worn gear arrangements as per test pressure, stainless steel spindle, caps, including inspection charges, transportation upto departmental store, unloading, stacking excluding GST levied by GOt & GOM in all respect etc. complete Sluice valves PN-1 without bye-pass arrangement 80 mm dia. Sluice valve - Inlet/Bypass
12280 mm dia. Sluice valve - Washout
123100 mm dia. Sluice valve - Washout (MJP SSR P No. 132 Section I(XII) 2a.iv)
124FHTC ITEM NO.1 Providing and making UPVC/MDPE pipe consumer service connection on Distribution main by drilling hole with suitable means , including all labour , UPVC/MDPE Pipe of required length with or without Road crossing as described below, including cost of specials like Saddle/Clamp Saddle of suitable material, and diameter suitable for Distribution main, 15mm /20mm/ 25mm respective Dia Heavy duty Brass/Polyprophylyne(Twin Jacketed ) Ferrule , Male and Female thread adapter Elbow, Bends,couplers ,Tees, Clamps of suitable material and sundry materials as per requirment, including providing and fixing medium duty 15.mm brass bib tap, GI casing pipe of suitable diameter of 32mm/ 40mm/ 50mm respectively of required length for Road crossing, including requird labour for excavation in all types of strata up to the depth of 0.75m or as per site requirement,all types of plumbing fittings, refilling , Closing the water supply in that area, dewatering, hydraulic testing and restarting the water supply ,transportation of material etc. complete as directed by Engineer in A) Household Connection without water meter (Comression Saddle+ISI Mark Ferrul) for HDPE & PVC pipe For MDPE/UPVC Pipe Service Connection on Disribution main (With Road Crossing)For 15 mm Service connection
125Without Road Crossing)For 15 mm Service connection

AI Tender Summary

OUR REF NO 32848738
AUTHORITY Government Departments
TENDER VALUE 64.91 Lakhs
LAST DATE 04-07-2022
Authority
Authority Name Rural Development Department
Work Description Newly Water Supply Scheme At Takli Tarfe Nandapur Tq. Hingoli Dist. Hingoli Under Jal Jeevan Mission (Jjm)
Basic Detail
Tender No Open/RWS/EE/jaljivan/09/22-23
Bidding Type Tender
Location
City nandapur
State Maharashtra
Key Dates
Publish Date 27 Jun 2022
Submission Date 04 Jul 2022
Open Date 06 Jul 2022
Finance
Tender Value 64.91 Lakhs
Tender Fee 5600
EMD 65000
Exemption Not Available
Document List
1e05360c-24c1-4172-af3c-f3d79851abed.html
B1Document.pdf
BOQ_1400819.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jun 27, 2022
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 04, 2022
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Jul 06, 2022

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

1e05360c-24c1-4172-af3c-f3d79851abed.html

pdf

B1Document.pdf

xls

BOQ_1400819.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders