Repair / Maintenance Of Misc E / M Service And Other Allied Works At 190 Mtn Bde, 190 Mtn Bde Sig Coy, Station Hq Tawang, 725 ( I ) Ad Pl Asc And 112 Engr Regt Under Ge Tawang, tawang-Arunachal Pradesh

Military Engineer Services-MES has published Repair / Maintenance Of Misc E / M Service And Other Allied Works At 190 Mtn Bde, 190 Mtn Bde Sig Coy, Station Hq Tawang, 725 ( I ) Ad Pl Asc And 112 Engr Regt Under Ge Tawang. Submission Date for this Tender is 30-06-2022. Electromechanical Services Tenders in tawang Arunachal Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

32600402
Corrigendum : Repair / Maintenance Of Misc E / M Service And Other Allied Works At 190 Mtn Bde, 190 Mtn Bde Sig Coy, Station Hq Tawang, 725 ( I ) Ad Pl Asc And 112 Engr Regt Under Ge Tawang
Open Tender
Indian
Arunachal Pradesh
tawang
30-06-2022

Tender Details

Repair / Maintenance Of Misc E / M Service And Other Allied Works At 190 Mtn Bde, 190 Mtn Bde Sig Coy, Station Hq Tawang, 725 ( I ) Ad Pl Asc And 112 Engr Regt Under Ge Tawang

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 10-Jun-2022 Amendment No. 1 BOQ 30-06-2022
2 15-Jun-2022 Amendment No. 2 BOQ 30-06-2022

Key Value

Document Fees
INR 500 /-
EMD
INR 28000.0 /-
Tender Value
INR 14 Lakhs /-

BOQ Items

NAME OF WORK :REPAIR / MAINTENANCE OF MISC E/M SERVICE AND OTHER ALLIED WORKS AT 190 MTN BDE, 190 MTN BDE SIG COY, STATION HQ TAWANG, 725 (I) AD PL ASC AND 112 ENGR REGT UNDER GE TAWANG
Sl. No. Item Description
1Dismantling and taking up or down old Unserviceable service cable and LT UG cable of any size complete all as specified and directed
2Supply and Laying and connecting with appropriate lugs in replacement XLPE LT cable PVC insulated,heavy duty electric cableswith Aluminum conductors,1100 volts grade, laid in trenches/on pole/in pipe /on wall ,using suitable clamps for fixing of cable complete all as specified and directed of cross-sectional area 10 Sqmm 2 Core.
3All as per Item No 2 above but 10 Sqmm 4 Core.
4All as per Item No 2 above but 25 Sqmm 3.5 Core.
5All as per Item No 2 above but 35 Sqmm 3.5 Core.
6Excavation in trenches, not exc 1.5m wide and not exc 1.5m in depth, for foundation, etc or for shafts, wells, cess-pits, menholes, pier holes, etc. not exc 10 sq m on plan and not exc 1.5m in depth and getting out in soft & loose soil complete all as specified and directed.
7Returning, filling in, including spreading, levelling, waterring and wall ramming in layers not exc 25 cm. for any type of soil complete all as specified and directed.
8Removing excavated soil not exc. 50 m and depositing where directed at a layers not exc 1.50 m. above/below the starting point complete all as specified and directed.
9Supply and laid in trenchesdouble walled corrugated HDPE pipes of inner dia 50 mm and outer dia 63 mm, as in cable protection work, complete all as specified and directed.
10Supply and fixingin replacement MCCB 4 Pole, 415 V,63 Amps with breaking capacity 25 KA complete with all accessories complete all as specified and directed.
11Materials and labour for earthing complete with galvanised steel earth plate electrode 60cmX60cmX6mm thick, burried directly in ground (earth pit not less than 2.25 metres deep below ground level)with top edge of the plate not less than 1.5 metres below normal groundlevel, connected to galvanised earth lead strip 32x6mm by means of volts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No-5 of SSR Part-I connected to earthing test point all as specified or indicated including excavation and connected earth work in hard/dense soil, PCC 1:3:6 type C-1 as in pit, 20mm dia GI pipe medium grade for watering pipe, 15 mm bore GI medium grade earth lead protection pipe, 50 mm thick RCC 1:2:4 type B-1 cover slab of earth pit reinforced with 8 mm dia TMT bars @ 10 cm C/C both ways and with handle made out of 10 mm dia bars, funnel, strainer,charcoal and testing on completion complete all as specified and directed.
12Materials and labour for replacement of GI pipe light grade with all fittings complete grouted in ground all as specified for 40 mm bore of pipe laid in trenches/fixed with poles/laid in road/plinth/floor for protection of cable complete all as specified and directed.
13Materials and labour for replacement GI pipe light grade with all fittings complete grouted in ground all as specified for 50 mm bore of pipe laid in trenches/fixed with poles/laid in road/plinth/floor for protection of cable complete all as specified and directed.
14Dismantling of old unserviceable steel poles of any size after disconnecting power, keeping aside serviceable insulators, stays, clamps etc for reuse complete all as specified and directed.
15Supply and fixingin replacement of steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP-22 (8.5 metres Long)complete all as specified and directed.
16Supply and fixing in repair LT Over over head line phase seperator of any size (2 way) in between distribution span of LT over head lines all as directed by the Engr-in-charge.
17Supply and fixing cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories, Outdoor type suitable for size 10 to 16 sqmm 3.5/4 Core.
18All as per Item No 17 above but 25 to 50 sqmm 3.5/ 4 Core.
19Materials and labour for cable route marker with route indication on cast iron disc of 100mm dia and 10mm thick, marked / written for "LT CABLE 1100 VOLTS" embosed including indicating direction fixed / bolted to 40mmx40mmx6mm thick MS angle iron support of 0.5m long embedded upto 200mm depth in concrete block of size 200mm x 200mm x 500mm of mix PCC 1:3:6, type C-1 including painting with two coats of synthetic enamel paint over a coat of red oxide primer to exposed steel surfaces complete all as specified and directed.
20Laying only old Precast concrete cable covers of Class LV type, Type 1, flat size 250mm x 150mm x 40mm complete all as specified and directed.
21Laying only old serviceable XLPE LT cable PVC insulated,heavy duty electric cableswith Aluminum conductors,1100 volts grade, laid in trenches/on pole/in pipe /on wall ,using suitable clamps for fixing of cable complete all as specified and directed of cross-sectional area 10 Sqmm 2 Core.
22All as per Item No 21 above but 16 Sqmm 2 Core.
23All as per Item No 21 above but 16 Sqmm 4 Core.
24All as per Item No 21 above but 25 Sqmm 4 Core.
25All as per Item No 21 above but 35 Sqmm 3.5 Core.
26Supply and fixing in repair aluminium lugs for 10 Sqmm size complete all as specified and directed.
27All as per Item No 26 above but 16 Sqmm.
28All as per Item No 26 above but 25 Sqmm.
29All as per Item No 26 above but 35 Sqmm.
30Locating electrical fault in UG cable of any size and repair by using of suitable size of cable lugs and straight through joint and make the good disturbed surfaces all as specified and directed by Engr-in-charge. Note :- Cable joint kit, Earth work & Aluminium lugswill be measured and paid seperately in respective items.
31Taking down carefully old rusted/brokenbracket with serviceable light fittings from the pole after disconnecting, supply and fix new bracket for street light fitting made out of32 mm dia light grade GI tubing bent to required shape 1.5m long including necessary GI clamps, nuts bolts and washers, refixing and connecting oldserviceable light fitting, fixing to the pole complete all as directed.
32Supply and fixing in repair weather proof hot press moulded SMC junction box / street light control box with side hinged door of size 250mm x 200 mm x 100 mm (approx) complete with hinged door locking arrangement and consisting of 2 Nos of suitable size cable glands consisting of 01 No panel mounted connector 4 pole MCB 6A10KA 01No, including connecting up with the electrical connections and fixing and clamping complete and all as directed
33Taking down unserviceable street light LED fitting/Flood light of any wattage and type from the pole/building of any height including disconnecting the cable connectionsfor repairing of light fittings and refixing in same position after repair and connecting all as specified anddirected. Note : (i)Spares shall be measured and paid seperatly under relevent items as supply only. (ii)The cost of replacing of internal connections, screws, bolts, minor spares etc.to make the fittings serviceable shall deemed to be included in the quoted cost.
34Supply only Electronic Driver for street light/Flood light fitting 25 to 50 Watts
35Supply and fix Electronic Driver for street light fitting/Flood light fitting60 to 100 watts
36Supply only LED platefor street light/Flood light fitting 25 to 50 Watts
37Supply and fix LED plate for street light fitting/Flood light fitting60 to 100 watts
38Taking down unserviceableLED Garden/Post top lantern/path light fitting of any wattage and typefrom existing position of any height including disconnecting the cable connectionsfor repairing of light fittings and refixing in same position after repair and connecting all as specified anddirected. Note : (i)Spares shall be measured and paid seperatly under relevent items as supply only.(ii)The cost of replacing of internal connections, screws, bolts, minor spares etc.to make the fittings serviceable shall deemed to be included in the quoted cost.
39Supply only Electronic Driver for Garden/Post top lantern/Path light fitting 5 to 15 Watts
40Supply only Electronic Driver for Garden/Post top lantern/Path light fitting 20 to 45 Watts
41Supply only LED plate for Garden/Post top lantern/Path light fitting 5 to 15 Watts
42Supply only LED plate for Garden/Post top lantern/Path light fitting 20 to 45 Watts
43Taking down unserviceable wiring and materials and labour for wiring for circuit/submain wiring with2 x 1.5 sq mm FRLS, PVC insulated copper conductor, single core cable alongwith earth wire 1.5 sqmm with the of FRLS is PVC insulated copper conductor, single core cable drawn through and including non metallic PVC rigid conduit(20mm dia)from junction box to street/flood light fitting on pole of any height as required all as specified and directed by Engr in charge. Note: Three runs of cable copper conductor and non metallic PVC conduit shall be measured as one unit length.
44Taking down unserviceable post top lantern and supply and fixingnew LEDpost top lanternfitting 40 watts on existing pipe of any size and height, IP 65 protection, spun aluminium landscape luminaire with high power LEDs as light source, clear cover for bright illumination, with all accessories prewired, fixed on poles completeall as directed(Make :HavellsCat part No RUBYPT40WLED757PSYMTOPCor equivalentof Philips/Bajaj/crompton)
45Taking down unserviceable garden light and supply and fixingnew LED garden light, 10 watt, sturdy IP 65 protection LED bollard with excellent light output through PMMA window ensuring maximum illumination aspect in sorrounding,fixed on existing base/pipe of any size and height with all accessories prewired fixed with suitable clamps, nuts, bolts etc. complete all as directed. (Make : Havells cat part No MOUNTBL10WLED830PSYMTOPMMA or equivelant of Philips/Bajaj/crompton)
46Taking down unserviceable flood light from poles/building and supply and fixing newLEDfloodlight fitting, 70 Wattintegral type light fixture, IP 66 protection, die cast aluminum body, reflector, drivers, LEDsand accessories with system wattage 70Watt complete all as directed. (Make :Havells Cat No: JETAALBAFLOODLIGHT70W or eequivelant of Philips/Bajaj/crompton)
47Taking down unserviceable flood light from poles/building and supply and fixing newLEDfloodlight fitting, 100 Wattintegral type light fixture, IP 66 protection, die cast aluminum body, reflector, drivers, LEDsand accessories with system wattage 100Watt complete all as directed.(Make :Havells Cat No: JETAALBAFLOODLIGHT100W or eequivelant of Philips/Bajaj/crompton)
48Taking down unserviceable street light from poles/building and supply and fixing new LED street light fittings 45 Watt ,environmental friendly long life, made up of pressure die cast aluminium housing with high power LED as lighting source with secondary optics and PC cover having top opening seperate driver compartment with IP66 protection and impact resistance of IK07.(Make : Cat Part No TRP-409-45-57-SL-NS-GL-NSG of Crompton or equivalent in Philips/Bajaj/Havells)
49All as per item No 48 here-in-before but of capacity 60 watts. (Make : Cat Part No TRP-409-60-57-SL-GL-NSG of Crompton or equivalent in Philips/Bajaj/Havells)
50All as per item No 48 here-in-before but of capacity 70 watts. (Make : Cat Part No TRP-409-70-57-SL-GL-NSG of Crompton or equivalent in Philips/Bajaj/Havells)
51Material & Labour for cutting the road/ hard standing for taking out/ laying pipe/cable, making good surface with PCC 1:3:6, TypeC-1,Using 20 mm graded stone aggregate afterlaying pipe/cable and removing the debrish to a distance n.exe 50mtr all as directed.
52Taking down unserviceable time switch with enclosureand supply and fixingnew time switches, Digital 24 hour, 440 V three phasewith contactor TP of rating 32 Amps and MCB TPN of rating 40A fitted in steel enclosure with necessary accessories to fixing on RCC/steel tubular pole including bracket, nuts, bolts, washers etc. and making all necessary connections through connectors complete all as specified and as directed. Make: Havells, Cat No: IHXTS03060 or equivalent in L&T/Legrand
53Taking down unserviceable time switch and supply and fixing new street light Time switches, Digital 24 hour, 440 V2 pole 32 Ampscomplete all as specified and as directed. Make: Havells cat part No DHTQB01016 or equivelant in Legrand/L&T
54Material and labour for two coats painting to LT steel tubular/RCC poles at the bottom from ground level towards upwards up to 2 m height with black and yellow strips each 15 cm width on the poles with synthetic enamel paint including preperation of old painted surface and marking of pole numbers with white synthetic enamel paint over black colour base as per existing pattern all as specified and directed .
55Materials and labour for framed work such as grills,gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors;ladders; framed balusters; walk ways; railings; framework of water tanks and similar work, steel conforming to Fe.290.Gde-E-165, complete all as specified and directed .
56Supply and fixing in repair PVC/HDPE water tank cover , threaded or hinged type as per existing cover suitable for 500/1000/2000 ltrs cap
57Materials and labour for carrying out "B" check comprising replacement of fuel filters,oil filters,air filter element,changing lubricating oil, cleaning of fuel lines,checking leakges if any, repair the leakge ,replacement of exhaust fan,gasket etc complete all as specified and directed for DG set 62.5 KVA ( KIRLOSKAR engine Model No.: HA694TCIG1) complete all as specified and directed.
58Labour and tools & plants required for identifyingfaultin the alternator of DG set 62.50 KVA by engaging technician from the authorised dealer of the company of manufacturer of DG set, replacing wornout spare parts to make the DG fully serviceable, testingand commitioning after reassembling complete withto and fro travelling charge of the technician, complete all as specified and directed. Note: (i) The cost of spare parts like AVR, Diode, rewinding of exciter field, exciter rotor etc will be measured and paid separately under respective items. (ii) The cost of bearing, grease, T & P, cotton for cleaning, wiring cables, soldering and other minor consumables will deemed to be included in the quoted rate.
59Supply onlyAVR (Model -R120) with functions to adjust generator output voltage for DG set of capacity 62.5 KVA, ,prevent voltage hunting,set under frequency,roll of knee point,set generator drop to 5% at full load,match AVR input to necessary output,set the over excitation cut off level ,set initial frequency ,related voltage dip,over voltage protection cut off level,max short circuit current with sensing input voltage range 170 - 250 V AC max,50-60 Hz frequency with out put max up to 120 V DC,continious current 2.7 A & transient 6 A for 10 second including necessary control wiring complete from alternator to AVR
60Materials and labour for transporting the exciter field of the DG set of capacity 62.5 KVA of any make and modeltonearest workshop (Guwahati/Tezpur) , dismantling carefully,rewinding the same with suitable size of copper wire, reassembling the same, testingfor smooth running for desired output voltage, returning back at Tawang,including taking down and refixing in position all as specified and directed by Engr in charge
61Materials and labour for transporting the exciter rotor of the DG set of capacity 62.5 KVA of any make and modeltonearest workshop (Guwahati/Tezpur) , dismantling carefully,rewinding the same with suitable size of copper wire, reassembling the same, testingfor smooth running for desired output voltage, returning back at Tawang, including taking down and refixing in position all as specified and directed by Engr in charge
62Supply and fixing in repair the unserviceable V belt of DG set capacity 62.5 KVA
63Materials and labour for disconnecting fuel pump from nozzle, disassembling fuel pump, taking out plunger, valves, bearing from pump assembly replacing the same and replacing O-rings, feed pump kit and copper washer, re-assembling all components, installing fuel pump, testing for satisfactory working of DG set.
64Supply and fixing in repair the unserviceable display controller (kg-934) with control wirirng for 62.5 KVA DG set of any make and model.
65Materials and labour for reconditioning of unserviceable battery of capacity 12 Volt 180 AH by replacing complete cells,PVC seperators,electrolyte,terminals and final sealing ,rechargeing battery and testing all as specified and directed.
66Materials and labour for replacing of SMF sealed battery of 12 volts 26 AH capacity for the UPS all as specified and directed.
67Materials and labour for repair of self starter after removing from the DG set of capacity 62.5 KVA of any make and model, rewinding of burnt out coil, replacing of contactors, complete cleaning, testing all as specified and directed.
68Materials and labour for repair of self starter after removing from the DG set of capacity 10 KVA of any make and model,rewinding of burnt out coil, replacing of contactors, complete cleaning, testing all as specified and directed.
69Materials and labour for repair of dynamo after removing from the DG set of capacity 62.5 KVA of any make and model,rewinding of burnt out coil, replacing of connecting terminals, complete cleaning, testing all as specified and directed.
70Materials and labour for repair of dynamo after removing from the DG set of capacity 10 KVA of any make and model,rewinding of burnt out coil, replacing of connecting terminals, complete cleaning, testing all as specified and directed.
71Supply and topping up of electrolyte for lead acid battery.
72Supply and topping up of distiled water for lead acid battery.
73Materials and labour for dismantling existing alternator model no.:LBS3K16L21587-H of kirloskar DG set of capacity 62.5 KVA and taking down existing diode assembly from exciter rotor and replacing the same with new diode assembly, reassembling and testingcomplete all as specified and directed.
74Materials and labour for repair/servicing of UPS of capacity upto 5 KVA by checking all electrical connection and rewiring the same, replacing wornout parts and refix the same location or directed by Engr in charge including testing,commissioning complete. Note:- (i) PCB kit and By pass switch etc will be measured and paid sepeartaly as supply only.(ii) Minor parts e.g nut, bolt, screw, wiring etc are included in quoted rate.
75Supply only PCB kit of UPS up to capacity of 5 KVA
76Sypply only bypass switch of UPS up to capacity of 5 KVA
77Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including4mm suspension wire, one twin core cable flat or circular of size 10 sqmm
78All as per item No 77 above but of size 6 sqmm
79Supply & replace the unserviceableC&S fuse, model-CDFL 00, rating-63 A for 62.5 KVA DG set all as specified and directed.
80Supply & replace the unserviceableC&S fuse, model-CDFL 00 holder for 62.5 KVA DG set all as specified and directed.