Repair / Maintenance Of Misc E / M Service And Other Allied Works At 40 Mtn Bde, Apnnb, 305 Fd Hosp, 24 Sikh, Ge Tawang, 277 Transit Camp, B Det, 106 Fd Wksp, 384 Coy Asc Sup, 72 Mfvh And 852 At Coy Under Ge Tawang, tawang-Arunachal Pradesh

Military Engineer Services-MES has published Repair / Maintenance Of Misc E / M Service And Other Allied Works At 40 Mtn Bde, Apnnb, 305 Fd Hosp, 24 Sikh, Ge Tawang, 277 Transit Camp, B Det, 106 Fd Wksp, 384 Coy Asc Sup, 72 Mfvh And 852 At Coy Under Ge Tawang. Submission Date for this Tender is 30-06-2022. Electrification Work Tenders in tawang Arunachal Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

32600367
Repair / Maintenance Of Misc E / M Service And Other Allied Works At 40 Mtn Bde, Apnnb, 305 Fd Hosp, 24 Sikh, Ge Tawang, 277 Transit Camp, B Det, 106 Fd Wksp, 384 Coy Asc Sup, 72 Mfvh And 852 At Coy Under Ge Tawang
Open Tender
Indian
Arunachal Pradesh
tawang
30-06-2022

Tender Details

Repair / Maintenance Of Misc E / M Service And Other Allied Works At 40 Mtn Bde, Apnnb, 305 Fd Hosp, 24 Sikh, Ge Tawang, 277 Transit Camp, B Det, 106 Fd Wksp, 384 Coy Asc Sup, 72 Mfvh And 852 At Coy Under Ge Tawang

Key Value

Document Fees
INR 500 /-
EMD
INR 34000.0 /-
Tender Value
INR 17 Lakhs /-

BOQ Items

NAME OF WORK :REPAIR / MAINTENANCE OF MISC E/M SERVICE AND OTHER ALLIED WORKS AT 40 MTN BDE, APNNB, 305 FD HOSP, 24 SIKH, GE TAWANG, 277 TRANSIT CAMP, B DET, 106 FD WKSP, 384 COY ASC SUP, 72 MFVH AND 852 AT COY UNDER GE TAWANG
Sl. No. Item Description
1Dismantling and taking up or down old Unserviceable service cable and LT UG cable of any size complete all as specified and directed
2Supply and Laying and connecting with appropriate lugs in replacement XLPE LT cable PVC insulated,heavy duty electric cableswith Aluminum conductors,1100 volts grade, laid in trenches/on pole/in pipe /on wall ,using suitable clamps for fixing of cable complete all as specified and directed of cross-sectional area 10 Sqmm 2 Core.
3All as per Item No 2 above but 10 Sqmm 4 Core.
4All as per Item No 2 above but 35 Sqmm 3.5 Core.
5All as per Item No 2 above but 50 Sqmm 3.5 Core.
6All as per Item No 2 above but 70 Sqmm 3.5 Core.
7Excavation in trenches, not exc 1.5m wide and not exc 1.5m in depth, for foundation, etc or for shafts, wells, cess-pits, menholes, pier holes, etc. not exc 10 sq m on plan and not exc 1.5m in depth and getting out in soft & loose soil complete all as specified and directed.
8Returning, filling in, including spreading, levelling, waterring and wall ramming in layers not exc 25 cm. for any type of soil complete all as specified and directed.
9Removing excavated soil not exc. 50 m and depositing where directed at a layers not exc 1.50 m. above/below the starting point complete all as specified and directed.
10Supply and laid in trenchesdouble walled corrugated HDPE pipes of inner dia 50 mm and outer dia 63 mm, as in cable protection work, complete all as specified and directed.
11Supply and laid in trenchesdouble walled corrugated HDPE pipes of inner dia 63 mm and outer dia 75 mm, as in cable protection work, complete all as specified and directed.
12Supply and fixingin replacement MCCB 4 Pole, 415 V,63 Amps with breaking capacity 25 KA complete with all accessories complete all as specified and directed.
13Supply and fixingin replacement MCCB 4 Pole, 415 V,100 Amps with breaking capacity 25 KA complete with all accessories complete all as specified and directed.
14Supply and fixingin replacement MCCB 4 Pole, 415 V,200 Amps with breaking capacity 25 KA complete with all accessories complete all as specified and directed.
15Materials and labour for earthing complete with galvanised steel earth plate electrode 60cmX60cmX6mm thick, burried directly in ground (earth pit not less than 2.25 metres deep below ground level)with top edge of the plate not less than 1.5 metres below normal groundlevel, connected to galvanised earth lead strip 32x6mm by means of volts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No-5 of SSR Part-I connected to earthing test point all as specified or indicated including excavation and connected earth work in hard/dense soil, PCC 1:3:6 type C-1 as in pit, 20mm dia GI pipe medium grade for watering pipe, 15 mm bore GI medium grade earth lead protection pipe, 50 mm thick RCC 1:2:4 type B-1 cover slab of earth pit reinforced with 8 mm dia TMT bars @ 10 cm C/C both ways and with handle made out of 10 mm dia bars, funnel, strainer,charcoal and testing on completion complete all as specified and directed.
16Materials and labour for replacement of GI pipe light grade with all fittings complete grouted in ground all as specified for 40 mm bore of pipe laid in trenches/fixed with poles/laid in road/plinth/floor for protection of cable complete all as specified and directed.
17Materials and labour for replacement GI pipe light grade with all fittings complete grouted in ground all as specified for 50 mm bore of pipe laid in trenches/fixed with poles/laid in road/plinth/floor for protection of cable complete all as specified and directed.
18Dismantling of old unserviceable steel poles of any size after disconnecting power, keeping aside serviceable insulators, stays, clamps etc for reuse complete all as specified and directed.
19Supply and fixingin replacement of steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP-22 (8.5 metres Long)complete all as specified and directed.
20M&L PCC (1:4:8) type D-2 using (40mm graded) stone aggregates as in foundation filling and mass concrete (for foundation bed concrete in stays /poles or any other directed site) complete all as specified and directed.
21M&L for PCC 1:3:6 type C-1 using (20 mm graded) broken stone aggregate as in mass concrete in coping of existing and new PCC/steel poles etc complete all as specified and directed.
22M&L for PCC 1:2:4 type B-1 using 20 mm graded broken stone aggregate as in mass concrete in coping of existing and new PCC/steel poles etc complete all as specified and directed.
23Supply and fixing in repair LT Over over head line phase seperator of any size (2 way) in between distribution span of LT over head lines all as directed by the Engr-in-charge.
24Supply and fixing cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories, Outdoor type suitable for size 10 to 16 sqmm 3.5/4 Core.
25All as per Item No 24 above but 25 to 50 sqmm 3.5/ 4 Core.
26Supply and laying or fixing or passing through pipe 1100 volts grade heavy duty cable PVC insulated stranded aluminium conductorserved with inner shethering of PVC tape armoured with galvanised steel wire or tape and overall PVC shetered 10 Sqm 2 Core nominal cross section in sevice connection including taking down old unserviceable service wire completeall as specified.
27Supply and laying or fixing or passing through pipe 1100 volts grade heavy duty cable PVC insulated stranded aluminium conductorserved with inner shethering of PVC tape armoured with galvanised steel wire or tape and overall PVC shetered 16 Sqm 2 Core nominal cross section in sevice connection including taking down old unserviceable service wire completeall as specified.
28Materials and labour for cable route marker with route indication on cast iron disc of 100mm dia and 10mm thick, marked / written for "LT CABLE 1100 VOLTS" embosed including indicating direction fixed / bolted to 40mmx40mmx6mm thick MS angle iron support of 0.5m long embedded upto 200mm depth in concrete block of size 200mm x 200mm x 500mm of mix PCC 1:3:6, type C-1 including painting with two coats of synthetic enamel paint over a coat of red oxide primer to exposed steel surfaces complete all as specified and directed.
29Laying only old Precast concrete cable covers of Class LV type, Type 1, flat size 250mm x 150mm x 40mm complete all as specified and directed.
30Laying only old serviceable XLPE LT cable PVC insulated,heavy duty electric cableswith Aluminum conductors,1100 volts grade, laid in trenches/on pole/in pipe /on wall ,using suitable clamps for fixing of cable complete all as specified and directed of cross-sectional area 10 Sqmm 2 Core.
31All as per Item No 30 above but 16 Sqmm 2 Core.
32All as per Item No 30 above but 16 Sqmm 4 Core.
33All as per Item No 30 above but 25 Sqmm 4 Core.
34All as per Item No 30 above but 35 Sqmm 3.5 Core.
35Supply and fixing in repair aluminium lugs for 10 Sqmm size complete all as specified and directed.
36All as per Item No 35 above but 16 Sqmm.
37All as per Item No 35 above but 35 Sqmm.
38All as per Item No 35 above but 50 Sqmm.
39All as per Item No 35 above but 70 Sqmm.
40Locating electrical fault in UG cable of any size and repair by using of suitable size of cable lugs and straight through joint and make the good disturbed surfaces all as specified and directed by Engr-in-charge. Note :- Cable joint kit, Earth work & Aluminium lugswill be measured and paid seperately in respective items.
41Taking down carefully old rusted/brokenbracket with serviceable light fittings from the pole after disconnecting, supply and fix new bracket for street light fitting made out of32 mm dia light grade GI tubing bent to required shape 1.5m long including necessary GI clamps, nuts bolts and washers, refixing and connecting oldserviceable light fitting, fixing to the pole complete all as directed.
42Supply and fixing in repair weather proof hot press moulded SMC junction box / street light control box with side hinged door of size 250mm x 200 mm x 100 mm (approx) complete with hinged door locking arrangement and consisting of 2 Nos of suitable size cable glands consisting of 01 No panel mounted connector 4 pole MCB 6A10KA 01No, including connecting up with the electrical connections and fixing and clamping complete and all as directed.
43Taking down unserviceable street light LED fitting/Flood light of any wattage and type from the pole/building of any height including disconnecting the cable connectionsfor repairing of light fittings and refixing in same position after repair and connecting all as specified anddirected. Note : (i)Spares shall be measured and paid seperatly under relevent items as supply only.(ii)The cost of replacing of internal connections, screws, bolts, minor spares etc.to make the fittings serviceable shall deemed to be included in the quoted cost.
44Supply only Electronic Driver for street light/Flood light fitting 25 to 50 Watts
45Supply and fix Electronic Driver for street light fitting/Flood light fitting60 to 100 watts.
46Supply only LED platefor street light/Flood light fitting 25 to 50 Watts.
47Supply and fix LED plate for street light fitting/Flood light fitting60 to 100 watts.
48Taking down unserviceableLED Garden/Post top lantern/path light fitting of any wattage and typefrom existing position of any height including disconnecting the cable connectionsfor repairing of light fittings and refixing in same position after repair and connecting all as specified anddirected. Note : (i)Spares shall be measured and paid seperatly under relevent items as supply only.(ii)The cost of replacing of internal connections, screws, bolts, minor spares etc.to make the fittings serviceable shall deemed to be included in the quoted cost.
49Supply only Electronic Driver for Garden/Post top lantern/Path light fitting 5 to 15 Watts
50Supply only Electronic Driver for Garden/Post top lantern/Path light fitting 20 to 45 Watts
51Supply only LED plate for Garden/Post top lantern/Path light fitting 5 to 15 Watts
52Supply only LED plate for Garden/Post top lantern/Path light fitting 20 to 45 Watts
53Taking down unserviceable wiring and materials and labour for wiring for circuit/submain wiring with2 x 1.5 sq mm FRLS, PVC insulated copper conductor, single core cable alongwith earth wire 1.5 sqmm with the of FRLS is PVC insulated copper conductor, single core cable drawn through and including non metallic PVC rigid conduit(20mm dia)from junction box to street/flood light fitting on pole of any height as required all as specified and directed by Engr in charge. Note:- Three runs of cable copper conductor and non metallic PVC conduit shall be measured as one unit length.
54Taking down unserviceable post top lantern and supply and fixingnew LEDpost top lanternfitting 40 watts on existing pipe of any size and height, IP 65 protection, spun aluminium landscape luminaire with high power LEDs as light source, clear cover for bright illumination, with all accessories prewired, fixed on poles completeall as directed. (Make :HavellsCat part No RUBYPT40WLED757PSYMTOPCor equivalentof Philips/Bajaj/crompton)
55Taking down unserviceable garden light and supply and fixingnew LED garden light, 10 watt, sturdy IP 65 protection LED bollard with excellent light output through PMMA window ensuring maximum illumination aspect in sorrounding,fixed on existing base/pipe of any size and height with all accessories prewired fixed with suitable clamps, nuts, bolts etc. complete all as directed.(Make : Havells cat part No MOUNTBL10WLED830PSYMTOPMMA or equivelant of Philips/Bajaj/crompton)
56Taking down unserviceable flood light from poles/building and supply and fixing newLEDfloodlight fitting, 70 Wattintegral type light fixture, IP 66 protection, die cast aluminum body, reflector, drivers, LEDsand accessories with system wattage 70Watt complete all as directed. (Make :Havells Cat No: JETAALBAFLOODLIGHT70W or eequivelant of Philips/Bajaj/crompton)
57Taking down unserviceable flood light from poles/building and supply and fixing newLEDfloodlight fitting, 100 Wattintegral type light fixture, IP 66 protection, die cast aluminum body, reflector, drivers, LEDsand accessories with system wattage 100Watt complete all as directed.(Make :Havells Cat No: JETAALBAFLOODLIGHT100W or eequivelant of Philips/Bajaj/crompton)
58Taking down unserviceable street light from poles/building and supply and fixing new LED street light fittings 45 Watt ,environmental friendly long life, made up of pressure die cast aluminium housing with high power LED as lighting source with secondary optics and PC cover having top opening seperate driver compartment with IP66 protection and impact resistance of IK07.(Make : Cat Part No TRP-409-45-57-SL-NS-GL-NSG of Crompton or equivalent in Philips/Bajaj/Havells)
59Material & Labour for cutting the road/ hard standing for taking out/ laying pipe/cable, making good surface with PCC 1:3:6, TypeC-1,Using 20 mm graded stone aggregate afterlaying pipe/cable and removing the debrish to a distance n.exe 50mtr all as directed.
60Taking down unserviceable time switch and supply and fixing new street light Time switches, Digital 24 hour, 440 V2 pole 32 Ampscomplete all as specified and as directed. (Make: Havells cat part No DHTQB01016 or equivelant in Legrand/L&T).
61Material and labour for two coats painting to LT steel tubular/RCC poles at the bottom from ground level towards upwards up to 2 m height with black and yellow strips each 15 cm width on the poles with synthetic enamel paint including preperation of old painted surface and marking of pole numbers with white synthetic enamel paint over black colour base as per existing pattern all as specified and directed .
62Supply and fix Off Load changeover switch side handle in sheet metal enclosure 415 V AC 50 Hz of Capacity 100 Amp 4 pole all as directed by the Engr-in-charge. Make-Havells,L&T or its equivalent.
63Supply and fix Off Load changeover switch side handle in sheet metal enclosure 415 V AC 50 Hz of Capacity 125 Amp 4 pole all as directed by the Engr-in-charge. Make-Havells,L&T or its equivalent.
64Supply and fix Off Load changeover switch side handle in sheet metal enclosure 415 V AC 50 Hz of Capacity 200 Amp 4 pole all as directed by the Engr-in-charge. Make-Havells,L&T or its equivalent.
65Materials and labour for framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors;ladders; framed balusters; walk ways; railings; framework of water tanks and similar work, steel conforming to Fe.290.Gde-E-165, complete all as specified and directed .
66Supply and fixing in repair PVC/HDPE water tank cover , threaded or hinged type as per existing cover suitable for 500/1000/2000 ltrs cap complete all as specified and directed.
67Materials and labour for carrying out "B" check comprising replacement of fuel filters, oil filters, air filter element, changing lubricating oil, cleaning of fuel lines, checking leakges if any, repair the leakge, replacement of exhaust fan, gasket etc complete all as specified and directed for DG set 125 KVA.
68Materials and labour for carrying out "B" check comprising replacement of fuel filters,oil filters,air filter element,changing lubricating oil,cleaning of fuel lines, checking leakges if any, repair the leakge ,replacement of exhaust fan,gasket etc complete all as specified and directed for DG set 10 KVA complete all as specified and directed.
69Materials and labour for dismantling existing alternator of DG set of capacity 125 KVA and taking down existing diode assembly from exciter rotor and replacing the same with new diode assembly, reassembling and testingcomplete all as specified and directed.
70Materials and labour for dismantling existing alternator of DG set of capacity 10 KVA and taking down existing diode assembly from exciter rotor and replacing the same with new diode assembly, reassembling and testingcomplete all as specified and directed.
71Supply and fixing in repair the unserviceable V belt of DG set capacity 10 KVA.
72Supply and fixing in repair the unserviceable V belt of DG set capacity 125 KVA.
73Supply and fixing in repairAVR (Model -R120) with functions to adjust generator output voltage for DG set of capacity 125 KVA, ,prevent voltage hunting,set under frequency,roll of knee point,set generator drop to 5% at full load,match AVR input to necessary output,set the over excitation cut off level ,set initial frequency, related voltage dip,over voltage protection cut off level,max short circuit current with sensing input voltage range 170 - 250 V AC max,50-60 Hz frequency with out put max up to 120 V DC,continious current 2.7 A & transient 6 A for 10 second including necessary control wiring complete from alternator to AVR
74Supply and fixing in repairAVR (Model -R120) with functions to adjust generator output voltage for DG set of capacity 10 KVA, ,prevent voltage hunting,set under frequency,roll of knee point,set generator drop to 5% at full load,match AVR input to necessary output,set the over excitation cut off level ,set initial frequency, related voltage dip,over voltage protection cut off level,max short circuit current with sensing input voltage range 170 - 250 V AC max,50-60 Hz frequency with out put max up to 120 V DC,continious current 2.7 A & transient 6 A for 10 second including necessary control wiring complete from alternator to AVR
75Materials and labour for transporting the exciter rotor of the DG set of capacity 125 KVA of any make and modeltonearest workshop (Guwahati/Tezpur) , dismantling carefully,rewinding the same with suitable size of copper wire, reassembling the same, testingfor smooth running for desired output voltage, returning back at Tawang,including taking down and refixing in position all as specified and directed by Engr in charge
76Materials and labour for transporting the exciter rotor of the DG set of capacity 10 KVA of any make and modeltonearest workshop (Guwahati/Tezpur) , dismantling carefully,rewinding the same with suitable size of copper wire, reassembling the same, testingfor smooth running for desired output voltage, returning back at Tawang, including taking down and refixing in positionall as specified and directed by Engr in charge
77Materials and labour for reconditioning of unserviceable battery of capacity 12 Volt 180 AH by replacing complete cells, PVC seperators,electrolyte,terminals and final sealing ,rechargeing battery and testing all as specified and directed.
78Materials and labour for replacing of SMF sealed battery of 12 volts 26 AH capacity for the UPS all as specified and directed.
79Materials and labour for repair of self starter after removing from the DG set of capacity 125 KVA of any make and model, rewinding of burnt out coil, replacing of contactors, complete cleaning, testing all as specified and directed.
80Materials and labour for repair of self starter after removing from the DG set of capacity 10 KVA of any make and model,rewinding of burnt out coil, replacing of contactors, complete cleaning, testing all as specified and directed.
81Materials and labour for repair of dynamo after removing from the DG set of capacity 125 KVA of any make and model,rewinding of burnt out coil, replacing of connecting terminals, complete cleaning, testing all as specified and directed.
82Materials and labour for repair of dynamo after removing from the DG set of capacity 10 KVA of any make and model,rewinding of burnt out coil, replacing of connecting terminals, complete cleaning, testing all as specified and directed.
83Supply and topping up of electrolyte for lead acid battery.
84Supply and topping up of distiled water for lead acid battery.
85Materials and labour for repair/servicing of UPS of capacity upto 5 KVA by checking all electrical connection and rewiring the same, replacing wornout parts and refix the same location or directed by Engr in charge including testing, commissioning complete. Note:- (i) PCB kit and By pass switch etc will be measured and paid sepeartaly as supply only.(ii) Minor parts e.g nut, bolt, screw, wiring etc are included in quoted rate.
86Supply only PCB kit of UPS up to capacity of 5 KVA
87Sypply only bypass switch of UPS up to capacity of 5 KVA
88Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including4mm suspension wire, one twin core cable flat or circular of size 10 sqmm.
89All as per item No 88 above but of size 6 sqmm.
90Materials and labour for GI Strip of size 32x6m as earth continuuty conductor burried in ground or drawn in pipe or fixed to wall on saddle complete all as specified and directed.
Disclaimer :