Repair / Maintenance Of Fire Fighting, Dg Set And Other Connected Items At Af Station Palam Under Ge ( Af ) Palam Delhi Cantt- 10

Tender Notice

32789302
Repair / Maintenance Of Fire Fighting, Dg Set And Other Connected Items At Af Station Palam Under Ge ( Af ) Palam Delhi Cantt- 10
Indian
Delhi
22-06-2022
14-07-2022
15-07-2022

Tender Documents

Additional Details Available on Click
✓ Tendering Authority
✓ Publication Document
(Tender Document / Tender Notice )

Tender Details

Repair / Maintenance Of Fire Fighting, Dg Set And Other Connected Items At Af Station Palam Under Ge ( Af ) Palam Delhi Cantt- 10

Key Value

Document Fees
INR 500 /-
EMD
INR 29920.0 /-
Tender Value
INR 14.96 Lakhs /-

Attachment

FileName File Description File Size
b7d0bd0f-4609-4287-a110-7e71627d9189.html Tender Notice 49.5 KB
34TENDER.pdf Tender Document 872.0 KB
BOQ_595299.xls Tender Document 480.0 KB
Tendernotice_1.pdf Tender Document 276.0 KB

BOQ Items

Name of Work: REPAIR/ MAINTENANCE OF FIRE FIGHTING, DG SET AND OTHER CONNECTED ITEMS AT AF STATION PALAM UNDER GE (AF) PALAM DELHI CANTT- 10
Sl. No. Item Description
1Supply and fixing fire hydrant landing valve type "A" (single head outlet) gun metal of 80mm dia landing valve with 63mm dia female outlet complete and 80mm inlet with rubber blank cap and chain as per IS 5290-1983, suitable for brigade hose of 63mm with coupling conforming to IS 903 including taking down the existing one all as specified and directed by Engr-in-charge.
2Supply and fixing of weather proof standard fire hose box made of 18SWG MS sheet 800mmX600mmX250mm with double door with 4mm thick glass and door frame made of 16 gauge including locking arrangement by allen key stove enamelled fire red finish with "fire hose" marked on front and brilliant white inside yard, suitable for housing of and consisting of 2 length RRL, hose pipe conforming to IS 6361979 (type-II) of 63mm dia GM instantaneous male and female (IS:903) and branch pipe ( nozzle) 12.5mm dia (for external hydrant) including taking down the existing one all as specified and directed by Engr-in-charge.
3Supply, fixing, testing and commissioning of wall mounting swinging type first aid fire hose reel with drum, hanging bracket 30mtr long and 20mm dia high pressure hose reel as per IS 444 with gun metal shutt off nozzle. The hose reel shall be conforming to IS 884-1985 (for internal hydrant and one each an either side of stage) including taking down the existing one complete all as specified and directed by Engr -in-charge. (Note : (i) Rate shall be included for 25mm dia MS pipe connection from riser to hose reel sockets, nipples, elbows and ball valve (25mm dia).(ii) Drum shall be fixed on adjoining wall through anchor fastener/cement concrete hook or MS stand as per site requirement and the rate for fixing/hanging items deemed to be quoted in the item rate.
4Supply and fixing in replacement of fire hydrant Mild Steel stand post 1.5mtr height single head outlet gun metal of 80/150mm dia all as specified and directed by Engr-in-charge.
5Supply, fixing , testing and commissioning of GM four way, fire brigade inlet to hydrant ring with 63mm dia instantaneous type inlet and 150mm dia flanged outlet conforming to IS 904 with blank cap and chain including taking down the existing one all as specified and directed by Engr-in-charge.
6Supply, fixing , testing and commissioning of GM two way, fire brigade inlet to hydrant ring with 63mm dia instantaneous type inlet and 150mm dia flanged outlet conforming to IS 904 with blank cap and chain including taking down the existing one all as specified and directed by Engr-in-charge.
7M & L in replacement of pressure switch universal type for maintaing pressure in fire fighting line all as specified and directed by Engr-in-charge.
8M & Lin replacement of pressure gauge4 " dial 0-21 Kg rating for monitoring pressure in fire fighting line all as specified and directed by Engr-in-charge.
9Supply ,fixing ,testing and commissioning in replacement of 150mm bore MS pipe heavy duty Class "C" ISI marked (IS:1239) with all necessary fittings & fabrication like tees, elbow, flanges, reducer, gaskets, nut and bolts etc welding or screwed joint as required including fixing of pipe with necessary standard clamps structural steel support (chilly make) as required at site including painting with two coats of synthetic enamel paint of post office red color over one coat of red oxide primer all as specified and directed by Engr-in-charge.
10All as per item No.9 above but 80mm bore pipe.
11Supply & fixing in replacement of butterfly valve of size 150 mm dia conforming to IS 13095, flanged ends drilled type with steel spindle including nuts, bolts, washers and jointing material all as specified and directed by Engr-in-charge.
12Supply & fixing in replacement of butterfly valve of size 100 mm dia conforming to IS 13095 , flanged ends drilled type with steel spindle including nuts, bolts, washers and jointing material all as specified and directed by Engr-in-charge.
13M&L for construction of brick masonary valve chamber of size 900mmx900mmx900mm (internal dimensions) with 150mm thick PCC 1:4:8 type D-2 in foundation,brick masonary built in CM 1:6, 50mm thick PCC 1:3:6 type C-1 using 20mm graded stone aggregate in coping, cement plastering 15mm thick in CM 1:6 including provision of 3mm thick MS plain sheet cover with locking arrangement embedded with angle iron frame of size 40x40x6mm and painted with two coats of synthetic enamel paint over a coat of red oxide primer including dismantling of existing chamber all as specified and as directed.
14M & L for boring holes under road pavement/ hard standing by trenchless technology using ultra sound technique and necessary machine for accomodating pipe of size 150/80 mm dia suitable for 0.4 Mpa working pressure.
15Material and labour for cutting of hard standing/road upto 0.6 meter depth and 0.60 mtr width suitable for fixingof 150/80mm boreMS pipe and filling with ready mix cement concrete 1:2:4 type B-2 and making good disturbed surface.
16S & F in repair Fire foam concentrator drum of 200 ltr capacity for producing mechanical foam for fire fighting in and including replacement of existing plastic/PVC pipe, nozzle/fixing mechanism all as specified and directed by Engineer-in-Charge.
17S&F in replacement of 63mm dia and 15mtr long controlled perclating rubberised fabric hose conforming to IS: 8423 (type A) including gun metal male and female instantaneous coupling bound and rivetted to hose pipe with 1.5mm dia copper wire complete in all respect, hose BS marked, conforming to IS : 636 type II and complete male female coupling conforming to IS :903all as specified and directed by Engr-in-charge.
18M&L for servicing of induction motor 75 HP coupled with fire pump complete including oiling, burnt winding replacement, greasing replacement of wornout rubber packing, wornout nuts and washers etc including testing to the entire satisfaction of Engineer-in- Charge.
19M&L for servicing of induction motor 15 HP coupled with fire pump complete including oiling, burnt winding replacement, greasing replacement of wornout rubber packing wornout nuts and washers etc including testing to the entire satisfaction of Engineer-in-charge.
20M&L for Maintenance and servicing of standby DG Set including draining out of diesel from tank , cleaningthe tank thoroughlyand refilling the drained out diesel, draining out engine oil from the sump, cleaningthe sump thoroughly and refilling the sump with new engine oil to it’s required level, replacing the fuel filter, lubricating oil filter , check & clean air cleaner, change air cleaner elements, Check coolant level & make up the same ,Drain the Fuel filter & water separator ,filling the starting batteries with electrolyte/Distilled water to maintain the required specific gravity, replace the u/s brass Connectors for batteries , cleaning of Battery terminals & applying petroleum jelly to battery terminal posts & brass connectors, changing of V-belts, changing hoses and clips of air cleaner,checking of exhaust leakage, governor, breathers etc, adjust/set the same for proper functioning of DG Set, checking offuel, oil and water/ coolantlevel etc, adjusting and keeping the fan belts to the desired tension, tightening all the bolts and nuts to the required torque etc, cleaning the DG Set with accessories asprescribed by the manufacturer and test for satisfactory running of DG set for two hour at connected load & record shall be made in respect of RPM , oil pressure, oil temp , Coolant temp. Voltage, frequency , load current ,Battery charging , fuel consumption etc as directed by the Engr- in-charge for 125 KVA DG Set (Make : Kirloskar installed at Technical pump house , Pinto park pump house and RV Area Pump house. Note :-1. Engine oil for refilling will be measured and paid Separately. 2.Coolant for make up will be measured & paid separately. 3. DHPP will be issued free supply by dept for testing only.
21All as per item No. 20 here in beforebut for70 KVA DG Setinstalled at Old and new domestic pump house Camp area.
22All as per item No. 20 here in beforebut for 75 KW diesel driven CF pump engine installed at CPRU fire fightng pump house.
23All as per item No. 20 here in beforebut for 50 KVA DG Setinstalled at CPRU pump house,Map pump house and new Pinto Park.
24All as per item No. 20 here in beforebut for 40 KVA Make : Cuminsat STP Pinto Park and new STP.
25All as per item No. 20 here in beforebut for 35KVA installed at MT astha pump house and Map pump house Camp Area.
26All as per item No. 20 here in beforebut for 15 KVA DG Set installed at 1AFSR, CWE borewell and Maude line borewell.
27All as per item No. 20 here in beforebut for 200 KVA DG Set Make : Kirloskar installed at CPRU and UGBO .
28Supply and filling lubricating oil for DG Sets as per manufacturer"s recommendation.Make - IOC, Castrol, Hindustan Petroleum.
29Supply and filling coolant for Radiator as per manufacturer"s recommendation.
30M&L for overhauling of radiator assembly by removing from engine, transporting to the workshop and removing the sediments and scales, corrosion etc by means of acid cleaning and high pressure water washing and air cleaning, gas welding / soldering with good quality materiaL for stopping the leakage etc, re-assembling the same with new gaskets and transporting to the site, fixing to the engine with new hoses, clips complete as required for DG Set 125 KVA.
31All as per item No. 30 here in before 75 KW diesel driven CF pump engine installed at CPRU fire fightng pump house
32All as per item No. 30 here in beforebut for70 KVA
33All as per item No. 30 here in beforebut for50 KVA
34All as per item No. 30 here in beforebut for40 KVA
35All as per item No. 30 here in beforebut for35 KVA
36All as per item No. 30 here in beforebut for DG Set 15 KVA
37All as per item No. 30 here in beforebut for DG Set 200 KVA
38Supply & fixing in replacement of RPM Meter on DG Set complete.
39Supply & fixing in replacement of Battery lead 1.25mtr long made of 25 Sqmm single core copper conductor (Positive & Negative)including fixing of both end brass terminal (ring type & screw type).
40M&Lfor servicing of self starter assembly of DG Set up to 200 kVA capacity 24 volts by disconnecing the self starter from the engine and transport to workshop for carryout overhauling by replacing all unserviceable spare parts including pinion, carbon brushes , bushes, contacts, copper plates, jumping leads ets and replacing the filled coil and varnishing all as directed.
41Supply & fixing in replacement of inter connected Battery lead to connect two Nos batteries of capacity 12Volt 150/180AH made of 25 Sqmm single core copper conductorincluding fixing of both end brass terminal (screw type).
42Draining out existing radiator, water cleaning thoroughly the radiator fins by air blower recharging the chemically treated coolant including replacement of all water hose pipe suitable for 15 kVA to 200 kVA DG Sets.
43Supply and fixing in replacement of radiator belt "V " suitable for 125 KVA DG set all as specified and directed by Engr-in-charge.
44All as per item No.43 above but" V "Belt suitable for 70 KVA DG set
45All as per item No.43 above but " V "Belt suitable for 50 KVA DG set
46All as per item No.43 above but " V "Belt suitable for 40 KVA DG set
47All as per item No.43 above but " V "Belt suitable for 35 KVA DG set
48All as per item No.43 above but " V "Belt suitable for 15 KVA DG set
49All as per item No.43 above but " V "Belt suitable for 200 KVA DG set
50M&L for preparation of old painted surface of fuel tank by scrapping / removing old paint , dirt etc, and applying two coats of blue synthetic enamel paint over a coatprimer by spray machine including calibration of capacity of tank and marking the level of capacityall as specified and directed by Engineer-in-charge suitable for : a) Fuel tank in respect of 125KVA DG set capacityk -03 Nos. b) Fuel tank in respect of 70KVA DG set capacityk -02 Nos. c) Fuel tank in respect of 50KVA DG set capacityk -01No. d) Fuel tank in respect of 40KVA DG set capacityk -02 Nos. e) Fuel tank in respect of 35KVA DG set capacityk -02 Nos. f) Fuel tank in respect of 15KVA DG set capacityk -03 Nos. g) Fuel tank in respect of 200KVA DG set capacityk -02 Nos.
51Dismantling existing fuel injection pump of DG set , transporting to work shop and overhauling complete including calibratingand re-fixing the same and testing the DG Set to the entire satisfaction of Engineer-in-charge for 200 KVA capacity DG Sets installed at CPRU and UGBO.
52All as per item No.51 above but Tech pump ,Pinto park pump house and RV Area Pump house-125 KVA capacity.
53All as per item No.51 above but Old domestic pump house-70 KVA capacity.
54All as per item No.51 above but New domestic pump house-70 KVA capacity.
55All as per item No.51 above butMap pump house and old pinto park -50 KVAcapacity.
56All as per item No.51 above butCPRU pump house -50 KVA capacity.
57All as per item No.51 above but STP Pinto Park and new STP -40 KVA capacity.
58All as per item No.51 above butMT astha pump house -35 KVA capacity.
59All as per item No.51 above butMap pump house Camp Area -35 KVA capacity.
60All as per item No.51 above but 1 AFSR BOREWELL -15 KVA capacity.
61All as per item No.51 above but Maude line borewell and CWE office borewell- 15 KVA capacity.
62Dismantling rubber coupling of DG set and supply and fixing rubber coupling forfollowing DG sets including testing and commissioning complete : a)CPRU and UGBO -200 KVA b) Tech pump ,Pinto park pump house RV Pump house-125 KVA c) Old domestic pump house-70 KVA d) New domestic pump house-70 KVA e)Map pump house and old pinto park -50 KVA f)CPRU pump house -50 KVA g) STP pinto parkand new STP -40 KVA h)MT astha pump house -35 KVA i)Map pump house camp areae -35 KVA j) 1 AFSR BOREWELL -15 KVA k) Maude line borewell and cwe bore well- 15 KVA
63S&F in replacement of water temperature gauge of DG set including testing complete.
64S&F in replacement of Oil Pressure gauge of DG set including testing complete.
65Supply and fixing in replacement of self starter of capacity 24 volts DC suitable for 70 KVA capacity DG Set at New domestic pump house
66All as per item No.65 above but 200 KVA capacity DG set at UGBO.
67Disconnecting existing defective voltage stabilizer at different locationof 3 X 15 KVA capacity 3 phase 415 volts from electric mains Isolating the naked connections , removing from foundations by unscrewing the nuts bolts etc carrying to the factory /workshop for repair by draining out the transformer oil through the drain plug , dismantling both nut and bolt and lifting the top portion to carry out through inspection and clean the bottom portion of the voltage stabiliser tank by removing the mud and slurry and deposited material for prevention of short circuit and re-fixing in Original position after repair and testing complete all as specified and as directed by Engineer-in-charge.(Note : replacement of defective parts shall be measured and paid separately).
68Disconnecting existing defective voltage stabilizer at different location of 50 KVA capacity 3 phase 415 volts from electric mains Isolating the naked connections , removing from foundations by unscrewing the nuts bolts etc carrying to the factory /workshop for repair by draining out the transformer oil through the drain plug , dismantling both nut and bolt and lifting the top portion to carry out through inspection and clean the bottom portion of the voltage stabiliser tank by removing the mud and slurry and deposited material for prevention of short circuit and Refixing in Original position after repair and testing complete all as specified and as directed by Engineer -in - charge .(Note : replacement of defective parts shall be measured and paid separately).
69S&F in replacement of Electronic circuit card (PCB) suitable for Existing Make - Volina.
70S&F in replacement of PCB Holder suitable for Existing Make - Volina.
71S&F in replacement of rotary switch 5 Amps for RYB Phase .
72S&F in replacement of Micro processor based control card for Each phase ( Set of Three ) suitable for Existing Make - Volina
73S&F in replacement of Dimmer state unit 10 Amps suitable for existing Make - Volina.
74S&F in replacement of Dimmer state unit 60 Amps suitable for existing Make - Volina
75S&F in replacement of Digital Amp Meter with CTs suitable for existing Make - Volina
76S&F in replacement of voltmeter 0-500 Volts digital typesuitable for existing Make - Volina,ABB
77S&F in replacement of Panel lamp as per Existing ( set of three ).
78Supply & fixing in replacement ofMain transformersuitable for Servo Voltage stabilizer of capacity 15 KVA complete. Make-Vintek Electronics/volina.
79Supply & fixing in replacement ofMain transformer suitable for Servo Voltage stabilizer of capacity 50 KVA complete. Make-Vintek Electronics/volina.
80S&F in replacement of MCCB 3 pole 415 volts 125 Amps of breaking capacity 35 KA
81Supply and filling transformer oil at adequte temperature (without moisture) for top up as required suitable for voltage stabilizer all as specified and directed . Make : Power oil or its equivalent.
82Supply & fixing in replacement of lead acid battery 12Volts 90 AH of existing type & size suitable for Gen set 15 to 125 KVA inculding initial charging complete all as specified and as directed.
83M&L for preparation of old painted surface of Servo Voltage stabiliser by scrapping / removing old paint , dirt etc, and spray painting with two coats of blue synthetic enamel paint over a coat of primer including writing of MES / SM No of capacity 15 KVA all as specified and directed by Engineer-in-charge .
84Supply, installation and testing in replacement of maintenance free grounding(earthing) system complete burried directly in ground vertically (earth pit not less than ten feet below ground level) by making bore hole of 100 mm dia for inserting 01 No 17 mm dia molecular copper bonded high tensile low carbon steel circular earth electrode of 3 meter length with average copper thickness of 200 microns alongwith environmental friendly grounding enhancing compound and heavy duty (HDPE) PVC pipe cap all in below ground level and connected to copper strip 25 x 3 mm flat by means of brass metal bolts , nuts and washers etc including protection pipe of GI 40 mm bore med grade upto 7.5 meter length and connection of earth lead to maintain distribution/LT panel board/DG set with copper lugs complete all as specified and directed by Engineer in charge. Note : The rate for necessary earth work ,PVC pipe,copper strip and all required materials is deemed to be included in quoted rate of item.
85Supply and fixing in repair XLPE insulatedPVC sheathed heavy duty armoured cable with aluminium conductor 1100Volt of 70 Sqmm x 3.5 core size conforming to IS -7098 (Part-I).
86All as per item No.85 above but 95 Sqmm X3.5 core cable
87All as per item No.85 above but 120 Sqmm X 3.5 core cable
88M&L for cutting of Hardstanding/road by mannual method upto 0.45 mtr width and 15 cm deep for inserting GI pipe 50 mm diafor cable protection complete including ready mix concreate 1:2:4 and making good distrubed surfaceall as specified and as directed by Engr-in-Charge. (Note : Rate of GI pipe is demed to be included in the quoted rate).
89Excavation in trenches in soft/loose soil not exceeding 1.5 mtr depth and not exc 1.5 mtr wide for laying of pipes/cables etc and getting out.
90Returning, filling in including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick in soft/loose soil.
91Removing excavated soil not exceeding 50mtr and depositing where directed at a level not exceeding 1.5mtr above the starting pointall as specified and as directed by the Engineer-In-Charge
92M&L for sand cushioning (dry sand) to underground cable for cable protectionlaid in trenches / in existingcable ducts complete all as specified and as directed by the Engineer-In-Charge
93M&L for brick, subclass "B" well burnt, laid dry flat in trenches for protection of cable complete all as specified and as directed by the Engineer-In-Charge
94Supply & fixing in replacement of cable jointing kit andtesting complete for 1.1 kv grade cable for Indoor termination heat shrink type joint with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 120 Sqmm to 150 Sqmm. Make 3M/Denson/Raychem
95Supply & fixing in replacement of cable jointing kit andtesting complete for 1.1 kv grade cable for Indoor termination heat shrink type joint with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 70 to 95 Sqmm all as specified and directed. Make 3M/Denson/Raychem
96Supply and fixing in replacement of on load change over switch TPN 4 pole 200 Amp 440 volts conforming to relevant IS including all connecting and jointing material all as specified and directed. Make:- Havells/Standard/Legrand.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2022 · All Rights Reserved. Terms of Usage | Privacy Policy