BOQ
| Sl. No. | Item Description |
| 1 | Supply, erection testing and commissioning of high mast lighting system (as per CP3-TRT/1996 of ILE, UK) consisting of totally hot dip galvanised by single dipped method high mast, lantern carriage suitable for up to 12 nos luminaries, mast head assembly, two nos aviation obstruction neon lights, double drum type self sustaining winch, integral power tool( winch motor with control circuit) hot dipped galvanised heavy duty pipe lightening finial, suitable ropes and CC foundation of M-15 grade complete as required. The mast is constructed from mild steel plates (as per BS-EN 10025) cut and folded to form a polygonal section, telescopic jointed and welding as per BS 5135. The complete work shall be supervised and certified by the manufacturers for satisfactory supply, erection, testing and commissioning of high mast. with all accessories, which also includs internal electrical cable and panel with foundation, erection & commissioning excluding luminaries and lamps (Group-l) 16 Mtr HM (in 2 section) |
| 2 | Providing & Laying XLPE insulated / P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor Armoured of IS:7098-I/1554-1 approved make in ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick under layer of sand, second Class bricks covering, refilling earth, compaction of earth, making necessary connection, testing etc. as required of size. 2.5 Sq. mm,2 Core |
| 3 | Maintenance free gel earthing with pipe in pipe /Strip in Pipe technology filled with anti corrosive conductive compound (CPRI tested) below the ground in 150 -200 mm dia earth pit and surrounding filled with required mineral filling compound (MFC should have hygroscopic proper ty to retain the moisture for long time to create low resistance Zone) and C.C. finished chamber covered with hinge type with locking arrangement C.I cover. C.I. frame of size 300mm x300mm complete testing of earth resistance as required of following sizes With pipe in pipe technology (inner pipe dia / outer pipe dia) 80 -100 micron G.I. coating |
| 4 | S & Laying following size earth wire/strip in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, making connection etc. as required.25mm x 3mm GI strip |
| 5 | Providing & Laying XLPE insulated / P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor Armoured of IS:7098-I/1554-1 approved make in ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick under layer of sand, second Class bricks covering, refilling earth, compaction of earth, making necessary connection, testing etc. |
| 6 | S & Laying following size\" A\" class G.I. Pipe with accessories for laying earth conductor/strip in ground/surface/recess as required |
| 7 | P/ F IP-65/ IP-66 protected street light luminaries on existing bracket. Fixture made from powder coated single piece pressure die cast aluminum housing with heat dissipation fins on housing with high power LEDs . Diffuser / glass cover for ensuring IP-65 protection for lamp and control gear compartment, system lumen output of 100 lum/watt high power LED. Integrated driver shall be high efficiency having efficiency more than 85 % and in compliance to IEC standards. System life of 50000 burning hours with 70 % of initial lumens aintained. Fixture shall be in CE compliance. high power Led Flood Light 240 watt |
| 8 | P & F of IP 55 protected light controlled switch based on infrared sensing and daylight with built in over load protection, timer to switch OFF at preselected time. Switch shall have 7 day power backup without hampering of preset time and over ride facility for maintenance purpose Suitable for 15 kw load (three phase) including contactor, MCB, cable glands, terminal block and locking arrangement |
| 9 | Providing, lowering, laying, aligning, fixing in position and jointing at all level/ depths full round HDPE DWC (double wall corrugated) pipes of SN8 grade as per IS 16098 (Part 2) amended upto date in trenches in complete including all material, labour, sectional hydro testing (including the cost and conveyance of water to site for testing) and commissioning as per Technical |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-2 Issued
Clarifications on tender conditions and amendments issued.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender