| 1 | Wiring for light/fan point/exhaust fan point/call bell point with 1.5 Sq.mm FRLS PVC insulated, Copper Conductor single core cable in surface/recessed medium class pvc conduit with piano type switch , phenolic laminated sheet , suitable size MS / wooden box and earthing the point with 1.5 sq mm FRLS PVC insulated copper conductor single core cable etc. as required |
| 2 | Group-A points |
| 3 | Group-B points |
| 4 | Group-C points |
| 5 | Wiring for light/power plug with 2X4 Sq.mm FRLS PVC insulated, Copper Conductor, single core cable in surface/recessed medium class PVC conduit along-with 1 no. 4 sq mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 6 | Wiring for circuit /Sub main wiring along with earth wire with following size of FRLS PVC insulated Copper conductor, single corecable in surface/ recessed medium class PVC conduitas required. |
| 7 | 2x2.5sq.mm.+ 1x2.5 Sq mm earth wire |
| 8 | 2x16 sq.mm + 1x6 Sq mm earth wire |
| 9 | Supplying & fixing of following piano type switch/socket on the existing switchbox/ cover including connections etc. as required. |
| 10 | 15/16 amp Switch |
| 11 | 6 pin 15/16 amp Socket outlet |
| 12 | 5/6 amp Switch |
| 13 | 3 pin 5/6 amp socket outlet |
| 14 | Supply and fixing of 5 amp to 32 amp rating,240V \"C\" curve , miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 15 | 10 Amps. (SP) |
| 16 | 20 Amps. (SP) |
| 17 | Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 18 | 63 Amp. (TPN) |
| 19 | 100 Amp. (TPN) |
| 20 | Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required |
| 21 | 40 Amp.(DP) isolator |
| 22 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. |
| 23 | 100 A, 30KA, FPMCCB |
| 24 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 25 | 8 way , Double door |
| 26 | 12 way , Double door |
| 27 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator). |
| 28 | 6 way (4+18), double door |
| 29 | Supplying & fixingmetal boxof following size( nominal size) on Surface or in recessed with suitable size of Phenolic laminated sheet cover in front including painting etc. as required. |
| 30 | 100mmx 100mm x 60 mm deep metal/wooden box |
| 31 | 180mmx 100mm x 60 mm deep metal/wooden box |
| 32 | Supplying and fixing call bell/buzzersuitable for Single phase, 230V complete as required. |
| 33 | Supplying and fixing 3 pin 5A ceiling rose on the existing junction box/wooden block including connection as required. |
| 34 | Supplying and fixing brass batten/ angle holder including connection etc. as required. |
| 35 | Installation, testing & Commissioning of ceiling fan, including wiring the down rods of standard lenth (up to30cm) with1.5 sq. mm FRLS PVC insulated, copper conductor, earthing etc. as required. |
| 36 | Supplying and fixing two modular stepped type electronic fan regulator on the existing plate/switch box including connections but excluding plate etc. as required. |
| 37 | Installation, testing & Commissioning of prewired flourecent fitting/compact flourecent fitting of all types complete with all accessories etc. directly on ceiling/wall including connections with1.5 sq. mm FRLS PVC insulated, copper conductor, earthing etc. as required. |
| 38 | Installation of Exhaust fan up to 450mm sweep in the existing opening,including making good the damage, connections, testing,commissioningetc. as required. |
| 39 | Earthing with copper earth plate 600 mm X 600 mm X 6mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 40 | Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required. |
| 41 | Supply and fixing of Indicator Lamp on exiting Switchboard |
| 42 | Supply of LED Tubelight 4ft. (20W) (Havells/Wipro/Phillips/Bajaj/syska) |
| 43 | Supply of Mirror LED Batten Light 1ft. (5W)(Havells/Wipro/Phillips/Bajaj/Syska) |
| 44 | Supply, installation, testing and commissioning of Flood light (50 Watt) (Havells/Wipro/Phillips/Bajaj/syska) |