Supply And Installation Work Of Air Conditioner At Room Number 11 And Nirman Shakha In Main Office Of Nagar Nigam Bikaner. , Supply , Installation, Testing And Comissioning Of Iso Certified Company Made Air Cooled Hi Wall Split Type Air Conditioners W, bikaner-Rajasthan

Department Of Local Bodies has published Supply And Installation Work Of Air Conditioner At Room Number 11 And Nirman Shakha In Main Office Of Nagar Nigam Bikaner. , Supply , Installation, Testing And Comissioning Of Iso Certified Company Made Air Cooled Hi Wall Split Type Air Conditioners W. Submission Date for this Tender is 13-06-2022. Electrical Maintenance Tenders in bikaner Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

32614529
Supply And Installation Work Of Air Conditioner At Room Number 11 And Nirman Shakha In Main Office Of Nagar Nigam Bikaner. , Supply , Installation, Testing And Comissioning Of Iso Certified Company Made Air Cooled Hi Wall Split Type Air Conditioners W
Open Tender
Indian
Rajasthan
bikaner
13-06-2022

Tender Details

Supply And Installation Work Of Air Conditioner At Room Number 11 And Nirman Shakha In Main Office Of Nagar Nigam Bikaner. , Supply , Installation, Testing And Comissioning Of Iso Certified Company Made Air Cooled Hi Wall Split Type Air Conditioners With Latest Star Rating System As Per Bee Amended Upto Date Complete With Indoor Unit ( Idu ) , Out Door Unit ( Odu ) , Surface / Concealed Copper Refrigerant Piping With Insulation ( Closed Cell Elastomeric Nitrile Rubber Tubular Pipe Section ) Upto 3 Mtr ( Idu To Odu ) , Copper Power Cable Upto 3.5 Mtr ( Idu To Odu ) , R-32 / R-410 / R-407 Green Refrigerant, Wireless Remote Control, Suitable For Working Between 180-260V With Low & High Voltage Cutoff And 50 Hz , 1 Phase Ac Supply Capable Of Performing Cooling, Dehumidification, Air Circulation Of Following Capacity With Scroll / Rotary Compressor. Min 5 Year Oem Warranty Both Compressor And Pcb. Nabl Accredeated As Per Is / Iso / Iec 17025 Standards / Cpri / Erda Lab Testing Reports As Per Is 1391 ( Part-2 ) 2018 With Oem Certificate Must Submitted To Engineer In Charge. All As Per Pre Approved By Engineer In Charge. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products / Work , Refer Annexure A Attached With This Bsr . Non Invertor Type 1.5 Tr With 3 Star Rating Of Bee ( Iseer Not Less Then 3.5 ) . , Supply & Fixing Of External Thermal Closed Cell Elastomeric Nitrile Rubber Insulation Material Fm / Ul Approved With High Water Vapor Diffusion Resistance And Low Thermal Conductivity Should Be Certified Class O In Fire Propagation As Per Bs 476 Part 6 In Form Of Tubular Insulation Between Each Set Of Indoor & Outdoor Units As Per Specificationsnitrile Including Cost Of Adhesive Complete As Per Specification And As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products / Work , Refer Annexure A Attached With This Bsr . 6Mm Thick Insulation And 16 Mm Internal Dia , Supply & Fixing Of Fr Pvc Insulated & Sheathed 3 Core Flexible Copper Conductor As Per Pwd Specification For Electrical Works Confirming To Is:694 And As Per Is 8130 : 2013 Of 1.1 Kv Grade .Wire Should Be Made From 99.99% Purity Copper, Class 5 Stranding In Acc. To Iec 60228 For Lower Watt Loss , Oxygen Free ( <10 Ppm ) For Less Chances Of Oxidization And Higher Silver Content For Gives Better Conductivity , Insulation Pvc Type A , Flame Retardant As Per Is 10810-53, Better Amperage Rating As Per Vde 0298 Part 4 Including Making Connection Etc. As Required. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Wires. All As Per Pre Approved By Engineer In Charge, Making Connections. For Additional Technical Parameters Of Products / Work , Refer Annexure A Attached With This Bsr .2.5 Sq.Mm , Supply, Fixing And Testing Of Following Capacity Iso Certified Company Made Wall Mounted Stabilizer Having Output Voltage Variation From 200 V To 250 V ( + / -5% ) With Input Voltage Variation From 170 V To 260 V, Time Delay Facility From 2 To 4 Minute And High Cutoff At 270 V With Providing Of 16 Amp Plug Top Making Connection Etc Complete In All Respect. Nabl Accredeated / Cpri / Erda Lab Testing Reports With Oem Certificate Must Submitted To Engineer Incharge. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products / Work , Refer Annexure A Attached With This Bsr .3 Kva , Dismentling Of Split Air Conditioner Of Any Capacity / Any Type Including Existing Indoor Unit & Outdoor Unit , Refrigerant Piping , Connecting Cables , Drain Pipe Etc. Including Shifting Of Dismentaled Material To Store Complete As Required , Supply & Fixing Ms Powder Coated Stand Suitable For 1.0 / 1.5 / 2.0 Tr Outdoor Type Of Split Ac. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products / Work , Refer Annexure A Attached With This Bsr . , Providing & Fixing Of Recessed / Surface Mounting Type Sheet Steel / Plastic Enclosure As Per Pwd Specification For Electrical Works Conforming To Iec 61439-3 Of Not Less Then 1.2 Mm Thick For Housing Mcb / Isolator With Din Rail Including , All As Per Pre Approved By Engineer In Charge, Making Connections, With Lugs, Repairs Etc. As Required.Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Test Reports Before Execution & All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products / Work , Refer Annexure A Attached With This Bsr . With Plastic Enclosure Two Way. , Providing & Fixing Of 240 / 415 V Ac Mcb With Positive Isolation Of Breaking Capacity Not Less Than 10 Ka ( B / C Tripping Characteristic As Per Type Of Load And Site Requirement ) 4Kv Impulse Withstand Voltage, As Per Pwd Specification For Electrical Works With Isi Marked Is 8828 ( 1996 ) / Conforming To Iec 60898-1 2002, Iec 60947-2, Low Watt Losses, Trip Free Mechanisum , Energy Limiting Of Class 3 As Per Iec, Minimum Phase Termination Capacity Of 35Sq.Mm. , Conductor Line Load Reversibility, Label Holding Facility , Ip 20 Contact Protection And Fitted With Existing Distribution Board / Sheets, Min. Operation 20, 000 Upto 32 A Rating And 10, 000 Upto 63 A, 5000 For 80 A Rating Including Making Connections, Testing Etc. As Required. . Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Test Reports Before Execution & All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products / Work , Refer Annexure A Attached With This Bsr . 6 A To 32 A Rating , Wiring Of 3 / 5 Pin 6 Amp. Light Plug Point As Per Pwd Specification For Electrical Works With Isi Marked 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Conductor 1.1 Kv Grade ( Is:694 ) And 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Earth Conductor 1.1 Kv Grade ( Is:694 ) On Surface Isi Marked ( Is:14927 P - Ii ) Upvc Casing Capping & Its Accessories Like Coupler, Inner, Outer, Elbow, Square Box, Tee, End Cap Etc., Recessed 18 Swg Suitable G. I. Box With Earth Terminal / Surface Upvc Box With Earth Terminal, 6 A Switch, 3 / 5 Pin 6 A Socket, 3.0 Mm Thick Isi Marked Phenolic Laminated Sheet ( Is : 2036 - 1995 ) , Al. Alloy / Cadmium Plated Iron Screws 20 Mm Cup Washers Etc.All As Per Pre Approved By Engineer In Charge, Making Connections, Testing Etc. Complete As Required. For Specification Of Copper Conductor, Phenolic Laminated Sheets & Electrical / Wiring Accessories Refer Chapter E - 04, E - 05 & E - 07 . For Additional Technical Parameters Of Products / Work , Refer Annexure A Attached With This Bsr . Short Point ( Up To 3 Mtr. ) , S&F Following Sizes Of Isi Marked ( Is:14927 P - Ii ) Upvc Casing Capping As Per Pwd Specification For Electrical Works Along With All Accessories Like Coupler, Inner, Outer, Elbow, Square Box, Tee, End Cap Etc. On Surface With Screws, Expansion Fasteners , All As Per Pre Approved By Engineer In Charge, Making Connections, Testing Etc. Complete As Required. For Additional Technical Parameters Of Products / Work , Refer Annexure A Attached With This Bsr . 25 Mm X 12 Mm , Supply , Installation, Testing And Comissioning Of Interconnecting Refrigerant Copper Pipe For Split Of Dhe Grade C12200- Astm B68, B75, Chemical Composition Of Copper %- 99.0 Min And Phosphorus %- 0.015 To 0.040 . For Annealed Copper Tube :- Tensile Strength = 210 Mpa Wih Elongation % = 40 Min . Ink Mark Brand Printing On Hard Tubes Should Be Present. Material Test Certificate Required With Each Supplied Material. Piping Between Each Set Of Indoor & Outdoor Units Of Different Sizes As Per Oem Requirement & Specifications Including Chase Cutting, Supports, Making Good The Same With Sand Cement Plaster Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products / Work , Refer Annexure A Attached With This Bsr .

Key Value

Document Fees
INR 500 /-
EMD
INR 3000.0 /-
Tender Value
INR 1.50 Lakhs /-

BOQ Items

Name of Work: uxj fuxe chdkusj dk;kZy; ds fuekZ.k vuqHkkx] lkekU; "kk[kk ,oa dejk la[;k 11 esa ,;j d.Mh"kuj LFkkiu dk;ZA
Sl. No. Item Description
1Supply , Installation, Testing and Comissioning of ISO certified company made Air Cooled Hi Wall split type Air conditioners with latest star rating system as per BEE amended upto date complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU), R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. Min 5 year OEM warranty both compressor and PCB. NABL accredeated as per IS/ISO/IEC 17025 standards / CPRI/ ERDA lab testing reports as per IS 1391(Part-2) 2018 with OEM certificate must submitted to engineer in charge. All as per pre approved by Engineer in charge. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . Non Invertor Type 1.5 TR with 3 star rating of BEE (ISEER not less then 3.5) .
2Supply & fixing of external thermal closed cell elastomeric nitrile rubber Insulation material FM/UL approved with high water vapor diffusion resistance and low thermal conductivity should be certified "Class O" in Fire Propagation as per BS 476 Part 6 in form of tubular insulation between each set of indoor & outdoor units as per specificationsnitrile including cost of adhesive complete as per specification and as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . 6mm thick insulation and 16 mm internal Dia
3Supply & Fixing of FR PVC insulated & sheathed 3 core flexible copper conductor as per PWD specification for electrical Works confirming to IS:694 and as per IS 8130 : 2013 of 1.1 kV grade .Wire should be made from 99.99% purity copper, class 5 stranding in acc. to IEC 60228 for lower watt loss , oxygen free ( <10 ppm) for less chances of oxidization and higher silver content for gives better conductivity , insulation PVC type A ,flame retardant as per IS 10810-53, better amperage rating as per VDE 0298 part 4 including making connection etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. All as per pre approved by Engineer in charge, making connections. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .2.5 Sq.mm
4Supply, Fixing and testing of following capacity ISO certified company made wall mounted stabilizer having output voltage variation from 200 V to 250 V(+/-5%) with input voltage variation from 170 V to 260 V, time delay facility from 2 to 4 minute and high cutoff at 270 V with providing of 16 Amp plug top making connection etc complete in all respect. NABL accredeated / CPRI/ ERDA lab testing reports with OEM certificate must submitted to engineer incharge. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .3 kVA
5Dismentling of split air conditioner of any capacity/any type including existing indoor unit & outdoor unit , refrigerant piping , connecting cables , drain pipe etc. including shifting of dismentaled material to store complete as required
6Supply & fixing MS powder coated stand suitable for 1.0/1.5/ 2.0 Tr outdoor type of Split AC. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
7Providing & Fixing of recessed/surface mounting type sheet steel / Plastic enclosure as per PWD specification for electrical Works conforming to IEC 61439-3 of not less then 1.2 mm thick for housing MCB/Isolator with Din rail including , all as per pre approved by Engineer in charge,making connections, with lugs, repairs etc. as required.OEM shall have submit NABL / CPRI / ERDA accrediated lab test reports before execution & All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . With plastic enclosure Two way.
8Providing & Fixing of 240/415 V AC MCB with positive isolation of breaking capacity not less than 10 KA (B/ C tripping characteristic as per type of load and site requirement) 4KV impulse withstand voltage, as per PWD specification for electrical Works with ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. , conductor line load reversibility, label holding facility , IP 20 contact protection and fitted with existing distribution board/sheets, min. operation 20,000 upto 32 A rating and 10,000 upto 63 A, 5000 for 80 A rating including making connections, testing etc. as required. . OEM shall have submit NABL / CPRI / ERDA accrediated lab test reports before execution & All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . 6 A to 32 A rating
9Wiring of 3/5 pin 6 amp. Light plug point as per PWD specification for electrical Works with ISI marked 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade (IS:694) and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth Conductor 1.1 kV grade(IS:694) on surface ISI marked ( IS:14927 P - II ) UPVC casing capping & it"s accessories like coupler, inner, outer, elbow, square box, tee, end cap etc., recessed 18 SWG suitable G. I. box with earth terminal/ surface UPVC Box with earth terminal, 6 A switch, 3/5 pin 6 A socket, 3.0 mm thick ISI marked phenolic laminated sheet (IS : 2036 - 1995), Al. alloy/ cadmium plated iron screws 20 mm cup washers etc.all as per pre approved by Engineer in charge,making connections, testing etc. complete as required. For specification of copper Conductor, Phenolic Laminated sheet"s & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 . For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . Short point (up to 3 mtr.)
10S&F following sizes of ISI marked ( IS:14927 P - II ) UPVC casing capping as per PWD specification for electrical Works along with all accessories like coupler, inner, outer, elbow, square box, tee, end cap etc. on surface with screws, expansion fasteners , All as per pre approved by Engineer in charge, making connections, testing etc. complete as required. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . 25 mm x 12 mm
11Supply , Installation, Testing and Comissioning of Interconnecting refrigerant copper pipe for split of DHE Grade C12200- ASTM B68, B75, chemical composition of copper %- 99.0 Min and Phosphorus %- 0.015 to 0.040 . For Annealed copper tube :- Tensile strength = 210 Mpa wih elongation % = 40 Min . Ink Mark Brand Printing on Hard Tubes should be present. Material Test Certificate required with each supplied material. Piping between each set of indoor & outdoor units of different sizes as per OEM requirement & specifications including chase cutting, supports, making good the same with sand cement plaster etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .