Providing Internal And External Electrification And Electrical Appliances , Accessories And Street Lighting To Primary Health Sub Centre Building At. Bholane Tal. Jalgaon Dist. Jalgaon Providing Internal And External Electrification And Electrical Applian, jalgaon-Maharashtra

Rural Development Department has published Providing Internal And External Electrification And Electrical Appliances , Accessories And Street Lighting To Primary Health Sub Centre Building At. Bholane Tal. Jalgaon Dist. Jalgaon Providing Internal And External Electrification And Electrical Applian. Submission Date for this Tender is 20-06-2022. Electrification Work Tenders in jalgaon Maharashtra. Bidders can get complete Tender details and download the document.




Tender Notice

32672183
Providing Internal And External Electrification And Electrical Appliances , Accessories And Street Lighting To Primary Health Sub Centre Building At. Bholane Tal. Jalgaon Dist. Jalgaon Providing Internal And External Electrification And Electrical Applian
Open Tender
Indian
Maharashtra
jalgaon
20-06-2022

Tender Details

Providing Internal And External Electrification And Electrical Appliances , Accessories And Street Lighting To Primary Health Sub Centre Building At. Bholane Tal. Jalgaon Dist. Jalgaon Providing Internal And External Electrification And Electrical Appliances , Accessories And Street Lighting

Key Value

Document Fees
INR 1200 /-
EMD
INR 12000.0 /-
Tender Value
INR 11.82 Lakhs /-

BOQ Items

Name of Work: Providing Internal & External Electrification &Electrical Appliances ,Accessories & Street Lighting to Primary Health Sub Centre Building At- Bholane Tal.- JalgaonDist. Jalgaon
Sl. No. Item Description
1Supplying and erecting UPVC reinforcedflexible conduit 25 mm in dia.conforming to I.S.withrequirednumber of couplings,PVC bushes,check nuts etc. complete.
2Supplying and erecting PVC trunking (PVC casing-n-capping)ofsize32 mm with accessorieson wall/ceiling as per specification No: WG-MA/CON.
3Supplying & erecting mains with 2x1.5 sq.mmF.R copperPVC insulated wire laid in provided conduit/ trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW
4Supplying & erecting mains with 2x2.5 sq.mm F.R copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW
5Supplying & erecting mains with 2x4 sq.mm F.R copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW
6Supplying and erecting ISI mark modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete.
7Supplying and erecting ISI mark modular type switch 16A duly erected on provided plate and box with wiring connections complete.
8Supplying and erecting ISI mark modular type 3 pin 6A multi sockets with safety shutter, duly erected on provided plate and box with wiring connections complete.
9Supplying and erecting ISI mark modular type 3 pin 6 / 16A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete.
10Supplying and erecting ISI marked modular type telephone socket one gang with safety shutter, duly erected on provided plate and box with wiring connections complete.
11Supplying and erecting ISI mark modular type (two module) electronic step regulator for fan, duly erected on provided plate and box with wiring connections complete.
12Supplying and erecting ISI mark modular type blanking plate one module, duly erected on provided plate & box.
13Supplying and erecting PVC Surface modular switch box with double mounting plate for 4 modules duly erected.
14Supplying and erecting PVC Surface modular switch box with double mounting plate for 12 modules duly erected.
15Supplying and erecting 16 / 20 / 25 A starter (modular range) 2 module for AC unit on provided box complete & duly concealed with necessary material and connected.
16Point wiring in PVC trunking (casing-capping) with 1.5 sq.mm (2+1E) FR grade copper wire, modular type switch, earthingand required accessories as per specification No: WG-PW/SW
17Point wiring in PVC trunking (casing-capping) with 1.5 sq.mm (2+1E) FR grade copper wire, modular type switch, earthingand required accessories as per specification No: WG-PW/SW (Fan Point)
18Wiring for plug on board with Modular Switch socket, copper wiring and earthing as per specification No: WG-PW/SW
19Supplying & erecting telephone copper cable 4 pair with 0.5 mm dia. laid in provided PVC casing capping / conduit as per specification No. WG-TW
20Supplying & installing UTP networking cat-6 cable suitable for LAN / WAN Computer net-working as per specification No. WG-COC/NC
21Supplying & erecting5W-7W, 230V integral type LED Lamp suitable for B-22/E-27 base.
22Supplying & erectingready to use Retrofit T8 LED 18 / 20 tube lightwith polycarbonate body, heat sink, integrated HF electronic driver complete & compatible to T8/ T12LED luminaire by disconnecting starter & ballast if necessary.
23Supplying and erecting ding dong/electronic musical type call bell with heavy duty coilsuitable to operate on 230V A.Csupply erected on polished double wooden block/sunmica block of suitable size
24Supplyingand erecting LED square / circular 16 to 20W down lighter having pressure die-cast aluminium housing, opal translucent cover, mounting arrangement with board for surface type or spring loaded mounting clips for flush type complete.
25Providing and erecting bracket fan 400 mm. sweep A. C. 230 volts 50 cycles 1350 R.P.M. Oscillating type, plastic or metal bladeschromeplatedguardwithregulatorandmoisture proof treatment to winding and with ‘E’ class insulation.
26Supplying and erecting fan hook of 10 mm. M.S. round bar grouted in RCC slab with making the site as original.
27Supplying and erecting five star rated energy saving Ceiling fan 230 V A.C. 50 cycles 1200 mm complete erected in position as per specification no. FG-FN/CF
28Supplying and erecting fresh air cum exhaust fan of light duty 250 V A.C. 50 cycles 300mm. 1400 RPM rust proof body & blades, wire mesh, duly erected in an approved manner.
29Supplying, installing, testing and commissioning of 1400 VA to 1600 VA Digital pure sine waveinverter based on Insulated Gate Bipolar Transistor (IGBT) technology single phase 230V,50 Hz completeas per specification no.AP-INV (Without batteries)
30Supplying, installing, testing and commissioning of 800 VA to 900 VA Digital pure sine wave inverter based on Insulated Gate Bipolar Transistor (IGBT) technology single phase 230V,50 Hz completeas per specification no.AP-INV (Without batteries)
31Supplying and erecting 12 V/180Ahtubular battery with battery terminal wire, duly charged complete with 36 months warranty complete
32Supplying, installing, testing and commissioning of FPC solar waterheatingsystemwithoutheat exchangertype of 500 LPD capacity a complete. Specification no. ESD-SHWS-FPC
33Supplying and erecting 20/25 mm (ID/OD) polyethylene composite pipe duly joined by compression/crimp fitted accessories, with internal as well as external end sealing arrangement for solar water heater system complete. Specification no. (ESD-HWP/PCP)
34Supplying and erecting triple pole metal clad switch and fuse 415V, 100A on angle iron / GI frame as per specification no. SW-SWR/MTP.
35Supplying, erecting & marking SPMCB 6A to 32A, C-series (for motor/power) in provided distribution board as per specification no. SW-SWR/MCB
36Supplying, erecting & marking SPMCB 6A to 32A, B- series (for lighting) in provided distribution board as per specification no. SW-SWR/MCB
37Supplying, erecting & marking DPMCB 40A to 63A, C- series (for motor/power) in provided distribution boardas per specification no. SW-SWR/MCB
38Supplying, erecting & marking TPMCB 40A to 63A in provided distribution board as per specification no. SW-SWR/MCB
39Supplyinganderectingtriplepole and neutral distribution board (TPNDB) surface/ flushmounted suitable for SPMCB of 12 wayson iron / GI frame (horizontal busbar type)as per specification no. SW-SWR/MCBDB
40Providing, erecting and commissioning 2 pole RCCBonly ofelectromagnetictype with 30/100/300 mA sensitivity and having capacity of 40A completeas per specification no. SW-RCCB/RCCB
41Supplyinganderectingiron, sheet metal work consisting of CRCAsheets, varioussectionsofiron,plates, chequeredplates,rods,bars,MSpipes,etc. forpanel board or any other purpose with bending, cutting, drilling and welding completeerectedatthepositionwith necessarymaterialsdulypaintedwith one coat of red oxide and two coats of enamelpaint to match the switchgears or as per directions by the authority.
42Supplying and erecting bus bar chamber triple pole with neutral with four copper bars, 500V, 100A complete as per specification no. CP-BB
43Supplying, erecting & terminatingXLPE armoured cable 3 core25sq. mm.aluminium conductor withcontinuous5.48 sq. mm. (12 SWG) G.I. earth wire completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. CB-LT/AL
44Providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results asper specification no. EA-EP
45Supplying and erectingaluminium strip of required sizes used for earthing on wall and/or any other purpose with necessaryaluminiumclampsfixed on wall painted with bituminous paint in an approved manner with joints required. As per specification no EA-EP.
46Supplying & installing one piece moulded HDPE / fibre water tank for negative suction only, having capacity 1000litres fitted with necessary accessories complete asper specification no. FF-FFA/PT
47Supplying anderectingLED street light fitting suitable for 60W lamp, including lamp, with PF >0.95 class IP65 and above housing of pressure die cast aluminium alloy and heat sink extrudedaluminiumcompleteas per specificationNo FG-ODF/FLS-2.
48Supplying, installing, testing and commissioning solar street lightpolecomprising of14W LEDfitting,12V 36Ah maintenance free lithium battery, min. 75Wp SPV module, MS powder coated battery box weather proof, mounted on 75/80 mm dia. B-Grade GI pole of 6 m. height along with brackets,foundation,earthlingand necessaryaccessories complete.Specificationno.ESD-SOL-STL(with 5 years warrantee )
49Supplyingand erectingStreetlight bracketfor erectionof side entry fitting on pole with 40 mm. dia. ‘B’ grade G.I. pipe ofrequiredlengthcompleteasperspecificationno.FG-BKT /SLB
50Supplying,erecting & terminatingXLPE armoured cable 2 core 6 sq. mm. aluminium conductor withcontinuous5.48 sq. mm. (12 SWG) G.I. earth wire complete erectedwith glands & lugs, on wall/ trusses/pole or laid inprovided trench/ pipeas per specification no.CB-LT/AL
51Supplying & erecting FRP box of size 150 x 125 x 100 mm, 2.7 mm thickcomplete on pole/wallas per specification no. CB-SB
52Supplyingand erecting ISI mark G.I.pipe pole‘B’grade 80 mm dia 6 m longwith pole cap, base plate in provided foundation as per specification no. OH-PL/GIP
53Providingpipetype earthing with 40mm. dia. G.l. pipe or 20 mm dia. G.l. Rodcomplete with all materials as per specification no. EA-EP
54Supplying and erecting Centrifugal water pump (Monoblock),230V, Single phase 50 cycles A.C. supply of0.75 KW/1 HP with discharge 1.6/2.9 Litres per second (LPS) for head of 9/22 m& 40 mm suction/ 40 mm delivery pipe on provided C.C. foundation as per specification no. WP-CGP
55Making trench of suitable width and depth in hard murum / tar roadfor laying provided LT cable up to and including16 sq. mm complete as per specification no. CW-EXN-CTR
56Making cementconcrete foundation including excavation (45 x45x120 ) cm deep in 1:3:6 cement concrete, 20 to 25 mm stone metal, (45x45x45) cm/45 cm dia.x45 cm heightplinthdulyplastered, withnecessarycuringand finishing complete. (for 6 m pole)
57Supplying & erecting G.I. pipe‘A’ class 40 mmdia.erectedfor enclosingXLPE armoured cable on wall/poleas per specification noCB-CE
58Supplying, installing, testing and commissioning split type variable speed Inverter technology room Air conditioning unit 1.5 TR Capacity havingISEER minimum3.50 to maximum3.99 suitableto operateon 250V,50 cycles, A.C.supply having 1 no. of air handling unit hiwall/floor mounting type complete with refrigerant R410 A/R32 and copper condenser at position. specification no. APAC/ SAC
59Supplying&erectingsoftdrawncopperpipesuitablefor refrigeration system having 22 SWG thickness and inner dia / size 22 mm complete.
60Supplying,erecting,testing and commissioningself- contained water cooler 230/250V 50 cycles nominal cooling capacity of 40 litres/hr and storage capacity 80 litres with partially stainlesssteelbody complete.specification no.APWCR/ WC
61Supplying and erecting ultra violet storage type water purifier ( RO+UV+UF) with softener for safe drinking water consisting of UV germicidal tube of 8W capacity choke made of copper wire and two indicator lamps with output of purified water 7 to8 litre/min with activated carbon filter and softener operating on 230 V single phase A.C. supply.
62Supplying and erecting ISI mark GI pipe 20 mm dia.‘B’ class at position with accessories complete. Specification no. CW- PLB/GP.
63Supplying, installing, testing and commissioning of 1 kWp capacity on grid solar power pack with GI mounting structure and inter connecting wires / cables without battery bank SPV modules and solar power conditioning unit of required capacity complete, with 5 years on site performance warrantee. Specification no. ESD-RT-ONG As per Note For Item 4-6-1 Add 57145/-per kWp so For 3kWp System Rate = 57143+57145+57145*10%=188576.30
64Supplying, fixing and commissioning MCB type change over switch 2 pole, 25 A with 3 positions (I-O-II) with centre off position as per specification no. SW-SWR/MCBCOS
65Supplyingand erecting single pole and neutral distributionboard (SPNDB) with door surface/flush mounted with 2 waysfor incoming and 2 ways for outgoing SP MCB’son iron/ GI frame as per specification no. SW-SWR/MCBDB
66Supplyinganderectingsingle phase 10 to 60 A net meter of accuracy class 1.0, 240V, 50 Hz,with backlitLCD display, optical port ( measures import kWh, export kWh, net kWh, V, I, kW, 12 months history of energy)with wiring connections and mountinghardwareonprovidedpanelscompletewith calibration certificate from manufacturer.
67Supplying and erecting marine plywood 18/19 mm thick fixed to wall or on provided panel board with necessary materials such as screws, wall fasteners, supports, nut bolts etc. complete.
68Supplying and erecting GI sheet 1.6 mm (16 SWG)tobeused for fabricationofboxespanelboardsetc. including cutting, bending, drilling, welding, riveting etc. and paintingwithone coat of red leadpaint and 2 coats of enamel paint.
69Add GST 12%
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy