Power Government Departments Closing in 0 days TDR #32517711

Annual Rate Contract For Maintenance Of Boiler Pressure Parts Of Stage-I And Stage-Ii Btps Under-2 Economiser Tube Jointtube Od 51 Mm, Thickness 4.8 Mm, Material: Sa 210 Gr.C Orequivalent 3 Insert At Furnace Wall, Goose Necks-Pannel & Roof Tube ( 1

Issued by Government Departments · hooghly, West Bengal
Tender Value
20.71 Lakhs
Estimated cost
Bid Submission
27 Jun 2022
0 days left
EMD
41500
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
hooghly → West Bengal
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Annual Rate Contract For Maintenance Of Boiler Pressure Parts Of Stage-I And Stage-Ii Btps Under-2 Economiser Tube Jointtube Od 51 Mm, Thickness 4.8 Mm, Material: Sa 210 Gr.C Orequivalent 3 Insert At Furnace Wall, Goose Necks-Pannel & Roof Tube ( 1 Insert = 02 Nos. Joint ) Tube Od:63.5 Mm To 69.9 Mm, Thickness From 5.1 To 6.3 Mm, Material:Sa 210 Gr. A Or Equivalent 4 Joint At Saturated Screenroof & Side Wall, Screen Tube, Primarysuperheater Tube, Secondary Superheater Tube. ( Od: 63.5 Mm, Thickness: 5 Mm Upto 6.9 Mm, Material:Sa213t11 Or Equivalnt ) 5 Joint At Reheater Tube / Insert At Furnace Wall, Goose Neck, S-Panel &Roof Tube. 6 Second Pass Scaffolding 7 Economiser Coil Liftingrepairing, Fitting & Jointing With Proper Alignment For Unit 1 & 2 ( Ifrequired For Preventive Checking Beyond Leakage Area ) 8 Primary & Secondary Superheater Coilpulling, Inspection And Proper Alignment Of Coil & Panelwith Clit And Support Welding Of Unit 1 & 2 ( If Checkingrequired For Preventive Inspection ) 9 Maintenance Of Boiler Pressure Part Stage-Ii 10 Lp Water Cleaningeconomizer Zone, Psh & Prh 11 Joint For Lnsertion Of Water Wall Tube, Cage Rear Wall Below Main Cavity & Baffle Wall Tube Below Maincavity, Size: 63.5X5.4, Mat: Bs3059 / 45S2 Or 5A210gr.C. 12 Insertion Joint For Division Wall Tubesize: 82.5X7, Mat: Bs3059 / 45S2; Or Sa210gr.C 13 Joint For Lnsertion Of Furnace Roof, Cage Rear Wall & Baffle Wall Tube Above Main Cavity, Size:63.5X4.8, Mat: Bs3059 / 620S2 Or Sa213t11 14 Joint For Insertion Of Economiser Tubesize: 38.1X3.6, Mat: Bs3o59 / 45S2 Or Sa210gr.C 15 Insertion Joint Of Psh Bottom & Middlesize:57.1X6, Mat: Bs3059 / 620S2 Or Sa213t11 16 Joint For Insertion Of Psh Top Bank Tubetube, Size: 63.5X3.6, Mat: Bs3059 / 33S2 Orsa210gr.C 17 Insertion Joint Of Prh Bottom & Middlesize: 57X3.2, Mat: Bs3059 / 620S2 Or Sa213t11 18 Joint For Lnsertion Of Prh Top Bank Tubesize: 57X3.2, Mat: Bs3059 / 620S2 Or Sa213t11 19 Joint For Lnsertion Of Plsh And Fshinlet Tube, Size: 44.5X7, Mat: Sa213t22 20 Joint For Lnsertion Of Fsh & Frh Tubesize: 50.8X3.6, Mat: Sa213t91 21 Economiser / Psh / Prh Coil Lifting, Inspection Repairing And Fitting With Proper Alignment ( If Requiredfor Preventive Inspection Beyond The Leakage Area ) 22 Platen Sh, Fsh, Frh Coil Pullinginspection And Proper Alignment Of Coil And Panel With Clit Andsupport Welding 23 Second Pass Scaffolding Per 6 Meter 24 Common Work For Stage-I&Ii 25 Stress Relieving 26 Radiography 27 Removal And Refitting Of Refractory 28 Replacement Of High Pressure Valve Size Upto 2 29 Replacement Of High Pressure Line ( 1 / 2 To 4 ) ( Unit Of 01 Number Includes Two Joints ) 30 Deinsulation & Insulation With Claddingof Wall, Casing And Pipe And Other Area Of Boiler 31 Hp Valve Welding From 50 Nb Upto 100 Nbpipe 32 Hp Valve Gland Packing Replacementupto 6 33 Hp Valve Servicingincluding Gland Packing & Bonnet Seal Replacement Upto 4 34 D-Metering Of Boiler Tubeat Any Area Of Boiler For Thickness Measurement ( Minimum Survey150 Nos. / Day ) 35 Minimum Mobilization Chargeif Total Executed Job Value Less Than Rs.15000.00 36 Vertical Scaffoldingfor Approaching Roof Tube / Reheater / Secondary Sh ( Per 6 Metervertical ) For Stage I & For Approaching Furnace / Roof Tube / Pendent Reheater / Platen / Fsh & Division Wall ( Per 6 Metervertical ) For Stage Ii 37 Horizontal Scaffolding For Approaching Platen Sh / Scw / Roof Tubes / Furnace ( Per 6Meter Horizontal ) For Stage I & For Approaching Rh / Platen Sh / Final Sh / Divisional Wall / Scw / Roof Tubes / Furnace ( Per 6 Meter Horizontal ) For Stage Ii 38 Guard Tube And Guard Plateremoval, Fabrication And Fitting 39 Build Up In Eroded Tubesas Per Requirement 40 Repairing Of Skin Casing 41 Fabrication Of Bends Of Any Degree Of Any Boiler Tube 42 Fitting And Welding Of Tube Attachment Wherever Require 43 Membrane Strip Fitting & Welding 44 Fabrication And Erection Of Steel Itemsby Ms Plate / Ms Angle / Ms Channel / I Beam Etc. 45 Boiler Metal Temp Tc & Mounting Replace 46 Thermowell Replacement In Hp Line

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 02-Jun-2022 boqcorrigendum BOQ 27-Jun-2022

BOQ

Name of Work:\"ARC for maintenance of Boiler Pressure Parts of Stage-I & Stage-II, BTPS under B&A Dept. ,BTPS,WBPDCL (for one year)”.
Sl. No. Item Description
1Maintenance of Boiler pressure part Stage-1
2ECONOMISER TUBE JOINTTube OD 51 mm, Thickness 4.8 mm, Material: SA 210 GR.C orequivalent
3INSERT AT FURNACE WALL, GOOSE NECKS-PANNEL & ROOF TUBE (1 insert = 02 nos. joint) Tube OD:63.5 mm TO 69.9 mm, Thickness from 5.1 to 6.3 mm, Material:SA 210 GR. A or equivalent
4JOINT AT SATURATED SCREENROOF & SIDE WALL, SCREEN TUBE, PRIMARYSUPERHEATER TUBE, SECONDARY SUPERHEATER TUBE.(OD: 63.5 mm, Thickness: 5 mm upto 6.9 mm, Material:SA213T11 OR EQUIVALNT)
5JOINT AT REHEATER TUBE/INSERT AT FURNACE WALL, GOOSE NECK, S-PANEL &ROOF TUBE.
6Second pass scaffolding
7Economiser coil liftingrepairing,fitting & jointing with proper alignment for unit 1 & 2 (ifrequired for preventive checking beyond leakage area)
8Primary & secondary superheater coilpulling, inspection and proper alignment of coil & panelwith clit and support welding of unit 1 & 2 (if checkingrequired for preventive inspection)
9Maintenance of Boiler pressure part Stage-II
10LP water CleaningEconomizer Zone, PSH & PRH
11Joint for lnsertion of water wall tube,cage rear wall below main cavity & baffle wall tube below maincavity,Size: 63.5X5.4, Mat: BS3059/45S2 or 5A210Gr.C.
12Insertion joint for division wall tubeSize: 82.5X7, Mat: BS3059/45S2; or SA210Gr.C
13Joint for lnsertion of furnace roof,cage rear wall & baffle wall tube above main cavity, Size:63.5X4.8, Mat: BS3059/620S2 or SA213T11
14Joint for Insertion of economiser tubeSize: 38.1X3.6, Mat: BS3O59/45S2 or SA210Gr.C
15Insertion joint of PSH bottom & middleSize:57.1X6, Mat: BS3059/620S2 or SA213T11
16Joint for Insertion of PSH top bank tubetube, Size: 63.5X3.6, Mat: BS3059/33S2 orSA210Gr.C
17Insertion joint of PRH bottom & middleSize: 57X3.2, Mat: BS3059/620S2 or SA213T11
18Joint for lnsertion of PRH top bank tubeSize: 57X3.2, Mat: BS3059/620S2 or SA213T11
19Joint for lnsertion of PLSH and FSHinlet tube, Size: 44.5X7, Mat: SA213T22
20Joint for lnsertion of FSH & FRH tubeSize: 50.8X3.6, Mat: SA213T91
21Economiser/PSH/PRH coil lifting,inspection repairing and fitting with proper alignment (if requiredfor preventive inspection beyond the leakage area)
22Platen SH, FSH, FRH coil pullinginspection and proper alignment of coil and panel with clit andsupport welding
23Second pass scaffolding Per 6 Meter
24Common work for Stage-I&II
25Stress Relieving
26Radiography
27Removal and refitting of refractory
28Replacement of high pressure valve size upto 2\"\"
29Replacement of high pressure line(1/2\"\" to 4\"\") (Unit of 01 \"Number\" includes two joints)
30Deinsulation & insulation with claddingof wall, casing and pipe and other area of boiler
31HP Valve Welding from 50 NB upto 100 NBpipe
32HP valve gland packing replacementupto 6\"
33HP valve servicingincluding gland packing & bonnet seal replacement upto 4\"
34D-metering of boiler tubeat any area of boiler for thickness measurement (minimum survey150 nos./day)
35Minimum mobilization chargeif total executed job value less than Rs.15000.00
36Vertical scaffoldingfor approaching Roof Tube/ Reheater/ Secondary SH (Per 6 MeterVertical) for Stage I & for approaching Furnace/ Roof Tube/Pendent Reheater/ Platen/FSH & Division wall (Per 6 MeterVertical) for Stage II
37Horizontal scaffolding for approaching Platen SH/SCW/ Roof Tubes/Furnace (Per 6Meter horizontal) for Stage I & for approaching RH/ platen SH /Final SH / Divisional wall/SCW/ Roof Tubes/ Furnace (per 6 meter horizontal)for Stage II
38Guard Tube and Guard PlateRemoval, Fabrication and Fitting
39Build up in eroded Tubesas per requirement
40Repairing of skin casing
41Fabrication of bends of any degree of any boiler tube
42Fitting and welding of tube attachment wherever require
43Membrane strip fitting & welding
44Fabrication and erection of Steel itemsby MS plate/ MS Angle/ MS channel/ I Beam etc.
45Boiler metal temp TC & mounting replace
46Thermowell replacement in HP line

AI Tender Summary

OUR REF NO 32517711
AUTHORITY Government Departments
TENDER VALUE 20.71 Lakhs
LAST DATE 27-06-2022
Authority
Authority Name West Bengal Power Development Corporation Limited
Work Description Annual Rate Contract For Maintenance Of Boiler Pressure Parts Of Stage-I And Stage-Ii Btps Under-2 Economiser Tube Jointtube Od 51 Mm, Thickness 4.8 Mm, Material: Sa 210 Gr.C Orequivalent 3 Insert At Furnace Wall, Goose Necks-Pannel & Roof Tube ( 1 Insert = 02 Nos. Joint ) Tube Od:63.5 Mm To 69.9 Mm, Thickness From 5.1 To 6.3 Mm, Material:Sa 210 Gr. A Or Equivalent 4 Joint At Saturated Screenroof & Side Wall, Screen Tube, Primarysuperheater Tube, Secondary Superheater Tube. ( Od: 63.5 Mm, Thickness: 5 Mm Upto 6.9 Mm, Material:Sa213t11 Or Equivalnt ) 5 Joint At Reheater Tube / Insert At Furnace Wall, Goose Neck, S-Panel &Roof Tube. 6 Second Pass Scaffolding 7 Economiser Coil Liftingrepairing, Fitting & Jointing With Proper Alignment For Unit 1 & 2 ( Ifrequired For Preventive Checking Beyond Leakage Area ) 8 Primary & Secondary Superheater Coilpulling, Inspection And Proper Alignment Of Coil & Panelwith Clit And Support Welding Of Unit 1 & 2 ( If Checkingrequired For Preventive Inspection ) 9 Maintenance Of Boiler Pressure Part Stage-Ii 10 Lp Water Cleaningeconomizer Zone, Psh & Prh 11 Joint For Lnsertion Of Water Wall Tube, Cage Rear Wall Below Main Cavity & Baffle Wall Tube Below Maincavity, Size: 63.5X5.4, Mat: Bs3059 / 45S2 Or 5A210gr.C. 12 Insertion Joint For Division Wall Tubesize: 82.5X7, Mat: Bs3059 / 45S2; Or Sa210gr.C 13 Joint For Lnsertion Of Furnace Roof, Cage Rear Wall & Baffle Wall Tube Above Main Cavity, Size:63.5X4.8, Mat: Bs3059 / 620S2 Or Sa213t11 14 Joint For Insertion Of Economiser Tubesize: 38.1X3.6, Mat: Bs3o59 / 45S2 Or Sa210gr.C 15 Insertion Joint Of Psh Bottom & Middlesize:57.1X6, Mat: Bs3059 / 620S2 Or Sa213t11 16 Joint For Insertion Of Psh Top Bank Tubetube, Size: 63.5X3.6, Mat: Bs3059 / 33S2 Orsa210gr.C 17 Insertion Joint Of Prh Bottom & Middlesize: 57X3.2, Mat: Bs3059 / 620S2 Or Sa213t11 18 Joint For Lnsertion Of Prh Top Bank Tubesize: 57X3.2, Mat: Bs3059 / 620S2 Or Sa213t11 19 Joint For Lnsertion Of Plsh And Fshinlet Tube, Size: 44.5X7, Mat: Sa213t22 20 Joint For Lnsertion Of Fsh & Frh Tubesize: 50.8X3.6, Mat: Sa213t91 21 Economiser / Psh / Prh Coil Lifting, Inspection Repairing And Fitting With Proper Alignment ( If Requiredfor Preventive Inspection Beyond The Leakage Area ) 22 Platen Sh, Fsh, Frh Coil Pullinginspection And Proper Alignment Of Coil And Panel With Clit Andsupport Welding 23 Second Pass Scaffolding Per 6 Meter 24 Common Work For Stage-I&Ii 25 Stress Relieving 26 Radiography 27 Removal And Refitting Of Refractory 28 Replacement Of High Pressure Valve Size Upto 2 29 Replacement Of High Pressure Line ( 1 / 2 To 4 ) ( Unit Of 01 Number Includes Two Joints ) 30 Deinsulation & Insulation With Claddingof Wall, Casing And Pipe And Other Area Of Boiler 31 Hp Valve Welding From 50 Nb Upto 100 Nbpipe 32 Hp Valve Gland Packing Replacementupto 6 33 Hp Valve Servicingincluding Gland Packing & Bonnet Seal Replacement Upto 4 34 D-Metering Of Boiler Tubeat Any Area Of Boiler For Thickness Measurement ( Minimum Survey150 Nos. / Day ) 35 Minimum Mobilization Chargeif Total Executed Job Value Less Than Rs.15000.00 36 Vertical Scaffoldingfor Approaching Roof Tube / Reheater / Secondary Sh ( Per 6 Metervertical ) For Stage I & For Approaching Furnace / Roof Tube / Pendent Reheater / Platen / Fsh & Division Wall ( Per 6 Metervertical ) For Stage Ii 37 Horizontal Scaffolding For Approaching Platen Sh / Scw / Roof Tubes / Furnace ( Per 6Meter Horizontal ) For Stage I & For Approaching Rh / Platen Sh / Final Sh / Divisional Wall / Scw / Roof Tubes / Furnace ( Per 6 Meter Horizontal ) For Stage Ii 38 Guard Tube And Guard Plateremoval, Fabrication And Fitting 39 Build Up In Eroded Tubesas Per Requirement 40 Repairing Of Skin Casing 41 Fabrication Of Bends Of Any Degree Of Any Boiler Tube 42 Fitting And Welding Of Tube Attachment Wherever Require 43 Membrane Strip Fitting & Welding 44 Fabrication And Erection Of Steel Itemsby Ms Plate / Ms Angle / Ms Channel / I Beam Etc. 45 Boiler Metal Temp Tc & Mounting Replace 46 Thermowell Replacement In Hp Line
Basic Detail
Tender No WBPDCL/BTPS/NIT/E2050/22-23
Bidding Type Tender
Location
City hooghly
State West Bengal
Key Dates
Publish Date 03 Jun 2022
Submission Date 27 Jun 2022
Open Date 29 Jun 2022
Finance
Tender Value 20.71 Lakhs
Tender Fee Ref. Documents
EMD 41500
Exemption Not Available
Document List
015a7454-f29e-4eb9-9434-f4583a03c82b.html
BOQ_748330.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jun 03, 2022
11:30 IST

Tender Published

Tender notice published.

Completed
Jun 27, 2022
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Jun 29, 2022

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

015a7454-f29e-4eb9-9434-f4583a03c82b.html

xls

BOQ_748330.xls

pdf

Tendernotice_1.pdf

TenderDetail
Loading tenders