Round The Clock Maintenance Of Tg And Its Aux. Of Unit 1, 2 And 3 Of 3X210 Mw, Atps, Anpara
Tender Value
36.36 Lakhs
Estimated cost
Bid Submission
01 Aug 2022
0 days left
EMD
60000
Bank guarantee accepted
Document Fee
1180
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
anpara → Uttar Pradesh
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Round The Clock Maintenance Of Tg And Its Aux. Of Unit 1, 2 And 3 Of 3X210 Mw, Atps, Anpara
BOQ
| Sl. No. | Item Description |
| 1 | Round the clock up-keeping and maintenance of Turbine and its auxiliaries as per scope of work of Tender specification. (One Job means round the clock i.e. in all three shifts per day for one month) |
| 2 | 1- For Anpara 210MW Unit-1 |
| 3 | 2- For Anpara 210MW Unit-2 |
| 4 | 3- For Anpara 210MW Unit-3 |
| 5 | Overhauling of Centrifuging machine MAB103/206 as per scope of work. |
| 6 | Oil Flushing of H.P. Bypass oil system as per scope of work. |
| 7 | Maintenance of EOT Crane (2 nos.) as per scope of work. |
| 8 | Transportation of lubricant/spares/consumables |
| 9 | Transportation of lubricant from Central Store to Site store. |
| 10 | Transportation of Empty Drums from site store to Central Store. |
| 11 | Running and up-keeping of 2 nos. portable centrifuging machine as per scope of work. |
| 12 | Replacement of the damaged L.P. diaphragms. |
| 13 | Cleaning of suction strainer of CEP |
| 14 | Cleaning of strainers of Raw Water Booster pumps |
| 15 | Round the clock up-keeping and maintenance of Boiler Feed Pumps and Condensate pumps as per Scope of work of tender Specification. .(One Job means round the clock i.e. in all three shifts per day for one month) |
| 16 | For Anpara 210MW Unit-1 |
| 17 | For Anpara 210MW Unit-2 |
| 18 | For Anpara 210MW Unit-3 |
| 19 | Replacement of Old Turbine Oil cooler tube Nest Assembly with new one and installation and commissioning the same in unit#1/2/3 of 3x210 MW, ‘A’TPS, Anpara |
| 20 | Cleaning of Main oil tank room and spreading fresh sand (As per attached annexures) |
| 21 | Cleaning of Main Oil tank |
| 22 | Overhauling of gland seal vapour exhauster /Oil extraction fan |
| 23 | Replacement of damaged N2 gas bladder from Accumulator of HP Bypass system |
| 24 | Replacement of compensator of hotwell/ condensate Extraction pump |
| 25 | Cleaning of C.W. Duct inside the T.G. hall |
| 26 | Checking of through ness of drainpipe of Main Steam and hot reheat strainer |
| 27 | Repairing work of grating/chequred plate |
| 28 | Attending tube leakage of H. P. Heaters 5/6 of 3x210MW and commissioning of Heaters from water and steam side. |
| 29 | Attending water leakage from water box cover of H. P. Heaters 5/6. |
| 30 | Servicing of Pneumatically operated recirculation valves of BFP Nb 100mm |
| 31 | Servicing of solenoid operated drain valves DW-109 / DW-110 |
| 32 | Servicing of motorized extraction valve ES-I / ES-4 Nb 200mm |
| 33 | Servicing of motorized Feed water discharge valves of BFP BF -7/8/9 of Nb200mm. |
| 34 | Servicing of H.P. motorized drain valve 25 to 50mm |
| 35 | Servicing of HP Manual valves & NRVs |
| 36 | Servicing of pneumatically operated drip line valve of LP heater, MC-23/19 ,DM-15 /16 |
| 37 | Servicing of LP Hand operated/motorized valves at different elevations 25mm to 150mm. |
| 38 | Servicing of L.P. Hand operated/motorized valve/NRVs Nb 200mm to 500mm |
| 39 | Replacement of LP Valves (flange type) 100 to 500mm |
| 40 | Servicing of self-actuating feed water group protection valves FW-55/56 of H.P. Heaters of Nb-250mm and Np-250 Kg/cm². |
| 41 | Servicing of feed water motorized isolating valves of HP Heaters Nb 300mm. |
| 42 | Servicing & overhauling of Actuators K-150, F16A |
| 43 | Servicing of actuators type K-600, F14E |
| 44 | Servicing of pneumatic actuators |
| 45 | Servicing/Overhauling of Main Ejectors |
| 46 | Overhauling & Rectification of tube leakage from Turbine oil Coolers. |
| 47 | Overhauling/servicing of L. P. Heaters. |
| 48 | Servicing of drip control valves of H. P. Heater HD-20, HD-23, HD-14 |
| 49 | Changing gaskets of flanges in feed line heaters, ejectors, Drain coolers etc. |
| 50 | Servicing of Actuators Limitorque/Siemens/ Acuma make |
| 51 | Replacement of HP valves steam line, oil line(motorized/hand operated) at different floors from (-) 4 meter to 11 meter level size up to Nb 25mm |
| 52 | Replacement of HP valves steam line, oil line(motorized/hand operated) at different floors from (-) 4 meter to 11 meter level size above 25mm and up to Nb 100mm |
| 53 | Replacement of gland packing of HP valves from Nb 50mm to Nb 500mm. |
| 54 | Replacement of gland packing of HP Bypass valve (BP-1 / BP-2). |
| 55 | Servicing of actuators of turbine gland seal steam /leak off controller along with valve. |
| 56 | Servicing of Electro hydraulically operated HP By pass valve (BP-1 / BP-2) |
| 57 | Attending leakages of pipeline & headers etc.of Turbine And It’s Auxiliaries by cutting grinding and H.P. welding of damaged portion putting new spools/bends if required. |
| 58 | Replacement of H.P. drain pipes of size upto Nb-60mm, Thickness-10mm, Material- Carbon/Alloy Steel |
| 59 | Replacement up to three joints shall be considered as one job |
| 60 | Rate per joints beyondthree joints(beyond Sl No 50.2) |
| 61 | Complete spray insulation and repair of spray insulation on following equipments including supply of self setting cement compound, spray wool alkali silicate binder retainers, M. S. Plate, aluminum shields, S.S. and G.I. wire nettings, removal of old and damaged insulation re-fixing of end shields plastering and finishing as per BHEL norms and specifications.1. H. P. casing 324 to 360 mm insulation thickness.2. Interceptor valves and I.P. control Valves 270mm thickness insulation. All the above equipments including their end shield on front and rear sides and other areas as per site requirements. |
| 62 | Supply and application of thermal insulation on critical steam pipes such as main steam hot reheat, cold reheat, cross around and feed cycles pipes etc. including fixing and fitting of protective covering insulation thickness 50mm silicate and 100mm mineral wool or by 180mm thickness of lightly resin bonded mineral/ rock wool and sheetings. |
AI Tender Summary
Tender Timeline
Jun 25, 2022
11:30 IST
Tender Published
Tender notice published.
CompletedAug 01, 2022
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedAug 02, 2022
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender