8122 / Sar-36 / 2022-23 Repair / Maintenance To Fire Fighting And Fire Alarm System, Lift, Boom Barrier And Eot Crane At Af Stn Sarsawa Under Ge ( Af ) Sarsawa, sarsawa-Uttar Pradesh

Military Engineer Services-MES has published 8122 / Sar-36 / 2022-23 Repair / Maintenance To Fire Fighting And Fire Alarm System, Lift, Boom Barrier And Eot Crane At Af Stn Sarsawa Under Ge ( Af ) Sarsawa. Submission Date for this Tender is 01-09-2022. Cranes Tenders in sarsawa Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

32717128
Corrigendum : 8122 / Sar-36 / 2022-23 Repair / Maintenance To Fire Fighting And Fire Alarm System, Lift, Boom Barrier And Eot Crane At Af Stn Sarsawa Under Ge ( Af ) Sarsawa
Open Tender
Indian
Uttar Pradesh
sarsawa
01-09-2022

Tender Details

8122 / Sar-36 / 2022-23 Repair / Maintenance To Fire Fighting And Fire Alarm System, Lift, Boom Barrier And Eot Crane At Af Stn Sarsawa Under Ge ( Af ) Sarsawa

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 01-Jul-2022 AMDT02 Terms and Conditions 08-07-2022
2 01-Jul-2022 AMDT01 BOQ 08-07-2022
3 08-Jul-2022 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 15-07-2022
4 15-Jul-2022 AMDT03 Date 20-07-2022
5 23-Jul-2022 AMDT04 Date 01-09-2022
6 30-Jul-2022 AMDT05 Other 01-09-2022

Key Value

Document Fees
INR 500 /-
EMD
INR 50000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: REPAIR/MAINT TO FIRE FIGHTING & FIRE ALARM SYSTEM,LIFT, BOOM BARRIER AND EOT CRANE AT AF STN SARSAWA UNDER GE(AF) SARSAWA
Sl. No. Item Description
1M & L for periodic inspection/ Servicing of 2 Ton capacity EOT Crane of any make installed at different building/location in Airforce Station Sarsawa, making the crane in fully serviceable condition complete all as specified and directed as under:- (A) LONG TRAVERSE MOTION- (i) Checking gear box oil level , checking and rectification of leakage if any and filling with new gear box oil upto required level. (ii) Checking function of all LT Brakes of any capacity and making adjustment for proper working including replacement of worn out parts if any. (iii) Checkingof LT Wheels for any abnormal sound and checking mounting and fixing arrangement. (iv) Checking of grase in geared coupling and tightening of nut and bolts etc. (v) Checking of LT Motion cut-off at the extreme ends of bay length with L.T limit switches (vi) Checking drive shaft and coupling including tightening of nut and bolts. (vii) Checking of terminal connections of all LT motors and tightening properly including replacing burnt / overheated cable ends if any. (B) CROSS TRAVERSE MOTION (i) Checking gear box oil level , checking and rectification of leakage if any and filling with new gear box oil upto required level. (ii) Checking function of CT Brakes of any capacity and making adjustment for proper working including replacement of worn out parts if any. (iii) Checkingof CT Wheels for any abnormal sound and checking mounting and fixing arrangement. (iv) Checking of grase in geared coupling and tightening of nut and bolts etc. (v) Checking of CT Motion cut-off at the extreme ends of bay length with C.T limit switches (vi) Checking drive shaft and coupling including tightening of nut and bolts. (vii) Checking of terminal connections ofCT motors and tightening properly including replacing burntoverheated cable ends if any. (D) ELECTRICALS (i) Checking and tightening all electric connection (ii) Checking the contactors/ relays etc for overheating or flashing. (iii) Cleaning off all connection and control cables. (iv) Properly bunching the loose control cable. (v) Checking functioning of cable carriers. (E) GROUND MOTION CONTROL PANEL (i) Opening the push button control unit, checking all connection, replacing flashed/ over heated connections, general cleaning and checking all the functions, of the LT/CT/ Hoist motion push buttons and lights switch including reassembling the unit complete NOTE :- 1. Gear box oil shall be measured and paid separately.
2Supply only in replacement Gear box oilEP -230 for EOT crane complete all as specified and as directed.
3Supply only in replacement Brake oil for EOT crane complete all as specified and as directed.
4Supply and fix in replacement of old L.T / C.T D.S.L System in 2 TON capacity EOT Crane with New C-Track system with 4 wheel cable Trollies should be mounted on Angle Iron Brackets of suitable size duly clamped complete all as specified and directed by engg-in-charge.
5M&L in replacement of Flexible Cable of 01sqmm*14 core for Pendent Push Button Station from Main Panel to Push Button Station on Newly fixed ‘C’-Track system suitable for 02 ton EOT Crane complete all as directed.
6Supply and fix in replacement new pendent Push Button Station made out of MS Sheet, duly powder coated, and pre wired for 2 TON EOT Crane having 10 Nos Push Button of different color with NO+NC Contact Block. Push Button Station should be hanged with insulated Steel Wire Rope with ‘D’ clamps complete all as directed.
7M&L in fabrication of NEW Foundation Base for LT Motion Gear Box and LT Motor including drilling and bolting of high tensile bolts complete all as specified and directed. NOTE : (a) Base shall be fabricated by cutting MS Plate of min 10mm thick. (b) Welding work, if required shall be done by contractor at their own cost.
8M & L in replacement ofUnserviceable L.T and C.T Disc Brake with Newdisc brake of suitable size complete all as specified and directed. Make : Megtech/ Cranex/ Pethe
9M & L in replacement of L.T & C.T box type limit switch with lever complete for 2 TON EOT Crane complete all as specified and directed. Make : Megtech/ Cranex/ Pethe
10S&F in replacement multi standard copper conductor flexible (industrial cable) 1100 volts PVC insulted and sheathed cable of size 6sqmm 4 core complete all as directed.
11S&F in replacement multi standard copper conductor flexible (industrial cable) 1100 volts PVC insulted and sheathed cable of size 2.5sqmm 4 core complete all as directed.
12S&F in replacement multi standard copper conductor flexible (industrial cable) 1100 volts PVC insulted and sheathed cable of size 1.5sqmm 3 core complete all as directed.
13M & L in replacement of Main Electric Control Panel of 2 TON EOT Crane made out of M.S Sheet not less than 16 SWG duly powder coated Prewired with flexible copper cable of suitable size having 20% cushion duly Terminated with copper lugs and having Terminal Blocks mounted on channel. Panel should be fixed/ welded on the crane. Panel should have Main ON-OFF TPN MCCB 63 Amps rated. The Main Contractor should be 40 Amp rated 415/110 volts and Hoist Contractor should be 25 Amp rated-2 NOS, LT & CT Contractor should be 25 Amps rated having Coil Voltage 415/110 Volts-4NOS. Panel should have step down Transformer having input 415/output 110/36/24/12 Volts andvariable frequency drive3 phase suitable for hoist motor with DBR. Panel shall be made by C.P.R.I approved firm make of contractor, MCCB, MCB: Siemens/ L&T. Make of Panel R.T.F Automation/ Cranex Ltd/ Tricolite. (Note: Panel wiring Diagram 3 Copies shall be submitted for the approval of GE)
14M&L for replacement of 9mm steel wire rope of 6*36 FMC Construction duly tested for 2 ton EOT Crane complete all as directed. Make : Usha Martin/Mahadev Note: Necessary Test Certificate for steel wire rope shall be submitted by the contractor.
15S&F in replacement MCCB TPN 63 Amp rated fixed in CRCA sheet steel enclosure duly powder coated to be mounted on the wall with the help of fastners complete all as directed Make of MCCB:- L&T / Schneider
16M & L for radiography testing of crane main hook block by approved firm from BARC Mumbai complete all as specified and as directed. Note: Original film and testing report shall be submitted by the contractor.
17M&L for Load Testing of 2 TON capacity EOT Crane25% extra dead weight load complete all as specified and as directed. Note:- Necessary T&P and Dead Weight load should be arranged by contractor at site at their own cost.
18M&L for fixing box type TPN DSL System of 63 Amp rated capacity for main hanger gate. The box type DSL system should be mounted on angle iron brackets of suitable size duly clamped complete allas specified and directed by Engr-in-charge. Note : The cost angle iron brackets shall be included in the quoted rate.
19M&L for fixing 32 Amp rated TPN current collector for box type DSL System complete all as directed.
20Fabrication of MS bracket made out of angle iron / channel of suitable size for current collector / cables complete all as specified and directed
21Supply, fixing, testing & commissioning of AC drive, upto5.5kW V/F control operated on 3 phase 415 Volt AC for hoist control CT/LT motor of EOT crane complete all as specified and as directed.
22Supply, fixing and making all connection Rotary limit switch capacity 40 Amps 415 volts all as per existing for LT/CT/Hoist motion of 2 ton capacity crane, including taking down old unserviceable rotary limit switchcomplete all as specified and as directed.
23S&F in repairs, push button with element in push button box as per required colour codecomplete all as specified and as directed .
24S&F in repairs, power contactor 20 Amps with 2 NO + 2NCcomplete all as specified and as directed.
25M&L for re-winding of electric motor upto5 HP, 3 Phase 415 volt of any make after disconnecting motor electrically and mechanically systemfromthe elevated heightandtransporting to workshop for repairs, taking out burnt winding wire, cleaning the rotor and stator properly, rewinding the motor with super enameled copper winding wire as per existing gauge, varnishing /drying etc complete, replacing the ball bearings as per existing size, reassembling the motor, shifting and installing at original position , making electrical and mechanical connections and testing for proper working complete all as specified and as directed.
26S&F in repairs motor of capacity 2 HP/1.5 KWthree phase RPM 1420 suitable for electric operated motorised door complete all as specified and directed by Enineer-in ChargeMake : ABB
27S&F in repair of Gear box matching with motor given at ser item no 26 above and matching with existing make complete all as specified and directed.
28S&F in repairs Hanger door Iron roller wheel ofsize upto 300mm x 75mmas per exisiting size complete all as specified and directed.
29S&F in repairs of Hanger door Iron roller free wheel of size upto 300mm x 75mm as per exisiting size complete all as specified and directed.
30S&F in repairs of Hanger door motor chain as per exisiting make complete all as specified and directed.
31S&F in repairs, power contactor 18 Amps AC3 12A/5.5 KWCE15 C series all as specified and directed.
32S&F in repairs, MCB Single pole ofcapacity0-6 Amp rated at 240-410v with 10 KA all as specified and directed.
33S& F in RepairStart/Stop Push Button of Control panel all as specified and directed
34S&F in repair Indicating LED lamp of control panel all as specified and directed.
35S&F in replacement of PVC insulated flexible copper conductor 3 core 1100 volts grade of size 4 sqmm complete all as specified and directed
36M&L for periodical inspection / servicing and cleaning ofboom barrier all as specified and directed
37S&F in replacement ofMCBSP 5- 32 Amp 240 Volts 10kA rating ISI marked complete all as spd and directed by EIC
38M & L for periodic inspection/ servicing of Dehumidefire of 175 CFM Model No : FFB-300, Bry air make all as specified and directed.
39Comprehensive maintence, testing/Servicing and repair including preventive and periodical maint with renewals and replacement of defective parts of all existing fire protection and fire fightingsystem complete consisting of main fire control panels of 1X 12.5HP Jockey pumpset, 2X 75HP electric driven pumpset, and 1X 90HP Engine driven pump, 1X 12.5HP Terrace pumps , 2X15 HP CFT pumps by necessary decarbonising ,cleaning, tightening & 100 % servicing of of all loose contact, sub panels, pressure switch, presure vessels, fire hydrents, hose reels, canvas hose pipes, gunmetal valves etc with control panel, starters and to keep Fire fighting system in auto runmode on variation in pressure to make 100% serviceability of the complete installed at ATC building of Saraswa AF station
40Comprehensive maintence, testing/Servicing and repair including preventive and periodical maint with renewals and replacement of defective parts of all existing fire alarm system complete & 100 % servicing of fire alarm panel, smoke/heat detector/response indicator, Hooters, Manual call points complete including checking, cleaning of fire detector by removing dust or dirt, cleaning of heavy greasy deposit if any, checking the connection of battaries, specific gravity of electrolyte, the alarm function control panel and indicating eqpts be checked by the operation of trigger device in each zone as described the system installed at following Bldgs of Sarsawa AF Station ATC Bldg (G+4), addressable type fire alarm system complete all as specified and as directed.
41-Ditto- as above item No. 40 but SRE Bldg (G+6), conventional type fire alarm system complete all as specified and directed
42-Ditto- as above item No. 40 but OPS Bldg (01 floor), conventional type fire alarm system NOTE for Srl No 40 & 42 (a) Cost of new components shall be paid for separately under relevant item of shchedule "A" (b) Contractor"s rep will visit once in 03 months, check and inspect every panel and on occurance of any fault during contract period take servicibility certificate duly signed by the users and MES Rep. (c) Cost of minor spares any type not costing more than Rs 500.00 per month in totaldeemed to be included in the quoted rate. (d) Payment will be processed on production of servicibilty certificate only and a panel recovery @ double the quoted rate will be charged for non carrying out of periodic serviceability check. (e)The rates quoted shall be inclusive T&P required for carrying repairs and stationery for maintaining records of periodic maintenence all as described by the Engr in charge.
43M&L for wiring in replacement with two Nos new 1100volt grade, 1.5 sqmm 2 core, FRLS, multistranded copper wire ISI marked drawn in and including PVC , 20mm, ISI Marked pipe for laying of cable fixed over the wall/roof, surface through saddles /spacers etc for making connections to fire detectors /MCP to control panels etc including taking down old unserviceable wiring with conduit pipe complete all as specified and directed.
44Taking down old unserviceablemultisensor detector any type by moveable ladder completeall as specifed and directed
45Supply and fix Addressable type multisensor detector with heat and smoke combination completeall as specifed and directed
46Supply and fix conventional type multisensor detector with heat and smoke combination completeall as specifed and directed
47Taking down old unserviceable hooter any type complete all as specifed and directed
48Supply and fix hooter conventional type complete of exisitng specification all as specifed and directed
49Supply and fix hooter addressable type complete of exisitng specification all as specifed and directed
50Supply and fix in replacementof Battary Charger 220Volt AC/12 Volt DC ,5 Amps compactpanel mounting type suitable for Fire fightingpanel for charging the battery of FF engine complete all as specified and directed by Engr in Charge.
51Supply and fix in replacement, testing and commissioning of Battary 12V, 7AH Battary complete all as specified and directed by Engr-in-charge
52Supply and fix in replacement, testing and commissioning of Battary 12V, 90AH Battary complete with battery terminals all as specified and directed by Engr-in-charge
53Supply and fix in replacementcontrol panel of 8 zone complete with charger, rectifier, 12 Volts battary, alarm display with all other neccessary attachments complete all as specified and directed by Engr in Charge.
54Supply and fix in replacement testing and commissioning of pressure switch universal type complete all as specified and directed by Engr-in- charge
55Supply and fix in replacement testing and commissioning of pressure gauge 100mm dial & 0 to 14 Kgs rating complete all as specified and directed by Engr-in- charge
56Supply & fix in replacement fire hydrant landing valve type B ( double head outlet) of 63 mm dia conforming to IS 13039-1991 along with 2 nos cost iron hand wheel , 2 nos female Instantaneous outlet, 2 nos ABS blank cap and chain complete all as specified and directed
57Supply and fix in replacement remote response indicators, complete all as specified and directed
58Supply and fix in replacement hose box wall mounting type for keeping 2 Nos hose pipe of length 15 meter each, branch pipe.nozzle, coupling etc made out of 16 gauge mild steel sheetsize 800mm x 600mm x 250mm , acrylic fronted double door with lock , 2 keys and a break glass recess for Key, painted fire red complete all as specified and as directed. Make: Padmini/DSS/Newage.
59Supply and fix in replacement branch pipe gun metal 63mm instantaneous inlet, made threaded outlet, 15mm bore nozzle long conforming to IS 903 complete all as specified and as directed. Make: Padmini/DSS/Newage.
60Supply and fix in replacement 63 mm dia 15 meter long CP hose conforming to IS 636 complete with male and female coupling conforming to IS 903. Make: Padmini/DSS/Newage.
61Supply and fix in replacement Non return butterfly valve 150mm bore complete all as specified and directed
62Supply and fix in replacement Non return butterfly valve 100mm bore complete all as specified and directed
63Supply and fix in replacement sluice valve of class PN 1.6 flanged both ends 150mm bore complete all as specified and directed
64Supply and fix in replacement sluice valve of class PN 1.6 flanged both ends 200mm bore complete all as specified and directed
65Supply and fix in replacement GI tubing 40mm dia medium grade complete all as specified and directed
66Supply and fix in replacement GI tubing 25mm dia medium grade complete all as specified and directed
67Supply and fix in replacement Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed all as specified and directed
68Supply and fix in replacement foot valve of 150mm dia conforming to IS 4038, complete all as specified and directed
69Supply and fix in replacement foot valve of 100mm dia conforming to IS 4038, complete all as specified and directed
70Supply & Fixing in replacement MCCB 200 Amps 4 Pole breaking capacity 25 KA,415 V,ICS=75 % of ICU Adjustable type with fastening elements including taking down old unsv mccb, complete all as per existing type and directed by Engr-in-charge.
71Supply & Fixing in replacement MCCB 160 Amps 4 Pole breaking capacity 16 KA,415 V,ICS=75 % of ICU Adjustable type with fastening elements including taking down old unsv mccb, complete all as per existing type and directed by Engr-in-charge.
72Supply & Fixing in replacement MCCB 63 Amps 4 Pole breaking capacity 10 KA,415 V,ICS=75 % of ICU Adjustable type with fastening elements including taking down old unsv mccb, complete all as per existing type and directed by Engr-in-charge.
73Supply and fix in replacement 3 pole power contactor CTX 150 - 150 Amp suitable for 75 HP pumpset complete all as directed.
74Supply and fix in replacement 3 pole power thermal relay RTX 150 suitable for CTX 150- 150 Ampfor 75 HP pumpset complete all as directed.
75Supply and fix in replacement 3 pole motor protection circuit breaker MPX32H - 32 Amp suitable for 20 HP pump set complete all as directed
76Supply and fix in replacement 3 pole phase failure relay VSP D2 suitable for 20 HP pump set complete all as directed. Make : Minilec
77Supply and fix in replacement DOL starter with single phase preventer suitable for 05 HP pump set complete all as specified and directed
78Supply and fixing in replacement Fire Alarm Buzzer Iductrial Electronic wind screw motor high Decibelsiren sound range upto 2 KM complete all as specified and directed.
79Comprehensive, preventive and periodical maintance of 01 No . electrically operated passenger lift of capacity 544 kg Kgs carrying 08 passengers Make : Schindler, suitable for serving G+3 floors (total 4 landings) with electric power opearted doors, auto electric levelling device completewith ARD facility installed at ATC building to be maintained roundthe clockas described here-in after in reliable, safe and efficient operating condition by regularly examine lubricating and adjust the mechanical and electrical driving equipment governer, sleeve shaft assembly bearing / contacts & governor jaws,limit switches (car & hall mechanical buttons, car & hall position indicators, car direction indicators and all other car and landing signal fixtures, deflectors, car and counter weight guide rails and buffers,equipment and carry out planned maintenance in a systematic and controlled manner using techniques and expertise consultancy includingreplacement ofspares parts as and when requiredall asdirected and specified to the entire satisfaction of Enginee-in-Charge. Note : AMC to be carried out through OEM only. MOU to this effect shall be submitted by the contractor to Engr-in-charge before starting of work.
80Supply and fix in repair Module VVVF5+ drive T2L/C2 EU/NA all as directed and specified by Engr-in-charge
81Supply and fix in repair PAPF Kit for Biodyn 12 all as directed and specified by Engr-in-charge
82Supply and fix in repair ME_PCBA SEM 21.Q version ""F"" (594239S) all as directed and specified by Engr-in-charge
83Supply and fix in repair SMI61.Q, anti-sulphur resistors all as directed and specified by Engr-in-charge
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail