Repair Maint Of Summer / Winter Appliances At New Cantt Allahabad, allahabad-Uttar Pradesh

Military Engineer Services-MES has published Repair Maint Of Summer / Winter Appliances At New Cantt Allahabad. Submission Date for this Tender is 01-07-2022. Mechanical engineering Service Tenders in allahabad Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

32538343
Corrigendum : Repair Maint Of Summer / Winter Appliances At New Cantt Allahabad
Open Tender
Indian
Uttar Pradesh
allahabad
01-07-2022

Tender Details

Repair Maint Of Summer / Winter Appliances At New Cantt Allahabad

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 24-Jun-2022 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 01-07-2022

Key Value

Document Fees
INR 500 /-
EMD
INR 90000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: REPAIR MAINT OF SUMMER/WINTER APPLIANCES AT NEW CANTT ALLAHABAD
Sl. No. Item Description
1AC WINDOW/SPLIT TYPE
2Repair/maint of window type AC/split AC any capacity of any make by cleaning and servicing of serviceable parts replacement of wiring kit, knobs & unserviceable parts replacement of air filter made of jute and reassembling the serviceable spare parts etc and testing for smooth functioning and re installation at site or deposit in MES store yard after repair. [Notes : (a) spare parts shall be measured and paid separately under respective items. (b) Replacement of nuts, bolts and washers deemed to be included in unit rate. (c) Minor repair of chesis by brazing/welding work deemed to be included in unit rate.]
3Removing burnt/defective sealed compressor unit of any make from any type of air conditioner window type 1.5 ton capacity by cutting of suction and discharge lines unscrewing the foundation nuts, bolts etc, supply amd fixing of new sealed compressor unit of suitable make as existing by connecting suction and discharge lines with gas welding/brazing work and tightening foundation nuts & bolts etc all as directed. Make:Emerssion/ LG/ Haier
4All as per item No. 02 above but for 1.5 ton Split type Air conditioner [Notes : (a) Capillary, drier, copper tubing etc are inclusive in unit rate. (b) New compressors will be purchased from authorised dealer only. (c) Unserviceable compressor either cut open or sealed unit have to be replaced by new one
5All as per Item No 03 above but for air conditioner window / split type 2 ton capacity
6Repair to Air conditioner window type/Split type 1/1.5/2 ton capacity by testing the leakage in system by filling of Nitrogen gas upto 300 PSIG and repairing of leaking spot/joints with gas welding work, cleaning and flushing out the complete system with gas, supply and replacing of drier/filter, making the complete system leak proof, vacuuming the system and charging of gas as existing andtesting etc complete all as specified & directed (Note : Drier capillary and copper tubing are inclusive in unit rate)
7S&F in replacement of blower Motor 1/5 or 1/6 HP 230V AC, 50 Hz suitable for Air conditioner window type 1.5 ton capacity blower motor complete all as directed and specified
8S&F in replacement of blower Motor 0.2/0.25 HP for Air conditioner split type 1.5 ton/2 ton complete and as directed and specified (Make - GE/Crompton/Polar)
9M & L for repair to blower Motor1/6 HP to 0.25 HPwith super enamelled copper wire of existing size suitable for Air conditioner window type / split type complete all as directed and specified
10M& L for repair to PCB circuit in air conditioner split type all as specified & directed.
11S&F in replacement ofpower contactor 240V AC, 50 Hz 16 - 25 Amps range (Make- L&T/Bhartiya cutler hamme)
12Supply and fixed in replacement of power contactor 415V AC, 50 Hz 15 Amps (Make - L&T Type MK-I/BCH or as approved)
13M&L for painting of chasis/body of AC with one coat of synthetic enamel paint by spray painting of approved make including preparation of surface and one coat of aluminium paint to outer cover.
14Supply only following spare parts for window type AC capacity 1.5/2 ton : -
15Capacitor 4 mfd
16Running capacitor 36 mfd AC
17Starter capacitor 80/100 mfd
18Relay any make and type as approved
19Over load protector
20Thermostat
21Cooling coil
22Filter pad made of Jute
23Condensers coil
24Selector switch
25Wiring kit
26Front Panel of window AC any make of 1.5/2TR
27Blower
28M&L for Stands for Discharge unit of Split type AC/ Desert coolerstand etc. as per requirement and directed by Engr -in-charge
29S&F in replacement indoor unit of AC 1.5 ton capacity split type of approved make as directed (Note-Old unit to be deposited in MES store yard)
30DESERT COOLER
31S&F desert cooler pump suitable for desert cooler operating on SP 230 Volts, 50 HZ AC after and including taking out existing defective pump of any type & connection complete all as specified & as directed.(Make : As approved by GE)
32S&F Desert cooler fan motor operating on SP 230 Volts, 50 HZ, AC 1/7HP with fan metal blade and mounting Kit complete after and including taking out existing fan motor all as directed.(Make : Cool Home/Khaitan/Crompton)
33M&L for scraping down and removing existing paint, preparation of surface and painting the entire/complete body of desert cooler, inside and outside, by sprayer withtwo coats of approved synthetic enamelpaint and writing SM/ MES No. with black or white synthetic enamel paint complete all as specified & directed
34M&L for replacement of desert cooler fan regulator with selector switch suitable for 3 Speed fan motor SP 230V AC.
35M&L for replacement of PVC pipe 15mm bore standard quality of desert cooler complete with fixing arrangement, all as specified and directed.
36M&L for replacement of wool pad of desert cooler of 3000 CUM/Hour/4500Cum/hr/6000 cun/hour capacity & suitable size as approved by EIC.
37M & L for winding of desert cooler exhaust fan motor with supper enameled copper wire of existing size and gauge incl varnising and replacement of defective bush/bearing complete
38M & Linreplacement offront panel of desert cooler capacity 4000/6000 CFMwith PVC front panel including horizental/vertical louvers complete
39WATER COOLER
40Dismantling of electric connection and water connection of water cooler opening the condensor fan motor blade, electrical accessories and spare parts of system carefully servicing of serviceable parts replacement of U/S parts oiling of fan motor etc reassembling all spare parts incl rewiring of internal connection of water cooler, testing and commissioning complete all as specified. (Note: Worn out or unserviceable spare parts to be replaced shall be measured and paid separately as supply only under respective item.)
41Removing burnt/defective sealed compressor unit of any make from water cooler cap 40 Ltrs/hr by cutting of suction and discharge lines and unscrewing the foundation nuts & bolts etc, supply and fixing new sealed compressor unit Make as existing or equivalent in kirloskar or tecumsehby tightening the foundatopn nuts and bolts and connecting suction and dischrage line with gas welding work etc complete. [Note:- (i) Cost of transportation shall be deemed to be included in the quoted rates. GI fitting damaged while taking out/fixing back water coolers shall be replaced by the contractor at his own cost. (ii) All new compressor shall be purchased from authorised dealer only. (iii) Capillary, drier, filter strainer are inclusive in unit rate. (iv) Old compressor either cut open or sealed have to replaced with new one.]
42All as per item No 28 above but water cooler Cap 60 Ltrs/hr
43All as per item No 28 above but water cooler cap 150 Ltrs/hr.
44M&L for replacement of Rubber hose pipe of 20mm bore with clips for outlet tray of water cooler of length 1.5 Mtr long approx. complete
45M&L for replacement of PVC sheet rubber bedding and lock of top cover of water cooler by screwing/welding MS sheet of top cover complete all as directed
46M&L for replacement of PVC connection rigid type 18” long 15mm bore, with adopter at both ends complete.
47M&L for making the system leak proof and charging of gas Freon 12/22 as required in water cooler of capacity 40/60 Ltr including replacement of drier and capacity tube and testing on load complete all as directed
48All as per item No. 32 above but of capacity 120/150 ltrs.
49M&L for scraping old painted surface of water cooler any capacity and painting with two coats of synthetic enameled paint including writing SM/MES No with black paint with minimum 25 mm size of letters as directed
50M&L for replacement of old condenser fins with new, forced air-cooled including necessary brazing work for water cooler of any capacity including testing for leakage complete.
51S&F in replacement of condenser fan motor of cap 1/35 HP with fan blade all as directed
52M & L for winding of condenser fan motor of cap upto 1/8 HP with super enamelled copper wire of existing size including replacement of bush and fan blade incl painting complete all as directed
53S&F in replacement of push cock/lift cock brass chromium plated 15 mm bore.
54M&L for replacement of flexible PVC pipe of followingsizes for the drainage of waste water of water coolers or concealing the copper tubing of split AC and condensed moisture of air conditions all as directed.
5540mm dia
5650mm dia
5760mm dia
58Detection and rectification of leakage of storage tank of water cooler by brazing soldering/welding as required at site or work shop testing for leak proof complete all as directed. [Note : (a) Nipple adoptor if required deemed to be included in unit rate. (b) Push cock, float valve etc if required will be measured and paid separately. (c) Changing of rubber/plastic packing is incl in unit rate]
59Taking out the drain tray with PVC pipe of water cooler, electroplating (chromium plating) of drain tray after repair by denting/painting and including replacement of new PVC pipe of suitable size and length and refixing back all as directed.
60Supply only the following items for water cooler :-
61Starting capacitor 60/80 mfd
62Running capacitor 10 mfd
63Thermostat
64Relay over load kit
65Relay
66Over load protector 1022
67Wiring kit
68Strainer/filter drum type/pen type
69Door gasket
70Float valve 1/2" including assembly brass made.
71REFRIGERATORS
72Repair maint of refrigerator 165 to 310 ltrs capacity cleaning of indoor panel, servicing of serviceable parts, replacement of worn out parts, testing for smooth functioning of refrigerator all as directed. [Note: Worn out or unserviceable spare parts to be replaced shall be measured and paid separately as supply only under respective item.]
73M&L for detection of leakage and repairing thoroughly to ensure the complete system leak proof and charging of refrigerant gas with appropriate quality incl necessary brazing, welding, testing and commissioning complete all as directed.[Note : Capillary, drier and copper tubing/filter strainer are inclusive in unit rate.]
74Dismantling of unserviceable sealed compressor unit from refrigerator 165 - 310 ltrs capacity and replacing with new compressor as existing capacity and model and charging of refrigerant gas of appropriate qty and testing for smooth functioning complete all as specified. [Make - Kirloskar or equivalent approved] [Note : (a) New compressor will be purchased from authorised dealer only. (b) Capillary, drier and additional copper tubing are included in unit rate. (c) Old compressor either cut open or sealed to be replaced with new one.
75Supply only the following item for refrigerators as per sample :
76Thermostat switch
77Relay box type
78Door gasket
79Cooling coil
80Condensing coil
81M&L for repair to damage body/ legs & bottom sheet/door by adding extra sheet, brazing /soldering and spray painting of refrigerator including preparation of surface of refrigerator by removing old existing paint with two coats of spray painting by duco paint (approved quality) complete all as directed.
82VOLTAGE STABILIZER
83M&L for opening unserviceable automatic voltage stabilizer for repair,detection of fault and its repair cleaning of serviceable parts, replacement/repair of unserviceable or worn out parts soldering of terminal connection and testing after repair, painting with one coat of synthetic enamel paint externally all as specified including sign writing "AGE E/M New Cantt" all as directed any make:-[Note: (a) Replacement of new parts/worn out parts in lieu of unserviceable/worn out parts shall be measured and paid separately.(b) The flexible 3 core cable, 40/.0076, 23/.0076, 70/.0076 to be provided at least 1.5 RM is included in unit rate.]
84Capacity 5 KVA/4 KVA
85Capacity 3 KVA.
86Supply only the following spare parts suitable for automatic voltage stabilizer of any make and capacity :-
87Volt meter (0-300 volts)
88Control relay
89IC controlled circuit for 5KVA/4 KVA
90IC controlled circuit for 3 KVA
91Control transformer
92Low/high voltage cut off and TDR system
93Main transformer for 5 KVA/4 KVA
94Main transformer 3 KVA
953 pin plug top 16 amp make Anchor
96M&L for rewinding of boost/buck transformer of stabilizer with copper wire of existing gauge and same number of turn with best quality insulating material including testing complete and refixing back electrically and mechanically all as directed and specified by Engr-in-Charge of following capacity :-
97Capacity 5 KVA/4 KVA
98Capacity 3 KVA
99S&F in replacementof 5 KVA stabilizer 230 volts Single phase (Note-Old to be deposited in MES store yard). (Make : Blue star/Vinitec/Brentford/Automatic Electric)
100Ceiling Fan, Exhaust Fan
101M&L for rewinding of stator complete with super enameled copper winding wire of existing gauge/ weight of copper coil, quick varnishing, oiling, greasinginsulating materials including replacement of worn out parts like u/s cotter pin, nut, screw, check nuts and bolts as required incl. cleaning of body, and testingof the following size of fans of any make complete all as specified and directed. Note - (A) Fans to be collected by the contractor at their own arrangement from AGE E/M store forrepair/rewinding and to be deposited at same place after making serviceable duly tested. (B) Aditional spare parts as required to make the serviceable of same will be measured and paid separately under respective items of schedule here in below:-
102Ceiling fan of 1200 mm sweep
103Ceiling fan of 1400 mm sweep
104Exhaust fan of 230 mm sweep
105Exhaust fan of 300 mm sweep
106Exhaust fan of 380 mm sweep
107Exhaust fan of 450 mm sweep
108Wall fan/cabin/Pedestal of 400 mm sweep
109Supply & fixing in repair the following items to incorporate the item No. 57.01 to 57.07 as mentioned above :-
110Ball bearing of ceiling/exhaust fan of any size of exactly similar as existing in fan complete all as specified and directed. (Make-NBC/SKF)
111U" shape shackle clamp assembly made out of MS flat iron incl checknut, bolts, screws, washer, split pin, lock nut, rubber reel etc. suitable to the down rod pipe and connecting complete all as specified and directed.
112Capacitor 2.5 Mfd, 440 Volt AC complete all as specified and directed. Make - Asian/Usha/Epcos of siemens /Havells or as approved by GE
113Capacitor 3.15 Mfd, 440 Volt AC complete all as specified and directed. Make - Asian/Usha/Epcos of siemens /Havells or as approved by GE
114PVC insulated, sheathed flexible copper conductor cable in three core of size 23/0.0076 from connector to the ceiling rose complete all as specified and directed.
115Capacitor clip as per existing complete all as specified and directed.
116Canopy for ceiling fan suitable for any sweep/make as required incl. screw complete all as specified and directed.
117S&Fin replacement of existing worn out with ceiling rose 3 pin/PVC/ polycarbonate, isolated body with colour ring complete all as specified and directed .
118S&F Iinreplacement of ISI Marked, medium 5 step type fan regulator 80 Watt, 240 VAC for replacement of existing worn out complete all as specified and directed .
119M&Lfor Spray painting of stained/rusted/corroded Ceiling fan/Exhaust fan complete body with one coats of synthetic enamel white/smoke gray paint incl writing of MES No over one coat of primer all as specified and directed.
120S&F in replacement of MS louvers shutters on wall suitable for exhaust fan of following sizes incl. suitable size of nut, bolts & washercomplete all as specified and directed.:-
121300 mm sweep
122450 mm sweep
123M & L for servicing of ceiling fans at site, oiling, greasing and checking of fan hook for damage spilt pin, nut bolt, rubber reels and down rod including proving new split pin and replacement of damage nut bolt and down rod complete all as specified and directed. Note: (i)replacement of down rod measure and paid seperately in relevant items
124S&F in replacement Mild steel"Medium grade" 15mm dia pipe down rod of required length with makingsplit, holes, cut etc at both end of pipe as required for hanging of C/fan incl. painting of rod with two coats of synthetic enamel white paint over one coat of primer along with U" shape shackle clamp assembly made out of MS flat iron incl checknut, bolts, screws, washer, split pin, lock nut, rubber reel complete all as specified and directed.
125S&F in repair fan hook suitable for 40 mm dia pipe, made out of MS flat iron size 50x6 mm incl. suitablesize of nut, bolt & washer complete all as specified and directed.
126DEEP FREEZERS
127Repair to Deep Freezer of any make and capacity, by supply and fixingsealed compressor unit of existing make and capacity, in replacement including taking out existing unserviceable sealed compressor unit and including necessary brazing work, making the system leak proof, and charging of gas F-12 and testing complete all as directed.
128M&L for making the system leak proof and charging of gas F-12 as required in Deep Freezer of any make capacity including replacement of drier and capillary tubing and testing on load complete all as directed.
129Supply and fixed in replacement of relay any type for Deep freezer as directed by Engr-in-Charge. (Make – Danfoss/Godrej/Ranutrol)
130Supply and Fixed in replacement of thermostatic switch for DEEP FREEZER of any cap.
131M&L for replacement of Cable 3 core flexible heavy duty copper cable of size 4 sqmm of AC , Water Cooler,stabilizer etc.(Make-Plaza/Finolex /Polycab)
132M&L for shifting/installing Split type Air conditioner of any capacity complete with piping and copper tubing arrangements including fixing the suction unit on wall and making good as existing as well as making electric connections all as directed by Engr-in-charge. Note :- Copper tubing ,drain pipe and other insulation material measured under relevant item).
133S&F in repair Metal clad plugs & sockets three pin for AC of 20 amp rating
134S&F in repair of metal plug top 20 Amps(Make : Anchor or equivalent as approved by GE)
135Supply and Refilling gas R-22/R 134/R410
136S&F insulation of copper tubing wherever required complete all as specified & directed by Engr -in - Charge. Note : Insulation of cold&return air copper tuning measured as one running meter.
137S & F Copper pipe 16mm dia with insulation for split AC complete all as specified & directed by Engr -in - Charge.
138S & F Copper pipe 12mm dia with insulation for split AC complete all as specified & directed by Engr -in - Charge.
139WINETR APPLIANCES
140Taking down existing geyser any capacity/ type after suitable disconnecting all electrical and water supply connection, removing geyser to E/M store, opening and dismantling the complete geyser, cleaning all serviceable parts completely including descaling the geyser, for replacing the defective/wornout parts, reassembling the geyser, testing for proper functioning, transporting to& refixingin original location i.e in the same in position, reconnecting the geyser with electricsupply and water supply line and testing complete all as specified and directed. Note :-(i) Parts/sparesrequired for replacement shall be measured and paid separately. (ii) Unit rate quoted shall be deemed to include minor items i.e. nut bolts, screws, lugs etc .
141S&F in repair Heating element Square, threaded/ screwed type 1500 watt ISI markedcomplete all as specified and directed. Make Theeta/ Bajaj/ Hot top/Daspass or equivalent as approved.
142S&F in repair Heating element cup type 1500 watt (ISI marked) complete all as specified and directed.Make - Bajaj/ Dass Pass/ Threeta or equivalent approved.
143S&F in repair Heating element threaded/screwed type 2000 watt (ISI marked) suitable markedcomplete all as specified and directed. Make - Bajaj/Theeta/Hot top/ Daspass or equivalent as approved.
144S&F in repair Heating elementcup type 3000 watt (ISI marked) complete all as specified and directed. Make - Bajaj/Theeta/Hot top/ Daspass or equivalent as approved.
145S&F in repair Thermostat suitable for geyser range 20 degree to 80 degree (ISI marked) complete all as specified and directed.Make-Thermoking/TTE,Elcon/ Expo/ Antriksh or equivalent approved.
146S&F in repair PVC connection cotton braided heavy duty with brass union/coupling of length 450 mm with rubber washer suitable for 15 mm pipe complete all as specified and directed..
147S&F in repair Hot water outlet connection made of chromium plated flexible tubing for 15 mm bore pipe complete all as specified and directed.
148S&F in repair Indicator lamp assembly with bulb with long lead suitable for geysers round or square type as sample kept in GE’s office complete all as specified and directed..
149S&F in repair PVC insulated flexible wire three core 2.5 sqmm copper conductor heavy duty complete all as specified and directed..
150S&F in repair Apperture plate assembly suitable for25 ltrs geyserscomplete all as specified and directed.
151S&F in repair Apperture plate assembly uitablefor 50 ltrs geysers complete all as specified and directed.
152S&F in repair Inner copper tank made out of 0.8mm(min.)for 25 ltrs geyser complete all as specified and directed.
153S&F in repair Outer body with red,green indicator and bottom cover as per existing size & shape of capacity 25 ltrs geyser complete all as specified and directed.
154S&F in repair 3 pin 15 amp plug top complete all as specified and directed. Make Anchor or equivalent as approved
155S&F in repair electronic sensor for thermal setting as per sample kept in GE’s office complete all as specified and directed..
156M&L for painting of geysers after scraping, cleaning and preparing surface for painting and painting with two coats of white enameled paint of approved make and sign writing MES No etc complete all as specified and directed for the following capacity :-.
15725 Ltrs capacity
15850 Ltrs capacity
159Repair of leakage of inner tank 25/50 ltr capacity geyser by brazing/soldering, testing including cutting of nut, bolt as required with gas welding cutter and providing new nut, bolts, washers etc complete all as specified and directed.
160S&F in repairs Chromium plated brass stop cock 15 mm bore, screwed down, high pressure with crutch or butterfly handle complete all as specified and directed.
161S&F in repairs MCB DP 32 amp, 230 volt, AC , 10 KAwith indication & enclosure complete all as specified and directed.
162S&F in repairs mild steelfoundation nuts, bolts & washers heavy duty for fixing of geyser including grouting in wall complete all as specified and directed. .
163S&F in repair socket outlet 3 pin, 15 Amp, flush type complete all as specified and directed. Make : Anchor or equivalent as approved.
164S&F in repairtwo pin and earth plug and socket sheet metal enclosurewith one single pole MCB 20 amp rating, 240 volt,C" series,10 KA breaking capacity complete all as specified and directed.
165S&F in repairs MCB single pole, 10-32 amps rating 240 volts , "C" series 10 KA breaking capacity and making connection complete as directed.
166M&L in replacement submain wiring with two single core FRPVC insulated unsheathed stranded copper conductor cable 4 Sqmm in existing concealed rigidconduitand one single core PVC insulated stranded copper conductor cable 2.5 sqmm as continuous earth wire and connected to earth dolly complete all as specified and directed. NOTE : Two single core cable of 4 sqmm and one 2.5 sqmm earth wire shall be measured as 01 RM length.
167M&L for Non return valve verticletype screwed for both ends with 15mm bore GI pipe.complete all as specified and as directed.
168S&F in repair fusible plug steel nut complete all as specified and directed.
169S&F in repair PVC insulated flexible wire 1.5 sqmm copper conductor complete all as specified and directed..
170S&F in repair Timmer suitable for Hevalls geyser (ISI marked) complete all as specified and directed.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail