Repair / Maintenance Of Summer Appliances And Certain Misc Air Conditioning Works In Tech Area At Af Stn Gwalior, gwalior-Madhya Pradesh

Military Engineer Services-MES has published Repair / Maintenance Of Summer Appliances And Certain Misc Air Conditioning Works In Tech Area At Af Stn Gwalior. Submission Date for this Tender is 18-06-2022. Air Conditioner Tenders in gwalior Madhya Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

32539960
Repair / Maintenance Of Summer Appliances And Certain Misc Air Conditioning Works In Tech Area At Af Stn Gwalior
Open Tender
Indian
Madhya Pradesh
gwalior
18-06-2022

Tender Details

Repair / Maintenance Of Summer Appliances And Certain Misc Air Conditioning Works In Tech Area At Af Stn Gwalior

Key Value

Document Fees
INR 500 /-
EMD
INR 60600.0 /-
Tender Value
INR 30.30 Lakhs /-

BOQ Items

Name of Work : REPAIR / MAINT OF SUMMER APPLIANCS AND CERTAIN MISC AIRCONDITIONING WORKS IN TECH AREA ATAF STN GWALIOR
Sl. No. Item Description
1Disconnecting, dismantling and taking out the defective/ non functional desert cooler of any description and in any position and any floor installed at direct approch (where any ladders and other T&P are not required to remove the desert cooler from position) strip opening of desert cooler, cleaning, servicing, oiling & greasing etc of desert cooler taking out and removing unserviceable/defective parts and internal wiring, replacement of unserviceable & damaged parts and internal wiring, reassembling & testing of the desert cooler complete all as specified and directed Note :- (i) The replacement of defective/ non-fuctional parts shall be measured & paid separatly as ` supply only" under respective item of schedule A/BOQ and fixing charges for new items are deemed to be included under this item and replacement of unserviceable/damaged body portion i.e panel/switch board/Pump/Motor/bottom/top/grills/frame etc of the desert cooler shall also be measured and paid for separatly under appropriate item of schedule `A"/BOQ . (ii) The rate for above items are deemed to include for replacement of necessary unserviceable screws/nuts, bolts/washer/packing etc with new one.
2Supply only following parts for existing desert cooler of any description, any capacity, any make and in any position complete all as specified and directed. Note :- (i) Make of the parts must be same as per existing desert cooler (ii) The cost of fixing and testing of spare parts is deemed to be included under schedule A item No 1.00 here-in-before
3(a) 15 mm dia PVC flexible water pipe
4(b) PVC distributor 3 way for 15 mm dia water distribution
5(c )1.5 sqmm 3 core PVC insulated copper cable round type suitable for 1100 volts grade.
6(d)Submercible pump PVC body for desertcooler single phase, 230 volt AC flow rate 1100 LPH, Max head 1850 mm Make:- Balaji or equivalent as approved
7(e) PVC switch board with and incl piano type switch 5 Amps-02 Nos one way and 1 No selctor switch 4 way 15 Amp 230 volts for speed control and one red indicator incl wiring complete as directed
8(f) Air curtain panels (side and back removale panels) of any description and size for different size of desert coolers made to shape and size with using 20 SWG guage PGI sheets as per requirement incl necessary moulding etc to suit the existing desert cooler openings
9(g) aluminium fan blade (set of three blades) for desert cooler motor of any description to match existing motor
10(h) Wood wool pads of required size as apporved (three in each) for desert cooler)
11(j)Desert cooler fan motor of existing make/model/ capacity/sweep, 900/1200 RPM including making connection complete all as specified and directed
12(k)Desert cooler fan motor of existing make/model/ capacity/sweep, 1200/1400 RPM (Exature fan kit) including making connection complete all as specified and directed
13(l) Chicken wire mess having hexagonal wire mesh15mm size mesh and 0.5mm dia of wire for supporting to the wood wool pads.
14(m) Front grills of existing shape and size and made out of 20 SWG PGI sheet.
15(n)15mm bore ball brass valves high pressure with polythene float and fly nut complete
16(o) 15mm bore Gun metal gate valve with iron wheel head, screwed both end for iron pipe Make NMC/BIR/Leader
17(p ) PVC connection pipe 15mm size 450 mm length complete with PTMT nuts on both ends.
18Disconnecting,dismantling and taking out the non functional Water Coolers of any description, checking, replacement of unserviceable parts including testing complete all as specified and directed. Note :- Replacement of new parts shall be measured and paid separately under relevant item of Sch "A"/BOQ as Supply only.
19Supply only of the following parts for existing water cooler of any description, any capacity, any make and in any position complete all as specified and directed. Note :- (i) Make of the parts must be same as per existing water cooler (ii) The cost of fixing and testing of spare parts is deemed to be included under schedule A/BOQ Item No 3.00 here-in-before
20(a) Base tray stainless steel for 40/80 and 60/120 ltrs capacity
21(b) Base tray stainlesssteel for 150/150 ltrs capacity
22(c) Side cover stainless steel for 40/80 ltrs capacity
23(d) Side cover stainless steel for 60/120 ltrs capacity
24(e) Side cover stainless steel for 150/150 ltrs capacity
25(f) Water storage tank with chiller made of stainless steel incl copper tube for 40/80 Ltrs capacity
26(g) Water storage tank with chiller made of stainless steel incl copper tube for 60/120 Ltrs capacity
27(h) Water storage tank with chiller made of stainless steel incl copper tube for 150/150 Ltrs capacity
28(j) Water tank chiller"s top cover made of stainless steel for 40/80 ltrs capacity
29(k) Air cooled condenser with ventury, copper 3 row for 40/80 ltrs capacity
30(l) Air cooled condenser with ventury, copper 3 row for 60/120 ltrs capacity
31(m) Air cooled condenser with ventury, copper 4 row for 150/150 ltrs capacity
32(n)Relay unit currrent type Make : Kilxen, Model 5441/Electrica or other make as approved
33(o) Relay pin type (Potential type) Make Tecumshah Model No 1062/KCL 85001, 02, 03, 04 or other equivalent make as approved
34(p) Thermostat 220 volts Make Indfoss/Renutrol /Rockwell
35(q) Over load protector suitable for 40/80 Ltr.60/120 Ltr water cooler
36(r) AC electric condenser motor 25 watt, 230 volts, 1250/1400RPM, single speed
37(s) AC electric condenser motor 30 to 35 watt, 230 volts, 900 /1400 RPM, single speed
38(t) AC electric condenser motor 75 to 90 watt 230 volts 1400 RPM single speed
39(u) Brass nipple 15 mm dia for inlet and out let connection of water cooler any type/size incl PVC connection 15 mm dia with brass coupling on both ends
40(v) Drain pipe PVC flexible ¼" dia .
41(w) end circle clip for Drainpipe 1/4" dia
42(x) Wiring kit of flexible PVC insulated copper condutor cable of existing size
43(y) CP brass push cock 15mm dia (ISI marked) inner/outer threadedas directed
44(z)Harmetic sealed unit compresssor of capcity40/80 Ltrs Model No. KCE443 of water cooler incl vaccum testing and filling of refrigerant gas to required pressure
45(ab)Harmetic sealed unit compresssor of capcity60/120 Ltrs Model No. KCE461of water cooler incl vaccum testing and filling of refrigerant gas to required pressure
46(ac)Harmetic sealed unit compresssor of capcity150/150 Ltrs Model NO.AHR13/513 of water cooler incl vaccum testing and filling of refrigerant gas to required pressure Make Emerson copland/ carrier/ Blue star/Tecumsah Note : item No 4.25 to 4.27: The cost of fixing brazing to suction and discharge line and testing of compressor at site is deemed to be included under schedule A item (ii) The rate quoted against items is demeed to be inclusive of labour for filling of refrigerant gas, However the refrigerent gas shall be measured and paid under respective item.
47(ad) Fan blade suitable for 40/80 ltrs capacity
48(ae) Fan blade suitale for 60/120 ltrs capacity
49(af) Fan blade suitable for 150/150 ltr capacity
50Disconnecting,dismantling and taking out the non functional Refrigerator of capacity 165 to 360 ltrs of any description, checking,replacement of unserviceable parts including testing complete all as specified and directed. Note :- Replacement of new parts shall be measured and paid separately under relevant item of Sch "A"/BOQas Supply only.
51Supply only of the following new parts for existing refrigerator of any description, any capacity of 165 to 360 ltrs & any make and in any positioncomplete all as specified and directed. Note :- (i) Make of the parts must be same as per existing refrigerator (ii) The cost of fixing and testing of spare parts is deemed to be included under schedule A /BOQ item No 5.00 here-in-before
52(a) Main door gasket magnetic type
53(b) Thermostat switch with knob 230 volt suitable for single door refrigerator
54(c) Thermostate switch with knob 230 volts suitable for double door refrigerator of capacity 165 to 360 ltrs
55(d) Relay box type 220 volts 3 pin/4 pin Make KCL/Rentrol/Indofos/Annapurna
56(e) Freezer door with spring & clamp
57(f) Pin type/screw type bulb Make Philip/bajaj/Crompton
58(g) Condensor water drain off tray of pvc same as per existing model complete
59(h) Door switch 230 volts
60(j) Chiller tray plastic.
61(k) Refrigerator freezer coil & freezer coil type/roll bound type for 165 ltr to 230 ltrs capacity
62(l) Refrigerator freezer coil & freezer coil type/roll bound type for 250 ltrs to 310 ltrs
63(m) Bulb holder assembly complete
64(n) InnerPUF Insulationfor 165 to 250 ltr capacity
65(o) Innter PUF Insulationfor 275 to 310 ltr capacity
66(p) PVC inner cabinet moulded in shape suitable for capacity 165 to 230 ltrs
67(q) PVC door cabinet (factory made) moulded in shape suitable for capcity 275 to 330 ltrs
68(r) Condesner coil for 165 to 230 ltrs capacity
69(s) Fan motor of frost free for double door refrigerator of capcity 300 to 360 ltrs
70(t) Bi-metalic thermostat of capacity -5 ºC cut in temperatur for 300 to 360 ltr capacity
71(u) Fuse for bi-metalic thermostat of 65 ºC /70ºC for 300 to 360 ltrs capacity
72(v) PCB for 165 to 265 ltrs capacity
73(w) PCB for 300 to 330 ltrs capacity
74(x) Timer for double door refrigerator make sumsung /WirlpoolGodraj/LG
75(y) Sealed unit compressor Model No. THK 1340 for 165 ltrs capacity incl vacuum testing and filling of refrigerant gas to required pressure
76(z) Sealed unit comrpressor Model No. THK 1352/51for 220 to 330 ltrs capacity incl vacuum testing and filling refrigerant gas to required pressure
77(aa) Vegetable tray of any capacity refrigerator Note : item6.24 to 6.25 (i) the cost of fixing brazing to suction and discharge line and testing of compressor at site is deemed to be included under schedule A/BOQ Item No 5.00 here-in-before (ii) The rate quoted against items is demeed to be inclusive of labour for filling of refrigerant gas, However the refrigerent gas shall be measured and paid under respective item.
78Supply and fixing in replacement rotational moulded polyenthylene Three layer water storage tanksof Capacity 5000 ltrs (cylinderial vertical with closed top) and 20mm bore size with float valve, hoisted and fixed in position including connection of water supply line and testing complete all as specified and directed.
79S & F plug top 3 pin 16 amp
80S & F plug top 3 pin 6 amp
81Disconnecting and taking out existing defective non functionaldehumidifier of capcity 600 CFM of make ` BRY air model FEB 1000 in any position, three phase, 50 HZ, strip opening, cleaning and servicing of dehumidifire including taking out and removing unserviceable/defective wiring & parts, painting the bottom with one coat of black synthetic enamelled paint, reassembling and testing of the dehumidifire complete all as specified and directed Note (i) The replacement of defective/nonfuctional parts shall be measured and paid sepratly as "supply only" under appropriate item of Sch A and fixing charges for new items are deemed to be included under this item. (ii) The rate for above items are deemed to include for transportation of dehumidifier to & from work shop as approved by Engr-in-charge for necessaryrepair and testing & replacement of necessary unserviceable screws/nuts/bolts/washer/packing etc with new one.
82Supply only of the following spare parts for BRY AIR make dehumidifier & Model NO EFB-1000 complete all as specified and directed Note- The Elements of fixing & testing of the item is deemed to be included in the rates quoted by the contractor for respective schedule A/BOQ item No 7.00here-in-before
83(a) Heater 3 KW
84(b) Micro switch MCL-15D
85(c ) Thermostate
86(d) Air pressure switch
87(e) Timer set 800-M
88Supply of Refrigerant gas (R-22) Monochloro Difluoro Methane (CHCLF2) (Make :- Mafron-22/Refron-22/Floron 22) duly filled in factory sealed cylinder complete all as specified and directed. Note :- The cost of cylinder not to be included in unit rate quoted.The empty cylinder shall be returned back after use of gas.
89Supply of Refrigerant gas (R-407C)(NonCFC) duly filled in factory sealed cylindercomplete all as specified and directed. Make :- Mafron/Floron Note :- The cost of cylinder not to be included in unit rate quoted.The empty cylinder shall be returned back after use of gas.
90Supply of Refrigerant gas (R-410)(NonCFC) duly filled in factory sealed cylindercomplete all as specified and directed. Make :- Mafron/Floron Note :- The cost of cylinder not to be included in unit rate quoted.The empty cylinder shall be returned back after use of gas.
91Supply of Refrigerant gas (R-32) Monochloro Difluoro Methane (CHCLF2) (Make :- Mafron-32/Refron-32/Floron 32) duly filled in factory sealed cylinder complete all as specified and directed. Note :- The cost of cylinder not to be included in unit rate quoted.The empty cylinder shall be returned back after use of gas.
92Supply of lubricating oil (Minral oil Capila D-68) antifreezing for refrigeration in factory sealed drumcomplete all as specified and directed. Make :- Bharat Petroleum/Indian Oil/Volvo line
93Supply of lubricating oil (POE-320) antifreezing for refrigeration in factory sealed drumcomplete all as specified and directed. Make :- Danffos/Emerson/Indian Oil/Volvo line
94Disconnecting & taking out the non -functional voltage corrector (stabilizer of any description and in any position & strip opening of voltage corrector (stabilizer) of following capacity single phase air cooled of any make, taking out unserviceable/defective wiring & parts, cleaning and servicing complete incl replacement of unserviceable parts with new one and unserviceable wiring with new PVC insulated and unseathed stranded copper conductor cable of existing size, reassembling, connecting and testing incl cleaning the exposed surfaces of stabilizer complete all as specified and directedNote :- Replacement of unserviceable parts shall be measured and paid separatly as supply only (a) 7.5 to 10 KVA
95(b) 4/5 KVA
96Supply only of following new parts suitable for 7.5 to 10 KVA, voltage stabilizer complete all as specified and directed Note - (i) Fixing and testing element of the these items is deemed to include under respective schedule `A"/BOQ item No 9.01 and 9.02 here-in-before (ii) Make, shape and size of part shall be the same as per existing or as directed
97(a) Power transformer input 140-280 volts & out put 220 volt ± 9% for 7.5 to 10 KVA
98(b) Power transformer input 140-280 volts & out put 220 volt ± 9% for 4/5 KVA
99(c) Relay 24 volts singal change over 60 Amps
100(d) Relay 24 volts singal change over 30 Amps
101(e) Auxillary transformer 12/24 volts
102(f) PCB 4 to 10 KVA suitable forexisting make of stabilizer
103(g) Volt meter 0-300 Volts 50mm square type
104(h) Switch SPDT 220 volt 1 Amp
105(j) Indicator lamp green/red 220 volts
106(k) Toggle switch 15 Amps 2 way 220 volts
107Taking down old unserviceable voltage stablizer of capacity 5KVA/4 KVA
108Supply and fixing voltage stablizer electronic typefor automatic operation single phase naturally air cooled, indoor, type, wall mounted for input variation between 170 V to 250 V with output voltage stablized at 230V with accuracy of + 2.5% and of capacity 5.0 KVAcomplete all as specified and directed
109Supply and fixing voltage stablizer electronic typefor automatic operation single phase naturally air cooled, indoor type, wall mounted for input variation between 170 V to 250 V with output voltage stablized at 230V with accuracy of + 2.5% and of capacity 4.0 KVA complete all as specified and directed
110M&L for MCB Plug and socket DBs with one MCB SP 25 /32 Amps, 10 KA, "C" Series complete all as specified and directed.
111Taking down old unserviceable PVC cable of any conductor and any core complete all as specified and directed
112S&F PVC insulated & sheathed copper round cable 1100 volts of size 4.0 sqmm 3 core incl copper thimble/pin type lugs connecting both side and testing complete all as specified and directed.
113All as per item No 16.00 here-in-before but of Size 4.0 sqmm 4 core
114All as per item No 16.00 here-in-before but of Size 4.0 sqmm 5 core
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail