| Sl. No. | Item Description |
| 1 | Taking down cement plaster on brick or stone walls etc. including racking out joints, hacking for key, scrubbing down with water, any description etc.including removing of rubbished material from work site complete all as specified. |
| 2 | Demolition of brick work or stone / bouldermasonry includingall quoins, arches, pillars, etc. built in cement mortar or cement lime mortar complete all as specified and directed. |
| 3 | M & L for brick work with sub class ‘B’ old size bricks, straight or curved on plan to any radius in half brick thick wall built in cement mortar 1:4 complete all as specified and directed. |
| 4 | M & L for brick work with sub class ‘B’ old size bricks straight or curved on plan exc. 6.00 m mean radius built in cement mortar 1:4 complete all as specified and directed. |
| 5 | M & L for 15 mm thick rendering in cement mortar 1:6 on fair faces of brick work or concrete surfaces and finishing the surface even and fair complete all as specified and directed. |
| 6 | M & L for 15 mm thick rendering in cement mortar 1:4 on fair faces of brick work or stone masonry surfaceswith using liquid water proofing compound and finishing the surface even and fair complete all as specified and directed. Note: WPC shall be measured and paid seperately under respective item. |
| 7 | Taking down plastering on lathing (other than wire-netting), without removing lathing, in cement or cement lime mortar (one side only measured in cases where both sides are plastered) complete all as specified and directed. |
| 8 | S&F in repair GI wire netting 0.90mm dia and 12mm mesh lathing to wood or metal studding, joists, etc. in walls, ceilings, stanchions, beams, etc. including all laps, cutting and waste patches n exc 5 sq. m each, including taking down old and jointing new to old as required complete all as specified and directed. |
| 9 | M&L for 20 (15+5) mm thick rendering on the other side of lathing plastering in cement mortar 1:4, complete framing with shuttering as one side fair and plastering with other side as fair finish form other side,complete all as specified and as directed. |
| 10 | M&L for preparing new plastered wall surfaces and apply two coats of distemper oil emulsion inclduing one coat of wall care putty on plastered surface, preparatiory to distempering onwalls surfaces, complete all as specified and as directed. |
| 11 | M&L for complete removal of existing treatment from old wall surfaces and apply two coats of distemper oil emulsion inclduing one coat of wall care putty on old surface, preparatiory to distempering onwalls surfaces,complete all as specified and as directed. |
| 12 | M&L for preparation of new plastered wall surfaces and apply two coats of acrylic emulsion paint exterior grade (APEX) camouflage painting over a coat of primer onexternal walls surfaces, complete all as specified and as directed. |
| 13 | M&L for complete removal of existing treatment from old wall surfaces and apply two coats of acrylic emulsion paint exterior grade (APEX) camouflage painting over a coat of primer onexternal walls surfaces, complete all as specified and as directed. |
| 14 | Supply only Integral water proofing compound |
| 15 | Dismantling of wall and ceiling boards (fibre, pulp, insulation, etc) or insulation boards / slabs / blankets, any thickness including cover fillets and removing from site, complete all as specified and directed. |
| 16 | S&F 12 mm thick gypsum board in ceiling fixed with screws as per manufacturer\"s instructions including two coats of oil bound distemper over a coat of primer, complete all as specified and as directed. |
| 17 | S&F aluminium anodised snap grid frame work for false ceiling size 605 x 605 mm alll as specified. |
| 18 | Dismantling of timber scantling 40 Sqcm and over in section, in any position as in Unframed work complete all as specified and directed. |
| 19 | S & F of 2nd class hard wood (SAL) in scantling, clean sawn in any position and any description as in un-framed work complete all as specified and directed. |
| 20 | Ditto all as per Item No 19here in before but except timber.(Note:- Old timber scantling reterived from Item No 18 shall be issued by the deptt for execution of this Item). |
| 21 | M & L for preparing surfaces of wood and wood based materials, new or old, of any description and girth and treated with two coats of creosote complete all as specified and directed. |
| 22 | Dismantling of boarding, any description and fixed in any position with nails complete all as specified and directed. |
| 23 | S & F of 30 mm thick 2nd class soft wood (CHIR) boarding planed one side with butt joints and fixed with nails as in flooring and skirting complete all as specified and directed. |
| 24 | Dismantling of corrugated or semi corrugated Asbestos Cement (AC) sheets in roof covering complete all as specified and directed. |
| 25 | S&F pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of colour as directed by Engineer-in-Charge having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with L-type or J-type or cranked hook bolts in lieu of self tapping screws, complete all as specified and directed. |
| 26 | S&F pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of camouflage colour having tensile strength of 550 Mpa as in ridges fixed with L-type or J-type or cranked hook bolts in lieu of self tapping screws, complete all as specified and directed. |
| 27 | S&F mild steel work in hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts, complete all as specified and directed. |
| 28 | Demolition of cement concrete (un-reinforced) in ground floor and paving not exc. 15 cm thick (Below and above ground level) complete all as specified and directed. |
| 29 | M & L for providing 25 mm thick cement concrete 1:2:4 type B0 Nominal Mix (using 12.50 mm thick graded stone aggregate) as in floor, laid in panels and position to conform to design and finishing top surface even and smooth with using extra cement complete all as |
| 30 | M&L for Non-skid coloured ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15 mm thick screeding in CM 1:6 complete all as specified and directed.(Note:- Quoted rates deemed to be include for 15 mm screed bed). |
| 31 | M&L for vitrified ceramic tiles light shade 10 mm thick (square/rectangular) polished, area of each tile exceeding 0.36 sqm in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15 mm thick screeding in CM 1:6, complete all as specified and directed.(Note:- Quoted rates deemed to be include for 15 mm screed bed). |
| 32 | M&L for coloured glazed ceramic tiles 450x350x7 mm thick, on vertical surfaces such as skirting, dados and risers to stepsetc, set and jointed in neat cement slurry and pointed in white or coloured cement to match over 10mm thick rendering in CM 1:4 on brick wall, complete all as specified and directed.(Note:- Quoted rates deemed to be include for 10 mm thick rendering). |
| 33 | M&L for 75 mm thick cement concrete 1:3:6, type C1 using 40 mm graded stone aggregate as in sub base of flooring/ hard standing and plinth protection etc laid in alternate pannel, surfaces finished even and smooth with using extra cement, complete all as specified and directed. |
| 34 | Taking down or up 15 mm bore steel tubing and connections, including cleaning for re-fixing or remove to store complete all as specified and directed. |
| 35 | Ditto all as per Item No 34 here in before but 20mm bore steel tubing. |
| 36 | S & F 15 mm bore galvanised steel water tubing medium gradewith and including all fittings and fixed to wall or laid in trenches complete all as specified and directed. |
| 37 | Ditto all as per Item No 36 here in before but 20mm bore steel tubing. |
| 38 | S&F in repairs 15 mm bore Bib taps, chromium plated fancy type, screwed down, screwed for iron pipe or for brass ferrule, complete all as spcified and as directed. |
| 39 | S & F in repairs 15 mm bore Stop valves, chromium plated fancy type screwed both ends for iron pipe or for unions, complete all as spcified and as directed. |
| 40 | S & F in repairs 15 mm bore pillar taps, Cast Copper alloy, with capstan heads, chromium plated, screwed down high pressure with or without lettered Hot or Cold with long screwed shanks and fly nuts, screwed for iron pipe, complete all as spcified and as directed. |
| 41 | S & F in repairs vitreous China wash basin, angle back, size 550x400mm white,including waste coupling and waste pipe excluding taps, waste, chain and plug and porcelain stopper but including brackets, complete all as spcified and as directed. |
| 42 | S&F in repairs 10 Litres, PVC, valve less, syphonic action type, flushing cistern, high level, white inlet, ball valve, float, chain and pull, and brackets including PTMT PVC connection 600mm long, complete all as spcified and as directed. |
| 43 | S&F in repairs vitreous china wash down water closet pedestal pattern white excluding flush pipe flushing cistern etc but including connection to drain pipe and to flushing pipe etc, complete all as spcified and as directed. |
| 44 | M&L for RCC NP3 150 mm diameter pipes in repairs laid on 150 mm thick PCC 1:4:8 type D2 using 40mm aggregate bed, complete with excavation in any type of soil, including minor repairs of manholes/drop manholes of standard size made of Brick masonry/ RCC/Precast RCC with SFRC ventilating cover and frame Including all items and activities required at site to make sewer line functional avg depth 1.5 Mtr, complete all as spcified and as directed. |
| 45 | M&L for600mm x 450 mm bevelled edge mirror of selected quality glass, mounted on 6 mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers, complete all as spcified and as directed. |
| 46 | S & F in repairs Ball 20mm brass valves, high pressure, with polythene float and fly nut complete, screwed for iron pipe or brass ferrule and fixed, complete all as spcified and as directed. |
| 47 | S&F 500 litres capacity rotational moulded polyethylene water storage tanks (Cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I including disconnectiong of existing tank and removing from site to store complete all as spcified and as directed. |
| 48 | S & F in repair Brass chromium plated tubular towel rail, 20mm dia, D type, 60cm long between flange allas specified and diracted. |
| 49 | S & F in repair for Toilet paper holder of vitreous china (White) fixed to walls with chromium plated (CP) brass screws complete all as specified and directed. |
| 50 | S & F in repair for Vitreous China bowl type urinals, size of 465x355x265mm white (minimum) with greating and union for discharge pipe complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe. (excluding of fixing supply pipe, flushing cistern, flush pipe, trap and waste pipe) complete all as specified and directed. |
| 51 | S & F450 mm long PVC connection with two Nos. PTMT nuts internally threaded and PVC washer suitable for 15 mm bore pipe line complete all as specified and directed. |
| 52 | S&F Salt-glazed Stoneware gully traps of size 150 X 150mm, square or round mouthed, type \"P\"complete all as spcified and as directed. |
| 53 | S&F PVC (SWR) floor trap of 75 mm dia of oulet pipe, plain with grating including jointing with solvent cement,complete all as spcified and as directed. |
| 54 | S&F Urinal spreader of PTMT any colour for fixing with 15 mm dia pipe (Minimum weight 60gms) complete all as spcified and as directed. |
| 55 | Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories) complete all as spcified and as directed. |
| 56 | S & F 110 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints fixed to walls,complete all as spcified and as directed. |
| 57 | Ditto all as per Item No 56 here in before but 75mm bore. |
| 58 | S & F 110 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring jointslaid in floor or trenches,complete all as spcified and as directed. |
| 59 | Ditto all as per Item No 58here in before but 75mm bore. |
| 60 | S & F PVC (SWR) 110mm bore bend of any radious complete all as spcified and as directed. |
| 61 | Ditto all as per Item No 60 here in before but 75mm bore. |
| 62 | S & F PVC (SWR) 110mm bore bend of any radious with access door complete all as spcified and as directed. |
| 63 | Ditto all as per Item No 62 here in before but 75mm bore. |
| 64 | S&F PVC (SWR) 110mm borejunction single, (Single T) equal or unequal,complete all as spcified and as directed. |
| 65 | Ditto all as per Item No 64 here in before but 75mm bore. |
| 66 | Taking down chowkhats or frames area exc. 1.50 Sqm but not exc. 4.00 Sqm each with shutters (without taking off shutters from the frames) complete all as specified and directed. |
| 67 | M&L for Solid PVC Double door frame of size 50mmx 95mm made out of 5mm Plain colour PVC sheet reinforced with M.S. tube, suppling &fixing in opening as per specification & drawing complete all as specified and directed. |
| 68 | M&L for factory made solid PVC moulded door shutter with particle board core, 28 to 30 mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick moulded PVC Sheet on the front face & 2 mm plain colour PVC sheet on back face, supplying & fixing in frame at site as per direction of Engineer-in-Charge. |
| 69 | S&F anodised aluminium powder coated (thickness or powder coating not less than 50 micron) window and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodized aluminium snap beading, screws etc. complete all as specified and directed. |
| 70 | S&F 5.5 mm thick sheet glass ordinary quality and glazing with oil putty / wooden beads in square n.exc 0.50 sqm in each pane complete all as specified and directed. |
| 71 | S&Fsolid PVC door frame of size 50 mm x 47 mm made out of 5 mm thick plain colour PVC sheet reinforced with MS square tube as per specification and drawing (SSR - 2020 Part-II Rates) complete all as specified and directed. |
| 72 | S&F factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes fortop rails, bottom rails stiles & lock rail. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement as per specification complete all as specified and directed. |
| 73 | Taking down roof trusses above 4 metres & upto 8 metres, coupled raftersor trussed beams but including taking down trusses etc., for renewal of any defective members (timber renewed to be measured separately) and reassembling complete all as specified and directed. |
| 74 | M&L for Housing and fixing trusses above 4 metres & upto 8 metres etc. after repairs including tightening up wedges, cotters bolts etc. complete all as specified and as directed. |
| 75 | M&L second class hard wood in scantlings in framed work if in repairs, to replace old and decayed timber (including piecing, scarfing, etc., of old and new timbers if required) and removing defective portions to storecomplete all as specified and directed . |
| 76 | Dismantling of structural steel work including doors, gates but excluding framed trusses complete all as specified and directed. |
| 77 | M&L rolled mild steel conforming to Fe 290 (Gde E-165), in rooftrusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel orflatsections) and including distance pieces, cleats etc. complete all as specified and directed. |
| 78 | M & L for preparation of New or previously un-treated steel surfaces over 10 cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed. |
| 79 | M & L for preparation of New or previously untreated wooden surfaces exc. 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed. |
| 80 | M & L for preparation of Old painted wooden surfaces exc. 10 cm width or girth and applying one coats of synthetic enamel paint complete all as specified and directed. |
| 81 | M & L for butt hinges of sizes 100mm, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type B-21 complete all as specified and directed. |
| 82 | Ditto all as per Item No 81 here in before but 125mm sizes. |
| 83 | S&F 150 mm Aluminium handles cast type, anodisedand fixed complete all as specified and directed. complete all as specified and directed. |
| 84 | Ditto all as per Item No 83 here in before but 200mm long. |
| 85 | S&F 150 mm long aluminium, anodised, barrel tower bolt of extruded section and fixed complete all as specified and directed. |
| 86 | Ditto all as per Item No 85 here in before but 200mm long. |
| 87 | S&F in repair 300 mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and directed. |
| 88 | S & F in repair of Door closer aluminium (extruded body) Hydraulically regulated ( designation No. 3) universal type, suitable for door shutters of 851 to 1000 mm in width and weight between 61 t0 80 kg complete all as specified and directed. |
| 89 | M&L for PCC 1:3:6 type C-2 (using 40 mm graded crushed stone aggregate) as in surface channel and drain complete all as specified and directed. |
| 90 | Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred / stopped ends etc.complete all as specified and directed. |
| 91 | S&F galvanised mild steel wire cloth 0.56 mm nominal dia of wire and average width of aperture 1.18 mm and fixed with tinned tacks or galvanised wire staples and including wooden beads complete all as specified and directed. |
| 92 | S&F 3 mm thick sheet glass ordinary quality and glazing with oil putty / wooden beads in square n.exc 0.50 sqm in each pane including hacking out old broken glass (any thickness, size, quality or description) from wooden frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads complete all as specified and directed. |
| 93 | S&F drapery rod 25mm dia with PVC pipe over MS conduit including curtain rings suitable for 25mm dia pipe appx 08 Nos per RM & brackets etc. complete approved colour and quality as directed by Engineer-in-charge. |
| 94 | E/M PORTION:-Taking down copper / aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting , casing caping etc., removing materials to store for keeping in safe custody or for taking credit, cutting chasing as required and making good the disturbed surfaces including finishes to match with adjacent surfaces of walls, floors, etc. complete all as specified and as directed. |
| 95 | M&L point wiring with 1.5 sqmm single core, PVC insulated, unsheathed FRLS copper cable, 1100 volts grade, with multi stranded copper conductor drawn through and including PVC casing caping (double lock pattern) medium grade and accessories on wall / ceiling surfaces etc. with and including 1.5 sqmm single core PVC insulated, multistranded, unsheathed,FRLS copper conductor cable as continuous earth continuity conductor (green in colour) with cast Iron / pressed steel terminal boxes 60 mm deep, on walls with 3 mm thick plastic laminated / hylam sheet cover, fixed on wall / other surfaces with brass screws for mounting or housing switches, socket outlets, fan regulators, etc including all other fixing accessories for one light / fan / bell point controlled by one 5 / 6 Amps switch complete all as specified and directed. |
| 96 | All as per Sl. item No. 95above but for one 5 / 6 Amps socket outlet point on independent board. |
| 97 | M&L point wiring with 2.5 sqmm single core, PVC insulated, unsheathed FRLS copper cable, 1100 volts grade, with multi stranded copper conductor drawn through and including PVC casing caping (double lock pattern) medium grade and accessories on wall / ceiling surfaces etc. with and including 1.5 sqmm single core PVC insulated, multistranded, unsheathed,FRLS copper conductor cable as continuous earth continuity conductor (green in colour) with cast Iron / pressed steel terminal boxes 60 mm deep, on walls with 3 mm thick plastic laminated / hylam sheet cover, fixed on wall / other surfaces with brass screws for 15 / 16 Amps socket outlet on independent board complete all as specified and directed. |
| 98 | S&Fswitch pianoflush typeone way, 5 / 6 Amps, 230 voltcomplete all as specified and directed. |
| 99 | S&F switch socket combination 2 in 1, 5 pin, 5 / 6 Amp, piano flush type complete all as specified and directed. |
| 100 | S&F switch socket combination2 in 1,6 Pin, 15/16 Amp, piano flush type universal complete all as specified and directed. |
| 101 | S&F stepped type electronic fan regulator, piano flush typewith 5 step, AC 50 Hz 230 Volts grade complete all as specified and directed. |
| 102 | Supply and fixing ceiling rose (ISI marked) surface bakelite 65 mm x 50 mmthree terminal suitable for 230 Volts AC 6 Amps complete all as specified and directed by Engineer-in-charge. |
| 103 | Taking downcopper / aluminium concealed sub main wiringcomplete with all fixture and fittings including cutting chasing as required and making good the disturbed surfaces including finishes to match with adjacent surfaces of walls, floors, etc. complete all as specified and as directed. |
| 104 | M & L for sub main wiring with 2 runs of 4.0 sqmm main wire alongwith 1 run of 4.0 sqmm earth wire (green in colour) single core FRLS PVC insulated, unsheathed, multi-stranded, 1100 volts grade copper conductor cable, drawn through and including adequate size PVCcasing caping (double lock pattern) medium grade with all fittings & accessories on walls / ceiling surfaces etc., complete all as specified and directed.NOTE :- Two runs of main copper conductor, one run of earth wire and one run of PVC casing caping shall be measured as one unit length. |
| 105 | All as per item No. 104 above but with 2 runs of 6 sqmm main wire along with 1 run of 6 sqmm earth wire. |
| 106 | Taking down old unserviceable light fitting of any size/type from any situation complete all as specified and as directed by Engineer-in-Charge. |
| 107 | S&F round shape 15 watt, 230 volts, 50 Hz, down lighter, recessed type with high efficiency diffuser soft glare free light complete with driver, holder, LED lamp suitable for roof ceiling including connecting up with flexible copper conductor cable of suitable size complete all as specified and directed. Make: CROMPTON GREAVES cat part no. LSCRM-15W-CDL/PHILIPS cat no. SM251C LED16S-6500 PSU WH or equivalent ofGE. |
| 108 | S&F LED light fitting 1x20 watts ,230 volts, 50 Hz decorative box type with driver, holder including LED tube light connecting up with flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. Make: CROMPTON GREAVES cat part no. LDL-20-CDL/PHILIPS cat no. BN021C LED20S PSU CW GR S2 or equivalent ofGE. |
| 109 | S&F ultra slim LED batten 1x10 watts ,230 volts, 50 Hz decorative LED lighting fixturewith extruded polycarbonate, environment friendly including lamp, holder connecting up with flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. Make: CROMPTON GREAVES cat part no. LDL-10CDL/PHILIPS cat no. BN021 LED10S-6500 PSU GR S1 or equivalent ofGE. |
| 110 | Taking down old unserviceable Celling fan of any capacity, dismantling the blades, rod, frame complete shifting and stocking at MES store yard within five KM radius complete all as specified and directed by the Engr-in-Charge. |
| 111 | Taking down and refixing after complete repairing of the ceiling fan of any make/model/sweep in its original position, connecting and testing, including provision of cable from ceiling rose/connector to fan , ball bearing, capacitor, gun metal bush, split pin, etc. complete all as specified and as directed by concern Engineer-in-charge. |
| 112 | Taking down and refixing after complete repairing of the exhaust fan 300mm sweep of any make/model/sweep in its original position, connecting and testing, including provision of cable from ceiling rose/connector to fan , ball bearing, capacitor, gun metal bush, split pin, etc. complete all as specified and as directed by concern Engineer-in-charge. |
| 113 | Taking down old MCB of any description/size from any position etc.complete all as specified and as directed by concern Engineer-in-charge. |
| 114 | Supply, testing & hanging of energy saving non-decorative ceiling fan 230 volts, single phase AC, 1200 mm sweep, BEE 5 star rated, Brushless Direct Current (BLDC) without remote type complete with piano type electronic fan regulator and accessories like holding down rod, hanging clamps, blades including writing MES number (as per standard practice) & flexible three core copper conductor cable of suitable size for connecting with ceiling rose complete all as specified and directed by the Engineer-in-Charge.Note:Contractor will provide guarantee of ceiling fan against any type of defect for a period of minimum two years from the date of completion of work and rate for same is deemed to be included in the item quoted rate. |
| 115 | Supply and Fixing in repair PVC insulated, PVC round sheathed, copper conductor cable 2.5 Sqmm three core for connection of street light/ flood light/ post top lantern etc on pole /wall/ pillar from junction box including termination clip etc complete all as specified and directed by Engineer-in-charge. |
| 116 | Material and labour for disconnecting unservicable under ground LT cable of any size/type from existing pole or building or any location including removing of dismentalled material from work site complete all as specified and as directed by Engineer-in-Charge. |
| 117 | Supply and Laying LT under ground XLPE cable of size 16 sqmm, 4 core including testing and commissioning insulated, screened, PVC bedded, armoured steel strip or wire armoured,electric cable (heavy duty) with multistranded aluminium conductor,1100 Volts grade in trenches/on wall/poles laid in ducts/inside protection pipe including cable glands,lugs and suitable size of MS saddle clips (where ever cable laid in ceilings / walls without cable duct) complete all as specified and as directed by Engineer-in-Charge.Note:- Excavation,sand cushioning,brick will be measured and paid separtely. |
| 118 | Ditto all as per Item No 117here in before but 25 sqmm 3.5 core cable. |
| 119 | Excavation in trenches not exc 1.5 mtr wide and not exc 1.5 mtr in depth; for trench of cable etc and getting out in Soft/loose soil including making good the disturbed surface such as hardstanding, footpath and pavements etc. complete all as specified and as directed by Engineer-in-Charge. |
| 120 | Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm in Soft/loose soil complete all as specified and as directed by Engineer-in-Charge. |
| 121 | Removing excavated material to a distance n.exc 50 mtr and depositing where directed at level n.exc 1.5 mtr above the starting point complete all as specified and as directed by Engineer-in-Charge. |
| 122 | Supply and Laying sand coarse dry as in cushioning of underground electric cable in trenches, laid to a uniform thickness of 23 cm (15cm under the cable & 8cm over the cable) and gently punned down to 18 cm thickness all complete all as specified and as directed by Engr-in-Charge.Note: Only punned down sand shall be measured. |
| 123 | Material and labour for well burnt bricks having crushing strength 75 kg/sqcm best quality locally available laid flat, dry in trenches for cable protection complete all as specified and as directed by Engr-in-Charge. |
| 124 | Supply & fixing in repair loop in loop out polycarbonate Junction box in accordance with IEC 60670-22of size 200 mm x 160 mm x 98 mm, suitable for LT cable 25 sqmmwith front openable hinged cover and locking arrangements with IP 66 degree of protection, with MCB \"C\" series,10 Amps, Single Pole, 10 KA, 240 volts and aluminium bus bar of suitable capacity complete with electrical connection fixed to pole/wall with suitable size FI clamp 20mm x 3mm, nuts, bolts and washer including duty painted with powder coated paint complete all as specified and directed by Engineer-in-charge. |
| 125 | S&F in repairs MCB SP 10 to 32 Amp, 10 kA, 230V\"C\" curve complete all as specified and as directed. |
| 126 | S&F in repairs MCB TPN 63 Amp, 10 kA, 230V\"C\" curve complete all as specified and as directed. |
| 127 | S&F in repairs MCB SPN 16 to 32 Amp, 10 kA, 240V\"C\" curve complete all as specified and as directed. |
| 128 | Taking down old sheet metal enclosure/MCB DB of any description/size from any position etc.complete all as specified and as directed by concern Engineer-in-charge. |
| 129 | Supply and fixed in repairs connection and testing AC Plug and socket DB, 20Amp, 230 volts, 50Hz with one No.MCB SP 230 Volts, \"C\" series, breaking capacity 10 KA of rating 20 Amps complete all as specified and directed |
| 130 | S&F in repair MCB DB, SPN 12 way, 230 volts, 50Hz, IP-43, IK 09, double door type with metal door, with 100A copper neutral and earth bus bar for fixing MCB, fixing flush to wall & making good the disturbed surfaces complete all as specified and as directed. |
| 131 | S&F in repair MCB DB, TPN 4 way,415 volts, 50Hz, IP-43, IK 09, double door type with metal door, with 100A copper neutral and earth bus bar for fixing MCB, fixing flush to wall & making good the disturbed surfaces complete all as specified and as directed. |
| 132 | M&L earthing complete with galvanised steel earth plate electrode of size 600 x 600 x 6 mm thick buried directly in ground in vertical position (earth pit not less than 2.25 m deep below the normal ground level) with top edge of the earth plate not less than 1.5 m below normal ground level, connected to earth lead of galvanised iron strip 32 x 6 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel, all as shown in electrical plate No. 3 connected to earthing test point including dismantling complete all as specified and directed.Note:- The unit rate shall also include for earth work in any type of soil, PCC 1:3:6 type C1 chamber, RCC 1:1.5:3, type A1 cover slab, 50 mm thick reinforced with 8 mm dia TMT bar @ 140 mm C/C both ways, 10 mm dia plain bar lifting handle embedded in cover slab, 20 mm bore medium grade GI watering pipe, 40 mm bore GI light grade earth lead protection pipe, funnel, wire mesh, copper lugs, charcoal and common salt in alternate layer etc. |
| 133 | Supply and fixing Galvanised iron strip 32 x 6mm with fixing screws for conductors/ earth lead including welding and nut bolts jointing at all joints for building/ equipment laid through pipe/trench/surface buried in ground complete all as specified and directed |
| 134 | S&F 40 mm bore galvanised steel tubing, light grade with necessary fittings, fixed along electric pole/ treches/ roof /floor /wall etc, for cable earth strip /cable protection etc. complete all as specified and directed. |
| 135 | Taking down old unserviceable service connection complete with connected items of any description/ size from any indicated situation complete all as specified and as directed. |
| 136 | Material and labour laying well burnt old sizebricks, straight or curved on plan , laid flat with width equal to length of brick , laid dry over electric cable for protection all as specified. |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-2 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-3 Issued
Clarifications on tender conditions and amendments issued.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender