| 1 | Earthwork in excavation of foundation trenches in ordinary soil(vide classification of soil item -A) anddisposal of the same to a distance upto 50M including all lifts levelling ramming the foundation trenches removing roots of trees, shrubs all complete as per approved design, building specification & direction of E/I. including extra for hard soil. |
| 2 | Providing course clean local Sand in filling in foundation trenches including ramming watering royalty complete job as per specification and direction of engineer in charge.\"back filling foundation and plinth |
| 3 | Providing PCC M150 in nominal mix of (1:2:4) in foundation with approved quality of stone chips 20mm to 6mm size graded and clean coarse sand of FM 2 to 3 including screening, mixing cement concrete in mixer and placing in position, vibrating striking , curing ,taxes and roylity all complete as per building specification and direction of E/I |
| 4 | Providing RCC M200 with nominal mix of (1:1.5:3) infoundation and plinth with approved quality of stone chips 20mm to 6mm size graded and clean coarse sand of FM 2 to 3 including screening, mixing cement concrete in mixer and placing in position, vibrating striking , curing (but excluding the cost of reinforcement) ,taxes and roylity all complete as per building specification and direction of E/I |
| 5 | Providing RCC M200 with nominal mix of (1:1.5:3) in beam with approved quality of stone chips 20mm to 6mm size graded and clean coarse sand of FM 2 to 3 including screening, mixing cement concrete in mixer and placing in position, vibrating striking , curing (but excluding the cost of reinforcement) ,taxes and roylity all complete as per building specification and direction of E/I |
| 6 | \"Providing 50mm Damp Proof Coarse with M20 (1:1.5:3) with approved quality of stone chips 20mm to 6mm size graded and clean coarse sand of FM 2 to 3 including screening,mixing cement concrete in mixer and placing in position, vibrating striking , curing (but excluding the cost of reinforcement) ,taxes and roylity all complete as per building specification and direction of E/I |
| 7 | Extra for water proofing Material |
| 8 | Providing designation 75A brick work)in CM 1:6 in superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10 mm thick mortar joints, costs of screening, materials, scaffolding, racking out joints to 15 mm depth curing, taxes and royalty all complete as per building specification & direction of E/I. |
| 9 | Providing RCC M200 with nominal mix of (1:1.5:3) in roof slab with approved quality of stone chips 20mm to 6mm size graded and clean coarse sand of FM 2 to 3 including screening, shuttering mixing cement concrete in mixer and placing in position, vibrating striking , curing (but excluding the cost of reinforcement) ,taxes and roylity all complete as per building specification and direction of E/I |
| 10 | Centering and shuttering including strutting , propping etc. and removal of form for Foundatoins ,footings,bases of columns ,etc for mass concrete. |
| 11 | Centering and shuttering including strutting , propping etc. and removal of form for Suspended floors,roofs,landings ,balconies and access platform,with water proof ply 12 thick . |
| 12 | Centering and shuttering including strutting , propping etc. and removal of form for Lintels, beams ,plinth beams , girders , bressumers and cantilevers. With water proof ply 12 mm thick. |
| 13 | Providing tor steel reinforcement of 10 mmdia. As per approved design and drawing excluding carriage of MS rods to work site cutting, bending, and binding with annealed wire with cost of wire removal of rust, placing the rods in position all complete as per building specification & direction of E/I. BCD SOR item no (i) 8 mm dia |
| 14 | (ii) 10mm dia |
| 15 | (iii) 10 to 20mm dia |
| 16 | Providing 12 mm cement plaster ( 1:6 ) with clean coarse sand of F.M.1.5 including screening ,curing with all leads & lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I. |
| 17 | Providing 12 mm thk. cement plaster ( 1: 3 ) on outside wallwith clean coarse sand of F.M.1.5 including screening ,curing with all leads & lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I. |
| 18 | Providing 6 mm cement plaster inceiling ( 1:4 ) with clean coarse sand of F.M.1.5 including screening ,curing with all leads & lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I. |
| 19 | Finishing with Deluxe Multi surface paint system for interiors and exteriors usingPrimer as per manufacturers specifications :13.48.1 Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including onecoat of Special primer applied @ 0.75 ltr /10 sqm. |
| 20 | Finishing walls with Acrylic Smooth exterior paint of required shade New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including primingcoat of exterior primer applied @ 2.20 kg/10 sqm) |
| 21 | Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS :15622 (thickness to be specified by the anufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. |
| 22 | Chequered terrazo tiles 22 mm thick with graded marble chips of size up to 6mm in floors, jointed with neat cement slurry mixed with pigment to match theshade of the tiles, including rubbing and polishing complete, on 20 mm thickbed of cement mortar 1:4 (1 cement :4 coarse sand) 1 Light shade pigment using white cement. |
| 23 | Providing and fixing aluminium work for doors, windows, ventilators andpartitions with extruded built up stanDSRd tubular sections/ appropriate Zsections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessaryfilling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free,straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid forseparately) : For fixed portion, Anodised aluminium (anodised transparent or dyed to required shade according |
| 24 | Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, inpanelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge. 21.2.1 Pre-laminated particle board with decorative lamination on one side and balancing lamination on other side |
| 25 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm) |
| 26 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, uffing, polishing and making curvature wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainlesssteel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc |
| 27 | Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete.Replacing pop with Berger wall putty. EXCLUDING COST of Plaster of paris. |
| 28 | Providing and applying fibre reinforced elastomeric liquid water proofing membrane with resilient acrylic polymers having Sun Reflectivity Index (SRI) of 105 on top of concrete roof in three coats @10.76 litre/ 10 sqm. One coat of self-priming of elastomeric waterproofing liquid (dilution with water in the ratio of 3:1) and two coats of undiluted elastomeric waterproofing liquid (dry film thickness of complete application/system not less than 500 microns). The operation shall be carried out after scrapping and properly cleaning the surface to remove loose particles with wire brushes, complete in all respect as per the direction of Engineer-in-Charge. |
| 29 | Supply, Installation, Testing and Commissioning of ongrid Solar PhotovoltaicPower PlantconformingtoMNREspecificationsasamended,consistingofMono/Poly Crystalline silicon solar cells, net metering facility, necessary protections, earthing, mounted on Aluminium/GI structure ofsuitable strengthwith following components complete as required:-a) Solar Photovoltaic Module of capacity 330 Wp or above, manufactured in India, conforming to IS 14286/ IEC 61215, IS/IEC 61730-Part-1, IS/IEC 61730-Part-2. Solar Photovoltaic Module conversionefficiency shall not be less than 16.5%. PV modules used in solar power plants/ systems must bewarranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. b) Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 400 V AC,threephase,4 wire, 50Hz +/- 2.5 Hz,output voltagesuitable togenerateAC Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 degree C. The PCU shall adjust the voltage and frequency level to suit the Grid Voltage Frequency.c) Data Monitoring System complete with accessories.d) Fixing of Arrayjunctionbox&MainjunctionboxwithIP65protectionand termination arrangement for incoming and outgoing cable along with glands, lugs and other accessories etc. as required.e) Lightning and surge voltage protection.f)Connections&Interconnectionsbysupplying&fixingrequired size XLPE insulatedcopper conductor 1.1 kV gradearmouredpowerandcontrolcables betweensolarmodules,mainpowercabletogridsupplyPCUunitalongwith supplying & fixing of necessary channel/conduit lugs andother accessories etc. asrequired. |
| 30 | DSR(E&M)(ITEMFOR SOLAR PHOTOVOLATIC POWER PLANT)IT. NO. 1 |
| 31 | Sub total Civil Work |
| 32 | Point wiring in PVC conduit, with pino type switch:-wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor singal core cable in surface/ recessed PVC conduit with piano type switch, phenolic laminated sheet, suitable size PVC/G.I box ect. asGroup A |
| 33 | S/F light plug point with piano type ccessories:-Supplying & fixing suitable size G.I / PVC box on surface or in recess with phenolic liminated sheet cover in front including providing & fixing 5 pin, 5/6 amps socket outlet & 5/6 amps piano type switch connection, painting etc, as requed. |
| 34 | S/F power plug point with piano type ccessories:-Supplying & fixing suitable size G.I / PVC box on surface or in recess with phenolic liminated sheet cover in front including providing & fixing 6 pin, 15/16 amps socket outlet & 15/16 amps piano type switch connection, painting etc, as requed. |
| 35 | Power plug wining in PVC conduit (2x4 sq. mm winning or loght/ power plug with 2x4 sq. mm FR PVC instaled copper/ conductor single core cable in surface/ recessed PVC condult along with 1 number 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing. as required |
| 36 | Circuit / Sub Main wining in PVC Conduit:Wiring for circuit/ sub-main wiring along with earth wire with the following size of PVC insukated, copper conductor, single core cable in surface/ recessed PVC conduit as required.2x1.5 sq.mm + 1x1.5 sq.mm earth wire |
| 37 | 2x2.5 sq.mm + 1x2.5 sq.mm earth wire |
| 38 | 4x6 sq.mm + 2x 6 sq.mm earth LDBs |
| 39 | 2x10 sq.mm + 1x10 sq.mm earth wire |
| 40 | S/F S.P. MCB DB:-Supplying & fixing following way single pole neutral, sheet, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper busbar, neutral busbar, earth bar, din bar, detachable gland plate,interconnections, phosphatized & powder painted including earthing etc. as required. (But wihtout MCB/RCCB/Isolator)8 way, Double Door |
| 41 | S/F T.P. MCB DB:-Supplying & fixing following way, Three pole neutral, sheet, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper busbar, neutral busbar, earth bar, din bar, detachable gland plate,interconnections, phosphatized & powder painted including earthing etc. as required. (But wihtout MCB/RCCB/Isolator)6 way (4+18), Double door, Horizontal type |
| 42 | S/F \"C\" series, MCB:-Supplying & fixing following, 240 volt, \"C\" series, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing & commissioning etc, as required.6/32 amps, Single pole |
| 43 | 40 amps, DP |
| 44 | 6/32 amps, TPN |
| 45 | S/F celling rose:-Supplying & fixing 2 pin 5 amps, celling rose on the existing, juction box/ wooen blockincluding connection etc. as required. |
| 46 | S/F Dingdong Call Bell:-Supplying & fixing dingdong call bell suitable for D.C/A.C single phase, 230 volts, complete as required. |
| 47 | ITC fluorescent fitting directly on surface:-installation, testing & commissioning of pre-wired, fluorescent fitting/ compact fluorescent fitting of all types, complete with all accessories & tube etc. directly on celling/ wall, including connection with 1.5sq. mm, FR PVC insulated, coppr cond |
| 48 | ITC ceilling fan:-Installation, testing & commissioning of ceilling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FR PVC insulated, copper coductor, single core cable etc, as required. |
| 49 | Telephone wiring in existing conduit:-Supplying & drawing following pair, 0.5 sq. mm FR PVC insulated copper conductor, unarmoured telephone cable in the existing surface. Recessed PVC conduit as required.2 pair |
| 50 | TV Cable in existing conduit:-Supplying & drawing co-axial TV cable RG-6 grade copper conductor, pe insulated, with PVC sheath in the existing surface/recessed PVC conduit as required. |
| 51 | 5/6 amps, one way switch |
| 52 | 3 pin 5/6 amps, socket outlet |
| 53 | Telephone socket with shutter outlet |
| 54 | TV antenna socket outlet |
| 55 | S/F PVC/ G.I Boxes:-Supplying & fixing PVC/ G.I box of following sizes on surface or in recess withsuitable size of phenolic laminated sheet cover infront including painting etc. ad required.75 mm X 75 mm X 50 mm deep/ (4\" X 4\") |
| 56 | ITC exhaust fan upto 450 mm sweep:-Installation of exhaust fan upto 450 mm. sweep in the existing opening, including making the hole to suit the size of the above fan, making good the damage, connection, testing, commssioning etc. as required. |
| 57 | S/F PVC conduit:-Supplying & fixing of following sizes PVC conduit along with accessories in surface/ recess includingcutting the wall & making good the same in case recessed conduit as required.20 mm |
| 58 | S/F batten holder:-Supplying & fixing batten/ angle holderincluding connection etc. as required. |
| 59 | LED tube with Batten (18w):Supply erection &commissioning of wall mounted LED 18w + batten &all accessories as required (make-Bajaj-model BLRB-DB 118 or Equivalent) |
| 60 | Providing filling fixing & testing of (Esential)T2W LED lump 12W in existing baitan / angle holder (make :- Model no. Cyska, model SSK12W CR EQUIVALENT) |
| 61 | LED Flood light 60 LED :Supply erection & commissioning of flood light lumineire with high pressure diecast housing (60W highpower LED as light source) with protection IP 86 (make Bajaj Model BJFL 60W LED or Equivalent) |
| 62 | Supply of Exhaust Fan fixing of 12\" dia (mastal) exhaust fan in existingin existing opening and fittings as required. |
| 63 | Supply of ceiling Fan fixing of 48\" (1200mm) Sweep celling fan with electronic regulator including connection with 1.5 sq.mm copper wire, down rod all accessories as required. Make- cromton / hevells / GEC. |
| 64 | Providing and fixing G.M non return valve Horizontal/Vertical type of approved quality as per specification of E/I.Horizontal - 32mm dia |
| 65 | Vertical- 32mm dia |
| 66 | 40 mm dia |
| 67 | 25 mm dia |
| 68 | Supplying, fitting and fixing the following items complete with all materials as per specification and direction of E/I.Mirror (600 x 450 mm) |
| 69 | C.P brass dish container medium quality with screw and hinges etc. |
| 70 | Supplying the following bathroom fitting all Complete V.I.P bib cock long thread V.I.P |
| 71 | Pilar cock (longneck) V.I.P |
| 72 | Angular Stop Cock (long Thread) |
| 73 | Paper Holder V.I.P |
| 74 | C.P brass tower rail |
| 75 | C.P btass sop dish |
| 76 | Suppling, fitting and fixing viterous white glazed earthen ware I.W.C of parry Hindustan or any other I.S.S approved make with 100 mm H.C.I \"P\" trap 15 liters C.I pull and let go flushing cistern of names or other I.S.S equivalent make, complete with all fitting, C.I or C.C Brackets 32 mm 580 mm long With 12.5 Liter Low Level P.V.C |
| 77 | Suppling, fitting and fixing flat back or angular, lipped frontviterous white glazed earthen ware urinal of Hindustan of parry Hindustan or any other I.S.S approved make with5 liters C.I automatic flushing cistern of reliance for any other I.S.S approved make with all fittings with C.I. or R.S. brackets, standard size G.I. flush pipe with fitting clamps 15mm C.I. body brass spindle stop cock of approved qulity wight not less than 400 grams 15mm P.V.C./Alkthene pipe 450mm long with brass coupling at both ends and doing plumber joints including painting of exposed part with two coats of approved pain over priming coat of red oxide, cutting wall and floor making good the same etc. all complete as per specificationand direction of E/I.standing corner (600mmx350mm) |
| 78 | Earth work in excavaion for laying of different type and size of R.C.C spun pipes with disposal of exacavted earth within initial lead and size of R.C.C soun pipe with disposal of excavated earth within initial lead and lift as per specification of E/I75 X 0.450 X 0.600 |
| 79 | Labour for alying, fitting and fixing NP2 R.C.C spun pipe with colars in lines, level and grad and providing approved jointing materials and joints properly filled to make them leakproof including providing sight rails, bonning rod, night guard, red light and barrier etc. all complet as per pecification and direction of E/I.150 mm dia R.C.C spun pipe |
| 80 | Suppling materials and lanours for constructing inspection chamber of designation class 75B bricks size 750mm deep, 600 X 450 mm internal dimension having 250 mm wall thickness in cement mortar (1:6) including 12 mm cementplaster (1:4) with punning on inside and cement plaster (1:6) with 600 X 475 mm G.I Cover with frame (weight not work in exacavation and 80 mm thick P.C.C (1:3:6) in foundation and rifilling all complete as per specification and direction of E/I |
| 81 | Providing and placing on terrace (at all floor levels) polyethylene water Storage tank ISI 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow Pipes but without fittings and the base support for tank. |
| 82 | Providing and fixing wash basin with C.I brackets, 15 mm C.P brass waste of standard pattern, including painting of fittings and brakets, cutting and making good the walls wherever require:White Vitreous china wash badin size 60x450 mm with a pair of 15 mm C.P brass pillar tap |
| 83 | Providing and fixing stainless Steel A ISI 304 (18/18) kitchen sink as per IS : 13983 with C.I brazsckets and stainless Steel plug 40 mm, including Painting of fitting and brackets, cutting and making good the walls wherever required: Kirchen sink without drain board610x460 mm bowl depth 200 mm |
| 84 | Providing & fixing chlorinated polyvinyl chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fitting, includingfixing the pipe with clamps at 1.00 m spacing this includes jointing of pipes & fittings with one step CPVC solvent cement and testing of koints complete as per directionInternal work - Eaposed on wall25 mm nominal outer dia Pipes |
| 85 | 32 mm nominal outer dia Pipes |
| 86 | Providing & fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fitting,I/C fixing the pipe with clamps at 1.00 m spacing this includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing direction of engineer in charge. Concealed work, including cutting chasesand making good the walls etc.15 mm nominal outer dia Pipes |
| 87 | 20 mm nominal outer dia Pipes |
| 88 | Providing and fixing PTMT grating of approved quality.C.P GratingsCircular type - 100mm dia |
| 89 | Making soak pit 2.5 m diameter 3.0 metre deep with 45x45 cm dry brick honey comb shaft with brick and S.W drain pipe 100 mm diametre, 1.8 m long complete as perstandard design.Withcommon burnt clay F.P.S (non modular) brick ofclass designation7.5 |
| 90 | Providing & laying of 110 mm dia. P.V.C pipe for outlet of water to outlet drain including all accessories I.E lubricants, solvent cement, clamp, ring, sockets etc. (Supreme.R.) 110 mm |
| 91 | Providing & fixing PVC pipe fitting with all accessories (Supreme Make) i) 110 mm Door Tee (Supreme) PVC |
| 92 | ii) 110 mm Plain Tee (Supreme) PVC |
| 93 | iii) 110 mm Door Bend (Supreme) PVC |
| 94 | Sub Total MEP Works |
| 95 | Carriage of matertials |
| 96 | Cement |
| 97 | Sand |
| 98 | Aggregate |
| 99 | Steel |
| 100 | Bricks |
| 101 | Non Schedule Items |
| 102 | Civil Work |
| 103 | Providing and fixing, designing acoustic panelin hall /audotirium as per design to avoid echo.(Rate=740/.45/.45) |
| 104 | Outdoor Fountain with coloured lighting \"Fountain |
| 105 | Berger wall putty powder packibg size 1KG |
| 106 | Sub Total Civil Work |
| 107 | MEP |
| 108 | Main painel (Floor mounting at Ground Floor):- |
| 109 | Power Distribution Boand (FDB of GL)- Supplying designing, manufacturing, installation testing, filling, fixing and commissioning in correct alignment position, effecting proper connection of all incomers an outgoing of PCB panel of 14 SWG CRCA Sheet (2mm) steel IP-54 Floor mounting cubical type LT panel suitable for operation on 415v, 50Hz, 3Ph, AC Supply and fauil level 15ka Approxmate Size (Shal be given at the time of work oder) with front operated construction including seperate fabrication attangement for fixing of switch gears and meters. |
| 110 | The sheet sleel under go minimum geven lanks freatment followed by finishing poder coating of minimum 60 microns thickness duly compart mentalized with looking arrangment duly fixed on base channel size 100mm x 75mm x 6mm having accessories mounted inside cubicate panel, earthing with 2 Nos. of earth studs. |
| 111 | All opening shall be covered by solt rubber gaskit, anciosure shail be galvenished, panel shall have suitable cable entry from top and bottom and suitable arrangment for multiruns aluminium cable for MCCB. |
| 112 | Incomers |
| 113 | 100A, 16KA FP MCCS-1 no with final rotary handel with thermo magnatic release- for JSEB |
| 114 | Outgoings |
| 115 | 3- nos-40A, 10KA DP MCS with front rotary handle with thermo magnatic relese- for PDE+spare |
| 116 | 6-nos-40A, 10KA FP MCS lighting DSs+Spang |
| 117 | Analogue type Ammetesr (0-400A) of 96sq.mm with selector switch. Make :- AUE/ Universal / L&T/ Eama. |
| 118 | Analogue type Ammetesr (0-500A) of 96sq.mm 1 no with selector switch. Make :- AUE/ Universal / L&T/ Eama. |
| 119 | LED indicatore (RYS) of 220V 1 Set of 3 nos Make:- ESSEN/ L&T- ESBEE / Biney / Taknit |
| 120 | Bakalite fuse base with HRC fuse 20A. 1 Set of 2 nos Make :- Lagrand/ L&T / Schinder. |
| 121 | GT 600SVA -5 cless one epoxy resin cost GT Sel Make:- Kabpa / Matrix/ SD Electricals/ EPICAST |
| 122 | 100A Bus Bar |
| 123 | SB collection 3 seater public place seating chair of SS 304 with arm and backrest withwouth cushion |
| 124 | Modern Office Furniture Executive Table of Three layer prelaminated particle board(Wood Product) of grade II type II of IS 12823/Latest 1800 millimeter 900 millimeter 750 millimeterModern Office FurnitureR(Table) |
| 125 | Unbranded Heavy Duty Curtains Polar PVC Strip Curtain 2 mm per stripNA |
| 126 | SUPREME Stainless Steel 304 Curtain Pipe, Sider and mounting bracket, Length 4 MeterSUPREMER(PFF/01-85 |
| 127 | Unbranded Stainless Steel 304 Curtain Pipe, Sider and mounting bracket, Length 1 MeterNA(CURTAIN WALL BRACKET (SIDER |
| 128 | MEGA PROFESSIONAL AUDIO Two Way PA Speaker, Warranty 1 YearsMEGA PROFESSIONAL AUDIOR(GOVT. P - 500T |
| 129 | FALCON PVC Speaker cable, Warranty 1 yearFALCONR(ROND-173 |
| 130 | Smartedge Analog PA Amplifier, Number of Channels 2SmartedgeR(SEPA-800) |
| 131 | Hugo Techno Wired Cardioid MicrophoneHugo TechnoR(HT-MIC-441 |
| 132 | Add GST @12% |
| 133 | Labour Cess 1% |