Repairs To Floorings Certain Rcc Work Plastering Leakage Of Seepage Joinery Replacement Of Ac Sheet And False Ceiling Aluminum Work Plumbing Guniting And External Periodical Services And Internal Wiring To Certains Md Accn At Af Station Arjanagrh, gurgaon-Haryana

Military Engineer Services-MES has published Repairs To Floorings Certain Rcc Work Plastering Leakage Of Seepage Joinery Replacement Of Ac Sheet And False Ceiling Aluminum Work Plumbing Guniting And External Periodical Services And Internal Wiring To Certains Md Accn At Af Station Arjanagrh. Submission Date for this Tender is 21-07-2022. Electrification Work Tenders in gurgaon Haryana. Bidders can get complete Tender details and download the document.




Tender Notice

32604437
Corrigendum : Repairs To Floorings Certain Rcc Work Plastering Leakage Of Seepage Joinery Replacement Of Ac Sheet And False Ceiling Aluminum Work Plumbing Guniting And External Periodical Services And Internal Wiring To Certains Md Accn At Af Station Arjanagrh
Open Tender
Indian
Haryana
gurgaon
21-07-2022

Tender Details

Repairs To Floorings Certain Rcc Work Plastering Leakage Of Seepage Joinery Replacement Of Ac Sheet And False Ceiling Aluminum Work Plumbing Guniting And External Periodical Services And Internal Wiring To Certains Md Accn At Af Station Arjanagrh

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 30-Jun-2022 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 07-07-2022
2 06-Jul-2022 Pospondednit Date 21-07-2022

Key Value

Document Fees
INR 500 /-
EMD
INR 72000.0 /-
Tender Value
INR 36 Lakhs /-

BOQ Items

Name of Work : REPAIRS TO FLOORINGS, CERTAIN RCC WORK, PLASTERING, LEAKAGE OF SEEPAGE, JOINERY, REPLACEMENT OF AC SHEET AND FALSE CEILING,ALUMINUM WORK, PLUMBING, GUNITING AND EXTERNAL PERIODICAL SERVICES AND INTERNAL WIRINGTO CERTAINS MD ACCN ATAF STATIONARJANAGRH UNDER GE AF GURGAON
Sl. No. Item Description
1B/R WORKS Demolition of stone slabs andtiles of any description or thickness in floors/walls, aprons etc laid bedded and pointed in any mortar.
2Demolition of cement concrete (unreinforced) in ground floors and pavings n exc 15 cm thickness ( below or above ground level) complete all as specified and as directed.
3Taking down cement plaster on brick walls & concrete surfaces & the like including raking out joints, hacking for key, scrubbing down with water etc., any description, including removal of rubbish outside MoD land, complete all as specified.
4M&L for Rendering 15 mm thick on brick or concrete surfaces in cement mortar (1:4) finished even and fair complete all as specified.
5M&L for Rendering 15 mm thick on brick or concrete surfaces in cement mortar (1:6) finished even and smooth without using extra cement, complete all as specified.
6M&L for Rendering 10 mm thick in cement mortar (1:3), as on concrete surfaces (such as top & sides of chajjas, beams, balcony ceiling etc.) finished even and smooth without using extra cement, complete all as specified and directed.
7Dismantling floor,hearth or wall tiling including cement mortar bedding (but not backing)removing serviceable tiles to store and rubbish off the permises complete all as specified and as directed
8M&L for First quality, Non skid ceramic coloured tiles, 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 Sq.m but not exceeding 0.16 Sq.m, laid in floors with neat cement slurry @ 3.00 kg/Square Metre over and including 15 mm thick screed bed of cement mortar (1:4) including pointing in white cement with pigment to match the shade of tiles and levelingthe floor with PCC 1:2:4 type B0 of required thickness if required to maintain slope etc., complete all as specified.
9M&L for First quality, Non skid ceramic coloured joint free tiles, 10 to 12 mm thick (square or rectangular) area of each tile exe 0.18 Sqm but n.exe 0.38 Sqm, laid in floors set and jointed with neat cement slurry @ 3.00 kg/Square Metre over and including 15 mm thick screed bed of cement mortar (1:4) including pointing in white cement with pigment to match the shade of tiles, and levelingthe floor with PCC 1:2:4 type B0 of required thickness if required to maintain slope etc. complete all as specified.
10All as per item No 09above but on vertical surfaces such as skirting fixed on and including 10mm thick rendering in cement mortar 1:4 as backing coat complete all as directed by Engr-in-charge.
11M & L forfirst quality coloured glazed ceramic tiles, fixed in pattern of different colour including border of size 300x 450 x 7mm thick as in vertical surfaces such as dado/skirting, set and jointed in neat cement slurry and pointed in white or coloured cement to match with colour of tiles laid on and including 10 mm thick rendering in cement mortar (1:3), including pointing in white cement with pigment to match the shade of tiles, complete all as specified and directed. Note :- Pattern of the tiles will be decided by GE at the time of execution.
12Supply and fixing, drapery rod of mild steel 25mm dia, ribbed/fancy type, PVC powder coated, any shade, including set of fixing brackets, for span not exceeding 2m, fixed to wall in repairs, with PVC finols/finnels, connected accessaries, rubber packing, required screws andPVC rawal plugs as required complete all as specified and as directed.
13M&L for Preparation of newly plastered surfaces of wall and applying two coats of cement base paint complete all as specified and directed.
14M & L for preparation of newly plastered surface of ceiling and applying three coats of white wash up to 4 mtr height. complete all as specified and as directed.
15Material and labour for preparation of new plastered surfaces and apply two coat of oil bound distmperover a coat ofprimer, complete all as specified and directed.
16Supply and fixing in repairs, stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed to steel frames with tinned tacks, or galvanized wire staples, or fixed to wooden frames with first class hard wood bead,complete all as specified and directed.
17Supply and fixing, stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed to steel frames with tinned tacks, or galvanized wire staples, or fixed to wooden frames with first class hard wood bead,complete all as specified and directed.
18M&L for complete removal of existing treatment by scraping down completely on brick wall/concrete surfaces thoroughly, washing, rubbing down with water cleaning the surface upto the entire satisfaction of Engineer-in-Charge and includingopening ofexisting cracks , filling up of "V" cracks with epoxy expandable putty to required depth, making good weak plastereded/unplastered surfaces with cement plaster in CM 1:4 inclnecessary filling and applyingof Birla whiteputty on entire surfacesto obtain/achieve smooth even surfaces with using sand paper and applying two coat of exterior emulsion paint 100% acrylic of approved colour and shade by accepting officers over and including a coat of primer as per manufacturers instrctionscomplete all as specified and directed by Engineer-in-Charge. including necessary scafolding upto 4th floor.
19All as per srl item No 18above but without complete removal and applyingone coat of exterior emulsion paint 100% acrylic of make given in item No 18 above on old decorated surface includingopening ofexisting cracks , filling up of "V" cracks with epoxy expandable putty to required depth , making good weak plastereded/unplastered surfaces with cement plaster in CM 1:4, including necessary form work upto 4th floor. complete all as pecified and as directed.
20M&L for complete removal of existing treatment by scraping down completely on brick wall/concrete/plasteredsurfaces thoroughly, washing, rubbing down with water cleaning the surface upto the entire satisfaction of Engineer-in-Chargeand a primer coat of " cemprover of M/S Snocem on entire surfaces and filling the craks/depression/holes etc by putty as directed and making good weak plastereded/unplastered surfaces with cement plaster in CM 1:4 thanapplying two coat of cement base paint coating of approved colour and shade by accepting officers on walls upto 4th floor complete complete all as specified and directed by Engineer-in-Charge.including necessary form work upto 4th floor.
21M&L for complete removal of existing treatment by scraping down washing rubbing down with water and cleaning the surface up to the entire satisfaction of Engineer-in-Charge and includingopening ofexisting cracks , filling up of "V" cracks with epoxy expandable putty to required depth, making good weak plastereded/unplastered surfaces with cement plaster in CM 1:4 applying two coat of oil emulsion over 2 to 3 mm thick birla putty punningcomplete all as specified or as directed by Engineer-in -Charge.
22M&L for Preparation of old surfaces of ceiling including brooming down or steel wire brushing; scrapping downsmoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots etc. and applyingone coat of white wash up to 4 mtr height , complete all as specified and directed.
23M&L for Preparation of old painted surfaces of wood based surfaces of any description over 10 cms width or girth by applying sand paper etc.for proper preparation and applying onecoat of synthetic enamel paint to give an even and smooth surface having no sign of brush marks all as specified and directed.(Note-Payment shall be made for one coat only ) complete all as specified and directed.
24M&L for Preparing old painted surfaces of steel and iron surfaces over 10 cm width or girthby cleaning, sand papering, brushing with wire brushes, scrapping by steel scrappers etc , filling in crevices and cracks etc with approved fillerand applying One coats of synthetic enamel paint complete all as specified and directed by Engineer-in-Charge.
25Taking down steel tubing 15mm bore and connections including cleaning for refixing or removing to stores completeall as specified and directed by Engineer - in – Charge.
26All as per Srl Item No 25 here in before but 20mm bore all as specified and directed by Engineer - in - Charge.
27S & F 15mm dia tubes medium grade, galvanized, with all fittings such as sockets, bends, elbows, tees etc, concealed/surface fixed to walls and ceiling or laid in floors complete all as specified and directed. Note : Cutting chases as required shall be measured and paid seperately.
28S & F 20 mm dia tubes medium grade, galvanized, with all fittings such as sockets, bends, elbows, tees etc, concealed/surface fixed to walls and ceiling or laid in floors complete all as specified and directed. Note : Cutting chases as required shall be measured and paid seperately.
29M&L for Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exceeding 10 cm girth, including removal of rubbish outside MoD land complete all as specified.
30S & F in repairs Ist quality vitreous china wash basin, white, flat back, size 550x400mm, PVC connections suitable for hot and cold water,bottle trap (with internal partition) 32 mm size with 300mm &190mm long wall connection pipes & wall flange,and fixing withbrackets/bolts including cutting and pinning in etc complete all as specified and directed by Engineer - in – Charge .
31All as above in item No 30but fixing only.
32Supply and fix in repairs Cast ironfloor trap with dia of outlet 100 mm, with CP gratinghinge type in kitchen and other situation including PCC 1:2:4 type B1 for setting the trap and jointing to waste pipe including taking out old floor trap , complete all as specified and directed.
33Supply and fix in repairs Cast ironfloor trap with dia of outlet75mm, with CP gratingwith hinge in kitchen and bath etcsituation including PCC 1:2:4 type B1 for setting the trap and jointing to waste pipe including taking out old floor trap , complete all as specified and directed.
34Dismantling of cast iron or reiforced concrete drain pipes jointed in cement mortar and taking out from trenches 100 / 75 mm bore (sand cast) all as specified and directed
35Material and labour for, 100mm dia cast iron soil, waste and vent pipes (sand cast) in any length with or without ears, including cement jointing, laid in trenches or in floors including necessary excavation and earth work, complete all as specified and directed.
36Material and labour for, 100mm dia cast iron soil, waste and vent pipes (sand cast) in any length with or without ears, including cement jointing, fixed to wall with and including mild steel clamps and bolts with washers, complete all as specified and directed.
37Material and labour for, 75mm dia cast iron soil, waste and vent pipes (sand cast) in any length with or without ears, including cement jointing, laid in trenches or in floors including necessary excavation and earth work, complete all as specified and directed.
38Material and labour for, 75mm dia cast iron soil, waste and vent pipes (sand cast) in any length with or without ears, including cement jointing, fixed to wall with and including mild steel clamps and bolts with washers, complete all as specified and directed.
39S & F 100mm bore bends, diminishing pieces or tapers all as specified and directed
40S & F 75mm bore bends, diminishing pieces or tapers all as specified and directed
41Supply and fix VitreousChina wash down water closet"constellation premiumwhitecolourcomplete set incl cistern with lid cover fixed in repairs, including connection to wate pipe, flushing pipe, anti-syphonage pipe etc. and making good to floor complete all as specified and directed
42Dismantling Asbestos cement sheets (corrugated ,semi corrugated etc) in roof coverings incl rigdes etc complete.
43M&L for Pre-painted galvalume aluminum zinc coating GI based corrugatedsteel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screwsallas specified and as directed.
44M&L for Cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate as in foundation, filling and mass concrete , sub base all as specified and directed
45M & L for 40 mm thick Cement Conrete1:2:4 type B–1 using 20mm graded stone aggregates inflooring laid in alternate panel of sizes as directed andfinished even and smoothusing extra cement all as specified and directed
46Supply only liquid waterproofing compound
47Dismantling/removingold damaged worn out APP of any thicknessincl screed bed or plastering of anythickness and removing the rubish materials outside MOD land at a dumping place earmarked marked by any state govt/municipalities etc any distance complete.
48Material and labour for, 15 mm thickcement plaster in CM (1:4) mixed with WPC as per manufacturer’s instructions @ 3% by weight of cement on concrete surfaces, finished even and smooth without using extra cement complete all as specified and directed. Note : WPC shall be measured and paid separately.
49M&L for Cutting groove in brick wall 75 mm wide and 65 mm deep for inserting APP polymer membrane and shaping horizontal face of groove with cement mortar 1:3, including removal of rubbish outside MoD land, complete all as specified.
50Material and labour for , water proofing treatment of roof consisting as under:- (a) Applyinga tack coat of industrial bitumen 85/25 at the rate of 1.20 kg per sqm over a coat of primer @ 0.30 litre/ sq.m including preparation of roof surfaces (b) A layer of 3mm thick APP polymeric membrane of weight not less than 3.60 kg/sqm, reinforced with polyester non-woven fabric (weight not less than 160gm/sqm), duly sealed at over laps & joints with flame (by torch application) all as per manufacturer’s instructions complete all as specified and directed.
51All as per Srl item No. 50here-in-before but on vertical surfaces, using hot blown bitumen having penetration value 30/40 applied1.20 Kg/ Sq.m over primer @ 0.30 litre/ Sq.m, complete all as specified and directed
52S&F in repairs vitreous china squating pan, "Orissa"pattern, size 580x440mm white, with integral foot rests, including 100mm cast iron "P" or "S" trap and 100mm cast iron sanitary connection socket to fit WC outlet including connection to trap, to flushing pipe, anti-syphonage pipe etc. complete including making good to floor complete all as specified and directed.
53Supply and fix VitreousChina wash down water closet (pedestal pattern), white (excluding fixing bolts flushing cistern and flush pipe), fixed in repairs, including connection to wate pipe, flushing pipe, anti-syphonage pipe etc. and making good to floor complete all as specified and directed.
54S&F Rotational moulded polyethylene water storage tank 500 litres capacity, ISI markedtriple layer construction (cylindrical vertical closed top), hoisted & fixed in position including S&F Ball valves, high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball, screwed for 20mm bore GI pipe of having weight not less than 210gms including all fittings and gate valves with iron wheel head 20mm size, including taking down existing tank complete all as specified and as directed.
55S&F Rotational moulded polyethylene water storage tank 1000 litres capacity, ISI markedtriple layer construction (cylindrical vertical closed top), hoisted & fixed in position including S&F Ball valves, high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball, screwed for 20mm bore GI pipe of having weight not less than 210gms, including all fittings and 20mm size gate valves with iron wheel head including taking down existing tank complete all as specified and as directed.
56S & F in repairs 10 litres capacity, PVC valve less, syphonic action type,flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets and suitable flush pipe PVC 32mm dia complete all as specified and directed.
57S & F in repairs 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall complete all as specified.
58S & F in repairs 75 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall complete all as specified.
59S & F in repairs 110mm bore PVC (SWR) bends any radius complete all as specified.
60S & F in repairs 75 mm bore PVC (SWR) bends any radius complete all as specified.
61S&F in repairs 15mm dia gun metal gate valve, with iron wheel head, screwed both ends for iron pipes complete all as directed
62S&F in repairs 20mm dia gun metal gate valve, with iron wheel head, screwed both ends for iron pipes complete all as directed by Engr in Charge.
63S&F PVC connection 15mm size with PTMT nuts of length 450mm complete all as specified and directed.
64S&F in repairs PVC Grating 100 mm dia with or without waste hole of brass chromium plated fixed on floor/ nahani trap with cement mortar, fixed in repairs, complete all as specified and directed.
65S & f in repairs bib taps, cast copper alloy, chromium plated, with crutch or butterfly handle, screwed down, screwed for 15 mm bore iron pipe or for brass ferrule complete all as specified.
66S & F in repairs Pillar taps (Single Touch type), cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered "Hot" or "Cold" with long screwed shanks and fly nuts, screwed for 15mm bore iron pipe and pillar tab to be prior approval from Engr in Charge complete all as specified.
67S & F in repairs angle cock/stop valves, cast copper alloy, chromium plated, fancy type, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for 15 mm bore iron pipe or for brass ferrule complete all as specified.
68S & F in repairs stop valves, cast copper alloy, chromium plated, fancy type, with long shank and cup (concealed type),screwed down, high pressure, with crutch or butter fly handle, screwed both ends for 15mm bore iron pipe or for unions complete all as specified.
69Demolition of brick masonry built in cement mortar as in drain etc., complete all as specified.
70M&L Brick masonry with sub class B bricks straight or curved on plan exceeding 6m mean radius, built in Cement Mortar (1:4)all as specified and directed.
71S&F false ceiling with exposed GI system using “SILHOUETTE XL 15 mm (Nominal) designer Grid "Armstrong"white or Global white with black reveal and 600 x 600 x 15 mm thick prime fine fissured micro look white/coloured tiles (superfine 15mm/silhouette). Making necessary framework for AC ducting, if any and necessary cutouts for diffusers and light fittings, taping and finishing to proper line & level and incl dismantling old undervicable false ceillingcomplete all as per manufacturer’s instructions and as directed.
72M&L for averaging 1 to 2 mm thick putty and applying one coat of primer complete all as specified and directed
73Taking down chowkats or frames with shutters (with out taking off shutters from the frame) not exceeding 1.50 Sqm each all as specified and directed
74Taking down chowkhats or frames with shutters without taking off shutters from the frame exceeding 1.5 Sqm but not exceeding 4 Sqm each andall as specified and directed
75Taking down shutters of any description not exceeding 1.00 Sqm each all as specified and directed
76Taking down shutters of any description exceeding 1.00 Sqm and not exceeding 2.0 Sqm all as specified and directed
77S & F 35mm thick 2nd class hard wood glazed and skeleton shutters, open rebated and prepared to receive glass, gauze etc. (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc.; size of members of shutters as specified in SSR Part –I, Section 8, clause 8.20 (a) ; supplied and fitted to chowkats all as specified and directed
78S & F flush shutter 35mm thick solid core construction with block board core and plywood face panels commercial type on both sides with lipping / frame to match all as specified and directed
79M&L for Factory made solid panel PVC door shutter 30mm thick (Style) consisting of frame made out of MS tubes for top and bottom rails. MS frame shall be covered with heat moulded coloured PVC ’C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and single sideprelaminated PVC sheets for top rail, lock rail and bottom rail on either side and as gap insert for top rail and bottom rail; Panelling of single sideprelaminated PVC sheet to be fitted in the MS frame welded/ sealed into the stiles and rails with suitable PVC sheet beading, and jointed together with solvent cement, supplying andfixing in the frame at site as per specification complete all as specified and as directed
80S&F Factory made PVC solid door frame of size 50 mm x 47 mm with wall thickness of 5 mm made out of5 mm thick plain colour PVC sheet cut at corner and jointed with 02 Nos., 150 mm long brackets of size 15 mm x 15 mm mild steel square tubes 19 gauge including vertical door profiles reinforced with 19 mm x 19 mm steel square tube of 19 gauge (EPDM) rubber gasket weather seal provided throughout the frame and fixed to wall with 65/100 mm long mild steel screws through the frame by using PVC fasteners (minimum of 04 Nos. of screws to be provided for each vertical member & minimum 02 Nos. for horizontal member), complete all as specified.
81S & F mild steel tower bolts, stove enamelled black, with bright bolt and fixed, length of bolt 200mm long all as specified and directed
82S & F mild steel sliding door, bolts, plate type, stove enamelled black with bright bolt not less than 12mm bore, length of bolt 250mm all as specified and directed
83S & F mild steel, 300mm, ordinary rat rail rod pattern spring including roller and roller plate complete all as specified and directed
84S & F mild steel pressed handles oval type, stove enamelled black 125mm size all as specified and directed
85S & F SS butt hinges, medium weight100mm size all as specified and directed
86S & F pressed steel door frames with one or more rebates including necessary fixing lugs hinges lock strike plate etc complete all as specified size of frame 125 x 60mm all as specified and directed
87M&L Cement concrete 1:3:6 type C–1 filling of pressed steel frame and hold fast blocks etc all as specified and directed
88M&L for Cutting hole in brick wall built in cement mortar exceeding half brick but not exceeding one brick and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4, type B – 1 all as specified and directed
89S & F mild steel work for hold fasts,wall ties, ,bands, strapsclamps, handles for manhole coversetc confirming to Fe- Fe 290grade- E165 all as specified and directed
90Taking down old steel /wooden windows & M&L for factory made box type steel window with pintol hinges & 2 Nos 150mm mild steel tower bolts to each shutter, steel handle and with glazing bars dovetailed or welded and with one shop coat of zinc chromate primer complete all as specified.
91Taking down old steel /wooden windows & M&L for factory made box type steel window with pintol hinges & 2 Nos 150mm mild steel tower bolts to each shutter, steel handle and without glazing bars dovetailed or welded and with one shop coat of zinc chromate primer complete all as specified.
92S & F mild steel as in framed work as in doors or gates of angles or other sectionetc. complete, drilled for fixing of steel sheeting or other covering.Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive for steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing incl MS hinges ,handles ms sheets 0.63 mm thick complete Fe 410-0 all as specified and directed
93S&F powder coated aluminium frame work fordoors, windows,partition s etc incl grill for windows for windows etc with one or more rebated section incl jointing cleats for fixingetc complete complete.
94S&F powder coated anodised aluminium door shutters, partition wall, aluminium section weighting 0.55 Kg/Rm incl necessary joining cleats glazing clips rubber neoprene packing, handles two Nos in each door, hinges anodised aluminium snap beading screws etc complete all as specified and as directed.
95S&F powder coated anodised aluminium window and ventilator shutters , side hung type without sash bars aluminium section weighting 0.55 Kg/Rm incl necessary joining cleats glazing clips rubberpacking, aluminium anodised snap beading, screws, anodised aluminium fittings such as peg stays 150 mm long (1Nos0, hinges type B-21 100 mm long(2Nos) suitable handles (1Nos)complete all as specified and as directed.
96S&F 12mm thick prelaminated board, exterior grade, prelaminated one side with decorative choice lamination and other side balancing white lamination fixed with screws to aluminium frame work complete.all as specified and directed
97S&F 5.5 mm thick selected quality tinted sheet glass and glazing clip in square fixed with PVC/neoprene gasket in aluminium frame work compelte. all as specified and directed
98S&F double action floor spring hydraulic regulated made up of min 1.25 mm thick aluminium sheet foundation box, main body with stainless steel cover, govering pivets made of brass, other part made up of mild steel heavy duty complete. all as specified and directed
99S&Fbrass six lever dead lock suitable for aluminium doors manufactured by Harrison Locks or Godrej as approved
100Taking down aluminium door shutter of any size upto 4 Sqm each and replacement of defecting pivot with new pivot & refixing in position complete all as specified and directed
101Taking down aluminium door shutters of any size upto 4 Sqm each replacement of defecting floor spring with new floor spring make : Amar/Sandhu.
102S&F in repair dead lock6 lever brass for aluminium door shuttercomplete all as specified and directed
103Taking down old broken glass from aluminium door, window or partition panel by removing glass clips and S&F glass ordinary 5.0mm thick in any size and refixing the glass clips in position after replacing rubber gasketcomplete all as specified and directed
104S&F in repair Hydraulic door closer for aluminium door shutter complete all as specified and directed
105Material and labour, 18-20 mm thick machine cut kota stone slab as in flooring, steps of stair(treads), set with neat grey cement slurry @ 3Kg/Sqm, laid over and including 20mm thick cement and sand mortar (1:6) screed bed/bedding layer, jointed with grey cement slurry mixed with pigment to match the sahde of the slab including rubbing and polishingincl dismantl ing damaged stone slab of any description complete all as specified
106Material and labour, machine cut kota stone slab 18-20mm thick as in skirting/dado, riser of steps, laid over and including 10mm thick backing coat in CM (1:4), set in neat grey cement slurry @ 3Kg/Sqm, and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing, complete all as specified and directed.
107Hacking out old broken glass (any thickness size, quality or description) from wooden/ steel frames, glazed with putty or fixed with wooden beads/ metal pins complete all as specified and as directed.
108S & F 3mm thick Sheet glass ordinary quality and glazing with oil putty or wooden bead in squares not exceeding 0.5 Sq. m in each pane, complete all as specified.
109S & F 3mm thick figured glass, pin headed type and glazing with oil putty or wooden bead in squares not exceeding 0.5 Sq. m in each pane, complete all as specified.
110Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for (reinforcement cut as required to facilitate demolition), complete all as specified.
111M&L for providing precast reinforcement cement concrete (1:2:4) type B-1 using 20mm graded aggregate in man holes covers slabs/ Shelves as in slabs supported on walls, beams and columns, in floors, roofs, landings, deck slabs and in shelves and like including necessary form work, complete all as specified and directed
112M&L for Preparation of new wooden surfaces & applying two coats of synthetic enamel paint over a coat of pink primer to wood surfaces over 10 cm in width or girth not otherwise described, complete all as specified.
113M&L for Preparation of new steelsurfaces & apply 2 coat of synthetic enamel paint over a coat of red oxideover 10cm in width or girth not otherwise described, complete all as specified.
114M&L for Applying two coats of exterior acrylic emulsion (weather proof treatment ), over a coat of primer in , over new plastered surfaces , including preparation new surfaces , complete all as specified and directed
115S&F in repairs mild steel framed work such as grills, gratings, cooler stand, brackets for sunshed etc with end bars of shouldered and or riveted or gorged into spikes, framed guard bars, barred iron doors, ladders frmamed balusters, walkways, rialings and similar work confirming to Fe-290 Gde E-165 complete.
116E/M WORKS Taking down carefully copper/aluminium point wiring (light, fan, socket, bell or power) completeincluding all electrical fittings & fixtures(DBs, submain,cables etc) and making good disturbed surfaces of wall , floor etc and matching wth original colour of wall, complete, all as specified & directed.
117M & L for replacement of concealed point wiring complete with PVC insulated and unsheathedFRLS cable of 1.5 sqmm (nominal area) with multistranded copper conductor single core 1100 volts grade in and including rigid PVC conduit ISI marked medium grade not less than 20 mm dia,with MS terminal boxes (not less than 1.6mm thick) and painted with one coat of red oxide primer all around and two coats of black bituminous paint from out side and two coat of aluminum paint from in side including earth dollywith3 mm thick plastic laminated sheet top cover of approved make and colour including 1.5 sqmm multistranded copper conductor cable of green colour as continuous earth wire with lugs and accesseries and making good disturbed surfaces of walls/floor etc complete all as specified anddirected for the followings :-
118One light / fan point controlled by one way switch
119One 5 Amp socket outleton independent board.
120One5 Amp socket outlet on same board.
121One bell/buzzer point controlled by one bell push
122One light point controlled by two 2-way switch
123All as per above item No 117 here in before but using 2.5 sqmm single core multi stranded copper conductor PVC insulated and unsheathed,FRLS cable for 15 Amp socket outleton independent board including 2.5 sqmm multi stranded copper conductor cable of green colour as continuous earth wire with lugs etc as required complete all as specified andas directed.
124M&L for replacement of point wiring in casing caping on sufraces of wall/ceiling floor etc complete with PVC insulated and unsheathedFRLS cable of 1.5 sqmm (nominal area) with multistranded copper conductor single core 1100 volts grade in and includingPVC conduit , with mild steel terminal boxes (not less than 1.6 mm thick ) and painted with one coat of red oxide primer all around and two coats of black bituminous paint from out side and two coat of aluminum paint from in side including earth dollywith3mm thick plastic laminated sheet top cover of approved make and colour including 1.5 sqmm multistranded copper conductor cable of green colour as continuous earth wire with lugs and accesseries and making good disturbed surfaces of walls/floor etccomplete all as specified and as directed for the followings :-
125One light / fan point controlled by one way switch
126One 5 Amp socket outleton independent board.
127One5 Amp socket outlet on same board.
128One bell/buzzer point controlled by one bell push
129One light point controlled by two 2-way switch
130All as per above Item No 119 here in befor but using 2.5sqmm single core multi stranded copper conductor PVC insulated and unsheathed, FRLS cable for15 Amp socket outleton independent board including 2.5 sqmm multi stranded copper conductor cable of green colour as continuous earth wire with lugs etc as required complete all as specified andas directed.
131M & L for replacement ofpoint wiring in existing conduit (PVC/Steel) surface / concealed includingexisting MS Terminal boxeswith1.5 sqmm FRLS PVC insulatedmulti stranded copper conductor cablesingle core 1100 volts gradeand one run of 1.5 sqmm multistranded copper conductor cable of green colouras continuous earth wireand laminated sheet cover 3 mm thick on terminal box duly fixed including taking out old u/s wire of any type and size complete all as specified and as directed for the followings :-
132One light / fan point controlled by one way switch
133One 5 Amp socket outleton independent board.
134One5 Amp socket outlet on same board.
135One bell/buzzer point controlled by one bell push
136Ditto all as per above item no 121 but using 2.5 sqmm single core multi stranded copper conductor PVC insulated and unsheathed, flame retardant ( FRLS ) cable for15 Amp socket outleton independent board including 2.5 sqmm multi stranded copper conductor cable of green colour as continuous earth wire with lugs etc as required complete all as specified and as directed.
137S&F in replacement switch piano type 5 amp one way ISI Marked complete all as specified and directed
138S&Fin replacement switch piano type15 Amps one way ISI Marked complete all as specified and directed
139S&F in replacement socket outlet 3 pin 5 Amps flush type complete all as specified and directed
140S&F in replacement socket outlet 2-in-1, 3 pin 5 amp and 15 amps all as specified and directed.
141S&F in replacement socket outlet 6A-2/3 Pin combined 2 module modular type complete all as specified and directed. Make : 1.Carb tree,2. Roma, 3.Havells
142S&F in replacement socket outlet 6A/16A-2/3 pin combined 2 module modular type complete all as specified and directed.Make : Make : 1.Carb tree,2. Roma, 3.Havells
143S&F in replacement switch 6 amps modular type one one way complete all as directed.Make :Make : 1.Carb tree,2. Roma, 3.Havells
144S&F in replacement switch 16 amps modular type one one way complete all as directed.Make :Make : 1.Carb tree,2. Roma, 3.Havells
145S&F in replacement electronic fan regulator Step type complete all as specified and directed.Make-1.Carb tree,2. Hager, 3.Havells
146S&F in replacement bell push flush type 5 amp one way ISI Marked complete all as specified and directed.
147S&F in replacement modular type bell push 6 amp one module ISI Marked complete all as specified and directed.
148S&F in replacementBell, DING DONG AC 230 Volts single pole type complete all as specified and asdirected.
149S & F in replacement ofLamp holder bakalite type with back plate suitable for batten fittingscomplete all as specified as directed
150S&F in replacement of ceiling rose surface bakelite 63 x50mm three terminals completeall as specified and asdirected.
151S & FWall fan ofsingle phase 230/240V of size 400 mm sweep and grouting withnut , bolts & Fastenaron the wall and make good the disturbed surface and electric connection with 1.5 Sqmmthree core PVC insulated round flexible copper conductor and sheathed cable complete all as specified and directed by Engr-In - Charge. Make:Havells or equivalent Make of CG / Bajaj.
152Supply & fixfans ceiling complete with electronic type regulator and accessories 230 V,1200 mm sweep. BEE 5 star rated complete all as specified and directed. Make- Havells/halonix/usha/Orient
153Supply & fix exhaust fans heavy duty 300 mm dia 1400 RPM, 50 Hz 230 volt for domestic use,dynamically balance blade , epoxy powder coated confirm to IS 2312-1967 with ISI marking IP-55 with class B insulation motor including suitable size louver and all fixing accessories such as fastners nut bolts and electric connection with 3 core cablecomplete all as specified and directed. Make -Havells/crompton/ bajaj.
154Supply and fix in replacement Exhaust fan 380 mm sweep complete with brackets frame and blades, metalic body heavy duty with louvers suitable for 240V 50 Hz supply , make Havells. / crompton /Bajaj ( Old fans will be deposited to factory authorities)
155Supply and fix in replacement Exhaust fan 450 mm sweep complete with brackets frame and blades, metalic body heavy duty with louvers suitable for 240V 50 Hz supply , make Havells. / crompton /Bajaj ( Old fans will be deposited to factory authorities)
156S&F in replacement of sheet metal enclosure double door concealed suitable for SPN distribution boards when MCB to be used having 200 Amp rated bus bar 12 ways 240 V complete all as specified and as directed .
157S&F in replacement of sheet metal enclosure double door suitable for SPN distribution boards when MCBs to be used having 200Amp rated bus bar 8 ways 240 V complete all as specified and as directed.
158S&F in replacement of sheet metal enclosure double door concealed suitable for SPN distribution boards when MCB to be used having 200 Amp rated bus bar 4 ways 240 V complete all as specified and as directed .
159S&F in replacement of single pole and neutral enclosure with 2 pin and earth plug and socket complete with one single pole MCB 10-32 complete all as specified and as directed.
160S&F in replacement MCB SP 5 to 32 Amps,240 volts curve "C",breaking capacity 10KA,all as specified.
161S&F in replacement MCB SPN5 to 40 Amps,240 volts,curve "C", breaking capacity 10 KA, all as specified.
162S&F in replacement MCB SPN50 to 63 Amps,240 volts,curve "C", breaking capacity 10 KA, all as specified.
163S&Fin replacement of1100 Volts grade heavy duty cable PVC insulated stranded aluminium conductor served with inner sheathing of PVC tape & overall PVC sheathed in service connection suspended by insulating hanger not more than 1 meter apart including 4 mm GI suspension wire one twin core cable flat or circular of size 10 Sq mm to be connected to existingMCB box / Main switches complete all as specified as dircted.
164S & F In replacement ofmodular switch 2 way, 6 Amp,1 module ISI Marked complete all as specified and asdirected.
165S & F in replacement ofmodular Fan Regulator fan step regulator,120W-2 module ISI Marked complete all as specified as as directed.Make : Havells Fabio 2.Carb tree, or its equivalent
166S & F In replacement ofPiano type switch 2 way, 5 Amp,1 module ISI Marked complete all as specified and asdirected.
167S&F in replacement ofmodular blanking plate, 1 module ISI Marked complete all as specified and as directed.
168S&F in replacement metal flush box 1/2 module all as specified and directed.
169S&F in replacement metal flush box 3 module all as specified and directed.
170S&F in replacement metal flush box 6 module all as specified and directed.
171S&F in replacement metal flush box 8 module all as specified and directed.
172S&F in replacement metal flush box 12 module all as specified and directed.
173S&F in replacement for white cover plate with frame, 1/2 module all as specified and directed.
174S&F in replacement for white cover plate with frame, 3 module all as specified and directed.
175S&F in replacement for white cover plate with frame, 6 module all as specified and directed.
176S&F in replacement for white cover plate with frame, 8 module all as specified and directed.
177S&F in replacement for white cover plate with frame, 12 module all as specified and directed.
178S&F in replacement ofHylem sheet 12"x15" complete all as specified and as directed.
179S&F in replacement of Hylem sheet 8"x5" complete all as specified and as directed.
180S&F in replacement ofHylem sheet 5"x5" complete all as specified and as directed.
181Supply and fixing in repair ofEarthing to panel with galvanised steel earth plate electrode60cm x 60cm x 6mm thick, buried directly in ground (earth pit not less than 2.25m below normal ground level) with top edge of earth plate not less than 1.5m below normal ground level connected to main earth lead 32 x 6 mm galvanised iron strip by means of bolts, nut, check nuts and washers of galvanized iron or steel all as shown in electrical plate No.3 of MES Schedule pt-I 2009, GI earth lead strip protected by GI pipe 40 mm dia light grade and connected to earth test point includingexcavation in any type of soil,returning filling, disposal of soil, providing charcoal dust and common salt upto top edge of earth plate, construction of PCC pit with RCC cover, funnel, watering pipe of 20mm dia GI light grade and provision of earth test point including testing on completion complete all as specified and as directed.
182M&L for earthing complete withGI plate electrodes 600x600x6.3mm thick buried directly in ground earth pit not less than 2.25m deep below normal ground level with top edge of earth plate not less than 1.5m below ground level connected to G Istrip 25x 4 mm as earthing lead fixed by means of nut bolt washer of brass as shown in electrical plate No.3 of SSR Pt-I 2009 including necessary excavation and earth work in any strata, GI pipe 20mm dia light grade for watering , and 40 mm light grade as protrection to earth wire upto 7.5 mtr ,charcoal & salt etc and PCC chamber in PCC 1:3:6 type C1 covered with 40mm thick RCC 1:2:4 type B1 using 20mm graded stone aggregate reinforced with 8mm dia MS bar @ 75mm C/C both ways cover, funnel & wire mesh including making of test point all as specified testing on complete.
183M&L for earthing complete withGI plate electrodes 600x600x6.3mm thick buried directly in ground earth pit not less than 2.25m deep below normal ground level with top edge of earth plate not less than 1.5m below ground level connected to G Iwire 4 mm as earthing lead fixed by means of nut bolt washer of brass as shown in electrical plate No.3 of SSR Pt-I 2009 including necessary excavation and earth work in any strata, GI pipe 20mm dia light grade for watering , and 15 mm light grade as protrection to earth wire upto 7.5 mtr ,charcoal & salt etc and PCC chamber in PCC 1:3:6 type C1 covered with 40mm thick RCC 1:2:4 type B1 using 20mm graded stone aggregate reinforced with 8mm dia MS bar @ 75mm C/C both ways cover, funnel & wire mesh including making of test point all as specified testing on complete.
184Supply and fixing in repair TPN DB"s 8 way vertical type 415 V, double door suitable for housing of 125 Amps MCCB as main incoming. Make : ABB/Legrand/Siemens/L&T/Indo Asian/C&S
185All as per item No. 170 above but of 4 way and suitable for housing of 100 A/63 A MCCB as main incomingMake : ABB/Legrand/Siemens/L&T/Indo Asian/C&S
186S & F MCCB 125 Amps capacity, 4 pole, 25 KA, fixed thermal and magnetic release complete with extended terminals to be fixed in 8 way TPN DB complete all as specified and directed.Make : ABB/Legrand/Siemens/L&T/Indo Asian/C&S
187All as per item No. 172 above but capacity 100 Amps, fixed thermal and magnetic release, 4 Pole, 25 KA suitable to be fixed in 4 way TPN DB complete all as specified and directed. Make : ABB/Legrand/Siemens/L&T
188Supply and fix in replacement double door TPN DBs 4 wayof powder coated DB"s suitable for MCB"s fitted with bus bar,Neutral link,Earth bar and Din ral & DB"s will be fitted concealed in wall / surface as per site required complete all as specified and directed .
189S & F in replacement with MCB TPN 32amps 10 KA ,c-series including connection with suitable size aluminium / copper lugs complete all as specified and directed .
190S & F in replacement with MCB TPN 50 to 63 amps 10 KA ,c-series including connection with suitable size aluminium / copper lugs complete all as specified and directed .
191S & Fin replacement with MCB TPN 100amps 10 KA ,c-series including connection with suitable size aluminium / copper lugs complete all as specified and directed.
192S & F in replacement enviroment friendly recess/pendent mounting LED flat panel 36/40 Watts 2"x2" fabricated CRCA sheet steel housing cool white with high efficient LEDs & glare free opal diffuser PF>0.95 driver life >25000 Hours, operating range 140v to 280 V includingall accessaries all as specified and directed. Wipro/Crompton/Bajaj
193Taking down electric energy meter of any size and type and deposite to MES store yard complete all as specified and directed.
194Supply and fixing in replacement microprocessor based three phase electronic tamper proof energy meter of rating 10 to 40 Amps,AC 415 Volts, 50 Hz covered with toughened glass coverwith optical comunication port confirming to IS 13779 complete all as specified and directed
195Supply and fixing in replacement microprocessor based single phase electronic tamper proof energy meter of rating 10 to 60 Amps,AC 240 Volts, 50 Hz covered with toughened glass coverwith optical comunication port confirming to IS 13779 complete all as specified and directed
196Supply and fixing in replacement microprocessor based single phase electronic tamper proof energy meter of rating 10 to 40 Amps,AC 240 Volts, 50 Hz covered with toughened glass coverwith optical comunication port confirming to IS 13779 complete all as specified and directed
197Taking down old metallic energy meter box of any size and type complete all as specified and directed.
198S&F in replacement of Energy meter Box Flame retardent polycarbonate body including all fixing arrangement like DIN rails mounting plate connection boxes fastning screw protection plate extra suitable to accomodate 3 Phase energy meter. the meter box shall be of SIze 450x300x214mmwith locking arragement complete all as specified and directed.
199All as per Item No 184 Above But to accomodate single phase energy meter of Size 300x300x170mm complete all as specified and directed.
200S&F in replacementenviroment friendly,ultra modern,energy saving surface mounted decorative 10 Watt LED bulkhead fitting with pressure die cast aluminium housing ,high efficient LEDs with opal diffuser and IP65 protection all as specified and directed. Make-: Havells/Bajaj/Halonix
201S&F in replacement of enviroment friendly indoor decorative 20 Watt LED polycarbonate Batten with opal diffuser including all accessaries all as specified and directed. Make:- Crompton/Bajaj/Wipro
202S&F in replacement of enviroment friendly indoor decorative 10 Watt LED mirror light polycarbonate Battenwith opal diffuser including all accessaries all as specified and directed. Make : Crompton/Bajaj/Wipro
203S & F in replacement of sub main wiring with PVC insulated, fire retardant (FRLS), unsheathed two single core cable 1100 volts grade with stranded copper conductor of size 4.0 sqmm (Nominal area) drawn into existing / newconduit of any size and type/ casing-caping with and including one run of2.5 sqmm multistranded copper conductorsingle core PVC insulated, unsheathed cable of green colouras continuous earth wire including lugs etcconnected and tested complete all as specified and as directed. Note: (i) New conduit/ casing- caping andaccessories shall be measured separately. (ii) Two runs of 4.0 sqmm cable and one run of 2.5 sqmm cable of earth continuity conductorshall be a unit length.
204S & F in replacement ofsub main wiring with PVC insulated, fire retardant (FRLS), unsheathed two single core cable 1100 volts grade with stranded copper conductor of size 6.0 sqmm (Nominal area) drawn into existing / newconduit of any size and type/ casing-caping with and including one run of4.0 sqmm multistranded copper conductorsingle core PVC insulated, unsheathed cable of green colouras continuous earth wire including lugs etcconnected and tested complete all as specified and as directed. Note: (i) New conduit/ casing- caping andaccessories shall be measured separately. (ii) Two runs of 6.0 sqmm cable and one run of 4.0sqmm cable of earth continuity conductorshall be a unit length.
205S & F in replacement ofRegid non-metallicPVCconduit25 mm(external dia) ISI marked (on surface) incl of all accessories and all fittings such as Tees bends, elbows, reducers, bell mouth, tube ends and fixing accossories such as couplers lock nuts, saddles, pipe hook etccomplete all as specified and as directed.
206Supply and fixing in repair LED post top 40/45 watts complete with suitable size of GI pipe suitable size of required length duly grouted in existing locations including , PVC copper wire 1.5 sq mm 3 core of required lenght (upto 3 mtrs) complete all as specified and directed. Cat No. LLD0001542 of make : HALONIX or Cat No. LPTO-40-CDL-M of Make Crompton equivalent Bajaj
207Supply and fixing in repair LED bollard fitting 10wcomplete with suitable size of nuts/bolts for fixing arrangement and provision of suitable size PCC foundation for fixing of bollard fitting etc complete all as specified and direction by Engr-in-charge.Cat No. LBLSN-10-CDL of Make : Crompton or equivalent in Bajaj and Havells
Disclaimer :