Drinking Water Supply and Sanitation Government Departments Closing in 0 days TDR #32582260

Commissioning Of Tw Drilled By Departmental Rig Including Supply And Installation Of Energy Efficient Submersible Pump Sets, Panels Cables And Other Allied Works And Connections With Existing System With 24 Months Defect Liability Period Commissioning Of

Issued by Government Departments · didwana, Rajasthan
Tender Value
29.61 Lakhs
Estimated cost
Bid Submission
14 Jun 2022
0 days left
EMD
59220
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
didwana → Rajasthan
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Commissioning Of Tw Drilled By Departmental Rig Including Supply And Installation Of Energy Efficient Submersible Pump Sets, Panels Cables And Other Allied Works And Connections With Existing System With 24 Months Defect Liability Period Commissioning Of Tw Drilled

BOQ

Name of Work: Commissioningofbore hole by DTH/Rotary/ Combination rig of 200 mm dia, supply and installation of energy efficient Submersible Pump sets, PanelsCables and other allied works including commissioning and testing of tube well under PHED Div. DIDWANA with 24 months defect liability, 3 years operation and maintenance after completion of defect liability period
Sl. No. Item Description
1Sub Div. Didwana
2Supply & Installation of 3 phase ISI marked submersible motor pump set ofthree star or better rating of BEEand as per IS: 8034-2018 (pump) and IS 9283-2013 (motor) or as amended up to date of approved make of following duty condition with required accessories including making connection suitable for tube well/DCB. The job includes lowering of motor pump, installation of complete fitting & accessories, jointing of electrical cables up to switch board, testing of submersible pump set and interconnection up to water mains, complete in all respect.
3Up to 5.5 KW (7.5 HP) & head above 120 mtr. ( 3 SETS)
47.5 KW (10 HP) & head above 120 mtr.( 6 SETS)
59.3KW (12.5 HP) & head above 120 mtr. ( 4 SETS)
613 KW (17.5 HP) & head above 120 mtr. ( 1 SETS)
7Supply & Fixing of ISI marked three core PVC flat submersible cableas per IS 694:1990 or amended up to date and conductor as per class 5 of IS 8130:1980including making connection etc.
83 core 6.0 Sq.mm
9Providing & Lowering in tube well ISI marked GI Pipe medium duty (“B\" class), Steel tube as per IS:1239 or amended up to date and zinc coating as per IS 4736, threaded and double flanged (welded) on both ends and two number25x3mm MS flat welded on both ends between pipe & flange, rubber washer & nut bolts etc. complete in all respect.
1050 mm dia
11Supply and Fixing of electric control feeder panel comprising of suitable rating MCCB , fully automatic star-delta starter, over load relay,ampere meter with CTs, volt meter, phase preventer, suitable starting capacitors, phase indicators, lighting arrangement etc. complete suitable for three phase pump set. The panel should have space for energy meter ( supplied by DISCOM).All these equipments shall be housed by panel box made out from 18 gauge M.S. Sheet with powder coating. Panel should be ofminimum size 900 x 600 x 450 mm with Stand ( made of angle iron of size 35x35x5mm) duly bolted/screwed with enclosure box having 4 legs, each leg’s length 18\" and double door including in built locking system.The legs should be embedded in M-15 cement concrete plat form. The size of CC platform should be equal or bigger than the base size of panel having height of at least 200 mm from ground level. The panel should have opening of suitable size in front of space for energy meter with glass for meter reading. The operation of panel should be suitable for on 440 Volt AC Supply.
12Above 5 HP and up to 10 HP
13Above 10 HP and up to 15 HP
14Sub Div. Ladnun
15Supply & Installation of 3 phase ISI marked submersible motor pump set ofthree star or better rating of BEEand as per IS: 8034-2018 (pump) and IS 9283-2013 (motor) or as amended up to date of approved make of following duty condition with required accessories including making connection suitable for tube well/DCB. The job includes lowering of motor pump, installation of complete fitting & accessories, jointing of electrical cables up to switch board, testing of submersible pump set and interconnection up to water mains, complete in all respect.
167.5 KW (10 HP) & head above 120 mtr.( 2 SETS)
179.3KW (12.5 HP) & head above 120 mtr. ( 2 SETS)
1813 KW (17.5 HP) & head above 120 mtr. ( 2 SETS)
19Supply & Fixing of ISI marked three core PVC flat submersible cableas per IS 694:1990 or amended up to date and conductor as per class 5 of IS 8130:1980including making connection etc.
203 core 6.0 Sq.mm
21Providing & Lowering in tube well ISI marked GI Pipe medium duty (“B\" class), Steel tube as per IS:1239 or amended up to date and zinc coating as per IS 4736, threaded and double flanged (welded) on both ends and two number25x3mm MS flat welded on both ends between pipe & flange, rubber washer & nut bolts etc. complete in all respect.
2250 mm dia
23Supply and Fixing of electric control feeder panel comprising of suitable rating MCCB , fully automatic star-delta starter, over load relay,ampere meter with CTs, volt meter, phase preventer, suitable starting capacitors, phase indicators, lighting arrangement etc. complete suitable for three phase pump set. The panel should have space for energy meter ( supplied by DISCOM).All these equipments shall be housed by panel box made out from 18 gauge M.S. Sheet with powder coating. Panel should be ofminimum size 900 x 600 x 450 mm with Stand ( made of angle iron of size 35x35x5mm) duly bolted/screwed with enclosure box having 4 legs, each leg’s length 18\" and double door including in built locking system.The legs should be embedded in M-15 cement concrete plat form. The size of CC platform should be equal or bigger than the base size of panel having height of at least 200 mm from ground level. The panel should have opening of suitable size in front of space for energy meter with glass for meter reading. The operation of panel should be suitable for on 440 Volt AC Supply.
24Above 10 HP and up to 15 HP
25Above 15 HP and up to 20 HP

AI Tender Summary

OUR REF NO 32582260
AUTHORITY Government Departments
TENDER VALUE 29.61 Lakhs
LAST DATE 14-06-2022
Authority
Authority Name Public Health Engineering Department
Work Description Commissioning Of Tw Drilled By Departmental Rig Including Supply And Installation Of Energy Efficient Submersible Pump Sets, Panels Cables And Other Allied Works And Connections With Existing System With 24 Months Defect Liability Period Commissioning Of Tw Drilled
Basic Detail
Tender No NIT NO 26/2022-23
Bidding Type Tender
Location
City didwana
State Rajasthan
Key Dates
Publish Date 08 Jun 2022
Submission Date 14 Jun 2022
Open Date 15 Jun 2022
Finance
Tender Value 29.61 Lakhs
Tender Fee 1000
EMD 59220
Exemption Not Available
Document List
3212f587-bad7-4f05-bacf-65ee01027d8e.html
26comm.pdf
BOQ_496606.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jun 08, 2022
11:30 IST

Tender Published

Tender notice published.

Completed
Jun 14, 2022
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Jun 15, 2022

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

3212f587-bad7-4f05-bacf-65ee01027d8e.html

pdf

26comm.pdf

xls

BOQ_496606.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders