| Sl. No. | Item Description |
| 1 | Wiring for light point / fanpoint /exhaust fan /call bell point with 1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit and earthing the light point with 1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable as required. Make:-KEI,Anchor,L&T )Legrand (Myrius),L&T(Oris),Anchor(Roma plus) |
| 2 | Group C. |
| 3 | Wiring for twin control light point with 1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit with 2-way, 5/6 amps. piano type switch and earthing the light point with 1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable as required. Make:-KEI,Anchor,L&T )Legrand (Myrius),L&T(Oris),Anchor(Roma plus) |
| 4 | Group C. |
| 5 | Wiring for light plug with 2x1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 1 No.1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable for earthing as required. |
| 6 | Wiring for circuit/sub-main with following size PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 1 No.HRFRLS/PVC insulated single core copper conductor cable of same size for earthing as required. Make:- KEI/SCI/Havells/Plaza |
| 7 | 2x1.5 Sq. mm. |
| 8 | 2x10 Sq. mm. |
| 9 | Wiring for circuit / sub-main with 4x16 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC conduit along with 2 No.16 Sq.mm. (4x16+2x16) HRFRLS/PVC insulated single core copper conductor cable for earthing as required. Make:- KEI/SCI/Havells/Plaza |
| 10 | Wiring for power plug with 2x4 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 1 No.4 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable for earthing as required. Make:- KEI/SCI/Havells/Plaza |
| 11 | Wiring for power plug with 4x4 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 2 No.4 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable for earthing as required. Make:- KEI/SCI/Havells/Plaza |
| 12 | Supplying and fixing of following sizes of steel conduit along with the accessories in surface / recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required:- Make: Diplast/BEC/Finolex |
| 13 | 25 mm. dia |
| 14 | Supplying and fixing of following sizes of PVC conduit along with the accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required:- Make: Diplast/BEC/Finolex |
| 15 | 50 mm. dia |
| 16 | Supplying and drawing following size of PVC insulated, heat resistant, flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in existing surface / recessed, Steel/PVC conduit as required. Make:- KEI/SCI/Havells/Plaza |
| 17 | 3x1.5 Sq. mm. |
| 18 | Supplying and fixing bakelite batten/angle holder including connections etc. as required:- |
| 19 | Supplyinganderection of 6amps. to 32 amps. rating, 10 KA breaking capacity, 240volts, \"C\" curves, miniaturecircuit breaker of following poles in the existing MCB DB complete with connections etc. as required:- Makes:- L&T/Legrand/Schneider. |
| 20 | Single pole. Cat-A. |
| 21 | Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. Makes:- L&T/Legrand/Schneider. |
| 22 | 63 Amps. Cat-A. |
| 23 | Supplying and fixing following rating, double pole (single phase & neutral) 240 volts, residual current circuit breaker (RCCB), having a sensitivity current up to 300 miliampers in the existing MCB DB complete with connections, testing and commissioning etc. as required. Makes:- L&T/Legrand/Schneider. |
| 24 | 63 Amps. Cat-A. |
| 25 | Supplyingand fixingoffollowingway, singlepoleandneutral sheetsteel MCB distribution board, 240 volts, on surface / recess, complete with tinned copper bus- bar, wire-set, neutral link, earth bar, din-bar, detachable gland plate, blanking plate, cable, identification labels interconnections, phosphatized and powder painted, including earthing etc. as required:- Makes:- L&T/Legrand/Schneider. |
| 26 | Double door-4 way |
| 27 | Double door-12 way |
| 28 | Double door-16 way |
| 29 | Earthing with G.Iearth pipe 4.5 mtr. long and 40mm dia, including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. ( but without charcoal or coke and salt ) complete as required. |
| 30 | Extra for using salt and charcoal for pipe earth electrode complete as required. |
| 31 | Supplying and laying 6 SWG G.I. wire at 0.50 mtr. below ground level for earth electrode conductor, including soldering etc. as required. |
| 32 | Providing, Installation, testing and commissioning of ceiling fan with regulator, including wiring the down rods of standard length (up to 30 cm) with 16/0.20 mm twin twisted flexible, cotton braided, copper cable, including providing and fixing phenolic laminated sheet cover on the fan boxand earthing etc. as required:- |
| 33 | Ceiling Fan 1200 mm sweep, Category-A (Make: Usha Energia ISI)/Equivalent |
| 34 | Supplying and fixing of LED Mirror Light having luminous flux 450 lumens, Beam angle 120 degree, color 5700 K, i.e. Power factor > 0.9 , Harmonic dlstortion < 10% and efftcacy> 100 lumens per watt, CRI rating>80, sultable for lnput voltage AC 220-240v, 50/60 HZ complete with all accesseries, including connections, testing and commissioning etc.as required complete in all respect Make: Bajaj, Philips, Jaquar, Havells, Panasonic. |
| 35 | Mirror light 5 watt (Make: Bajaj, Cat No. BCLSB 05 WH)/Equivalent |
| 36 | Providing and installation of exhaust fan of following sizes in the existing opening, including making the hole to suit the size of the above fan, making good the damages, connections, testing and commissioning etc. as required:- Makes:- Usha/Bajaj/Crompton/Recold |
| 37 | Exhaust Fan, Light duty, (Domestic) 300 mm sweep |
| 38 | Providing and installation of following type of Square type surface mounted LED Downlight luminaire CCT(K)- 6000 white power coated CRCA housingdiffusser to avoid glaire with spectfcationsi.e. Power factor > 0.9, Harmonic distortion < 10% and efftcacy > 100 lumens per watt, CRI rating>80 sultable for input voltage AC 220-240V, 50/60 HZ complete with all accesseries, including connections, testing and commissioning etc. as required complete in all respects. Make: Panasonic, Bajaj, Jaquar or any other as approved by Engineer-in-Charge. |
| 39 | LED Downlighter 15 watt(Camber Modan) (at par with Panasonic cat no. PDLM11156BS)/ Equivalent |
| 40 | Providing and installation of following type of Surface mounting Rectangular type LED panel light luminaire 3600 lumens CCT(K)- 5700 with specificationsi.e. Power factor > 0.9 , Harmonic Distortion < 10% and efficacy > 100 lumens per watt, CRI rating>80, suitable for input voltage: AC 220-240 V, 50/60 HZ complete with all accessories, including connections, testing and commissioning etc. as required complete in all respects. Make: Panasonic/Jaquar/Bajajor any other as approved by Engineer-in-Charge. |
| 41 | LED Panel Light 36 watt 1\"x4\", (Make: Panasonic Cat no PBLM 15368, 5700K/ Equivalent |
| 42 | Supplying & fixingfollowing type of Surface mounted luminaires, white power coated CRCA housingdiffusser to avoid glaire,it should be compatible with specification i.e. Power Factor > 0.9, Harmonic Distortion < 10%and efficacy > 100 Lumens per watt, CRI rating> 80 suitable for input voltage: AC 220-240 V, 50 Hz,complete with all accessories, connections, testing and commissioning etc. as required. Make: Panasonic, Bajaj, Jaquar or any other approved by Engineer-in-charge. |
| 43 | LED Batten 20W,4 feet long(Make: Panasonic, Cat no.PBTM 08208)/ Equivalent |
| 44 | Supplying and fixing metal box of 100mmx100mmx60mm deep (nominal size) on surface/recess with suitable size phenolic laminated sheet cover in the front including providing and fixing 5 pin 5/6 amps socket outlet and 5/6 amps, piano type switch, connections, painting etc. as required. Makes:- Legrand(Myrius),L&T(Oris),Anchor Roma(Plus). |
| 45 | Supplying and fixing metal box of 180mmx100mmx60mm deep (nominal size) on surface/recess with suitable size phenolic laminated sheet cover in the front including providing and fixing 6 pin 15/16 amps socket outlet and 15/16 amps, piano type switch, connections, painting etc. as required. Makes:- Legrand(Myrius),L&T(Oris),Anchor Roma(Plus). |
| 46 | Providing and fixing of LED 20 watt street light luminaries of Panasonic having cat No. /ordering code PSTM 27208, powder coated pressure die-cast aliminium heat sink and toughened glass SMDLED streetlight with heat resistant toughened glass it should be compatible with specification i.e. power factor = 0.9, Harmonic Distortion < 20% and efficacy = 100 Lumens per watt, CRI rating> 70 suitable for input voltage: AC 220-240 V, 50 Hz, complete with all accessories, connections, testing and commisioning etc. as required. Make:- Panasonic, Philips, Bajaj, Jaquar or any other approved by Engineer-In-Charge. |
| 47 | Street light fixture 20 watt LED with Lens , Make Panasonic (Cat No. PSTM 27208) , 5700K/ Equivalent |
| 48 | Supplying and erection of street light bracket made of G.I. pipe \"A\" class of suitable length and dia, the pipe bended to give an angle of 100 to 110 degree fitted with bolt & nuts at the top of existing pole or wall including painting the pipe with two coats of approved paint over priming coat complete in all respects as required:- |
| 49 | 40 mm dia. G.I. pipe, heavy class |
| 50 | Providing and fixing following rating and breaking capacity MCCB in the existing cubical panel board including drilling holes in the cubicle panel, making connections, etc. as required. Make: L&T, Schneider, Siemens, ABB, C&S, Standard or any other equivalent make approved by Engineer-in-Charge. |
| 51 | MCCB 63A, 4P, 10 KA (Make: L&T, Cat No. EM90984OOHO/ Equivalent |
| 52 | Providing and fixing Size I Enclosure for DY125U MCCBs suitable for 3Pole & 4Pole MCCBs etc. as required. Make: L&T, Schneider, Siemens, ABB, C&S, Standard or any other equivalent makeapproved by Engineer-in- Charge. |
| 53 | Enclosure Size-I (Make: L&T, Cat No. CM90996OOOO)/Equivalent |
| 54 | Supplying and fixing sheet metal bus-bar chamber suitable for 63 Amp. 415 volts capacitywith 4 No. copper strip bus-bars each of length 300mm & cross-sectional area (16mmx3.17mm), enclosure made from 1.6 mm thick M.S. sheet having overall dimensions (380mmx350mmx150mm) nominal with all accessories including connections, earthing the body etc. as required:- |
| 55 | Supplying and erection ofwall mounted metal boards for switch gear mounting of suitable size, with permissible variation in size of plus minus 5mm, welded frame work madeof M.S. angle iron (50 mm x 50 mm x 6 mm thick) with sufficient numbers of horizontal and vertical intermediate members (25mm x 6mm thick) flat iron including painting and bonding to the existing earth as required:- |
| 56 | Supplying and fixing electrical switch board, having 4 Nos. of 5 amp. switches and sockets on suitable size of metal box of 200mm X250mm X100mm deep (nominal size) on surface or in recess with suitable size phenolic laminated sheet cover in the front i/c providing and fixing 4 No. 5 pin 5/6 amp. socket outlet and 5/6 amp piano type switch, connection, painting etc. as required. |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender