The Work Of Design, Engineering, Supply, Erection, Commissioning And Laying Of 11 Kv Cable, 415V Mccb And Various 415 V Cables At Gbps, Utran- Alluminium Cable 3 Corex185 Sqmm Ht, 1100 V Grade, 4C X 2.5 Mm2 Tinned Copper Cable, End Cable Jointing Kit Heat Shrinkable Type For 11 Kv 3 Core 185 Sq Mm Xlpe Cable, Raychem Make 6.6Kv Ht Cable Termination Kits And Accessories Suitable For 3C X 240 Sq.Mm, Comet Make 1.1 Kv End Termination Kits With Lugs, Glands Etc Suitable For 4C X 2.5 Sqmm ( Frls Type ) , Triple Pole Moulded Case Circuit Breaker Rated 400A, 65Ka, Pvc - Alluminium Cable Armoured 3 Corex150 Sqmm Conf To Is-1554, 3C X 70 Sqmm Power Cable Lead Coted 650 / 1100 V, Comet Make 1.1 Kv End Termination Kits With Lugs, Glands Etc Suitable For 3C X 150 Sq.Mm Al Cond ( Frls Type ) , Comet Make 1.1 Kv End Termination Kits With Lugs, Glands Etc Suitable For 3C X 70 Sq.Mm Al Cond ( Frls Type ) , 3.5 C X 50 Sq.Mm Aluminium Xlpe Armoured Power Cable, Voltage Grade : 1100 V, 3.5 C X 35 Sq.Mm Aluminium Xlpe Armoured Power Cable, Voltage Grade : 1100 V, Cable End Termination, For 3.5C X 50 Sq.Mm Cable Including Required Size Of Gland, Lugs And All Required Sundry Materials., Cable End Termination, For 3.5C X 35 Sq.Mm Cable Including Required Size Of Gland, Lugs And All Required Sundry Materials., Laying Of 3Cx185 Sq.Mm 11 Kv Xlpe Cable In Underground / Cable Trench Etc As Per Site Routing., Laying Of 1.1 Kv 4Cx 2.5 Sq.Mm, Armoured, Copper Control Cable In Underground / Cable Trench Etc As Per Site Routing Including Termination And Glands., Fixing Of Cable End Termination Kit For 3Cx185 Sq.Mm 11 Kv ( E ) , Xlpe Cable, Fixing Of Cable Straight Joint Termination Kit For 3Cx185 Sq.Mm 11 Kv ( E ) , Xlpe Cable., Fixing End Termination For 4Cx 2.5 Sq.Mm Cable, Installation And Commissioning Of 415 Volt, 3 Pole, 400 A Mccb For Feeders To Be Retrofitted In Existing Vacant Module Having Size :-790Mm ( H ) X470mm ( W ) X290mm ( D ) . ) , Laying Of 1.1 Kv 3C X 150 Sq.Mm Armoured Aluminium Cable In Underground / Cable Trench Etc As Per Site Routing. ( For Rwph Supply-4 Run ) , Laying Of 1.1 Kv 3Cx 70 Sq.Mm, Armoured Aluminium Cable In Underground / Cable Trench Etc As Per Site Routing. ( Filter Plant-Single Run ) , Fixing End Termination For 3Cx 150 Sq.Mm Cable, Fixing End Termination For 3Cx 70 Sq.Mm Cable, Laying Of 3.5C X 50 Sq.Mm Cable In Underground / Cable Trench Etc As Per Site Routing. ( For Street Light Supply-2 Run ) , Laying Of 3.5C X 35 Sq.Mm Armoured Aluminium Cable Including Supply And Fixing Of Required Size Of Gland, Lugs And All Required Sundry Materials In Existing Cable Trench And / Or In Ground. ( For Street Light Supply-4 Run ) , Fixing End Termination For 3.5C X 50 Sq.Mm Cable, Fixing End Termination For 3.5C X 35 Sq.Mm Cable, Installation Of 415 Ac Power Supply Distribution Boards For Street Lighting At Various Location Including Supply And Fixing Of Required Size Of Gland, Lugs And All Required Sundry Materials. ( Db Is Provided By Gsecl ) , Contingency Items For Works And Supply