}

Setting Up Of A New Govt. Integrated School At Jaigaon In Kalinchi Block Of Alipurduar District - External Electrical Works.-2 S & F 10Mm Thick Hylam Sheet Best Quality On Wall Of Required Size For Installation Of Service Meter & Cut Out Incl. S&F 3 Nos. , alipurduar-West Bengal

Public Works Department-PWD has published Setting Up Of A New Govt. Integrated School At Jaigaon In Kalinchi Block Of Alipurduar District - External Electrical Works.-2 S & F 10Mm Thick Hylam Sheet Best Quality On Wall Of Required Size For Installation Of Service Meter & Cut Out Incl. S&F 3 Nos. . Submission Date for this Tender is 12-07-2022. Uniform Tenders in alipurduar West Bengal. Bidders can get complete Tender details and download the document.




Tender Notice

32799274
Setting Up Of A New Govt. Integrated School At Jaigaon In Kalinchi Block Of Alipurduar District - External Electrical Works.-2 S & F 10Mm Thick Hylam Sheet Best Quality On Wall Of Required Size For Installation Of Service Meter & Cut Out Incl. S&F 3 Nos.
Open Tender
Indian
West Bengal
alipurduar
12-07-2022

Tender Details

Setting Up Of A New Govt. Integrated School At Jaigaon In Kalinchi Block Of Alipurduar District - External Electrical Works.-2 S & F 10Mm Thick Hylam Sheet Best Quality On Wall Of Required Size For Installation Of Service Meter & Cut Out Incl. S&F 3 Nos. 500V, 250A Fuse Base And Bridge ( Make- Bpc ) & Neutral Bar By Nut Bolt After Drilling Hole As Per Direction Of E.I.C. 3 Sitc Oflt, Cubicle Type, Floor Mounted , Totally Enclosed, Fully Compartmentalizedelectrical Control Panelsuitable For Operation At 415 Volt, 50 Hz, As Per Size, Design & Drawing To Be Approved By Eic.The Panel Board Will Be Fabricated By Cpri Approved Panel Maker As Per Detail Specification Below. 4 The General Construction Of The Panel Will Conform To Is 8623:93 As Amended Up To Date. The Degree Of Ip Protection For The Enclosure Will Be Ip-42.It Will Have Multi Tier Arrangement, Having Necessary Cable Alley At Both End, With Rigid And Self Supporting Structure Fabricated With Sufficient No. Of Channels & Covered By 2Mm Thick Crca Sheet With Base Structure By 75X40x4mm Channel. 5 All Incoming, Outgoing Sfus / Mccbsare To Be Housed In Respective Compartments With Hinged And Gasketed Doors At The Front. All The Doors Should Have Panel Lock Arrangements In Such A Fashion That It Cannot Be Unlocked Unless The Respective Feeder Remains Off. The Rear Of The Panel Should Have Gasketed Wire Net Guard For Ventilation And Arrangement Shall Be Made For Easy Access To Each Compartment By Providing Rear Doors With Locking System. 6 The Panel Is To Be Properly Gasketed To Prevent The Dust And Vermin. All Vertical And Horizontal Bus Bar Chambers Are To Be Properly Arranged And All Electrical Switches, Bus Bars Are To Be Fixed By Ms Nut-Bolts On Suitable Hylam Board / Non - Hygroscopic Insulators Of Adequate Size And Dimensions. The Outgoing Feeder Connections From Respective Switches Are To Be Made At The Rear Side Of The Panel By Means Of Bus-Bar / Multi Core Copper Cables, To Be Terminated On Bolted Type Terminals For Cable Connections Or Bush Insulators For Bus Connection. 7 It Will Be Powder Coated After Seven Tier Pre Treatment Process. 2 Nos. Copper Strip Of Size As Per Is Shall Be Fixed All Around The Panel And Will Be Connected To 2 Nos. Copper Earth Bus Bar Connected To Incoming Earth Conductor. All Tests Should Be Made For The Complete Panel. The Following 415 / 230Volt Open Execution Type Switches With Fuses& Accessories Will Be Fixed In The Panel. 8 Incoming 9 A.415 V, 250 A Tpn Sfu ( Open Execution Type ) With 3 Nos Hrc Fuses. -1 No. ( Make:L&T / Abb / Siemens ) 10 ( I ) 415 V, 250A, 4 Poletpn C / O-1 Set ( Make:L&T ) 11 Busbar 12 A.415 V, 415 A Capacity 4 Nos Tinned Copper Bar ( As Per G.S ) -1 Set 13 Outgoing 14 A.415 V, 125 A Tpn Sfu ( Open Execution Type ) With 3 Nos Hrc Fuses. -4 No. ( Make:L&T / Abb / Siemens ) 15 B.415 V, 63 A Tpn Sfu ( Open Execution Type ) With 3 Nos Hrc Fuses. -4 No. ( Make:L&T / Abb / Siemens ) 16 B.415 V, 32 A Tpn Sfu ( Open Execution Type ) With 3 Nos Hrc Fuses. 2 Nos. ( Make:L&T / Abb / Siemens ) 17 Accessories 18 ( I ) Load Manager Class 1.0 Accuracy Load Manager 3 Ph 4 W 240V 5A With Rs 485 Port ( For Measurement Of V, A, F, Kw, Kwh ) With 3 Nos. 500 / 5Amps Bar Primary Type Cts 15 Va Burden Class 1.0 Accuracy, And 3 Nos. 2 Amps Back Uphrc Fuse Or Spmcbs 10 Ka Breaking Capacity - 1 Set. 19 ( Ii ) 3 Nos. Phase Indication Lamps Led Type In Ryb Colours With Toggle Switches And 3 Nos. Of 2 Amps Back Up Hrc Fuse Or Spmcbs 10 Ka Breaking Capacity - 1 Set. 20 Additional Provision For Incorporation Of 415 V, 415 A 4 Bar Tinned Copper Bus Bar Of 0.5 Mtr Long ( Approx ) As To Gs In The Existing Above Panel Including Fabrication Charges For Panel & Making Necessary Connections As Per Direction Of E.I.C Including S&F Of 1 No 415 V, 250 A Tpn Sfu ( Open Execution Type ) With 3 Nos Hrc Fuses. ( Make:L&T / Abb / Siemens ) ( Note: Design & Drawing Should Be Approved By Eic Before Installation. ) 21 Supplying And Drawing 1.1 Kv Single Core Stranded Fr Pvc Insulated & Unsheathed Single Core Stranded Copper Wire ( Brand – Finolex / Havels / Polycab / Kei / Rr ) Of The Following Sizes Through The Rigid Conduit Pipe Making Necessary Connection As Required Incl. S / F Rigid Pipe As Per Reqd. Incl. S / F 25 Mm Rigid Pipe. 22 ( I ) 4X16+ 2X10 Sq. Mm. Pvc Copper Wire. 23 Supply And Fixingdouble Door Spndb ( 2+6 Way ) As Per Gs With Ip 42 / 43 Protection Concealed In Wall After Cutting Wall As Per Direction Of Eic With Dp Isolator 40A, 6 Nos. 6A Sp Mcb. ( Make: Legrand / L&T / Abb / Siemens / Schneider ) 24 Distribution Wiring In 1.1 Kv Grade 3X22 / 0.3 ( 1.5 Sq Mm. ) Single Core Stranded Fr Pvc Insulated & Unsheathed Copper Wire Partly In 20Mm Size Pvc Rigid Conduit Fr ( Precision Make ) [ For Horizontal Run &Above False Ceiling Portion Only ] And In 19 Mm Bore.3Mm Thick Polythene Pipe [ For Vertical Run Embedded In Wall ] , To Light / Fan / Call Bell Points With Modular Type Switch As Per Gs With Following Average Run, [ As Per Approved List Of Material ] [ Average Run 8 Mtr. ] 25 Dist. Wiring In 3 X 22 / 0.3 ( 1.5 Sp.Mm ) Single Core Stranded Fr Pvc Insulated & Unsheathed Single Core Strandedcopper Wire In 19 Mm Bore, 3Mm Thick Polythene Pipe Complete With All Accessories Embedded In Wall To 240 V 6A 5 Pin Plug Point With Modular Type Plug Socket & Switch As Per Gs. [ As Per Approved List Of Material ] [ On Board ] 26 S&F 250 Volt 2X6 Amp 5Pin Modular Type Plug Socket ( Brand- Schneider / Legrand - Arteor / Myrius ) With 2X6 Amp Modular Type Switch, Without Plug Top On 6 Module G.I. Modular Type Switch Board With Top Cover Plate Complete Flushed In Wall Incl. S&F Switch Board And Cover Plate And Making Necessary Connections With Pvc Copper Wire And Earth Continuity Wire Etc As Per G.S. 27 Supply & Fixing 240V, 16A 3Pin Modular Type Plug Socket ( Brand-Schneider / Legrand-Arteor / Myrius ) With16 A Modular Type Switch, Without Plug Top On 4 Module Gi Modular Type Switch Board With Top Cover Plate Flushed In Wall Incl. S&F Switch Board And Cover Plate And Making Necessary Connections With Pvc Cu Wire And Earth Continuity Wire Etc As Per G.S. 28 Sub Head-Fittings 29 Supply & Delivery Single Led Fittings ( Philips Make, Cat No.Tmc 501 P 1Xt-Led 22W P3241 Incl.1X Mas Led ( Pc Body ) Tube 1200Mm 20W865 T8 Ind I – 2100Lm. Or Equivalent Product Of Bajaj / Wipro Having Similar Specification In All Respect 30 Supply & Delivery Double Led Fittings ( Philips Make, Cat No.Tmc 501 P 2Xt-Led 22W P3242incl.2X Mas Led ( Pc Body ) Tube 1200Mm 20W865 T8 Ind I – 2100Lm Or Equivalent Product Of Bajaj / Wipro Having Similar Specification In All Respect 31 Fixing Only Single / Twin Florescent Light Fitting Complete With All Accessories Directly On Wall / Ceiling With Hw Block And Suitable Size Ms Fastener, Nut-Bolt, Ceiling Plate, Nipples Etc. As Required 32 Fixing Only Single / Twin Fluorescent Light Fitting Suspended 25 Cm Bellow The Ceiling With 2 No. 20 Mm Dia Ei Conduit ( 14 Swg ) Supports Fixed With “L” Type Ms Clamp Whose One Side Fixed On Ceiling With Sutable Size 4 Nos. Fastener And Other Side Connected With The Conduit With Suitable Size Of Bolts And Nuts Incl. S&F Ei Conduit, “L” Type ( 125Mmx125mm ) 6Mm Thick And 25Mm With Ms Clamps And Connecting The Length Of Pvc Insulated Wire And Mending Good Damages To Original Finish And Painting Etc. By 2X24 / 0.20 Mm ( 1.5Sqmm. ) Flexible Copper Wire Of 1.10 Mt. Length. 33 S / F 240V Decorative Surface Mounted Led Down Light ( Philips Make - Cirrus Mini Pro Sm200c Led16s 6500 Psu Od Wh / Bajaj / Wipro / Ge ) Suitable For Ceiling Incl. Making Necessary Connection. 34 Supply & Delivery 250 Volt 56 ( 1400 Mm ) Sweep A.C. Ceiling Fan Complete With All Accessories ( Without Regulator ) ( Orient / Usha Striker / Havells Pacer / Crompton ) Colour Approved By E.I.C ) 35 Supply & Delivery 250 Volt 48 ( 1200 Mm ) Sweep A.C. Ceiling Fan Complete With All Accessories ( Without Regulator ) ( Orient / Usha Striker / Havells Pacer / Crompton ) Colour Approved By E.I.C ) 36 Fixing Only Ceiling Fan Complete With Blades, Canopy, Fork, Rubber Bush Etc. Incl. S&F Connecting Wire For Down Rod Upto 30 Cm Incl. Painting The Rod With Approved Paint And Making Necessary Connection As Required By 2X1.5 Sqmm Flexible Copper Wire. 37 S&F 230V, 50Hz, 12 Sweep Exhaust Fan 1420 Rpm Mounted On Wall Including S & F Of Louver Shutter ( Make: Epc ) 38 S&F 230V, 10Watt Led Lamp ( Make – Phlips / Wipro / Bajaj / Ge ) . 39 S&F 240V, Ac / Dc Superior Type Ding Dong Call Bell ( Anchor ) On Hw Board Incl. S&F Of Hw Board. 40 S & Installation Of 18 Sweep Floor Mounted Industrial Type Air Circulator Pedestal Fan ( Make- Orient / Epc / Crompton ) 41 S&F 230V, 450Mm Sweep Wall Mounting Type Metal Bracket Fanon Wall By Clamping Arrangement ( Make - Orient / Epc / Crompton ) 42 S&F 415V, Tpn On Load Changeover With Sheet Steel Enclosure On Angle Iron Frame On Wall With Nuts & Bolts:250A ( Make: L&T / Siemens / Abb ) 43 S&F 415V, Tpn Sfu With Sheet Steel Enclosure On Flat / Angle Iron Frame On Wall With Nuts Bolts Etc Incl. S&F 3Nos Din Type Hrc Fuses As Per Rating:250 A ( Make: L&T / Siemens / Abb ) 44 Supplying Of One Number 1.1 Kv Gradexlpe Insulated Andpvc Sheathed Aluminium Conductor Cable ( Armoured ) Conforming To Is: 7098 / 1988 With Its Latest Amendment Of Following Size. [ Make: Nicco / Gloster / Havells / Polycab / Kei / Rr ] 4Core 120Sqmm 45 Laying One No Cable Above 35Sqmm And Up To 185Sqmm In Underground Trench 460Mm Wide X 760Mm Avg. Depth With Brick Protection On The Top Of The Cable As Per Gs And Also Filling The Soil Levelling Up Etc. 46 S&F Compression Gland With Brass Gland, Ring & Rubber Ring For 4Core 120Sqmm Cable And Finishing The Ends Of The Cable With Solder Less Socket ( Dowels Make ) With Necessary Tapes, Paste And Jointing Materials As Per G.S. 47 Earthing With 50 Mm Dia Gi Pipe 3.64 Mm Thick X 3.04 Mts. Long And 1 X 4 Swg Gi ( Hot Dip ) Wire ( 4 Mts. Long ) , 13 Mm Dia X 80 Mm Long Gi Bolts, Double Nuts, Double Washers Incl. S & F 15 Mm Dia Gi Pipe Protection ( 1 Mts. Long ) To Be Filled With Bitumen Partly Under The Ground Level And Partly Above Ground Level Driven To An Average Depth Of 3.65 Mts. Below The Ground Level As Below:By Tata-Medium Gi Pipe 48 Sub Head- Feeder Piller ( For Street Light & Ground Light ) 49 Feeder Piller Box:Supply And Installation Of Outdoor Feeder Piller Box Of ( 4Ft X 3Ft X 1.2Ft ) . The Body And Upper Portion Of The Piller Box Made Of 4Mm Thick Ms Sheet And Bottom Portion With 10Mm Thick Ms Plate Rigidly Fixed By Nuts, Bolts, Washers Etc. 50 Additional Provision For Pad Locking Is Also To Be Provided And 2Nos Mechanical Lock Both Top And Bottom Portion. Provision Of Ventilation Grill Should Be Triangular Shape Made Of Ms Plate Duly Welded To Lateral Side, The Central Ventilation Spot At Starting Surface Of The Top Of The Piller Box. Provision For 2Numbers Earthing Terminal By 25 X 6 Mm Gi Flat Having Suitable Nuts Bolts Washers For Connecting The Accessories With Necessary Interconnection Between Incoming & Outgoingswitches By Suitable Size Cu Flat / Wire / Rod Duly Sleeved & Insulated Through Collar. 51 The Inside Of Pillar Box Will Be Painted By 1 Coat Of Redled / Zinc Chromate And The Outside Will Be Painted By 2 Coats Of Synthetic Anamel Paint Over 1 Coat Of Redled / Zinc Chromate And Ms Plate At Bottom Portion With Two Coats Of Black Japan Paint After Finishing The Paint Properly The Internal Ei Works Of Piller Box Should Be Suitable To Withstand 2Kv For One Minute.All Fabrication Work Should Be Done As Per Drawing And Direction Of Eic. The Piller Box Comprising With The Following-A ) S&F 250V Required Size Db With Ip-54 Protection With 1No 32A 4Pole Mcb ( C Curve, 10Ka ) , 1No 24Hrs Programmable Digital Timer Switch With 32 A 4P Contactor Incl Change Over Isolator - 1Setb ) S&F 415V, Mcb Isolator 32 A Fp ( Legrand / Schneider / Abb ) - 1No 52 Busbar:415V, 100A, 4Bar Tinned Copper Bus Bar As Per G.S. 53 Installation Of The Above Piller Box With Brick Foundation Of Size 1500 X 1000 X 750Mm With Hard Jhama Cement Mortar Shoaling At Bottom 300Mm Below Gl & 450Mm Above Gl Neatly Plastered & Neat Cemented Finish As Per Direction Of The Eic. 54 Sub-Head- Cable Tray 55 Supply & Fixing Of Perforated Gi Cable Tray With Performation Not More Than 17.5 % Suspended From Ceiling Incl. S & F Gi Connector, 6 Mm Dia Ms Suspender, Bolts & Nuts, Steel Fastener Etc. As Required Of The Following Size Incl. Al Painting Of Ms Support. 56 With 300 X 50 X 1.25 Mm ( 18 Swg ) 57 Supply & Fixing Of Perforated Gi Cable Tray Bend With Performation Not More Than 17.5 % Suspended From Ceiling With 2 Nos Suspenders & 25 X 25 X 3 Mm Angle Iron For Supporting The Cross Member Incl. S & F Gi Connector, 6 Mm Dia Ms Suspender, Bolts & Nuts, Steel Fastener Etc. As Required Of The Following Size Incl. Al Painting Of Ms Support.300 X 50 X 1.25 Mm ( 18 Swg ) 58 Supply & Fixing Of Perforated Gi Cable Tray Tee With Performation Not More Than 17.5 % Suspended From Ceiling With 2 Nos Suspenders & 25 X 25 X 3 Mm Angle Iron For Supporting The Cross Member Incl. S & F Gi Connector, 6 Mm Dia Ms Suspender, Bolts & Nuts, Steel Fastener Etc. As Required Of The Following Size Incl. Al Painting Of Ms Support.300 X 50 X 1.25 Mm ( 18 Swg ) 59 Sub-Head- Lightning Conductor 60 S&F Lightning Conductor Air-Terminals Made Of 15Mm Dia 1500 Mm Long Gi Pipe ( Isi-Medium ) Having Five Prongs Of 4 Swg Gi ( Hot Dip ) Wire At Top With 85Mm Dia 6Mm Thick Gi Base Plate At Bottom Incl. Necessary Holes Etc Duly Grouted On The Parapet Etc In Cc Morter ( 4:2:1 ) . 61 Supply & Fixing Gi ( Hot Dip ) Strips 20 Mm X 3 Mm Thick For Horizontal Run On The Parapet / Roof / Wall With Gi Saddles 1100 Mm Apart Incl. Mending Good The Damages To Building Works. 62 Supply & Fixing Of Gi ( Hot Dip ) Strips 20 Mm X 3 Mm Thick For Vertical Run On Wall With Gi Saddles Spaced Not Exceeding 1000 Mm Apart Incl. Mending Good Damages To Building Works. 63 Making Soldered Joints Between Conductor / Conductor & Air Terminals By 7 / 10 Stranded Gi ( Hot Dip ) Wire Incl. Supply Of Jointing Materials & Painting With 2 ( Two ) Coats Of Bituminous Paint 64 Making Soldered Joints Between Conductor / Down Pipes / Other Metallic Objects By 7 / 10 Stranded Gi ( Hot Dip ) Wire Incl. Supply Of Jointing Materials & Painting With 2 ( Two ) Coats Of Bituminous Paint 65 Hiring Charges For Scaffolding Arrangements Including Dismantling At The End Of Work And Carriage For Lc Installation, Per Storied Of Building Per Vertical Run. 66 Supply & Fixing Of Testing Joints By 20Mm X 3Mm Thick Gi ( Hot Dip ) Strips 125Mm Long Grouted On Wall Having Clearance Of 6Mm From Wall For Making Necessary Connections With Thimbles At The End Of 7 / 10 Swg Gi ( Hot Dip ) Stranded Wire And 4Swg Gi ( Hot Dip ) Wire Of Vertical Conductor And Conductor From Earth Electrode Completewith S&F Thimbles, Gi Bolts, Nuts, Check-Nuts, Spring Washers Etc As Required. 67 Sub-Head-Earthing 68 Excavation Of Soil For Installation Of Earth Electrode For Soft Soil. 69 Earthing With 50 Mm Dia Gi Pipe 3.64 Mm Thick X 3.04 Mts. Long And 1 X 4 Swg Gi ( Hot Dip ) Wire ( 4 Mts. Long ) , 13 Mm Dia X 80 Mm Long Gi Bolts, Double Nuts, Double Washers Incl. S & F 15 Mm Dia Gi Pipe Protection ( 1 Mts. Long ) To Be Filled With Bitumen Partly Under The Ground Level And Partly Above Ground Level Driven To An Average Depth Of 3.65 Mts. Below The Ground Level As Below:By Isi-Medium Gi Pipe 70 Extra For Providing Masonery Enclosure On The Top Of The Earth Electrode Of Overall Size 86.36Cm X 86.36Cm X 46Cm Deep ( Below Ground Level ) Complete With Cemented Brick Work ( 1:6 ) Of 25Cm Width Duly Plastered With Cement Morter ( Inside ) Ci Hinged Inspection Cover Of Size 36.56Cm X 35.56Cm With Locking Arrangement. Gi Reducer Including Drilling Of 46Nos 12Mm Dia Holes On The Gi Pipe. 71 Extra For Treatment Of Soil By Using Salt & Charcoal Or Coke For Plate / Pipe Electrode. 72 Providing And Laying Gi Tape / Strip 40Mm X 6Mm From Earth Electrode Directly In Ground As Required. 73 Sub-Head-Street Light 74 Supply & Delivery Ofhotdip Galvanised ( As Per Is:2629 / Is 2633 / Is 4759 And With Its Latest Amendment ) Octagonal Pole Made Ofht Steel ( Sheet Thickness -3Mm ) Conforming Tograde S355 Of Bsen 10025 Along With Welded Base Plate Of Required Sizeconforming To Is: 226 / 2062With Integrated Control Box With Required Sizes Studs For Termination Of 2 Core 10 / 4 Core 16 Sq Mmal ( Armoured ) Cable Including S&F1 No6 Amp Sp Mcb ( C-Series ) For Each Out Going Circuit To The Fittings With Proper Pad Locking Arrangement For The Followingpole-- 7 Mtr Long [ Top Dia ( A / F ) - 70 Mm, Bottom Dia ( A / F ) -130 Mm ] Base Plate Size : 200 Mm X 200Mm X 12 Mm.. ( Make :Bajaj / Philips / Valmont / Cg / Transrail / Bansal ) . 75 Erection Of The Following Octagonal Pole Bydesigning And Castingrcc ( M 20 ) Foundation Ofsuitable Size As Specified Belowconsidering The Safe Soil Bearing Capacity At Site As T / Sq M, Includingexcavation Of Earth, Providing, Cutting, Bending And Placing In Position Reinforcement As Per Drawing And Providing Pipe For Cable Entry And Exit As Required And Providing And Fixing Of 4 Nos.Foundation Bolts ( J Type ) As Specified Belowand As Per Drawing On Ground Surface Including Back Filling And Cleaning Extra Earth -7 Mtr Long [ Foundation Size - 500 Mm X 500 Mm X 1200 Mm, J Bolt Size - M 20 X 600 ] 76 Sitcof Single Dip Galvanized Steeloverhang Bracket ( Swan Neck Type ) At The Top Of The Polehaving 1 Mlengthcomplete With All Fixing Arrangements As Required Including Painting ( A ) Single Arm. 77 Supply & Fabricated And Fixing Angle Iron Bracket Chair For Fittings Of Flood Light For Ground. 78 Sitcofroad Lighting Luminaries ( Ip 65 ) With Peanut Lens Andhigh Power Led Andto Ensure Uniform Distribution, Higher Spacing Between Poles And Maintenance Free System And System Lumen Output Will Be Minimum 7000 Lumensuitable For Use With 230Volt 50Hz Ac Supply Etc As Required. ( Make - Philips Model No. Brp062 Led 80 Ww Slc A1 S1 Psu ) .Or Equivalent Of Wipro / Bajaj / Ge ) 79 Sitcofroad Lighting Luminaries ( Ip 65 ) With Peanut Lens Andhigh Power Led Andto Ensure Uniform Distribution, Higher Spacing Between Poles And Maintenance Free System And System Lumen Output Will Be Minimum 7000 Lumensuitable For Use With 230Volt 50Hz Ac Supply Etc As Required. ( Make - Philips- Bvp192 Led 82 Ww Ho Nb Fg Gr Psu / Cg Or Equivalent Of Wipro / Bajaj / Ge ) 80 Sitcofpost Top Gate Lighting Luminaire ( Ip 65 ) And Resistant To Impact And Corrosion, Glare-Free And Better Uniformity With Peanut Lens Andhigh Power Led [ Make - Crompton Greaves, Model - Lpto-40 Ww / M / Or Equavalent Product Of Philips / Wipro Having Similar Specification ] 81 Supplying Of One Number 1.1 Kv Gradexlpe Insulated Andpvc Sheathed Aluminium Conductor Cable ( Armoured ) Conforming To Is: 7098 / 1988 With Its Latest Amendment Of Following Size. [ Make: Nicco / Gloster / Havells / Polycab / Kei / Rr ] ( A ) 4C16sq.Mm 82 Supplying Of One Number 1.1 Kv Gradexlpe Insulated Andpvc Sheathed Aluminium Conductor Cable ( Armoured ) Conforming To Is: 7098 / 1988 With Its Latest Amendment Of Following Size. [ Make: Nicco / Gloster / Havells / Polycab / Kei / Rr ] ( A ) 3C10sq.Mm 83 Laying Of One No. Cable Up To 35 Sq.Mm In Underground Trench 460Mm Wide X 760Mm Average Depth, With Brick Protection On The Top Of The Cable With 8 ( Eight ) Nos. Bricks Per Metre, Including Filling The Space Between The Bricks And Cable And Also The Trench With Shifted Soil, Levelling Up And Restoring Surface Duly Rammed. 84 Laying Of One No. Cable Up To 25 Sq.Mm Through Saddling Arrangement As Per Gs. 85 Supplying And Fixing Compression Type Gland Complete With Brass Gland, Brass Ring & Rubber Ring For Dust & Moisture-Proof Entry Of Xlpe / Pvc Armoured Cables As Below : 86 4 Core16 Sq. Mm 87 3 Core10 Sq. Mm 88 Finishing The End Of Following Xlpe / Pvc Armoured Cables By Crimping Method Incl. Supplying And Fixing Solderless Socket ( Dowels Make ) , Tapes, Anticorrosive Paste & Jointing Materials : 89 4 Core16 Sq. Mm 90 3 Core10 Sq. Mm 91 S & L Of 1.1 Kv Grade 3 X 1.5 Sq Mm Fr Single Core Multi Stranded Copper Wire For Connection From Loop Box To Fittings Through 13 Mm Dia Polythene Pipe. 92 Finishing Of The Pvc Insulated Wire ( 3 X 1.5Sqmm ) Ends By Socketing With Pin / Ring Type Copper Sockets And Insulated Tapes Etc., Including Supplying Sockets, Tapes. 93 S & F Of Medium Gauge G.I Pipe ( Isi Medium ) Having The Following Diameter [ 32 Mm Diameter ] For Protection Of Cable With Necessary Fitting And Jointing Materials As Required. 94 Supply And Fixing Of Ceiling Mounted Led [ Make: Philips - Sm200c Led16s 6500 Psu Od W H / Similar Product Of Wipro / Bajaj / Ge ] 95 Earthing With 50 Mm Dia Gi Pipe 3.64 Mm Thick X 3.04 Mts. Long And 1 X 4 Swg Gi ( Hot Dip ) Wire ( 4 Mts. Long ) , 13 Mm Dia X 80 Mm Long Gi Bolts, Double Nuts, Double Washers Incl. S & F 15 Mm Dia Gi Pipe Protection ( 1 Mts. Long ) To Be Filled With Bitumen Partly Under The Ground Level And Partly Above Ground Level Driven To An Average Depth Of 3.65 Mts. Below The Ground Level & Restoring Surface Duly Rammed As Below ( Isi Medium G.I Pipe ) 96 Sub-Head-Roof Top Light 97 S& Erection Of Mini Pole Of Size 2 Mtr. Long Approx 50 Mm.Dia Gl Pipe Class - B , On The Front Pump House S& Providingm.S. Plate Incl. Necessary Arrangement Near Base Plate For Smooth Cable Entry Position And Making C.Cmuffing Of Size 450 X 450 X 600 Mm. Height With Cement Mortar Mixture ( 6 ; 3 ; 1 ) Incl. Neat Cement Finish Before Cheeping Properly The Existing Roof Incl. S& Providing Earth Bolt After Drilling Hole Etc. Incl. Painting With 2 Coats Of Synthetic Enamel Paint Over Coats Ofr. O. Primer As Per Direction Of E. L. C. 98 S / F Jacket Single Arm Header Assembly Having 100Mm Dia Top Cap Of 0.30 Mtr Long Duly Welded With 1.5 Mtr Long 40 Mm Dia Pipe Arm Bracket Detachable Type At An Angle 110 Degree With The Pole Incl. Painting With 2 Coats Of Synthetic Enamel Paint Over A Cost Of R.O. Primer As To Gs 99 Supplying And Fixing Gi Water Proof Looping Cable Box Having Hinged Gi Top Cover Having 4 Mm Thick With Rubber Gasket Lining, Railway Type Mechanical Locking Arrangement, Earthing Terminal With Lug Etc. Of The Following Sizes As Indicated Below, Comprising Of One 250 V, 15 A Kit-Kat Fuse Unit, One Nl On Porcelain Insulator Etc. And Housing The Same In Pole Muffing Incl. Addition And Alteration To The Existing Cc Muffing ( 6:3:1 ) After Dismantling The Damaged Looping Cable Box Etc. Where Necy. Incl. Painting. 250 X 250 X 100 Mm 100 S & L Of 1.1 Kv Grade 3 X 1.5 Sq Mm Fr Single Core Multi Stranded Copper Wire For Connection From Loop Box To Fittings Through 13 Mm Dia Polythene Pipe. 101 S & F 230V, 110W Led Streetlight Fittings ( Make Philips / Osram / Jagure, Catno-Brp409 Led110 Cw M2 Fg Psu Gr V3 ) On Top Header As Per Direction Of Elc. 102 Sub-Head-Led Signage 103 Designing, Fabrication, Supply, Installation, Testing & Commissioning Of Outdoor Led Signage ( Approx Size 16 Length X 6 Height ) In English ( Letters Given & Approved By Concerned Dept ) For Letters With Following Specification. 104 ( A ) The Box For The Signage Will Be Fabricated Inaluminium Square Tube Of Size 25Mm X 25Mm Of 16 Gauge Complete With Necessary Priming And Painting. The Front Of The Box Will Be Covered With 3Mm Thick Aluminium Composite Panel ( Acp ) Sheets Of The Entire Board. The Board To Be Fixed In Front Of The Canopy By Providing Required Support & Angle Bracing. The Complete Installation Will Be Water, Vermin And Dust Insulated And Protected. 105 ( B ) Letter Description: Approx 9X5 Size Of Letters Made Of Acrylic Sheet With Male Female Attachment, On Router Cut Acp Sheet Of Front Incl. All Accessories As Required. 106 ( C ) Led Illumination: High Bright, High Wave Length Closed Type Waterproof White Led Modules ( 0.72W Or Higher ) Mounted On Interior Side Of Female Part Of Letter With Power Wire Running Back To A Central Power Area With 12Volt Led Power Transformer To Adequately Drive The Whole Led Modules Without Flicker. 107 ( E ) Internal Electrical Wiring Will Be Done By Halogen Free Flame Retardant Hrfr Compound Insulated ( Unsheathed ) 1.5Sqmm Copper Flexible Cable Through Interior Conduit And Electrical Raceway. 108 Supply & Installation Of Above Led Signboard On The Gate / Roof / Wall As The Case May Be Including Making Necessary Arrangement For Fixing The Board As Per Direction Of Eic. Construction Of Sufficient No Of Brick Pillar With Stay Rod Of Angle Iron For Supporting The Board Will Also Cover In The Scope Of Work. 109 Supply & Installation Of Desktop Computer Of Following Specification - Hp Desktop I3 11G / 512 Ssd / 8Gb Ram Windows 10Monitor 18.5Ledkey Board, Mouseincluding Supply & Installation Of 600Va Apc Make Ups & 1 No. Antivirus Single User For 3 Years ( Quick Heal Total Security )

Key Value

Document Fees
Refer document
EMD
INR 117619.0 /-
Tender Value
INR 58.80 Lakhs /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail