| 1 | SubWork No.CONNECTING MAIN -Providing and supplying in standard lengths ISI mark rigid unplasticised PVC pipes suitable for potable water with solvent cement joints including cost of couplers, as per IS specification no. 4985 / 1988 excluding GST levied by GOI and GOM in all respect, including transportation, freightcharges, inspection charges, loading, unloading, conveyance to the departmental stores and stacking the same in closed shed duly protected from sun rays and rains including cost of jointing material i.e. solvent cement, etc. complete (selffit type to be jointed with cement solvent). 90mm 6kg |
| 2 | Providing and supplying in standard lengths ISI mark rigid unplasticised PVC pipes suitable for potable water with solvent cement joints including cost of couplers, as per IS specification no. 4985 / 1988 excluding GST levied by GOI and GOM in all respect, including transportation, freightcharges, inspection charges, loading, unloading, conveyance to the departmental stores and stacking the same in closed shed duly protected from sun rays and rains including cost of jointing material i.e. solvent cement, etc. complete (selffit type to be jointed with cement solvent). 75mm 4kg |
| 3 | Providing and supplying PVC/GI special suitabale for PVC pipes including cost of all taxes transformation to site of work, loading, unloading, stacking, etc. compd. |
| 4 | Providing ISI mark G.I. pipe of following class and dia. Including all local and central taxes, octroi, inspection charges, transportation to stores, etc. complete .as per IS 1239/2004 |
| 5 | Providing and supplying ISI mark CIDF sluice valves of following dia including all taxes (Central and local ) railway freight inspection charges ,unloading from railway wagon, loading into truck transportation upto departmental stores/sitesunloading stacking etc. complete. |
| 6 | Providing and supplying Air Valves as per IS 10845 and MJP\"s standard specifications of approved make and quality of following diameters including all taxes,freight,inspection charges,unloading and loading charges etc. complete. |
| 7 | Excavation for foundation /pipe trenches in earth, soils of all types, sand gravel and soft murum including removing the excavated material upto a distance of 50m and lift upto 1.5m, stacking and spreading as directed, drawing, shoring and strutting, preparing the bed for the foundation etc.complete. |
| 8 | Excavation for foundation/ pipe trenches in hard murum, including removing the excavated material up to dist.of 50M & lifts as below,stacking and spreeading as directed,normal Dewatering, preparing the bed for foundation & excluding backfilling,etc.complete. |
| 9 | Excavation for foundation / pipe trenches in soft rock and old cement and lime masonry foundation asphalt road including removing the excavated material upto a distance of 50 M beyond area and lifts as below, stacking as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. |
| 10 | Excavation for foundation/ pipe trenches in Hard Rock by controll blasting, including trimming and levelling the bed by chiselling where necessary and removing the excavated material and stacking it in measurable heaps within distance of 50 m. from the area and lifts as below, normal dewatering, excludung backfilling etc. compl. |
| 11 | Filling in plinth and floor murum bedding in trenches from excavated material from foundation 15 cm to 20cm layer including watering and compaction etc compld. |
| 12 | Lowering, laying and jointing with P.V.C. pipes and specials of following class and diameter including cost of conveyance from stores to site of works including cost of all labour, material, except cement solvent, rubber ring, giving satisfactory hydraulic testing as per IS code, etc. complete (with cement solvent joint / ring fit joint). |
| 13 | Lowering, laying and jointing with P.V.C. pipes and specials of following class and diameter including cost of conveyance from stores to site of works including cost of all labour, material, except cement solvent, rubber ring, giving satisfactory hydraulic testing as per IS code, etc. complete (with cement solvent joint / ring fit joint). |
| 14 | Lowering, laying and jointing G. I. pipes and specials of following class and diameter including conveyance from stores to site of works, all labour, giving satisfactory hydraulic test, etc. complete either underground or in vertical position, as directed by Engineer-in-charge. |
| 15 | Lowering, laying, jointing CIDF Reflux, Sluice, |
| 16 | Providing and laying in situ PCC M 150of trap/granite/quartzite/ gneiss metal forfoundation and bedding including normal dewatering,plywood form work, compaction, finishing and curing, etc, complete. |
| 17 | Providing, and fixing in position Air valve shaft including providing and fixing GI Medium Class or 6 mm thick M S pipe shaft 2.70 m long over branch flange of air valve tee, provinding PCC block of M 150 concrete 150 mm thick around the air valve teeincluding encasing of vertical shaft in PCC M 150 as shown in type design together with providing and making flanged joints wherever required and fixing of air valve over the shaft excluding cost of air valve and branch flanged air valve tee etc.complete as per type design and as directed by Engineer in charge for following diameters of pipe lines ( Type Design attached) |
| 18 | Refilling the trenches with available excavated stuff with soft material first over pipeline and then hard material in 15 cm.layers with all leads and lifts including consolidation,surcharging,etc.complete. |
| 19 | SubWork No. RCC ESR 40000 LIT-Designing (aesthetically) and construction RCC elevated service reservoirs of following capacity with RCC staging consisting of columns, internal and external bracing spaced vertically at not more than 4.5 meters centre to centre, including excavation in all types, of strata, foundation concrete, cement plaster water proofing compound to the inside face of the container, including refilling excavation pits/ trenches disposing of surplus excavated stuff within a load of 50 M, . including all labour & material charges including lowering , laying , errecting , hoisting and jointing of pipe assembly at inlet, outlet, washout , overflow & bypass arrangement as per design providing & fixing accessories such as M.S.Ladder for entering into container, C.I. manhole frame and cover as per requirement, water level indicator lightening conductor, G.I.pipe railing around RCC walkway at bottom of container and at top slab, |
| 20 | Providing and supplying I.S.I. standard CI double flanged pipes including all taxes (central & local ) Rly. Freights, insurance, unloading from railway, wagon,loading into truck, transport to sunloading, stacking etc. complete as directed 80mm |
| 21 | Providing double flange sluice valveconfirming for IS- 14846 including worn gear arrangements as per test pressure, stainless steel spindle, caps, including inspection charges, transportation upto departmentalstore, unloading, stacking excluding GST levied by GOI & GOM in all respect etc.complete 80mm |
| 22 | Providing & supplying ISI std. CI . D/F specials upto 150 mm dia. |