Providing Electro Mechanical Work For Safety Equipment At Panihati Hospital Complex, Panihati Under Eastern Mechanical Division, P.H.E. Dte-2 Supply , Delivery & Storage At Site Ofhorizontal End Suctioncentrifugal Fire Pump Directly Coupled With Sui, Kolkata-West Bengal

Public Health Engineering Department-PHED has published Providing Electro Mechanical Work For Safety Equipment At Panihati Hospital Complex, Panihati Under Eastern Mechanical Division, P.H.E. Dte-2 Supply , Delivery & Storage At Site Ofhorizontal End Suctioncentrifugal Fire Pump Directly Coupled With Sui. Submission Date for this Tender is 20-06-2022. Control Cable Tenders in Kolkata West Bengal. Bidders can get complete Tender details and download the document.




Tender Notice

32516078
Providing Electro Mechanical Work For Safety Equipment At Panihati Hospital Complex, Panihati Under Eastern Mechanical Division, P.H.E. Dte-2 Supply , Delivery & Storage At Site Ofhorizontal End Suctioncentrifugal Fire Pump Directly Coupled With Sui
Open Tender
Indian
West Bengal
Kolkata
20-06-2022

Tender Details

Providing Electro Mechanical Work For Safety Equipment At Panihati Hospital Complex, Panihati Under Eastern Mechanical Division, P.H.E. Dte-2 Supply , Delivery & Storage At Site Ofhorizontal End Suctioncentrifugal Fire Pump Directly Coupled With Suitable Ratedsquirrel Cage Induction Motor ( Ie 3 ) Complete With Base Plate, Flexible Coupling, Coupling Guard, Companion Flange Foundation Bolt Etc.Having Following Speciification And As Per Technical Specification Of Nit Discharge - 2850 Lpmgenerated Head - 70 Mwch-Q-P Curve Of Pump After Testing In Test Bed Has To Be Supplied During Delivery. 3 Supply , Delivery & Storage At Site Ofhorizontal End Suctioncentrifugal Fire Pump Directly Coupled With Suitable Rateddiesel Engine Complete With Base Plate, Flexible Coupling, Coupling Guard, Companion Flange, Foundation Bolt, Start / Stop Push Button, 12 / 24 V Battery , Fuel Tank Etc.Having Following Speciification And As Per Technical Specification Of Nit Discharge - 2850 Lpmgenerated Head - 70 Mwch-Q-P Curve Of Pump After Testing In Test Bed Has To Be Supplied During Delivery. 4 Supply , Delivery & Storage At Site Ofhorizontal Centrifugal Jockey Pump Directly Coupled With Suitable Ratedsquirrel Cage Induction Motor ( Ie 3 ) Complete With Base Plate, Flexible Coupling, Coupling Guard, Companion Flange Foundation Bolt Etc.Having Following Speciification And As Per Technical Specification Of Nit Discharge - 180 Lpmgenerated Head - 70 Mwch-Q-P Curve Of Pump After Testing In Test Bed Has To Be Supplied During Delivery. 5 Supply, Delivery And Storage At Site 1.5 Hp Monoblock Pump Set ( 1 Working +Standby ) Coupled With Suitable Ratedmotor For Dewatering Of Fire Pump Houseincluding Supply Of Hose Pipe, Foot Valve, Bend, Elbow Required. 6 Supply, Delivery And Storage At Site Of Ms Black Pipe, Heavy Class ‘C’ Conforming To Is : 1239 / 3589 Including All Fittings Viz. Elbows, Tees, Flanges, E.T.C. Encentric Reducer, Concentric Enlarger, Belmouth Clamps, Etc. As Required And As Per Nit 7 200 Mm Nb ( 6.35 Mm Thick , Heavy Duty ) - For Suction And Commom Header 8 150 Mm Nb ( 5.4 Mm Thick, Heavy Duty ) For Delivery Line 9 100 Mm Nb ( 5.4 Mm Thick, Heavy Duty ) For By Pass Line 10 65 Mm Dia ( 4.5 Mm Thick, Heavy Duty ) For Suction & Delivery Of Jocky Pump 11 Supply, Delivery And Storage At Site Double Flanged Cast Iron Manually Operated Rising Spindle Sluice Valve Generally Conforming To Is:14846 Pn-1.6.And As Per Detail Given In Nit. Test Certificate To Be Produced For Each Valve. 12 200 Mm Dia 13 150 Mm Dia 14 100 Mm Dia 15 65 Mm Dia 16 Supply, Delivery And Storage At Site Of Ci Doble Flanged Single Door Swing Check N.R.Vas Per Is : 5312, Part-I, Pn-1.6 And As Per Detail Given In Nit. N.B. : Test Certificate To Be Produced For Each Valve. 17 150 Mm Dia 18 65 Mm Dia 19 Supply, Delivery And Storage At Site Bourdon Type Pressure & Compound Gauges, 100 Mm Dia Cast Aluminium Dial With , Ss Internal, Dn 15 Gi Impulse Line With Three Way Cock. 20 Pressure Guages ( 0 - 15 Kg / Cm2 ) 21 Compound Guages ( +1 To -1 Kscg ) 22 Supply Delivery And Storage Of Anti-Corrosive Tape ( 4Mm Thick ) . 23 Supply, Delivery And Storage At Site 80 Mm Diacast Iron Knetic Double Orifice Air Releasevalve As Per Relevant Is, Pn-1.6.And As Per Detail Given In Nit. :-N.B. : Test Certificate To Be Produced For Each Valve. ( At Common Delivery Header ) 24 Supply, Delivery And Storage At Site 2 Mm. Thick Crca Sheet Steel Enclosed Cubical Type Indoor Floor Mounted415 Volt Mccpanelhaving Required Feeders As Per Specification Given In Nit. 25 Installation Of All Item As Mentioned In Part-A Including Supply Of All Erection Materials, Pipe Support, Valve Support, Joint Kits, Clamps, Cable Tray Etc As Per Ie Rules To The Entire Satisfaction Of Eic. 26 Supply, Delivery, Laying And Connection Of Cable Including Supply Of Socket And Gland As Per Requirement Of Followingal. / Cu Ar. Cable In Under Ground Trench And Partly In Wall ( As Per Requirement At Site ) Properly ( Gi Pipe Protection In Concrete If Required ) And With Brick Protection On The Top Of The Cable Including Filling The Trench With Shifted Soil, Leveling Up And Restoring Surface Duly Rammed As Per Direction Of Eic. 27 1.1 Grade, 3.5 C X 185 Sq. Mm Xlpe Insulated Aluminium Armoured Power Cable ( For Sub-Station To Fire Pump Panel ) . 28 Controlcable 1.1 Kv Grade 4 C X 1.5Sq Mmarmoured Copper Control Cable ( From Phe Control Room To Fire Pump Panel ) . 29 Supply, Delivery And Storage At Site 1.1 Kv Grade3 / 31 / 2Core Xlpe Insulated Aluminium / Copper Armoured Cable As Per Technical Specification Of Nit. ( For Panelto Fire Pump Motor ) . 30 3 Core 70 Sq. Mm Al. Armoured ( From Panel To Fire Pump ) 31 Power Cable 4 C X 6 Sq. Mm Ar, Copper ( For Panelto Jocky Pump ) . 32 Power Cable 3 C X 2.5 Sq. Mm Ar, Cu Cable ( For Panelto Dewateringpump ) . 33 Supply, Delivery And Storage At Site1.1 Kv Grade Xlpe Insulatedcopper Control Cable As Per Technical Specification Of Nit. 34 2 C X 1.5 Sq. Mm Copper Cable ( For Panelto Pressure Switch ) . 35 12 C X 1.5 Sq. Mm , Ar. Copper Cable ( For Panelto Diesel Engine ) . 36 Supply, Delivery And Storage Ofpressure Switch For Auto Operation Of Fire / Jockety Pump As Per Technical Specification Of Nit 37 Supply And Delivery And Storage Of 250A Mccb, 50Ka Fixed Thermal And Megnetic Trip Unit Witrh Ss Enclosure 38 Making Internal Electrification Of Pump House Consisting Of 2Nos. Bracket, 4 Nos. Light / Fan Pts. ( 1 No.T / L, Bulk Head 2Nos. 1No. 5A Plug Pt. And 5* Rating Fan ) With Running Earthing With 14 Swg Gi Wire &Controlling Swith Of 10A B Series Dp Mcb ( HavellS / L&T ) With Outside 2 Nos. 40W Ledfittings ( Make - Approved ) Incl. Supply & Fitting Of Necessary Materials For Work & Complete Connection Inclu. Supply Of T / L Set Bulb Etc. As Per Ie Rules & Direction. 39 Supply, Delivery & Storage Of Wall Mounted Exhaust Fan 225 Mm Dia 3 Blade Make -Crompton Greves 40 Fixing Only Exhaust Fan After Making Hole In Wall And Making Good Damages And Smooth Cement Finish Etc. As Practicable As Possible And Providing Necessary Length Of Pvc Insulated Wire And Making Connection For Exhaust Of 23 Cm ( 9 ) 41 Earthing Arrangement In Compliance With Ie Rules By Gi Pipe Electrodes ( 50Mm Dia X 3Mtr. Long X 2Sets ) In Ground & Inter Conection With 50 X 6 Mm. Gi Strip With Earth Busbar To Electrodesramming Of Surface & Testing Compl. As Per Direction Including Connection Of Electrical Equipments ( Double ) To Earth Busbar To Be Done With 25X6 Mm Gi Strips Up To The Satiesfaction Of Eic. 42 Supply & Delivery Of Following Portable Fire Extinguisher As Per Technical Specification Of Nit 43 Abc Powder Type Fire Extinguishers ( Stored Pressure ) Capacity – 4 Kgs. 44 Co2 Type Fire Extinguishers ( Capacity – 3 Kgs. ) 45 Commissioning Of The Entire Installation With Mcc Panel Earthing Etc. As Per Direction And Entire Satisfaction Of Eic. 46 Part - B 47 Supply, Delivery Installation, Testing & Commissioning Of Microprocessor Based 4 Loop Fire Alarm Control Panel ( Vds & Fn 54 Approved ) Fully Networkable With Each Loop Capable Of Taking 125 Devices Display Character Alpha- Numeric Liquid Crystal Display The Panel Shall Be Soft Addressable Type. The Panel Shall Be Able To Give Pin Point Location Of All Fire / Fault Conditions. Further, The Panel Must Be Able To Automatically Switch Off Respective Control Switches When Ever Any Alarm Is Triggered. The Panel Shall Have In Built Rectifier, Provision For External & Internal Printer ( If Required ) , Loop Cards, Lcd Unit To Indicate Fire / Fault Signal With Address And Analog Output, Complete In All Respects, Having 200 Event Memory, Integral Smf Lead Acid Batteries With Sealed Cells Of 24Vcapable Of Running For A Minimum Of 8 Hours With Integral Battery Charger Complete As Required And As Per Specification. 48 Supply, Delivery, Installation Testing And Commissioning Of Pa Console Complete With Amplifier ( Capacity 300 Watts ) Microphone, 6 Hours Battery Backup And Battery Charger Ms Battery Box & Support As Per Direction Of The Engineer-In-Charge. 49 Supply, Delivery, Installation, Testing & Commissioning Of Analog Addressable Intelligent Multisensory Detector ( Vds & En 54 Approved ) As Well As Additional Heat Detector Sensor With Decentralize Intelligence, Soft Addressable Photo Thermal Type As Per Nfpa Style 7 Wiring Complete With Base As Required. 50 Supply, Delivery, Installation, Testing & Commissioning Of Analogue Addressable Intelligent Heat Detector ( Vds & En 54 Approved ) With Fixed & Rate Of Rise Temperature Function With Decentralize Intelligence, Soft Addressable Type As Per Nfpa Style 7 Wiring Complete With Base As Required. 51 Supply, Delivery, Installation, Testing & Commissioning Of Addressable Manual Call Point ( Vds & En 54 Approved ) Soft Addressable Type As Per Nfpa Style 7 Wiring Complete As Required. 52 Supply, Installation, Testing & Commissioning Of Addressable Hooter ( Sound Output Of Minimum 90 Db ) Cum Strobe ( Vds & En 54 Approved ) ( Strength Of Light 10 Cd ) Complete With Base And As Required. 53 Supply, Installation, Testing And Commissioning Of Speaker ( 6W ) Complete With Base, Mounting Box, Gland, Lugs, Etc. As Required Completing In All Respect. 54 Supply, Installation, Testing & Commissioning Of Analogue Addressable Intelligent Response Indicator Will All Accessories Complete Of Approved Band And Complete With Base As Required. 55 Supply, Installation, Testing & Commissioning Of 1Kva Offline Ups, Pure Sine Wave Out Put On Ups ( Inverter ) Mode With 15 Min Battery Backup Back Up At Rated Load. 56 Supply, Delivery And Laying Of 20 Mm Pvc Conduit.On Wall For Smoke Detector Wiring 57 Supply, Erection, Testing & Commissioning Of 2C X 1.5 Mm2 Cu Control Cable.

Key Value

Document Fees
Refer document
EMD
INR 130000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work:Providing Electro-MechanicalWork for Safety Equipment at PanihatiHospital complex, Panihati under Eastern Mechanical Division, P.H.E. Dte.
Sl. No. Item Description
1PART - A
2Supply ,Delivery & Storage at site ofHorizontal End SuctionCentrifugal Fire Pump directly coupled with suitable ratedSquirrel Cage Induction Motor (IE 3) complete with Base Plate, Flexible Coupling, Coupling Guard, Companion Flange Foundation Bolt etc.having following speciification and as per Technical Specification of NIT Discharge - 2850 LPM Generated Head - 70 MWC H-Q-P curve of Pump after testing in test bed has to be supplied during delivery.
3Supply ,Delivery & Storage at site ofHorizontal End SuctionCentrifugal Fire Pump directly coupled with suitable ratedDiesel Engine complete with Base Plate, Flexible Coupling, Coupling Guard, Companion Flange, Foundation Bolt, Start/Stop Push Button, 12/24 V Battery , Fuel Tank etc.having following speciification and as per Technical Specification of NIT Discharge - 2850 LPM Generated Head - 70 MWC H-Q-P curve of Pump after testing in test bed has to be supplied during delivery.
4Supply ,Delivery & Storage at site ofHorizontal Centrifugal Jockey Pump directly coupled with suitable ratedSquirrel Cage Induction Motor (IE 3) complete with Base Plate, Flexible Coupling, Coupling Guard, Companion Flange Foundation Bolt etc.having following speciification and as per Technical Specification of NIT Discharge - 180 LPM Generated Head - 70 MWC H-Q-P curve of Pump after testing in test bed has to be supplied during delivery.
5Supply,Delivery and Storage at site 1.5 HP Monoblock Pump set (1 Working +Standby) coupled with suitable ratedMotor for dewatering of Fire Pump Houseincluding supply of hose pipe, foot valve, bend, elbow required.
6Supply,Delivery and Storage at site of MS Black Pipe, Heavy class ‘C’ conforming to IS : 1239/3589 including all fittings viz. elbows, tees, flanges, e.t.c. Encentric Reducer, Concentric Enlarger, Belmouth clamps, etc. as required and as per NIT
7200 mm NB ( 6.35 mm thick ,Heavy Duty) - For Suction and Commom header
8150 mm NB ( 5.4 mm thick,Heavy Duty ) for Delivery line
9100 mm NB( 5.4 mm thick,Heavy Duty ) for by pass line
1065 mm dia( 4.5 mm thick,Heavy Duty ) for Suction & Delivery of Jocky pump
11Supply, delivery and storage at site Double Flanged Cast Iron Manually operated Rising Spindle Sluice Valve generally conforming to IS:14846 PN-1.6.and as per detail given in NIT. Test Certificate to be produced for each valve.
12200 mm dia
13150 mm dia
14100 mm dia
1565 mm dia
16Supply, Delivery and Storage at site of CI doble flanged Single Door Swing Check N.R.Vas per IS : 5312, Part-I, PN-1.6 and as per detail given in NIT. N.B. : Test Certificate to be produced for each valve.
17150 mm dia
1865 mm dia
19Supply, Delivery and Storage at site Bourdon type pressure & compound gauges, 100 mm dia cast Aluminium Dial with , SS internal, DN 15 GI impulse line with three way cock.
20Pressure Guages(0 - 15 kg/cm2)
21Compound Guages ( +1 to -1 KSCG)
22Supply delivery and storage of Anti-corrosive tape(4mm thick ).
23Supply, Delivery and Storage at site 80 mm diaCast Iron Knetic Double Orifice Air ReleaseValve as per relevant IS, PN-1.6.and as per detail given in NIT. :-N.B. : Test Certificate to be produced for each valve. (AT COMMON DELIVERY HEADER )
24Supply, Delivery and Storage at Site 2 mm. thick CRCA Sheet Steel Enclosed Cubical type Indoor Floor Mounted415 Volt MCCPanelhaving required Feeders as per specification given in NIT.
25Installation of all item as mentioned in part-A including supply of all erection materials, pipe support, valve support, joint kits, clamps, cable tray etc as per IE rules to the entire satisfaction of EIC.
26Supply, Delivery, Laying and Connection of Cable including supply of socket and gland as per requirement of followingAl./ Cu Ar. cable in under ground trench and partly in wall(As per requirement at site) properly(GI pipe protection in concrete if required) and with brick protection on the top of the cable including filling the trench with shifted soil, leveling up and restoring surface duly rammed as per direction of EIC.
271.1 Grade, 3.5 C X 185 sq. mm XLPE Insulated Aluminium Armoured Power Cable (For Sub-station to fire pump panel).
28Controlcable 1.1 KV Grade 4 C X 1.5sq mmArmoured Copper Control Cable(From PHE control Room to Fire Pump Panel).
29Supply, Delivery and storage at site 1.1 KV Grade3/31/2core XLPE insulated Aluminium/Copper Armoured Cable as per technical specification of NIT.(For panelto fire pump motor ).
303 Core 70 Sq. mm Al. Armoured (From Panel to Fire Pump)
31Power Cable 4 C X 6 sq. mm Ar,Copper (For Panelto Jocky pump ).
32Power cable 3 C X 2.5 sq. mm Ar,Cu cable (For panelto dewateringpump ).
33Supply, Delivery and Storage at site1.1 KV Grade XLPE insulatedCopper Control Cable as per technical specification of NIT.
342 C X 1.5 sq. mm Copper Cable (For panelto pressure switch).
3512 C X 1.5 sq. mm ,Ar. Copper Cable (For panelto Diesel Engine ).
36Supply, Delivery and Storage ofPressure Switch for Auto Operation of Fire/Jockety Pump as per Technical Specification of NIT
37Supply and delivery and storage of 250A MCCB,50KA fixed thermal and megnetic trip unit witrh SS enclosure
38Making internal electrification of pump house consisting of 2nos. Bracket, 4 nos. light /fan pts. (1 no.T/L, bulk head 2nos. 1no. 5A plug pt. and 5* rating fan) with running earthing with 14 SWG GI wire &controlling swith of 10A "B" series DP MCB (Havell"s/L&T) with outside 2 nos. 40w LEDfittings (Make - approved) incl. supply & fitting of necessary materials for work & complete connection inclu. supply of T/L set bulb etc. as per IE rules & direction.
39Supply, delivery & Storage of wall mounted exhaust fan 225 mm dia 3 blade make -crompton greves
40Fixing only exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necessary length of PVC insulated wire and making connection for exhaust of 23 cm (9")
41Earthing arrangement in compliance with IE rules by GI pipe electrodes (50mm dia X 3mtr. long X 2sets) in ground & inter conection with 50 X 6 mm. GI strip with earth busbar to electrodesramming of surface & testing compl. as per direction including connection of electrical equipments(Double) to earth busbar to be done with 25x6 mm GI strips up to the satiesfaction of EIC.
42Supply & delivery of following portable fire extinguisher as per Technical Specification of NIT
43ABC Powder Type Fire Extinguishers (Stored Pressure) Capacity – 4 Kgs.
44Co2 Type Fire Extinguishers (Capacity – 3 Kgs.)
45Commissioning of the entire installation with MCC Panel earthing etc. as per direction and entire satisfaction of EIC.
46PART - B
47Supply, delivery Installation, Testing & Commissioning of Microprocessor based 4 Loop fire alarm control panel (VDS & FN 54 approved) fully networkable with each loop capable of taking 125 devices display character alpha- numeric liquid crystal display the panel shall be soft addressable type. The panel shall be able to give pin point location of all fire/fault conditions. Further, the panel must be able to automatically switch off respective control switches when ever any alarm is triggered. The panel shall have in built rectifier, provision for external & internal printer (if required), Loop cards, LCD unit to indicate Fire/Fault Signal with address and analog output, complete in all respects, having 200 event memory, integral SMF lead acid batteries with sealed cells of 24Vcapable of running for a minimum of 8 hours with integral battery charger complete as required and as per specification.
48Supply, delivery, installation testing and commissioning of PA CONSOLE complete with amplifier (capacity 300 watts) microphone, 6 Hours battery backup and battery charger MS battery box & support as per direction of the Engineer-in-charge.
49Supply, delivery, Installation, testing & Commissioning of Analog Addressable intelligent multisensory detector (VDS & EN 54 approved) as well as additional heat detector sensor with decentralize intelligence, soft addressable Photo thermal type as per NFPA style 7 wiring complete with base as required.
50Supply, delivery, installation, Testing & Commissioning of Analogue Addressable Intelligent heat Detector (VDS & EN 54 approved) with fixed & rate of rise temperature function with decentralize intelligence, soft addressable type as per NFPA style 7 wiring complete with base as required.
51Supply, delivery, Installation, Testing & Commissioning of Addressable Manual Call Point (VDS & EN 54 approved) soft addressable type as per NFPA style 7 wiring complete as required.
52Supply, Installation, Testing & Commissioning of addressable Hooter (sound output of minimum 90 db) cum strobe (VDS & EN 54 approved) (Strength of light 10 cd) complete with base and as required.
53Supply, Installation, testing and commissioning of SPEAKER (6w) complete with base, mounting box, gland, lugs, etc. as required completing in all respect.
54Supply, Installation, Testing & Commissioning of Analogue addressable intelligent Response Indicator will all accessories complete of approved band and complete with base as required.
55Supply, Installation, Testing & Commissioning of 1KVA offline UPS, pure sine wave out put on UPS (inverter) mode with 15 min battery backup back up at rated load.
56Supply, delivery and laying of 20 mm PVC conduit.on wall for smoke detector wiring
57Supply, erection, testing & commissioning of 2C x 1.5 mm2 Cu Control Cable.
58Add: GST @ 12%