Repairs / Maintenance Of Dg Sets Of Various Rating And Solar Battery Light At Chakabama Military Station Under Age ( I ) Zakhama., zakhama-Nagaland

Military Engineer Services-MES has published Repairs / Maintenance Of Dg Sets Of Various Rating And Solar Battery Light At Chakabama Military Station Under Age ( I ) Zakhama.. Submission Date for this Tender is 04-07-2022. Dry Cell Batteries Tenders in zakhama Nagaland. Bidders can get complete Tender details and download the document.




Tender Notice

32556124
Corrigendum : Repairs / Maintenance Of Dg Sets Of Various Rating And Solar Battery Light At Chakabama Military Station Under Age ( I ) Zakhama.
Open Tender
Indian
Nagaland
zakhama
04-07-2022

Tender Details

Repairs / Maintenance Of Dg Sets Of Various Rating And Solar Battery Light At Chakabama Military Station Under Age ( I ) Zakhama.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 27-Jun-2022 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 04-07-2022

Key Value

Document Fees
INR 500 /-
EMD
INR 19000.0 /-
Tender Value
Refer document

BOQ Items

NAME OF WORK : REPAIRS/MAINTENANCE OF DG SETS OF VARIOUS RATING AND SOLAR BATTERYLIGHT AT CHAKABAMAMILITARY STATION UNDER AGE(I) ZAKHAMA.
Sl. No. Item Description
1Material and Labour for ‘B’ check servicing all as per manufacturer instructions, includingcost of following ‘B’ check spares and minor spares required for carrying out the check like nut, bolts, washers,gaskets, screws, hose clamps, including draining out old engine oil and filling in new engine oil, filling in/top up coolant in radiators of water cooled engine, taking out air filter element cleaning the same with compressed air for the removing the dust or replace unserviceable element with new element, cleaning of waste oil or coolant from engine and near by spare parts of engine of make Kirloskar/Cummins and Alternator of capacity 62.5 KVA, installed at Main Receiving Stationat ChakabamaMilitary Station, complete testing after repair for its smooth functioning :- (a)Lubricating oil filter Kirlosakar- 01 Nos (b)Fuel filter Kirloskar- 02 Nos (c)Minor spares and waste cotton for cleaning - 01 Kit Note :1.Quoted rated deems to be included fuel filter kits and lubricating oil filter kits and minor spares required for check. 2.Engine oil, Coolant for radiator, distilled water, new air filter element and spares parts shall be measured and paid separately under relevant item of this schedule.
2Supply only Air filter elementinnersuitable for DG set Engine of make Kirlosakar and capacity62.5 KVA.
3Supply only Air filter elementoutersuitable for DG set Engine of make Kirlosakar and capacity62.5 KVA.
4Supply only engine oil Kirloskar Super engine oil grade 20W40 against "B" check servicing and as per the capacity of engine model and as per manufacturers recommendation complete all as directed.
5Supply and fix in repairs,Radiator hosesuitable for DG set Engine of make Kirlosakar and capacity62.5 KVA.
6Supply and fix in repairs,Cooler hose suitable for DG set Engine of make Kirlosakar and capacity62.5 KVA.
7Supply and fix in repairs,water pump suitable for DG set Engine of make Kirlosakar and capacity62.5 KVA.
8Supply and fix in repairs,Thermostate switch suitable for DG set Engine of make Kirlosakar and capacity62.5 KVA.
9Supply and fix in repairs,Screen Filtersuitable for DG set Engine of make Kirlosakar and capacity62.5 KVA.
10Supply and fix in repairs,Diesel filtersuitable for DG set Engine of make Kirlosakar and capacity62.5 KVA.
11Supply and fix in repairs,Bypass filtersuitable for DG set Engine of make Kirlosakar and capacity62.5 KVA.
12Supply and fix in repairs,V belt suitable for DG set Engine of make Kirlosakar and capacity62.5 KVA.
13Supply and fix in repairs,Dynamo belt suitable for DG set Engine of make Kirlosakar and capacity62.5 KVA.
14Supply and fix in repairs,Lube oil cooler suitable for DG set Engine of make Kirlosakar and capacity62.5 KVA Lube oil cooler
15Supply and fix in repairs, Turbo chargerDG set Engine of make Kirlosakar and capacity62.5 KVA.
16All as per item No 01 here-in- before but make of alternator and Engine is Kirloskar and capacity, 125 KVA installed atPump House No 2 and 3at ChakabamaMilitaryStation. (a)Lubricating oil filter Kirlosakar- 02 Nos (b)Fuel filter Kirloskar Part No- 02 Nos (c)Minor spares and waste cotton for cleaning - 01 Kit Note :1.Quoted rated deems to be included fuel filter kits and lubricating oil filter kits and minor spares required for check. 2.Engine oil, Coolant for radiator, distilled water, new air filter element and spares parts shall be measured and paid separately under relevant item of this schedule.
17Supply only Air filter element inner and oute for 125 KVA DG set.
18Supply and fix in repairs,Diesel filtersuitable for DG set Engine of make Kirloskar/ Cummins and capacity125 KVA.
19Supply and fix in repairs, Fan belt suitable for DG set Engine of make Kirloskar/ Cummins and capacity125 KVA.
20Supply and fix in repairs, Automatic voltage regulator suitable for DG set Engine of make Kirloskar/ Cummins and capacity125 KVA.
21Supply and fix in repairs, lubricant oil cooler suitable for DG set Engine of make Kirloskar/ Cummins and capacity125 KVA.
22Supply and fix in repairs,Engine Safety unitsuitable for DG set Engine of make Kirloskar/ Cummins and capacity125 KVA.
23Supply and fix in repairs, Thermostate suitable for DG set Engine of make Kirloskar/ Cummins and capacity125 KVA.
24Supply and fix in repairs,water pump suitable for DG set Engine of make Kirloskar/ Cummins and capacity125 KVA.
25M&L for replacement of battery terminal leads of 2AWG (35SQMM) copper wire single core PVC insulated 1.2 mitre long of colour coding red or black complete withbrass terminals fixed at site with petroleum jelly all as directed by engineer in charge.
26Removing existing unserviceble battery and supplied and fixed lead acid battery maintenance free 12 volts 180AH as per cat part No FXPO-MHD1800 of make EXIDE Xpress fully charged complete all as directed. Note : Contractor shall submit 3 yrs manufacturer waranty certificate includingpurchase voucher on completion of work.
27Dismantling of existing alternator of 62.5 KVA DG set Make Kirloskar/Cummins from foundation and disconnecting electrically and mechanically from the engine and taking out the alternator from siteto workshop Dimapurby Transportingafterrewinding of all the defective coils by using appropriate super quality copper winding wire of suitable gauge including varnishing and insulation paper complete all reassembling with engine at site andall as specified and directed by Engr in Charge.
28Preparation of Old Painted Surfaces of62.5 KVA DG SET and applying with Two Coat of Grey Synthetic Enamel Paint on Engine and Alternator Body and Two Coat of Red Synthetic Enamel Paint on Fan Guard and Two Coat of Black Synethic Enamel Paint on Base Channel Frame of the DG SET painted with Spray Painting Machine, complete all as specified and as directed.
29M&L for earthing complete withcopper earth plate electrode 60cm x 60cm x 3.15 mm buried directly in ground vertically to a depth not less than 2.25 mtr below ground level with the top edge not less than 1.5 mtr below ground level connected to copperstrip 20 X 3mm as earth lead by means of bolts, nuts, check nuts and washers of steel and other end connected to earthing test point including funnel, watering pipe of 40 mm bore, light grade GI pipe, wire mesh, charcoal or coke and common salt in alternate layers all around the earth electrode compacted thickness 15 cm, earthing pit in PCC (1:3:6) type C1, 50 mm thick pre-cast RCC cover slab (1:2:4) type B1 set in CM (1:4), reinforced with 8 mm dia TMT bars @ 10 cm c/c and suitable handle of 10 mm dia MS round bars including earth work in excavation in soft/loose soil, disposal of soil not exc. 50 meter complete and testing on completion all as shown in electrical plate No-3 of MES schedule, part-I including taking out old one complete all as specified and as directed. NOTES 1). The unit rate includecopper strip from top of earth plate upto 7.5 meter above ground level.
30Taking down unserviceableSolar street Light f 43/60 W LED dismantling, checking replacement of unserviceable parts and components as required and make thesolar light fittings operational to give rated illumination incl cleaning the solar plateand refixing the same after repair/replacement of spare components complete with repair of battery box as per requiredwelding workandall as specified and as directed by Engr in charge .Note :-(Spare parts/components shall be measured and paid separately under respective item of such "A").
31Supply onlySolar street Light fitting LED 40 Watts completeall as specified and directed by Engr-in-Charge.
32Supply onlySolarPanelmaterial Polycrystalline typenumber of cells 36, Solar Power 150Watt, Output Voltage 12V completeall as specified and directed by Engr-in-Charge. Note : Contractor shall submit minimum 10yrs manufacturer waranty certificate includingpurchase voucher on completion of work.
33Supply onlylead acid solarbattery maintenance free 12 volts 150AH Tubular as per cat part No 6LMS150L of make EXIDE Xpress fully charged complete all as directed. Note : Contractor shall submit 3 yrs manufacturer waranty certificate includingpurchase voucher on completion of work.
34S&F in repairs, Automatic Change over switch0f 4 pole3 Phase 415 V of capacity 200 Amp Make : Havells/ Indoasian/L&Tor equivalent.
35S&F in repairs, MCCB with Thermal - magnetic release of 200 Amps, 4 Pole, 415V, 36 kA, Ics=100%Icuwith adjustable over load settingand adjustable short circuit setting including all accessories complete all as specified and as directed. (Make: Legrand Cat Part No. 4202 48 or equivalent inSchneider/ L&T)
36S&F in repairs, MCCB with Thermal - magnetic release of 160 Amps, 4 Pole, 415V, 36 kA, Ics=100%Icuwith adjustable over load settingand adjustable short circuit setting including all accessories complete all as specified and as directed. (Make: Legrand Cat Part No. 4200 97 or equivalent inSchneider/ L&T)
37M&L for preparation of old painted steel pole of solar lightapprox 6 metre long and painting with two coats of aluminium paint over a coat of red oxide zinc chrome primer from top to bottom including battery bank and solar LED light bracket complete all as specified and directed
38M & L for XLPE insulated, PVC sheathed, armoured, heavy duty electric under ground cable, with stranded aluminium conductor, 1100 Volts grade of size 16 sqmm 2 core laid in trenches /floor or fixed on wall /pole in including brass compression cable glands, terminal lugs etc, including taking out old cable of any description complete all as specified and as directed.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail