| 1 | Description of Material |
| 2 | S.T. Pole (SP-55) 11.0 Mtr. |
| 3 | S.T. Pole (SP-37) 9.50 Mtr. |
| 4 | Earth Rod Complete |
| 5 | Earth Wire 7/16 SWG |
| 6 | Stay Rod Complete 20 mm |
| 7 | Stay Wire 7/10 SWG |
| 8 | L.T. Circuit 500V/500A |
| 9 | L.T. XLPE Cable 1X400 Sq. mm |
| 10 | 11 KV XLPE Cable 3X300 Sq. mm (200x2+50x2+250x2+500x2)+10% |
| 11 | 11 KV 3x300 Sq. mm St. Th. Joint Box |
| 12 | 11 KV 3x300 Sq. mm Outdoor Cable Box |
| 13 | 11 KV 3x300 Sq. mm Indoor Cable Box |
| 14 | 11 KV XLPE Cable 3X70 Sq. mm |
| 15 | 11 KV 3X70 Sq. mm Outdoor Cable Box |
| 16 | 11 KV 3X70 Sq. mm Indoor Cable Box |
| 17 | M.S. Channel 100x50x6 mm 2.4 Mtr. Long (36 Nos.) |
| 18 | M.S. Angle 65x65x6 mm for B Pannel and C Pannel Structure |
| 19 | Alu. Crimping Lug 300 Sqmm |
| 20 | Alu. Crimping Lug 400 Sqmm |
| 21 | 11 KV Pin Insulator |
| 22 | 11 KV Pin with Nut for Pin Insulator |
| 23 | M.S. Clamp 4 1/2\" (50x6) mm |
| 24 | M.S. Clamp 5 1/2\" (50x6) mm |
| 25 | M.S. Clamp 6 1/2\" (50x6) mm |
| 26 | C.I. Packing 5 1/2\" |
| 27 | C.I. Packing 6 1/2\" |
| 28 | G.I. Pipe 6\" dia 3 Mtr. Long Pcs. With M.S. Clamps. |
| 29 | L.T. Armoured XLPE Cable 31/2 X 70 Sq. mm |
| 30 | L.T. Armoured XLPE Cable 31/2 X 240 Sq. mm |
| 31 | Cable end termination using Total double compersation brass gland and climping type almunium thimble 3.5x240 sq.mm XLPE Cable |
| 32 | Cable end termination using Total double compersation brass gland and climping type almunium thimble 3.5x70 sq.mm XLPE Cable |
| 33 | Supply of Outdoor type feeder piller panel to be made of 2mm CRCA sheet & Covers will be 1.6 mm CRCA sheet duly power paint including suaitable foundation with 400 amp. Aluminim Bus bar (Type B-1 Incomer 250 amp TP MCCB 1 no. Outgoing 63 amp. TP MCCB 6 No.) |
| 34 | Locable Distribution box of size 450 x 400 Sq.mm with bus bar 100 Amp. TPN to feet upto 10 houses (C Type pannel). |
| 35 | Al Cable Armoured cable 2x10 sq.mm |
| 36 | Al. Cable Armoured cable 4x25 sq.mm |
| 37 | G.I. Pipe 40\" dia. |
| 38 | G.I. Pipe 50\" dia. |
| 39 | PVC Pipe 40 mm dia. |
| 40 | PVC Pipe 50 mm dia. |
| 41 | Arial Bunched Cable |
| 42 | Holding Clamp for round Pole 5/s\" (50x6) |
| 43 | Suspension Clamp with Eye Hook & Holding Clamp |
| 44 | Dead End Clamp with Eye Hook & Holding Clamp |
| 45 | Piercing Connector 150-25 Rpm |
| 46 | L. f. Bare Neutral Conector |
| 47 | L.T. Distribution Box Three Phase with Clamp Set |
| 48 | Ferrule Connector |
| 49 | Bracket L.T. 18\" |
| 50 | M.S. Flat 60x6 mm |
| 51 | ACSR Dog Conductor. |
| 52 | Disc fitting 70 KN B&S Type |
| 53 | 11 KV Disc Insulator T&C Type 70 KN |
| 54 | Danger Board |
| 55 | Barbed Wire |
| 56 | Nut & Bolts 5 suit 3 inch. |
| 57 | Particulars of works |
| 58 | L/c for Loading carriage and unloading of all items like cable, Pole andall related accessorses from Kesco store to work site or vice -versa |
| 59 | L/C for Erection of Double Pole by digging of Pit |
| 60 | L/c for Grouting of S.T Pole including cost of Civil material as per standardSpecification. |
| 61 | L/c for Making of Pole plinth including costof civil Material |
| 62 | L/c for Painting of S.T Pole including cost of paint |
| 63 | L/c for Erection of Earth Road complete |
| 64 | L/c for Fixing of M.S Channel on newly erected D/pole |
| 65 | L/c for Mounting of Pin Insulator on erected Pole |
| 66 | L/c for Chopping of TreeBranches for clearing the route of 33/11 KV O.H Line |
| 67 | L/e for Fabrication/Modification of different M.S. Item as per site requirement. |
| 68 | L./c for Deep bore pipe earthing (G.1. Pipe 40 mm dia, B-Class. 40 \"6 ieet, socket, cutter and MS flat/M.S. Wire with nut & bolt) with connection of pipe to distribution transformer. Nutreral or Body all material will be provided by Constractor. |
| 69 | L/c for Providing and laying of HDPE 160 mm pipe with depth of 1,2 to 2,0 Mtr. or as per site condition through Horizontal! drilling Method at road crossing for laying of cable (HDPE pipe provided by contractor). |
| 70 | L/cfor Laying of 11 KV Cable via above laid HDPE pipe through HDD method/manual method. |
| 71 | L/c for Laying of L.T. 31/200 to 3\"/2x240sq.mm XLPE Cable via above laid HDPE pipe through manual method. . |
| 72 | L/c for layingof 11 KV XLPE Cable Through HDD method without Pipe. |
| 73 | 7 IL/c for providing and erection of HTPB alongwith grouting and making suitable plinth. |
| 74 | L/c for dismentalling and relaying of AB cable from existing distribution transformer to newly transformer shifted loaction. |
| 75 | L/e for laying of AB Cable as per standred Specification. |
| 76 | L/c for digging of trench 0.06 Mtr. To 0.09 Mtr. Deep and 0.3 Mtr. Wide for laving of L.T. XLPE Cable. |
| 77 | L/c for laying and erection of L.T. 31/2x70 and 31/2x240 sq.mm XLPE cable in above digged trench overing with bricks and sand as per standredSpecification. |
| 78 | L/c for laying of G.I. Pipe 40 mm dia to houses (external area). |
| 79 | L/c for laving of G.I. Pipe 50 mm dia to houses (external area). |
| 80 | L/c for lay ing of under ground PVC Pipe 40 mm dia. |
| 81 | L/e for laying of under ground PVC Pipe 50 mm dia. |
| 82 | L/c for Painting of Steet Structure with two coats of Primer and two coats of enamel paint. |
| 83 | L/c for erection and grouting of B Type Pannels. |
| 84 | L/c for erection and grouting of C Type Pannels. |
| 85 | L/c for making of Cable termination Joint. |
| 86 | L/c for mounting of Cable termination Joint with pipe. |
| 87 | L/c for mounting of Cable termination Joint without pipe. |
| 88 | L/c for digging of trench and making St. Th. Joint Box. |
| 89 | L/c for laying of Annoured Cable 2x10 sq.mm. |
| 90 | L/c for laying of Armoured Cable 4x25 sq.mm. |
| 91 | L/c for dismentalling of S.T. Pole. |
| 92 | L/c for dismentalling of ACSR Mixed Conductor. |
| 93 | L/c for dismentalling of A.B. Cable. |
| 94 | L/c for dismentalling of M.S. Channel, V type cross arm and M.S. Angle. |
| 95 | L/c for construction of T/F Plinth size 1.2X1.2X1.2 Cubic Mtr (including civil material and 6 feet (1.5 feet long 4 Pcs.) M.S. Angle size 65x65x6mm) will be solid with brick work 75 mm thick C.C. in ratio 1:4:8 with cement coarse sand and brick ballast |
| 96 | L/c for fabication and erection of T/F fencing of frame size 3X2.5 mtr including cost of M.S. Angle size 40X40X5 mm and M.S. Flat size 35X5 mm fixing of welded steel wire fabric on steel frams by welding of 10 SWG wire fabric inculding painting of two coats of paint on iron based surfaces with ready mixed paint to give bus green shade including of oil and dust |
| 97 | L/c for Providing and fixing of concrete stone Route marker of 300 mm width X 150 mm thick X650 mm height in embedded in earth at least 300 mm below and 350 mm above ground level at the distance of approx 100 Mtr at long the length of the cable with RCC concreting as per standardspecification. Route marker should be with name of company, distance from marker to cable and cable depth with feeder name marked with Arrow singn. |
| 98 | L/c for shifting and erection of existing distribution transformer from existing plinth /D. pole to newly erected plint / Dpole |
| 99 | L/c for macking suitable plint for ACB for existing distrbution transformer at near by newly shifted transformer and shifting and erection of ACB on newt N erected ACB plinth. |
| 100 | L/c for Connecting of Newly constructed HT/L.T. 11 KV network including testing, commissioning and energisation of the same completely. |
| 101 | L/c for Preparation and submission of 03 Set of complete layout drawing with GIS mapping as per actual cable routing, showing road crossing HDPE pipe/M.S. Pipe sleeving jointing locations, markers etc,. |