Supply, Installation, Testing And Commissioning Of Various Balance Electrical And Mechanical Works For Water Supply Scheme Adina Draripora, Budgam- 1 Supply, Installation, Testing & Commissioning Of Open Well ( Clear Water ) Submersible Pumping Equipmentas Per Following Details Confirming To Is 14220 : 1994 With All Latest Amendments Pump :-• Discharge: 3500 Gph• Head : 35 Meters• Speed: 2900 Rpm• Type Of Pump: Submersible Open Well• Quality Of Water To Be Handled :Clear Water? Name Of The Manufacture Or Trade Mark.? Serial No Of The Pump Set.? Pump Type.? No. Of Stages.? Total Head & Discharge.Motor:-•Type: Squirrel Cage 3 Phase Induction Motor• Motor Rating : Suitable For Above Parameters • Method Of Starting:Star – Delta.• Frequency:50Hz + 3%• Speed:2900 • Voltage :415 + 05 % • Class Of Insulation:Suitable For Above Rating.• Liquiddensity :Max 1000 Kg / M³the Motor Shall Be Made Of Corrosion Resisting Materials To Resist Corrosion Under Normal Conditions And The Motor Shall Have A Name Plate Giving All Required Information. The Job Includes P / F Of G.I. Nipples As Per Pump Diahaving One Side Threaded And The Other Side Fitted With 18 Mm Thick M.S. Flange Suitable For 80 Mm Dia Column Pipe By Way Of Welding In Double Layers. The Flange So Fitted Shall Have Suitable Dia Of Holes For Accommodating Bolts Etc.Note :- The Equipmentshall Be Supported With Test Certificate From Oem ( Original Equipment Manufacturer ) Confirming To The Relevant Is Code. 2 Non-Return Valve: Providing, Fitting, Testing And Commissioning Of Non Return Valve As Per Following Specifications :• Nominal Dia : 80 Mm• Rating : Pn 1.6• Body : Ductile Iron • Corrosion Protection – Epoxy Coatingeachvalve Shall Be Provided With 02 No Matching Flanges 3 Fabrication / Erection Of Channel Iron Column To Act As Support For Resting Of Monorail Crane As Per Following Details:-The Job Also Includes Painting Of Complete Structure In One Coat Of Red Oxide And 02 Coats Of Enamel Metal Paint.Vertical Posts = Ismc 150No. Of Vertical Posts = 02 Nos.Vertical Channel Section Each Post = 02 Nos ( Seam Welded Face To Face ) .Vertical Post Bracing = Ismc 100Sole / Matching Plates = 500X300x12 Thickheight Of Vertical Posts = 4.5 Msize Of Vertical Post Concrete Blocks = 600X600x900 Mm ( Depth ) Concrete Grade = M20welding Electrode = Overcord Ss Of Adore / Esab / L&T / Advanimonorail Section = Ismb 200Length Of Monorail = 5Msteel Detail :I. Ismc 150 4.5Mx2x2 = 18 M @ 16.4Kg / M = 295 Kgii Ismc 100 0.25Mx8x2x2 = 8 M@ 9.2Kg / M = 73.60 Kgiii Plate 0.500X0.300X8 ( 12Mmthk ) = 1.20 M² ( 12Thk ) = 112.80 Kgiv Monorail Ismb200 5 M @ 25.4 Kg / M = 127Kgsv Bolts / Nuts ( L.S ) = 20Kgs Total = 628.40 Kg 4 Supply, Installation , Testingand Commissioning Of 02 Ton Capacity, Manually Operated Chain Pulley Block. The Chain Pulley Block Shall Have 6 M Lift. It Shall Also Include Suspension Arrangement Made Of 10 Mm Thick Steel Wire Rope Or Gi Wire Capable Of Supporting Rated Load And 2 No. D-Shackles ( With Nut Locking System ) For Fitment Of Chain With Suitable Size. 5 Supply, Installation, Testing & Commissioning Of Aluminium Conductor Power Cable Having The Following Technical Specifications: -35Mm2, 3.5 Core, Suitable For Lv 1.1Kv / 650V Grade, Xlpe Insulated, Pvc Inner Sheathed, Armoured Confirming To Is7098- Part 1, 1988. The Job Also Includes Providing & Fixing Of 35Mm2aluminium Thimbles Duly Crimped With The Cable Termination Ends By Crimping Tool For Making All Connection. 6 Providing, Installation, Testing & Commissioning 25Kva Voltage Controller As Per Technical Specifications Here Under: • Type Of Voltage : Manually Operated Copper Wound Controller3phase, Ac Power Capacity : 25 Kva• Type Of Regulator : Single Plate With Electrolytic Copper Contacts• Input Voltage : 150 Volts.• Output Voltage : 415 ± 05% Volts.• Frequency :50± 3 C / S.• Windings : Electrolytic Grade Copper Of Adequatesection, • Vacuum Impregnated & Suitable Dried / Oven Dried• Insulation : Fibre Glass Insulations To Tested Parameters.• Efficiency :98 %• Cooling : Oil Cooled • Temp. Rise ( Max ) : 30°C Above Ambient • Mounting : On Uni-Directional Wheels.• Correction Rate : 30 Volts Per Step • Wave Form Distortion : Virtually Nil • Duty Cycle : 100% Continuous.• Enclosure : Pressed Cgr Ms Sheetthe Enclosure Shall Be Given Anticorrosive Painting Inside And Powder Coating / Enamel Painting Outside The Body.• Core Laminates : High Grade, Low Eddy Loss, Grain Oriented Silicon Steel Laminations.• Load : 3 Phase Induction Motor Load.The Name Of The Wss, Name Of Supplier, And Date Of Its Supply Shall Be Written On The Outer Body Of The Equipment In White Paint. Enclosure / Body Shall Have Drain Plug At An Appropriate Place & With Unidirectional Wheels At Four Corners.The Equipmentshall Be Supported With Test Certificate From Oem ( Original Equipment Manufacturer ) 7 Providing, Installation , Testing And Commissioning Of 60W, Led ( Street Light Type ) Input: 90-240 V, 50 Hzpower Factor: >0.9Color Temperature: 4K - 6.5Kbeam Angle: 120° - 170°Lumens: >12000Operating Temperature: -20°C To 60°Cthe Led Shall Have Pressure Die Cast Aluminum Housing With Power Coated Finish And Having Ingress Protection Upto Ip-68.The Led Shall Be Properly Fitted On The Arm Ofwall And Connected Bysuitable Wiring. 8 Providing Of Tool Kit Of Reputed Make Consisting Of Following Items A ) Spanner Set=12 Pieces Of Different Size ( Complete Set ) B ) Ring Set =12 Pieces Of Different Size. ( Complete Set ) C ) Nose Pliers =2 Nosd ) Cutting Pliers=2 Nose ) Screw Driver=2Nosf ) Hammer ( 1.5Kg ) =1Nog ) Pipe Wrench ( 450Mm ) =1Noh ) Multimeter=1Nothe Job Includes Providing Of Led Rechargeable Lantern ( 01 No ) Of Reputed Make. 9 Electrification Of Pump House:-Providing And Fitting Of Lighting / Fan Points For Ac / Dc Fitting In 1.5 Mm Sq. Multi Strand Pvc Wire As Conductor To Be Laid / Carried In Pvc Channel / Conduit As Per Site Requirement. The Job Includes Providing And Fitting Of 5 Amp. Switch Button / Angle Holders To Be Fitted With 9 Watt Led Lamps Of Reputed Make Inside The Pump House. 10 Providing And Fitting Of Heating Points In 2.5 Sq.Mm Multi Stranded Conductor To Be Laid Carried In Pvc Channel / Conduit As Per Site Requirement. The Job Includes Providing And Fitting Of 16 Amp. Switch Socket Combine. 11 Providing And Fitting Of Distribution Board Sp&N ( Regal Grey ) With 1 No. Of Incoming And Outgoing 16 Way, Fitted With Mini Mcb “C” Series 6 Amp ( 8 No ) . For Lighting Of Pump House, 10 Amp ( 4 No. ) For Flood Lights And 16 Amp ( 3 No’S. ) For Heating Pointsand 36 Amp. Mcb ( Mains ) The Job Includes The Cost Of 4Mm Sq. Multi Stranded Conductor To Be Laid As Service Line For Lighting System. 12 Supply, Installation, Testing & Commissioning Of 1000Vapure Sine Wave Power Inverter Along With 12V, 150Ahautomotive Battery Including Providing / Laying Of 1.5 Sq Mm Wire For Lighting / Charging Points As Per The Requirementatwss. 13 Providing / Laying Of 3Mm Thick High Density Anti Skid Rubber Floor Matting On The Machine Floor Level Area Including The Floor Surface Area Around Power Control Panels And Other Gadgets. The Job Includes Cleaning Of The Floor, Removing Of Dust, Dirt, Grease And Loose Sand Grains If Any. Applying The Adhesive Of Sufficiently High Bonding Strength Both On The Floor As Well As On The Under Surface Of The Rubber Matting For Fixing. 14 Fabrication, Welding And Providing At Site M S Angle Iron For Fabrication Of Beds Out Of ( Isa-50X50x5 Mm ) . The Top Of The Bed Shall Be Fixed With 19Mm Thick Ply Board Of Required Size. The Bed Size Should Be 4X6’ With 06 Legs / Vertical Supports Each Of 2Ft Height.The Job Also Includes Providing At Site Of 02 No Of Quilts Of Size 5’X8’ ( 06 Kg Each ) , 02 Nos. Mattresses Of Size 6’X4’ ( 05 Kg Each ) , Along With Covers, 02 Nos. Pillows With Covers, Bed Sheets, 02 Nos. Of Double Bed Blankets Of Good Quality. The Job Also Includes Providing Of Pressure Cooker 5Ltr ( 01 No. ) , Steelpatila 5 Ltrs ( 02 No’S ) , Cooking Heater 01 No., Room Heater ( Metal Enclosure ) 01 No., Steel Buckets 01 No., Plastic Bucket With Mug 01 No, Steel Glasses 06 No’S., Steel Plates With Largespoons And Bowls 03 No. Each, 5Kg Gas Cylinder With Burner / Stove. The Job Also Includes Providing Of Thermo Cool 13’X10’ Along With Excel Matting Of 13’X10’ Size Purchased In The Presence Of Person Incharge As Per His Choice. 15 Supply, Installation, Testing & Commissioning Of Submersible Copper Conductor Power Cable 10 Sqmm, 3.0 Core, Suitable For 415+10%V Of Conforming To Is 694:1990.The Job Is Inclusive Of Providing & Fixing Of 100 A Copper Thimbles Duly Crimped With The Cable Termination Ends By Crimping Tool For Making Connections. 16 S / I / T / C Of63 Kva ( 11 / 0.440Kv ) , 3 Phase, Neutralhv Power Distribution Transformer Of Level-2 Type As Per Is 1180 ( Part 1 ) Of 2014 With Following Specifications:-Capacity = 63 Kva, 3-Phase And Neutral.Operating Conditions.Input= 11000 Voltsoutput= 440 Volts Ac Supply In 3- Phase.Terminals:-Input=3 No. Ht Bush Rods With Insulators, Washer Nuts Etc.Output = 4 No. Lt Bush Rods Switch Insulators Washer, Nuts Etc. Core = High Permeability Core For Heat Dissipation Fabricated Out Of Suitable Size And Gauge Strips.Transformer Coils = Suitable Number Of Ht And Lt Coils In Each. The Transformer Coils Shall Be Fabricated Out Of Superior Quality Aluminum Wire / Strips Properly Wound So As To Make It Flux Leak-Proof. The Ht Transformer Should Be Completely Filled With Suitable Grade Transformer Oil Up To Required Level. The Job Includes Carriage And All Leads And Lifts Involved. The Ht Transformer Shallbeofreputed Makefroman Iso Certifiedcompany As Per Relevant Standards And A Test Certificate Shall Be Provided Before Installation. The Transformer Shall Also Beprovidedwithbreatherfillwith Silica Gel Crystals, Conservator With Oil Level Indicator, Explosionvetand Adequate Radiator Fins / Tubes. The Impedance Of Transformer Shall Be As Per Is: 1180 ( Part 1 ) 2014 With Latest Amendments.Note: The Scope Of The Work Shall Include Obtaining Of Necessary Inspection / Clearance Certificate From The Concerned Department For All The Required Equipment. The Testing And Commissioning Shall Be Completed Only After Obtaining Above Certificate.Enclosure = The Core, Coils & Bracket Shall Be Enclosed In Ms Tank Of Suitable Thickness With Cooling Conducts / Fins Or Either Side. The Ms Tank Shall Be Painted In Two Coats Of Enamel Synthetic Paint And The Tank Shall Be Fitted With Drain Cock / Plug And Graduated Glass Tube Oil Level Indicator.The Job Includes Providing Fitting Of S / L Clamps ( 100-150 ) For All Terminal Lt / Ht Connections Of Above Transformer.Note:-The Firm Has To Get / Provide Noc / Inspection Clearance Certificate From Concerned Departments For Making Electrical Connections.The Power Transformer Shall Be Supplied With Manufacturers Test Reports / Certificates. The Manufacturer Should Be Preferably Cpri Certified. 17 Supply, Installation, Erection Of Ms Tubular Poles-Sp33 Isi Mark Htl-Is 1161 Or Is 2713Of 9M Long Having Reduced Area Of 4X5x6 From Top To Bottom And Shall Be Anti-Corrosive Painted. The Job Includes Providing / Laying Of Cement Concrete Block In 1:2:4 Mix ( Of Size 3Ft Deep X1ft Above The Ground ) For Grouting Of Each Pole. The Pole Shall Be Welded With 40Mm X 40Mm Square M S Plate, 5 Mm Thick At Bottom Of The Pole And Having Duly Drilled Holes At Top / Appropriate Position For Accommodating Ms Fasteners For Holding Safety Devices.The Job Includes The Cost Of Applying Black Paint To Poles Up To A Height To 1.50M And Rest Of The Portion With A Silver Paint Shade In 2 Coats. The Job Includes Gi Strip Earthing As Per Iee Rules.The Job Also Includes Providing And Fitting Of Pin / Discinsulators , Cross Arms, Nuts And Bolts As Per The Requirements Complete In All Respects To Be Made Ready For Laying Of Acsr Conductor On Two Pole Structure. 18 Providing And Fitting Of Acsr 0.05 Aluminum Conductor 19 P / F Of Do Fuse Set Suitable For 11 Kv Line 20 P / F Of Lightening Arrestor Set For 11 Kv Line 21 Providing, Fitting, Testing And Commissioning Of 250 Ampere, 4Pole, 50 Ka Mccb ( With Enclosure ) To Be Installed On The Lt Distribution System Of The Transformer. The Job Includes The Cost Of Minor Wiring / Thimbles Required For Connecting The Same On The Input Circuit Of The Lift Station. 22 Providing Fitting Of 11Kv Go Set Polymer Insulator Type Complete In Every Respect With All Allied Accessories For Sub Station. 23 P / F Of Guy Wire With Insulator, Anchoring Rod And Turn Buckle. 24 P / F Of 8’ Long Ismc 100 Channels For Transformer Bed Complete With Nuts And Bolts 25 P / F Of 8’ Long Ismc 75 Channels Complete With Nuts And Bolts For Fitment Of Link Set, D / O Set & Lightening Arrestor Set Etc. 26 Fabrication / Providing / Fitting Of Y Junctionwith Wash Out Arrangement Fabricated Out Of ( Class – B ) M.Spipe Of 80 Mm Size ( 12 Mtrs ) And Welded With 18 Mm Thickms Flanges As Per Table – 5 In Two Runs Of Welding . The Job Also Includes Cost On Account Of Suitable Size Nuts And Bolts , Rubber Packing In The Flanged Joints.