Up-Gradation Renovation Restoration Of Street Lights High Mast Lights At Nathatop Bus Stand Meadow At Sanasar Sudhmahadev Mantalai Gourikund Latti Dudu Kimchi Samroli Shivgalii Kassalghoom Road Dogra Kud And Dalsar U
Tender Value
33.46 Lakhs
Estimated cost
Bid Submission
30 Jun 2022
0 days left
EMD
66920
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Udhampur → Jammu And Kashmir
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Up-Gradation Renovation Restoration Of Street Lights High Mast Lights At Nathatop Bus Stand Meadow At Sanasar Sudhmahadev Mantalai Gourikund Latti Dudu Kimchi Samroli Shivgalii Kassalghoom Road Dogra Kud And Dalsar U
BOQ
| Sl. No. | Item Description |
| 1 | D (KASSALGHOOM MOR TO NAGMANDIR Supply, laying (75 Cm below ground level including excavation and refilling the trench), testing and commissioning of 10 sqmm 4 core XLPE/PVC insulated (heavy duty) armoured electric cable with aluminium conductor for working voltage upto 1100v. (Make havels, polycab,kei) |
| 2 | Providing installation, testing and commissioning of outdoor type, cubical feeder panel with 1.6 mm thick sheet MS/CRS sheet painted from inside and outside to provide complete protection from water moisture, dust and vermin proof, duly wired up with the following accessories/equipment.a)MCCB FP 100 amp 1 nos (Make-L&T/ABB/Siemens)b)Contactor 50 amp 1 nos(Make L&T/ABB/Siemens)c)Digital Timer 1 nos.(Reputed make)d)Voltmeter 1nos.e) Selector switch 1nos.f)Indicators R,Y,B. g)Busbar and fittings. |
| 3 | Supply, installation, testing and commissioning of 5 meter Octagonal pole of 3mm thicknesshaving top dia 70 mm and bottom dia 130 mm and base plate size of 200x200x12 and suitable foundation bolts with single arm bracket of 1 mtrMake-Bajaj/Valmount/Philips. |
| 4 | Supplyingand fixing 5 amp to 32 amp rating 240/415 volts 10 KA, “ C” curve, miniature circuit breaker suitable for inductive load of following pole in existing MCBDB complete with connection, testing and commissioning etc as required.(Make: Havels/ABB/Schneider/Siemens) |
| 5 | a) Single pole. |
| 6 | Supply, laying, testing and commissioning of 2.5 sqmm cu wire.(Make-polycab, anchor, havels). |
| 7 | Supply, installation, testing and commissioning of connector FP 63 amp. |
| 8 | SITC of high quality integrated LED street light with a minimum system lumen of 9900 Lm and system wattage 90W with a nominal efficiency 110 lumen/watt. CCT of 5700k with SDCM of < 5 and CRI >70. The housing should be of non-corrosive high pressure die-cast aluminium with heat resistant toughened clear glass to with stand extreme environments with PF >0.95. Lifetime of 50k hours @L70. The Ingress protection should be minimum IP 66 with an IK rating of 07. The Luminaire should have SKV internal 10kv external surge protection in the Luminaire. Manufacturer shall have in house lab approved by NABL or ministry of science of govt. of India. LM 79 and Lm 80 report need to be submitted from a NABL/UL accredited lab to verify above parameters. Make,Philips/Bajaj/Wipro. |
| 9 | Supply, installation testing and compressing of aluminium lugs/aluminium thimble complete job. |
| 10 | Supplying installation testing and commissioning of lockable junction box complete job. |
| 11 | Earth work in bulkexcavation by manual means over areas(exceeding 30 cm in depth, 1.5 m in width as well as 10 m2 on plan)including disposal of excavated earth lead upto 50 meters and lift upto 1.5 m, as directed by engineer-in-charge(All kinds of soil)spec. .9x0.45x0.45=0.182 cum x14 =2.54 cum ( including panel concreting 2nos) |
| 12 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centering, shuttering. All work upto plinth level 1:2:4( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) spec. .9x0.45x0.45=2.54 cum x78 =2.54 cum |
| 13 | Centering shuttering including strutting, propping etc. and removal of form work for retaining wall, return walls, walls (any thickness) including attached pilaster buttresses, plinth and string course fillets, kerbs and steps etc0 .3x0.3x4=0.36 x78=5.04 sqm |
| 14 | Carriage of stone aggregate by mechanical transport including loading, unloading and stacking on an average distance of 26km qty vide item no 12 [email protected] |
| 15 | Carriage of sand by mechanical transport including loading, unloading and stacking on an average distance of 26km qty vide item no 12 [email protected] |
| 16 | Carriage of cement by mechanical transport including loading, unloading and stacking on an average distance of 26km qty vide item no 12 [email protected] |
| 17 | Engaging of electrician and khallasi by way of disconnecting the main supply of Non functionallights, open the damagedfittings,poles arms,lights and refitted the same complete job |
| 18 | a)Electrician |
| 19 | b) Khallasi |
| 20 | Engaging of electrician and khallasi by way of disconnecting the main supply of Non functionallights, open the damagedfittings, junction boxandchecking each part/spare one by one and after complete work refitting the all accessories and other allied works.(pipe poles 18 no) |
| 21 | a)electrician |
| 22 | b) khallasi |
| 23 | E (REPARING OF HIGH MAST POLE WITH IN JURIDUCTION OF PDA Sudhmahadev ( 2no) Mantali (1 no), DUDU (1no) panama chowk Kud (1 no),LATTI ( 3 no) SERA MORH (1no) KUD (1no) PATNITOP (8 NO).SANASAR (4 N0) Gorikund (2 no)SAMROLI (3N0) |
| 24 | Supply, laying, testing and commissioning of 10 sqmm 2 core XLPE/PVC insulated (heavy duty) armoured electric cable with aluminium conductor for working voltage upto 1100v. (Make havels, polycab,kei) |
| 25 | Supply, installation, testing and commissioning of LED Flood lights, Matt black textured powder coated pressure die cast with aluminium housing & frame with heat resistant toughened clear glass fixed with SS screw. Anti Dust Exposed lens, sturdiness and embossed brand name/logo name of manufacturer on fixture. The fixture should have a minimum system efficacy of 120 lumen/watt and a minimum system lemen output of 14400 lumens and maximum system wattage of 120 watts. The fixture shall have a CRI of minimum 70. The fixture shall be designed for a system life of 50,000 hours @ 70% lumen maintenance. Ingress protection of IP66 (lamp and gear compartment) and Mechanical impact Resistance Rating of IK >=07. The fixture driver should have an operating voltage range of 120-277 v, surge protection of internal 4KV and extral surge protection of 10KV, PF >0.95, THD<10%. Manufacturer shall have in house lab approved by NABL or ministry of science of govt. of India. LM 79 and LM 80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters. (Make Bajaj/Wipro/Philips,). |
| 26 | Providing installation, testing and commissioning of outdoor type, cubical feeder panel with 1.6 mm thick sheet MS/CRS sheet painted from inside and outside to provide complete protection from water moisture, dust and vermin proof, duly wired up with the following accessories/equipment.a)MCCB FP 100 amp 1 nos (Make-L&T/ABB/Siemens)b)Contactor 50 amp 1 nos(Make L&T/ABB/Siemens)c) digital Timer 1 nos.(Reputed make)d)Voltmeter 1nos.e) Selector switch 1nos.f)Indicators R,Y,B.g)Busbar and fittings.Installation with concrete ratio 1:2:4 |
| 27 | Repairs LT outdoor panel by ways of removing damaged parts and fitting ofa)MCB 240/415v, 6A=04 no’sb)1.5 sq mm insulated copper wire = 160mtrc)MCB DP =32A =01 NO’Sd)Terminals for incoming and outgoing linee)Time switch for automatic operation luminaries=01 no’s(digital timer)f) Welding to damaged panel door and fabrication of new door hinges and locking arrangement.g)Painting of enamel in and outside surfaces by ready mixed synthetic enamel paints 02 coats after cleaning, removing all rust formation on panel by scrubbing and sanding the rough surfaces. |
| 28 | Supply, laying, testing and commissioning of 2.5 sqmm cu wire.(Make-polycab, anchor, havels). |
| 29 | Supply, installation testing and compressing of aluminium lugs/aluminium thimble complete job. |
| 30 | Engaging of electrician and khallasi by way of disconnecting the main supply of Non functionallights, open the damagedfittings,poles arms,lights complete job(28 no) |
| 31 | a)Electrician |
| 32 | b) Khallasi |
| 33 | F ( KUD MAIN MARKET ,SUKETAR MANDIR TO BABA CHUTHO,SERI CULTURE OFFICE TO PRIMARY SCHOOL,KUD MARKET TO MASJID, KUD MARKET TO PANCHAYAT GAR AREA) |
| 34 | Supply, laying, testing and commissioning of 10 sqmm 4 core XLPE/PVC insulated (heavy duty) armoured electric cable with aluminium conductor for working voltage upto 1100v. (Make havels, polycab,kei) |
| 35 | Supply, laying, (75 Cm below ground level including excavation and refilling the trench) testing and commissioning of 10 sqmm 2 core XLPE/PVC insulated (heavy duty) armoured electric cable with aluminium conductor for working voltage upto 1100v. (Make havels, polycab,kei) |
| 36 | Providing installation, testing and commissioning of outdoor type, cubical feeder panel with 1.6 mm thick sheet MS/CRS sheet painted from inside and outside to provide complete protection from water moisture, dust and vermin proof, duly wired up with the following accessories/equipment.a)MCCB FP 100 amp 1 nos (Make-L&T/ABB/Siemens)b)Contactor 50 amp 1 nos(Make L&T/ABB/Siemens)c)Digital Timer 1 nos.(Reputed make)d)Voltmeter 1nos.e) Selector switch 1nos.f)Indicators R,Y,B.g)Busbar and fittings. |
| 37 | Supply, installation, testing and commissioning of 5 meter Octagonal pole of 3mm thicknesshaving top dia 70 mm and bottom dia 130 mm and base plate size of 200x200x12 and suitable foundation bolts with single arm bracket of 1 mtrMake-Bajaj/Valmount/Philips. |
| 38 | Supplyingand fixing 5 amp to 32 amp rating 240/415 volts 10 KA, “ C” curve, miniature circuit breaker suitable for inductive load of following pole in existing MCBDB complete with connection, testing and commissioning etc as required.(Make: Havels/ABB/Schneider/Siemens) |
| 39 | a) Single pole. |
| 40 | Supply, laying, testing and commissioning of 2.5 sqmm cu wire.(Make-polycab, anchor, havels). |
| 41 | Supply, installation, testing and commissioning of connector FP 63 amp. |
| 42 | SITC of high quality integrated LED street light with a minimum system lumen of 9900 Lm and system wattage 90W with a nominal efficiency 110 lumen/watt. CCT of 5700k with SDCM of < 5 and CRI >70. The housing should be of non-corrosive high pressure die-cast aluminium with heat resistant toughened clear glass to with stand extreme environments with PF >0.95. Lifetime of 50k hours @L70. The Ingress protection should be minimum IP 66 with an IK rating of 07. The Luminaire should have SKV internal 10kv external surge protection in the Luminaire. Manufacturer shall have in house lab approved by NABL or ministry of science of govt. of India. LM 79 and Lm 80 report need to be submitted from a NABL/UL accredited lab to verify above parameters. Make,Philips/Bajaj/Wipro. |
| 43 | Supply, installation testing and compressing of aluminium lugs/aluminium thimble complete job. |
| 44 | Supplying installation testing and commissioning of lockable junction box complete job. |
| 45 | Earth work in bulkexcavation by manual means over areas(exceeding 30 cm in depth, 1.5 m in width as well as 10 m2 on plan)including disposal of excavated earth lead upto 50 meters and lift upto 1.5 m, as directed by engineer-in-charge(All kinds of soil)spec. .9x0.45x0.45=0.182 cum x12 =2-184 cum ( including panel)for pole |
| 46 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centering, shuttering. All work upto plinth level 1:2:4( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) spec. .9x0.45x0.45=0.182 cum x12 =2.184 cumfor pole |
| 47 | Centering shuttering including strutting, propping etc. and removal of form work for retaining wall, return walls, walls (any thickness) including attached pilaster buttresses, plinth and string course fillets, kerbs and steps etc 0 .3x0.3x4=0.36 x12= 4.32 sqm for octagonal pole |
| 48 | Carriage of stone aggregate by mechanical transport including loading, unloading and stacking on an average distance of 15km qty vide item no 12 [email protected] for octagonal pole |
| 49 | Carriage of sand by mechanical transport including loading, unloading and stacking on an average distance of 15km qty vide item no 12 [email protected] for octagonal pole |
| 50 | Carriage of cement by mechanical transport including loading, unloading and stacking on an average distance of 15km qty vide item no 12 [email protected] for octagonal pole |
| 51 | Engaging of electrician and khallasi by way of disconnecting the main supply of Non functionallights, open the damagedfittings,poles arms,lights and refitted the same complete job |
| 52 | a)Electrician |
| 53 | b) Khallasi |
| 54 | Engaging of electrician and khallasi by way of disconnecting the main supply of Non functionallights, open the damagedfittings, junction boxandchecking each part/spare one by one and after complete work refitting the all accessories and other allied works.(pipe poles 36 no) |
| 55 | a)Electrician |
| 56 | b) Khallasi |
| 57 | Engaging of khallasiby way of opening the nut and bolt, junction box and plate dismantling the pipe pole from concrete and other allied works.. (36 no pipe poles) |
| 58 | Khallsi |
| 59 | Earth work in bulkexcavation by manual means over areas(exceeding 30 cm in depth, 1.5 m in width as well as 10 m2 on plan)including disposal of excavated earth lead upto 50 meters and lift upto 1.5 m, as directed by engineer-in-charge(All kinds of soil) 0.6x0.6x0.45x36no=5.83cum( for pipe poles) |
| 60 | Providing and laying cement concrete in retaining wall,return wall, walls (any thickness) including attached pilasters,coloumns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parpets, coping, bed blocks, anchors block, plain window sills, fillets or lacing etc floor V level, incliding curring but eccluding the cost of centring, shuttering and finishing with1:3:6( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size ) spec. 0.6x0.45x0.45x36no=5.83cum( for pipe poles) |
| 61 | Centering shuttering including strutting, propping etc. and removal of form work for retaining wall, return walls, walls (any thickness) including attached pilaster buttresses, plinth and string course fillets, kerbs and steps etc0 .3x0.3x4x0.36nos0.36 x36 no poles=12.96sqm( for pipe poles) |
| 62 | Carriage of stone aggregate by mechanical transport including loading, unloading and stacking on an average distance of 26km qty vide item no 21 [email protected]( for pipe poles) |
| 63 | Carriageof sand by mechanical transport including loading, unloading and stacking on an average distance of 26km qty vide item no 21 [email protected]( for pipe poles) |
| 64 | Carriage of cement by mechanical transport including loading, unloading and stacking on an average distance of 26km qty vide item no 21 [email protected]( for pipe poles) |
| 65 | Engaging of welder for welding of pipes poles, junction box and other allied works. A) welder |
| 66 | Providing and fixing of Goloves in place of damaged one. |
| 67 | Providind and fixing of LED blub 20 watt in place of damaged one.(make everyday,Crompton,anchor,havels) |
| 68 | Providing , fixing and assemblingGI pipe ( 2 no pipe poles) (50mm dia)with welding, fitting complete job |
| 69 | Painting of street light pipe poles two coats of green paints ( 18 no pipe poles).(Make- narolec/asian paints) |
AI Tender Summary
Tender Timeline
Jun 11, 2022
11:30 IST
Tender Published
Tender notice published.
CompletedJun 30, 2022
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedJul 01, 2022
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender