Repair Maint Of Split Ac Window Type Ac Deep Freezer Package Type Ac And Central Type Ac Plants At 8 Fbsu Af Stn Awantipur, Awantipur-Jammu And Kashmir

Military Engineer Services-MES has published Repair Maint Of Split Ac Window Type Ac Deep Freezer Package Type Ac And Central Type Ac Plants At 8 Fbsu Af Stn Awantipur. Submission Date for this Tender is 27-07-2022. Air Conditioner Tenders in Awantipur Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

32699513
Corrigendum : Repair Maint Of Split Ac Window Type Ac Deep Freezer Package Type Ac And Central Type Ac Plants At 8 Fbsu Af Stn Awantipur
Open Tender
Indian
Jammu And Kashmir
Awantipur
27-07-2022

Tender Details

Repair Maint Of Split Ac Window Type Ac Deep Freezer Package Type Ac And Central Type Ac Plants At 8 Fbsu Af Stn Awantipur

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 29-Jun-2022 Date corrigendum Date 13-07-2022
2 08-Jul-2022 Reviseddate Date 20-07-2022
3 20-Jul-2022 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 27-07-2022

Key Value

Document Fees
INR 500 /-
EMD
INR 30000.0 /-
Tender Value
INR 15 Lakhs /-

BOQ Items

Name of Work:: REPAIR/MAINT OF SPLIT AC, WINDOW TYPE AC, DEEP FREEZER, PACKAGE TYPE AC AND CENTRAL TYPE AC PLANTS AT 8 FBSU, AF STN AWANTIPUR.
Sl. No. Item Description
1Taking down carefully Air conditioner Window type AC 1.5 ton to 2 ton and split type AC 1 ton to 2 ton opening for replacing the defective parts including disconnecting the electric connection for replacing defective parts and re-installed the same in original position and making necessary electric connection and testing complete all as specified and directed .(Labour included for fixing charges item requiredwill be measured and paid separately)
2Supply and fixing of blower fan motor in replacement suitable for cooling unit of Window type ACs of capacity 1.5/2.0 TR complete all as specified and directed.
3Supply and fixing of condensing coil as per existing make for 1.5/2.0 Ton for window AC capacity complete all as specified and directed.
4Supply and fixing of front show grill for window type AC of capacity 1.5/2.0 Ton as per existing make and modelcomplete all as specified and directed.
5Material and labour for rectification of Gas leakage (if any)and cleaning the air filter evaporator condenser complete servicing window/split type AC 1.5 TR/2 TR including charging of gas (rate for gas will be paid separately), Greasing lubrication of rotary parts and making serviceable including removing the window type AC split Type AC1.5 TR/2 TR from site & refixing in same position after repair complete with testing etc complete all as specified and directed.
6Supply and fixing of thermostat for window type AC of capacity 1.5/2 Ton, completeall as specified and directed.
7Supply and fixing of Condensing Fan Motor as per Existing Make and Capacity For 1.5/2Ton Window Type AC, complete all as specified and directed.
8Supply and fixing of outer cover in replace of broken of inner unit in replacement suitable forsplit AC any type any size complete all as specified and directed.
9Supply and fixing outer cover of outer unit in replacement suitable forsplit AC any type any size complete all as specified and directed.
10Supply and fixing of reverse valve in Split type AC to make it functional for heating also complete all as specified and directed.
11Supply and fixing capacitor capacity 4 MFD forAC.completeall as specified and directed.
12Removing the burnt blower motor window AC 1.5 TR/2 TR rewinding with super enameled copper winding wire with same gauge and superior quality with same gauge and insulation material such as varnish, cotton tape, including gun metal bush bearing shaft and refixing of original position complete with testing etc complete all as specified and directed.
13Supply and charging of gas R-22 for window AC/Split AC Completeall as specified and directed.
14Supply and fixing ofin replacement U/S compressor with new compressor capacity 1.5 Ton for window AC as per existing make complete all as specified and directed.
15All as per item No. 14 above but for 2.0 Ton capacity complete all as specified and directed.
16Supply and fixing in replacement U/S compressor with new compressor capacity 1.5 Ton for split AC as per existing make as directed.
17All as per item No. 16 above but for 2.0 Ton capacity complete all as specified and directed.
18Supply and fixing in replacement U/S compressor with new compressor capacity 1.5/2.0 Ton for invertor AC as per existing make complete all as specified and directed.
19Supply and fixing of air filter for split type AC.completeall as specified and directed.
20Supply and fixing of blower fan motor in replacement suitable for cooling unit (Outdoor unit) of split type ACs of capacity 1.5/2.0 TR complete all as specified and directed.
21Supply and fixing of Condensing Fan Motor as per existing Make and capacity for 1.5/2.0 Ton Split Type AC complete all as specified and directed.
22Removing the burnt blower motor split Ac 1.5 TR/2 TR rewinding with supper enameled copper winding wire with same gauge and superior quality with same gauge and insulation material such as varnish, cotton tape, including gun metal bush bearing shaft and refixing of original position complete with testing. (Note :- In case blower motor is not working before completion of work the contractor shall repaire with own cost).
23Supply and fixing in replacement of Fan blade SplitAC Capacity 1.5 Ton/2.0 ton complete all as specified and directed.
24Supply and fixing of capacitor as per existing make and capacity 45 MFD for compressor ofsplit/window type AC capacity 1.5/2.0 Ton, completeall as specified and directed.
25Supply and fixing of swing motor with flapper in replacement suitable for split type ACs of capacity 1.5/2.0TR complete all as specified and directed.
26Supply and fixing of condensing coil as per existing make for 1.5/2.0 Ton capacity split AC complete all as specified and directed.
27Supply and fixing of starting capacitor of 6 MFD in replacement suitable for blower motor of split type ACs of capacity 2.0 TR complete all as specified and directed.
28Supply and Fixing ofouter unit to inner unit assembly copper pipe of suitable size for split ACcompleteall as specified and directed.
29Supply and fixing of LED display in replacement of existing unserviceable LED suitable forwindow/splitAC any type any size complete all as specified and directed.
30Supply and fixing of starting capacitor as per existing make and capacity 100/120 MFD for compressor of window/split type AC capacity 1.5/2.0 Ton,completeall as specified and directed.
31Supply and fixing of air sweep louvers with motor complete set in replacementsuitable for window type ACs of capacity 1.5/2.0 TR, complete all as specified and directed.
32Supply and fixing in replacement PVC sheathed, 4 core copper conductor flexible cable of size 2.5 Sqmm with thimbles of suitable size & shape complete all as specified and directed.
33Supply and fixing of Power Circuit Board (PCB) for 1.5/2.0 TR capacity any type AC as per existing make, complete all as specified and directed.
34Renewal of gas R-410A for window AC/Split AC/ refrigerator/Deep Freezer, completeall as specified and directed.
35Material and labour for servicing of refrigerator of any make and capacity, opening the refrigerator and replacing the defective parts including disconnecting electric connection and reinstalled the same after repair/replacement and testing Completeall as specified and directed. (Labour included for fixing charges item required will be measured and paid separately).
36Supply and charging of gas R-134 A for refrigerator/ Deep Freezer, completeall as specified and directed.
37Supply and fixing of in replacement U/S compressor with newcompressor for refrigerator of capacity 1/6HP as per existing make for capacity 280/300/310 Ltrs directed.
38All as per Srl item No. 37 above but 1/8 HP for 165/180/210 Ltrs capacity complete all as specified and directed.
39Supply and fixing of compressor of 405 Ltr Voltas Deep freezer including filling up of Gas (Note: Rate for Gas shall be paid separately).
40Supply and fixing in replacement of old U/S vegetable tray for any make of refrigerator for the capacity of 280/300/310 Ltrs, complete all as specified and directed.
41Supply and fixing the new freezer door panel and gasket as per existing make and design by removing old u/s door panel and gasket from refrigerator of 280/300/310 Ltrs capacity, completeall as specified and directed.
42Supply and fixing PVC stand for refrigerator of capacity 280/300/310 Ltrs, completeall as specified and directed.
43Supply and fixing in replacement of over load/starting relaysuitable for any make of refrigerator complete with testing and commissioning for the capacity of 280/300/310 Ltrs complete all as specified and directed.
44Supply and fixing in replacement of over load/starting relaysuitable for any make of refrigerator complete with testing and commissioning for the capacity of 165/180/210 Ltrs complete all as specified and directed.
45Taking out unserviceable main PCB from voltage stabilizer andreplacement of defective parts/components by new one and making serviceable and re fixing back of the 3.0 KVA to 5.0 KVA capacity complete all as specified and directed.
46Taking out unserviceable auxiliary transformer and supply and fixing new auxiliary transformer for the 3.0 KVA to 5 KVA capacitystabilizer complete all as specified and directed.
47Taking out burnt over main transformer and rewinding the same with super enameled copper winding wire including providing proper insulating material and varnishing complete, fixing back to its original position and making necessary connections, testing complete all as directed for the 3.0 to 5.0 KVA capacity complete all as specified and directed.
48Supply and fixing in replacement of toggle switch/push button suitable for any capacity of voltage stabilizer as directed.
49Supply and Installed Voltage stabilizer wall mounted Electronic type with input & Output display, Overload & under voltage Relay ,time delay relay : single phase naturally air cooled indoor type & designed for input variation between 140 V to 260 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5.0 KVA complete all as specified and directed.
50Material and labour for Flexible water pipefor indoor unit of 2 meter length complete all as specified and directed.
51Replacement of single pole and neutral enclosure with two pin and earth plug and socket completewith one single pole MCB up to 20 amp, 240 volts complete all as specified and directed.
52Carrying out top over hauling of DG set 160 KVA including opening of upper portion of diesel engine including taking out heads, pistons, water sleeve, inlet and exhaust valve to facilate the repair work, adjustment of tappet of engine with the help of filler gauge for proper movement of valves. Assemblng of engine after carrying out overhauling work and testing the same for its firing, prevention of any leakage and testing the same to the satisfaction complete all as specified and directed.
53Supply only following parts to be fixed under above item for DG set of capacity 160 KVA. Make: crompton greaves.
54(a) Fuel filter primary. (one new will be replaced during routine maintinance due after overhauling)
55(b) Fuel filter secondary (one new will be replaced during routine maintinance due after overhauling)
56(c) Lub oil filter (one new will be replaced during routine maintinance due after overhauling)
57(d) Air cleaner filter
58(e) Hose pipe set with clamps
59(f)Flexible pipe with end connector
60(g) Fan belt for charging alternator
61(h) Fan belt for radiator
62(j)Stop solenoid actuator
63Supply and fixing in replacement Lub oil filtersuitable for capacity 160KVA DG set. Make : Kirloskar, Jyoti/Cummins.
64Supply and fixing in replacementfuel filtersuitable for capacity 160KVA DG set. Make : Kirloskar, Jyoti/Cummins.
65Supply and fixing in replacementairfiltersuitable for capacity 160 KVA DG set. Make : Kirloskar, Jyoti/Cummins.
66Supply and fixing alternator 12 V suitable for DG set 100/160 KVA including US dismantling all as directed.
67Supply and filling Coolant in radiator assembly complete all as directed.
68Supply and filling engine oil for 100/160 KVA DG set complete all as directed.
69Supply only distilled water for batteries complete all as specified and directed.
70Supply and fixing in replacement fan belt V typesuitable size for 100 to 160 KVA DG set, complete all as specified and directed.
71Supply and fixing of battery12 V, 180 AH, complete all as specified and directed.
72Material and labour for water sleeve assembly of 160KVA DG including cleaning and smoothing of bore of engine top block and testing the same for free movement of piston in the sleeve complete all as specified and directed.
73Material and labour for turbocharger repair kit of 160 KVA DG.
74Material and labour for head gasket set of160 KVA DG Set
75Routine maintenance of DG set Engine of capacity 160 KVA as per manufacturer recommendation for proper functioning of all system like fuel system, lubrication system, hoses, AVMS for wear, tightening of exuast and electric connection replacement of any parts found unserviceable. any spare required for replacement including filter, pipe, oil to be measured and separately against item"fixing only" the job does not include the works scope for any engine repairs like overhauling of engine, repair to turbo charger, radiator cleanness other major items of engine complete all as specified and directed.
76Ditto all as per item serial No-75 above but of capacity 100 KVA DG set complete all as specified and directed.
77Servicing cleaning of radiator of DG set of capacity 160 KVA by taking out the radiator from existing foundation and removal of light deposit with the use of low pressure stream jet and immersion in a healed alkali degreasent solution for 20 minutes for stubborn deposits and washing off with hot water hose and re-installation of the radiator to the satisfactory complete all as specified and directed.
78Cleaning of alternator unit of DG set of capacity 100 KVA to 160 KVA with the help of air blower to wipe dust, oil or any other unwanted liquid /solid from winding of alternator after disconnecting all electric connection and recircuit theconnection after carrying out the repairscomplete all as specified and directed.
79Supply and fixing in replacement of strip heaters 240 volts with thermostat, 3 KW, cat part no DTA (TH) Heaters 1025 Make Daspass or equivalent, complete all as specified and as directed.
80Cleaning and maintenance of cooling tower for 10/20/30 TR including replacement of defective ducting grills and repair/replacement of defective fins of by taking down of complete fins from the cooling tower and re-installing the fins on its original location after replacing the defective ones complete all as specified and directed.
81Supply and fixing plug top 20 Amp 2 pin and earth in replacement, complete all as specified and as directed.
82Supply and fixing plug socket 20 Amp 2 pin and earth in replacement, complete all as specified and as directed.
83Dismantling and rewinding of electric motor 3 phase 415 volts Capacity 2 to 5 HP with super enameled copper wire gauge as existing size and varnishing complete including replacement of ball bearing 02 Nos in each, complete all as specified and directed.
84Replacement of filter valve for 10TR AC plant cooling tower as per sample complete all as specified and directed.
85Repair to the AC plants refrigerant system by cleaning and flushing the AC pipings, cooling coil, strainers, filters & liquid line etc, by air pressure by pump and makingthe complete system leak proof by welding work (gas/electric welding as required) by renewing gasket, ‘O’ rings, taflon sheets, taflon tape etc, as required at site, carrying out the complete pressure and vacuum test (Pressure testcarried out by N2 Gas) for 24 hours, all as specified and directed for the following capacity of AC plants :- (a) 3x10 TR
86Supply and fixing heating element of capacity 6 KW 2 feetpush type suitable for 63 KWhot water Generatorcomplete all as specified and directed.
87Material and labour for descaling the entire water circulation system including condenser including mono block pump set including sealing to avoiding leakage for pump set for existing AC plants by circulating descaling solution of standard value with the help of descaling pump cleaning the condenser tubing with brush attached with rod including renewal of worn out gasket nuts and bolts etc complete all as specified for the following AC plants:-
88(i) 3 x 10 TR
89Supply and fixing stand for outdoor unit of split AC 1.5/2 TR
90Supply and fixing stand for outdoor unit of Window AC 1.5/2 TR
91Material and labour for descaling the entire Condensing coil/ condenser by descaling solution circulating solution of standard value with the help of descaling pump cleaning the condenser tubing with brush attached with rod complete all as specified for split/window ac of capacity 1.5/2 TR
92Replacement of MCB TPN 40 A rating complete all as specified.
93Replacement of MCB TPN 32 A rating complete all as specified.
94Complete servicing of central/ packaged air conditioner plant capacity 10/15/26 TR including arrangement for inspection of over all parameters of microprocessor controlled chiller water system, Hot water generator, VFD drive controller, humidity controller, Air handling unit get thoroughly checked and necessory repair/ replacement should be done and getting tested up to the satisfaction of Engr in Charge. Note:- All testing material is supposed to be included in the unit rate quoted by contractor.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy