Project Description
Development Of Water Body, Treated Waste Water Distribution Network System And Allied Works At Nsut Main Campus ( Composite Work ) .
BOQ
| Sl. No. | Item Description |
| 1 | A. Treated Effluent Water Distribution Network1Excavating trenches manually only of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m- all kinds of soilPipes, cables etc. exceeding 80 mm dia. but notexceeding 300 mm dia |
| 2 | 2 Extra for excavating trenches manually only for pipes, cables etc. in all kinds of soil for depth exceeding 1.5 m, but not exceeding 3 m. (Rate is over corresponding basic item for depth upto 1.5 metre). |
| 3 | 3 Providing and laying S&S centrifugally cast (spun) ductile iron Pipes Conforming to IS – 8329a) 100 mm dia Ductile Iron Class K-7 pipes |
| 4 | b) 150 mm dia Ductile Iron Class K-7 pipes |
| 5 | c) 200 mm dia Ductile Iron Class K-7 pipes |
| 6 | d) 250 mm dia Ductile Iron Class K-7 pipes |
| 7 | e) 300 mm dia Ductile Iron Class K-7 pipes |
| 8 | 4 Providing and laying S&S C.I. standard specials such as tees, bends, collars, tapers, caps, Tail pieceetc. (Heavy class) upto 300mm dia |
| 9 | 5 Providing and laying S&S C.I. Standard specials such as tees, bends, collars tapers and caps etc, suitable for flanged jointing as per IS : 1538 :Up to 300 mm dia |
| 10 | 6 Providing/Fixing C.I S/V (with cap) complete with bolts, nuts, rubber insertion etc. (The tail piece if required will be paid separately)a) 100 mm diameterClass I |
| 11 | b) 150 mm diameterClass I |
| 12 | c) 200 mm diameterClass I |
| 13 | d) 250 mm diameterClass I |
| 14 | e) 300 mm diameterClass I |
| 15 | 7 Providing push on joints to centrifugally ( spun ) cast iron pipes or Ductile iron pipes i/c testing of joints and i/c the cost of rubber gasket.100 mm diaa) 100 mm dia pipes |
| 16 | b) 150 mm dia pipes |
| 17 | c) 200 mm dia pipes |
| 18 | d) 250 mm dia pipes |
| 19 | e) 300 mm dia pipes |
| 20 | 8 Constructing masonry Chamber 90x90x100 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ), i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S.(non modular) bricksof class designation 7.5 |
| 21 | 9 Constructing masonry Chamber 120x120x100 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design bricks of class designation 7.5 |
| 22 | 10 Installation of product pipe by Auger Boring method including making of entry and exit pits , all related civil works like excavation, shoring/strutting, etc, shielded excavation through auger boring process lowering of pipe segment in the jacking pit, laying and jointing of product pipeline through jacking process from the jacking pit and restoration of site after project complete except the cost of the pipe. (upto 100 meter installation length) method including making of entry and exit pits all related to civil works like excavation shoring /shuttering etc. shielded excavation through auger boring process restoration of sites after project completion as per the instruction of engineer-in- charge all complete except the cost of pipe. Note 1 : Cost of road cutting and reinstatement has been included in the rates. 2. Cost of lowering, laying and jointing of product pipe will be paid extra. 3. extra rates for making connection to existing lines are applicable. 4. for depth 7.5 Mtr. beyond the payment would be made extra.above 450 mm dia upto 600 mm dia |
| 23 | B. Development of Water Body.(i) Civil Works11 Earth work in excavation by manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. All kinds of soil. |
| 24 | 12 Excavating trenches manually only of required width for pipe, cables etc including excavation for sockets ,& dressing of sides ,ramming of bottoms ,for alldepthincluding getting out thed soil,& then returningthe soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc and disposingof surplus excavated soil as directed, within lead of 50m. All kinds of soil. Pipes, cables etc exceeding 80 mm dia but not exceeding 300 mm dia |
| 25 | 13 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size). |
| 26 | 14 Centering and shuttering including strutting, propping etc. and removal of form for :a Foundations, footings, bases of columns, etc. for mass concrete. |
| 27 | b Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. |
| 28 | c Suspended floors, roofs, landings, balconies and access platform |
| 29 | d Shelves (Cast in situ) |
| 30 | e Lintels, beams, plinth beams, girders, bressumers and cantilevers. |
| 31 | f Columns, Pillars, Piers, Abutments, Posts and Struts |
| 32 | g Stairs, (excluding landings) except spiral-staircases. |
| 33 | h Edges of slabs and breaks in floors and walls, under 20 cm wide |
| 34 | 15 Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc., including cost of de-shuttering and decentering at all levels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan area to be measured).Suspended floors, roofs, landing, beams and balconies (Plan area to be measured) |
| 35 | 16 Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars. |
| 36 | 17 Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level and upto floor V level.Thermo-Mechanically Treated bars. |
| 37 | 18 Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge.(Note :- Cement content considered in this item is @ 330 kg/cum. Excess/ less cement used as per design mix is payable/recoverable separately).a All works upto plinth level |
| 38 | b All works above plinth level upto floor V level |
| 39 | 19 Brick work with F.P.S. bricks of class designation 75 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 40 | 20 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 41 | 21 Half brick masonry with F.P.S. bricks of class designation 75 in superstructure above plinth level up to floor V level.Cement mortar 1:4 (1 cement :4 coarse sand) |
| 42 | 22 Extra for providing and placing in position 2 Nos. 6mm dia. M.S. bars at every third course of half brick masonry (with F.P.S. bricks). |
| 43 | 23 Providing and fixing 18mm thick gang saw cut mirror polished premoulded and prepolished) machine cut for flooring, staircase treads, risers and landings, kitchen platforms, vanity counters, window sills, facias and similar locations of required size of approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand) with joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edge to give high gloss finish etc. complete at all levels.Granite of any colour and shadeArea of slab upto 0.50 sqm |
| 44 | 24 Providing and fixing IS:3564 markedhaving brand logo with ISI embossed on the plate door weight 36 KG to 80 KG and door width from 701 mm to 1000 mm aluminium extruded section body tubular type universal hydraulic door closer with double speed adjustment with necessary accessories and screws etc. complete |
| 45 | 25 Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with necessary screws etc. complete :a 250x10 mm |
| 46 | b 150x10 mm |
| 47 | 26 Providing and fixing 50cm long aluminium kicking plate 100x3.15 mm anodised (anodic coating not less than grade AC 10 as per IS :1868) transparent or dyed to required colour or shade with necessary screws etc. complete. |
| 48 | 27 Providing and fixing aluminium handles ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete :a 125 mm |
| 49 | b. 100 mm |
| 50 | 28 Providing and fixing aluminium hanging floor door stopper ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade with necessary screws etc. complete.Twin rubber stopper |
| 51 | 29 Providing and fixing factory made shutters of Pre-laminated particle board flat pressed three layer or graded wood particle board with one side decorative finish and other side balancing lamination conforming to IS: 12823 Grade l Type ll, of approved design, and edges sealed with water resistant paint and lipped with aluminium \"U\" type edge beading allround the shutter, including fixing with angle cleat, grip strip, cadmium plated steel screws, including fixing of aluminium hinges 100x63x4 mm etc. complete as per architectural drawing and direction of Engineer-in- Charge (Cost of \"U\" beading and hinges will be paid for separately).25 mm thick |
| 52 | 30 Providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm all complete.With 12 mm uPVC or aluminumpowder coatedU beading |
| 53 | 31 Extra for providing frosted glass panes5 mm thick instead of ordinary float glass panes 5 mm thick in doors, windows and clerestory window shutters. (Area of opening for glass panes excluding portion inside rebate shall be measured). |
| 54 | 32 Providing and fixing POWDER COATED aluminum U beading of required size to Pre-laminated/ flush door shutter, including fixing etc. all complete as per the directions of Engineer-in-charge. |
| 55 | 33 Providing and fixing ISI marked powder coated aluminium butt hingestransparent or dyed to required colour or shade with necessary screws etc. all complete as per the directions of Engineer-in-charge.100x63x4 mm |
| 56 | 34Providing and fixing factory made uPVC white colour fixed glazedwindows/ventilators comprising of uPVC multi-chambered frame and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, G.I fasteners 100 x 8 mm size for fixing frame to finished wall,plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware\"s and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately).Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. Fixed window / ventilator made of (small series) frame 47 x 50 mm & mullion 47 x 68 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. (Area upto 1.0 sqm.) |
| 57 | 35Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thickalvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware\"s and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately) Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made.Three track three panels sliding window with fly proof SS wire mesh (Two nos. glazed & one no. wire mesh panels) made of (small series) frame 92 x 44 mm & sash 32 x 60 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension (Area of window upto 1.75 sqm). |
| 58 | 36 Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete :a300x16 mm |
| 59 | b 250x16 mm |
| 60 | 37 Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 61 | 38 Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 62 | 39 Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.80x1.25 mm M.S. laths with 1.25 mm thick top cover |
| 63 | 40 Providing and fixing ball bearing for rolling shutters. |
| 64 | 41 Extra for providing mechanical device chain and crank operation for operating rolling shutters.Exceeding 10.00 sqm and upto 16.80 sqm in the area |
| 65 | 42 Steel work welded in built up sections/ framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works. |
| 66 | 43 Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 67 | 44 Providing & fixing glass panes with putty and glazing clips in upvc windows, windows, clerestory windows, all complete with : 5 mm thick glass panes |
| 68 | 45 Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :25 mm Thick |
| 69 | 46 Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. |
| 70 | 47 Extra for Kota stone/ sand stone in treads of steps and risers using single length up to 1.5 metre . |
| 71 | 48 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of size 600 mm x300 mm or as decided / approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade all complete as per the directions of Engineer-in-charge. |
| 72 | 49 Providing and laying rectified Glazed Ceramic floor tiles of size 600 mm x 600 mm or as decided / approved by Engineer-in-charge (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc. all complete. |
| 73 | 50 Providing and fixing Glass mossaic tiles on finished plain wall surface of size 20 mm x 20 mm x 4 mm in all colour, design , fixing in customize design as per direction of Engineer-in- Charge. The glass mosaic tiles to be fixed on the wall surface with the help of approved adhesive applied at the rate of 2.5 kg per sqm and grouting of the same. The rate is inclusive of all operation, material and required pattern approved by Engineer-in-Charge: |
| 74 | 51 Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.11.56.1 Polished Granite stone slab jet Black, Cherry Red, Elite brown, Cat Eye or equivalent. |
| 75 | 52 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.110 mm diameter |
| 76 | 53 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.a Single tee without door110x110x110 mm |
| 77 | b Bend 87.5°110 mm bend |
| 78 | 54 15 mm cement plaster on the rough side of single or half brick wall of mix :1:4 (1 cement: 4 fine sand) |
| 79 | 55 6 mm cement plaster of mix : 1:3 (1 cement : 3 fine sand) |
| 80 | 56 Wall painting with acrylic emulsion paint of approved brand andmanufacture to give an even shade :Two or more coats on new work |
| 81 | 57 Finishing walls with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications :Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of Special primer applied @ 0.75 ltr / 10 sqm. |
| 82 | 58 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work on steel surface |
| 83 | 59 Providing and applying 12 mm thick (average) premixed formulated one coat gypsum lightweight plaster having additives and light weight aggregates as vermiculite/ perlite respectively conforming to IS: 2547 (Part - 1 & II) 1976, applied on hacked / uneven background such as bare brick/ block/ RCC work on walls & ceiling at all floors and locations, finished in smooth line and level etc. complete. |
| 84 | 60 Providing and laying design mix cement concrete of M-30 grade, in roads/ taxi tracks/ runways, using cement content as per design mix, using coarse sand and graded stone aggregate of 20 mm nominal size in appropriate proportions as per approved & specified design criteria, providing dowel bars with sleeve/ tie bars wherever required, laying at site, spreading and compacting mechanically by using needle and surface vibrators, levelling to required slope/ camber, finishing with required texture, including steel form work with sturdy M.S. channel sections, curing, making provision for contraction/ expansion, construction & longitudinal joints ( 10 mm wide x 50 mm deep) by groove cutting machine, providing and filling joints with approved joint filler and sealants, complete all as per direction of Engineer-in- charge (Item of joint fillers, sealants, dowel bars with sleeve/ tie bars to be paid separately).Cement concrete manufactured in automatic batching plant (RMC plant) i/c transportation to site in transit mixer |
| 85 | 61 Providing and laying in position bitumen hot sealing compound for expansion joints etc. 16.46.1 Using grade ‘A’ sealing compound. per cm |
| 86 | 62 Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making goodthe walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size580x440 mm with integral type foot rests |
| 87 | 63 Providing & fixing white vitreous china water less urinal of size 600 x 330 x 315 mm having antibacterial /germs free ceramic surface, fixed with cartridge having debris catcher and hygiene seal. |
| 88 | 64 Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.Flexible pipe32 mm dia |
| 89 | 65 Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 90 | 66 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge . concealed work including cutting chases and making good the walls etc.,20 mm nominal outer dia .Pipes. |
| 91 | 25 mm nominal outer dia .Pipes. |
| 92 | 67 Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.Circular tank |
| 93 | 68 Providing and fixing PTMT bib cock of approved quality and colour.15 mm nominal bore, 90 mm long, weighing not less than 93 gms |
| 94 | 69Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931.15 mm nominal bore |
| 95 | 70Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:893115mm nominal bore |
| 96 | 71 Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms. |
| 97 | 72 Providing & fixing chrome plated brass battery based infrared sensor operated pillar cock, having foam flow technology.15 mm nominal bore |
| 98 | 73 Providing and fixing square-mouth S.W. gully trap class SP1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design :150 x 100 mm size P type.With sewer bricks conforming to IS : 4885 |
| 99 | 74 Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 250 mm dia. R.C.C. pipe |
| 100 | 75 Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone- III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone- III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1ement : 3 coarse sand) finished with floating coat of neat cement and makingInside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : 19.7.1.1 With common burnt clayF.P.S. (non modular) bricks of class designation 7.5 |
| 101 | 76 Constructing brick masonry circular type manhole 0.91 m internal dia at bottom and 0.56m dia at top in cement mortar 1:4 (1 cement : 4 coarse sand), inside cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement, foundation concrete 1:3:6 mix (1 cement : 3coarse sand : 6 graded stone aggregate 40 mm nominal size), and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement, all complete as per standard design :0.91 m deep with S.F.R.C. cover and frameheavy duty, HD-20 grade designation) 560 mm internal diameterconforming to I.S. 12592, total weight of cover and frame to be notless than 182 kg., fixed in cement concrete 1:2:4 (1 cement : 2coarse sand: 4 graded stone aggregate 20 mm nominal size)including centering, shuttering all complete. (Excavation, foot rests and 12mm thick cement plaster at the external surface shall be paid for separately) :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 102 | 77 Constructing brick masonry road gully chamber 50x45x60 cm with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450 mm pre-cast R.C.C. horizontal grating with framecomplete as per standard design : bricks in cement mortar 1:4 (1 cement : 4 coarse sand ) with precast R.C.C. vertical grating complete as per standard design : 19.28.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 103 | 78 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS : 1285, fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC/neoprene felt etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing and paneling to be paid for separately) :Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 104 | 79 For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of PVC / neoprene gasket required (Fittings shall be paid for separately).Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 105 | 80 Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineer-in-Charge :With average thickness of 120 mm and minimum thickness at khurra as 65 mm. |
| 106 | 81Providing and fixing soil, waste and vent pipes :100 mm diaHubless centrifugally cast (spun) iron pipes epoxy coated inside & outside IS:15905 |
| 107 | 82 Providing and fixing plain bend of required degree.100 mm diaHubless centrifugally cast (spun) iron pipesepoxy coated inside & outside IS:15905 |
| 108 | 83 Providing and fixing double equal plain junction of required degree.100x100x100x100 mm Hubless centrifugally cast (spun) iron pipes epoxy coated inside & outside IS:15905 |
| 109 | 84 Providing and fixing single equal plain junction of required degree :100x100x100 mmHubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905 |
| 110 | 85 Providing and fixing double equal plain invert branch of required degree:100x100x100x100 mm Hubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905 |
| 111 | 86 Providing and fixing single equal plain invert branch of required degree :100x100x100 mm Hubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905 |
| 112 | 87 Providing and fixing single unequal plain invert branch of required degree :Hubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905 |
| 113 | 88 Providing and fixing Hubless centrifugally cast iron offsets epoxycoated inside & outside as per IS:15905130 mm offsets With 100 mm dia |
| 114 | 89 Providing and fixing to the inlet mouth of rain water pipe PTMT (an Engineering Thermoplastic) grating square (Slit) 150 mm square with a height of 8 mm and weighing not less than 100 gms. |
| 115 | 90 Providing and Fixing Delhi quartz stone cladding upto 10 meter height of approved quality of size 9\"x9\"x4\" or as approved by Engineer-in-charge in irregular pattern with around 10 mm thick Groovesincluding embedding every tenth layer and bottom most layer in masonry or concrete after making necessary chases of size min. 75x75 mm over 20 mm thick bed of cement mortar 1:3 (1 Cement : 3 coarse sand), with ruled pointing in (1 white cement : 2 stone dust) with an admixture of pigment to match the shade of stone in approved design. The work shall be done as per approved sample all complete as per the directions of Engineer-in-charge. |
| 116 | 91 Delhi quartz stone (approved quality of size 9\"x9\"x4\" or as approved by Engineer-in-charge) in flooring, risers of steps, skirting, dado and pillars laid on 20mm (average) thick cement mortar 1:3 (1 Cement : 3 coarse sand), with ruled pointing in (1 white cement : 2 stone dust) with an admixture of pigment to match the shade of stone in approved design etc. all complete as per the directions of Engineer-in-charge. |
| 117 | 92 P/F CPVC union approved make CPVC pipes i/c cutting and making all complete as per the directions of Engineer-in-charge.a) 25 mm nominal bore |
| 118 | b) 32 mm nominal bore |
| 119 | 93 P/F CPVC ball valve (gate valve) of approved make in CPVC pipes i/c cutting and making all complete as per the directions of Engineer-in-charge.a) 25 mm nominal bore |
| 120 | b) 32mm nominal bore |
| 121 | 94 Providing and fixing uplasticised PVC connection pipe with brass unions :a) 45 cm length and 15 mm nominal bore |
| 122 | 95 Providing and fixing 600mm CP towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour all complete as per directions of engineer-in-charge |
| 123 | 96 Providing and fixing PTMT grating of approved quality and colour. Circular Typea) 125 mm nominal dia with 25 mm waste hole/without hole |
| 124 | 97 Providing and fixing wash basin , 15 mm sensor (AC/DC) taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required all complete as per the directions of Engineer-in-charge.a) white vitreous china Oval shape wash basin of size 545 x 400x 185 mm with a single 15 MM CP brass sensor (AC) taps. |
| 125 | 98 Extra forlapatto finishGranite in lieu of polished granitein item No. 41 all completed as per the directions of Engineer-in-charge. |
| 126 | 99 Providing and layingHDPE 500 Micron Geomembrane Pond Lining sheet on earth surfaces with minimum 300 mm overlaps on all sides , keeping the sheets pressed in positiontill earth laying above is not complete. It should be ensured that no punctures are caused and the laid surface is completely impermeable. All completed as per the directions of Engineer-in-charge. |
| 127 | 100 Providing and laying HDPE Geocells 3D cellular confinement system ,thickness 1.2 mm height per cell75 mm , width per cell 712 mm with water flow porosity.Manufactured from permeable geotextile fabric and supplied at site in flat packed panel form Geo Cell is to beexpanded on-site to form a honeycomb-like structure which can be filled withsoil . Item is inclusive ofsteel pins to secure the panelsto ground all completed as per the directions of Engineer-in-charge. |
| 128 | (ii) Electrical Works101 Wiring for light point/fanpoint/exhaust fan point/call bell pointwith 1.5Sq.MmFRLS PVC insulated copperconductor single core cablein surface / recessedmedium class PVCconduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 Sq.Mm FRLS PVC insulated copper conductor single core cable etc. as required: Group C |
| 129 | 102 Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.: Group C |
| 130 | 103 Wiring for twin control light pointwith 1.5 Sq.Mm FRLS PVC insulatedcopperconductor single core cable in surface/recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 Sq.Mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 131 | 104 Wiringforpowerplugwith 2 x 4 Sq.Mm. FRLS PVCinsulated, copperconductor single core cable insurface / recessed medium class PVCconduitalongwith 1 no 4 Sq.Mm FRLS PVC insulated copper conductor single core cable forloopearthing as required. |
| 132 | 105 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.a) 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 133 | b) 2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 134 | c) 4 X 4 sq. mm + 2 X 4 sq. mm earth wire |
| 135 | d) 4 X 10 sq. mm + 2 X 6 sq. mm earth wire |
| 136 | 106 Supplying and fixing two module5 step type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 137 | 107 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings). |
| 138 | 108 Supply and fixing of suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps. modular switch, connection etc. as required. |
| 139 | 109 Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \"C\" curve including connections, painting etc. as required. |
| 140 | 110 Supplying of following sizes one number XLPE insulated and PVC sheathed / XLPE aluminium armoured power cable of 1.1 KV gradeUG Cable etc complete as requireda) 4 x 25Sqmm |
| 141 | b) 3.5X300 sqmm |
| 142 | c) 4X6 Sq mm |
| 143 | 111 Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.a) Upto 35 sq. mm (clamped with 1mm thick saddle) |
| 144 | b) Above 185 sq. mm and upto 400 sq. mm (clamped with40x3mm MS flat clamp) |
| 145 | 112 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.a) Upto 35 sq. mm |
| 146 | 113 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. a) Above 185 sq. mm and upto 400 sq. mm |
| 147 | 114 Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. |
| 148 | 115 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as requireda) 4 X 25 sq. mm (28mm) |
| 149 | b) 3½ X 300 sq. mm (70mm) |
| 150 | c) 4 X 10 sq. mm (25mm) |
| 151 | 116 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)8 way (4 + 24), Double door |
| 152 | 117 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)a) 8 way double door |
| 153 | b) 12 way double door |
| 154 | 118 Supplying and fixing 5 amps. to 32 amps. rating, 240 volts `C\" series,miniature circuit breaker (MCB)suitable for inductive load offollowingpolesin the existingMCBDBcomplete with connections, testing andcommissioning etc. as required: single pole |
| 155 | 119 Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 30 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required:63 Amps |
| 156 | 120 Providingand fixing hexagonal fan boxcircular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing. |
| 157 | 121 SITC of 1200mm (Nominal Size)LED luminaire ofminimum 40 wattmade of extruded aluminium housing suitable for 220 Volt AC colour temp. 6500K and efficacy better than 100 lumens/watt, with integral electronic driver, general colour rendering index (CRI) Ra > 80. Service life L70 (tq 25 °C) = 50,000 h. IK02/0,2 J, P.F>0.95, THD<10%, Protection IP20 etc complete as reqd. |
| 158 | 122 SITC of10 watt mirror light fixture made of extruded aluminium housing suitable for 220 Volt AC colour temp. 6500K and efficacy better than 100 lumens/watt, with integral electronic driver, general colour rendering index (CRI) Ra > 80. Service life L70 (tq 25 °C) = 50,000 h. IK02/0,2 J, P.F>0.95, THD<10%, Protection IP20 etc complete as reqd. |
| 159 | 123 SITC of minimum 12WLED surface Downlighterand a minimum system efficacy of 100 lm/W. The luminaire shall have a rated system lifetime of 50,000 burning hours at L70 with LG7 Complaint, new backlit design. The luminaire should have a color temperature between 6500K and CRI>80. The luminaire shall meet IP20 rating with THD<10% and PF > 0.95. The luminaire housing should made of aluminium and the luminaire optics shall have a high efficiency diffuser with more than 85% transmittance etc complete as reqd. |
| 160 | 124 Supplying, Installation, Testing and Commissioning ofsurface mounting IP-65, water proof minimum 10 Watt LED bulk head light fitting with polycarbonate diffuser, single phase, 100-270V AC, effiicacy 100 Lumens/ watt complete with integral electronic driver etc complete as reqd. |
| 161 | 125 SITC of LED flood light fixture suitable for minimum 70 Watt for area lighting. Optical system of high-quality UV and temperature-resistant optical lens systems with rotationally symmetrical light distribution. Floodlight housing of die-cast aluminum, powder coated, highly weather resistant. minimum luminous efficiency of luminaire 100 lm/W. correlated colour temperature (CCT) 6500 K, general colour rendering index (CRI) Ra > 70. Service life L70(tq 25 °C) = 50,000 h. IK05/0,2 J, P.F>0.95, THD<10%, Protection IP65 etc complete as reqd. |
| 162 | 126 Providing and fixing ofLED bollard luminaire of 10 Watt of height minimum 582mm as required, correlated colour temperature (CCT) 6500 K, operating voltage 120-277V. Impact resistance IK10 with LDPE protector. Service life L70(tq 25 °C) = 50,000 h.surge protection upto 10KV, Protection IP66 etc complete as reqd. |
| 163 | 127 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. |
| 164 | 128 Supplying, Installation, Testing and Commissioning of following sizes Heavy duty Exhaust Fan with Aluminium Louvers including connection with 3 core PVC insulated PVC sheathed flexible copper conductor cable on the existing window opening / Structure / Box complete etc. as required :300 mm sweep 900 rpm. The exhaust fan shall be fixed on minimum 10 mm thick bakelite sheet having suitable opening for exhaust fan. |
| 165 | 129 SITC of 1.5 Tr capacity air conditioner, 5 star rated Inverter type having only cooling facility suitable for operation of 215±10% volt, 50 HZ, A.C supplywith ecofriendly gas havingcordless remote control, fittings&required one copper conductorcabletoconnectunitto socket out with 3 pin 25 amp plug top.Installationandcommissionofunitto becompleteinallrespectwithsatisfactionof engineer-in- charge. Completed with upto 3 mtr refrigerant pipe and copper conductor cable of suitable size duly insulated withnitrile rubber tubular insulation between each set of indoor & outdoor units including making hole in the wall with the help of core cutter including repairing etc as per specification.(Note: The outdoor unit & indoor unit shall have copper coil for condenser and evaporater) |
| 166 | 130 Supplying, Installation and welding the copper pipe with the existing pipe of 1.5 TR refrigerant copper pipe work with fitting duly insulated with 19/13 mm thick closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specification all piping insidethe room shall be properly supported with M. S. hanger / angles / clamping arrangement, dash fasteners suitably run on existing cable tray etc. as required. |
| 167 | 131 SITC of 1.5TR AC Outdoor unit powder coated standrequired as per site condition wall / Floor Mounted. |
| 168 | 132 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 3 x 2.5 sq. mm For AC split |
| 169 | 133 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on walla) 25 mm nominal outer dia Pipes |
| 170 | 134 Providing services for operation of various pumpset for water supply, fountain etc in one shift (six days a week).The job includes the cleaning of pumpset, fountain, panels etc and to upkeep all the Electrical and Mechanical equipment in healthy working conditions. The timing can be changed as per the requirement on site or direction of engineer in charge.) a) For One Year |
| 171 | 135 Providing and fixing of self illuminated / auto glow \"EXIT/Directional \" signs printed on photoluminescentsheet containing self illuminated base chemical, of appropriate size not less than 250 x 150 mm(nominal), suspended from ceiling or fixed to the walls with accessories as perdirection of engineer in charge. |
| 172 | 136 Earthing with copper earth plate 600mmx600mmx3 mm thick including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 mtr long etc. with charcoal, coke and salt etc. complete as reqd. |
| 173 | 137 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 174 | 138 Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/terminating with nut, bolt, spring, washer etc. as required.(Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) |
| 175 | 139 Providing and fixing 25mmx5mm Copper strip in 40 mm dia GI pipe from earth electrode including connections with brass nut bolt spring washer excavation and refilling etc. complete as required. |
| 176 | 140 Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/terminating with G.I. nut, bolt, spring, washer etc. as required.(Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) |
| 177 | 141 Providing and fixing 25mmx5mm GI strip in 40 mm dia GI pipe from earth electrode including connection with G.I nut bolt spring washer excavation and refilling etc. complete as required |
| 178 | 142 Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required. |
| 179 | 143 Fixing of lightning conductor finial (single prong) with base plate including holes etc. complete as required |
| 180 | 144 Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run) |
| 181 | 145 Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run) |
| 182 | 146 Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required |
| 183 | 147 Providing and laying G.I. tape 32 mm X 6 mm from earth electrode directly in ground as required |
| 184 | 148 SITC of free standing floor mounted dust and vermin proof compartmentalised IP54cubical panels made out of CRCA sheet, required hardware, duly treated for derusting in 7 tank process with dephosphating and with powder coating on both side of panels in desired shadeThe panel having PU/ Neoprene rubber gasket of not less than 3mm thickness , separate detachable gland plate M.S. base channel, hinged door with locking arrangement for equipment /switchgear. Thickness of sheet shallnot be less than 2.0mm up to 600 mm length / widthof any compartment and be of 2.0 mm above 600 mm. Load bearing structure shall beof 2.0 mmthick sheet supported by base M.S. channel if required. Side walls and cable alley compartments having bolted type doors with / withoutdetachable extension type structure.Also TP&N aluminium busbar for 300 Amps of suitable rating for connections and other required Accessories. All complete as per CPWD specifications anddirection of Engineer-in-charge. (Panels shall be TTA approved) (Including voltmeter, ammeter, indication lamp, CT, selector switch)a) INCOMING :i) 200 A FPMCCB (25kA), with Thermal Magnetic Releases for O/C & S/C protection + E/F release b) BUS BAR :i) 300A, 25KA,FP Alu. Bus Bar with Heat shrunk, colour coded PVC Sleeved duly supported on SMC/FRP supports in sealed bus bar chamber.-1 No.c) METERING AND INDICATIONSi)R/ Y/ B phase LED indicating lamps with control MCBs - 2 No.ii) Digital ammeter(0 - 200A), Cl. - 1, CTR - 5Awith built in selector switch & CTs- 1 No.iii) Digital Voltmeter (0 - 500V), 415V, Cl. - 1 with built in Selector switches & control MCBs - 1 No.iv) \"ON / OFF / TRIP\" LED lndicating lamp with control MCBs for outgoing feeder- 1 No.d) OUT GOINGS :i) 63A TPN MCCB, 15kA, with Thermal Magnetic Releases for O/C & S/C protection + E/F release - 3 No.ii) 63A TPN MCB, 10kA, C-Curve- 10 No.iii) 40A DP MCB, 10kA, C-Curve- 4 No. |
| 185 | 149 Supplying, installation, testing & commissioning of 225 mm (9\") Borewell submersible pumpsets rated voltage of 415 volts three phase, 50 Hz frequency, AC supply, 30 KW or 40 HP 3 stage, outlet size 125 MM rated current 75.0 Ampere 60 m head at 114 cum per hour(1900 LPM) output, Insulation B class, Protection IP 68, Impeller of stainless steel, Bowl/stage casing in Cast Iron, Pump shaft in stainless steel, motor body in stainless steel, motor shaft in stainless steel, Finished rotor in Copper, NRV is Cast iron, Sution in Cast Iron, Pump / motor bushes - LTB, thrust bearings of Carbon +SS |
| 186 | 150 Supplying, installation, testing & commissioning of set of 2 nos. pressure sand filter with 2 nos. Raw water pumps. The raw water pumps shall have a flow of 114 cum per hour with a head of 25 meters of 15 HP, 3 phase, 415 Volts, 50 Hz. The sand filters each shall have flow of 114 cum per hour with MS material3600 mm diameter, 1800 mm height of shell, vessels made of MS as per IS -2062, Surface velocity 114 Cum / hr, operating pressure 3.0 kg /sq cm, design pressure 5.5 kg/ sq cm, butterfly valve , frontal piping in MS, piping size 150 mm, inlet distributor bell mouth type, using filter media quantity of 18900 kgs, internal painting in black epoxy, external painting in 2 coats of red oxide primer and 2 coats of synthetic enamel, Flange table as per BS table 10D |
| 187 | 151 Supplying, installing, testing & commissioning of monoblock WaterLifting Pump capable of priming upto 3 meters static suction lift without foot valve at rated head and discharge, capable to withstand voltage fluctuations from 180-240 Volts with Non overloading power characteristics, Single phase, Current 5.5 Amps, Power 1HP or .75 KW, Suctionx delivery size 25x25 mm, Output capacity 2700 to 630 LPH Suction depth upto 22 meters and Delivery head 36 meters , Impeller Cast Iron, Shaft Carbon steel, motor body extruded aluminium, Delivery casing Cast Iron, Cover NDE - Aluminium , weight approx. 20 Kg to feed Overhead Tank. (1HP) including all fittings as per direction of Engineer-in-charge. |
| 188 | 152 Supplying, installation, testing & commissioning ofSolar street lightwith integrated solar panel, LED light , Lithoum based battery and a PIR motion sensor. Light voltage - 12 W LED , Solar panel 40 watt Mono Perc, Battery 12.8 V, 18 Ah Lithoum ferro Phosphate battery , Charge controller type MPPT , Motion sensor range 12 Meters 18 Hrs. back up , adjustable mounting bracket with a warranty of 18 months, Dusk to Dawn operation with auto Dimming capability , Complete with installation , on pre - erected poles, testing and commissioning |
| 189 | 153 SITC of 4.5 m high 76 mm dia Solar octagonal poles including foundation .3 mx.3mx.6 m deep RCC 1:2:4 with foundation bolt and provided electrical connection as directed by Engineer in charge |
| 190 | 154 SITC of musical fountain consisting of following with approval of Engineer-in-charge for the design of fountain integrated with music by suitable demonstration and presentationsa Nozzles - Make Ripplesi Arching Jet (Vertical Jet (AF 50-15 ) 10M Height- 2 Nos.ii Sunburst Jets x 7nos. on 50NB GI Header 2m long -10M Height- 1 nos. iii Chasing Jets x 5nos. on 50NB GI Header 3m long -12M Height- 5 nos. b LED Lights IP68- Make Ripplesi S54C Submersible LED DMX512 Lights 54W (18x3W LED\"s With SS plate )- 6 Nos. ii S36C Submersible LED DMX512 Lights 36W (12x3W LED\"s)- 32 nos. iii SS Light Stand Single Way 25 NB- 32 nos. iv SS Light Stand 3 way 50 NB- 2 nos. v Junction Box for Lights with DMX Transmitter & DMX Lights card (for S36C/S54C Subm. DMX512 Lights)- 6 nos. vi Junction Box Stand Fortripod- 6 nos. c Sub. Pumps- Make Ripples i Pump 5.5 HP Submersible 3 Phase- 2 nos. ii Pump 3HP Submersible 3 Phase- 6 nos. d Control System- Make Sycronorm ( Germany)i Show Controller (Syncronorm V : Nano 1024 with required accessories)- 1 nos. ii Show Programming (Max 3 Min)- 2 nos. iii Main Distribution Panel- 1 no. e Control Panel for pump starters (Panel Equipments Make-L & T, Heger, Elmex, Rishabh, FTC, Esbee, Salzer, Schneider, Dowels, Jainsons, KSS, SG, Siemens etc.) with DMX receiver and Relay Cards.- 1 nos. f Digital control panel for lights & Solonoids with DMX receiver and relay cards - 1 no.g Valves & fittings etc of required size -MakeHM/Zoloto/ Ripplesi Valves, fittings etc of required size - Lotii Solonoid Valve 25mm SS/Brass (With IP68 Coil 24v DC , NC Type )- 25 nos. h Wires/cablesof various sizes including required accessories - Make Poly cab/ Power light/ Everest- Lot i Conduits, bends, fittings etc. of required size- Make AKG/ Setia - Lot |
| 191 | 155 SITC of Geyser fountain consisting of following with approval of Engineer-in-charge for the design of fountain by suitable demonstration and presentationsa Nozzles-MakeRipples i Geyser 25S(M.O.C Gunmetal - Noryl - SS) 24 Nos. b LED Lights IP68- Make Ripplesi S09W Submersible LED Light – Warm White 9W (3X3W LED’s)- 25 nos. ii SS Light Stand Single Way 25 NB- 23 nos. iii SS Light Stand 2 Way 25 NB- 1 nos. iv Deck Box - ABS- 1nos. v Power Supply 12V DC /20 Amp.- 1 nos. c Sub. Pumps- Make ripplesi Pump 5.5 HP Submersible 3 Phase- 2 nos. d Control Panel made of 16 gauge CRC/MS sheet fabricated with epoxy powder coated with Amp Meter, Volt Meter, MCB\"s, Push Buttons, Isolator, Indicators, Panel Incomer with MCB\"s, Neutral Link, Starter for pumps with Contactor, Over Load Relay & Space for power supply of lights (Panel should be Complete in all respect) - Make Ripplese Pipes, Valves, fittings etc of required sizei Pipes in uPVC 10kg pressure and fittings (Heavy) make Finolex/ Prince/ Supreme - Lotii Valves, fittings etc of required size- HM/Zoloto - Lotf Wires/cablesof various sizes including necessary accessories- Make Power lite/ Everest/ Polycab i Wires/Cables of various sizes including required accessoriesg Conduits, bends, fittings etc. of required size- Make AKG/setiai Conduits, Bends, Fittings etc of required sizeh Filteration system complete set with 650mm dia filter, Nozzles, pump, chlorine dosing unit, Suction/Vacuum Point including plumbing and Electrical Work (Flow 11m3/hr. Turnover 5.1hrs, Total Volume 56.1cum) Make Ripples- 1nos. |
| 192 | 156 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.a) 120 mm dia (OD-120 mm & ID-103 mm nominal) |
AI Tender Summary
Tender Timeline
Jun 23, 2022
11:30 IST
Tender Published
Tender notice published.
CompletedJul 08, 2022
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedJul 08, 2022
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender