Supply, Installation, Testing And Commissioning Of 125Kva Dg Set And Allied Electrical Works At Amenity Center. Supply, Installation,Testing And Commissioning Of 125Kva Dg Set And Allied Electrical Works At Amenity Center. , 125Kva Dg Set , Od34885/2022_2, Ernakulam-Kerala

Cochin University Of Science And Technology-CUSAT has published Supply, Installation, Testing And Commissioning Of 125Kva Dg Set And Allied Electrical Works At Amenity Center. Supply, Installation,Testing And Commissioning Of 125Kva Dg Set And Allied Electrical Works At Amenity Center. , 125Kva Dg Set , Od34885/2022_2. Submission Date for this Tender is 15-06-2022. Coats and Jackets Tenders in Ernakulam Kerala. Bidders can get complete Tender details and download the document.




Tender Notice

32523775
Supply, Installation, Testing And Commissioning Of 125Kva Dg Set And Allied Electrical Works At Amenity Center. Supply, Installation,Testing And Commissioning Of 125Kva Dg Set And Allied Electrical Works At Amenity Center. , 125Kva Dg Set , Od34885/2022_2
Open Tender
Indian
Kerala
Ernakulam
15-06-2022

Tender Details

Supply, Installation, Testing And Commissioning Of 125Kva Dg Set And Allied Electrical Works At Amenity Center. Supply, Installation,Testing And Commissioning Of 125Kva Dg Set And Allied Electrical Works At Amenity Center. , 125Kva Dg Set , Od34885/2022_2023 : Supply Installation, Testing And Commissioning Of 125 Kva 100 Kw A.C. 3 Phase 415 V, 1500 Rpm 0.8 Power Factor, 50 Hz, Silent Diesel Captive Generation Unit Comprising Of Engine Coupled Directly To Alternator Mounted On A Rigid Bed Plate With Suitable Acoustic Enclosure And Complete With Standard Control Panel, Battery Leads And Fuel Tank Etc , Od34889/2022_2023 : Supplying, Fixing, Testing And Commissioning Of Exhaust Pipes Of Following Sizes Of Ms &Apos;C&Apos; Class Along With Necessary Clamps, Fittings Such As Bends, Tees Etc And 50X50x3 Mm Angle Support For The Pipe.&Lt;Br&Gt;Dg Set Exahust Piping Of Nominal Size - 125 Mm Dia, 3 Mm Thickness , 14.9 : Providing And Laying In Position Cement Concrete 1 :3:6 (1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 40 Mm Nominal Size) In Foundation Of Pump, Dg Set Etc. Including Form Work Etc. As Required. , Cabling And Termination , 90.12.1.33 : Supply & Laying Of One Number Pvc Insulated And Pvc Sheathed Armoured Aluminium Powercable Of 1.1Kv Grade Of The Following Sizes In Ground Including Excavation Of Trench Of Size 35 X 75 Cm, Refilling The Trench Etc. As Required But Excluding Sand Cushioning And Protective Covering (In Ordinary Soil). , 90.12.7.33 : Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armoured Aluminium Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages , Colour Washing Etc. As Required. , 90.12.7.34 : Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armoured Aluminium Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages , Colour Washing Etc. As Required. , Od34893/2022_2023 : Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armoured Copper Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages , Colour Washing Etc. As Required.&Lt;Br&Gt;6 Core 2.5 Sq Mm With Factory Made Clamp , Od34896/2022_2023 : Supply And Laying Of One Number Additional Pvc Insulated And Pvc Sheathed Armoured Copper Powercable Of 1.1Kv Grade Of The Following Sizes In Ground In The Same Trench In One Tier Horizontal Formation Including Wideningthe Trench By 20 Cm, Refilling The Trench Etc. As Required But Excluding Sand Cushioning And Protective Covering (In Ordinary Soil)&Lt;Br&Gt;6 Core 2.5 Sq Mm , Od34900/2022_2023 : Supply And Laying Of One Number Additional Pvc Insulated And Pvc Sheathed Armoured Copper Powercable Of 1.1Kv Grade Of The Following Sizes In Ground In The Same Trench In One Tier Horizontal Formation Including Wideningthe Trench By 20 Cm, Refilling The Trench Etc. As Required But Excluding Sand Cushioning And Protective Covering (In Ordinary Soil)&Lt;Br&Gt;2 Core 2.5 Sq Mm , Od34901/2022_2023 : Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armoured Copper Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages , Colour Washing Etc. As Required.&Lt;Br&Gt;2 Core 2.5 Sq Mm With Factory Made Clamp , 9.1.26 : Supplying And Making End Termination With Brass Compression Gland And Aluminium Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade As Required.3 1/2 X 150 Sq. Mm (50Mm) , 9.1.27 : Supplying And Making End Termination With Brass Compression Gland And Aluminium Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade As Required.3 1/2X 185 Sq. Mm (57Mm) , 9.1.29 : Supplying And Making End Termination With Brass Compression Gland And Aluminium Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade As Required.3 1/2X 240 Sq. Mm (62Mm) , 9.4.26 : Supplying And Making Straight Through Joint With Heat Shrinkable Kit Including Ferrules And Other Jointing Materials For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade As Required.31/2 X 240 Sq. Mm , 90.12.24.1 : Supply Of Superior Quality Copper Tubular Cable Socket And Making Core Termination Of Cables Of The Following Sizes Including Crimping Etc. As Required. , Od34903/2022_2023 : Dismantling Of Existing 3.5X240 Sqmm Aluminium Armoured Cable From Existing Ssb , Earthing , Od34888/2022_2023 : Supplying And Laying 25 Mm X 3 Mm Copper Strip At 0.50 Metre Below Ground As Strip Earth&Lt;Br&Gt;Electrode, Including Connection/ Terminating With Nut, Bolt, Spring, Washer Etc. As Required.&Lt;Br&Gt;(Jointing Shall Be Done By Overlapping And With 2 Sets Of Brass Nut Bolt & Spring Washer Spaced At 50Mm) , 5.2 : Earthing With G.I. Earth Pipe 4.5 Metre Long, 40 Mm Dia Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Etc. With Charcoal/ Coke And Salt As Required , Od34891/2022_2023 : Providing And Fixing 25 Mm X 3 Mm Copper Strip In 40 Mm Dia G.I. Pipe From Earth Electrode Including Connection With Brass Nut, Bolt, Spring, Washer Excavation And Re-Filling Etc. As Required. , Od34894/2022_2023 : Providing And Fixing 25 Mm X 3 Mm Copper Strip On Surface Or In Recess For Connections Etc. As Required. , Amf Panel , 90.14.1.2 : Fabrication, Supply, Conveyance, Installation Testing And Commissioning Of Floor Or Wall Mounting, Dust And Vermin Proof, Cubicle Type Mv Panel Board Comprising Of The Following Components/ Devices & Complying To Is 8623.<Br> Fabrication Of Fully Partitioned, Dust And Vermin Proof Enclosure For Panel Assembly As Per Form 4 Of Is 8623 (With Latest Amendments) Using Crca Sheet As Per Approved Design And Requirement, With Front And Rear Access Facility, Bus Bar Chambers, Hinged Doors For All Switch Gear Compartments, Earthing The Doors Using 4 Sq Mm Braided Copper Conductor, Providing Necessary Cut-Outs For Mounting Meters, Relays, Indication Lamps, Bus Bar Interconnection Etc, Detachable Covers For Bus Bar Chamber And Cable Alley, Powder Coating The Assembly After Subjecting To 7 Tank Process Etc As Required. Crca Sheet Alone Be Used For The Fabrication. Angles/ Flats/ Slotted Angles Etc Shall Not Be Used For The Fabrication Of Panel Assembly. The Measurments Will Be Taken The Area Of The Complete Sheets Used For Panel Board Including Partitions, Folding, Shrouding Etc. , Od34886/2022_2023 : Supply, Installation, Testing And Commissioning Of Following Items In An Existing Amf Panel.2 Nos 200 A 4P Power Contactor With Control Contactors, Add On Blocks, Mechanical Interlock Plates Etc, Amf Relay, Auto Manual Selector Switch With Control Mcb&Apos;S, On Delay Timer, 12V Battery Charger, Plug In Relays, Ov Uv Relays, Illuminated On Push Button And Ordinary Off Push Button, Multi Function Meter (Vaf, Pf) With 3 Nos 200/5A Resin Cast Metering Ct&Apos;S And Control Mcb Etc, 2 Set Ryb Indication With Control Mcb And All Control Wiring Etc. , 90.14.2.1 : Supply And Providing 2Mm Smc Sheet As Shrouding For Bus Interconnection / Terminations Etc. Including Required Nut & Bolt Etc. , 90.14.3.1 : Supply And Providing Heavy Duty A Section Neoprene Gasket In The Panel Board , 90.14.4 : Supply And Fabrication Conveyance And Installation Of Base Frame Of Panel Board Using75 X 40 Mm Rolled Steel Channel (Ismc) , Od34897/2022_2023 : Supplying And Fixing 200 A, Tpn, Aluminium Busbars (25 X 10 Mm) In The Existing Panel Board. , 90.14.7 : Supply And Providing Copper Earth Bus In The Panel Board , Od34902/2022_2023 : Providing And Fixing Following Capacity Tp&N Disconnector Switch Unit Inside The Existing Panel Board Including Drilling Holes In Cubicle Panel, Making Connections, Etc. As Required.&Lt;Br&Gt;200 Amp Tp&N , 2.1.5 : Providing And Fixing Following Capacity Tp&N Disconnector Fuse Switch Unit Inside The Existing Panel Board With Isi Marked Hrc Fuses Including Drilling Holes In Cubicle Panel, Making Connections, Etc. As Required.160 Amp Tp&N , 2.1.6 : Providing And Fixing Following Capacity Tp&N Disconnector Fuse Switch Unit Inside The Existing Panel Board With Isi Marked Hrc Fuses Including Drilling Holes In Cubicle Panel, Making Connections, Etc. As Required.200 Amp Tp&N , Civil Works , 4.1.6 : Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level:1:3:6 ( 1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 40 Mm Nominal Size) , 4.1.8 : Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level:1:4:8 (1 Cement : 4 Coarse Sand : 8 Graded Stone Aggregate 40 Nominal Size) , 10.1 : Structural Steel Work In Single Section, Fixed With Or Without Connecting Plate, Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer All Complete. , 10.16.1 : Steel Work In Built Up Tubular (Round, Square Or Rectangular Hollow Tubes Etc.) Trusses Etc., Including Cutting, Hoisting, Fixing Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete.Hot Finished Welded Type Tubes , 13.52.1 : Finishing With Epoxy Paint (Two Or More Coats) At All Locations Prepared And Applied As Per Manufacturers Specifications Including Appropriate Priming Coat, Preparation Of Surface, Etc. Complete.On Steel Work , 51.18.12.7 : Providing And Fixing G.I. Pipes Complete With G.I. Fittings (Cost Of Fittings To Be Paid Separately)External Work - 65 Mm Nominal Dia , Miscellaneous Items , Od34884/2022_2023 : Supply And Providing 2Mm Thick Synthetic Pvc Fire Retardent Insulating Mat With 3.3Kv Dielectric Strength Conforming To Relevant Iss , Od34887/2022_2023 : Supply And Providing Fire Bucket (9Ltr Capacity) Painted With Post Office Red Colour With Primer Coat Of Red Oxide And Written With White Paint &Apos;Fire&Apos; And Filled With Sand And Mounted In Standing Bracket In Wall , Od34890/2022_2023 : Supplying And Fixing Abc Type Fire Extinguisher 4 Kg. , Od34892/2022_2023 : Painting Letters Or Figures With Enamel Paint As Identification Marks To Sb, Db,Panel Boards Etc As Required , Od34895/2022_2023 : Electrical Inspectorate Fees (Amount Will Be Paid Against Original Reciepts) , Od34898/2022_2023 : Expenses For Preparation And Submission Of Necessary Documents, Forms, Scheme, Drawings And Certificates Etc For Getting Approval And Energization Order From Ei For Dg Set. First Computer Copy A3 Sheet And Additional Copy A3 Sheet , Od34899/2022_2023 : Digging Existing Cable Trench Of Size Approx 40X75cm , For Taking Out The Existing 240 Sqmmpvc Insulated And Pvc Sheathed/ Xlpe Aluminium Conductor Cable Of 1.1 Kv Etc As Required.

Key Value

Document Fees
INR 3250 /-
EMD
INR 23400.0 /-
Tender Value
INR 15.60 Lakhs /-

BOQ Items

Work Name : Supply, Installation, Testing and Commissioning of 125KVA DG Set and allied electrical works at Amenity center
Sl. No. Item Description
1125KVA DG SET
2od34885/2022_2023 : Supply Installation, Testing and commissioning of 125 KVA 100 KW A.C. 3 Phase 415 V, 1500 RPM 0.8 power factor, 50 Hz, Silent Diesel Captive Generation Unit comprising of Engine coupled directly to Alternator mounted on a rigid bed plate with suitable Acoustic Enclosure and complete with standard control panel, battery leads and fuel tank etc
3od34889/2022_2023 : Supplying, fixing, testing and commissioning of exhaust pipes of following sizes of MS 'C' class along with necessary clamps, fittings such as bends, tees etc and 50x50x3 mm angle support for the pipe.<br>DG Set Exahust piping of nominal size - 125 mm dia, 3 mm thickness
414.9 : Providing and laying in position cement concrete 1 :3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) in foundation of pump, DG set etc. including form work etc. as required.
5CABLING AND TERMINATION
690.12.1.33 : Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium powercable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).
790.12.7.33 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.
890.12.7.34 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.
9od34893/2022_2023 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured copper power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.<br>6 core 2.5 sq mm with factory made clamp
10od34896/2022_2023 : Supply and Laying of one number additional PVC insulated and PVC sheathed armoured copper powercable of 1.1KV grade of the following sizes in ground in the same trench in one tier horizontal formation including wideningthe trench by 20 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil)<br>6 core 2.5 sq mm
11od34900/2022_2023 : Supply and Laying of one number additional PVC insulated and PVC sheathed armoured copper powercable of 1.1KV grade of the following sizes in ground in the same trench in one tier horizontal formation including wideningthe trench by 20 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil)<br>2 core 2.5 sq mm
12od34901/2022_2023 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured copper power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.<br>2 core 2.5 sq mm with factory made clamp
139.1.26 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 150 sq. mm (50mm)
149.1.27 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 185 sq. mm (57mm)
159.1.29 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 240 sq. mm (62mm)
169.4.26 : Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.31/2 X 240 sq. mm
1790.12.24.1 : Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required.
18od34903/2022_2023 : Dismantling of existing 3.5x240 sqmm aluminium armoured cable from existing SSB
19EARTHING
20od34888/2022_2023 : Supplying and laying 25 mm X 3 mm copper strip at 0.50 metre below ground as strip earth<br>electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required.<br>(Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm)
215.2 : Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required
22od34891/2022_2023 : Providing and fixing 25 mm X 3 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required.
23od34894/2022_2023 : Providing and fixing 25 mm X 3 mm copper strip on surface or in recess for connections etc. as required.
24AMF PANEL
2590.14.1.2 : Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623.
Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc.
26od34886/2022_2023 : Supply, installation, testing and commissioning of following items in an existing AMF panel.2 Nos 200 A 4P power contactor with control contactors, add on blocks, mechanical interlock plates etc, AMF Relay, Auto manual selector switch with control MCB's, On Delay Timer, 12V battery charger, Plug in relays, OV UV relays, Illuminated On push button and Ordinary OFF push button, Multi function meter (VAF, PF) with 3 Nos 200/5A resin cast metering CT's and control MCB etc, 2 set RYB indication with control MCB and all control wiring etc.
2790.14.2.1 : Supply and providing 2mm SMC sheet as shrouding for bus interconnection / terminations etc. including required nut & bolt etc.
2890.14.3.1 : Supply and providing heavy duty "A" section neoprene gasket in the panel board
2990.14.4 : Supply and fabrication conveyance and installation of base frame of panel board using75 x 40 mm rolled steel channel (ISMC)
30od34897/2022_2023 : Supplying and Fixing 200 A, TPN, aluminium busbars (25 x 10 mm) in the existing panel board.
3190.14.7 : Supply and providing copper earth bus in the panel board
32od34902/2022_2023 : Providing and fixing following capacity TP&N disconnector switch unit inside the existing panel board including drilling holes in cubicle panel, making connections, etc. as required.<br>200 Amp TP&N
332.1.5 : Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.160 Amp TP&N
342.1.6 : Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.200 Amp TP&N
35CIVIL WORKS
364.1.6 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size)
374.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)
3810.1 : Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
3910.16.1 : Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes
4013.52.1 : Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer"s specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work
4151.18.12.7 : Providing and fixing G.I. pipes complete with G.I. fittings (Cost of fittings to be paid separately)External work - 65 mm nominal dia
42MISCELLANEOUS ITEMS
43od34884/2022_2023 : Supply and Providing 2mm thick synthetic PVC fire retardent insulating mat with 3.3KV dielectric strength conforming to relevant ISS
44od34887/2022_2023 : Supply and Providing fire bucket (9ltr capacity) painted with post office red colour with primer coat of red oxide and written with white paint 'FIRE' and filled with sand and mounted in standing bracket in wall
45od34890/2022_2023 : Supplying and Fixing ABC Type Fire Extinguisher 4 kg.
46od34892/2022_2023 : Painting letters or figures with enamel paint as identification marks to SB, DB,panel boards etc as required
47od34895/2022_2023 : Electrical Inspectorate fees (Amount will be paid against original reciepts)
48od34898/2022_2023 : Expenses for preparation and submission of necessary documents, forms, scheme, drawings and certificates etc for getting approval and energization order from EI for DG set. First computer copy A3 sheet and additional copy A3 sheet
49od34899/2022_2023 : Digging Existing Cable Trench of size approx 40x75cm , for taking out the existing 240 sqmmPVC insulated and PVC sheathed/ XLPE aluminium conductor cable of 1.1 KV etc as required.
Disclaimer :