| 1 | DESCRIPTION OF ITEMS |
| 2 | Dismantling of MH / LED/ T-5/Gate/Garden lightfittingsof any capacityfrom existing poles / buildings of any height/type including re-fixing after repair/replacement of unserviceable parts such as LED drivers,LED modules T-5 tubes, chokes etc and making the fitting functional by replacing minor parts such as nuts,bolts PVC connector upto Rs. 25.00 each complete all as specified and directed. Notes:-Parts shall be measured & paid separately as given here-in-after as supply only. |
| 3 | Supply only cable twin core PVC insulated and unsheathed solid copper conductor of size 1.50 Sqmm complete all as specified and directed. |
| 4 | Supply only of Integral LED street light driver, enclosed with glass cover frame suitable for existing make/models of LED street light/flood lights of capacity 25/30 W complete all as specified and directed. |
| 5 | Supply only of Integral LED street light driver, enclosed with glass cover frame suitable for existing make models of LED street lights/flood lights having capacity 40/45/48/50 W complete all as specified and directed. |
| 6 | Supply only of Integral LED street light driver, enclosed with glass cover frame suitable for existing make/models of LED street light/flood lights of capacity 60/65/70/72/80/90 W complete all as specified and directed. |
| 7 | Supply only of Integral LED street light module with complete PCB and LED bulb suitable for 25/30 W LED street light for existing make and model complete all as specified and directed. |
| 8 | Supply only of Integral LED street light module with complete PCB and LED bulb suitable for 40/45/48/50 W LED street light/flood lights for existing make and model complete all as specified and directed. |
| 9 | Supply only of Integral LED street light module with complete PCB and LED bulb suitable for 60/65/70/72/80/90 W LED street light/flood lights for existing make and model complete all as specified and directed. |
| 10 | S&f in repairs Isolator 4 pole 63 Amps,415 Volts all as specified and directed. |
| 11 | S&f in repairs Isolator 4 pole 100 Amps,415 Volts all as specified and directed. |
| 12 | S&f in repairs Isolator 2 pole 40 Amps,220 Volts all as specified and directed. |
| 13 | S&f in repairs powder coated pressure die cast aluminium compact LED street light fitting heat resistance toughened glass with lens suitable for 30Watt complete all as specified & directed. |
| 14 | S&f in repairs powder coated pressure die cast aluminium compact LED street light fitting heat resistance toughened glass with lens suitable for 45 Watt complete all as specified & directed. |
| 15 | S&f in repairs powder coated pressure die cast aluminium compact LED street light fitting heat resistance toughened glass with lens suitable for 60 Watt complete all as specified & directed. |
| 16 | S&F in replacement new genration,post top energy saving environment friendly long life aesthetically designed with symmetrical light distribution LED gate light of capacity 60 watt with spun aluminium landscape luminaire with high power LED s as light source complete all as specified & directed. |
| 17 | S&F in replacement new genration,post top energy saving environment friendly long life aesthetically designed with symmetrical light distribution LED gate light of capacity 30 watt with spun aluminium landscape luminaire with high power LED s as light source complete all as specified & directed. |
| 18 | S&f in repairs powder coated pressure die cast aluminium compact LED flood light heat resistance toughened glass suitable for 70 Watt complete all as specified & directed. |
| 19 | S&f in repairs powder coated pressure die cast aluminium compact LED flood light heat resistance toughened glass suitable for 100 Watt complete all as specified & directed. |
| 20 | S&f in repairs LED Highbay Fitting 100 Watt with PDC aluminium housing with aim & adjustable bracket, Mat finished reflector for glare elimination, SMD LED with secondary lens & Integral SMD LED with pressure die cast aluminium housing, anodised aluminium reflector, complete with accessories IP-65 protection with necessary electrical connections alongwith iron chain suitable for bearing the load of fitting upto 1 mtrfor extension upto ceiling of any height complete all as specified & directed. |
| 21 | S & F in replacement of Integral LED aviation Light comprising of aluminium housing with poly carbonate enclosure complete all as specified & directed. |
| 22 | Supply and fix in repairs loop-in loop-out box of size 15x15x10 cm made of 1.6mm thick PVC sheet weather proof, dust and vermin proof with hinged door of locking arrangements and slanting cover on topwith provision of aluminium busbar of size 25 x 2mm - 2 No fixed on insulator complete fixed on pole with and including suitable size MS flat iron clamps, nuts, bolts and washers, etc complete all as specified & directed. |
| 23 | Supply and fix in repairs loop-in loop-out box of size 20x20x15 cm made of 1.6mm thick PVC sheet weather proof, dust and vermin proof with hinged door of locking arrangements and slanting cover on topwith provision of aluminium busbar of size 25 x 2mm - 4 No fixed on insulator complete fixed on pole with and including suitable size MS flat iron clamps, nuts, bolts and washers, etc complete all as specified & directed. |
| 24 | S&f in repairs street light bracket made out of 40 mm dia GI pipe light grade of length upto 1.5 mtr bent to shape required with and including 2 Nos, 50 x 6 mm MS flat iron clamps with nuts, bolts, washer etc and applying one coat of aluminium paint to clamps including dismantling of old brackets complete all as specified and directed. |
| 25 | S&f in repairs commissioning and testing of Naturetimer switch control StreetLights complete with MCB,Power and Panel duly complete with wiring Model : SWADEEP-02EC12KW 3P, single phase ,max load 12KW Manufactured by KAKATIYA ENERGY SYSTEMS LTD HYDERABADor equivalent of other make complete all as specified and directed.Note:- CA No & date of installations shall be painted/marked on all timer switch provided by the contractor |
| 26 | S&f in repairs commissioning and testing of Naturetimer switch control StreetLights complete with MCB,Power and Panel duly complete with wiring Model : SWADEEP-02EC8KW 1P, single phase ,max load 8KW Manufactured by KAKATIYA ENERGY SYSTEMS LTD HYDERABADor equivalent of other make complete all as specified and directed.Note:- CA No & date of installations shall be painted/marked on all timer switch provided by the contractor |
| 27 | S&f in repairs commissioning and testing of Digital Astrological timer street light control panel of Max load 12 KW complete with contractor rating 65/TP, MCB rating 63 Amp SPN with product code IHXSS0312A of Make Havellscomplete all as specified and directed.Note:- CA No & date of installations shall be painted/marked on all timer switch provided by the contractor |
| 28 | S&f in repairs commissioning and testing of Digital Astrological timer street light control panel of Max load 6 KW complete with contractor rating 32/TP, MCB rating 40 Amp SPN with product code IHXSS0106A of Make Havellscomplete all as specified and directed.Note:- CA No & date of installations shall be painted/marked on all timer switch provided by the contractor |
| 29 | S&F in replacement of 1100 Volts grade heavy duty cable one twin core, flat or circular 6 Sqmm PVC insulated aluminium stranded conductor served with inner sheathing of PVC tapes and overall PVC sheathed in service connection from pole to Main Switchcomplete all as specified and directed. |
| 30 | S&F in replacement of 1100 Volts grade heavy duty cable one twin core, flat or circular 10 Sqmm PVC insulated aluminium stranded conductor served with inner sheathing of PVC tapes and overall PVC sheathed in service connection from pole to Main Switchcomplete all as specified and directed. |
| 31 | S&F in repairs 1100 Volts grade heavy duty cable one twin core, flat or circular 16 Sqmm PVC insulated aluminium stranded conductor served with inner sheathing of PVC tapes and overall PVC sheathed in service connection from pole to Main Switchcomplete all as specified and directed. |
| 32 | Supply and fixing in replacement of Cable route markers made of galvanised iron with embossing of HT Cable or LT Cable, supporting MS angle of 75 cm long, for HT/LT cable route marking duly embedded in and incl PCC (1:3:6) foundation up to 30 cm incl excavation and earth work. |
| 33 | Lopping / pruning of tree branches upto the extend to obtain clearance all around the LT over head lines / HT over head linesconductor upto 3 mtr from furthest conductor on pole including removing of cut branches and cleaning of site complete all as specified and directed. Note :-(a). The trees branches etc will be left as it is and will not be carried away by the contractor / DEL as the wood belongs to CEO / DEO and they will be responsible to lift the wood. (b).pruning of all tree branches in one tree shall be measured as one Job.c).Contractor will employ sufficient labour to complete the job with in time as directed. (d).Contractor will be responsible for any type of mis-happening / accident while pruning the trees. (e).Contractor supervisor will take proper shut down from MES installation before starting the work and clear it before resuming power supply . However full assistance will be provided by MES staff. (f). The contractor will provide proper tools and safety devices to his staff for pruning of trees. |
| 34 | S&f in repairs micro prismatic reflective sheet, min 2.5 cm wide, with adhesive base for direct fixing on HT/LT steel tubular/PCC pole without nail or any other fixing material at suitable height, in Red/White/Yellow colour complete all as directed. |
| 35 | Supply & fixing in replacement shackle type porcelain vitreous white, brown or green insulator including onegalvanised mild steel straps, washers and nut 75 mm height, 90 mm dia for 1100 volts grade, including removal of existing insulators complete all as specified & directed. |
| 36 | Supply & fixing in replacement pin type porcelain vitreous white, brown or green insulator including onegalvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut 100 mm height, 65 mm dia for 1100 volts grade, including removal of existing insulators complete all as specified & directed. |
| 37 | Taking down of old aluminium conductor of any description /size from LT Poles including cross arms, bracing and other steel accessories complete all as specified & directed. |
| 38 | Refixing of ACSR conductor, removed under Item No 35 on existing or new LT poles including binding with 02 mm dia aluminium binding wire complete all as specified & directed. |
| 39 | S&f ACSR conductor of any size including binding on existing LT poles or new poles with 02 mm dia aluminium binding wire complete all as specified & directed. |
| 40 | Cleaning and preparation of old painted surface of LT/street light pole complete and painting with one coat of aluminium paint including channels/ brackets, street light brackets, cross arms and making red & white strips with synthetic enameled paint of 30 cm height, eachalternative strip upto 1.5 mtr height and writing pole numbers with yellow synthetic enameled paint after making circular basewith black synthetic enameled paint and applying two coats of white wash on PCC coping complete all as specified. |
| 41 | Material and labour for PCC 1:3:6 type C-2,using stone aggregate 40mm graded as in foundation of stays and coping of polesincluding necessary form work where required and fair finish to the exposed surfaces including demolition of existing PCC all as specified & directed. |
| 42 | Material and labour for PCC 1:4:8 type D-2, using stone aggregate 40mm graded as in foundation for electric poles and making of cable duct including necessary form work where required and fair finish to the exposed surfaces all as specified & directed. |
| 43 | Supply and erection (in truly vertical position) in replacement of LT Steel tublar swaged pole complete with cast iron base plate finial taper plug, bolt , nut and screwed type 410 SP 31 09 mtrs longClass -10 including painting of poles with two coats of synthetic enamel paint in red and white strips upto 1.5 mtr height from coping over a coat of red oxide primer including numbering of poles as directed by Engineer in charge.Note : PCC, Earth work and MS work as cross arms clamps etc will be measured and paid separately. |
| 44 | S&f in repairs cross arms (any type) supports, brackets, stiffners etc made out of MS channel, angle iron , flat iron of any size including drilling of holes, making clamps, eye hooks, nuts, bolts and washers etc, welding if required including painting with two coats of aluminium paint over a coat of red oxide paint as well as dismantling of existing complete all as specified & directed |
| 45 | Supplying, drawing and fixing in replacement of continuous GI earth wire/guard/cradles of 4mm dia including GI binding wire 1.63 mm and GI holding hook on HT poles incl taking down old rusted GI wire complete all as specified & directed. |
| 46 | M&L for in replacement of bus bar chamber, fixed on wall, 4 ways, 200 Amps ,415 V powder coated, water & vermin proof , IP-66 protection duly provided with front openable door incl provision of TPN copper bus bar heat shrinkable colored PVC sleeve coated for phase and neutralcomplete all as specified and directed. |
| 47 | M&L for in replacement of bus bar chamber, fixed on wall, 4 ways, 100 Amps ,415 V powder coated, water & vermin proof , IP-66 protection duly provided with front openable door incl provision of TPN copper bus bar heat shrinkable colored PVC sleeve coated for phase and neutralcomplete all as specified and directed. |
| 48 | M&L for in replacement of bus bar chamber, fixed on wall, 4 ways, 63 Amps ,415 V powder coated, water & vermin proof , IP-66 protection duly provided with front openable door incl provision of TPN copper bus bar heat shrinkable colored PVC sleeve coated for phase and neutralcomplete all as specified and directed. |
| 49 | M&L taking out old earthing and providing eearthingcomplete with galvanised or steel earth plate electrode of size 60cm x60cmx6mm thick buried directly in ground vertically ( to a depth not less than 2.25mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected tostrip 32x 6 mm size with nuts, bolts , check nuts , washers, earth plate surrounded by packed layers of charcoal dust and common salt 15cm thick all around, top & bottom watering pipe 20mm bore of GI mediumgrade with funnel and wiremesh all as shown in electrical plate No. 5 of SSR -1991 Part I and connecting to earthingtest point,main switch board and testing oncompletion including PCC chamber concrete 1:3:6 typeC-2 and RCC cover 75mm thick with MS TMT bar 8mm dia @ 150mm c/c both ways in cement concrete(1:2:4) type B-1 all asshown in electrical plate in No 5 of SSR(Pt-I)1991 complete all as specified & directed. |
| 50 | S&f in repairs galvanized iron strip of size 32x6 mm as earth continuity conductor provided in between earth test point terminal and upto the equipment incl nuts, bolts and washers complete all as specified and directed. |
| 51 | Supply and fixing in replacement of danger notice plate of 1.6mm thick, MS sheet, vitreous enameled white, with letters, figuresand conventional skull and bones in signal red colour and fixed with MS clamps made out offlat iron 25x3 mm, nuts-bolts, of approved size for LT 20 x 15 cm complete all as specified & directed. |
| 52 | S&f in repairs PVC LT OH line spacer for 5 wires complete all as specified and directed. |
| 53 | S&f in repairs PVC LT OH line spacer for 4 wires complete all as specified and directed. |
| 54 | S&f in repairs PVC LT OH line spacer for 2 wires complete all as specified and directed. |
| 55 | Dismantling of existing change over switch including disconnection and connection of LT cable complete and supply fixing of offload change over switch of capacity 100 Amp TPN with enclosure box including handle and other accessories complete all as specified & directed. |
| 56 | Dismantling of existing change over switch including disconnection and connection of LT cable complete and supply fixing of offload change over switch of capacity 200 Amp TPN with enclosure box including handle and other accessories complete all as specified & directed. |
| 57 | S&F contactor MNX 40 of existing make/model suitable for street light timer including dismantling existing un serviceable from the timer assembly and making reconnection connectioncomplete all as specified & directed. |
| 58 | S&F timer digital type suitable for street light timer including dismantling existing un serviceable from the timer assembly and making reconnection connectioncomplete all as specified & directed. |
| 59 | S&f in repairs heat shrink LT end joints of size 6 sqmm to 16 sqmm complete all as specified & directed. |
| 60 | S&f in repairs heat shrink LT end joints of size 25 sqmm to 50 sqmm complete all as specified & directed. |
| 61 | S&f in repairs heat shrink LT end joints of size 70 sqmm to 95 sqmm complete all as specified & directed. |
| 62 | S&f in repairs heat shrink LT end joints of size 120 sqmm to 150 sqmm complete all as specified & directed. |
| 63 | S&f in repairs heat shrink LT end joints of size 185 sqmm to 240 sqmm complete all as specified & directed. |
| 64 | S&f in repairs heat shrink LT end joints of size 300 sqmm to 400 sqmm complete all as specified & directed. |
| 65 | S&F stay assembly (in replacement) consisting of galvanisedstaywire 7/10 SWG stay bow of 14 mm dia, stay rod 16 mm dia 180 cm long with loop insulators stayplate 230 x 230 mm x 6 mm with PCC foundation 1:3:6 type C2 complete with stay clamps, bolts and nuts all as specifiedand directed including the following :-.(a) Excavationand earth work for stay foundation in soft/loose soil,disposal of surplussoiltoa distance n exc 50 metres &depositingwhere directed at a level n.exc 1.5 mtr from the starting point as directed.(b) PCC1:3:6, typeC-2 ( using 40 mm gradedstoneaggregate ) as in embedding blocks all as specified. |
| 66 | M&L taking out old earthing and providing eearthingcomplete with galvanised or steel earth plate electrode of size 60cm x60cmx6mm thick buried directly in ground vertically ( to a depth not less than 2.25mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to wire of 4 mm dia by means of nuts, bolts , check nuts , washers, earth plate surrounded by packed layers of charcoal dust and common salt 15cm thick all around, top & bottom watering pipe 20mm bore of GI mediumgrade with funnel and wiremesh all as shown in electrical plate No. 5 of SSR -1991 Part I and connecting to earthingtest point,main switch board and testing oncompletion including PCC chamber concrete 1:3:6 typeC-2 and RCC cover 75mm thick with MS TMT bar 8mm dia @ 150mm c/c both ways in cement concrete(1:2:4) type B-1 all asshown in electrical plate in No 5 of SSR(Pt-I)1991 complete all as specified anddirected. |
| 67 | Excavation in trenches in any type of soil n.exc. 1.5 mtr wide and n.exc1.5 mtr in depth forLT cables complete including bricks all as specified & directed. |
| 68 | Returning, filling in, any type of soil and spreading in layers n. exc 25cm thick each layer including watering & well ramming complete all as specified & directed. |
| 69 | Removal of surplus soil to a distance n.exc 50 mtr & depositing where directed at a level n. exc. 1.5mtr above the starting point complete all as specified & directed. |
| 70 | Supply and laying in replacement XLPE insulated , armoured heavy duty electric cable with alumnium conductor ,1100 volts grade ,corss sectional area 6 sqmm 4 core complete all as specified and directed. |
| 71 | Ditto Ditto all as per ser item No. 69 here-in-before but 10 Sqmm 2 core |
| 72 | Ditto Ditto all as per ser item No. 69 here-in-before but 10 Sqmm 4 core |
| 73 | Ditto all as per ser item No. 69 here-in-before but 16 Sqmm 4 core |
| 74 | Ditto all as per ser item No. 69 here-in-before but 25 Sqmm 4 core |
| 75 | Ditto all as per ser item No. 69 here-in-before but 35 Sqmm 3½ core |
| 76 | Ditto all as per ser item No. 69 here-in-before but 50 Sqmm 3½ core |
| 77 | Ditto all as per ser item No.69 here-in-before but 70 Sqmm 3½ core |
| 78 | Ditto all as per ser item No. 69 here-in-before but 95 Sqmm 3½ core |
| 79 | Ditto all as per ser item No. 69 here-in-before but 120 Sqmm 3½ core. |
| 80 | Ditto all as per ser item No. 69 here-in-before but 150 Sqmm 3½ core. |
| 81 | Ditto all as per ser item No. 69 here-in-before but 185 Sqmm 3½ core. |
| 82 | Ditto all as per ser item No. 69 here-in-before but 240 Sqmm 3½ core. |
| 83 | Ditto all as per ser item No. 69 here-in-before but 300 Sqmm 3½ core. |
| 84 | M & L for brick protection to cable using old size sub class \"B\"bricks, laid flat, dry butt jointed, laid lengthwise perpendicular to the axis of cable all as specified & directed. |
| 85 | Ditto all as per ser item No 83 here-in-before but using old bricks obtained by taking out under respective items. |
| 86 | M&L forsand cushioning with layer of sand 8 cm thick before laying of cable and 15 cm after lying of cablein trenches complete all as specified & directed. |
| 87 | Cutting of floor/wall/road/footpath for removal of LT U/G cable of any size/description and making good the same as per existing specification after relaying the same or new cable and all as specified & directed. |
| 88 | S & F in replacementGI pipe light grade 80mm bore for cable protection, fixed to pole/ alongwall/ floor/ under road/ across the drain or nallahetc complete all as specified & directed. |
| 89 | Ditto all as per ser item No.87 here-in-before but 50mm bore. |
| 90 | Ditto all as per ser item No.87 here-in-before but 40mm bore. |
| 91 | Supply, installation, commissioning and testing in replacementpowdercoated factory made panel board outdoor type confirming to IP 64 protection, of suitable size made of Robust steel sheet construction made from min 3.15 mm steel sheet with countersunk holes at bottom for base mounting brackets and sheet steel gland plates for cable entry, formed gasket around doors, with provision of Lock inserts, earthing straps, door stay and grouted in ground by using angle iron frame of size 50mm x 50mm x 6mm, PCC (1:2:4) type C-1 with 20mm graded stone aggregate.The panel will be prewired with suitable size PVC insulated copper conductor cable, multistranded housed with the following accessories complete all as specified & directed:- (a) Aluminium bus bar of capacity 300 Amp for phase and 150 Amps for neutral.(b) Incoming MCCB 4 pole 160 Amp 25 KA alongwith Spreader terminals with adjustable thermal setting ( ICS= 100% ICU)– 01 Nos(c) Outgoing MCCB 4 pole 63 Amp 25KA alongwith Spreader terminals with adjustable thermal setting ( ICS= 100% ICU)– 02 Nos.(d) On load change over switch of capacity 100 Amp– 01 Nos(e)Digital volt meter 0 to 500 volt with selector switch – 01 No(f)Digital Amp meter 0 to 400 Amp with CT of suitable ratio and selector switch – 01 No(g) Phase Indicator Lamp RYB with sheds LED Type - 01 Set of three(r) Digital timer switch (Astronomical) along with contractor/MCB and suitable accessories. |
| 92 | S&f in repair MS busbar chamber of nominal dimension 900 mm x 600 mm x 300 mm duly provided with aluminimum busbar of size 50 mm x 6mm fixed on porcelain insulators TPN type out door weather/vermin proof with both way opening duly provided with neoprene rubber gasket along the doors openings pedestal type duly painted powder coated on CRCA steel sheet encloser with one No incomer MCCB 200 Amp 25 KA complete all as specifiedand directed incl making connection /thimbles etc complete all as specified & directed. |
| 93 | Ditto all as per srl item No 91 here-in-before but of size 600 mm x 600 mm x 300 mm and without MCCB |
| 94 | S&f in repairs MS busbar chamber of nominal dimension 900 mm x 600 mm x 300 mm duly provided with aluminimum busbar of size 50 mm x 6mm fixed on porcelain insulators TPN type out door weather/vermin proof with both way open ing duly provided with neoprene rubber gasket along the doors openings pedestal type duly painted powder coated on CRCA steel sheet encloser with one No incomer MCCB 100 Amp 25 KA complete all as specifiedand directed incl making connection /thimbles etc complete all as specified & directed. |
| 95 | S & F in replacement MCCB 415 Volts 4 pole 500 Amps 50 Hz 36 KA of existing make model and typealonwith spreader terminal with adjustable thermal settingincluding lugs/thimbles of suitable size in existing panels complete all as specified and directed. Note : Necessary addition /alterationrequired to adjust MCCB in the panel shall be done by the contractor and no extra payment will be made to the contractor. |
| 96 | Ditto all as per ser item No.94 above but of MCCB 400 Amps 4 pole 50 Hz 415 V with rupturing capacity 36 KA |
| 97 | Ditto all as per ser item No.94 above but ofMCCB 315 Amps 4 pole 50 Hz 415 V with rupturing capacity 36 KA |
| 98 | Ditto all as per ser item No.94 above but ofMCCB 250 Amps 4 pole 50 Hz 415 V with rupturing capacity 25 KA |
| 99 | Ditto all as per ser item No.94 above but ofMCCB 200 Amps 4 pole 50 Hz 415 V with rupturing capacity 25 KA |
| 100 | Ditto all as per ser item No.94 above but ofMCCB 100 Amps 4 pole 50 Hz 415 V with rupturing capacity 25 KA |
| 101 | Ditto all as per ser item No.94 above but ofMCCB 63 Amps 4 pole 50 Hz 415 V with rupturing capacity 16 KA |
| 102 | S & F in replacement MCCB 415 Volts 3 pole 350 Amps 50 Hz 36 KA of existing make model and typealonwith spreader terminal with adjustable thermal settingincluding lugs/thimbles of suitable size in existing panels complete all as specified and directed. Note : Necessary addition /alterationrequired to adjust MCCB in the panel shall be done by the contractor and no extra payment will be made to the contractor. |
| 103 | Ditto all as per ser item No.101 above but ofMCCB 250 Amps 3 pole 50 Hz 415 V with rupturing capacity 36 KA |
| 104 | Ditto all as per ser item No.101 above but ofMCCB 200 Amps 3 pole 50 Hz 415 V with rupturing capacity 36 KA |
| 105 | Ditto all as per ser item No.101 above but ofMCCB 160 Amps 3 pole 50 Hz 415 V with rupturing capacity 36 KA |
| 106 | Ditto all as per ser item No.101 above but ofMCCB 100 Amps 3 pole 50 Hz 415 V with rupturing capacity 16 KA |
| 107 | Clearing away all grass vegetation ,saplings, shrubs, brush wood undergrowth roots and trees not exceeding 30 CM girth (measured one metre above ground level) and removing rubbish upto a distance of 50 metres outside the periphery of the area under clearancesoft/loose soiland getting outincluding spreading of anti vegetation chemical on complete Area complete all as specified & directed. |
| 108 | S&f in repairs testing and commissioning of epoxy type straight through jointing kit suitable for LT cable of size 10 Sqmm to 70 Sqmm, 3.5 to 4 core, XLPE insulated, PVC sheathed armoured 1100 volts grade complete all as specified & directed. |
| 109 | Ditto all as per ser item No 107 here-in-before but 95 to 120 Sqmm. |
| 110 | Ditto all as per ser item No 107 here-in-before but 150 to 185 Sqmm. |
| 111 | S&f in repairs LT PVC tape roll 3/4 inch size ISI marked on Panels/Transformers LT side complete all as specified & directed. |
| 112 | S& F in replacement ofAluminium Lugs/connectors of size 16 sqmm complete all as specified & directed. |
| 113 | S& F in replacement of Aluminium Lugs/connectors of size 25 sqmm complete all as specified & directed. |
| 114 | S& F in replacement of Aluminium Lugs/connectors of size 35 sqmm complete all as specified & directed. |
| 115 | S& F in replacement of Aluminium Lugs/connectors of size 50 sqmm complete all as specified & directed. |
| 116 | S& F in replacement of Aluminium Lugs/connectors of size 70 sqmm complete all as specified & directed. |
| 117 | S& F in replacement of Aluminium Lugs/connectors of size 95 sqmm complete all as specified & directed. |
| 118 | S& F in replacement of Aluminium Lugs/connectors of size 120 sqmm complete all as specified & directed. |
| 119 | S& F in replacement of Aluminium Lugs/connectors of size 150 sqmm complete all as specified & directed. |
| 120 | S& F in replacement of Aluminium Lugs/connectors of size 185 sqmm complete all as specified & directed. |
| 121 | S& F in replacement of Aluminium Lugs/connectors of size 240 sqmm complete all as specified & directed. |
| 122 | S& F in replacement of Aluminium Lugs/connectors of size 300 sqmm complete all as specified & directed. |