Various Civil Work And Repairing Work In Sub Div I Of Div.-Ii-A Area. ( Arc ) Civil Works Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on p, kota-Rajasthan

Urban Improvement Trust-UIT has published Various Civil Work And Repairing Work In Sub Div I Of Div.-Ii-A Area. ( Arc ) Civil Works Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on p. Submission Date for this Tender is 11-07-2022. Uniform Tenders in kota Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

32830880
Various Civil Work And Repairing Work In Sub Div I Of Div.-Ii-A Area. ( Arc ) Civil Works Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on p
Open Tender
Indian
Rajasthan
kota
11-07-2022

Tender Details

Various Civil Work And Repairing Work In Sub Div I Of Div.-Ii-A Area. ( Arc ) Civil Works Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed with in a lead of 50 meter.All kinds of soils 2 Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30cm in depth. 1.5m in width as well as 10 sqm on plan) including disposal ofexcavated earth, lead upto 50m andlift upto 1.5 m , disposed earth to be levelled and neatly dressed: All kinds of soil 3 Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. M10 grade Nominal Mix 1: 3: 6 (1 cement : 3 coarse sand : 6 graded stoneaggregate 20mm nominal size). 4 Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level.M20 grade Nominal Mix1: 1.5: 3 (1 cement : 1.5 coarse sand : 3 graded stoneaggregate 20mm nominal size). 5 Random Rubble stone masonry for with hard stone in foundation and plinth in Cement Sand mortar above 30 CM thick wall in:Cement Mortar 1:6 ( 1-Cement : 6-Sand). 6 Providing and laying damp-proof course with cement concrete grade M-150 (1 : 2 : 4) mortar prepared with 1% solution of water-proof compound complete as per specification . 50mm thick. 7 Plaster on new surface on walls in cement sand mortar 1:6 including racking of joint etc. complete fine finish : 20mm thick. 8 Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry, making of lines or groove etc complete but excluding the cost of nosing of steps etc. complete. 50mmthickwith20mmthicknominalsizeaggregate. 9 Centering and Shuttering with plywood or steel plate including strutting, propping bracing both ways and removal of formwork for foundation , footings,strap beam, raft , bases of columns etc. 10 Providing and laying in position specified grade ofcement concrete forall RCC structural elements upto plinth level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement. M20 grade Nominal Mix 11 Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor Three level. 12 M-40,80mm thick to be used in medium-traffic (Medium trafficis defind as a daily traffic of 150-450 commercial vehicles exceeding 30 KN laden weight , or an equivalent of 0.5 to 2.0 MSA for a design life of 20years) like city streets, small and medium market roads, low volume roads ,ytility cuts on arterial roads, etc. Category Bdenated only two side like I,Z,T shape etc. as per IRC SP 63:2004 13 Add extra over rates of 1A to E, if colored paver blocks are used 14 Supply & Stacking good soil of earth at site complete including loading unloading & Transportation etc. Good soil of earth 15 Spreading of manure and good earth in required thickness (cost of manure and good earth to be paid separately). 16 S & FCC 1:2:4 (M15) Precast kerb on dand upto 60 cm length over 20 mm thick base of cement mortar 1:6 including jointing, earthwork, painting and jointing with cement mortar 1:4 of size.15 × 40 cm 17 Polished Blue Kota stone flooring skirting, laid over 20 mm thick base of C.M. 1 : 4 and jointed with grey cement slurry to match the shade of the slab including rubbing and polishing complete :For area of each slab from 2001 to 5000 Sq.Cm : 25 mm thick slab. 18 Rough chisel dressed stone flooring over 20 mm (Av.) thick base in CM 1 : 6 including pointing with cement mortar 1 : 2 (1 cement : 2 stone dust) with and admixture of pigment to match the shade of stone with joint thickness upto 15 mm : 35 mm thick red sand stone. 19 Providing and fixing steel gate, grating , and grills made of angles, tees, square bars, flats,or black pipe with holdfast and fittings complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide 20 Add extra if square, rectangular hollow tubular sections are used. 21 Painting with synthetic enamel paint of approved brand and manufacture togive an even shade : Two or more coats on new work 22 Painting with synthetic enamel paint of approved brand and manufacture togive an even shade : One or more coats on old work. 23 Finishing wall with water proofing cement paint of approved brand and manufacture and or required shadetogive an even shade including all scaffolding: On new surface. 24 Finishing wall with water proofing cement paint of approved brand and manufacture and or required shadetogive an even shade including all scaffolding: On old surface. 25 Providing stone slab covering over drains including filling of joints in cement sand mortar 1 : 3 with 35 mm thick cement concrete flooring 1 : 2 : 4 mix complete with good finish with : Stone slab 40 to 50 mm thick average. 26 Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. M20 grade Nominal Mix1: 1.5: 3 (1 cement : 1.5 coarse sand : 3 graded stoneaggregate 20mm nominal size). 27 Flyash Brick masonry with Flyash Bricks of class designation 75infoundation and plinth. Cement mortar 1 : 6 (1 cement : 6 coarse sand) 28 Flyash Flyash Brick work with flyash Flyash Bricks of class designation 75 in superstructure above plinth level upto floor Three Level in all shapes and sizes in :Cement mortar 1 : 6 (1 cement : 6 coarse sand) 29 Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard jointed with neat cement slurry mixed with pigment to match the shade of tiles includingrubbing and cleaning etc. complete on 20 mm thick bed of cement mortar 1:4 (1 cement : 4 coarse sand) Light shade using shade cement. 30 P&F rigid PVC Pipe (IS:4985 mark) class II/ (4 Kg. /Cm2.) approved quality /makeincluding joining the pipe with solvent cement rubber ring and lubricant. 110 mm dia 31 Providing and laying Reinforced cement concrete pipes NP-3 for culverts including jointing ends and fixing collar with cement mortar 1:2. (MoRTH specification : clause 1000/2900). 32 300 mm dia 33 600 mm dia 34 Providing and fixing 15 to 20 mm thick Granite stone slab mirror polished and machine edge cut in walls, pillars, steps, Shelves, Sills Counters, Floors etc. laid on 12 mm (Av.) thick base of cement mortar 1 : 3 (1 cement : 3 coarse sand) jointing with white cement mortar 1 : 2 (1 white cement : 2 marble dust) with pigment to match the shade of the granite slab complete including rubbing and polishing of :Jhansi (Red/Chocolate colour) Above 3601 cm2 slabs 35 Transportation of excavated of earth from site including loading unloading etc. complete with all lead and lift. Lead upto 5 Km. 36 Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade : Two or more coats on new work including preparation of base with primer, putty, lippy complete in all respect. 37 Painting exterior surface ofWallwith 100% acrylic exterior paint of approved brand and manufacture to give an even shade with two or more coats including prepartion of base with sand papering, primer, putty,etc complete in all respect. New Work 38 Providing and applying white cement based puttyover plastered surface to prepare the surface even and smooth complete 39 Providing, laying and spreading of granular sub-base by providing coarse graded Material, spreading in uniform layers with motor grader on prepared surface mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per MoRTH Specification : clause No. 401. Grading-III 40 P & F Stone cladding / Flooring works dressed bansi paharpur stone 25mm thick in traditional style used in cladding/Flooring with pattern over 25 to 50 mm thick base in CM 1:6 including pointing with cement mortar 1:2 (cement : 2 stone dust) matche the shade of stone with joint thickness upto 1.5mm as per direction of engineer-in-charge. 41 Single piece of stone element with carving work in Bansi Paharpur stone includes stone pillar, stone base, todies and thabi etc carving work as per direction of engineer in charge 42 Providing and fixing 1st quality standard white, grey, ivory, fume red brown, light green, light blue and other light shades glazed tiles confirming to IS : 13753 & IS :15622 of size 300mm x 450mm in walls, floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (excluding the cost of cement plaster on walls and pillar). 43 Providing and fixing 1st quality MAT finished ceremic tile size 300x300mm confirmingto IS : 13755 and IS : 15622 colour such as white, grey, ivory, fume red brown, light green, light blue and other light shades in floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (including the cost of cement mortar bed 1:4). 44 P/Laying P.V.C./ XLPE insulated & P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor of IS:1554 P-I / IS :7098 P - I of Group 1 of approved makein ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick underlayer ofsand,IInd class bricks covering, refilling earth,compaction of earth, making necessary connection, testing etc. as required of size. 4.0 Sq.mm 4 core 45 P/Laying P.V.C./ XLPE insulated & P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor of IS:1554 P-I / IS :7098 P - I of Group 1 of approved makein ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick underlayer ofsand,IInd class bricks covering, refilling earth,compaction of earth, making necessary connection, testing etc. as required of size. 6.0 Sq.mm 4 core 46 P&F strip type fluorescent tube fitting fabricated from (CRCA) sheet and finished with powder coating/stove enamelled paint/ (extruded non corrosive UV resist EP channel) complete with accessories like (OCCB, starter, starter seat) / EB, rotor holder, terminal block duly prewired with copper conductor including making connection, testing etc. as required. (without tube) 1×36 watts with OCCB, Group-I 47 P&F fluorescent tube rod in existing fixtures as required. Fluorescent powder coated 36/40 watts, Group-II 48 P & F double ball bearing capacitor start, aluminium body & blade ceilingfanwith down rod up to 30 cm with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required.1200 mm sweep.Group-I 49 Providing and fixingaluminum workfor doors ,windows, ventilators and partition with extruded built up standard tubular / appropriate Z sections and other sections of approved make conforming to IS :733 and IS :1285,fixed with rawl plugs and screws or with fixing clips ,or with expansion hold fasteners including necessary filling up of gap. at junctions , at top ,bottom and sides with required PVC/neoprene felt etc. Aluminium section shall be smooth ,rust free, straight ,mitered and jointed mechanically wherever required including cleat angle Aluminium snap beading for glazing /paneling , C.P. brass/ stainless steel screws Al. Tower bolt & Al. handle & Al. Aldrop etc.,all complete as per architectural drawings and thedirections of Engineer- in – charge .(Glazing and paneling to be paid for separately). Anodised aluminum (anodised transparent 81 dyed to required shade according to IS : 1868. (Minimum anodic coating of grade AC 15, Anodizing to be got done from approved Anodizer) For fixed portion 50 For shutters builtup standard tubular sections of openable doors ,windows & ventilators including providing & fixing hinges / rollers etc. and making provision for fixing of fittings wherever required (lockes shall be paid for separately). Anodised aluminum (anodised transparent 81 dyed to required shade according to IS : 1868. (Minimum anodic coating of grade AC 15, Anodizing to be got done from approved Anodizer) 51 Providing and fixing 12 mm thick prelaminated three layer medium density (exterior grade ) particle board Grade I, Type II conforming to IS : 12823 bonded formaldehyde synthetic resin ,of approved brand and manufacture in paneling fixed in aluminium doors ,windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and direction of engineer-in-charge. Prelaminated particle board with decorative lamination on both sides. 52 Providing and fixing glazing in aluminium door, window ,ventilator shutters and partitions etc. with PVS / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge.(Cost of aluminium snap beading shall be paid in basicitem.) With glass panes of 4.0 mm thickness ( weight not less than 10.0 kg/sqm) as per IS : 2835. 53 Providing and fixing expanded grill made of aluminum as per design and drawing having members section of size 7.5mm x 6.0mm and opening of size 102mm x 99mm to aluminum window/vent with required screws, Y and H aluminium sec (as per drawing) at the ends and middle joints respectively complete in all respect as per direction of engineer in charge. Anodised aluminum (anodised transparent 81 dyed to required shade according to IS : 1868. (Minimum anodic coating of grade AC 15, Anodizing to be got done from approved Anodizer) 54 Providing and fixing external grade board solid core single leaf flush door shutters ISI 2202-67 marked using Phenol formal dehyderesinin glue both sides with approved steel fittings complete as per annexure A:30 mm thick commercial Veneer Both side 55 Providing& fixing door, window, chowkhats and other frames, including antitermite treatment, M.S. flat, hold fasts of size 250 x 40 x 3mm fixed with M.S. bolt 5mm dia 50mm long duly embedded in cement concrete M-15 grade : Sal wood Grade - I. 56 Wiring of twin control light /fan / call bell point with 1.5 sq. mm nominal size FR PVC insulated unshethed flexible copper conductor 1.1 kv grade and 1.5 sq. mm nominal size FR PVC insulated unslated unsheathed flexible copper earth conductor 1.1 kv grade (IS:694) of approved make in surface / recessed ISI marked MMS (IS:9537 P - III) PVC conduit & its accessories, round tles, 18 SWG M.S. box with earth terminal, screwless cage connectors for neutral looping in switch board & false ceiling point, 6 A two way switch, 3.0 mm thick ISI marked phenolic laminated sheet, zinc plated / brass screws, cup washers, making connections, testing etc. as required. Short point (up to 3 mtr.) 57 (A) Short Point (up to 3mtr) 58 (B) Medium Point (up to 6mtr) 59 ( C ) Long Point (up to 10mtr) 60 Wiring of 3 pin 5 amp. Light plug point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kv grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kg grade (IS:694) of approved make in surface/ recessed ISI marked medium duty PVC conduit & its accessories, Hot Dipped Galvanized M.S Modular box with earth terminal, screwless cage connectors for neutral looping in switch board , 6 A modular switch, 6 A modular socket, Modular plate with grid plate, screws, making connections, testing etc. as required. On board 61 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor ISI marked (IS:694) of 1.1 kv grade and approved make in existing surface or recessed conduit/casing capping including making connections etc. as required. 62 2 x 2.5 sq. mm + 1x1.5 sqmm 63 2 x 4.0 sq. mm + 1x1.5 sqmm 64 P & F following sizes (dia) of ISI marked medium duty PVC coduit along with accessories in surface/ recessed using sadles, clamps, fastener, as required including cutting the wall and making good the same as required. Group II, 25 mm dia 65 S&F following sizesof ISI marked ( IS:14927 P - II ) PVC casing capping along with accessorieslike coupler, inner, outer, elbow, square box, tee etc. on surfacewith screws, expansionfastenersas required. 66 32 mm x 12 mm 67 50 mm x 20mm 68 Cement concrete pavement of required thickness with 1:1.5:3 (1-Cement:1.5-course sand : 3-graded stone aggregate 20 mm nominal size) including finishing complete. 69 Demolishing cement concrete manually/ by mechanical means including disposal of MATERIAL within 50 metres lead as per direction of Engineer-in-charge. 1: 3: 6 or richer mix. 70 Demolishing brick work manually/ by mechanical means including stacking of serviceable MATERIAL and disposal of unserviceable MATERIAL within 50 metres lead as per direction of Engineer-in-charge. In cement mortar. 71 Cutting of construction joint/ longitudinal joint 4 to 6 mm. wideusing mechanical concrete cutter including cost of diamond bit cutting wheel and filling of bitumen sealingcompound in groove including cost of sealing compound.100 mm depth 72 Repair to cement plaster in cement mortar 1 : 6 (1 cement : 6 fine sand) including removal of old plaster in regular shape and white or colour washing. 73 Providing and fixing Stone jali 40mm thick Red/Pink sand stone throughoutin cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment, matching the stone shade, jali patterns to be cut square to jali slab without any chamfers etc: 74 Supplying and fixing machine cut fine dressedRed/Pink sand stone dasa orcoping,with full moulding if required laid on cement mortar 1:4 including pointing with admixture of pigment matching with the stone shade. 25mm thick 75 Half Flyash Brick masonry in Superstructure , above plinth level upto floor three levelusing Flyash Bricks of designation 75 Cement mortar 1 : 6 (1 cement : 6 coarse sand) 76 Random rubble dry stone Kharanja under floor. 77 Surface dressing of the ground including removing vegetation and inequalities not exceeding 15cm deep and disposal of rubbish lead up to 50 Mtr. and lift up to 1.5 Mtr.:All kinds of soil 78 Filling in plinth with locally available river shingle under floors including watering ramming consolidating and dressing complete including cost of shingle sand. 79 Filling available excavated earth (excluding rock) in trenches, plinth side of foundation etc. in layers not exceeding 20 cm. in depth, consolidating each deposited layer by ramming and watering including lead up to 50 meter and with all lift. 80 Centering & shuttering with plywood or steel Plate including strutting, propping bracing both ways with steel propsand removal of formwork for upto floor Three level for : Walls (any thickness) including attached pilasters,buttressesplinthandstring course. 81 Supplying and fixing of chain link fencing with angle iron posts 50x50x6mm placed at every 3 Mtr. apart 30cm in ground embedded in cement concrete 1:3:6 (30x30x45cm) corner and every tenth post to be strutted with (50 x 50 x 6cm) angle iron provided and fixed and fitted with posts including earth work in excavation etc. complete with chain link size. 82 50mm x 50mm x 3.15mm 83 Providing stone slab covering over drains including filling of joints in cement sand mortar 1 : 3 with 35 mm thick cement concrete flooring 1 : 2 : 4 mix complete with good finish with :Stone slab 100 to 150 mm thick average. 84 Repair to stone masonary in cement sand mortar 1:6 with old and new stone. 85 Repair to brick masonary in cement sand mortar 1:6 withnew brick. 86 Filling expansion joint with bitumen filler in plain or Reinforced Cement Concrete 25 mm width & 25 mm deep. 87 Providing and laying water proofing treatment with thermalinsulation havingthickness of 2.5 -3.0 mm over the existing R.C.C. roof by as per direction and satisfaction of Engineer-in-Charge and consisting of:(i) Cleaning and washing of the existing roof including removing of loose material from the surface of cracks.(ii) Widening and deepening of cracks to fill the approved Crack filler as per direction of Engineer in charge.(iii) Application of one coat of approved sealing compound approved by Engineer in charge with following specification or equivalent compound @ 0.17 litres per square meter with required brush as per direction of Engineer in charge.(iv) Application of the mesh approved by Engineerin charge (made up of Glass Fiber , Woven Structure of Leno make , reinforcing with alkali resistant coating having 10x10 mesh size, weight/sqm is 90gm to 120 gm and of 0.25 mm thickness including Resin content (%) : 18% ) orequivalentand then application of coat of sealing compound approved by Engineerin charge with specifications as narrated above ,without use of water @ 0.33 litre per square meter with brush and dryingof surface for24 hoursas perdirectionof Engineerin charge. 88 Providing and Fixing Aluminium composite panel ofapproved make 3mm thick with 0.5mm thick skin & PVDF coated approved shade for wall panelling. Main framing work to be done using 50mmx25mmx1.6mm tubular section of approved make. Stainless steel screw to be used to fix the ACP panel to be fixed to the main frame with industrial adhesive tape and panel groove to be sealed with weather proof silicon sealant suitable for glass/aluminium etc. complete in all respect as approved by Engineer-in-charge. 89 Providing & fixing UV stabilised fiberglass reinforced plastic sheet roofing upto any pitch including fixing with polymer coated ‘J’ or ‘L’ hooks, bolts & nuts 8mm dia. G.I plain/bitumen washers complete but excluding the cost of purlins, rafters, trusses etc. The sheets shall be manufactured out of 2400 TEX panel rovigs incorporating minimum 0.3% Ultra-voilet stabiliser in resin system under approximately 2400 psi and hot cured. They shall be of uniform pigmentation and thickness without air pockets and shall confoim to IS 10192 and IS 12866.The sheets shall be opaque or translucent, clear or pigmented, textured or smooth as specified. 90 5.0mm thick (Wt. 8.4 Kg./Mtr. Sq.) 91 Random Rubble stone masonry with hard stone in superstructure aboveplinth level and upto Three Levelabove 30cm. thick walls in : Cement Mortar 1:6 ( 1-Cement : 6-Sand). 92 Providing and fixing Marble stone flooring table rubbed, 15-18 mm thick over 20mm (Av.) thick base of CM 1:4 (1 cement : 4 coarse sand) jointing with white cement mortar 1:2 (1 white cement : 2 marble dust) with pigment to match the shade of the marble slab including grinding, rubbing and polishing complete. WHITE MARBLE : Makrana Adanga. 801 Cm2 to 1500 Cm2 Tiles 93 P & F G.I. pipes (Internal Work) with G.I. Fittings excluding union (IS:1239 Mark) & MS clamps including cutting and making good the walls and floors: Exposed on wall 94 15 mm dia nominal bore B Class 95 25 mm dia nominal bore A Class 96 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor ISI marked (IS:694) of 1.1 kV grade and approved make in existingsurface or recessed conduit/casing capping including making connections etc. as required. 97 4 x 10.0 sq.mm 98 4 x 16.0 sq.mm 99 SITC of 11 KV, 400/630 A, 20kA / 3 sec, Out door,Extensible type Ring main unit (RMU) in suitable RCC foundation with 2 no. Load break switch & 1 no. VCB / SF6 circuit breaker with over load, Earth fault, short circuit relay, copper bus bar, earthing switch, mechanical ON / OFF /Earth indication, Voltage presence indicator, Ring core protection CT 2.5 VA, 10P10 as per transformer rating, Shunt trip coil, Anti reflex operating handle, right angle boots etc. as required. 100 Providing and Fixing corrugated colour G.I sheet having thickness 0.50mm roofing fixed with G.I.J or L Hooks bolts and nuts 8mm dia meetr with bitumen and G.I Limpet washers or with G.I Limpet washers filled with white lead and including over lapping of sheet complete ( upto a pitch of 60 degree) & excluding the cost of purlins rafters and trusses etc complete in all respect. 101 Providing & Fixing of HDPE pipe ISI mark (IS:4984/95) for water supply (suitable for submersible & jet pump) with required fittings 102 40 mm OD6 kg / cm2 103 50 mm OD6 kg / cm2 104 63 mm OD6 kg / cm2 105 P/Laying P.V.C./ XLPE insulated & P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor of IS:1554 P-I / IS :7098 P - I of Group 1 of approved makein ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick underlayer ofsand,IInd class bricks covering, refilling earth,compaction of earth, making necessary connection, testing etc. as required of size. 106 10.0 Sq.mm 107 4 core 108 16.0 Sq.mm 109 4 core 110 70.0 Sq,mm 111 3.5 core 112 120.0 Sq.mm 113 3.5 core 114 SITC of radial / mixed flow submersible motor pump sets ISI marked (IS:8034-1989) of approved make with required accessories including making connection suitable for T.W./ D.C.B./ Open well. The job includes lowering ofriser pipe, G.I./H.D.P.E. pipe with rope, cables, installation of complete fitting and accessories, jointing of electrical cables up to switch board. All labour for testing of submersible pumps set and supply of water to water mains, complete in all respect.150 mm diameter Submersible pump shall havefollowing HP Rating, phase, Head, minimum Discharge respectively. 115 5.0 HP, 3-Ø, (32-52)Mtr, (400-167)LPM 116 7.5 HP, 3-Ø, (45-73)Mtr, (400-280)LPM 117 10.0 HP, 3-Ø, (64-104)Mtr, (400-167)LPM 118 Construction of Tube-well upto 100 Meter depth and above in all type of rocks by DTH system and over burden, to accommodate casing pipe of following sizes in all types of soils and over burden including lowering of casing pipes, but excluding cost of casingpipes as per IS : 2800 (Part I & II) 1979 specifications. The work would be completed after obtaining sand free water. The tube well should have a throughout bore as per nominal dia of casing pipe: 119 200 mm –do- 120 Supply of ERW M.S. black casing pipe ISI marked (IS:4270/1992) of grade Fe410 of following sizes at site of work. 121 Nominal bore of pipe (mm) 200 122 Testing verticality of tube-well by plumbing system and yield test and draw down test by pumping system as per IS: 2800 (Part II) 1979. 123 S & F tube well cover ofM.S.sheet (6mm thick) with nuts and bolts complete for casing size: 124 200mm dia 125 S & F M.S. clamp, set of 50 ×6mm flat iron with nuts and bolts etc. for holding the riser pipe assembly of submersible pump set. 126 Installation of submersible motor pump set in Tube-well/open well complete ( LABOUR charges only) including transportation of tripod, chain pulley block & any other MATERIAL required for lowering purpose. 127 P/Laying ISI marked P.V.C. insulated submersible cable confirming to IS:694 with flexible copper conductor including making connection etc. as required. 128 6.0 Sq.mm 3 core flat / Round 129 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor ISI marked (IS:694) of 1.1 kV grade and approved make in existingsurface or recessed conduit/casing capping including making connections etc. as required. Group-1 130 1 x 1.5 sq.mm 131 1 x 2.5 sq.mm 132 1 x 4.0 sq.mm 133 S&F following sizes (dia.) of ISI marked medium duty PVC conduit along with accessories in surface / recessed using saddles, clamps, fastener as required includingcutting the wall, covering conduit and making good the same as required. Group-1 134 25 mm 135 P&F 240/415 V AC MCB with positive isolation of breaking capacity not less than 10 KA (B/ C/ D tripping characteristic) ISI marked IS 8828(1996)]/ conforming to IEC 60898 in existing board/sheets including making connections, testing etc. as required.Single pole MCB , 6 A to 32 A rating Group-1 136 P&F Recessed/ Surface mounting heavy duty horizontal type sheet steel Distribution board phophatised/ powder painted complete with suitable rating insulated copper bus bar, shorting link , neutral link, earth link and din bar,masking sheet, conforming to IS13032 & IS8623 including making internal DBterminations with copper lugs , testing etc. as required. Double door (Three phase) 12 Way Group-1 137 P&F 240/415 V isolator conforming to IS:13947-III/ IEC 60947-3 on existing board / sheet including making connections, testing etc. as required. Four pole Isolator 63 A rating Group-1 138 Providing and Fixing corrugated colour G.I sheet having thickness 0.50mm roofing fixed with G.I.J or L Hooks bolts and nuts 8mm dia meetr with bitumen and G.I Limpet washers or with G.I Limpet washers filled with white lead and including over lapping of sheet complete ( upto a pitch of 60 degree) & excluding the cost of purlins rafters and trusses etc complete in all respect.

Key Value

Document Fees
INR 7500 /-
EMD
INR 800000.0 /-
Tender Value
INR 4 Crore /-

BOQ Items

Name of Work:Various Civil Work and Repairing work in Div.-II-A Area. (ARC)
Sl. No. Item Description
1Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed with in a lead of 50 meter.All kinds of soils
2Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30cm in depth. 1.5m in width as well as 10 sqm on plan) including disposal ofexcavated earth, lead upto 50m andlift upto 1.5 m , disposed earth to be levelled and neatly dressed: All kinds of soil
3Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. M10 grade Nominal Mix 1: 3: 6 (1 cement : 3 coarse sand : 6 graded stoneaggregate 20mm nominal size).
4Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level.M20 grade Nominal Mix 1: 1.5: 3 (1 cement : 1.5 coarse sand : 3 graded stoneaggregate 20mm nominal size).
5Random Rubble stone masonry for with hard stone in foundation and plinth in Cement Sand mortar above 30 CM thick wall in:Cement Mortar 1:6 ( 1-Cement : 6-Sand).
6Providing and laying damp-proof course with cement concrete grade M-150 (1 : 2 : 4) mortar prepared with 1% solution of water-proof compound complete as per specification . 50mm thick.
7Plaster on new surface on walls in cement sand mortar 1:6 including racking of joint etc. complete fine finish : 20mm thick.
8Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry, making of lines or groove etc complete but excluding the cost of nosing of steps etc. complete. 50mmthickwith20mmthicknominalsizeaggregate.
9Centering and Shuttering with plywood or steel plate including strutting, propping bracing both ways and removal of formwork for foundation , footings,strap beam, raft , bases of columns etc.
10Providing and laying in position specified grade ofcement concrete forall RCC structural elements upto plinth level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement. M20 grade Nominal Mix
11Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor Three level.
12M-40,80mm thick to be used in medium-traffic (Medium trafficis defind as a daily traffic of 150-450 commercial vehicles exceeding 30 KN laden weight , or an equivalent of 0.5 to 2.0 MSA for a design life of 20years) like city streets, small and medium market roads, low volume roads ,ytility cuts on arterial roads, etc. Category "B"denated only two side like I,Z,T shape etc. as per IRC SP 63:2004
13Add extra over rates of 1A to E, if colored paver blocks are used
14Supply & Stacking good soil of earth at site complete including loading unloading & Transportation etc. Good soil of earth
15Spreading of manure and good earth in required thickness (cost of manure and good earth to be paid separately).
16S & FCC 1:2:4 (M15) Precast kerb on dand upto 60 cm length over 20 mm thick base of cement mortar 1:6 including jointing, earthwork, painting and jointing with cement mortar 1:4 of size.15 × 40 cm
17Polished Blue Kota stone flooring skirting, laid over 20 mm thick base of C.M. 1 : 4 and jointed with grey cement slurry to match the shade of the slab including rubbing and polishing complete :For area of each slab from 2001 to 5000 Sq.Cm : 25 mm thick slab.
18Rough chisel dressed stone flooring over 20 mm (Av.) thick base in CM 1 : 6 including pointing with cement mortar 1 : 2 (1 cement : 2 stone dust) with and admixture of pigment to match the shade of stone with joint thickness upto 15 mm : 35 mm thick red sand stone.
19Providing and fixing steel gate, grating , and grills made of angles, tees, square bars, flats,or black pipe with holdfast and fittings complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide
20Add extra if square, rectangular hollow tubular sections are used.
21Painting with synthetic enamel paint of approved brand and manufacture togive an even shade : Two or more coats on new work
22Painting with synthetic enamel paint of approved brand and manufacture togive an even shade : One or more coats on old work.
23Finishing wall with water proofing cement paint of approved brand and manufacture and or required shadetogive an even shade including all scaffolding: On new surface.
24Finishing wall with water proofing cement paint of approved brand and manufacture and or required shadetogive an even shade including all scaffolding: On old surface.
25Providing stone slab covering over drains including filling of joints in cement sand mortar 1 : 3 with 35 mm thick cement concrete flooring 1 : 2 : 4 mix complete with good finish with : Stone slab 40 to 50 mm thick average.
26Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. M20 grade Nominal Mix 1: 1.5: 3 (1 cement : 1.5 coarse sand : 3 graded stoneaggregate 20mm nominal size).
27Flyash Brick masonry with Flyash Bricks of class designation 75infoundation and plinth. Cement mortar 1 : 6 (1 cement : 6 coarse sand)
28Flyash Flyash Brick work with flyash Flyash Bricks of class designation 75 in superstructure above plinth level upto floor Three Level in all shapes and sizes in :Cement mortar 1 : 6 (1 cement : 6 coarse sand)
29Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard jointed with neat cement slurry mixed with pigment to match the shade of tiles includingrubbing and cleaning etc. complete on 20 mm thick bed of cement mortar 1:4 (1 cement : 4 coarse sand) Light shade using shade cement.
30P&F rigid PVC Pipe (IS:4985 mark) class II/ (4 Kg. /Cm2.) approved quality /makeincluding joining the pipe with solvent cement rubber ring and lubricant. 110 mm dia
31Providing and laying Reinforced cement concrete pipes NP-3 for culverts including jointing ends and fixing collar with cement mortar 1:2. (MoRTH specification : clause 1000/2900).
32300 mm dia
33600 mm dia
34Providing and fixing 15 to 20 mm thick Granite stone slab mirror polished and machine edge cut in walls, pillars, steps, Shelves, Sills Counters, Floors etc. laid on 12 mm (Av.) thick base of cement mortar 1 : 3 (1 cement : 3 coarse sand) jointing with white cement mortar 1 : 2 (1 white cement : 2 marble dust) with pigment to match the shade of the granite slab complete including rubbing and polishing of :Jhansi (Red/Chocolate colour) Above 3601 cm2 slabs
35Transportation of excavated of earth from site including loading unloading etc. complete with all lead and lift. Lead upto 5 Km.
36Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade : Two or more coats on new work including preparation of base with primer, putty, lippy complete in all respect.
37Painting exterior surface ofWallwith 100% acrylic exterior paint of approved brand and manufacture to give an even shade with two or more coats including prepartion of base with sand papering, primer, putty,etc complete in all respect. New Work
38Providing and applying white cement based puttyover plastered surface to prepare the surface even and smooth complete
39Providing, laying and spreading of granular sub-base by providing coarse graded Material, spreading in uniform layers with motor grader on prepared surface mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per MoRTH Specification : clause No. 401. Grading-III
40P & F Stone cladding / Flooring works dressed bansi paharpur stone 25mm thick in traditional style used in cladding/Flooring with pattern over 25 to 50 mm thick base in CM 1:6 including pointing with cement mortar 1:2 (cement : 2 stone dust) matche the shade of stone with joint thickness upto 1.5mm as per direction of engineer-in-charge.
41Single piece of stone element with carving work in Bansi Paharpur stone includes stone pillar, stone base, todies and thabi etc carving work as per direction of engineer in charge
42Providing and fixing 1st quality standard white, grey, ivory, fume red brown, light green, light blue and other light shades glazed tiles confirming to IS : 13753 & IS :15622 of size 300mm x 450mm in walls, floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (excluding the cost of cement plaster on walls and pillar).
43Providing and fixing 1st quality MAT finished ceremic tile size 300x300mm confirmingto IS : 13755 and IS : 15622 colour such as white, grey, ivory, fume red brown, light green, light blue and other light shades in floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (including the cost of cement mortar bed 1:4).
44P/Laying P.V.C./ XLPE insulated & P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor of IS:1554 P-I / IS :7098 P - I of Group 1 of approved makein ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick underlayer ofsand,IInd class bricks covering, refilling earth,compaction of earth, making necessary connection, testing etc. as required of size. 4.0 Sq.mm 4 core
45P/Laying P.V.C./ XLPE insulated & P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor of IS:1554 P-I / IS :7098 P - I of Group 1 of approved makein ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick underlayer ofsand,IInd class bricks covering, refilling earth,compaction of earth, making necessary connection, testing etc. as required of size. 6.0 Sq.mm 4 core
46P&F strip type fluorescent tube fitting fabricated from (CRCA) sheet and finished with powder coating/stove enamelled paint/ (extruded non corrosive UV resist EP channel) complete with accessories like (OCCB, starter, starter seat) / EB, rotor holder, terminal block duly prewired with copper conductor including making connection, testing etc. as required. (without tube) 1×36 watts with OCCB, Group-I
47P&F fluorescent tube rod in existing fixtures as required. Fluorescent powder coated 36/40 watts, Group-II
48P & F double ball bearing capacitor start, aluminium body & blade ceilingfanwith down rod up to 30 cm with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required.1200 mm sweep.Group-I
49Providing and fixingaluminum workfor doors ,windows, ventilators and partition with extruded built up standard tubular / appropriate Z sections and other sections of approved make conforming to IS :733 and IS :1285,fixed with rawl plugs and screws or with fixing clips ,or with expansion hold fasteners including necessary filling up of gap. at junctions , at top ,bottom and sides with required PVC/neoprene felt etc. Aluminium section shall be smooth ,rust free, straight ,mitered and jointed mechanically wherever required including cleat angle Aluminium snap beading for glazing /paneling , C.P. brass/ stainless steel screws Al. Tower bolt & Al. handle & Al. Aldrop etc.,all complete as per architectural drawings and thedirections of Engineer- in – charge .(Glazing and paneling to be paid for separately). Anodised aluminum (anodised transparent 81 dyed to required shade according to IS : 1868. (Minimum anodic coating of grade AC 15, Anodizing to be got done from approved Anodizer) For fixed portion
50For shutters builtup standard tubular sections of openable doors ,windows & ventilators including providing & fixing hinges / rollers etc. and making provision for fixing of fittings wherever required (lockes shall be paid for separately). Anodised aluminum (anodised transparent 81 dyed to required shade according to IS : 1868. (Minimum anodic coating of grade AC 15, Anodizing to be got done from approved Anodizer)
51Providing and fixing 12 mm thick prelaminated three layer medium density (exterior grade ) particle board Grade I, Type II conforming to IS : 12823 bonded formaldehyde synthetic resin ,of approved brand and manufacture in paneling fixed in aluminium doors ,windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and direction of engineer-in-charge. Prelaminated particle board with decorative lamination on both sides.
52Providing and fixing glazing in aluminium door, window ,ventilator shutters and partitions etc. with PVS / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge.(Cost of aluminium snap beading shall be paid in basicitem.) With glass panes of 4.0 mm thickness ( weight not less than 10.0 kg/sqm) as per IS : 2835.
53Providing and fixing expanded grill made of aluminum as per design and drawing having members section of size 7.5mm x 6.0mm and opening of size 102mm x 99mm to aluminum window/vent with required screws, Y and H aluminium sec (as per drawing) at the ends and middle joints respectively complete in all respect as per direction of engineer in charge. Anodised aluminum (anodised transparent 81 dyed to required shade according to IS : 1868. (Minimum anodic coating of grade AC 15, Anodizing to be got done from approved Anodizer)
54Providing and fixing external grade board solid core single leaf flush door shutters ISI 2202-67 marked using Phenol formal dehyderesinin glue both sides with approved steel fittings complete as per annexure "A":30 mm thick commercial Veneer Both side
55Providing& fixing door, window, chowkhats and other frames, including antitermite treatment, M.S. flat, hold fasts of size 250 x 40 x 3mm fixed with M.S. bolt 5mm dia 50mm long duly embedded in cement concrete M-15 grade : Sal wood Grade - I.
56Wiring of twin control light /fan / call bell point with 1.5 sq. mm nominal size FR PVC insulated unshethed flexible copper conductor 1.1 kv grade and 1.5 sq. mm nominal size FR PVC insulated unslated unsheathed flexible copper earth conductor 1.1 kv grade (IS:694) of approved make in surface / recessed ISI marked MMS (IS:9537 P - III) PVC conduit & it"s accessories, round tles, 18 SWG M.S. box with earth terminal, screwless cage connectors for neutral looping in switch board & false ceiling point, 6 A two way switch, 3.0 mm thick ISI marked phenolic laminated sheet, zinc plated / brass screws, cup washers, making connections, testing etc. as required. Short point (up to 3 mtr.)
57(A) Short Point (up to 3mtr)
58(B) Medium Point (up to 6mtr)
59( C ) Long Point (up to 10mtr)
60Wiring of 3 pin 5 amp. Light plug point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kv grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kg grade (IS:694) of approved make in surface/ recessed ISI marked medium duty PVC conduit & it"s accessories, Hot Dipped Galvanized M.S Modular box with earth terminal, screwless cage connectors for neutral looping in switch board , 6 A modular switch, 6 A modular socket, Modular plate with grid plate, screws, making connections, testing etc. as required. On board
61Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor ISI marked (IS:694) of 1.1 kv grade and approved make in existing surface or recessed conduit/casing capping including making connections etc. as required.
622 x 2.5 sq. mm + 1x1.5 sqmm
632 x 4.0 sq. mm + 1x1.5 sqmm
64P & F following sizes (dia) of ISI marked medium duty PVC coduit along with accessories in surface/ recessed using sadles, clamps, fastener, as required including cutting the wall and making good the same as required. Group II, 25 mm dia
65S&F following sizesof ISI marked ( IS:14927 P - II ) PVC casing capping along with accessorieslike coupler, inner, outer, elbow, square box, tee etc. on surfacewith screws, expansionfastenersas required.
6632 mm x 12 mm
6750 mm x 20mm
68Cement concrete pavement of required thickness with 1:1.5:3 (1-Cement:1.5-course sand : 3-graded stone aggregate 20 mm nominal size) including finishing complete.
69Demolishing cement concrete manually/ by mechanical means including disposal of MATERIAL within 50 metres lead as per direction of Engineer-in-charge. 1: 3: 6 or richer mix.
70Demolishing brick work manually/ by mechanical means including stacking of serviceable MATERIAL and disposal of unserviceable MATERIAL within 50 metres lead as per direction of Engineer-in-charge. In cement mortar.
71Cutting of construction joint/ longitudinal joint 4 to 6 mm. wideusing mechanical concrete cutter including cost of diamond bit cutting wheel and filling of bitumen sealingcompound in groove including cost of sealing compound.100 mm depth
72Repair to cement plaster in cement mortar 1 : 6 (1 cement : 6 fine sand) including removal of old plaster in regular shape and white or colour washing.
73Providing and fixing Stone jali 40mm thick Red/Pink sand stone throughoutin cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment, matching the stone shade, jali patterns to be cut square to jali slab without any chamfers etc:
74Supplying and fixing machine cut fine dressedRed/Pink sand stone dasa orcoping,with full moulding if required laid on cement mortar 1:4 including pointing with admixture of pigment matching with the stone shade. 25mm thick
75Half Flyash Brick masonry in Superstructure , above plinth level upto floor three levelusing Flyash Bricks of designation 75 Cement mortar 1 : 6 (1 cement : 6 coarse sand)
76Random rubble dry stone Kharanja under floor.
77Surface dressing of the ground including removing vegetation and inequalities not exceeding 15cm deep and disposal of rubbish lead up to 50 Mtr. and lift up to 1.5 Mtr.: All kinds of soil
78Filling in plinth with locally available river shingle under floors including watering ramming consolidating and dressing complete including cost of shingle sand.
79Filling available excavated earth (excluding rock) in trenches, plinth side of foundation etc. in layers not exceeding 20 cm. in depth, consolidating each deposited layer by ramming and watering including lead up to 50 meter and with all lift.
80Centering & shuttering with plywood or steel Plate including strutting, propping bracing both ways with steel propsand removal of formwork for upto floor Three level for : Walls (any thickness) including attached pilasters,buttressesplinthandstring course.
81Supplying and fixing of chain link fencing with angle iron posts 50x50x6mm placed at every 3 Mtr. apart 30cm in ground embedded in cement concrete 1:3:6 (30x30x45cm) corner and every tenth post to be strutted with (50 x 50 x 6cm) angle iron provided and fixed and fitted with posts including earth work in excavation etc. complete with chain link size.
8250mm x 50mm x 3.15mm
83Providing stone slab covering over drains including filling of joints in cement sand mortar 1 : 3 with 35 mm thick cement concrete flooring 1 : 2 : 4 mix complete with good finish with :Stone slab 100 to 150 mm thick average.
84Repair to stone masonary in cement sand mortar 1:6 with old and new stone.
85Repair to brick masonary in cement sand mortar 1:6 withnew brick.
86Filling expansion joint with bitumen filler in plain or Reinforced Cement Concrete 25 mm width & 25 mm deep.
87Providing and laying water proofing treatment with thermalinsulation havingthickness of 2.5 -3.0 mm over the existing R.C.C. roof by as per direction and satisfaction of Engineer-in-Charge and consisting of: (i) Cleaning and washing of the existing roof including removing of loose material from the surface of cracks. (ii) Widening and deepening of cracks to fill the approved Crack filler as per direction of Engineer in charge. (iii) Application of one coat of approved sealing compound approved by Engineer in charge with following specification or equivalent compound @ 0.17 litres per square meter with required brush as per direction of Engineer in charge. (iv) Application of the mesh approved by Engineerin charge (made up of Glass Fiber , Woven Structure of Leno make , reinforcing with alkali resistant coating having 10x10 mesh size, weight/sqm is 90gm to 120 gm and of 0.25 mm thickness including Resin content (%) : 18% ) orequivalentand then application of coat of sealing compound approved by Engineerin charge with specifications as narrated above ,without use of water @ 0.33 litre per square meter with brush and dryingof surface for24 hoursas perdirectionof Engineerin charge.
88Providing and Fixing Aluminium composite panel ofapproved make 3mm thick with 0.5mm thick skin & PVDF coated approved shade for wall panelling. Main framing work to be done using 50mmx25mmx1.6mm tubular section of approved make. Stainless steel screw to be used to fix the ACP panel to be fixed to the main frame with industrial adhesive tape and panel groove to be sealed with weather proof silicon sealant suitable for glass/aluminium etc. complete in all respect as approved by Engineer-in-charge.
89Providing & fixing UV stabilised fiberglass reinforced plastic sheet roofing upto any pitch including fixing with polymer coated ‘J’ or ‘L’ hooks, bolts & nuts 8mm dia. G.I plain/bitumen washers complete but excluding the cost of purlins, rafters, trusses etc. The sheets shall be manufactured out of 2400 TEX panel rovigs incorporating minimum 0.3% Ultra-voilet stabiliser in resin system under approximately 2400 psi and hot cured. They shall be of uniform pigmentation and thickness without air pockets and shall confoim to IS 10192 and IS 12866.The sheets shall be opaque or translucent, clear or pigmented, textured or smooth as specified.
905.0mm thick (Wt. 8.4 Kg./Mtr. Sq.)
91Random Rubble stone masonry with hard stone in superstructure aboveplinth level and upto Three Levelabove 30cm. thick walls in : Cement Mortar 1:6 ( 1-Cement : 6-Sand).
92Providing and fixing Marble stone flooring table rubbed, 15-18 mm thick over 20mm (Av.) thick base of CM 1:4 (1 cement : 4 coarse sand) jointing with white cement mortar 1:2 (1 white cement : 2 marble dust) with pigment to match the shade of the marble slab including grinding, rubbing and polishing complete. WHITE MARBLE : Makrana "Adanga". 801 Cm2 to 1500 Cm2 Tiles
93P & F G.I. pipes (Internal Work) with G.I. Fittings excluding union (IS:1239 Mark) & MS clamps including cutting and making good the walls and floors: Exposed on wall
9415 mm dia nominal bore "B" Class
9525 mm dia nominal bore "A" Class
96Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor ISI marked (IS:694) of 1.1 kV grade and approved make in existingsurface or recessed conduit/casing capping including making connections etc. as required.
974 x 10.0 sq.mm
984 x 16.0 sq.mm
99SITC of 11 KV, 400/630 A, 20kA / 3 sec, Out door,Extensible type Ring main unit (RMU) in suitable RCC foundation with 2 no. Load break switch & 1 no. VCB / SF6 circuit breaker with over load, Earth fault, short circuit relay, copper bus bar, earthing switch, mechanical ON / OFF /Earth indication, Voltage presence indicator, Ring core protection CT 2.5 VA, 10P10 as per transformer rating, Shunt trip coil, Anti reflex operating handle, right angle boots etc. as required.
100Providing and Fixing corrugated colour G.I sheet having thickness 0.50mm roofing fixed with G.I.J or L Hooks bolts and nuts 8mm dia meetr with bitumen and G.I Limpet washers or with G.I Limpet washers filled with white lead and including over lapping of sheet complete ( upto a pitch of 60 degree) & excluding the cost of purlins rafters and trusses etc complete in all respect.
101Providing & Fixing of HDPE pipe ISI mark (IS:4984/95) for water supply (suitable for submersible & jet pump) with required fittings
10240 mm OD6 kg / cm2
10350 mm OD6 kg / cm2
10463 mm OD6 kg / cm2
105P/Laying P.V.C./ XLPE insulated & P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor of IS:1554 P-I / IS :7098 P - I of Group 1 of approved makein ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick underlayer ofsand,IInd class bricks covering, refilling earth,compaction of earth, making necessary connection, testing etc. as required of size.
10610.0 Sq.mm
1074 core
10816.0 Sq.mm
1094 core
11070.0 Sq,mm
1113.5 core
112120.0 Sq.mm
1133.5 core
114SITC of radial / mixed flow submersible motor pump sets ISI marked (IS:8034-1989) of approved make with required accessories including making connection suitable for T.W./ D.C.B./ Open well. The job includes lowering ofriser pipe, G.I./H.D.P.E. pipe with rope, cables, installation of complete fitting and accessories, jointing of electrical cables up to switch board. All labour for testing of submersible pumps set and supply of water to water mains, complete in all respect. 150 mm diameter Submersible pump shall havefollowing HP Rating, phase, Head, minimum Discharge respectively.
1155.0 HP, 3-Ø, (32-52)Mtr, (400-167)LPM
1167.5 HP, 3-Ø, (45-73)Mtr, (400-280)LPM
11710.0 HP, 3-Ø, (64-104)Mtr, (400-167)LPM
118Construction of Tube-well upto 100 Meter depth and above in all type of rocks by DTH system and over burden, to accommodate casing pipe of following sizes in all types of soils and over burden including lowering of casing pipes, but excluding cost of casingpipes as per IS : 2800 (Part I & II) 1979 specifications. The work would be completed after obtaining sand free water. The tube well should have a throughout bore as per nominal dia of casing pipe:
119200 mm –do-
120Supply of ERW M.S. black casing pipe ISI marked (IS:4270/1992) of grade Fe410 of following sizes at site of work.
121Nominal bore of pipe (mm) 200
122Testing verticality of tube-well by plumbing system and yield test and draw down test by pumping system as per IS: 2800 (Part II) 1979.
123S & F tube well cover ofM.S.sheet (6mm thick) with nuts and bolts complete for casing size:
124200mm dia
125S & F M.S. clamp, set of 50 ×6mm flat iron with nuts and bolts etc. for holding the riser pipe assembly of submersible pump set.
126Installation of submersible motor pump set in Tube-well/open well complete ( LABOUR charges only) including transportation of tripod, chain pulley block & any other MATERIAL required for lowering purpose.
127P/Laying ISI marked P.V.C. insulated submersible cable confirming to IS:694 with flexible copper conductor including making connection etc. as required.
1286.0 Sq.mm 3 core flat / Round
129Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor ISI marked (IS:694) of 1.1 kV grade and approved make in existingsurface or recessed conduit/casing capping including making connections etc. as required. Group-1
1301 x 1.5 sq.mm
1311 x 2.5 sq.mm
1321 x 4.0 sq.mm
133S&F following sizes (dia.) of ISI marked medium duty PVC conduit along with accessories in surface / recessed using saddles, clamps, fastener as required includingcutting the wall, covering conduit and making good the same as required. Group-1
13425 mm
135P&F 240/415 V AC MCB with positive isolation of breaking capacity not less than 10 KA (B/ C/ D tripping characteristic) ISI marked IS 8828(1996)]/ conforming to IEC 60898 in existing board/sheets including making connections, testing etc. as required.Single pole MCB , 6 A to 32 A rating Group-1
136P&F Recessed/ Surface mounting heavy duty horizontal type sheet steel Distribution board phophatised/ powder painted complete with suitable rating insulated copper bus bar, shorting link , neutral link, earth link and din bar,masking sheet, conforming to IS13032 & IS8623 including making internal DBterminations with copper lugs , testing etc. as required. Double door (Three phase) 12 Way Group-1
137P&F 240/415 V isolator conforming to IS:13947-III/ IEC 60947-3 on existing board / sheet including making connections, testing etc. as required. Four pole Isolator 63 A rating Group-1
138Providing and Fixing corrugated colour G.I sheet having thickness 0.50mm roofing fixed with G.I.J or L Hooks bolts and nuts 8mm dia meetr with bitumen and G.I Limpet washers or with G.I Limpet washers filled with white lead and including over lapping of sheet complete ( upto a pitch of 60 degree) & excluding the cost of purlins rafters and trusses etc complete in all respect.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail