Housing Urban and Rular Development Government Departments Closing in 0 days TDR #32808663

Up-Gradation Of Industrial Estate, Jagatpur, Cuttack, Odisha Under Micro And Small Enterprises Cluster Development Programme (Mse-Cdp) Scheme.

Issued by Government Departments · jagatpur, Odisha
Tender Value
3.87 Crore
Estimated cost
Bid Submission
11 Jul 2022
0 days left
EMD
Ref. Documents
Bank guarantee accepted
Document Fee
11800
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
jagatpur → Odisha
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Up-Gradation Of Industrial Estate, Jagatpur, Cuttack, Odisha Under Micro And Small Enterprises Cluster Development Programme (Mse-Cdp) Scheme.

BOQ

Name of Work : Up-gradation of Industrial Estate, Jagatpur, Cuttack, Odisha under Micro & Small Enterprises Cluster Development Programme (MSE-CDP) Scheme.
Sl. No. Item Description
1Land Filling/ Levelling including Boundary Wall & Fencing
2Construction, Providing, Supplyingand fixing precast RCC/ SFRC fencing compound wall poles having finished dimension of 200mmx200mmx3000mm (long) made of M-30 grade concrete with 10 nos of 4mm dia HTPC (High Tension Pre Coated) wire, fixed in cast-in-situ PCC M-20 concrete in foundation footing of size 600 mm dia 300mm depth from top and P.C.C. of proportion in C.C.(1:4:8) ofsize 600 mm dia 300mm depth at bottom inside the RCC collar pipe of 600mm internal dia placed over a base ofplain cement conrete of proportion with C.C. (1:4:8) of size 680 mm dia 100mm depth includingexcavating foundation pit for each polein Hard soil of size 680 mm dia 700mm depth including wtering & curing for required days, alongwith supplying, fitting & fixing of precast RCC/ SFRC slab having dimension of 2100mm (long) x 300mm (wide) x 50mm (thick) 7nos. per span, made with M-30 grade concrete having 4mm dia GI HTPC wire 4 nos. covering the top of the compound wall poles with a precast RCC/ SFRC cover of size (300X300X150) mmin order to prevent the slab pannels from removing. All complete as a set to be measured in term of running meter including such precast RCC/ SFRC top cover, slab, pole, including painting two coats of approved cement paint over a coat of cement wash including curing cost and conveyance of all materials, royalties, taxes all labour, labour cess, T & P required for the work etc. complete including dewatering if required as per the direction of theEngineer-in-charge excluding cost of GST.
3Earthwork in excavation of foundation trenches and column foundation and pits in hard soil including dressing the sides and levelling the bed withen 50mtr. initial lead & 1.5mtr initial lift including cost of all lavour, sundries, T&P etc. all complete as per direction of E.I.C.
4Filling in foundation trenches and plinth with excavatedearth well watered and rammed in layers not exceeding 23 c.m in depth including all lead and lift, cost of all labour, sundries, T&P required for the work etc. complete in all respect as directed by the Engineer- in- charge.
5Supplying and filling foundation and plinth with fine river sand including watering and ramming etc complete.
6Providing and layingPlain Cement Concreteof proportion (1:3:6)infoundation and floors (i.e. below the base course of the flooring) using cement ,40 mm size crusher broken H.G Stone Metaland screened & washed sharpriver sand for mortar of approved quality & from approved quarry including hoisting, lowering and laying concrete to the required level, ramming, watering & curing etc complete to required levels, laid in layers not exceeeding 15cm thick in each layer including hire and running charges of water pumprequired for the worketc complete in all respect as directed by the Engineer-in-charge.
7Providing, mixing, lifting, hosting and laying C.C for RCC work in M-20 grade of concrete (1:1.5:3) using 40mm and down graded crusher broken chips in plinth band etc. complete
8Providing & Constructing Fly Ash Brick masonary in cm(1:4) in F & P etc. complete
9Providing, 12mm thick cement plaster in cm(1:6) etc. complete
10Providing Fe-500 tor bar reinforcement for R.C.C. work including cutting, bending and binding and tying the grills and placing in position including cost of binding wire 18 to 20 gauge.
11Providing of H.P Nut-bolts of size of (2x8) 16 nos of 30mm dia & 900mm long
12Providing Mild Steel Channel, Beam, Plate, Angle etc complete as per speciefication mentioned in approved Drawing
13Labour charges for making steel Barrier sinage gate consisting of three nos. of M.S columns 9\"-6\" hight with a guider of 33\"-0\" length as per the approval drawing, welding at site to steel Members, T&P, scaffolding etc. complete. At site as per the direction of Engineer-in-charge.
14Transportation of steel Barrior sinage gate of 33\"-0\" x 9\"-0\" size with loading and unloading at site by mechanical means for all steel members.
15Erection of M.S Barrier synage gate of size 33\" x 9\" 6\" consisting three nos of column fitted on the RCC structure with a gadder beam and stay by mechanical means, T&P, scaffolding etc. complete.
16Providing supplying & fixing of Tetro-reflective signage sheet including lettering & borders etc. Complete.
17Base Sheet & Borders
18Lettering
19Providing supplying fitting & fixing of 1m. Thick colour coated G.P sheet for pesting of R.R sheet etc. Complete.
20Laying roads
21Earth work in hard soil or gravelly soil in embankments, roads, etc. maximum laboratory dry density not less than 1.44Gm/1.52Gm/1.65Gm per cubic centimeter in road embankments respectively upto 3m/more than 3m high and top 0.5m below sub-grade level within 50m initial lead and 1.5m initial lift from approved borrow pits away from the toe of the final section of the road embankment bottom of the pit not being cut be an imaginary lines having a slope 1:4 projected from the edge of the final section of the bank including rough dressing and breaking colds maximum 5cm to 7cm and laying in layers each layer not exceeding 23cm in depth upto required level including removal of roots, shrubs, bushes and all foreign debris from the earth and benching the old embankment, sectioning and cambering the earth work, cost and conveyance of all materials T&P articles required for the work complete in all respect as per specification of N.H. work and direction of the Engineer-in-charge and to be measured on section measurement after compaction under OMC condition (100 cum) including cost of controlled compactin with PRR watering upto O.M.C. & confirming to approved specification including hire& running charges of PRR.
22Providing granular sub-base Grading - I as per table 400 - 1
23Providing granular sub-base Grading - II as per table 400 - 1
24Scarifying and removal of B.T.surface & stacking the useful materials away from work site with all leads and lifts including all labour,T & P ,sundries etc.complete as per the direction of Engineer in charge.
25Providing stone screened dust Blanket on the road surface as a leveling coarse using approved quality stone screened dust from approved quarry, laying in layers not exceeding 150mm thick including watering and compacting by 8-10T PRR including cost and conveyance of stone screened dust, all taxes, royalties, all labour, T&P, sundries, hire & running charges of PRR etc all complete, as per the direction of Engineer-in-charge.
26Construction of DLC sub-base over a prepared sub-grade with coarse and fine aggregates confirming to IS:383, the size of coarse aggregates not exceeding 25mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 Kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, laid with a pever with electronic sensor, compacting with 8-10 tonne vibratory roller, finishing and curing.
27Construction of un-reinforce, dowel jointed at expansion & construction joint only using steel @ 10.10 Kg./ Cum. approximately or as per approved design & drawing, PCC pavement as per design of M-30, over a prepared sub-base with 43gradedcement, coarse & fine aggregates confirming to IS:383, maximum size of coarse aggregate not exceeding 25mm mixed in a batching and mixing plant as per approved mix design, transport to site laid to proper grade & camber, spreading the concrete with shovels, rakes, compacted using needle, sceed and plate vibrators and finished in continuous operation including provision of contraction and expansion, construction joints, applying debonding strips, primer, sealant, dowel bars, near approaches to bridge / culvert and construction joints, joint filler, separation memberance, sealant primer, joint sealant primer, joint sealant, debonding strip, dowel bar , tie rod, admixture as approved as per the direction of Engineer-in-charge.
28Soiling road surface with soiling stone including fillup the interstices of requisite type of screening/binding materials and and rolling with 3-wheeled steel 8-10tonnes roller but excluding cost and conveyance of soiling stone.
29Providing & laying sub-base with moorum sand admixture (Moorum 70% sand 30%) in layers not exceeding 22.5cm thick in each layer watering and compaction to the required density in O.M.C. with PRRPer 1 cum
30Laying Cross Drainage System in Road(Hume Pipe Culvert)
31Earth work in excavetion of foundation trenches in hard soil
32Filling foundation and plinth with excavatedmaterials 2/3rd Quantity of above.
33Providing and laying piain cement concrete (1:3:6) using 40 mm and down graded size black hard crusher broken granite metal.
34Rigid and smooth centering and shuttering for R.C.C works including false works and dismantling them after casting including cost of materials complete in ground floor
35Providing and laying plain cement concrete of proportion (1:2:4) using 12 mm size black hard crusher broken granite chips .
3616 mm thick cement plaster (1:6) to the surface of cement concrete walls.
37Supplying & Laying 900mm dia R.C.C. NP4 standard Hume pipes in proper line and level .
38Supplying & Laying 600mm dia R.C.C. NP4 standard Hume pipes in proper line and level .
39Cement Washing two coats over plastered surface etc. Complete.
40Road Side Greenary & Social Forestry
41Earth work in excavation of pits
42Supply of Mini Tagar(3\")plant well grown healthy & disease free & planting site with required good soil & manure including transportation loading & unloading & watering as per requirement as per direction of EIC.
43P.C.C (1:3:6) Using 40 mm H.G (Hard granite ) metal in foundation.
44Providing M-20 Concrete using 20mm down graded HBG chips of approved Quality etc complete.
45providingBending binding Tor rod forR.C.C Works using Fe500 TMT bars.
46Centering & Shuttering of R.C.C Works .
472 Ply Birbered wire fencing
48Labour for fixing barbed wire fencing and post by means of staples and straining hooks by means of tying with G.L wire and including cost of staples, hooks and tying wires
49Maintenance of plants for six months (180 days) Labour 4 nos per day
50Watering by Tanker for 3 months @ 2 Tankers per day @ 500.00 Per Tanker
51Drainage
52Earth work in hard soil or gravelly soil within 50m. Intial lead and 1.5m initial lift including rough dressing and breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3m in depth and as per the direction of the Engineer-in-charge.
53Supplying & fillingfoundation and plinth with sand well watered & rammed etc. Complete.
54P.C.C (1:3:6) Using 40 mm H.G (Hard granite ) metal in foundation.
55Providing M-20 Concrete using 20mm down graded HBG chips of approved Quality etc complete.
56providingBending binding Tor rod forR.C.C Works using Fe500 TMT bars.
57Centering & Shuttering of R.C.C Works .
58Filling Foundation & Plinth with excavated earth.
59Providing, suppyling, conveyingand soling Berm road surface with soling stones including filling the interstices with good quality fitting materials and rolling with HRR.(Per 1 cum)
60Adminstrative & Other Service Complex
61Scraping old paint with scrapers, sand papering & washing with soap water or soda upto 5.00 Mtr. Height including cost of all materials required for the work, all labour, T&P, sundries, scaffolding etc. complete, as per the direction of the Engr. In Charge.
62Paintingto outside walls with 2 coats of weather coatpaint etc complete.
63Ground Floor Area
64First Floor Area
65Second Floor Area
66Boundary Wall
67Painting two coats withplastic emulsion paint over a coat of water bound wall primer to internal surface of plastered walls.
68Ground Floor Area
69First Floor Area
70Second Floor Area
71M.S.Window Grill made out of M.S.flat conforming to IS:2062/2006, painted with red oxide primer as per the design approved by the purchaser.
72Painting 2coats to old M.S.Grill and gates with synthetic enamail paint .
73Providing Supplying,diluting & spreading chemical emulsion ( imida cloprida ) for anti termite treatment (Post - Construction).
74Providing,Fitting and fixing of storage cabinet of ply portion of 450mm depth with required numbers of draws using 19mm BWP ply with 1mm both side lamination etc.complete.
75Ground Floor Area
76First Floor Area
77Telecom/Cyber/Documentation Centre
78Brick work with Flyash bricks of 25cmX12cmX8cm having crushing strength not less than 75 kg/cm² with dimensional tolerance +2 percent in cement mortar (1:4) in foundation.
7912mm thick cement plaster (1:4) over brick with cement punnig for skirting
8016mm thick cement plaster (1:6) over brick or stone masonry
81Fixing tiles in floors, treads or steps and landing over 25mm bed of C:M (1:1) jointed with neat cement slurry mixed with pigment to match the shade of the tiles including rubbing and polishing complete excluding the cost of pre-cast tiles
82Fixing tiles in dados, skirting and risers of steps on 12mm C:P (1:3) jointed with neat cement slurry mixed with pigment to match the shade of the tiles including rubbing and polishing complete excluding cost of precast tiles.
83Finishing plastered surfaces of walls withputty (interior wall puty)wall putyand making smooth to receive painting.
84Painting two coats withplastic emulsion paint over a coat of water bound wall primer to internal surface of plastered walls.
85Paintingto outside walls with 2 coats of weather coatpaint etc complete.
8628mm wood-plastic Composite Shutter moulded penelled with all labour, iron fitting and wooden hinged cleats fitted & fixed complete in all respect but excluding the cost of Iron fittings.
87Providing & Fixing of Storage Cabinet ofPly Portion of 450mm depth with required number of draws using 19mm BWP Ply with 1mm both side lamination
88Conference Hall/Exhibtion Centre
89CIVIL WORK
90Brick work with Flyash bricks of 25cmX12cmX8cm having crushing strength not less than 75 kg/cm² with dimensional tolerance +2 percent in cement mortar (1:4) in foundation.
9112mm thick cement plaster (1:4) over brick with cement punnig for skirting
9216mm thick cement plaster (1:6) over brick or stone masonry
93Providing, fitting and fixing ofgrid less ceilling with12.5mm thick gypsum Boardfix to frame comprises of G.I perimeter channels having 0.5mm thickness ,to unequal flanges of 20mm and 30mm web of 27mm is fix to surrounding walls , partitions using nylon sleeves and screws at 450mm centers .then inermidiate channel o.91mm thick having to equal flanges of 15mm each and web of 45mm is supended from the soffit at 1200mm center with ceilling angle of width 25mmx10mm x0.5mm thick fix to soffit with G.I cleat and steel expansion fasteners .Celling section of 0.5 mm thick having callweb of 50.5mm and flanges of26mm each with lips of 10.5mm are then fix to the intermidiate channel with connecting cleps across to the intermidiate channel at 600 /450 mm center .Boards are then screws fixed along /across the ceilling section with 25mm long self drilling and tapping screws having phillips head at 200mm C/C.The joints of face boards are finished with spcilly formulated jointing compound and 48mm wide fiber tape to provied sem less finish complete as per approved drawings including cost, conveyance, loading, unloading,stacking,of all Materials, cost of all Labour, Sundries and T&P, etc. required for the workexcuding GST as directed by the Engineer-in-charge
94Providing fitting and fixing Armstrong false ceiling with aluminium anodised T Section No.3215 with 2\"-0\" centre to centre,L section No. 1705 up to 15 micron on 4 walls to be fixed by means of steel screw and P.V.C plug and the Aluminium grid 2\" X 2\",susp
95Painting two coats withplastic emulsion paint over a coat of water bound wall primer to internal surface of plastered walls.
96Providing & Fixing ,in position concealed G.I. Section for wall paneling using board of required thickness fixed on the \"W\" profile (0.55mm thick) having a knurled web of 51.55mm and two flanges of 26mm each with lips of 10.55mm,placed @610mm C/C in perimeter channel having one flange of 20mm and another flange of 30mm with thickness of 0.55mm and web length 27mm.Perimeter channel is fixed on the floor and the ceiling with the nylon sleeves @610mm C/C with fully threaded self-tapping dry wall screws.Board is fixed to the W profile with 25mm countersunk EIC ribbed head screws @200 mm C/C.all complete as per the drawing and directions of EIC,the joints of board are specially formulated jointing compound and 48mm wide jointing tape to provide seamless finish.
97FURNITURE
98PVC Window vertical Blind for office of 2mm thickness with powder coated finishing -4Nos
99Designed bold printed Door Curtain of polyster material providesfull coverge to the door-1Nos
100Podium Made of MDF with 1 Drawer & Shelf with wallnut Polish
1011 Seater Soffa Material-Wooden Frame,Leatherite Covering with High Density Foam in Back and Seat & Wooden Handle
102Centre Table Made of MDF with 5mm thick toughned glass and shelf
103Confference Room TableSize-10\"X3\"X2\"6\"Table Top made with rubber wood,Table Top Thickness of 18mm,with 2 flipbox
104Highback Chair,Wooden Frame
105Student/Training Room Chair,PU Arm,PLPB Folding Writing Pad,Book Trey under Seat,Powder Coated pipe frame,Fabric Tasry Marino 10002 top colour
106Providing & Fixing of Storage Cabinet ofPly Portion of 450mm depth with required number of draws using 19mm BWP Ply with 1mm both side lamination
107PH Work
108Supplying all material,Labour,and T& P for White glazed viterious China Wash hand Basin of Size 550X400mm with Pedestal as per CAT No 10100 and 11003 0f Hindware
109Providing all Material labour and T& P for Laying joint UPVC Sch-80 as per ASTM D-1785
11020mm Nominal Diameter UPVC Pipe
11115mm Nominal Diameter UPVC Pipe
112Provising all materials labour and T& P For Fixing of C.P Pillar Cock (Make= Hindware)
113Bevelled Edge Mirror 600mm X450mm
114Providing & Fixing of 110mm dia PVC Swr Pipe & Fittings
115100MM dia PVC SWR pipe
116100mm dia PVC door Bend
117100MM Dia Single Tee With Door
118100MM Dia PVC Cowl
119P Trap
120Fixing Rotational moulded polyethylene cylindrical vertical water storage tanks conforming to IS : 12701--1996 including cutting holes through the tank and fixing mild steel tubes and fittings and providing extra sockets and jam nuts, fixing ball valve etc Including hoisting up to a height of 5mtr above Ground Level and Placing The Tank to the Required Position etc all complete as per direction of EIC
121Providing all Material labour and T& P for Laying joint UPVC Sch-80 as per ASTM D-1785
12240mm Nominal Diameter UPVC Pipe
12325mm Nominal Diameter UPVC Pipe
12420mm Nominal Diameter UPVC Pipe
12516mm Nominal Diameter UPVC Pipe
12650 mm Nominal Diameter UPVC Pipe
127Supplying all material,Labour,and T& P for White glazed viterious China Wash hand Basin of Size 550X400mm with Pedestal as per CAT No 10100 and 11003 0f Hindware
128Provising all materials labour and T& P For Fixing of C.P Pillar Cock (Make= Hindware)
129Providing Fittiing fixing 1145mmX510mmX200mm Steel Sink with Complete Set including all fitting(Nirally make)
130Providing & Fixing of 110mm dia PVC Swr Pipe & Fittings
131110MM dia PVC SWR pipe
132110mm dia PVC door Bend
133110MM Dia Single Tee With Door
134110MM Dia PVC Cowl
135P Trap
136Providing Fixing CP Sink Cock(Make=Jaguar) Cat No.FLR5357M
137Electrical Work
138Circuit Cum Wiring
139Supplying & Wiring for light point/ fan/ exhaust fan point/ call bell point with 1.5 sqmm FR PVC insulated copper conductor single core cable in surface / recessed 1.6 mm thick PVC conduit with modular switch and earthing the point with 1.5 sqmm FRLS PVC insulated copper conductor single core cable including providing modular box with cover of requisite number of modules including providing cover plates as required.
140Single light point controlled by one 6A switch or first light point of group control.
141Subsequent point of group control
142Supplying and fixing two module steeped type electronic fan regulator with proper modular plate switch box including connections etc. as required.
143Supplying and fixing 6 Amp plug with 6 Amp switch (Modular Type) on existing switch board.
144Supplying & fixing suitable size GI Box withmodular plate and cover in front on surface or in recess, including providing and fixing 3pin 5/6 amps modular socket outlet and 5/6 amps modular switch etc. as required.
145Supply, installation, testing & commissioning of 6 / 16 Amp Plug Boards consisting of a 16 Amp clip-in type modular switch with indicator and a 6/16 Amp clip-in type modular shuttered plug socket fixed on metallic concealed box including interconnections and making good the damages caused complete as required and as per direction of Engineer-in-charge.
146Supplying, installation, testing & commissioning of 20 Amp AC starter switch with 20 Amp modular socketoutlet with 25 Amp Plug on surface or in recess, on 2 Nos two module GI box with plate etc. complete with direction of Engineer-in-charge. Starter-Crabtree(cat no-ACTO202504) or equivalent.
147Wiring for circuit/ submain wiring along with earth wire of following size of FRLS heavy gauge PVC insulated copper conductor single core cable in heavy duty PVC conduit laid in surface/ recess as required.
1482X2.5 + 1X2.5 sqmm FRLS Cu wire
1492X4 + 1X2.5 sqmm FRLS Cu wire
1502X6 + 1X2.5 sqmm FRLS Cu wire
151Fan & indoor Fixtures
152Supply, delivery and fixing of Ceiling fan hookbox made out of 18 swg GI sheet and containing 10 mm dia round ms bar projecting atleast 150mm on either side & duly bent to accommodate ceiling fan down rod bolt & having earthing arrangement as per direction of Engineer-in-charge.
153Supplying, installation, testing and commissioning following type of light fixture with all other accessories, as required.(The colour temprature shall be between 3500 deg K as per application).
154Fully diffused type recessed mounted 2\"X2\" LED fitting (4000 Lumen/ 36W)similar to PHILIPS (CAT No:RC380B LED36S- 6500 G6 L60W60 PSU OD) / Equivalent of Bajaj/ Wipro.
155Fully diffused type surface mounted 2\"X2\" LED fitting (4000 Lumen/ 36W)similar to PHILIPS (CAT No:SM36XC LED32- 6500 PSU ODWH) / Equivalent of Bajaj/ Wipro.
156Fully diffused type recessed mounted 1/2\"X1/2\" LED fitting (2000 Lumen/ 18W)similar to PHILIPS (CAT No:DN177 18S LED DL G2 (CDL) / Equivalent of Bajaj/ Wipro.
157Fully diffused type surface mounted 1/2\"X1/2\" LED fitting (2000 Lumen/ 18W)similar to PHILIPS (CAT No:SM261C LED20S- 6500 PSU WH / Equivalent of Bajaj/ Wipro.
158Retail Down round type LED Light surface fitting (2000 Lumen/ 18 W)similar to PHILIPS (CAT No:DN296B LED20S-6500 PSE WH S1+ frame) / Equivalent of Bajaj/ Wipro.
159Commercial Batten type wall or surface mounted 4\" LED fitting (4000 Lumen/ 36W)similar to PHILIPS (CAT No:BN100C LED40S-6500 PSU L120 GR S4) / Equivalent of Bajaj/ Wipro.
160Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required.
161Supplying, installation, testing and commissioning of ceiling fan (5 star rating) including wiring the down rod, earthing etc as required (Make : Bajaj/Usha/ Crompton/ Orient/ Khaitan/ Havells).
1621200 mm sweep
163Supplying, installation, testing and commissioning of wall mounted fan (5 star rating) including earthing etc as required (Make : Bajaj/Usha/ Crompton/ Orient/ Khaitan/ Havells).
164400 mm sweep 1300 RPM
165Supplying, installation, testing and commissioning of Heavy Duty Exhaust fan (5 star rating) including louvres, Ceiling Rose & Electric Connection asrequired. (Make -Bajaj/Usha/ Crompton/ Orient/ Khaitan/ Havells)
166300mm sweep 900 RPM
167Air Conditioning
168Supply, Installation, Testing and commissioning of HIWALL inverter split air conditioning units with copper condenser & back to back with 5Rmt of copper piping, complete with centrifugal fan, multirow cooling coil, drive motor, casing, drain pan,filters etc., with matching air cooled condenser with Scroll /Reciprocating compressor, air-cooled condenser fans, casing, first charge of gas ( R407C/R410A), microprocessor control, mounting frames, Safety controls,cabling between indoor and outdoor units etc. Units are included with all Refrigeration Controls like thermostatic Expansion valve, Solenoid valve,inbuilt stabilizer and drain piping to the nearest drain point as per specifications (5- Star Rated). (Make- Voltas/ Carrier/ Daikin)
1691.5 TR
1702 TR
171Audio Visual
172Supply, installation, testing & commissioning of Articulated Array® design provides wide 175° x 90° coverage to deliver wide-range reproduction over a broad dispersion area, Two-way design with 5.25\" (133 mm) woofer and two 2.5\" (64 mm) drivers for extended, smooth response, Frequency range down to 60 Hz allows full-range speech and light music reinforcement without the need for subwoofers in many applications, Integrated multi-tap line transformer for 70 V or 100 V applications, Included mounting hardware permits fast and easy installation, Frequency Response (+/-3 dB)1- 75 Hz - 16 kHz,Frequency Range (-10 dB)1-60 Hz - 19 kHz,Nominal Dispersion--175° H x 90° V Recommended High-Pass Filter - 65 Hz high-pass filter,Long-Term Power Handling2-100 W (400 W peak),Sensitivity (SPL / 1 W @ 1 m)3-82 dB SPL,Maximum SPL @ 1 m4-102 dB SP. (Make: Bose/ Meyer or equivalent)
173Supply, installation, testing & commissioning ofLive 1x 250W Ampliferwith In built DSP Complete with FIR Filters, Audio Limiters, Output delay per channel, 31 band GEQ per channel, PEQ per channel, Load impedance and having PC remote control option. (Make: Bose/JBL or equivalent)
174Supply, installation, testing & commissioning of 10-Channel Mixing Console: Max. 4 Mic / 10 Line Inputs (4 mono + 3 stereo) / 1 Stereo Bus / 1 AUX (incl. FX),“D-PRE” mic preamps with an inverted Darlington circuit,1-Knob compressors,High-grade effects: SPX with 24 programs,24-bit / 192kHz 2in / 2out USB Audio functions,Works with the iPad (2 or later) through the Apple iPad Camera Connection Kit / Lightning to USB Camera Adapter,Includes Cubase AI DAW software download version,PAD switch on mono inputs,+48V phantom power. (Make: Yamaha/Dynacord or equivalent)
175Supply, installation, testing & commissioning of Condenser Gooseneck Microphone-Multi-pattern desktop microphone,Frequency Response (-3 dB) 50 - 20,000 Hz,Family Polar Choice,Power Requirement 12 - 52 VDC,Polar Pattern Omni, Cardioid, S-cardioid & H-cardioid,Wired/Wireless Wired,Mic Type Gooseneck,Diameter (Max) 0.25\" (6.4mm). (Make : Electro Voice/ Shure or equivalent)
176Supply, installation, testing & commissioning ofProjector of WXGA (1280x800),DLP, 4000 Lumens High Brightness, 22000:1 High Contrast Ratio, Dual HDMI, Upto 15000 hrs Extra-Long Lamp Life, 10W Speaker, 3D Capable,Throw Ratio-1.55~1.7,Zoom Ratio-1.1x,Lens-F/# = 2.56 ~ 2.68, f = 22 ~ 24.1 mm,Projection Offset (Full-Height)-100%,Keystone Adjustment-1D, Vertical ± 40 degrees along with ceiling mount for projector. (Make: Benq/ Epson/Sony or equivalent)
177Supply, installation, testing & commissioning ofMotorized Projetion Screen of Size 5\" X7\" along with all accessories . (Make: Suvira or equivalent)
178Supply & laying of Loudspeaker Cable along with PVC Conduit.(Make: Krystal or equivalent)
179Supply, installation, testing & commissioning ofHDMI cableof appropiate size including all connectors & accessories.
180Supply, installation, testing & commissioning of12U Rack for Controller & Amplifier.
181First Aid Centre,Creche Canteen
182CIVIL WORK
183Dismantling B.M. in cement mortar under 3mtr height including stacking the useful materials for re-use & removing the debries away from work site within 50mtr lead
184Dismantlling and removing doors windows and ventilators including removal of frame, hinges fastening and stacking the same for re-use and removing the debries within 50mtr lead
185Dismantlling and removing old tiled flooring including removing the base coarse and stacking the useful materials for re-use and removing the debries within 50mtr lead
186Dismantling Steel Work in all types of sections upto a height of 5 m above plinth level including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all li
187Filling in foundation and plinth with sand watered and rammed
188Cement concrete (1:3:6) with 4cm size hard broken granite chips
189Brick work with Flyash bricks of 25cmX12cmX8cm having crushing strength not less than 75 kg/cm² with dimensional tolerance +2 percent in cement mortar (1:4) in foundation.
19012mm thick cement plaster (1:4) over brick with cement punnig for skirting
19116mm thick cement plaster (1:6) over brick or stone masonry
192Fixing tiles in floors, treads or steps and landing over 25mm bed of C:M (1:1) jointed with neat cement slurry mixed with pigment to match the shade of the tiles including rubbing and polishing complete excluding the cost of pre-cast tiles
193Fixing tiles in dados, skirting and risers of steps on 12mm C:P (1:3) jointed with neat cement slurry mixed with pigment to match the shade of the tiles including rubbing and polishing complete excluding cost of precast tiles.
194Finishing plastered surfaces of walls withputty (interior wall puty)wall putyand making smooth to receive painting.
195Painting two coats withplastic emulsion paint over a coat of water bound wall primer to internal surface of plastered walls.
196Paintingto outside walls with 2 coats of weather coatpaint etc complete.
19728mm wood-plastic Composite Shutter moulded penelled with all labour, iron fitting and wooden hinged cleats fitted & fixed complete in all respect but excluding the cost of Iron fittings.
198RAJSHRI PLASTIWOOD UPVC Window 2.5 - Track UPVC (UnplasticizedPolyvinyl Chloride) Window, Length 6 Foot RAJSHRI PLASTIWOODR (SLIDING UPVC WINDOW 2 - TRACK SIZE 6 X 4 ft.)
199Painting 2coats to old M.S.Grill and gates with synthetic enamail paint .
200Furnitures
201Executive Table Size-1800mm X 900mm X 750mmwith drawers mobile pedstal & size side table table Top thickness-75mm
202Medium Back Chair,Pipe Frame,PU Chrome Arm,Gas Lift,Chrome Base,Leatherite Tapestry
2033 Seater SoffaMaterial-Wooden Frame,Leatherite covering with high density foam in back and seat & wooden Handle
204Patient Couch Size -78\" X 24\"X30\"Made of MS Pipe & 2\"Foam matress with rexine matress size 75\"X 30\"Notes: Black Rexine foam matress Ivory Colour MS Pipe All Squre pipe
205Kitchen
206Earth work in oridinary soil within 50m, initial lead and 1.5m, initial lift including rought dressing and breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3m in depth and as per direction of Engineer-in-charge
207Filling in foundation and plinth with sand watered and rammed
208Filling in foundation and plinth with excavated materials including watering and ramming as directed by the Engineer-in-charge for 100 cum
209Cement concrete (1:3:6) with 4cm size hard broken granite chips
210R.C.C Work of M-20 grade with 20mm and down grade black hard granite(Crusher broken) stone chips including hoisting and laying.
211Supplying, fitting and placing uncoated HYSD bar reinforcement complete as per drawing and technical specification.
212Brick work with Flyash bricks of 25cmX12cmX8cm having crushing strength not less than 75 kg/cm² with dimensional tolerance +2 percent in cement mortar (1:4) in foundation.
213Brick Massonary Work For Supper Structure
21412mm thick cement plaster (1:6) over brick or stone masonry
21516mm thick cement plaster (1:6) over brick or stone masonry
216Fixing tiles in floors, treads or steps and landing over 25mm bed of C:M (1:1) jointed with neat cement slurry mixed with pigment to match the shade of the tiles including rubbing and polishing complete including the cost of pre-cast tiles
217Finishing wall surface of wall with Acrylic wall putty(water based) of approved make and finished smooth and even surface to receive painting including cost of scaffolding staging charges with cost of all materials taxes,labour T&P etc complete.
218Painting two coats withplastic emulsion paint over a coat of water bound wall primer to internal surface of plastered walls.
219Paintingto outside walls with 2 coats of weather coatpaint etc complete.
22028mm wood-plastic Composite Shutter moulded penelled with all labour, iron fitting and wooden hinged cleats fitted & fixed complete in all respect but excluding the cost of Iron fittings.
221RAJSHRI PLASTIWOOD UPVC Window 2.5 - Track UPVC (UnplasticizedPolyvinyl Chloride) Window, Length 6 Foot RAJSHRI PLASTIWOOD (SLIDING UPVC WINDOW 2 - TRACK SIZE 6 X 4 ft.)
222M.S.Window Grill made out of M.S.flat conforming to IS:2062/2006, painted with red oxide primer as per the design approved by the purchaser.
223N.B.:- GST as applicable will be paid extra.

AI Tender Summary

OUR REF NO 32808663
AUTHORITY Government Departments
TENDER VALUE 3.87 Crore
LAST DATE 11-07-2022
Authority
Authority Name Orissa Industrial Infrastructure Development Corporation
Work Description Up-Gradation Of Industrial Estate, Jagatpur, Cuttack, Odisha Under Micro And Small Enterprises Cluster Development Programme (Mse-Cdp) Scheme.
Basic Detail
Tender No PC/EST/E-23/2022-23
Bidding Type Tender
Location
City jagatpur
State Odisha
Key Dates
Publish Date 24 Jun 2022
Submission Date 11 Jul 2022
Open Date 12 Jul 2022
Finance
Tender Value 3.87 Crore
Tender Fee 11800
EMD Ref. Documents
Exemption Not Available
Document List
0dce099e-79cd-4189-b39b-59e4ca6a503c.html
BOQ_403480.xls
DTCN.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jun 24, 2022
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 11, 2022
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Jul 12, 2022

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

0dce099e-79cd-4189-b39b-59e4ca6a503c.html

xls

BOQ_403480.xls

pdf

DTCN.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail