Repair Replacement Maintenance Of Unserviceable Security Lights Alongwith Connect Itmes At Af Stn Bhisiana As Per Boq / Price Schedule
Tender Overview
Project Description
Repair Replacement Maintenance Of Unserviceable Security Lights Alongwith Connect Itmes At Af Stn Bhisiana As Per Boq / Price Schedule
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 08-Jul-2022 | Amendment to Critical date | Date | 25-Jul-2022 |
| 2 | 25-Jul-2022 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 01-Aug-2022 |
BOQ
| Sl. No. | Item Description |
| 1 | Disconnecting & Taking down/out unserviceable LT Cable of any size and any description from Trenches, Floors, Walls, GI Pipes, etc. incuding Serviceable Pipes, Bricks, etc. and depositing to MES store yard for reusecomplete all as specified and as directed.NOTE : Necessary Earth Work will be Measured and Paid under appropriate Items. |
| 2 | Supply & Laying/ Fixing ofXLPE insulated, screened armoured heavy duty Electric Cable with Aluminium Conductor Multi Stranded, 1100 Volt grade, Cross sectional area 25 Sqmm 4 Core including necessary Aluminium Thimbles, jointing and Testing, complete all as specified and as directed. |
| 3 | Supply & Laying/ Fixing ofXLPE insulated, screened armoured heavy duty Electric Cable with Aluminium Conductor Multi Stranded, 1100 Volt grade, Cross sectional area 16 Sqmm 4 Core including necessary Aluminium Thimbles, jointing and Testing, complete all as specified and as directed. |
| 4 | Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated copper conductor served with an inner sheathing of PVC tape with galvanised steel wire or tape and overall PVC sheathed2 core 2.5 sq. mm nominal cross section in service connections. |
| 5 | Excavation in Trenches not exc. 1.50 Metre wide and not exc. 1.50 Metre in depth for laying of UG Cable/Pole/Stays, etc., getting out including forming bottom surface to required level and gradient in Soft/ Loose Soil and getting out, complete all as specified and as directed. |
| 6 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 Cm in Soft/ Loose Soil, complete all as specified and as directed. |
| 7 | Removing excavated materials not exc. 50.00 Metre and depositing where directed at a level not exc. 1.50 Metre above the starting point, complete all as specified and as directed. |
| 8 | M&L Sand (Fazilka) Cushioning (dry) in Trenches/Ducts for protection of UG Cables (below, above and around the UG Cable laid) of 23 Cm Spread thickness (8 Cm in depth before laying the Cable and 15 Cm in depth after laying the Cable) and consolidated (punned) upto 180mm thickness, complete all as specified and as directed.NOTE : For the purpose of Payment, punned thickness of Sand Cushioning only will be Measured. |
| 9 | Supply & Laying old bricks to provide brick protection cover of UG cable by old size bricks common burnt clay building bricks sub class `B’ laid dry and flat abutting each other with width equal to length of brick and gap between adjacent brick not exceeding 10 mm complete all as specified and directed. |
| 10 | Material and labour for preparation of old painted steel pole surfaces and applying alternatively in yellow and black one coat of synthetic enamel black paint to steel tubular pole upto 1 mtrheight from ground level and remaining with two coatsaluminium paint to LT poleincluding numbering of pole with black paintcomplete as specified and directed by Engr-in-Charge. |
| 11 | Material and labour for preparation of old painted PCC pole surfaces and applying alternatively in yellow and black one coat of synthetic enamel black paint to PCC pole upto 1 mtrheight from ground levelto LT pole including numbering of pole with black paintcomplete as specified and directed by Engr-in-Charge. |
| 12 | Supply, installing, testing and commissioning factory madeLT feeder pillar box Outdoor type platform mounted, suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system all as specified and directed having bus bar installed on DMC/Epoxy insulators. The panel shall be dust and vermin proof, IP-65 class protection and made of 3.15 mm CRCA MS sheet with frontopeningtype with double door shutter and locking arrangement (including provn oflock with 2 keys), powder coated finish (over a coat of red oxide), primer on outside and two coats of red oxide primer on inside surfacewith TPN aluminium bus bar of rating not less than 200Amps including 1 No MCB SPN 06 Amps on suitable foundation of concrete surface, complete all as directed by Engineer in Charge. |
| 13 | Supply and fix Pole Mounted Junction Box having aluminium bus bar suitable for street light connections including single pole MCB of rating 6 Amps, 2.5 sqmm copper comductor for connection and fixing arrangement to pole all as specified and directed by Engineer-in charge |
| 14 | S&F Tubular swaged poleincluding taking down for steel tubular swaged poleswith welded brackets type 410-SP-31 (09 mtr long) with mild steel base plate of size 30cmx30cmx6mm thick, welded at bottom including taper plugs, bolt, nuts and screw as directed and fixed in true vertical position complete all as directed by Engineer in Charge.Note :- (a) Earth work, shall be measured and paid separately under respective items.(b) Poles shall be painted with two coats of black bituminous paint throughout internally and externally up to foundation depth and Exterior surface shall be painted with two coats of aluminium paint over a coat of red oxide primer(c) Cement Concrete 1:3:6 Type C-1 (20mm graded stone aggregate)and necessary form work ofrequired depth shall be measured and paid seperately under appropriate items. |
| 15 | M&L Galvanised Steel Tubing Pipe 15mm bore (dia), Medium grade with Bend, laid in Trenches or under Roads/ Flooring/ Culverts and/or fixing to Electric Poles with suitable size Mild Steel Flat Iron Clamps, Bolts, Nuts, Washers, etc., complete all as specified and as directed. |
| 16 | M&L Cement Concrete 1:3:6 Type C-2 (40mm graded stone aggregate) as in Foundation of Electric Poles/ Strut/ Stay, etc. including weathering slightly rounded or chamfered angle and throating, finishing all exposed faces of Concrete with necessary Formwork including dismantling existing concrete work, complete all as specified and as directed. |
| 17 | M&L Cement Concrete 1:3:6 Type C-1 (20mm graded stone aggregate) as in Pole Pedestal, etc. including weathering slightly rounded or chamfered angle and throating, finishing all exposed faces of Concrete with necessary Formwork including dismantling existing concrete work, complete all as specified and as directed. |
| 18 | M&L for Galvanized steel tubing 50 mm dia light gradefor protection of cable fixed to pole/walls or laid in floors, road crossing ducts with all necessary fittings and fittings etc including taking out existing complete all as specified and directed |
| 19 | Taking down unserviceable street light fitting upto 11 mtrs HPSV/fluorescent light fitting /CFL Fitting/LED Fitting /Flood light fitting of any size from the pole/bldg and kept in safe custody for refixing or for schedule of credit to contractorNote : All T&P ie ladder,Tools,Safty glooves etc shall be provided by the contractor without any extra cost |
| 20 | Supply and fixing 60 W LED based street light luminaries new generation energy saving & environment friendly light fitting high power LEDs as light sources.LED luminous efficiency should be > 80Lm/w.It should have active power factor correctio (APFC) electronic gear (electronic driver).Luminaire housing shall be of pressure die-cast aluminium alloy LM24 for gear and extruded aluminium lamp housing (Heat shrink for better heat transmission.It shall have epoxy powder coated grey finish phosphochromate treatment,IP-66 protection class I operating voltage range should be fron 120 volt to 270 volt AC and frequency range 50Hz.fitting should be suitable for an ambient temparature from -40°C to 50 °Cand humidity level 10% to 90% includingconnection with PVC unsheathed wirealuminium conductor 3 x 1.5sqmm with OH line or PVC junction box, complete all as specified and directed by Engr-in-charge. Make : Havells LHRD01230674 /Philips Cat No GPLS 30 LED 60W/68W LEH2 240/50Hz NP/CG Cat No LSTO60 CDL |
| 21 | Supply and fixing 45 W LED based street light luminaries new generation energy saving & environment friendly light fitting high power LEDs as light sources.LED luminous efficiency should be > 80Lm/w.It should have active power factor correctio (APFC) electronic gear (electronic driver).Luminaire housing shall be of pressure die-cast aluminium alloy LM24 for gear and extruded aluminium lamp housing (Heat shrink for better heat transmission.It shall have epoxy powder coated grey finish phosphochromate treatment,IP-66 protection class I operating voltage range should be fron 120 volt to 270 volt AC and frequency range 50Hz.fitting should be suitable for an ambient temparature from -40°C to 50 °Cand humidity level 10% to 90% includingconnection with PVC unsheathed wirealuminium conductor 3 x 1.5sqmm with OH line or PVC junction box complete all as specified and directed by Engr-in-charge. Make : Havells LHRD01230674 /Philips Cat No GPLS 30 LED 60W/68W LEH2 240/50Hz NP/ CG Cat No LSTO60 CDL |
| 22 | Supply and fixing 80 watt LED Flood light luminaire of epoxy powder cated CRCA MShousing with epoxy powder coated aluminium heat sink with system wattage .with 120 degree view angle,>100 lumen/watt,luman maintenance>70% at 50,000hrs,colr temperature of 5000-6500K,> color rendering and LM80 test compliance.The driver must be integral APFC and constant current type having THD<15% and power factor>0.95 with short circuit protection,open protection,reverse polarity protection,high voltage protection complete with all accessories pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size.The LED used in fitting is of make must be of make CREE/NICHIA/OSRAM/PHILIPS. |
| 23 | Supply and fixing 150 watt LED Flood light luminaire of epoxy powder cated CRCA MShousing with epoxy powder coated aluminium heat sink with system wattage .with 120 degree view angle,>100 lumen/watt,luman maintenance>70% at 50,000hrs,colr temperature of 5000-6500K,> color rendering and LM80 test compliance.The driver must be integral APFC and constant current type having THD<15% and power factor>0.95 with short circuit protection,open protection,reverse polarity protection,high voltage protection complete with all accessories pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size.The LED used in fitting is of make must be of CREE/NICHIA/OSRAM/PHILIPS. |
| 24 | Supply and fixing 200 watt LED Flood light luminaire of epoxy powder cated CRCA MShousing with epoxy powder coated aluminium heat sink with system wattage .with 120 degree view angle,>100 lumen/watt,luman maintenance>70% at 50,000hrs,colr temperature of 5000-6500K,> color rendering and LM80 test compliance.The driver must be integral APFC and constant current type having THD<15% and power factor>0.95 with short circuit protection,open protection,reverse polarity protection,high voltage protection complete with all accessories pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size.The LED used in fitting is of make must be of CREE/NICHIA/OSRAM/PHILIPS. |
| 25 | Supply and fixing LEDactive power factor correction (APFC) electronic gear (electronic driver) which uses 60 Nos.1W ( 60 W) high power LEDs as light sources all as directed by Engr-in-Charge. |
| 26 | Supply and fixing LEDactive power factor correction (APFC) electronic gear (electronic driver) using 45 W LEDas light sources all as directed by Engr-in-Charge. |
| 27 | M&L for GI Pipe Bracket made out of Galvanised Iron Tubing 50mm bore (dia), light grade, 1.50 METRE long bent to shape with two Nos of MS Clamp duly painted nuts and bolts as per specified for fixing Street Light Fittingincluding taking down unserviceable GI Pipe Bracket, complete all as specified and as directed. |
| 28 | M&L for GI Pipe Bracket made out of Galvanised Iron Tubing 25mm bore (dia), light grade, 1.50 METRE long bent to shape with two Nos of MS Clamp duly painted nuts and bolts as per specified for fixing Street Light Fittingincluding taking down unserviceable GI Pipe Bracket, complete all as specified and as directed. |
| 29 | M&L for time light distribution board switches of capacity 65 amps digitial timer box including- (i) contactor rating 65 amp 3pole/230V(ii) Digital timer programmable type (iii) MCB 65 Amp TPN(iv)copper wiring required for connections (v)selecter switch.The timer box out door type,mounted on GI angle iron frame of size 25x25x4mm grouted in cement concrete,including necessary excavation and earth work,connection of LT UG cable, complete all as directed by Engr in charge. |
| 30 | S&F MCB SPN 32 Amps240/415 Volts 10 KA finger proof terminal, bi-connect termination, label holder, 35 mm² terminal capacity, insulated sliding shutter, large two position dolly, to be fixed on existing DB, complete all as directed by Engineer in Charge. |
| 31 | S&F MCB SP 6 to 32 Amps240/415 Volts 10 KA finger proof terminal, bi-connect termination, label holder, 35 mm² terminal capacity, insulated sliding shutter, large two position dolly, to be fixed on existing DB, complete all as directed by Engineer in Charge. |
| 32 | Repair/mantenance of street light/security lights any type flood lights, Post Top lanterns or any other external light in its position fixed on pole/high mast/building structure or by taking down to round,if required,testing all the components /parts wiring etc. identifyingand replacing the defective components wise choke (ballast) electronic driver,igniter,capactor, lamp,lamp holder,connector,connection wire/cables,MCBetc.including refixing the fixing to its original position (if) taken down including repair,aint of street light control timer & junction box all as directed by Engr-in-chargefor the period of 11 months from the date of commencemnt of the work. Note : The rate against the above mentioned items is deemedfor cost of labour, Tools & Plants and allied expenses only. |
| 33 | NOTE FOR SER ITEM No 32(a) Cost of spare choke (ballast) electronic driver, igniter,capacitor, lamp,lamp holder connector replaces against above maintenance item will be measured and paid seperately under respective item of of schedule.(b) The contractor\"s representative will report to concerened JE E/M at 0900 hrs daily to collect the list of defective street light fitting and shall submit the completion report on the same day before 1730 hrs to JE E/M and submit the report to GE along with RAR.(c) The contractor has to rectify the defects/reports and make the street light servicable with in 24 hours from time the list of defective street lights is handed over torep by the concerened JE E/M. In case the street light is notmade functional forwhatsever reasonwith in thespecified time line,an amount of Rs. 100 per such defective street light per day will recovered from the amountdue to him through RAR /Final Bill and submit the report to GE.The contractor shall be carry out repair/maint will simultaneously both domestic & tech area by engaging seperate team of electrician/technician in order to ensure proper & timely rectification of defects. (d) The contractor shall maintain sufficient stock of spares/materials required for repair/maint of street light with the concerened JE E/M. Note :Vehicle and T&Pwill be arrange by the contractor.(e)The contractor shall be fully responsible for the safety of their labours engagedfor executing this work and they willprovideall requisite safety equipments and clothing to his men and department shall not be responsible for any mishappening/accident/injury to their labours. |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-2 Issued
Clarifications on tender conditions and amendments issued.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender