Improvements To The Ductable Ac System Of Sri Sundharaja Swami Temple In Sri Pat, Tiruchanoor , Sitc Of Double Skin Vertical Floor Mounted Dx Ahu With 10Mcron-50Mm Thick Pre Filter, Coil And Fan Section, 25Mm Thick Puff Insulation, Panel Inner 0.6Mm, tirupati-Andhra Pradesh

Tirumala Tirupati Devasthanams-TTD has published Improvements To The Ductable Ac System Of Sri Sundharaja Swami Temple In Sri Pat, Tiruchanoor , Sitc Of Double Skin Vertical Floor Mounted Dx Ahu With 10Mcron-50Mm Thick Pre Filter, Coil And Fan Section, 25Mm Thick Puff Insulation, Panel Inner 0.6Mm. Submission Date for this Tender is 02-07-2022. Electrical Condenser Tenders in tirupati Andhra Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

32717480
Improvements To The Ductable Ac System Of Sri Sundharaja Swami Temple In Sri Pat, Tiruchanoor , Sitc Of Double Skin Vertical Floor Mounted Dx Ahu With 10Mcron-50Mm Thick Pre Filter, Coil And Fan Section, 25Mm Thick Puff Insulation, Panel Inner 0.6Mm
Open Tender
Indian
Andhra Pradesh
tirupati
02-07-2022

Tender Details

Improvements To The Ductable Ac System Of Sri Sundharaja Swami Temple In Sri Pat, Tiruchanoor , Sitc Of Double Skin Vertical Floor Mounted Dx Ahu With 10Mcron-50Mm Thick Pre Filter, Coil And Fan Section, 25Mm Thick Puff Insulation, Panel Inner 0.6Mm Gi Plain And Outer 0.6Mm Thick Pre Coated, Aluminium Extruded Frame With Nylon Corners With Hollow Profile, Didw Forward Curved Fan Of Nicotra / Kruger Make, 3Ph, Ie2 Motor Of Cg / Abb, 3 / 8 Inch Dia, 6 Row Dx Cooling Coil With Aluminium Finned Copper Tube Along With Ss Drain Pan. Capacity: 3200 Cfm, 50Mmsp, Supply Installation Testing Commissioning Of 8.75Tr Air Cooled Condensing Unit Consisting Of Scroll Compressor, Copper Condenser Coil Of Copper Tubes And Blue Hydrophilic Coated Aluminium Fins, Condenser Fans, Etc. Suitable For Operating An Eco-Friendly Refrigerant R-407C Including Necessary Accessories Like Rubber Pads. Make: Voltas, Supply And Installation Of Suitable New Thermostatic Expansion Valve And Catch All Filter Driers Along With Necessary Fittings, 18G, Hard Drawn Copper Refrigerant Piping, Duly Insulated With Closed Cell Elastomeric Nitrile Rubber Insulation, Class-O, Covered With Complete With Necessary Fittings. 5 / 8 Inch ( 15.8Mm ) Liquid Line, 18G, Hard Drawn Copper Refrigerant Piping, Duly Insulated With Closed Cell Elastomeric Nitrile Rubber Insulation, Class-O, Covered With Complete With Necessary Fittings. 1 1 / 8 Inch ( 28.5Mm ) Suction Line, Supply And Charging Of Additional Refrigerant R407c, Pressure Testing, Vaccumising And Commissioning Of The Units, Integration And Uploading Software In Existing Microprocessor By Voltas Engineer, Dismantling, Shifting Of Air Handling Unit And Condensing Units, Buy Back Of Old Ahu And Condensing Units

Key Value

Document Fees
Refer document
EMD
INR 5000.0 /-
Tender Value
Refer document

BOQ Items

Sl. No. Item Name
1SITC of Double skin vertical floor mounted DX AHU with 10mcron-50mm thick pre filter, coil and fan section, 25mm thick puff insulation, panel inner 0.6mm GI plain and outer 0.6mm thick pre coated, aluminium extruded frame with nylon corners with hollow profile, DIDW forward curved fan of Nicotra / Kruger make, 3ph, IE2 motor of CG/ABB, 3/8 inch dia, 6 row DX cooling coil with aluminium finned copper tube along with SS drain pan. capacity: 3200 cfm, 50mmSP
2Supply Installation testing commissioning of 8.75TR Air cooled condensing unit consisting of scroll compressor, copper condenser coil of copper tubes and blue hydrophilic coated aluminium fins, condenser fans, etc. suitable for operating an eco-friendly refrigerant R-407C including necessary accessories like rubber pads. MAKE: VOLTAS
3Supply and installation of suitable new thermostatic expansion valve and catch all filter driers along with necessary fittings
418G, hard drawn copper Refrigerant piping, duly insulated with closed cell elastomeric nitrile rubber insulation, class-o, covered with complete with necessary fittings. 5/8 inch (15.8mm) Liquid Line
518G, hard drawn copper Refrigerant piping, duly insulated with closed cell elastomeric nitrile rubber insulation, class-o, covered with complete with necessary fittings. 1 1/8 inch (28.5mm) Suction Line
6Supply and Charging of additional Refrigerant R407C
7Pressure testing, Vaccumising and commissioning of the units, Integration and uploading software in existing microprocessor by Voltas engineer
8Dismantling, shifting of Air handling unit and condensing units
9Buy Back of Old AHU and Condensing Units