Military Engineer Services-MES has published Internal Periodical Services To Md Accn And External Finishes To Certain Bldg At Bairagarh And Repair Maint Of Summer Appliances And Connected Works At Si Line Under Ge Bhopal. Submission Date for this Tender is 20-07-2022. Air Conditioner Tenders in bhopal Madhya Pradesh. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 25-Jun-2022 | Revised BOQ | BOQ | 06-07-2022 |
2 | 06-Jul-2022 | DATE | Date | 20-07-2022 |
Sl. No. | Item Description |
1 | Note :(i) Please refer Sch A/ BOQ Notes before quoting the tender for all phases/ items mentioned below. (ii) Amount of Schedule of credit shall be deducted offline Note: This work comprises of (i)INTERNAL PERIODICAL SERVICES TO MD ACCN AND EXTERNAL FINISHES TO CERTAIN BLDG AT BAIRAGARH (ii) REPAIR/ MAINT OF SUMMER APPLIANCES AND CONNECTED WORKSAT SI LINE UNDER GE BHOPAL The qty of individual part shall not vary beyond deviation limit specified in tender. |
2 | INTERNAL PERIODICAL SERVICES TO MD ACCN AND EXTERNAL FINISHES TO CERTAIN BLDG AT BAIRAGARH |
3 | Note - (i) Contractor will deposit the requisite quantity of paint (as directed by Engineer-in-charge) required for the work within 15 days from the date of commencement of the work. The paint will be issued to the contractor as and when required for carrying out the work at site which will be signed by contractor or his rep and Engineer-in-Charge. (ii) Application of oil bound distemper, exterior/interioremulsion paints, etc shall be carried out using roller brush of approved quality only. (iii) Mixing of oil bound distemper, exterior/interioremulsion paints, etc shall be carried out with mechanical mixture/strieer. (iv) Surface shall be allowed to dry completely before application of any paint. Wet or newly plastered surfaces with visible moisture shall not be painted till it is dry. (v) The rate quoted against BOQ are including neccessary scafolding etc expenses upto triple storey building. |
4 | Preparation of old decorated surfaces of wall including brooming, scraping down smoke spot, moulds, moss, efflorescent salts, trading oil, greasy spotsand stopping nails marksand M&L for applying one coat of white wash on walls completeall as specified and directed. |
5 | All as per item No-1.30 above but applying two coats of white wash complete all as specified and as directed. |
6 | All as per item No. 1.30 here-in-before but on ceiling completeall as specified and directed. |
7 | Preparation of old decorated surfaces of wall including brooming, scraping down smoke spot, moulds, moss, efflorescent salts, trading oil, greasy spotsand stopping nails marksand M&L for applying one coat of oil emulsiondistemper, white or tintedcomplete all as specified and directed. |
8 | All as per item No. 4.00 here-in-before but applying two coats of oil emulsiondistemper, white or tinted complete all as specified and directed. |
9 | M&L for applying 3mm thick wall care puttycomplete all as specified and directed. |
10 | M&L for preparing old painted surfaces of wood and wood based materials of any description over 10cm in width or girth and applying one coat of synthetic enamel paint complete all as specified and directed. |
11 | M&L for preparing old painted steel & iron surfaces of any description over 10cm in width or girth and applying one coat of synthetic enamel paint complete all as specified and directed |
12 | Preparation of old decorated surfaces of wall andapplying one coat of cement based paint, white or tinted including complete removal of existing treatment, all as specified and directed. Note:- The rate quoted areincluding neccessary scafolding expenses. |
13 | Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and as directed. |
14 | M & L for rendering 15mm thick cement plastering with CM 1:4 onbrick work or concrete surfaces including finishing the surfaces fair and even (without using extra cement) complete all as specified and as directed |
15 | M&L for preparation of newly plastered or unplastered surfaces of walls and applying two coatof cement base paintover a coat of primer complete all as specified and as directed. |
16 | M&L for preparation of existing treatment including filling of cracks, holes by suitable material like cement based putty and applying onecoat of exterior water base emulsion painton walls, parapets, chajjas, including complete removal of oldtreatment, all as specified and directed. Make : Shalimar (Saktiman)/Asian(ACE)/Burger(wall masta) or equivalent in approved make by GE. Note: The rate quoted are including neccessary scafolding expenses up to four storey buildings. |
17 | M&L for preparation of existing treatment including filling of cracks, holes by suitable material like cement based putty and applying two coats of exterior water base emulsion painton walls, parapets, chajjas, including complete removal of oldtreatment, all as specified and directed. Make : Shalimar (Saktiman)/Asian(ACE)/Burger(wall masta) or equivalent in approved make by GE. Note: The rate quoted are including neccessary scafolding expenses up to four storey buildings. |
18 | REPAIR/ MAINT OF SUMMER APPLIANCES AND CONNECTED WORKSAT SI LINE UNDER GE BHOPAL |
19 | Removing defective window/Split type air conditioner of any make and capacity from various locations and transporting to contractor workshop to carry out necessary repair as mentioned in respective item including cleaning the air conditioner with water and air pressure and to replace un-serviceable spares parts and re-fixing at various locations after repairing including testing on load at site complete all as specified and directed. (All spares compressor, fan motor, relay, capacitor, over load, shall be measured and paid separately under supply only item) |
20 | Removing unserviceable burnt sealed compressor from Air conditioner and fixing only new rotary / new sealed unit compressor of any capacity including necessary welding the same with existing refrigerant pipe, supply & charging refrigerant gas including testing complete all as specified and directed. Note:- i)Sealed unit compressor shall be measured and paid separately under supply only item) ii)If any item required to made equipment functional like cappliary,copper pipe ect is deemed to be included in coated rate. |
21 | Taking out Window/Split type Air conditioner of any make and capacity from position and cleaning the complete cooling coil & condenser coil with chemical base solution and water including servicing, oiling, greasing complete air conditioner checking of electrical connection and re-fixing the same or other location and testing complete all as specified and directed. (If any spare is required to replaced the same to be measured and paid separately under supply only item) |
22 | Supply Only following items (as per sub para 18.01 to 18 19):- Note : i)The element of fixing is deemed to be included in respective Schedule ‘A’ Items ii)If any item not consumed during the contract period the same is taken on ledger charge through Receipt Voucher if Required. iii) All replacement for failed/unserviceable compressor shall be guaranty of not less than 12 months of all such replacement.If any compressor burnt during guaranty period the same has replaced by contractor without taking any extra cost including supply & charging refrigerent gas. |
23 | New hermitically sealed / Rotary type compressor of Capcity =1.5 TR Make: Kirloskar/Carrier / Hitachi / Blue Star or eqvlt as approved by GE |
24 | New hermitically sealed / Rotary type compressor of Capcity =2.0 TR MAKE : Kirloskar/Carrier / Hitachi / Blue Star or eqvlt as approved by GE |
25 | FHP motor of capacity 1/5 to 1/18 single phase 920 RPM with starting and running capacitor suitable for window type AC. Make :As per sample or eqvlt as approved by GE |
26 | Starting capacitor 80-100 MFD/ 100-120 MFD/120-150 MFD Make: Epcos or as per recommended by manufacture or equivalent as approved by GE. |
27 | Running Capacitor 45 MFD Make : EPCOS or as per recommanded by manufacture or equivalent as approved by GE. |
28 | Running Capacitor 36 MFD Make : EPCOS or as per recommanded by manufacture or equivalent as approved by GE. |
29 | Starting relay suitable for 1.0 /1.5 /2.0 TR CompressorMake: Classic or as per sample or recommended by manufacture or equivalent as approved by GE. |
30 | Rotary/Push type selector switch suitable for 1.5/2.0 TR window type AC |
31 | Thermostat suitable for window / Split type A/C Make : INDFOSS/Godrej or as per recommanded by manufacture or equivalent as approved by GE. |
32 | Cover outer of GI Sheet heavy duty with painted for window type AC of capacity 1.5 / 2.0 TR |
33 | Front grill for window type AC of any model all as required at site and as directed by the Engr-in-Charge (Make: LG/ Lancer/ Blue star/ Carrier) |
34 | Condenser/cooling fan blade suitable for window type AC of any make & capacity |
35 | Blower fan Motor suitable for split AC of any capacity & make |
36 | Repair ofPCB for a window/split type AC of any capacity & make |
37 | Blower both end coupling complete for split AC 1.5 / 2.0 TR of any make |
38 | Cooling coil cooper tube suitable for split type AC of capacity 1.5 / 2.0 TR |
39 | Copper liquid line filter two way / One way. |
40 | Supply of Remote for Split Ac as per sample. |
41 | PVC rounded 3 core, 4.0 Sqmm copper work shop cable (approx length 2.0 m.) |
42 | Supply & replacement wiring loom complete for airconditioner with fixing complete all as specified and directed. |
43 | Supply & fix condenser/cooling coil suitable for 1.5/2.0 TR Air conditioner including refrigerant gas, gas charging and welding etc complete all as specified and directed. |
44 | M&L for rewinding of stator of FHP motor of size 1/5 to 1/18 single phase 920 RPM with super quality of copper wire of existing size complete with varnishing, backing, testing including painting with one coat of synthetic enameled black paint complete all as specified and directed. |
45 | Cutting damaged tray from window type air conditioners and replacing with existing shape and size including all necessary work such as welding, nut, bolts, drilling etc suitable for 1.5 / 2.0 TR Air conditioners complete all as specified and directed. |
46 | Charging of refrigerant gas R-32/R-22/R-410a in window / Split Type Air conditioners 1.5 / 2.0 TR at site/contractor’s workshop including all necessary work such as cost of refrigerant, welding to refrigerant pipe line, copper pipe etc and testing complete all as specified and directed. |
47 | Taking out old U/S voltage stabilizers of capacity 0.5 KVA to 5 KVAfrom MES store/site and repair the same in MES work shop (if the transformer found burnt, the in same shall be re-winded in the workshop of contractor complete all as specified and directed. |
48 | Supply Only following items (as per sub para 25.01 to 25.06):- |
49 | Main relay 24 Volts, 25 Amps. |
50 | Main Control circuit (PCB) |
51 | Output terminal 32 Amps |
52 | Replacement of Censor Transformer |
53 | Voltmeter of makes as per OEM |
54 | Time delay 2-3 minute over low voltage 180 volts AC and high voltage 260 Volt AC. |
55 | Taking out old burnt winding work and re-winded with super enameled copper winding wire (existing size) for 5 KVA voltage stabilizers including all necessary insulating material and testing complete. |
56 | All as per item No. 25.07 above but capacity of voltage stabilizer 4 KVA/3KVA. |
57 | All as per item No. 25.07 above but capacity of voltage stabilizer 2 KVA / 1KVA. |
58 | S&F sheet metal enclosure with metal clad socket and earth plug with one number MCB 20/32 Amp including connecting complete all as specified and directed. .(Make Havells / L&T/ C&S). |
59 | Transporting refrigerator of any make and capacity from MES Store Yard to contactor’s workshop for carrying out necessary repair as mentioned in respective items including back to MES Store Yard after repair and testing complete all as specified and directed. |
60 | Removing unserviceable burnt sealed compressor from refrigerator and fixing only new sealed unit compressor of any capacity including necessary welding the same with existing refrigerant pipe, supply & charging refrigerant gas including testing complete all as specified and directed. Note:- (Sealed unit compressor shall be measured and paid separately under supply only item) ii)If any item required to made equipment functional like cappliary,copper pipe ect is deemed to be included in coated rate. |
61 | Supply and install hi wall spilt units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and plasma filter for better indoor air quality with minimum 3 star rating and EER 3.2 of capacity 2.0 TR complete all as specified and directed. |
62 | Supply Only following items (as per sub para 30.01 to 30.14):- Note : i)The element of fixing is deemed to be included in respective Schedule ‘A’ Items) ii)If any item not consumed during the contract period the same is taken on ledger charge through Receipt Voucher if Required. iii) All replacement for failed/unserviceable compressor shall be guaranty of not less than 12 months of all such replacement.If any compressor burnt during guaranty period the same has replaced by contractor without taking any extra cost including supply & charging refrigerent gas. |
63 | New sealed compressor suitable for refrigerator / Deep freezer of capacity 165 Ltr/ 286 Ltr/ 310 Ltr/500 Ltr Make: Kirloskar/Whirl pool /LG / Blue star or eqvlt as approved by GE. |
64 | Relay suitable for refrigerator/Deep freezer 165/286/310 Ltr capacity Make : INDFOSS/Godrej/Whirl pool or equivalent. |
65 | Over load suitable for refrigerator/Deep freezer 286/310 Make : INDFOSS/Godrej or equivalent. |
66 | Thermostate suitable for refrigerator/Deep freezer 165/286/310 Ltr capacity Make : INDFOSS/Godrej/Whirl pool or equivalent as approved by GE. |
67 | PVC freezer door suitable for refrigerator any make & capacity. |
68 | Chiller tray of any make and capacity suitable for refrigerator. |
69 | Vegetable tray suitable for refrigirator of any make & capacity |
70 | Shelves suitable for refrigirator of any make & capacity |
71 | Magnetic rubber door gasket suitable for refrigerator of any make & capacity. |
72 | Freezer temp controlfan motor suitable for refrigirator of any make and capacity |
73 | Timer Box of suitable for Refrigirator double door of capacity200/ 310 Ltr |
74 | PVC rounded 3 core, 2.5 Sqmm copper work shop cable.Make : National / Plaza / Polycab / Gloster |
75 | Freezer Box / Chiller Assembly complete with coil and chamber of any make and capacity suitable forrefrigerator. |
76 | Fan motor suitable for deep freezer of any make and capacity |
77 | Charging of refrigerant gas R-22 in refrigerators / deep freezer any capacity at site or contractor’s workshop including all necessary work such as cost of refrigerant gas, welding to refrigerant pipe line etc and testing complete all as specified and directed. |
78 | Charging of refrigerant gas 134 in refrigerators/water cooler any capacity at site or contractor’s workshop including all necessary work such as cost of refrigerant gas, welding to refrigerant pipe line etc and testing complete all as specified and directed. |
79 | Taking down/out water cooler of any Make and capacity from various locations transporting to contractor’s workshop for carrying out repair as mentioned in respective items of Schedule ‘A’ including transporting back after repair fixing at site re-connecting electrical & water connection & its re-testing on load complete all as specified and directed. |
80 | Removing unserviceable burnt sealed unit compressor from water coolers and fixing onlysealed unit compressor of any capacity including necessary welding the same with existing refrigerant pipe, supply & charging refrigerant gas including testing complete all as specified and directed. Note:- (Sealed unit compressor shall be measured and paid separately under supply only item) ii)If any item required to made equipment functional like cappliary,copper pipe ect is deemed to be included in coated rate. |
81 | Removing un-serviceable burnt FHP motor from water cooler and supply & fixing new FHP motor with suitable fan blade single phase 1/8 to 1/35 HP suitable for up to 150 Ltr capacity water coolers including testing complete all as specified and directed. |
82 | Taking out water cooler of any make and capacity from position and cleaning the complete condenser coil & storage tank with chemical base solution and soda water including servicing, oiling of FHP motor checking of electrical & water supply connection and re-fixing the same on its original position and testing complete all as specified and directed. |
83 | Supply Only following items (as per sub para 37.01 to 37.14):- Note : i)The element of fixing is deemed to be included in respective Schedule ‘A’ Items) ii)If any item not consumed during the contract period the same is taken on ledger charge through Receipt Voucher if Required. iii) All replacement for failed/unserviceable compressor shall be guaranty of not less than 12 months of all such replacement.If any compressor burnt during guaranty period the same has replaced by contractor without taking any extra cost including supply & charging refrigerent gas. |
84 | New hermitically sealed unit compressor offor water cooler 150 Ltr Make: /Whirl pool / Kelvinator / Hitachi / Electrolux or equivelant as approved by GE. |
85 | New sealed unit compressor suitable for water cooler 40 / 80 Ltr Make: Whirl pool / kelvinator / Hitachi / Electrolux or equivalent as approved by GE. |
86 | New sealed unit compressor suitable for water cooler 60/120 Ltr Make: / Whirl pool / kelvinator / Hitachi / Electrolux or equivelant as approved by GE. |
87 | Relay & OLP suitable for water cooler of any make & capacityMake: HI-tech/Classic or as per recommanded by manufacture or equivalent as approved by GE. |
88 | Thermostat switch suitable for water cooler Make : - Indfos or as per recommanded by manufacture or equivalent as approved by GE. |
89 | Push taps along with chromium brass body suitable for water cooler capacity up to 150 Ltr (as per sample) |
90 | Fan motor blade size 12" sweep suitable for FHP motor of water cooler |
91 | PVC flexible pipe transparent 15mm/20mm dia dia (as per sample) |
92 | PVC float valve 15 / 20 mm dia with rod & ball. Make: Prayag or equivalent as approved by GE. |
93 | Running Capacitor 4 MFD Make : EPCOS or as per recommended by manufacture or equivalent as approved by GE. |
94 | 3 pin plug top one way 5 Amp, 240V Make: Great White/ Anchor / Cona |
95 | 3 pin plug top 15 Amp, 240V Make: Great White/ Anchor / Cona |
96 | Industrial type three pin metal clade socket of capacity 20 Amps 230 Volt single phase suitable for sheet metal enclouser Make:Great White/ Anchor / Cona |
97 | Industrial type three pin metal clade plug top of capacity 20 Amps 230 Volt single phase suitable for sheet metal enclouser Make:Great White/ Anchor / Cona |
98 | Charging of refrigerant gasR-22 in water cooler of any capacity at site/ contractor workshop including necessary work such as cost of refrigerant, pipe line etc and testing complete all as specified and directed. |
99 | S&F condenser coil complete with copper tube and aluminium fins for water cooler of any make and capacity as per sample complete all as specified and directed. |
100 | S&F switch socket comination 15 Amp flush type universal complete all as specified and directed. Make:Great White/ Anchor / Cona |
101 | M&L for sub main wiring with two single core 6 Sqmm (FRLS)copper conductor PVC unsheathed cable medium grade including PVC conduit (appropriate size) concealed in wall for sub main connection including 4.0 Sqmm (FRLS) PVC insulated multistranded unsheathed copper conductor used as a earth wire to common earth and connection to earth dolly complete all as specified and directed.Make:-Havells/KEI/Polycab.( Note :-Two runs of 6 sqmm (FRLS) and one run of 4.0 sqmm (FRLS) copper conductor shall be measured as one unit length.) |
102 | Taking down/out desert cooler of any make and capacity from various locations, transporting to MES Store Yard and dismantling all unserviceable parts for repair/overhauling, re-fixing the same back to its original position and making necessary connections with and including copper flexible cable 23/0.0076 Sqmm complete all as specified and directed. |
103 | M&L for replacement of wood wool pad 15mm thick made out of chicken wire mesh filled with fine quality wood wool and stitched with GI wire for desert cooler of any make & size, complete all as specified and directed. |
104 | Supply and Replacement of front grill Air Diverter of PVC with selector switch and 2 No. indicator for Desert Cooler of any make and capacity complete all as specified and directed. |
105 | S&F Fan condenser, 230 Volts of the 3.5 /4 MFD for fan motor of desertt cooler complete all as specified and directed. |
106 | M&L for rewinding of stator of exhaust fan/kit fan 18” sweep 900 RPM of any make with super quality of winding copper wire of existing size complete with varnishing, backing, testing including painting with synthetic enameled paint of gray colour complete all as specified and directed. |
107 | M&L for replacement of desert cooler’s cabinet locally fabricated with three side panels front, top and tank including vertical mention made out 22 SWG PGI sheet of size not more than 81.5 x 80.5 x 97.5 Cm with double diversion grills and grill box suitable for 18” sweep fan and making holes with fixing arrangement incl 4 way PVC distributor, PVC pipe 3 to 4 Mtr for spray water, wood wool pads, electrical wiring for fan & pump controlled separately with 5 amp Piano type switch and indicator etc complete all as specified and directed. |
108 | Supply and replacement of Submersible water lifting pump of capacity 1.25 M head, 230 Volts includingpipe complete all as specified and directed. Make: Bansal or Equivalent as approved by GE. |
109 | S&F Kit fan motor 450 mm Sweep 1350 / 1400 RPM. complete all as specified and directed.Make : Everest / Summer Cool / Khaitan |
110 | S&F desert cooler PCB of plastic desert cooler as per sample complete all as specified and directed. |
111 | S&F plastic flexible transparent pipe and nozzle for distribution of water along three sides of desertcooler complete all as specified and directed. |
112 | Supply only bottled water dispenser, having option of dispensing hot and cold water with cooling capacity 2 litrs/hr and tank capcity of 1.5 litrs, heating capacity 5 litrs/hr and tank capacity 0.8 ltrs, working in R-134a refrigerant, complete all as specified and directed. |
113 | Deduct schedule of credit (calculation will be done off line)Rs. 21320.00 |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy