Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 06-07-2022 | DATE | Date | 19-07-2022 |
| 2 | 30-06-2022 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 07-07-2022 |
| Sl. No. | Item Description |
| 1 | Schedule \"A\" Section - I |
| 2 | Excavation in trenches in hard dense soil n.exc 1.5 mtr wide & n.exc 1.5mtr in depth and n. exc. 10sqm on plan for laying pipe in trenches and getting out complete allas specified and directed. |
| 3 | Returning filling in trenches, spreading, levelling, watering and well ramming in layers n.exc 25cm in hard dense soil complete all as specified and directed. |
| 4 | Removing of surplus soil to a distance n.exc 50 mtr and depositing where directed at a level n.exc 1.5 mtr above starting point complete all as specified and directed. |
| 5 | Taking out unserviceable/defective/damaged/blockage GI/MS pipe 15 mm bore steel water tubing,sorting out serviceable pipe fitting for reuse and cleaning the pipe including fitting and removing away all unserviceable pipe from site, complete all as specified and as directed. (Note: Exacavation and earhwork shall be measured and paid for separately.) |
| 6 | All as per serialitem No. 4.00 here-in-before but of size 20mm bore-ditto-. |
| 7 | All as per serialitem No. 4.00 here-in-before but of size 25 mm bore-ditto-. |
| 8 | All as per serialitem No. 4.00 here-in-before but of size 40mm bore-ditto-. |
| 9 | All as per serialitem No. 4.00 here-in-before but of size 50mm bore-ditto-. |
| 10 | All as per serialitem No. 4.00 here-in-before but of size 80mm bore-ditto-. |
| 11 | All as per serialitem No. 4.00 here-in-before but of size 100mm bore-ditto-. |
| 12 | All as per serialitem No. 4.00 here-in-before but of size 150mm bore-ditto-. |
| 13 | S&F steel watertubing medium grade, ISI Marked conforming to IS 1239 Part-I 2004, 15mm bore with and including all fittings such as bends , elbows,tees, short length , socket, union, check nuts, nipples and weldings etc. fixed and laid in trenches/floor/under culvert/road crossing etc including testing complete all as specified and as directed. |
| 14 | All as per serialitem No. 12.00 here-in-before but of size 20mm bore-ditto-. |
| 15 | All as per serialitem No. 12.00 here-in-before but of size 25mm bore-ditto-. |
| 16 | All as per serialitem No. 12.00 here-in-before but of size 40mm bore-ditto-. |
| 17 | All as per serialitem No. 12.00here-in-before but of size 50mm bore-ditto-. |
| 18 | All as per serialitem No. 12.00here-in-before but of size 80mm bore-ditto-. |
| 19 | All as per serialitem No. 12.00here-in-before but of size 100mm bore-ditto-. |
| 20 | All as per serialitem No. 12.00here-in-before but of size 150mm bore-ditto-. |
| 21 | S&F in replacement of Bronze gate valve for 15mm bore pipe,with iron wheel head, screwed both ends for iron pipe and fixed, ISI marked conforming to IS 778: 1984, fixed as in repair complete all as specified and directed. |
| 22 | All as per serialitem No. 20.00 here-in-before but of size 20mm bore-ditto-. |
| 23 | All as per serialitem No. 20.00 here-in-before but of size 25mm bore-ditto-. |
| 24 | All as per serialitem No. 20.00 here-in-before but of size 40mm bore-ditto-. |
| 25 | All as per serialitem No. 20.00 here-in-before but of size 50mm bore-ditto-. |
| 26 | Taking out old unsv and Supplying, fixing and testing of cast steel Sluice valve PN1.6 as per IS-14846, body, dome, wedge-CI IS:210, rings-bronze IS:318, Spindal-SS IS:6603, Gland Paking greasy jute packing, fasteners-CS, Gasket- Natural rubber, nominal size DN-150 mm, both ends flanged in existing line,afterremoval of old unserviceablesluice valve without damagingtoexistingpipeline complete all as specified and directed by Engr-in-charge. . Note : Suitable size flanges for existing pipe line, Joints and jointing materials shall be included under this item. |
| 27 | All as per serialitem No. 25.00 here-in-before but nominal size DN-100 mm-ditto-. |
| 28 | All as per serialitem No. 25.00 here-in-before but nominal size DN-80 mm-ditto-. |
| 29 | S&F Cast iron Non Return valve W/O by pass arangement , Swing type, of Size 100 mm bore, confirming to IS 5312, flanged ends with nuts bolts, washers complete including taking down of old one . |
| 30 | S&F Cast iron Non Return valve W/O by pass arangement , Swing type, of Size 150 mm bore, confirming to IS 5312, flanged ends with nuts bolts, washers complete including taking down of old one . |
| 31 | Supply and fix Cast Iron Air Release Valves with two air Outlets, conforming to IS 14845 of size 100 mm dia bore and fixing up in Cast Iron Water supply mains of size 100 mm dia. |
| 32 | Supply and fix Cast Iron Air Release Valves with two air Outlets, conforming to IS 14845 of size 150 mm dia bore and fixing up in Cast Iron Water supply mains of size 150 mm dia. |
| 33 | Construction ofbrick masonary pit of size 60 x 60 x 60cm internal size with MS sheet 3mm thick and angle iron frame of size 40x40x6mm duly paintedwith 2 coats of synthetic enamel paint over a coat of red oxide primer including locking arrangement, lifting handle and including excavation / earth work, PCC in foundation, brick work, plaster including demolition of existing pit complete all as specified and shown in drawingNo. STD- 1258, sheet 1/1. (original date - 30.11.93 and revised date - 15.09.2000 ) Note : Drawing mentioned above has not been enclosed herewith, however the same can be seen in the office ofGE Kasauli. |
| 34 | Construction ofbrick masonary pit of size 90 x 90 x 90 cm internal size with MS sheet 3mm thick and angle iron frame of size 40x40x6mm duly paintedwith 2 coats of synthetic enamel paint over a coat of red oxide primer including locking arrangement, lifting handle and including excavation / earth work, PCC in foundation, brick work, plaster including demolition of existing pit complete all as specified and shown in drawingNo. STD- 1258, sheet 1/1 (original date - 30.11.93 and revised date - 15.09.2000 ) Note : Drawing mentioned above has not been enclosed herewith, however the same can be seen in the office ofGE Kasauli. |
| 35 | Construction ofbrick masonary pit of size 120 x 120 x 120 cm internal size with MS sheet 3 mm thick and angle iron frame of size 40x40x6mm duly paintedwith 2 coats of synthetic enamel paint over a coat of red oxide primer including locking arrangement, lifting handle and including excavation / earth work, PCC in foundation, brick work, plaster including demolition of existing pit complete all as specified and shown in drawingNo. STD- 1258, sheet 1/1 (original date - 30.11.93 and revised date - 15.09.2000 ) Note : Drawing mentioned above has not been enclosed herewith, however the same can be seen in the office ofGE Kasauli. |
| 36 | S&Fin replacement of Water meter 100 mm nominal bore conforming to IS:2373-1981 having CI casing bronze body and SS/Alloy/Bronze gear having dial duly marked with litres or kilolitres in boldface, thread/flanged end type with provision of strainer out side the meter complete all as specified and as directed . Make - Kranti/Deshmesh/L&T. |
| 37 | Supply of calcium hypo chloride, 65%-70% chlorine content, high strength granular disinfectant for treatment of drinking water complete all as specified and qty as per requirement and as directed by Engr-in-Charge. |
| 38 | S&F in replacement of Foot Valve conforming to IS-4038 flanged ISI marked completed with nut, bolts, washers etc including taking out old existing u/s foot valve of 100 mm dia. |
| 39 | M&L for complete servicing/ cleaning of DG Setswith kerosene or by blower where necessary , prevention of leakage of fuel /oil/ water/coolant, tightening of loose nuts and bolts , retensioning of fen belt, descaling of radiator cleaning with cleaning agent, cleaning of fins by applying pressurised air using blower including replacement of rubber housing set complete , checking of all electrical connections and testing on full load of DG sets with taking out and replacement of defrective parts.Notes:-The quoted rates of the contractor includes for (i) Fixing the serviceable parts in position and replacement of unserviceable parts with new parts.(ii) Supply and replacement ofsmall/minor parts such as nuts, bolts, washers, locking nuts, small springs, studs etc and parts mentioned in the item above.(iii) Labour for replacement of lubricating oil (Cost of lubricating oil shall be measured and paid separately)(iv) Make of DG sets installed are one of the make mentioned in the item.Spare parts to be replaced shall be suitable for the same make and model of engine as installed at site and serviced. (v) Major parts required to be replaced shall be measured and paid separately under respective items of BOQ. |
| 40 | DG set 30 KVA , Make:-Mahindra by Powerol Installed at Signal Centre Kasauli |
| 41 | DG Set 62.5 KVA Make: Kirloskar Installed at 95 Inf Bde Camp Kasauli |
| 42 | DG Set 125 KVA Make: Mahindra by PowerolInstalled at Military Hospital Kasaulli |
| 43 | DG Set 380 KVA Make: Cummins Installed at P2 (Nauti Goan) W/S installation |
| 44 | DG set 10 KVA , Make :-Kirloskar Installed at Installed at Signal Centre Dagshai |
| 45 | DG set 45 KVA , Make :-Kirloskar Installed at Installed at Section Hospital Dagshai |
| 46 | DG Set 100 KVA Make: Mahindra installed at Dhobi ghat W/S installation at Dagshai |
| 47 | DG Set 200 KVA Make: Crompton Ltd Installed at Patta Ka More W/S installation |
| 48 | Supply only totop up ofCoolant for the DG Sets complate all as specified and directed . |
| 49 | Supply and filling /top up of Distilled water for the batteries of the DG Sets complete all as specified and as directed. |
| 50 | Supply only of Engine belt off size for 30 KVA DG Set (set of two)complete all as specified and directed. |
| 51 | All as per serial item No 41.00 above but 62.5 KVA DG Set. |
| 52 | All as per serial item No 41.00 above but 125 KVA DG Set. |
| 53 | All as per serial item No 41.00 above but 380 KVA DG Set (set of three). |
| 54 | Supply only of Engine belt off size for10 KVA DG Set(set of two)complete all as specified and directed. |
| 55 | All as per serial item No 45.00 above but 45 KVA DG Set. |
| 56 | All as per serial item No 45.00 above but 100 KVA DG Set. |
| 57 | All as per serial item No 45.00 above but 200 KVA DG Set. |
| 58 | Supply only of Diesel filter element with gasketfor 30 KVA DG Set complete all as specified and directed . |
| 59 | All as per serial item No 49.00 above but 62.5 KVA DG Set. |
| 60 | All as per serial item No 49.00 above but 125 KVA DG Set. |
| 61 | All as per serial item No 49.00 above but 380 KVA DG Set. |
| 62 | Supply only of Diesel filter element with gasketfor10 KVA DG Set complete all as specified and directed . |
| 63 | All as per serial item No 53.00 above but 45 KVA DG Set. |
| 64 | All as per serial item No 53.00 above but 100 KVA DG Set. |
| 65 | All as per serial item No 53.00 above but 200 KVA DG Set. |
| 66 | Supply only of Oil filter element completefor 30 KVA DG Set complete all as specified and directed . |
| 67 | All as per serial item No 57.00 above but 62.5 KVA DG Set. |
| 68 | All as per serial item No 57.00 above but 125 KVA DG Set. |
| 69 | All as per serial item No 57.00 above but 380 KVA DG Set. |
| 70 | Supply only of Oil filter element completefor 10 KVA DG Set complete all as specified and directed . |
| 71 | All as per serial item No 61.00 above but 45 KVA DG Set. |
| 72 | All as per serial item No 61.00 above but 100 KVA DG Set. |
| 73 | All as per serial item No 61.00 above but 200 KVA DG Set. |
| 74 | Supply only of Air cleaner Element complete Set for 30 KVA DG Set complete all as specified and directed . |
| 75 | All as per serial item No 65.00 above but 62.5 KVA DG Set. |
| 76 | All as per serial item No 65.00 above but 125 KVA DG Set. |
| 77 | All as per serial item No 65.00 above but 380 KVA DG Set. |
| 78 | Supply only of Air cleaner Element complete Set for 10 KVA DG Set complete all as specified and directed . |
| 79 | All as per serial item No 69.00 above but 45 KVA DG Set. |
| 80 | All as per serial item No 69.00 above but 100 KVA DG Set. |
| 81 | All as per serial item No 69.00 above but 200 KVA DG Set. |
| 82 | Supply only of Air filter (inner & outer)complete Set for 30 KVA DG Set complete all as specified and directed . |
| 83 | All as per serial item No 73.00 above but 62.5 KVA DG Set. |
| 84 | All as per serial item No 73.00 above but 125 KVA DG Set. |
| 85 | All as per serial item No 73.00 above but 380 KVA DG Set. |
| 86 | All as per serial item No 73.00 above but 10 KVA DG Set. |
| 87 | All as per serial item No 73.00 above but 45 KVA DG Set. |
| 88 | All as per serial item No 73.00 above but 100 KVA DG Set. |
| 89 | All as per serial item No 73.00 above but 200 KVA DG Set. |
| 90 | Supply only of New nylon reinforced PVC fuel pipe complete Set for 30 KVA DG Set complete all as specified and directed . |
| 91 | All as per serial item No 81.00 above but 62.5 KVA DG Set. |
| 92 | All as per serial item No 81.00 above but 125 KVA DG Set. |
| 93 | All as per serial item No 81.00 above but 380 KVA DG Set. |
| 94 | Supply only of New nylon reinforced PVC fuel pipe complete Set for 10 KVA DG Set complete all as specified and directed . |
| 95 | All as per serial item No 85.00 above but 45 KVA DG Set. |
| 96 | All as per serial item No 85.00 above but 100 KVA DG Set. |
| 97 | All as per serial item No 85.00 above but 200 KVA DG Set. |
| 98 | M & L forreplacement of battery 12V, 180 Ah maintenance free forDG sets with Electro plates including battery lead positive & negative battery terminals complete all as specified and as directed. |
| 99 | Draining out old Engine oil from Chamber, cleaning of oil sump complete and filling of new oil confoming to specification. |
| 100 | Taking downand repair to self starter by taking out defective parts and repacement of armature , field coils, carbon bush, pinion, shocker arm, bearing complete including testing all as specified and as directed. |
| 101 | Overhauling of FIP Pump & calibration complete all as specified of the DG Set 30 KVA complete all as specified and as directed. |
| 102 | All as per serial item No 92.00 above but 62.5 KVA DG Set. |
| 103 | All as per serial item No 92.00 above but 125 KVA DG Set. |
| 104 | All as per serial item No 92.00 above but 380 KVA DG Set. |
| 105 | Overhauling of FIP Pump & calibration complete all as specified of the DG Set 10 KVA complete all as specified and as directed. |
| 106 | All as per serial item No 96.00 above but 45 KVA DG Set. |
| 107 | All as per serial item No 96.00 above but 100 KVA DG Set. |
| 108 | All as per serial item No 96.00 above but 200 KVA DG Set. |
| 109 | Material and labour for servicing / repairs of 380 KVA alternator and removing the same from engine of 380 KVA DG set and servicing and cleaning of alternator carbon brush assembly including commutor, slip rings, carbon brushes and brush holders , checking of commutor, brushes, AVR complete and refixing the same in its existing position after servicing back to the site and connecting up electric connections with suitable lugs complete and testing complete all as specified and directed. |
| 110 | Taking out exhuast unit from 30 KVA DG set for cleaning of silencer , Silencer pipe by using wire brush ect and refix in the same position with necessary welding nut and bolts complete all as specified and as directed. |
| 111 | All as per serial item No 101.00 above but 62.5 KVA DG Set. |
| 112 | All as per serial item No 101.00 above but 125 KVA DG Set. |
| 113 | All as per serial item No 101.00 above but 380 KVA DG Set. |
| 114 | Taking out exhuast unit from 10 KVA DG set for cleaning of silencer , Silencer pipe by using wire brush ect and refix in the same position with necessary welding nut and bolts complete all as specified and as directed. |
| 115 | All as per serial item No 105.00 above but 45 KVA DG Set. |
| 116 | All as per serial item No 105.00 above but 100 KVA DG Set. |
| 117 | All as per serial item No 105.00 above but 200 KVA DG Set. |
| 118 | Earthing complete with galvanised steel earth plate electrode of size 600x600x6mm thick, buried directly in ground (earth pit not less than 2.25m deep below normal ground level) with top dedge of the plate not less than 1.50m below normal ground level, connected to galvanised iron strip 32x6mm as earthing lead by means of suitable GI nuts/bolts and brazed properly up to main board including earth pit in cement concrete 1:2:4 type B-1, precast RCC cover in 1:2:4 reinforced with expanded metal, with suitable handle, excavation and earth work in any type of soil and including light grade GI watering pipe 25mm bore and 40mm bore light grade for strip protection with funnel wire mesh complete as shown in electrical plate No 5 of MES schedule Part-I 2009, connected to earthing testing point. Note - The unit rate including the cost of excavation & earth work in any type of soil, charcoal & salt in alternate layers, 25mm GI Pipe (Light grade) for watering, 40mm dia pipe (light grade)funnel wire mesh PCC chamber in PCC 1:3:6 type C-1 cast iron frame and 40mm thick RCC cover for pit etc & no extra payment will be made. |
| 119 | Taking down carefully aluminium /GI strip of any size and type from site complete, all as specified and directed. |
| 120 | M&L for fixing in replacement of aluminum strip of size 25 x 3.15 mm with saddles from above test point to Air Termination rods inter connections including brazing for joints copper/brass nuts , bolts /washers with insulators for necessary fixing on wall/laid on roof conductors and down conductors above ground complete all as specified and directed . |
| 121 | Labour for fixing only aluminium strip of size 25 x3.15mm with saddles from above test point to Air Termination rods inter connections including brazing for joints copper/ brass nuts , bolts /washers with insulators for necessary fixing on wall /laid on roof conductors and down conductors above ground complete specified and directed. |
| 122 | M&L for fixing inreplacement of galavanised iron strip of size 32 x 6 mm for earth continuity from test point to aluminium conductors above for inter connections including brazing for joints copper/brass nuts, bolys/ washers with insulators for necessary fixing on wall/trenches etc complete, all as specified and directed. |
| 123 | M&L for fixing in replacement of Air termination, single pointed aluminum rod 12 mm dia and 300 mm long laying at proper distance as per direction of Engr-in-Charge incl all cutting /welding complete, all as specified and directed. |
| 124 | M&L for fixing in replacement of test point terminal block made of gun metal or phosphorous bronze of size 75x 75x75 mm drilled and screwed incl 3 Nos 8 mm dia head screw complete, all as specified and directed. |
| 125 | Dismantling of Solar Water Heating system Collector or tubes type and Suppy & Fixingnew, evacuated tube type panel set of 500 LPD to 1000 LPD capacity complete with side holder necessary modification to the bracket fram/ inlet/ out let connection of water incl connected accessories complete all as per specified and directed. |
| 126 | S&F in repair hot water pipe line upto 25mm dia (heavy grade) duly insulated with glass wool/ any other heat insulating material not less that 50mm thick layer including and aluminium cladding by 1.5 mm thick sheet, over the insulation firmly locked in perfect round shape complete all as per specified and directed. |
| 127 | S&Fin replacementHeating Element capacity 2/3.0KW(as per existing sample) ISI Marked round/ tringular base, push type or thread type including rubber washersuitable for Solar water heater of capacity 500 Ltrs to 1000 Lts capacity including taking down unserviceable complete all as specified and as directed. |
| 128 | S&F Thermostat ISI Marked, (as per existing sample) suitable for Solar water heater of capacity 500 Ltrs to 1000 Lts capacity including taking down unserviceable complete all as specified and as directed. |
| 129 | M&L for repairing of tank leakage with company soldering of Solar water heater (any make) of capacity 500 Ltrs to 1000 Ltrs on existing place by Authorised and existing company with testing by Company rep after repaired till deleivery of waterand incl all connected accessories complete incl taking down/ opened/ replaced the parts complete all as per specified and directed.Note (i) Make of Spares/ Servicing/ replacement of parts will be carried out by Auth service agency of existing make of Solar Water Heater). |
| 130 | M&L for servicing/maintenance of Refrigerator of any capacity in situ by cleaning of complete external surface, internal surface, trays, racks with required chemical solution removing all dirt, strains complete checking serviceability of electrical circuit of unit, thermostat knob, fans if provided in frost free model, relays, thermostat, trays including replacement of unserviceable spares such as relays, thermostat, trays and testing after completion to entire satisfaction of Engr-in-Charge as well as user unit for Make of Refrigerator-Samsung/LG/Bluestar/Whirlpool. Note: (i) Spares require for replacement on minor repair as mentioned shall be measured and paid as supply only under appropriate item of this schedule and labour charges shall deemed to be included in the quoted rate of this item. (ii) Items require for major repair shall be measured and paid as M&L under appropriate item of this schedule and rate shall be exclusive of quoted rate of this item. |
| 131 | Supply only following company recommended spares as per original of refrigerator any cap after dismentling taking out unsv one for make of refrigerator -Samsung/LG/Bluestar whichever applicable. |
| 132 | Starting relay |
| 133 | Thermostat |
| 134 | Bottle support as per existing make & model |
| 135 | Chiller trays small as per existing make & model |
| 136 | Sliding trays large as per existing make & model |
| 137 | Supply & fix new company sealed reciprocating compressor unit for refrigerator Make-Samsung/LG/Bluestar whicever applicable of capacity 190 ltr to 321 ltr with required nuts, bolts & washers,connecting necessary copper tubings by gas welding/brazing, gas charging with R-134A after dismentling/taking out existing unserviceable/burnt compressor unit from the refrigerator in wksp and and testing after completion to entire satisfaction of Engr-in-Charge and user unit. Note: (i) Compressor unit shall be 1st quality with compitable model and make of compressor shall be as recommended by the manufacturer of Refrigerator. (ii) Gas charging shall be measured and paid separately under appropriate item of this schedule. (iii) Company test certificate and warantee certificate shall be submitted to dept. |
| 138 | Supply & fix new condenser unit for refrigerator Make-Samsung/LG/Bluestar whicever applicable of capacity 165 ltr to 310 ltr with required nuts, bolts & washers,connecting necessary copper tubings by gas welding/brazing, gas charging with R-134A after dismentling/taking out existing unserviceable unit from the refrigerator in situ and and testing after completion to entire satisfaction of Engr-in-Charge and user unit. Note: (i) Condenser unit shall be compitable model and make shall be as recommended by the manufacturer of Refrigerator. (ii) Gas charging shall be measured and paid separately under appropriate item of this schedule. |
| 139 | M&L for servicing/maintenance of Deep Freezer of capacity 200L/310L Make-Blue Star/LG /Voltas in situ by cleaning of complete external surface, internal surface, trays, racks with required chemical solution removing all dirt, strains complete and checking serviceability of electrical circuit of unit, condenser unit, relays, thermostat, trays including replacement of unserviceable spares such as relays, capacitors, thermostat, trays and testing after completion to entire satisfaction of Engr-in-Charge as well as user unit. Note: (i) Spares require for replacement on minor repair as mentioned shall be measured and paid as supply only under appropriate item of this schedule and labour charges shall deemed to be included in the quoted rate of this item. (ii) Items require for major repair shall be measured and paid as M&L under appropriate item of this schedule and rate shall be exclusive of quoted rate of this item. |
| 140 | Supply only following company recommended spares as per original of Deep freezer of cap 200/310 Ltr suitable for Make- Blue Star/LG /Voltas whicheve applicable |
| 141 | Over load protector |
| 142 | Starting relay |
| 143 | Thermostat |
| 144 | Running capacitor 4 to 25 mfd |
| 145 | Sliding trays small as per existing make & model |
| 146 | Sliding trays large as per existing make & model |
| 147 | PVC fan for blower motor |
| 148 | Supply & fix new company sealed reciprocating compressor unit with required nuts, bolts & washers,connecting necessary copper tubings by gas welding/brazing, gas charging with R-134A, replacement of capilary tube and oil filter after dismentling/taking out existing unserviceable/burnt compressor unit from the Deep freezer 200/310 capacity and and testing after completion to entire satisfaction of Engr-in-Charge and user unit suitable for DF Make-Blue Star/LG /Voltas whichever applicable.Note: (i) Compressor unit shall be 1st quality with compitable model and make of compressor shall be as recommended by the manufacturer of DF. (ii) Gas charging shall be measured and paid separately under appropriate item of this schedule. (iii) Company test certificate and warantee certificate shall be submitted to dept. |
| 149 | Supply and fix condenser coil unit of Deep freezer 200/310 Ltr as per existing make and competable model, connecting necessary copper tubings by gas welding, gas charging with R-134 after dismentling/taking out existing unserviceable condenser unit and testing after completion to entire satisfaction of Engr-in-Charge and user unit suitable for DF Make- Blue Star/LG /Voltas whichever applicable. Note: (i) Gas charging shall be measured and paid separately under appropriate item of this schedule. |
| 150 | M&L for refrigerant gas charging for Deep freezer with R-134A gas after proper cleaning of pipe lines with carbon tetra chloride and flushing with Nitrogen, complete leakage test, including replacement of liquide line filter, capillary tube, required soldering/brazing/gas welding to attaing proper cooling level to entire satisfaction of Engr-in-Charge and User unit for 200/310L deep freezer Unit. |
| 151 | M&L for refrigerant gas charging for Refrigerator with R-134A gas after proper cleaning of pipe lines with carbon tetra chloride and flushing with Nitrogen, complete leakage test, including replacement of liquide line filter, capillary tube, required soldering/brazing/gas welding to attaing proper cooling level to entire satisfaction of Engr-in-Charge and User unit for 190 L to 321 L Refrigerator Unit. |
| 152 | Taking out old unsv and Supply and Fixing Voltage Stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of +- 2.5% and of capacity 2 KVA complete all as specified and directed. Make : V GUARD/APLAB/ANDREW YULE/AE |
| 153 | Servicing of window/ split type AC 1.5/2TR TR capacity any make including cleaning the condensing and evaporative coil with the help of descaling solution & water, greasing and oiling the blower motor and refixing the same in position after servicing complete all as specified and directed by Engineer-in-charge. |
| 154 | M&L in replacement of starting relay suitable for 1.5/2 TR capacity window/ split type AC including connections all as specified and directed by Engineer-in-Charge. Make: SHRI RAM/ RENUTROI/ KELTRON. |
| 155 | M&L in replacement of starting capacitor 80-100 mfdsuitable for 1.5/2 TR window/ split type AC all as specified and directed by Engineer-in-Charge. Make: EPCOS/ SARDA/ TESLA/ASIAN. |
| 156 | M&L in replacement of Air Filter pad suitable for window type AC 1.5/2 TR capacity all as specified and directed by Engineer-in-Charge. |
| 157 | M&L in replacement overload protector suitable for 1.5/2 TR window/ split type AC including connections all as specified and directed by Engineer-in-Charge. Make: SRIRAM/ RANUTRAL/ KELTRON. |
| 158 | M&L in replacement of running capacitor 36/ 45 mfdsuitable for 1.5/2 TR capacitywindow/ split type AC all as specified and directed by Engineer-in-Charge. Make: EPCOS/TESLA/SARDA/ASIAN. |
| 159 | M&L in replacement of selector switch/ Knob suitable for window type AC 1.5/2 TR capacity all as specified and directed by Engineer-in-Charge.Make: AGI/UNIQUE. |
| 160 | M&L for disconnecting and taking down of blower motor suitableforwindow typeAC 1.5/ 2 TR capacity , rewinding with super enameled copper including wire as existing gauge including replacement of bushes and refixing the same complete all as specified and directed by Engineer-in-Charge. |
| 161 | All as per Srl item No 139.00 above butsuitable for 1.5/ 2 TR capacity spilt type AC. |
| 162 | Supply and charging of R-22/ R-134a as existing refrigerant in window/ split type AC 1.5/2 TR capacity including cleaning the Gas system with anticorrosive solution and charging the refrigerant with anti most substances, strainer and rectification of leakage and replacement of filter and copper capillary complete all as specified and directedby Engineer-in-Charge. |
| 163 | Dismantling of old unserviceable sealed compressor of 1.5/2 TR capacity window type AC andS&F new sealed compressor including soldering of copper pipe, cleaning the refrigerant system, rectification of leakage, charging of refrigerant, rubber pads for foundation, nut & bolts etc and Testing the compressor all as specified and directed by Engineer-in-Charge. Make:Kirlosker/Tecumesh |
| 164 | All as per item No.142.00 above but suitable for 1.5/ 2 TR capacity split type AC. Make: Kirlosker/Tecumesh |
| 165 | M&L for Painting of bottom tray of window typeAC ofany capacity with black Japan anti Corrosive paint in side and out side complete all as specified and directed by Engineer-in-Charge. |
| 166 | M&L for Writing of MES No/SM No/Make Srl No on window type AC/Water Cooler/refrigerator/ Deep freezer with white synthetic enamel paid 2” high all as specified and directed by Engineer-in-Charge. |
| 167 | Amount of credit of Rs. 360510.50 for retrived old material as mentioned in Schedule \"A\" section-II of tender document in pdf form, will be deducted offline while acceptence of tender. |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy