|
| 1 | Cleaning the existing black topped surface including removal of bining materials with wire brushes and small picks, sweeping with booms or soft brushes and finally dusting with old gunny bags and or compressed air to receive bituminous materials etc. |
| 2 | OR-20-69 |
| 3 | OR-20-82 |
| 4 | OR-20-148 |
| 5 | Providing 75mm thick compacted WBM surface uniformly to the specified thickness to proper camber and consolidation with PRR incuding hire and runing charges of PPR and materials as per Technical Specification Clause 405 of MORD by manual means & as per direction of Engineer-in-Charge. |
| 6 | OR-20-69 |
| 7 | OR-20-82 |
| 8 | OR-20-148 |
| 9 | Providing and laying surface dressing using crushed stone aggreates of 13mm nominal size stone chipping and 60/70 penetration grade of bitumen as per cluse 510 of MoSRT&H specification for Road and Bridge works |
| 10 | OR-20-69 |
| 11 | OR-20-82 |
| 12 | OR-20-148 |
| 13 | Providing and laying Semi Dense Bituminous Concrete with Batch type hot mix plant using crushed agrgregate of specified grading premixed with bituminous binder of 60/70 penetration grade of bitumen, transporting the hot mix to work site , laying with a hydrostatic paver finisher with sensor control to the required grade level and alignment, rolling with smooth wheeled vibratory and tandom roller to achive the desired compaction as per Clause 508 of MoSRT&H specification for Road and Bridge works etc completed |
| 14 | OR-20-69 |
| 15 | OR-20-82 |
| 16 | OR-20-148 |
| 17 | Providing and applying tack coat with bitumen emulsion RS-1 using emulsion distributor at the rate of 0.25 of 0.30 kg per sqm on the prepared granular surfaces treated with primer and cleaned with Hydraulic broom as per Technical Specificition Clause 503 of MORD and as per Direction of EIC. |
| 18 | OR-20-69 |
| 19 | OR-20-82 |
| 20 | OR-20-148 |
| 21 | Clearing grass and removal of rubbish up to adistance of 50 metres outside the periphery of the area . |
| 22 | OR-20-69 |
| 23 | OR-20-82 |
| 24 | OR-20-148 |
| 25 | Reinfored cement concrete M-15 grade kilometer stone of standard design fixing in position including painting and etc. |
| 26 | OR-20-69 |
| 27 | OR-20-82 |
| 28 | OR-20-148 |
| 29 | Providing and fixing of retro-reflectorised, Place Identification sign as per IRC-67 made of high intensity grade sheeting vide clause 801.3, fixed over aluminum sheeting, 1.5mm thick or A.C.P. (Aluminum composite panel) used for sign boards with a thermoplastic core of low density polythylene (LDPE) between two thick sheets of aluminum with over all thickness of 3 mm and aluminum thickness of 0.3mm on both sides supported on mild steel angle post 75m x 75mm x 6mm firmly fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 45cm x 45cm x 75cm, 60 cm belowground level as per approved drawing including cost, convayance, royalty, taxes of all materials, labour, T&P, excavation, curing etc. complete, under supervision of E.I.C. |
| 30 | OR-20-69 |
| 31 | OR-20-82 |
| 32 | OR-20-148 |
| 33 | Providing and fixing of retro-reflectorised, cautionary, mandatory and informatory sign as per IRC-67 made of high intensity grade sheeting vide clause 801.3, fixed over aluminum sheeting, 1.5mm thick or A.C.P. (Aluminum composite panel) used for sign boards with a thermoplastic core of low density polythylene (LDPE) between two thick sheets of aluminum with over all thickness of 3 mm and aluminum thickness of 0.3mm on both sides supported on mild steel angle post 75m x 75mm x 6mm firmly fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 45cm x 45cm x 75cm, 60 cm belowground level as per approved drawing including cost, convayance, royalty, taxes of all materials, labour, T&P, excavation, curing etc. complete, under supervision of E.I.C. |
| 34 | OR-20-69 |
| 35 | OR-20-82 |
| 36 | OR-20-148 |
| 37 | Providing and Fixing Reinforced cement concrete M15grade 200 Mtr. stoneof standard designfixing in position including painting and printing, etcas per direction of the Engineer in charge |
| 38 | OR-20-69 |
| 39 | OR-20-82 |
| 40 | OR-20-148 |
| 41 | Providing and erecting Main Information Board One Side retro-reflectorised sign as per IRC-67 made of high intensity grade sheeting vide clause 801.3, fixed over aluminum sheeting, 2.00mm thick or A.C.P. (Aluminum composite panel) used for sign boards with a thermoplastic core of low density polythylene (LDPE) between two thick sheets of aluminum with over all thickness of 4mm and aluminum thickness of 0.5mm on both sides supported on mild steel angle post 75m x 75mm x 6mm, 2 nos firmly fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 45cm x 45cm x 75cm, 60 cm belowground level as per approved drawing including cost, convayance, royalty, taxes of all materials, labour, T&P, excavation, curing etc. complete, under supervision of E.I.C. |
| 42 | OR-20-69 |
| 43 | OR-20-82 |
| 44 | OR-20-148 |
| 45 | Providing and erecting ASSET Board One Side retro-reflectorised sign as per IRC-67-2012 made of high intensity grade sheeting vide clause 801.3, fixed over aluminum sheeting, 2.00mm thick or A.C.P. (Aluminum composite panel) used for sign boards with a thermoplastic core of low density polythylene (LDPE) between two thick sheets of aluminum with over all thickness of 4mm and aluminum thickness of 0.5mm on both sides supported on mild steel angle post 75m x 75mm x 6mm, 2 nos firmly fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 45cm x 45cm x 75cm, 60 cm belowground level as per approved drawing including cost, convayance, royalty, taxes of all materials, labour, T&P, excavation, curing etc. complete, under supervision of E.I.C.(1800x1200 mm) |
| 46 | OR-20-69 |
| 47 | OR-20-82 |
| 48 | OR-20-148 |
| 49 | Providing fitting and fixing of Guard Stone of Circular Size of 250mm Dia & 1950 mm height including painting with all cost of materials wages of labour etc. complete as per the direction of the Engineer-in-Charge. |
| 50 | OR-20-69 |
| 51 | OR-20-82 |
| 52 | OR-20-148 |
| 53 | White wasing two coats on parapet walls and tree trunks inlcuding preparation of Surface by cleaning scraping etc. |
| 54 | (OR-20-69) |
| 55 | OR-20-82 |
| 56 | OR-20-148 |
| 57 | Earth workin hard soil or gravelly soil within 50m. Initial lead and 1.5m initial lift including rough dressing and breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3m in depth with cost of labour, CESS, T&P etc. complete as per specification and direction of the Engineer-in-charge. |
| 58 | OR-20-82 |
| 59 | Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorising glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35 .The finished surface to be level, uniform and free from streaks and holes. |
| 60 | OR-20-69 |
| 61 | OR-20-82 |