}

Tender for Supply of equipment / material , design, erection, testing & commissioning for SOP to Indian Meteorological Departmentby Prov. 11/.4 KV 63 KVA S/Stn. a/w 11 KV HT and LT line for Doppler WeatherRaddar at Vill. Jotin section Chowari-I under ESD , Chamba-Himachal Pradesh

Himachal Pradesh State Electricity Board-HPSEB has published Tender for Supply of equipment / material , design, erection, testing & commissioning for SOP to Indian Meteorological Departmentby Prov. 11/.4 KV 63 KVA S/Stn. a/w 11 KV HT and LT line for Doppler WeatherRaddar at Vill. Jotin section Chowari-I under ESD . Submission Date for this Tender is 01-07-2022. Coats and Jackets Tenders in Chamba Himachal Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

32805559
Tender for Supply of equipment / material , design, erection, testing & commissioning for SOP to Indian Meteorological Departmentby Prov. 11/.4 KV 63 KVA S/Stn. a/w 11 KV HT and LT line for Doppler WeatherRaddar at Vill. Jotin section Chowari-I under ESD
Open Tender
Indian
Himachal Pradesh
Chamba
01-07-2022

Tender Details

Tender for Supply of equipment / material , design, erection, testing & commissioning for SOP to Indian Meteorological Departmentby Prov. 11/.4 KV 63 KVA S/Stn. a/w 11 KV HT and LT line for Doppler WeatherRaddar at Vill. Jotin section Chowari-I under ESD Chowari ED Dalhousie ( T.S. No. 232/21-22 )(BID No. OCD/DB/Bid-23/2022-23) Sl. No. Item Description 1 Supply of 11/.4 KV 63 KVA DISTRIBUTION SUB STATION 2 11/.4 KV 63KVA DTR (REC Sep. ord 11/1976 3 Prov. ST PolePole 9 Mtr. Long W/L 200 Kgs 4 Muff for steel tubular pole with concrete filling 5 X-Arm: [Channel Iron (100x50x5 mm), Length : 2800 mm X 2 Nos] for incomer line 6 MS A.I.(50X50x6 mm), Length: 2800 mm x(1 Nos for LAs ) 7 X-Arm: [Channel Iron (75x40x5 mm), Length : 2800 mm X 4 Nos] for supporting DO fuse unit & GO switch 8 X-Arm: [Channel Iron (100x50x6 mm), Length : 2800 mm X 2 Nos] for transformer bed 9 X-Arm [Channel Iron (100x50x6 mm), Length : 460 mm x 2 Nos for supporting Main Channel of Transformer] 10 MS A.I.(50X50x6 mm), Length: (2800 mm) x 2 No. 11 MS Angle Iron (35X35x5 mm), Length : 460 mm x 2 Nos 12 MS A.I.(50X50x6 mm), Length: (950 mm) x 2 Nos. of bed knee bracing 13 MS Angle Iron (50X50x6 mm), Length : (2800 mm) x2 Nos for Transformer LT Distribution Box and G.O switch fixing assembly 14 MS Angle Iron (50X50x6 mm), Length : (450 mm)x1 Nos for Transformer LT Distribution Box and G.O switch fixing assembly 15 G.O. Switch handle supporting: [C.I. (75x40x6mm), length: 460mm for Transformer LT Distribution Box and G.O switch fixing assembly 16 G.O AB switch unit (11KV,400,663KA) Tripple pole O/D type 17 D.O Fuse unit 18 Surge Arrester, 9 kV Station Class 19 Discs insulator sets (comp. 1 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) i/c Dead End Clamps etc.) 20 Stay set complete 21 Staywire (7/3.15mm)( 7 Kg per stay set) 22 Pipe earthing with GI,Charcoal & Salt 23 Prov. LT distribution panel with MCCB (40 A, 36 KA, 4P,1 No.) & SFU (16A 4 No. rewireble) for 63KVA Trf. as per specification 24 Half clamp (M.S. Flat 50x6) 25 Full clamps (M.S. Flat 50x6) 26 M. S. Nuts & Bolts off sizes (Galvanised coated) [prefarably 16mm Ø or more (with flat and spring washer) 27 Aluminium Thimbles 28 Copper Thimble 29 Danger Plate 30 Barbed wire (REC Sp F 3/1981) 31 LT Cable 3-1/2 core-120mm sq. 32 Alluminium Paint 33 Prov.ACSR, 6/1/3.35 mm 34 Prov. Transformer structure protection plinth(Civil Work As per HPSR) for 63KVA S/Stn 35 Erection of 63 kVA S/Stn 36 11/.4 KV 63KVA DTR (REC Sep. ord 11/1976 37 Prov. ST PolePole 9 Mtr. Long W/L 200 Kgs 38 Muff for steel tubular pole with concrete filling 39 X-Arm: [Channel Iron (100x50x5 mm), Length : 2800 mm X 2 Nos] for incomer line 40 MS A.I.(50X50x6 mm), Length: 2800 mm x(1 Nos for LAs ) 41 X-Arm: [Channel Iron (75x40x5 mm), Length : 2800 mm X 4 Nos] for supporting DO fuse unit & GO switch 42 X-Arm: [Channel Iron (100x50x6 mm), Length : 2800 mm X 2 Nos] for transformer bed 43 X-Arm [Channel Iron (100x50x6 mm), Length : 460 mm x 2 Nos for supporting Main Channel of Transformer] 44 MS A.I.(50X50x6 mm), Length: (2800 mm) x 2 No. 45 MS Angle Iron (35X35x5 mm), Length : 460 mm x 2 Nos 46 MS A.I.(50X50x6 mm), Length: (950 mm) x 2 Nos. of bed knee bracing 47 MS Angle Iron (50X50x6 mm), Length : (2800 mm) x2 Nos for Transformer LT Distribution Box and G.O switch fixing assembly 48 MS Angle Iron (50X50x6 mm), Length : (450 mm)x1 Nos for Transformer LT Distribution Box and G.O switch fixing assembly 49 G.O. Switch handle supporting: [C.I. (75x40x6mm), length: 460mm for Transformer LT Distribution Box and G.O switch fixing assembly 50 G.O AB switch unit (11KV,400,663KA) Tripple pole O/D type 51 D.O Fuse unit 52 Surge Arrester, 9 kV Station Class 53 Discs insulator sets (comp. 1 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) i/c Dead End Clamps etc.) 54 Stay set complete 55 Staywire (7/3.15mm)( 7 Kg per stay set) 56 Pipe earthing with GI,Charcoal & Salt 57 Prov. LT distribution panel with MCCB (40 A, 36 KA, 4P,1 No.) & SFU (16A 4 No. rewireble) for 63KVA Trf. as per specification 58 Half clamp (M.S. Flat 50x6) 59 Full clamps (M.S. Flat 50x6) 60 M. S. Nuts & Bolts off sizes (Galvanised coated) [prefarably 16mm Ø or more (with flat and spring washer) 61 Aluminium Thimbles 62 Copper Thimble 63 Danger Plate 64 Barbed wire (REC Sp F 3/1981) 65 LT Cable 3-1/2 core-120mm sq. 66 Alluminium Paint 67 Prov.ACSR, 6/1/3.35 mm 68 Prov. Transformer structure protection plinth(Civil Work As per HPSR) for 63KVA S/Stn 69 Supply of 11 kV HT line 70 ACSR 6/1/3.35 (55mm²) {Includes 3 conductor lengths for 3F and Additional 1% (Sag, Jumpering and wastage} 71 Prov. Steel tubular poles. 9mtrs 72 Muff for steel tubular pole (2000mm long) with concrete filling 73 Belt Set - MS Angle Iron: 50x50x6, Length [1800 mm x 2 No.]for Dead End Structures 74 X-Bracing Set - MS Angle Iron: 50x50x6, Length [2125 mm x2 No.] for Dead End Structures 75 X-Arm(Horizental) - MS C. Iron: 50x50x6, Length [2340 mm x2 No.]for Dead End Structures 76 Discs insulator sets on Dead End structures (comprising 1 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) including Dead End Clamps etc.) x (3 No. conductors) x (2 No. sides)for Dead End Structures 77 11 kV Pin Insulators (Porcelain, 12 kV, 10 KN): 3 No per pole structure for Dead End Structures 78 Stay set complete in all respect ( Single Pole-1No. , /D. Pole Structures-4Nos.) 79 Stay Wire (7/3.15 mm) (8.0 kg Per Stay Set) 80 Single Continous Earth wire (GI, 8 SWG) {alongwith 1 wire lengths for avg. one road crossing @ 20 m and Additional 1% (Sag and wastage)} @ 0.102 kg/m 81 Eye Hook for earth wire 82 Earth Wire Clamp 83 MS Chanel Iron 75x40x6mm, length: 2400mm for road crossing/G.O Switch 84 Half clamp (on D/P dead end str:4Nos; on Run Through Str. 2Nos.) 85 Full clamp (on D/P dead end str:4Nos; on Run Through Str. 2Nos.) 86 Danger Plate (250X200X1.6 mm) 87 M. S. Nuts & Bolts off sizes (Galvanised coated) [prefarably 16mm Ø or more (with flat and spring washer) 88 Barbed wire (REC Sp F 3/1981) 89 G.O AB switch unit (11KV,400,663KA) Tripple pole O/D type 90 Alluminium Paint 91 Erection of 11 kV HT line 92 ACSR 6/1/3.35 (55mm²) {Includes 3 conductor lengths for 3F and Additional 1% (Sag, Jumpering and wastage} 93 Prov. Steel tubular poles. 9mtrs 94 Muff for steel tubular pole (2000mm long) with concrete filling 95 Belt Set - MS Angle Iron: 50x50x6, Length [1800 mm x 2 No.]for Dead End Structures 96 X-Bracing Set - MS Angle Iron: 50x50x6, Length [2125 mm x2 No.] for Dead End Structures 97 X-Arm(Horizental) - MS C. Iron: 50x50x6, Length [2340 mm x2 No.]for Dead End Structures 98 Discs insulator sets on Dead End structures (comprising 1 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) including Dead End Clamps etc.) x (3 No. conductors) x (2 No. sides)for Dead End Structures 99 11 kV Pin Insulators (Porcelain, 12 kV, 10 KN): 3 No per pole structure for Dead End Structures 100 Stay set complete in all respect ( Single Pole-1No. , /D. Pole Structures-4Nos.) 101 Stay Wire (7/3.15 mm) (8.0 kg Per Stay Set) 102 Single Continous Earth wire (GI, 8 SWG) {alongwith 1 wire lengths for avg. one road crossing @ 20 m and Additional 1% (Sag and wastage)} @ 0.102 kg/m 103 Eye Hook for earth wire 104 Earth Wire Clamp 105 MS Chanel Iron 75x40x6mm, length: 2400mm for road crossing/G.O Switch 106 Half clamp (on D/P dead end str:4Nos; on Run Through Str. 2Nos.) 107 Full clamp (on D/P dead end str:4Nos; on Run Through Str. 2Nos.) 108 Danger Plate (250X200X1.6 mm) 109 M. S. Nuts & Bolts off sizes (Galvanised coated) [prefarably 16mm Ø or more (with flat and spring washer) 110 Barbed wire (REC Sp F 3/1981) 111 G.O AB switch unit (11KV,400,663KA) Tripple pole O/D type 112 Alluminium Paint 113 Supply of LT line 114 ACSR 6/1/3.35 mm sq. 115 Steel Pole 8Mtr. Long (1800mm long) 116 Muff for steel tubular pole 117 Shackle insulators (16KN) (RECD-3/761)(ISS No 1445/1977) 118 D-iron (U-Clamp) (RECD-4/79)(ISS No 7935/1975) 119 Earth Knob 120 LT Saty Set Complete With Satywire REC No 31/1983 121 Prov. Full clamp 122 Coil Earthing (spec J-1/72) 123 G.I.Wire No 8 SWG Earth wire1.03km (Sep.G-2/72) for suporting cable 124 Spool Tie 125 M.S.Nuts & Bolt off Sizes 126 Aluminium paint 127 Erection of LT line 128 ACSR 6/1/3.35 mm sq. 129 Steel Pole 8Mtr. Long (1800mm long) 130 Muff for steel tubular pole 131 Shackle insulators (16KN) (RECD-3/761)(ISS No 1445/1977) 132 D-iron (U-Clamp) (RECD-4/79)(ISS No 7935/1975) 133 Earth Knob 134 LT Saty Set Complete With Satywire REC No 31/1983 135 Prov. Full clamp 136 Coil Earthing (spec J-1/72) 137 G.I.Wire No 8 SWG Earth wire1.03km (Sep.G-2/72) for suporting cable 138 Spool Tie 139 M.S.Nuts & Bolt off Sizes 140 Aluminium paint

Key Value

Document Fees
INR 590 /-
EMD
INR 7716.0 /-
Tender Value
INR 7.71 Lakhs /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail