Public Administrative Department Local Bodies Closing in 0 days TDR #32623679

Up-Gradation Renovation Restoration Of Street Lights High Mast Lights At Nathatop Bus Stand Meadow At Sanasar Sudhmahadev Mantalai Gourikund Latti Dudu Kimchi Samroli Shivgalii Kassalghoom Road Dogra Kud And Dalsar U

Issued by Local Bodies · Udhampur, Jammu And Kashmir
Tender Value
33.46 Lakhs
Estimated cost
Bid Submission
30 Jun 2022
0 days left
EMD
66920
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Udhampur → Jammu And Kashmir
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Up-Gradation Renovation Restoration Of Street Lights High Mast Lights At Nathatop Bus Stand Meadow At Sanasar Sudhmahadev Mantalai Gourikund Latti Dudu Kimchi Samroli Shivgalii Kassalghoom Road Dogra Kud And Dalsar U

BOQ

Name of Work:-Up-gradation, Renovation, Restoration of Street Lights, High Mast Lights at Nathatop Bus Stand, Meadow at Sanasar, Sudhmahadev, Mantalai, Gourikund, Latti, Dudu, Kimchi, Samroli, Shivgalii, Kassalghoom Road, Dogra, Kud and Dalsar.
Sl. No. Item Description
1D (KASSALGHOOM MOR TO NAGMANDIR Supply, laying (75 Cm below ground level including excavation and refilling the trench), testing and commissioning of 10 sqmm 4 core XLPE/PVC insulated (heavy duty) armoured electric cable with aluminium conductor for working voltage upto 1100v. (Make havels, polycab,kei)
2Providing installation, testing and commissioning of outdoor type, cubical feeder panel with 1.6 mm thick sheet MS/CRS sheet painted from inside and outside to provide complete protection from water moisture, dust and vermin proof, duly wired up with the following accessories/equipment.a)MCCB FP 100 amp 1 nos (Make-L&T/ABB/Siemens)b)Contactor 50 amp 1 nos(Make L&T/ABB/Siemens)c)Digital Timer 1 nos.(Reputed make)d)Voltmeter 1nos.e) Selector switch 1nos.f)Indicators R,Y,B. g)Busbar and fittings.
3Supply, installation, testing and commissioning of 5 meter Octagonal pole of 3mm thicknesshaving top dia 70 mm and bottom dia 130 mm and base plate size of 200x200x12 and suitable foundation bolts with single arm bracket of 1 mtrMake-Bajaj/Valmount/Philips.
4Supplyingand fixing 5 amp to 32 amp rating 240/415 volts 10 KA, “ C” curve, miniature circuit breaker suitable for inductive load of following pole in existing MCBDB complete with connection, testing and commissioning etc as required.(Make: Havels/ABB/Schneider/Siemens)
5a) Single pole.
6Supply, laying, testing and commissioning of 2.5 sqmm cu wire.(Make-polycab, anchor, havels).
7Supply, installation, testing and commissioning of connector FP 63 amp.
8SITC of high quality integrated LED street light with a minimum system lumen of 9900 Lm and system wattage 90W with a nominal efficiency 110 lumen/watt. CCT of 5700k with SDCM of < 5 and CRI >70. The housing should be of non-corrosive high pressure die-cast aluminium with heat resistant toughened clear glass to with stand extreme environments with PF >0.95. Lifetime of 50k hours @L70. The Ingress protection should be minimum IP 66 with an IK rating of 07. The Luminaire should have SKV internal 10kv external surge protection in the Luminaire. Manufacturer shall have in house lab approved by NABL or ministry of science of govt. of India. LM 79 and Lm 80 report need to be submitted from a NABL/UL accredited lab to verify above parameters. Make,Philips/Bajaj/Wipro.
9Supply, installation testing and compressing of aluminium lugs/aluminium thimble complete job.
10Supplying installation testing and commissioning of lockable junction box complete job.
11Earth work in bulkexcavation by manual means over areas(exceeding 30 cm in depth, 1.5 m in width as well as 10 m2 on plan)including disposal of excavated earth lead upto 50 meters and lift upto 1.5 m, as directed by engineer-in-charge(All kinds of soil)spec. .9x0.45x0.45=0.182 cum x14 =2.54 cum ( including panel concreting 2nos)
12Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centering, shuttering. All work upto plinth level 1:2:4( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) spec. .9x0.45x0.45=2.54 cum x78 =2.54 cum
13Centering shuttering including strutting, propping etc. and removal of form work for retaining wall, return walls, walls (any thickness) including attached pilaster buttresses, plinth and string course fillets, kerbs and steps etc0 .3x0.3x4=0.36 x78=5.04 sqm
14Carriage of stone aggregate by mechanical transport including loading, unloading and stacking on an average distance of 26km qty vide item no 12 [email protected]
15Carriage of sand by mechanical transport including loading, unloading and stacking on an average distance of 26km qty vide item no 12 [email protected]
16Carriage of cement by mechanical transport including loading, unloading and stacking on an average distance of 26km qty vide item no 12 [email protected]
17Engaging of electrician and khallasi by way of disconnecting the main supply of Non functionallights, open the damagedfittings,poles arms,lights and refitted the same complete job
18a)Electrician
19b) Khallasi
20Engaging of electrician and khallasi by way of disconnecting the main supply of Non functionallights, open the damagedfittings, junction boxandchecking each part/spare one by one and after complete work refitting the all accessories and other allied works.(pipe poles 18 no)
21a)electrician
22b) khallasi
23E (REPARING OF HIGH MAST POLE WITH IN JURIDUCTION OF PDA Sudhmahadev ( 2no) Mantali (1 no), DUDU (1no) panama chowk Kud (1 no),LATTI ( 3 no) SERA MORH (1no) KUD (1no) PATNITOP (8 NO).SANASAR (4 N0) Gorikund (2 no)SAMROLI (3N0)
24Supply, laying, testing and commissioning of 10 sqmm 2 core XLPE/PVC insulated (heavy duty) armoured electric cable with aluminium conductor for working voltage upto 1100v. (Make havels, polycab,kei)
25Supply, installation, testing and commissioning of LED Flood lights, Matt black textured powder coated pressure die cast with aluminium housing & frame with heat resistant toughened clear glass fixed with SS screw. Anti Dust Exposed lens, sturdiness and embossed brand name/logo name of manufacturer on fixture. The fixture should have a minimum system efficacy of 120 lumen/watt and a minimum system lemen output of 14400 lumens and maximum system wattage of 120 watts. The fixture shall have a CRI of minimum 70. The fixture shall be designed for a system life of 50,000 hours @ 70% lumen maintenance. Ingress protection of IP66 (lamp and gear compartment) and Mechanical impact Resistance Rating of IK >=07. The fixture driver should have an operating voltage range of 120-277 v, surge protection of internal 4KV and extral surge protection of 10KV, PF >0.95, THD<10%. Manufacturer shall have in house lab approved by NABL or ministry of science of govt. of India. LM 79 and LM 80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters. (Make Bajaj/Wipro/Philips,).
26Providing installation, testing and commissioning of outdoor type, cubical feeder panel with 1.6 mm thick sheet MS/CRS sheet painted from inside and outside to provide complete protection from water moisture, dust and vermin proof, duly wired up with the following accessories/equipment.a)MCCB FP 100 amp 1 nos (Make-L&T/ABB/Siemens)b)Contactor 50 amp 1 nos(Make L&T/ABB/Siemens)c) digital Timer 1 nos.(Reputed make)d)Voltmeter 1nos.e) Selector switch 1nos.f)Indicators R,Y,B.g)Busbar and fittings.Installation with concrete ratio 1:2:4
27Repairs LT outdoor panel by ways of removing damaged parts and fitting ofa)MCB 240/415v, 6A=04 no’sb)1.5 sq mm insulated copper wire = 160mtrc)MCB DP =32A =01 NO’Sd)Terminals for incoming and outgoing linee)Time switch for automatic operation luminaries=01 no’s(digital timer)f) Welding to damaged panel door and fabrication of new door hinges and locking arrangement.g)Painting of enamel in and outside surfaces by ready mixed synthetic enamel paints 02 coats after cleaning, removing all rust formation on panel by scrubbing and sanding the rough surfaces.
28Supply, laying, testing and commissioning of 2.5 sqmm cu wire.(Make-polycab, anchor, havels).
29Supply, installation testing and compressing of aluminium lugs/aluminium thimble complete job.
30Engaging of electrician and khallasi by way of disconnecting the main supply of Non functionallights, open the damagedfittings,poles arms,lights complete job(28 no)
31a)Electrician
32b) Khallasi
33F ( KUD MAIN MARKET ,SUKETAR MANDIR TO BABA CHUTHO,SERI CULTURE OFFICE TO PRIMARY SCHOOL,KUD MARKET TO MASJID, KUD MARKET TO PANCHAYAT GAR AREA)
34Supply, laying, testing and commissioning of 10 sqmm 4 core XLPE/PVC insulated (heavy duty) armoured electric cable with aluminium conductor for working voltage upto 1100v. (Make havels, polycab,kei)
35Supply, laying, (75 Cm below ground level including excavation and refilling the trench) testing and commissioning of 10 sqmm 2 core XLPE/PVC insulated (heavy duty) armoured electric cable with aluminium conductor for working voltage upto 1100v. (Make havels, polycab,kei)
36Providing installation, testing and commissioning of outdoor type, cubical feeder panel with 1.6 mm thick sheet MS/CRS sheet painted from inside and outside to provide complete protection from water moisture, dust and vermin proof, duly wired up with the following accessories/equipment.a)MCCB FP 100 amp 1 nos (Make-L&T/ABB/Siemens)b)Contactor 50 amp 1 nos(Make L&T/ABB/Siemens)c)Digital Timer 1 nos.(Reputed make)d)Voltmeter 1nos.e) Selector switch 1nos.f)Indicators R,Y,B.g)Busbar and fittings.
37Supply, installation, testing and commissioning of 5 meter Octagonal pole of 3mm thicknesshaving top dia 70 mm and bottom dia 130 mm and base plate size of 200x200x12 and suitable foundation bolts with single arm bracket of 1 mtrMake-Bajaj/Valmount/Philips.
38Supplyingand fixing 5 amp to 32 amp rating 240/415 volts 10 KA, “ C” curve, miniature circuit breaker suitable for inductive load of following pole in existing MCBDB complete with connection, testing and commissioning etc as required.(Make: Havels/ABB/Schneider/Siemens)
39a) Single pole.
40Supply, laying, testing and commissioning of 2.5 sqmm cu wire.(Make-polycab, anchor, havels).
41Supply, installation, testing and commissioning of connector FP 63 amp.
42SITC of high quality integrated LED street light with a minimum system lumen of 9900 Lm and system wattage 90W with a nominal efficiency 110 lumen/watt. CCT of 5700k with SDCM of < 5 and CRI >70. The housing should be of non-corrosive high pressure die-cast aluminium with heat resistant toughened clear glass to with stand extreme environments with PF >0.95. Lifetime of 50k hours @L70. The Ingress protection should be minimum IP 66 with an IK rating of 07. The Luminaire should have SKV internal 10kv external surge protection in the Luminaire. Manufacturer shall have in house lab approved by NABL or ministry of science of govt. of India. LM 79 and Lm 80 report need to be submitted from a NABL/UL accredited lab to verify above parameters. Make,Philips/Bajaj/Wipro.
43Supply, installation testing and compressing of aluminium lugs/aluminium thimble complete job.
44Supplying installation testing and commissioning of lockable junction box complete job.
45Earth work in bulkexcavation by manual means over areas(exceeding 30 cm in depth, 1.5 m in width as well as 10 m2 on plan)including disposal of excavated earth lead upto 50 meters and lift upto 1.5 m, as directed by engineer-in-charge(All kinds of soil)spec. .9x0.45x0.45=0.182 cum x12 =2-184 cum ( including panel)for pole
46Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centering, shuttering. All work upto plinth level 1:2:4( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) spec. .9x0.45x0.45=0.182 cum x12 =2.184 cumfor pole
47Centering shuttering including strutting, propping etc. and removal of form work for retaining wall, return walls, walls (any thickness) including attached pilaster buttresses, plinth and string course fillets, kerbs and steps etc 0 .3x0.3x4=0.36 x12= 4.32 sqm for octagonal pole
48Carriage of stone aggregate by mechanical transport including loading, unloading and stacking on an average distance of 15km qty vide item no 12 [email protected] for octagonal pole
49Carriage of sand by mechanical transport including loading, unloading and stacking on an average distance of 15km qty vide item no 12 [email protected] for octagonal pole
50Carriage of cement by mechanical transport including loading, unloading and stacking on an average distance of 15km qty vide item no 12 [email protected] for octagonal pole
51Engaging of electrician and khallasi by way of disconnecting the main supply of Non functionallights, open the damagedfittings,poles arms,lights and refitted the same complete job
52a)Electrician
53b) Khallasi
54Engaging of electrician and khallasi by way of disconnecting the main supply of Non functionallights, open the damagedfittings, junction boxandchecking each part/spare one by one and after complete work refitting the all accessories and other allied works.(pipe poles 36 no)
55a)Electrician
56b) Khallasi
57Engaging of khallasiby way of opening the nut and bolt, junction box and plate dismantling the pipe pole from concrete and other allied works.. (36 no pipe poles)
58Khallsi
59Earth work in bulkexcavation by manual means over areas(exceeding 30 cm in depth, 1.5 m in width as well as 10 m2 on plan)including disposal of excavated earth lead upto 50 meters and lift upto 1.5 m, as directed by engineer-in-charge(All kinds of soil) 0.6x0.6x0.45x36no=5.83cum( for pipe poles)
60Providing and laying cement concrete in retaining wall,return wall, walls (any thickness) including attached pilasters,coloumns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parpets, coping, bed blocks, anchors block, plain window sills, fillets or lacing etc floor V level, incliding curring but eccluding the cost of centring, shuttering and finishing with1:3:6( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size ) spec. 0.6x0.45x0.45x36no=5.83cum( for pipe poles)
61Centering shuttering including strutting, propping etc. and removal of form work for retaining wall, return walls, walls (any thickness) including attached pilaster buttresses, plinth and string course fillets, kerbs and steps etc0 .3x0.3x4x0.36nos0.36 x36 no poles=12.96sqm( for pipe poles)
62Carriage of stone aggregate by mechanical transport including loading, unloading and stacking on an average distance of 26km qty vide item no 21 [email protected]( for pipe poles)
63Carriageof sand by mechanical transport including loading, unloading and stacking on an average distance of 26km qty vide item no 21 [email protected]( for pipe poles)
64Carriage of cement by mechanical transport including loading, unloading and stacking on an average distance of 26km qty vide item no 21 [email protected]( for pipe poles)
65Engaging of welder for welding of pipes poles, junction box and other allied works. A) welder
66Providing and fixing of Goloves in place of damaged one.
67Providind and fixing of LED blub 20 watt in place of damaged one.(make everyday,Crompton,anchor,havels)
68Providing , fixing and assemblingGI pipe ( 2 no pipe poles) (50mm dia)with welding, fitting complete job
69Painting of street light pipe poles two coats of green paints ( 18 no pipe poles).(Make- narolec/asian paints)

AI Tender Summary

OUR REF NO 32623679
AUTHORITY Local Bodies
TENDER VALUE 33.46 Lakhs
LAST DATE 30-06-2022
Authority
Authority Name Patnitop Development Authortiy Limited
Work Description Up-Gradation Renovation Restoration Of Street Lights High Mast Lights At Nathatop Bus Stand Meadow At Sanasar Sudhmahadev Mantalai Gourikund Latti Dudu Kimchi Samroli Shivgalii Kassalghoom Road Dogra Kud And Dalsar U
Basic Detail
Tender No 27 of 2022-23
Bidding Type Tender
Location
City Udhampur
State Jammu And Kashmir
Key Dates
Publish Date 11 Jun 2022
Submission Date 30 Jun 2022
Open Date 01 Jul 2022
Finance
Tender Value 33.46 Lakhs
Tender Fee 1000
EMD 66920
Exemption Not Available
Document List
8e8ae146-1e59-451e-8d8d-dd4e48e24274.html
BOQ_411420.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jun 11, 2022
11:30 IST

Tender Published

Tender notice published.

Completed
Jun 30, 2022
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Jul 01, 2022

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

8e8ae146-1e59-451e-8d8d-dd4e48e24274.html

xls

BOQ_411420.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders