Defence Statutory Bodies & Commissions/Committees Closing in 0 days TDR #32731950

Petty Repair And Day To Day Maintenance Of E And M Works In Zone-A At Defence Lab Jodhpur

Issued by Statutory Bodies & Commissions/Committees · jodhpur, Rajasthan
Tender Value
5 Lakhs
Estimated cost
Bid Submission
12 Jul 2022
0 days left
EMD
10000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
jodhpur → Rajasthan
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Petty Repair And Day To Day Maintenance Of E And M Works In Zone-A At Defence Lab Jodhpur

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 05-Jul-2022 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 12-Jul-2022

BOQ

Name of Work : PETTY REPAIR AND DAY TO DAY MAINTENANCE OF E&M WORKS IN ZONE-A AT DEFENCE LAB JODHPUR
Sl. No. Item Description
1S&F in repairsSwitch piano 6 Amp flush type single pole one way with ISI marked,complete all as specified and directed by engineer in charge. NOTE :-(Applicable to All Items Sr No:-01 to 33 ) (i) Contractor or his/her representative will report to E/M complaint cell with 01 Electrician and 01 Helper along with T&Pto receive complaints in the morning 0900 hrs with necassary daily stores as requested to attend day to day complaints (ii) The complaints should be attended & completed within 72 Hrs after receiving the complaint slip failing which a penality of Rs 500 /-will be recovered for each complaint from the contractor payment (iii) The cost of Electrician (Skilled ) & Helper(Semiskilled ) should be deemed to be included in the item rates quoted by the contractor,nothing will be paid extra for hiring the skilled labour (iv) The contract can be made operational for 09 months irrespective of qty provided in BOQ (v) The contractor shall note that the electrician and the helper should have their individual bycycle/vehicle to attend the complaints(vi) The contractor shall note that electrician and helper employed should have basic/keypad mobile with them for the easy communication with E/M complaint cell/user/JE/Engr-in-charge.
2S&F in repairsSwitch piano 16 Amp flush type single pole one way with ISI marked, complete all as specified and directed by engineer-in-charge.
3S&F in repairsSocket outlets 6 Amps 2-in-1, 3 pin 230 V AC flush type, complete all as specified and directed by engineer-in-charge.
4S&F in repairsSocket outlets 6/16 2-in-1,3 pin Amps, 230 V AC flush type, complete all as specified and directed by engineer-in-charge.
5S&F in repairs Switch socketcombination 6 Amps 2-in-1, 3 pin 230 V AC flush type, complete all as specified and directed by engineer-in-charge.
6S&F in repairs Switch socketcombination 6/16 Amps 2-in-1, 3 pin 230 V AC flush type, complete all as specified and directed by engineer-in-charge.
7S&F in repairs Ceiling rose, 3 phase / PVC / Polycarbonate, isolated body complete all as specified and directed by engineer-in-charge.
8S&F in repairs 3 pin,6 Amps plug top, 230 V ACcomplete all as specified and directed by engineer-in-charge.
9S&F in repairs 3 pin,16 Amps plug top, 230 V ACcomplete all as specified and directed by engineer-in-charge.
10S&F in repairs MCB SP ‘C’ curve, 10KA6 to 32 ampsincluding necessary connection complete all as specified and directed by Engineer-in-charge.
11S&F in repairs MCB SP ‘C’ curve, 10KA 40 to 63 amps including necessary connection complete all as specified and directed by Engineer-in-charge.
12S&F in repairs MCB SPN ‘C’ curve, 10KA40 to 63 ampsincluding necessary connection complete all as specified and directed by Engineer-in-charge.
13S&F in repairs MCB TP ‘C’ curve, 10KA 25 to 63 ampsincluding necessary connection complete all as specified and directed by Engineer-in-charge.
14S&F in repairs MCCB Thermal magnetic protection type, 16KA, 125 amps,3 poleincluding necessary connection complete all as specified and directed by Engineer-in-charge.
15S&F in repairs Single pole enclosure with two pin and earth plug and socket with one single pole MCB 20 Amps complete all as specified and directed by engineer-in-charge.
16S&F in repairs Factory made DB SPN8 way double door with 200 Amps rated bus bar concealed in wall IP 43 protection for fixing MCB complete all as specified and directed by Engineer-in-charge.
17Supply and fix 2.50 SqmmFRLSPVC insulated multi-stranded copper conductor, single core cable for connections including taking down old unserviceable connections complete all as specified and directed by engineer-in-charge. Note:- Each wire shall be measured.
18Supply and fix 4.0 SqmmFRLSPVC insulated multi-stranded copper conductor, single core cable for connections including taking down old unserviceable connections complete all as specified and directed by engineer-in-charge. Note:- Each wire shall be measured.
19M&L for fixing PVC white rectangular/pipe casing capping of 20/25 mm bore/width size complete all as specified and directed by engineer-in-charge.
20Taking down Ceiling fan/exhuast fan, sealing cable end dismantling blades and removing fan and blades to store for refixing complete all as specified and directed by Engineer-in-charge
21M&L for repair of Ceiling fan 1200/1400 mm sweep of any make obtained from above item,rewinding with super enamelled copper wire, baking, casting, assembling, oiling, greasing cleaning slot, over hauling & replacement of defective capacitor, nut bolts washer etc including painting complete all as specified and directed by Engineer-in-charge.
22M&L for repair of Exhaust fan of any sweep of any make obtained from taking down,rewinding with super enamelled copper wire, baking, casting, assembling, oiling, greasing cleaning slot, over hauling & replacement of defective capacitor, nut bolts washer etc including painting all as specified and directed by Engr-in-charge.
23Supply and fix in repairs suitable Step type electronic fan regulator flush type on the existing phenolic laminated sheet etc complete all as specified and directed by engineer in charge.
24S&F in repairs capacitor 2.5 MFD suitable for ceiling fan / exhaust fan / wall mountaining fan of any sweep complete all as specified and directed by Engineer-in-charge.
25S&F in repairs heating elementISI marked suitable for existing 25/35 litre capacity geyser complete all as specified and directed by engineer-in-charge.
26S&F in repairs, thermostate ISI marked suitable for existing 25/35 litre capacity geyser complete all as specified and directed by engineer-in-charge.
27S&F in replacementassembly of existing make of stainless steel body geyser 25/35 litre capacitycomplete all as specified and directed by engineer in charge.
28S&F in repairs Batten holder sutable for existing LED bulbISI marked complete all as specified and directed by engineer in charge.
29S&F in replacement LED bulb of 9watt,6500K complete all as specified and directed by Engineer-in-charge.
30Supply & Fixing in replacementLED light fitting 1x10 W Bulk Head lumanaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed by Engineer-in-charge. Make:Bajaj/Crompton /Havells.
31S&F in repairs straight linear,white two feet 10W LED light with batten connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed by Engineer-in-charge.
32S&F in repairs radiance ray plus LED batten for home 2400 lumens cool day light 24 watt, operating voltages:140-270 volts environmental friendly, energy efficient ready to use pack complete all as specified and directed by Engineer-in-charge.(Crompton cat part No:LDRR24-CDL or equivalentmake as approved by AGE(I) R&D Jodhpur)
33S&F in replacement LED light fitting 1X20 Watt AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed by Engineer-in-charge.

AI Tender Summary

OUR REF NO 32731950
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 5 Lakhs
LAST DATE 12-07-2022
Authority
Authority Name Defence Research And Development Organisation
Work Description Petty Repair And Day To Day Maintenance Of E And M Works In Zone-A At Defence Lab Jodhpur
Basic Detail
Tender No 8482/E8
Bidding Type Tender
Location
City jodhpur
State Rajasthan
Key Dates
Publish Date 05 Jul 2022
Submission Date 12 Jul 2022
Open Date 14 Jul 2022
Finance
Tender Value 5 Lakhs
Tender Fee 500
EMD 10000
Exemption Not Available
Document List
BOQ_594459.xls
PS.pdf
Tendernotice_1.pdf
2d98fe23-b73f-49cc-9dd3-03797c7b2990.html

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 05, 2022
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 12, 2022
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Completed
Jul 12, 2022
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Jul 14, 2022

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
xls

BOQ_594459.xls

pdf

PS.pdf

pdf

Tendernotice_1.pdf

html

2d98fe23-b73f-49cc-9dd3-03797c7b2990.html

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders