Tripura Tourism Development Corporation Limited-TTDCL has published Conservation And Development Works Under Swadesh Darshan Ii Sanctioned By Ministry Of Tourism, Govt. Of India In Asi Protected Areas In Tripura At Bhubaneswari Temple, Mahadeb Bari And Pilak Site-02.. Submission Date for this Tender is 18-07-2022. Civil Work Tenders in udaipur Tripura. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description |
1 | I. BUILDING WORKS |
2 | SUB-HEAD : EARTH WORK |
3 | Surface dressing of the ground including removing vegetation and in-equalities not exceeding 15 cm deep and disposal of rubbish, lead upto 50 m and lift upto 1.5 m. |
4 | All kinds of soil |
5 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth, 1.5m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed. |
6 | All kinds of soil |
7 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. |
8 | All kinds of soil |
9 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. |
10 | All kinds of soil |
11 | Extra for additional lift of 1.5m or part thereof. |
12 | Supplying and filling in plinth, under floor, foundations etc. with sand (fine) from local quarry with all lifts including spreading in horizontal layers, watering, grading to required slope, ramming, consolidating and compacting each layer by using plate compactor or by any suitable method complete. |
13 | ANTITERMITE TRAEMENT |
14 | Supplying chemical emulsion in sealed containers including delivery as specified. |
15 | Chlorpyriphos/Lindane emulsifiable concentrate of 20% |
16 | Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment as per IS: 6313 (Part III)- Latest revision (excluding the cost of chemical emulsion): |
17 | Along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc. |
18 | With Chlorpyriphos/Lindane E.C. 20% with 1% concentration. |
19 | Treatment of soil under plinth filling using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with sand filling: |
20 | With Chlorpyriphos/Lindane E.C. 20% with 1% concentration. |
21 | SUB-HEAD : CEMENT CONCRETE WORK |
22 | Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering. All work upto plinth level: |
23 | 1:2:4 ( 1 Cement: 2 fine sand : 4 graded stone aggregate 20 mm nominal size) |
24 | 1:3:6 ( 1 Cement: 3 fine sand : 6 graded stone aggregate 20 mm nominal size) |
25 | Providing and laying cement concrete in retaining walls, return walls (any thick-ness) including attached pilasters, columns, piers, abutmets, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc. upto floor five level, excluding the cost of centring shuttering and finishing - |
26 | 1:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stone aggregate 20 mm nominal size) |
27 | Centering shuttering including struttings, propping etc. and removal of form work for: |
28 | Foundations, footings, bases for columns. |
29 | including attached pilasters, but-tresses plinth and string courses fillets etc. |
30 | Providing and laying damp-proof course with cement concrete 1:2:4 (1 cement: 2 coarse sand : 4 graded stone aggregate 12.5mm/20mm nominal size). |
31 | D.P.C. 40 mm thick |
32 | Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer"s specification |
33 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 fine sand : 6 graded well burnt brick aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth. |
34 | SUB-HEAD : Reinforced Cement Concrete Work |
35 | Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring, shuttering, finishing and reinforcement -All work upto plinth level: |
36 | 1:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stone aggregate 20 mm nominal size) |
37 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and skirting courses, fillets, columns, pillars, piers, abutments, posts and struts etc. upto floor five level excluding cost of centring, shuttering, finishing and reinforcement- |
38 | 1:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stone aggregate 20 mm nominal size) |
39 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto floor five level excluding the cost of centring, shuttering, finishing and reinforcement- |
40 | 1:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stone aggregate 20 mm nominal size) |
41 | Reinforced cement concrete work in arches, archribs, domes, vaults, shells, folded plate and roofs having slope more than 15° up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with |
42 | 1:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stone aggregate 20 mm nominal size) |
43 | Centering shuttering including struttings, propping etc. |
44 | Foundations, footings, bases for columns etc. for mass concrete with timber plank |
45 | Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc. using shuttering ply |
46 | Suspended floors, roofs, landings, balconies and access platform with timber planks |
47 | Lintels, beams, plinth beams, girders, bressumers and cantilevers with wooden plank |
48 | Columns, Pillars, Piers, Abutments, Posts and Struts with shuttering ply |
49 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. |
50 | Thermo-Mechanically Treated bars/ Cold twisted deformed steel bars |
51 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto floor five level. |
52 | Thermo-Mechanically Treated bars/ Cold twisted deformed steel bars |
53 | SUB-HEAD : BRICK WORK |
54 | First class brick work in foundation and plinth including cost of all materials as required complete. |
55 | In cement mortar 1:4 ( 1 cement : 4 fine sand ). |
56 | First class brick work in superstructure above plinth level & upto floor-five level including cost of all materials as required complete. |
57 | In cement mortar 1:6 ( 1 cement : 6 fine sand ). |
58 | Half brick masonry work with first class bricks in foundation and plinth including cost of all materials as required complete:- |
59 | In cement mortar 1:4 ( 1 cement : 4 fine sand ). |
60 | Half brick masonry with first class bricks in superstructure upto floor five level including cost of all materials as required complete:- |
61 | In cement mortar 1:4 ( 1 cement : 4 fine sand ). |
62 | Sub-Head: Marble & Granite Work |
63 | Providing and fixing gang saw cut of approved thickness mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, windows sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base of cement mortar 1:4 (1 cemebnt : 4 fine sand) with joints treated with white cement, mixed with matching pigment, epoxy touch ups, inlcuding rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels:- |
64 | 14 mm thick Rajnagar Plain white marble/ Udaipur green marble/ Zebra black marble or equivalent duly approved:- |
65 | Area of slab over 0.50 sqm. |
66 | Providing edge moulding to approved thickness marble stone counters, vanities etc. including machine polishing to edge to give high gloss finish etc. complete at all levels as required as per design approved by the Engineer-in-Charge:- |
67 | 14 mm thick Granite work. |
68 | SUB-HEAD : WOOD WORK |
69 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position : |
70 | Local Teak wood |
71 | Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veeners on both faces of shutters. |
72 | 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws. |
73 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. all complete.Fixed to steel windows by welding. |
74 | Fixed to openings /wooden frames with rawl plugs screws etc. |
75 | Providing 40 × 5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 30 × 10 × 15 cm 1:3:6 mix (1 cement : 3 fine sand : 6 graded stone aggregate 20mm nominal size) |
76 | Providing and fixing ISI marked oxidised M.S. pressed butt hinges with necessary screws etc. complete |
77 | 125 × 65 × 2.12 mm |
78 | Providing and fixing IS : 3564 marked aluminiumextruded section body tubular type universal hydraulic door closer with double speed adjustment with necessary accessories and screws etc. complete. |
79 | Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : |
80 | 300 x 16 mm |
81 | Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with necessary screws etc. complete : |
82 | 250 x 10 mm |
83 | 100x10 mm |
84 | Providing and fixing aluminium handles ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : |
85 | 125 mm |
86 | Providing and fixing aluminium hanging floor door stopper ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade with necessary screws etc. complete. |
87 | Twin rubber stopper |
88 | Providing and fixing factory made door frame (single rebate) made of solid PVC foam profile with homogenous fine cellular structure having smooth outer integral skin having 60mm width & 30mm thickness and shall be fixed to wall as per instructions of Engineer-In-Charge using 100x8 sheet metal CSK screws. |
89 | Providing and fixing 28 mm thick door shutter made of solid PVC foam profile with homogenous fine cellular structure having smooth outer integral skin having 71mm width & 28mm thick as vertical & horizontal styles. Joints are made using solventadhesive and GI ‘C sections (39mm x 19mm x 0.6mm thick) or M S pipe (40mm x 20mm ) stiffener frame insert & telescopic polymeric ‘L’ corners .The panel shall be filled with 3mm thick high - pressure compact laminate as per manufacturer’s specifications and directions of the Engineer-in-charge, cover moulding shall be provided for covering fixing screws and elegant look.( for W.C. bathroom door shutter). |
90 | Providing and fixing PVC rigid foam sheet 1mm thick on existing door shutters (bathroom and W.C. doors) using synthetic rubber based adhesive. |
91 | SUB-HEAD : STEEL WORK |
92 | Providing and fixingfan clamp type-Iof 16 mm dia M.S. bar bent to shape with hooked ends in R.C.C. slabs during laying including painting the exposed portion of loop, all as per standard design complete. |
93 | Steel work welded in built up section/framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using steel etc. complete as required:- |
94 | In stringers, treads, landing etc. of stair cases including use of chequered plate wherever required, all complete. |
95 | Providing and fixing hand rail using structural steel etc. of approved size by welding etc. to steel ladder railing, balcony railing and staircase railing etc. including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer complete as required:- |
96 | M.S. tube |
97 | Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
98 | SUB-HEAD : FLOORING |
99 | Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS : 15622 ( thickness to be specified by the manufacturer ) of approved make in all colours, shades of any size as approved by Engineer-in-charge in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1 : 3 ( 1 cement : 3 fine sand ) jointed with ordinary cement slurry including pointing with white cement mixed with pigment of matching shade complete. |
100 | Providing and laying 1st quality ceramic glazed floor tiles of approved size conforming to IS : 15622 (thickness to be specified by the manufacturer) of approved make in all colours, shades as approved by Engineer-in-charge over 20 mm thick bed of cement mortar 1 : 4 (1 cement : 4 fine sand) jointed with ordinary cement slurry including pointing with white cement mixed with pigment of matching shade complete. |
101 | Anti-Skid Tiles |
102 | Ceramic Glazed Tiles 1st quality 300 x 300mm in all shades and designs |
103 | Providing and laying polished vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08 % and conforming to IS : 15622 of approved make in all colours, shades over 20 mm thick bed of cement mortar 1 : 4 ( 1 cement : 4 fine sand ) jointed with ordinary cement slurry including pointing with white cement mixed with pigment of matching shade complete. |
104 | Double charged Stainfree vitrified tiles |
105 | Size of tile 60x60 cm |
106 | Providing and laying Vitrified tiles in different es(thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joint with white cement & matching pigments etc. complete. |
107 | Double charged Stainfree vitrified tiles |
108 | Size of tile 60x60 cm |
109 | Providing and fixing precast chequered cement concrete tiles 18 mm thick, laid in footpath & courtyard, on 20 mm thick bed ofcement mortar 1 : 4 ( 1 cement : 4 fine sand ) jointed with neat cement slurry including rubbing and cleaning complete as per direction of the Engineer- in -charge. |
110 | SUB-HEAD : ROOFING WORK |
111 | Providing and laying pressed clay tiles (as per approved pattern 20 mm nominal thickness and of approved size) on roofs jointed with cement mortar 1:4 (1 cement : 4 fine sand) mixed with 2% integral water proofing compound laid over a bed of 20 mm thick cement mortar 1:4 (1 cement : 4 fine sand) and finished neat complete |
112 | Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre,one flange fixed to the ceiling with dash fastener 12.5 mm dia x50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer"s specification and also including the cost of making openings for light fittings,grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : |
113 | 12.5 mm thick tapered edge gypsum moisture resistant board |
114 | SUB-HEAD : FINISHING WORK |
115 | 12 mm cement plaster of mix |
116 | In cement mortar 1 : 4 ( 1 cement : 4 fine sand ) |
117 | In cement mortar 1 : 6 ( 1 cement : 6 fine sand ) |
118 | 15 mm cement plaster on the rough side of single or half brick wall of mix: |
119 | In cement mortar 1 : 6 ( 1 cement : 6 fine sand ) |
120 | 6 mm cement plaster of mix: |
121 | In cement mortar 1 : 3 ( 1 cement : 3 fine sand ) |
122 | Neat cement punning. |
123 | Extra for plastering done on moulding cornices or architraves including neat finish to line and level. |
124 | In two layer |
125 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
126 | Distempering with oil bound washable distemper of approved brand and manufacture and of required shade on new work ( two or more coats ), over and including water thinnable priming coat to give an even shade. [Payment shall be made after submission of Test Certificate issued by the Manufacturer] |
127 | New work ( two or more coats) over and including water thinnable priming coat with cement primer. |
128 | Finishing walls with premium acrylic smooth exterior paint of required shade of approved brand and manufacture on new work ( two or more coats applied @ 1.43 litre/10 sqm ) over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm complete. [Payment shall be made after submission of Test Certificate issued by the Manufacturer] |
129 | New work ( two or more coats applied @ 1.43 litre/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) |
130 | Applying priming coat: [Payment shall be made after submission of Test Certificate issued by the Manufacturer] |
131 | With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel, galvanised iron / steel work. |
132 | Painting on wood work with oil type wood preservative ( two or more coats) of approved brand and manufacture on new work complete. |
133 | New work (two or more coats) |
134 | Painting with synthetic enamel paint ( two or more coats ) of required colour of approved brand and manufacture on new work to give an even shade.[Payment shall be made after submission of Test Certificate issued by the Manufacturer] |
135 | Two or more coats on new work |
136 | SUB-HEAD : ALUMINIUM WORK |
137 | Providingandfixingaluminiumworkfordoors,windows,ventilators and partitions withextrudedbuiltupstandardtubularsections/ appropriateZsectionsandothersectionsofapprovedmake conforming to IS: 733 and IS : 1285, fixing with dash fasteners of required dia and size, including necessary filling up of gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawingandthedirectionofEngineerincharge.(Glazingand paneling and dash fasteners to be paid for separately) :- |
138 | For fixed portion of approved quality:- |
139 | Anodisedaluminium(anodisedtransparentordyedto requiredshadeaccordingtoIS:1868,Minimumanodic coating of grade AC 15). |
140 | For shutters of doors, windows & ventilatorsincluding providing and fixing hinges / pivots and making provision for fixing fittings wherever required including the cost of EPDM rubber / neoprene gasket required ( Fittings shall be paid for separately ):- |
141 | Anodisedaluminium(anodisedtransparentordyedto requiredshadeaccordingtoIS:1868,Minimumanodic coating of grade AC 15). |
142 | Providing and fixing glazing of approved quality in aluminium doors,windows, ventilator, shutters and partition etc. with EPDM rubber / neoprene gasket etc. complete as per architectural drawing and the direction of Engineer-in-charge (Cost of snap beading shall be paid in basic item) :- |
143 | With float glass panes of 4.0 mm thickness ( weight not less than 10.0 kg / sqm ) |
144 | Filling the gap in between aluminium frame and adjacent RCC/brick work by providing weather silicon sealant over backer rod of approved quality etc. complete as per architectural drawing and direction of the Engineer-in charge:- (i) Upto 5 mm depth and 5 mm width. |
145 | SUB-HEAD : WATER PROOFING WORKS |
146 | Providing and laying integral cement based treatment for water proofing on horizontal surface at all depth below ground level for under ground structures as directed by Engineer-in-Charge and consisting of : (i) Ist layer of 22 mm to 25 mm thick approved and specified rough stone slab over a 25 mm thick base of cement mortar 1:3 (1 cement : 3 fine sand) mixed with water proofing compound conforming to IS:2645 in the recommended proportion over the leveling course (leveling course to be paid separately). Joints sealed and grouted with cement slurry mixed with water proofing compound. (ii) 2nd layer of 25 mm thick cement mortar 1:3 (1 cement: 3 fine sand) mixed with water proofing compound in recommended proportions. (iii) Finishing top with stone aggregate of 10 mm to 12 mm nominal size spreading @ 8 cudm/sqm thoroughly embedded in the 2nd layer.[Payment shall be made after submission of the product performance shall carry guaranteed for 10 years against any leakage] |
147 | Using rough kota stone. |
148 | Page No. 62 |
149 | 17.2 Providing and laying integral cement based treatment for water proofing on the vertical surface by fixing specified stone slab 22 mm to 25 mm thick with cement slurry mixed with water proofing compound conforming to IS:2645 in recommended proportions with a gap of 20 mm (minimum) between stone slabs and the receiving surfaces and filling the gaps with neat cement slurry mixed with water proofing compound and finishing the exterior of stone slab with cement mortar 1:3 (1 cement : 3 fine sand) 20 mm thick with neat cement punning mixed with water proofing compound in recommended proportion complete at all levels and as directed by Engineer-in-charge : [Payment shall be made after submission of the product performance shall carry guaranteed for 10 years against any leakage]. |
150 | Using rough kota stone |
151 | Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like as required as per direction of the Engineer-in-charge, consisting of : (i) 1st course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface. (ii) 2nd course of 20 mm cement plaster 1:3 (1 cement : 3 fine sand) mixed with water Proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. (iii) 3rd course of applying blown or residual bitumen applied hot at 1.7 kg. per sqm of area. (iv) 4th course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/ sqm).[Payment shall be made after submission of the product performance shall carry guaranteed for 10 years against any leakage] |
152 | Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound, as directed by Engineer-in-Charge and consisting of applying : (a) after surface preparation, first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. (b) laying second layer of Fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm. (c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/sqm mixed with water proofing cement compound @ 0.670 kg/sqm and fine sand @ 1.289 kg/sqm.This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around. (d) fourth and final layer of brick tiling with cement mortar (which will be paid for separately. [Payment shall be made after submission of the product performance shall carry guaranteed for 7 years against any leakage] For the purpose of measurement the entire treated surface will be measured. |
153 | II. PLUMBING WORKS |
154 | SUB-HEAD : SANITARY WORKS |
155 | Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushingcisternwithmanually controlleddevice(handlelever) conforming to IS : 7231, with all fittings and fixtures complete including cutting and making good the walls and floors wherever required : |
156 | White Vitreous china Orrisa pattern W.C. pan of size 580x440 mm with integral type foot rests. |
157 | Providingandfixingwhitevitreouschinapedestaltypewatercloset (European type) with seat and lid, 10 litre low level white vitreous china flushingcistern& C.P.flushbendwithfittings&C.I.brackets,40mm flush bend,overflow arrangement with specials of standard make and mosquitoproofcouplingofapprovedmunicipaldesigncomplete including painting of fittings and brackets, cutting and making good the walls and floors wherever required : |
158 | W.C. pan with ISI marked white solid plastic seat and lid |
159 | Providing and fixing G.I. inlet connection for flush pipe connecting with W.C. pan. |
160 | Providing and fixing White vitreous china flat back or wall corner type lipped front urinal basin of 430 x 260 x 350 mm and 340 x 410 x 265 mm sizes respectively |
161 | Providing and fixing white vitreous china squatting plate urinal with integral rim longitudinal flush pipe. |
162 | Providing and fixing white vitreous china wash basin including making all connections but excluding the cost of fittings: |
163 | Flat back wash basin of size 550x400mm. |
164 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. |
165 | Flexible pipe |
166 | 40 mm dia |
167 | Providing and fixing 100 mm sand cast Iron grating for gully trap. |
168 | Providing and fixing 600x450 mm bevelled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
169 | Providing and fixing 600x120x5mm glass shelf with edges round of supported on anodised aluminium angle frame with C.P. brass brackets and guard rail complete fixed with 40 mm long screws, rawl plugs etc., complete. |
170 | Providing and fixing toilet paper holder : |
171 | C.P. brass |
172 | Providing and fixing soil, waste and vent pipes: |
173 | 100 mm dia. |
174 | Sand cast iron S&S pipe as per IS: 1729. |
175 | Providing and filling the joints with spun yarn cement slurry and cement mortar 1:2 (1 cement: 2 fine sand) in S.C.I./C.I. Pipes: |
176 | 100 mm dia pipe |
177 | Providing and fixing M.S. holder-bat clamps of approved design to Sand Cast iron/ cast iron (spun) pipe embedded in and including cement concrete blocks 10x10x10cm of 1:2:4 mix (1 cement: 2 coarse sand : 4 graded stone aggregate 20mm nominal size) including cost of cutting holes and making good the walls etc. : |
178 | For 100 mm dia. Pipe |
179 | Providing and fixing heel rest sanitary bend |
180 | 100 mm dia |
181 | Sand cast iron S&S as per IS - 1729 |
182 | Providing and fixing double equal plain junction of required degree. |
183 | 100x100x100x100 mm |
184 | Sand cast iron S&S as per IS - 1729 |
185 | Providing and fixing single equal plain junction of required degree |
186 | 100x100x100 mm |
187 | Sand cast iron S&S as per IS - 1729 |
188 | Providing and fixing terminal guard: |
189 | 100 mm |
190 | Sand cast iron S&S as per IS - 1729 |
191 | Providing and fixing collar: |
192 | 100 mm |
193 | Sand cast iron S&S as per IS - 1729 |
194 | Providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes and fittings of diameter: |
195 | 100mm |
196 | Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors: |
197 | 100 mm inlet and 100 mm outlet |
198 | Sand Cast Iron S&S as per IS: 1729. |
199 | Cutting chases in brick masonry walls for following diameter sand cast iron/centrifugally cast (spun) iron pipes and making good the same with cement concrete 1:3:6 ( 1 cement : 3 coarse sand :6 graded stone aggregate 12.5 mm nominal size ) including necessary plaster and pointing in cement mortar 1:4(1cement: 4 coarse sand): |
200 | 100 mm dia. |
201 | Providing and fixing PTMT Waste Coupling for washbasin and sink, of approved quality and colour. |
202 | Waste coupling 3.1 mm of 79mm length and 62mm breadth weighing not less than 45 gms |
203 | Providing and fixing PTMT liquid soap container 109mm wide, 125mm high and 112mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colours weighing not less than 105 gms |
204 | Providing and fixing PTMT towel ring trapezoidal shape 215mm long, 200mm wide with a minimum distances of 37mm from wall face with concealed fittings arrangement of approved quality and colours weighing not less than 80 gms. |
205 | Providing and fixing PTMT 15 mm Urinal spreader size 95x69x100 mm with 1/2" BSP thread and shapes, weighing not less than 60gms. |
206 | Providing and fixing PTMT urinal cock of approved quality and colour. |
207 | 15 mm nominal bore, 80mm long. 42 mm high and 30mm wide with BSP female threads weighing not less than 48gms |
208 | SUB-HEAD : WATER SUPPLY |
209 | Providing and fixing G.I pipes complete with G.I. fittings and clamps, including making good the walls/floor etc. concealed pipe including painting two coats or more with anticorrosive bitumastic paint, cutting chases and making good the same. |
210 | Internal |
211 | 15 mm dia nominal bore |
212 | 20 mm dia nominal bore |
213 | Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. |
214 | External |
215 | 25 mm dia. nominal bore |
216 | 40 mm dia. nominal bore |
217 | Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : |
218 | 25 to 40 mm nominal bore |
219 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end): |
220 | 40 mm nominal bore |
221 | Providing and fixing ball valve (brass) of approved quality complete : |
222 | 25 mm dia. nominal bore |
223 | Providing and fixing gun metal non-return valve of approved quality (screwed end): |
224 | 40 mm nominal bore |
225 | Horizontal |
226 | Constructing masonryChamber 30x30x50 cm, inside , in brick workincement mortar1:4 (1 cement :4 fine sand) forstopcock, withC.I.surface box100x100x75mm (inside)with hingedcover fixedincement concreteslab1:2:4mix (1 cement:2 coarsesand:4gradedstoneaggregate20mmnominalsize) necessary excavation foundationconcrete 1:5:10 ( 1cement :5fine sand:10gradedstoneaggregate40mmnominalsize)andinside plastering with cement mortar 1:3 (1 cement :3 coarsesand) 12mm thick finishedwithafloatingcoatofneatcementcompleteasper standard design : |
227 | With Second Class bricks |
228 | Constructing masonry Chamber 60x60x75 cm, inside in brick work in cement mortar 1:4 (1 cement : 4 fine sand) for sluice valve, with C.I. surface box 100mm. top diameter, 160 mm bottom diameter and 190 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement :2 coarse sand : 4 graded stone aggregate 20mm nominal size ) necessary excavation foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design |
229 | With Second Class bricks |
230 | Constructing masonry Chamber 90x90x100 cm, inside with 75 class designation brick work in cement mortar 1:4 (1 cement : 4 fine sand) for sluice valve, with C.I. surface box 100 mm. top diameter, 160 mm bottom diameter and 190 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) necessary excavation foundation concrete 1:5:10 (1 cement : 5 fine sand:10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design : |
231 | With Second Class bricks |
232 | Painting G.I. pipes and fittings with synthetic enamel white paint overa ready mixed priming coat, both of approved quality for new work : |
233 | 25 mm diameter pipe. |
234 | 40 mm diameter pipe. |
235 | Painting G.I. pipes and fittings with two coats of anti-corrosive bitumastic paint of approved quality : |
236 | 25 mm diameter pipe. |
237 | 40 mm diameter pipe. |
238 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
239 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 |
240 | 15 mm nominal bore |
241 | Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms. |
242 | 15 mm nominal bore |
243 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. |
244 | 15 mm nominal bore |
245 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 |
246 | 15 mm nominal bore |
247 | Providing and fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge. |
248 | Providing and fixing PTMT pillar cock of approved quality and colour . |
249 | 15mm nominal bore, 107mm long, weighing not less than 110 grams. |
250 | Providing and fixing C.I. double acting air valve of approved quality with bolts, nuts, rubber insertions etc. complete (The tail pieces, tapers etc if required will be paid separately): |
251 | 50 mm dia |
252 | Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements weighing not less than 106 gms. |
253 | Cutting holes upto 30x30 cm in walls including making good the same : |
254 | With 1st class bricks. |
255 | Cutting holes upto 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including finishing complete so as to make it leak proof. |
256 | Making chases upto 7.5x7.5 cm in walls including making good and finishing with matching surface after housing G.I. pipe etc. |
257 | SEWAGE AND DRAINAGE WORKS |
258 | Providing, laying and jointing glazed stoneware pipes grade ‘A’ with stiff mixture of cement mortar in the of 1:1 (1 cement: 1 fine sand) including testing of joints etc. complete : |
259 | 100 mm diameter |
260 | Providing and laying cement concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) alround S.W. pipes including bed concrete as per standard design: |
261 | 100 mm diameter S.W, pipe |
262 | Supplying and fixing C.I. cover without frame for manholes : |
263 | 500 mm diameter C.I. cover (medium duty) the weight of the cover to be not less than 58 kg. |
264 | Constructing brick masonry chamber for underground C.I. inspection chamber and bends with 1st class bricks in cement mortar 1:4 (1 cement : 4 fine sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) R.C.C. top slab with 1:2:4 mix (1 cement :2 fine sand : 4 graded stone aggregate 20 mm nominal size) foundation concrete 1:5:10 (1 cement: 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement: 3 fine sand) finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design : |
265 | Inside dimensions 500x700 mm and 45 cm deep for pipe line with one or two inlets : |
266 | Extra for depth beyond 450 mm of brick masonry chamber for underground C.I. inspection chamber with same specification as mentioned in item no 20.330 complete as per standard design : |
267 | For 500x700 mm size |
268 | Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with well burnt 2nd class bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. |
269 | III. MISCELLANEOUS & MARKET RATE ITEM WORKS |
270 | Signage |
271 | Direction and Place Identification Signs more than 0.9 sqm Size Board. |
272 | Providing and erecting direction and place identification retro- reflectorised sign as per IRC :67 made of high intensity grade sheeting vide clause 801.3, fixed over luminium sheeting, 2 mm thick with area not exceeding 0.9 sqm supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M 15 grade cement concrete 450 x 450 x 600 mm, 600 mm below ground level as per approved drawing and MoRT&H Technical Specification Clause 801 |
273 | Direction and Place Identification Signs more than 0.9 sqm Size Board. |
274 | Providing and erecting direction and place identification retro- reflectorised sign as per IRC :67 made of high intensity grade sheeting vide clause 801.3, fixed over luminium sheeting, 2 mm thick with area exceeding 0.9 sqm supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm, 2 Nos. firmly fixed to the ground by means of properly designed foundation with M 15 grade cement concrete 450 x 450 x 600 mm, 600 mm below ground level as per approved drawing and MoRT&H Technical Specification Clause 801 |
275 | Providing and laying factory made kerb Stone |
276 | Providing and laying at or near ground level factory made kerb Stoneof M-25 grade cement concrete in position to the required line, level and curvature jointed with cement mortar 1:3(1cement : 3 sand), including making joints with or withoutgrooves ( thickness of joints except atsharp curve shall notmore than5 mm), including making drainage openingwherever requiredcomplete etc. as per direction of Engineer-In -Charge (length of finished kerb edgingshall be measured for payment). (Precast C.C kerb stone shall beapproved by Engineer-in- Charge). |
277 | 60mm thick factory made C.Cinterlocking paver block of M-35 Grade |
278 | Case 1- Type -A |
279 | Providing and laying 60mm thick factory made cement concrete interlockingpaver block of M-35 Grademade by block makingmachine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of sand , filling the joints with fine sand etc. all complete as per specification and approval/direction of Engineer-in-Charge. |
280 | WASTE BIN, OUT DOOR GARDEN BENCH, IRP, WATER PUMP ETC. |
281 | Supplying, providing and fixing of Out Door Garden Bench of height 27 Inch wide 25 inch and seating area of M.S hollowrectangle section (50mmx25mm) and seating pedistal of cast Iron, including primer and painting ,having seat capacity of 3 members complete in all respect. |
282 | Supplying , installation, testing & commisioning of Water pump self priming monoblock pump D series MHPB DS1X00 D1 model, pipe size 25x25 mm, head range 6-41 mtr, dischrage range 4000-800 litre/ hourhaving capacity 1HP complete in all respect. |
283 | ELECTRICAL WORKS |
284 | Wiring for light / fan / exhaust fan / call bell point with 2 x1.5 sq. mm pvc insulated copper conductor cable (FR) in pvc casing and capping complete with surface modular switch board with cover plate and modular switch including connection etc as required. |
285 | Medium Point :- |
286 | Providing and fixing of 3 pin 6/10 amps plug point withmodulartype 6/10ampsswitch andsocketincludingconnectionwith 2x1.5 sq. mm PVC insulated Copper conductor cable (FR) on surface modularswitch board, earthing the 3rd pin etc. as required. |
287 | Providing and fixing of 3/6 pin 16/20 amps plug point withmodulartype 16/20ampsswitch andsocketincludingconnectionwith 2x2.5 sq. mm PVC insulated Copper conductor cable(FR) on surface modular switch board, earthing the 3rd pin etc. as required. |
288 | Wiring for Circuit/Sub-main wiring with the following sizes PVC insulated copper conductor cable (FR) in PVC casing capping etc. as required:- |
289 | 3 X 1.5 sq mm |
290 | 3 X 4 sq mm |
291 | 3 X 6 sq mm |
292 | 3 X 10 sq mm |
293 | 3 X 16 sq mm |
294 | Supplying and fixing of the following electrical accessories including necessary connection etc. as required. |
295 | 5/6 amps piano type switch |
296 | 5/6 amps piano type 2-way switch |
297 | 16/20 amps piano type switch |
298 | 3 pin 5/6 amps piano type socket |
299 | 3/6 pin 16/20 amps piano type socket |
300 | Electronic fancy type 5 step fan regulator with cover plate |
301 | Angle/batten holder |
302 | Supplying and fixing of the following sizes GI (in recess) and plastic (on surface) modular switch boards etc. as required. |
303 | 1-2 module GI switch board:- |
304 | 3 module GI switch board:- |
305 | 4 module GI switch board:- |
306 | 6 module GI switch board:- |
307 | 8 module GI switch board:- |
308 | 12 module GI switch board:- |
309 | Supplying and fixing of the following sizes modular type cover plates for GI/plastic modular switch boards etc. as required. |
310 | 1-2 module :- |
311 | 3 module :- |
312 | 4 module :- |
313 | 6 module :- |
314 | 8 module :- |
315 | 12 module :- |
316 | Supplying and fixing of the following modular accessories including necessary connection etc. as required. |
317 | 6/10 amps one way SP switch (1M) :- |
318 | 6/10 amps one way SP switch (1M) :- |
319 | 16/20 amps one way SP switch (1M) :- |
320 | Bell push SP (1M) :- |
321 | 3 pin 6/10 amps socket outlet (2M):- |
322 | 3/6 pin 16/20 amps socket outlet (2M):- |
323 | RJ11 telephone socket outlet (1M):- |
324 | RJ45 LAN socket outlet (1M):- |
325 | TV socket outlet (1M):- |
326 | Switch board indicator lamp (1M):- |
327 | Buzzer call bell (1M):- |
328 | Blank plate (1M):- |
329 | 20/25 amps single phase motor starter switch (2M):- |
330 | Buzzer call bell (1M):- |
331 | Blank plate (1M):- |
332 | 20/25 amps single phase motor starter switch (2M)(1M):- |
333 | Earthing with 40 mm dia G.I. Earth pipe (medium gauge) 4.5 m. long complete with masonry enclosure on top CI cover plate size 12"x 12" having locking arrangement including CC work, holes on earth pipe etc. as required. |
334 | Extra for using salt (5 kg) and charcoal (46kg) for pipe earth electrode as required. |
335 | Proving and fixing / drawing of 4.06 mm dia (8 SWG) G.I. wire on surface or in existing G.I/ PVC/ Polythene pipe for loop earthing as required. |
336 | Supply and fixing of 25mm x 5mm GI strip on wall/ floor of the building for horizontal/ vertical run including necessary spacers and porcelain insulators at regular intervals. |
337 | Supplying & fixing of 1200 mm sweep white color AC ceilingfan capacitor typedouble ball bearing complete with 300 mm down rod,canopies,shackles, 3nos blades, including wiring the down rod with 2x1.5 sqmm PVC insulated copper conductor cable(FR)conformingto IS 374 (1979), BEE 5star. |
338 | Installation, testing and commissioning of ceiling fan i/c wiring the down rod of standard length (up to 30 cm) by 2 x 1.5 Sq.mm PVC insulated copper conductor cable etc as required. |
339 | Carriage of ceiling fan from store to work site. |
340 | Supplying & installation of 225/230 mm sweep metalic body exhaust fan including connection etc as required:- |
341 | Supplying & installation of 450 mm sweep 1400 rpm metalic body exhaust fan including connection etc as required:- |
342 | Supplying & installation of shutter for 230/300 mm sweep metalic body exhaust fan in the existing hole as required:- |
343 | Supplying & installation of shutter for 380/450 mm sweep metalic body exhaust fan in the existing hole as required:- |
344 | Making different sizes of hole in the wall for fixing of exhaust fan including finishing the same with cement plastering and painting etc as required: |
345 | Supplying and fixing of following surface/recess mounted LED luminaries in powder coated die cast housing complete with high efficiency polycarbonate diffuser and necessary connection etc.as required (with 50000 burning hours and minimum lumen output of 100 lm/watt):- |
346 | Surface mounted integrated 10 watt LED batten with polycarbonate diffuser:- |
347 | Surface mounted integrated 20 watt LED batten with polycarbonate diffuser:- |
348 | Recessed/Surface mounted 2ft x 2ft decorative 36 watt LED panel light with integral driver and high quality polycarbonate diffuser:- |
349 | Recessed/Surface mounted 1ft x 1ft decorative 16/18 watt LED panel light with integral driver and high quality polycarbonate diffuser:- |
350 | Surface mounted round/Square shaped 6/7 watt LED downlight with integral driver and high quality polycarbonate diffuser:- |
351 | Surface mounted round/Square shaped 12 watt LED downlight with integral driver and high quality polycarbonate diffuser:- |
352 | Supplying and fixing of following outdoor LED luminaries in powder coated die cast housing complete with heat resistant tempered glass/diffuser including necessary connection etc. as required (50000 burning hours and minimum lumen output of 100 lm/watt):- |
353 | 6 watt/10 watt LED Bulkhead light with high quality polycarbonate diffuser (IP 65):- |
354 | Supplying and fixing of following outdoor LED luminaries in powder coated die cast housing complete with heat resistant tempered glass/diffuser including necessary connection etc. as required (50000 burning hours and minimum lumen output of 100 lm/watt):- |
355 | 9 watt LED retrofit lamp with polycarbonate body and aluminium heatsink :- |
356 | 12 watt LED retrofit lamp with polycarbonate body and aluminium heatsink :- |
357 | Supplying and fixing of powder coated sheet steel enclosure on surface/recess, suitable for 240/415 volts MCB/Isolator/RCCB (SP/SPN/DP/TP/TPN/FP) complete with necessary bus bar, neutral link, din rail, earth bar etc i/c connectionas required. |
358 | 2+10 / 12 way MCB DB (double door):- |
359 | Supplying & fixing of following ratings MCBB/C curve having breaking capacity10 KA in the existing MCB DB including connectionas required:- |
360 | 6 to 32 amps SP MCB:- |
361 | 40/50/63 amps TP MCB:- |
362 | Supplying and laying of the following XLPE insulated PVC sheathed alluminum armoured cable including connection etc as required. |
363 | 3.5 core 35 Sq mm |
364 | WIRING ACCESSORIES |
365 | Supplying and fixing of the following PVC casing capping with all accessories etc. as required. |
366 | 20 x 12mm |
367 | 25 x 12mm |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy