Public Health Engineering Department-PHED has published Supply, Installation, Testing And Commissioning Of Electro-Mechanical Equipments At Various Water Supply Schemes Of Jal Shakti ( Phe ) Mechanical Division South Awantipora-2 Supply, Installation, Testing And Commissioning Of 1440 Rpm Horizonta. Submission Date for this Tender is 23-06-2022. Coats and Jackets Tenders in awantipora Jammu And Kashmir. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description |
1 | 1.WSS Samboora(Adv. Cost: Rs. 30,57,700/-) |
2 | Supply, installation, testing and commissioning of 1440 rpm Horizontalpumping unit as per IS 1520 with following specification:- Pump:- 1.Type :-Horizontal split casing/Multistage Material of construction 1.Impeller:- Stainless steel 2.Shaft:-SS410 3.Pump casing:- Cast Iron The pump shall confirm to IS-1520 code MOTOR :- A)Type :- Horizontal squirrel cage Induction Type B)No of phases: 3 phase415 V+10%,50 Hz, AC supply C)Winding:-Copper wound squirrel cage D) Type of enclosure:-SPDP/TEFC E) Method of cooling:- Air cooled with fan mounted F)Method of Starting: star delta Motor Rating: 75HP (Pump 20000GPH) Note: Test certificate having the Serial No. of the Pumping Unit along with the performance curve in duplicate from the Manufacturer must be produced on delivery of the item and pumping unit is to be approved from the concerned Sub Divisional office before procuring. Detailed specifications as per cluase 5 of SBD |
3 | Supply, installation, testing and commissioning of new Horizontalpump along with a common base frame, similar to existing pump as a replacement to existing worn out pump and as per IS 1520 with following specification:- Pump:- 1.Type :-Horizontal split casing/Multistage Material of construction 1.Impeller:- Stainless steel 2.Shaft:-SS410 3.Pump casing:- Cast Iron The pump shall confirm to IS-1520 code The new pump should fit with the existing motor on the common platform Capacity of Pump 20000GPH at 90M head Note: Test certificate having the Serial No. of the Pump along with the performance curve in duplicate from the Manufacturer must be produced on delivery of the item and pump is to be approved from the concerned Sub Divisional office before procuring. Detailed specifications as per cluase 5 of SBD |
4 | Providing, fitting, testing and commissioning ofMN 140 FASD Starter, with MNX 140 contactor, MN12 relay, relay range 90-150A,, 3 pole, 3phase, 50HZ |
5 | Providing and fitting of outdoor type Electric Sub Stationby way ofS/I/T/C of 11/0.433 KVA , 3 Phase Distribution Transformer with Bimetallic Terminal connectors Energy level -2 , copper wound. Specifications conforming to IS : 1180 (Part 1) 2014 with latest amendments ertificate Rating:250KVA HT Transformer, 3 phase (Level 2). Manufactures test certicicate to be apended and rest of specification as per cluase 26 of SBD NOTE: The scope of the work shall include obtaining of necessary inspection/clearance certificate from the concerned department for all the required equipment. The testing and commissioning shall be completed only after obtaining above certificate |
6 | Providing, fitting, testing and commissioning ofvoltage stabilizeras per specifications below: Type of voltage controller: Manually operated copper wound, 3-phase, AC power supply Rest technincal specification as per cluase 45 of SBD Rating::150KVA |
7 | Providing, fitting, testing and commissioning ofMN 110 FASD Starter, with MNX 110 contactor, MN 5 relay, relay range 66-110A, 3 pole, 3phase, 50HZ |
8 | Providing, installation andtestingof manual type triple spur gearchain pulley block alonghaving following features . Gears:- The hoist shall have precision machine case Hardened alloy steel gear mounted on bearings and housed in a dust proof gear box. The lubrication of gears should be of high viscosity and temperature for longer life of gears. Load Chain:-The load chain be made of high tensile alloy steel having wear resistance and greatest mobility. The chain should be accurately collaborated, tested and have adequate in built factor of safety for safer operation. Load chain wheel:- the load chain well should be double ball bearing supported andSpecially designed, perfectly machined wheel providing correct grip of load chaintomakes the hoist most safe and reliable against any failure. The main specifications of C.P Block are given below : Make = Reputed make Capacity=3 ton (P) No. Of load chain falls = 2 or above Min. Height of lift = 6 M |
9 | 2.WSS Zantrag(Adv. Cost: Rs. 3,06,967/-) |
10 | Supply, Installation, Testing & Commissioning of Submersible Pumping Unitas per IS 8034 with following specification are as under : PUMP : Speed= 2900 Rpm Type of pump = Mixed flow. Type of fluid to be handled=Clear Water MOTOR:- Method ofstarting = Star – Delta Speed = 3000 (Sync). Frequency= 50 ± 3 % Hz Working Voltage= 380-415 ± 15% V, 03 phase Efficiency = Not less than 90% Note: Providing of test certificate & Characteristic Curve of pumping equipment is compulsory and pumping unit is to be approved from the concerned Sub Divisional office before procuring. The mainspecicifications of pumping unit are: Motor Rating: 25HP Detailed specifications as per cluase 1 SBD |
11 | Supply, Installation, Testing & Commissioning of Submersible Pumping Unitas per IS 8034 with following specification are as under : PUMP : Speed= 2900 Rpm Type of pump = Mixed flow. Type of fluid to be handled=Clear Water MOTOR:- Method ofstarting = Star – Delta Speed = 3000 (Sync). Frequency= 50 ± 3 % Hz Working Voltage= 380-415 ± 15% V, 03 phase Efficiency = Not less than 90% Note: Providing of test certificate & Characteristic Curve of pumping equipment is compulsory and pumping unit is to be approved from the concerned Sub Divisional office before procuring. The mainspecicifications of pumping unit are: Motor Rating: 10HP Detailed specifications as per cluase 1 SBD |
12 | SITC of Submersible Motor starter: MU-G 50 Fully automatic submersible motor starters. Rating = 30 HP Power Specs =3 ?, 415 + 15% V, 50 + 3 % Hz. Relay range= 30-50 A. Protection = Under voltage/ over Voltage relays with minor wiring etc |
13 | SITC of Submersible Motor starter: MU-G 20 Fully automatic submersible motor starters. Rating = 30 HP Power Specs =3 ?, 415 + 15% V, 50 + 3 % Hz. Relay range= 13-21 A. Protection = Under voltage/ over Voltage relays with minor wiring etc |
14 | Providing and fitting of 3-Core flatsubmersible copper cable conforming to IS: 694 (Part 1st) – 1964 & IS: 694 (Part 2nd) - 1964 for Submersible Pumping Unit and other electrical Equipments . The cable connections terminal shall be fitted with copper thimbles of required size. Size: 10sq.mm |
15 | Providing and installation of 200Amp capacity, 4 pole, 36 KA breaking capacity MCCB with thermal magnetic release. |
16 | 3.WSS Kandizal (Adv. Cost: Rs. 8,41,641/-) |
17 | Supply, Installation, Testing & Commissioning ofSubmersible Pumping Unitas per IS 8034 with following specification are as under: PUMP : Speed= 2900 Rpm Type of pump = Mixed flow. Type of fluid to be handled=Clear Water MOTOR:- Method ofstarting = Star – Delta Speed = 3000 (Sync). Frequency= 50 ± 3 % Hz Working Voltage= 380-415 ± 15% V, 03 phase Efficiency = Not less than 90% Note: Providing of test certificate & Characteristic Curve of pumping equipment is compulsory and pumping unit is to be approved from the concerned Sub Divisional office before procuring. The mainspecicifications of pumping unit are given below: Motor Rating: 7.5HP Detailed specifications as per cluase 1 SBD |
18 | Providing and fitting of, Ductile Iron double flanged, non-rising spindle soft seatedglandless gate/ sluice valves as per IS14846 for regulating the water supply outside the pumping units . Size: DN65 PN:1.6/16 Mnaufacturers certificate to be apended and rest of details as per cluase 12 of SBD. |
19 | Providing and fitting ofDuctile Iron double flanged, Slanted seatswing check valve( NRV) as per IS 5312. The body shall be of ductile cast iron with fully encapsulated vulcanized EPDM rubber(Approved for drinking water). Size: 65mm PN: 1.6/16 Manufacturers certificate to be apended and rest of details as per cluase 12 of SBD. |
20 | Providing/supplying and fitting ofG.I flanged Rising Main at site. The Pipe shall be hot dip Galvanized, class-C confirming to IS 1239. The job includes providing and fitting of M.S Flanges conforming to BIS 6392/1997 Table 17 (Rating PN16).s. The rising main is to be laid as per the instructions of the engineer in charge and site requirement and details as per cluase 8 of SBD Size : DN65 Class: C (Heavy) |
21 | Fabrication, providing and fitting of split type MS clamps 10 mm thick, 2 ft long and 3 inch wide for lowering and holding of pumping unit fitted. The job includes the cost of required size of nuts and bolts. Size: 80mm |
22 | Fabrication, Providing and fitting of90-120 degree bend/elbowto be fabricated out ofG.I pipeand flanged on both ends ato make it leak proof. The flanges shall be M.S Flanges conforming to BIS 6392/1997 Table 17 (Rating PN16) and welded on both sides. The job includes nuts, bolts, gaskets etc as per site requirement. Size:DN 65, Class: C |
23 | Fabrication, providing and fitting of T -junction out of 1M of pipe with 1ft each arm. The job includes all types of skilled labour,arrangement of power supply/diesel generator set etc required for the job including P/F of table 17 flanges, suitable size nuts, bolts and RI gasket in the flanged joints (Rest specification as per clause 09 of SBD). Size: 65mm, |
24 | SITC of Submersible Motor starter: MU-G 15 Fully automatic submersible motor starters. Rating = 15 HP Power Specs =3 ?, 415 + 15% V, 50 + 3 % Hz. Relay range= 9-14 A. Protection = Under voltage/ over Voltage relays with minor wiring etc |
25 | Providing and installation of 200Amp capacity, 4 pole, 36 KA breaking capacity MCCB with thermal magnetic release. |
26 | Providing and fitting of 4ft x 3ft Angle Iron board fabricated out of 50x50x6mm angle, 19 mm thick multilayered ply sheetand duly fitted with one number 0-500V Voltmeter and 0-100A Ampere meter. The board shall be provided duly painted after applying two coats of metal primer and black paint to angle and brown paint to the board |
27 | Providing and fitting of 3-Core flatsubmersible copper cable conforming to IS: 694 (Part 1st) – 1964 & IS: 694 (Part 2nd) - 1964 for Submersible Pumping Unit and other electrical Equipments . The cable connections terminal shall be fitted with copper thimbles of required size. Size: 10sq.mm |
28 | Removal of choked filter media from 5000/ 6000 GPH pressure filter vessel. The job includes all loads and lifts, disposal of choked media to dumping site outside the premises of the plant within a lead of 5 km. The vessel needs to be cleaned properly and dried before laying of fresh media. |
29 | Providing and layingof filter media of specific size and grade (preferably from sindh Nallah Ganderbal) to be laid in 5000/6000 GPH Pressure vesselduly washed, free from dust, dirt, loom and any other inorganic materialor suspension .the job includes carriage of filtermedia from Ganderbalto site including allall loads and liftsrequired on the site condition. The media is to be lad in different layers of specific size and grade from bottom to top over the filter bed plate. The bottom layer is to be laid without tilling/damaging the pressure nozzles |
30 | Providing and fitting of 12 mm dia. Fine threaded PVC nozzles auxiliary type to be fitted on filter bed plate of pressure vessel. |
31 | Providing and fitting of 29 inch. dia. rubber washers /gaskets for manhole and inspection chamber and opening of pressure filter vessel. |
32 | Providing and fitting of 3”x5/8” nuts and bolts. |
33 | P/I/T/C of horizontal monoblock pumping equipment of following parameters;a)Discharge :-6000GPH,)Head: 30 meters.c)Speed: 1440 rpmThe pump & motor should be mounted on a suitable size MS base frame . The Job also includes P/F of foundation bolts |
34 | P/I/T/C of air scavenging/blower unit of following parametersCapacity: -50 CFM,Pressure: -5PS10,Speed: -1450 RPM Motor HP- HP, |
35 | P/I/T/C of backwash pumping equipment of following parameters Discharge-16lpsHP-5, Head range 6-15mtr |
36 | Replacement of 25 mm dia. (Ball Valves-Reputed make) The job includes providing and fitting of nuts and bolts and washers with allied mechanical works. The job includes Providing, fitting of25mm dia.GI- B class 6 mtrs with necessary fittings as per requirement. |
37 | Replacement of 65 mm dia cast iron diaphram valves by way providing and fitting offresh DI gate /Butterfly valves with pressure rating of PN16 |
38 | Replacement of 65 mm Butterflyalvesof PN16 |
39 | Replacement of agitator in alum solution holding tank fabricated out of wetted parts in stainlessspeed 20-30 intermediate bearing type twin blades free standing type |
40 | Providing and fitting of Dozing pumps to be doze required quantity of alum /chlorine in the system .The capacity of the dozing units shall be 12-20 LPH capaicity withh all acessories |
41 | Providing, fabrication and fitting of welded MS wire mesh (0.50 sq. inch and 1.40mm wire dia. for Bird screening to the CGI Pressure Filter House. |
42 | Painting with synthetic enamel paint two or more coats of approved brand and bar pressure clarifier pressure filter vessel, fittings and complete piping after cleaning of dirt by kerosene oil and application of steel primer of specific grade. |
43 | 4.WSS Pahaldachan (Adv. Cost: Rs. 26,82,652/-) |
44 | Supply, Installation, Testing & Commissioning ofSubmersible Pumping Unitas per IS 8034 with following specification are as under: PUMP : Speed= 2900 Rpm Type of pump = Mixed flow. Type of fluid to be handled=Clear Water MOTOR:- Method ofstarting = Star – Delta Speed = 3000 (Sync). Frequency= 50 ± 3 % Hz Working Voltage= 380-415 ± 15% V, 03 phase Efficiency = Not less than 90% Note: Providing of test certificate & Characteristic Curve of pumping equipment is compulsory and pumping unit is to be approved from the concerned Sub Divisional office before procuring. The mainspecicifications of pumping unit are given below: Motor Rating: 12.5HP Detailed specifications as per cluase 1 SBD |
45 | Fabrication, providing, fitting and lowering ofcolumn pipe conforming to IS: 1239 of length 10 Rft into the 200/ 250/300 mm casing dia. production well up to the desired depth ; The job includes Providing and welding of flanges conforming toIS: 6392, Table-17 and PN 16 to these pipes and welding of flanges in two layers to make the flanged joint strong and leak proof. The pipe of 10 ft length is to be weld on both sides with flanges using welding rod of reputed make. The job includes all types of skilled labours, arrangement of power supply/ diesel Generator set etc required for the job including P/F of suitable size nuts bolts and R.I Gasket in the flanged joints of column pipes. The job further includes cutting of 2 no. rectangular cable slots in each flange. Size: DN 65 Class: B (Medium) |
46 | Providing/supplying and fitting ofG.I flanged Rising Main at site. The Pipe shall be hot dip Galvanized, class-C confirming to IS 1239. The job includes providing and fitting of M.S Flanges conforming to BIS 6392/1997 Table 17 (Rating PN16). The flanges shall be double welded both from inside and outside of the pipe using standard electrode of reputed make. Flanges (as per IS 6392/1997 Table:17) Thickness shall conform to IS 6392 Part 1st Table-17. The flange welding shall be carried out in double layers using reputed make electrodes to form strong welding joint. Welding Electrode DC Arc Welding using welding electrode having diameter not less than 4mm. Nuts and Bolts Nuts and Bolts (conforming to IS:1363 Part 1st) Rubber Insertion Gaskets Rubber Insertion Gaskets (conforming to IS: 638/79) to be used between flanged joints. The rising main is to be laid as per the instructions of the engineer in charge and site requirement. Size : DN80 Class: C (Heavy) |
47 | Earth work in excavation by manual means in trenches for foundation , drains ,pipes , cables (not exceeding 1.5 m in width ) and for shafts , wells , cesspits and the like not exceeding 10 sqm on plan , including dressing of sides and reaming of bottom lift upto 1.5 m , including getting out excavated earth and disposal of surplus excavated earth as directed. (All kinds of soil 01 meter from cutting edge) |
48 | Filling available excavated earth in trenches, plinth, sides of foundation etc.in layers not exceeding 20 cm in depth , consolidating each deposited layer by reaming and watering , lead upto 50 m and lift upto 1.5m. |
49 | Providing and laying of stone soling including manual compaction |
50 | Centering and shuttering including strutting , propping etc. and removal of form work for Foundation, footings, bases for columns |
51 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering . all work upto plinth level with 1: 4: 8 mix ( 1 cement , 4 coarse sand , 8 graded stone aggregate 40mm nominal size) |
52 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering . all work upto plinth level with 1: 2 : 4 mix ( 1 cement , 2 coarse sand , 4 graded stone aggregate 20mm nominal size) |
53 | Cement Plaster (in coarse sand) 12mm cement plaster mix in 1:4 (1 cement, 4 coarse sand) |
54 | Providing and fitting of 300mm in length GI reducer bend flanged on both sides, flange conforming to Table-17 (PN16) to be fitted with the column pipe/delivery manifold of submersible pumping unit to join Rising-main and column pipe/delivery manifold. The flange welding shall be carried out in double layers using reputed make electrodes from inside and outside of pipe to form strong welding joint. Size: 80mm-65mm Class: C |
55 | Fabrication, providing and fitting of split type MS clamps10 mm thick, 2 ft long and 3 inch wide for lowering and holding of pumping unit fitted. The job includes the cost of required size of nuts and bolts. Size: 80mm |
56 | Fabrication ,Providing and fitting of90-120 degree bend/elbowto be fabricated out ofG.I pipeand flanged on both ends ato make it leak proof. The flanges shall be M.S Flanges conforming to BIS 6392/1997 Table 17 (Rating PN16) and welded on both sides. The job includes nuts, bolts, gaskets etc as per site requirement. Size:DN 80 Class: C |
57 | Fabrication, providing and fitting of T -junction out of 1M of pipe with 1ft each arm. The job includes all types of skilled labour,arrangement of power supply/diesel generator set etc required for the job including P/F of table 17 flanges, suitable size nuts, bolts and RI gasket in the flanged joints (Rest specification as per clause 09 of SBD). Size: 80mm Class: C class |
58 | Providing and fitting of, Ductile Iron double flanged, non-rising spindle soft seatedglandless gate/ sluice valves as per IS14846 for regulating the water supply outside the pumping units . size 80 MMPN1.6 Manufacture test certificate to be appended. Rest ofspecification as per Cluase 12of technical anexure of SBD |
59 | Providing and fitting ofDuctile Iron double flanged, Slanted seatswing check valve( NRV) as per IS 5312. Size 80 mm PN 1.6 Manufacture test certificate to be appended. Rest ofspecification as per Cluase 13of technical anexure of SBD |
60 | Fabrication of gravel Hooper for proper feeding of gravels to the borewell andplatform to bear the load of pumping unit, column pipes etc by way of providing and fitting of Steel work welded in built up sections/framed work , including cutting , hoisting , fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. The job involves following steel details: i. In stringers , treads , landings etc of stair cases including use of chequered plate wherever required , all complete |
61 | ii. In grating , frames , guard bar , ladder , railings, brackets, gates and similar works |
62 | Providing and fitting ofM.S 4 inch hinges -6 no and M.S handle heavy -8no., Anchor bolts with nuts (M16) of 0.3 m long= 04 No. Metallic strip (350mm×50mm×3mm) = 02 No. |
63 | Fabrication of gantry mechanism/CGI Shed /angle iron sleeping bedby way of providing Structural steel in built up sections , trusses and framed work, including cutting , hoisting , fixing in position and applying a priming coat of approved steel primer all complete welded |
64 | Providing, installation andtestingof manual type triple spur gearchain pulley block along with monorail gearedtravelling trolleyhaving following features : Make= Reputed make Capacity =2ton No. Of load chain falls = 2 or above Min. Height of lift = 6 M Manufacture test certificate to be appended. Rest ofspecification as per Cluase 24of technical anexure of SBD |
65 | S/I/T & C of Portable Handheld Clamp-On Ultrasonic Flow meter complete with all accessories with following specifications as under : Accuracy: ±1% of velocity reading or ±10mm/s, whichever is bigger. Response Time: 0-999 seconds, user-configurable Velocity:(-10m/s ~ +10m/s), bi-directional For Pipe Size: ND50mm ~ ND600mm Pipe Material: All metals, most plastics, lined pipe Display: 4x16 letters English letters, 240 x 200 pixel backlit LCD graphic display. Digital Interface: OCT digital output, can be configured as frequency or pulse output . Windows PC software for data download and real-time data acquisition Transducers: Standard medium size transducer for V-method type (magnetic/Non-Magnetic with clamp-on fixture).For Pipe size: (DN50 ~ DN600mm). Housing Material: Protective case suitable for normal and harsh environment. Accoustic Coupler:Silicone free-grease/Silicone grease Rest ofTechnical specification as per Cluase 66 of technical anexure of SBD |
66 | Fabrication, Providing and fitting of 20 HP Modularmotor control panel of appropriate size fabricated out of 14 SWG sheet having required openings/vents and protection Class : IP-55 & fitted with accessories: Rest specification as per SBD clause 43D |
67 | Providing, fitting, testing and commissioning ofvoltage stabilizeras per specifications below: Type of voltage controller: Manually operated copper wound, 3-phase, AC power supply multi step. Type of Regulator: Double plate type with electrolytic copper contacts. Input voltage : 250-400 volts.(3 phase) Output voltage : 400 ±10% volts. Frequency : 50±3 C/S. Windings : Electrolytic grade copper of adequate section, vacuum impregnated and Oven-dried. Insulation : Fiber glass insulations to tested parameters. Cooling: Naturally, Oil cooled Temp. Rise (Max) : 30°C above ambient Mounting : On Uni-directional wheels. Correction rate : 30 volts per step Wave form distortion: virtually nil Duty cycle : 100% continuous. Enclosure : MS sheet enclosure in pressed CGR Sheet powder coated with radiators. Core laminates: High grade, low eddy loss, grain oriented silicon steel laminations. Load: Three phase induction motor load. Load Amperes (continuous) Rating::50KVA Rest ofTechnical specification as per Cluase 45 of technical anexure of SBD |
68 | Providing and fitting of 3-Core flatsubmersible copper cable conforming to IS: 694 (Part 1st) – 1964 & IS: 694 (Part 2nd) - 1964 for Submersible Pumping Unit and other electrical Equipments . The cable connections terminal shall be fitted with copper thimbles of required size. Size: 10sq.mm |
69 | Providing and Fitting of 2/3 /3.5/Core, XLPE, 1.1KV and 11KV grade Armoured Aluminium Cable conforming to IS: 7098 part 1st as service line from the HT transformer to control panel including necessary thimbling, crimping, taping etc. NOTE:- The cable terminal ends for connection to switchgear at various requisite points shall be Al. Thimbles of dowel’s make and of appropriate size and connected by hydraulic crimp tool only. Rest Specifications as per clause 71 of SBD i) 50 sqmm , 3.5core, LT ,1.1 KV |
70 | ii) 10sqmm, 2 core, LT , 1.1 KV |
71 | P/I of earthing station for substation, LT panel, DG set and stabilizer comprising of company fabricated earthing electrode as per IS: 3043. The job includes Auguring of bore of required dia/depth for installation of electrode along with backfill compound mixed with soil and all other items required thereof for achieving the best result. The job includes connecting of electric gadgets through GI strip as per relevant standards. Safe earthing electrode size:80 mm dia , Length :2000 mm Back fill compound :30 kg |
72 | Supply, installation of 6 kg co2 type fire extinguisher manufactured as per IS:15683 OF 2006 with IS mark and comply with DGMS(Approval)Rest ofTechnical specification as per Cluase 50of technical anexure of SBD |
73 | IlIllumination of Premises: Providing and erection of 9 Mtr long Hot Dip Galvanized octagonal pole (single Section) with bottom 150mm, top 75mm wide, thickness 3mm with 70 Microns Zinc coating having inside arrangement for providing of power connection along with following items. 1) 3 Way Terminal Connector 20 Amp. 2) 3 No MCB 8 Amp. Rest ofTechnical specification as per Cluase 51of technical anexure of SBD |
74 | Providing, installation, testing and commissioning of area lighting 120 Watt LED (Street Light Type) on top of octagonal pole . Rest ofTechnical specification as per Cluase 52of technical anexure of SBD |
75 | Providing, Installation and testing of 2KVA fully automatic voltage stabilizer with input voltage 70-240 V and output 220 V. The stabilizer shall be installed and connected to the electric circuit as per location provided by site incharge. |
76 | Supply, installation, Testing & commissioning of 1000VA Full Sine wave power inverter (Make: Microtek/Luminous) including Providing / Installation of 12V, 180AH Tubular inverter Battery with trolley and cover. (Make: Amaron /Exide) with 2-core 6mm2 Cu wiring as per site requirement along with other accessories like SS-Combine (02 No’s), 3-pin plugs etc of reputed make for proper fitment and installation of the item. |
77 | Providing, laying & fixing with adhesive/bonding material of insulation rubber mats on the floor of the pump house, covering area around electro-mechanical machinery for safeguarding the life & limb of the workmen due to possible leakage of current & short circuit. The floor surface shall be made good & shall be free from dust, grease, foreign material & moisture free. The mats shall be as per IS 15652:2006 & shall have the following specifications: - Composition: Rubber (synthetic mats for electrical purpose) Thickness: - 2.5mm Size: - 1M wide. The rubber mats shall be accepted with manufacturers test certificate. |
78 | TOOL KIT For Maintenance: - The Tool Kit for maintenance shall comprise of the following and all the items asperTechnical specification as per Cluase 56of technical anexure of SBD |
79 | Providing and fitting of 19 mm thick multilayered ply sheet of size 6 x 3 feet , 2 nos including cutting , fixingall complete including painting of the play sheet by one coat of primer and two coats of enamel paint |
80 | Providing of good quality convenience and utility items specicifications are as per clause-57 ofTechnical annexure of SBD. |
81 | Providing of solar/ electrical lantern chargeable on both solar & electrical 220v supply. |
82 | Providing of bamboo ladders 18 feet long along with 15 feet long Link rods and HT Glove pair (01 No each) |
83 | Providing of 1 KW heat convector for operators for winter season. |
84 | Providing and fitting of 01 No. LED (scroll type) sign board fabricated out of stainless steel and metal showing the names of water supply scheme and the Department. Size:6’×1’6”= 9 sft |
85 | Providing and fitting of 01 No. angle iron/sheet metal board duly painted showing various specifications of the mechanical and electrical equipments installed at site. Size: 4’×6’ out MS ANGLE OF 40X 40X 5of 36 rft and MS sheet of 1 mmthicktotal weight of50.16 kgs |
86 | Carriage of sand , stone aggregate by mechanical transportincluding loading , unloadingand stacking (average distance-5km) |
87 | Carriage of soling stone by mechanical transportincluding loading , unloadingand stacking (average distance-5km) |
88 | Carriage of cement/steel/CGI sheet/GI pipes below 100mm dia and other heavy materials by mechanicaltransportincluding loading , unloadingand stacking (average distance -25Km) |
89 | SERVICING OF 25KVA DG SET AVAILABLE AT W.S.S PALDACHAN OLD a. Shifting of available DG set installed at W.S.S Paldchan (Old) to Paldachan (New) in a private load carrier & placing it preciselyover the concrete bedthrough mechanical means without causing any damage to DG set or to concrete bed. a) Complete M oil change of the engine after flushing the chamber with engine flush oil (500ml) to remove all un-dissolved impurities & then providing & filling of 08 Litres of fresh M oil of Servo/Shell/ Tata BP. The job also includes providing & filling of required quantity of diesel additive to diesel tank. b)Providing & fitting of air filter element one set (Inner & outer) along with nuts & bolts, fuel filter element 02 No, & M.oil filter element 02 No & Air Hoseby way of first removing the older/damaged one and replacing it with new one. c)Engine tuning by way of dismantling the engine tappet cover, fuel injectors and washing the injector nozzles using suitable agent. This includes testing & adjustments of injection nozzle for leaks & opening pressure. The job also includesprovidingthe tappet gasket coverand fitting it by means of high tempt resistant gasket maker and refitting the same. d) Providing of 50 ltrs of HSD for initial testing of DG set at site. |
90 | Creation of pope mounted , outdoor type Electric Sub Stationby way ofS/I/T/C of 11/0.433 KVA , 3 Phase Distribution Transformer with Bimetallic Terminal connectors Energy level -2 Aluminum wound Specifications conforming to IS : 1180 (Part 1) 2014 with latest amendments ertificate Rating:63KVA HT Transformer, 3 phase (Level 2). Manufactures test certicicate to be apended and rest of specification as per cluase 26 of SBD NOTE: The scope of the work shall include obtaining of necessary inspection/clearance certificate from the concerned department for all the required equipment. The testing and commissioning shall be completed only after obtaining above certificate |
91 | Providing and fittingG.I Channel /Angle/ Flat of sizes including clamps |
92 | Supply, Installation, Testing and commissioning of Polymeric Gang operated Air break switch, outdoor type, triple pole, suitable for vertical installation, single break provided with locking arrangement at both ON and OFF position consisting ofHT post double insulator, copper or copper alloy high pressure heavy contact assembly, rod with bearings , operating handle and 2 length of 32mm dia. GI pipe conforming to IS 1818 1961, 06 No. of insulators, rated voltage 11KV 200A complete as per IS specs. |
93 | Supply, Installation, Testing and commissioning of 11KVpolymer fuses SetHorn Gap3-phase 200 Asuitable for vertical installation . |
94 | Supply, Installation, Testing and commissioning ofGapless Surgearrestor station class, 10KA, 9KV, LA With polymer housing , Station Type . |
95 | Supply and fitting of 11 KV polymeric composite pin insulator 12 KV, 5KN, Lighting impulse 75KV Positive, and 80 KV Negative , creepagedistance 320 mm |
96 | Supply, installation, errection of9 mtrs long ST- 410 (sp-33) . The job further includes drilling of holes for installation of various accessories .wherever required. The job further includes GI wire earthing of pole as per REC standard. |
97 | P/F of Galvanized nuts, bolts of various sizes as per site requirement. |
98 | P/F Danger Plate with clamps |
99 | Providing and fixing G.I Barbed wire for anti climbing |
100 | Providing and fixing of anti climbing devices with clamps |
101 | Providing and fitting of Galvanized stay set with 50 X 8 mm Stay Clamp, Guy insulator (2no.), Anchor plate (200X200X6mm), nuts and bolts, 2 N0- turn buckle, 1.8 m long, 16 mm diameter solid G.I stay rod & 7/3.15 mm dia. G.I stranded wire complete. |
102 | Painting of poles Red oxide |
103 | Painting of poles Aluminum paint |
104 | Providing and fitting of ACSR as per IS 398 (part-2) 1996 for 50 sq.mmACSR (Galvanised steel reinforced) for fitment of various accessories |
105 | Supply, Installation and Testing of 35 Sq mm XLPE Aluminum H.Tcable (ABC type ) of 11 KV grade with following specs. Size (cross sectional area in sq mm) = 3×35 with reinforced wire Phases:Red, Yellow, Blue |
106 | Providing and fitting of Anchoring clampscomprising clamp body , plastic wedge, steel bill bracket , straps and buckles or nuts and bolts required for holding of 3 – Core , 35 Sq. mm H.T AB Cable. |
107 | P/F of 11 KV cable termination kit for connecting 35 Sq mm XLPE cable (ABC type) with the existing HT line near tapping point and HT transformer. |
108 | Providing and fitting of LT Distribution box for HT transformer with MCCB For incomer and SFU for out going circuits . Capacity of transformer: 63KVA |
109 | 5.WSS Nazbal Sail (Adv. Cost: Rs. 5,31,838/-) |
110 | Supply, Installation, Testing & Commissioning of Submersible Pumping Unitas per IS 8034 with following specification are as under : PUMP : Efficiency = Not less than 50% Speed= 2900 Rpm Type of pump = Mixed flow. Type of fluid to be handled=Clear Water Complete Specification as per Clause - "1" of SBD. Motor Capacity:30HP |
111 | Providing and fitting of 3-Core flatsubmersible copper cable conforming to IS: 694 (Part 1st) – 1964 & IS: 694 (Part 2nd) - 1964 for Submersible Pumping Unit and other electrical Equipments. The cable connections terminal shall be fitted with copper thimbles of required size. Size: 16sq.mm |
112 | Providing, fitting, testing and commissioning ofvoltage stabilizeras per specifications below: Type of voltage controller: Manually operated copper wound, 3-phase, AC power supply multi step. Type of Regulator: Double plate type with electrolytic copper contacts. Input voltage : 250-400 volts.(3 phase) Output voltage : 400 ±10% volts. Complete Specification as per Clause - 44 Of SBD. Rating:50KVA |
113 | Fabrication of gantry mechanism/CGI Shed /angle iron sleeping bedby way of providing Structural steel in built up sections , trusses and framed work, including cutting , hoisting , fixing in position and applying a priming coat of approved steel primer all complete welded |
114 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering . all work upto plinth level with 1: 2 : 4 mix (1 cement, 2 coarse sand, 4 graded stone aggregate 20mm nominal size) |
115 | Providing, installation andtestingof manual type triple spur gearchain pulley block along with monorail gearedtravelling trolleyhaving following features. Gears:- The hoist shall have precision machine case Hardened alloy steel gear mounted on bearings and housed in a dust proof gear box. The lubrication of gears should be of high viscosity and temperature for longer life of gears. Load Chain:-The load chain be made of high tensile alloy steel having wear resistance and greatest mobility. The chain should be accurately collaborated, tested and have adequate in built factor of safety for safer operation. Load chain wheel:- the load chain well should be double ball bearing supported andSpecially designed, perfectly machined wheel providing correct grip of load chaintomakes the hoist most safe and reliable against any failure. The main specifications of C.P Block are given below : Make = Reputed make Capacity=3ton No. Of load chain falls = 2 or above Min. Height of lift = 6 M |
116 | Carriage of sand, stone aggregate by mechanical transportincluding loading, unloadingand stacking (average distance-5km) |
117 | Carriage of cement/steel/CGI sheet/GI pipes below 100mm dia and other heavy materials by mechanicaltransportincluding loading, unloadingand stacking (average distance -25Km) |
118 | 6.WSS Chersoo Spring (Adv. Cost: Rs. 9,89,146/-) |
119 | Supply, Installation, Testing & Commissioning of Submersible Pumping Unitas per IS 8034 with following specification are as under : PUMP : Efficiency = Not less than 50% Speed= 2900 Rpm Type of pump = Mixed flow. Type of fluid to be handled=Clear Water MATERIAL OF CONSTRUCTION: Impeller= Stainless Steel Complete Specification as per Cluase - "1" of SBD. Motor Capacity:20 HP or suitable for above parameters |
120 | Providing and fitting of, Ductile Iron double flanged, non-rising spindle soft seatedglandless gate/ sluice valves as per IS14846 for regulating the water supply outside the pumping units . The body and bonnent of the valve shall be of ductileiron, wedge with fully vulcanized EPDM rubber(Approved for drinking water) and NBR seal. The Gate/Sluice valve shall be compatible for buried applications and shall be safe to install in both horizontal and vertical positions It shall have electrostatic epoxy coating(approved for drinking water) both inside and outside of the valve. The valve shall be supplied along with hand wheel. Cost on account of Nuts, bolts, gaskets, etc required for the job is included in the scope of work. The job includes providing and fitting of 02 nos. M.S flanges perfectly adaptable to the inbuilt flanges of the valve which shall be fitted with rising main of the pumping unit at appropriate spots as per site requirement. i. Size: DN 80 PN:1.6/16 |
121 | ii.Size: DN 100 PN:1.6/16 |
122 | Providing and fitting ofDuctile Iron double flanged, Slanted seatswing check valve( NRV) as per IS 5312. The body shall be of ductile cast iron with fully encapsulated vulcanized EPDM rubber(Approved for drinking water). The valve shall be compatible for buried applications and shall be safe to install in both horizontal and vertical positions. It shall have electrostatic epoxy coating (approved for drinking water) both inside and outside of the valve. Cost on account of Nuts, bolts, gaskets, etc required for the job is included in the scope of work. The job includes providing and fitting of 02 nos. M.S flanges perfectly adaptable to the inbuilt flanges of the valve which shall be fitted with Rising main of the pumping unit at appropriate spots as per site requirement. i. Size: DN 100 PN:1.6/16 |
123 | ii. Size: DN 80PN:1.6/16 |
124 | Providing, fitting, testing and commissioning of50mm diameter ARV (Air Release valve ) as per IS 14845 to be fitted toG.Irising Main. The ARV Shall have the following specifications: i. Valve type -single chamber, single orifice. ii. End connection-flanged ends to IS 1538 iii. Working temperature- 20?C to 45?C iv. Test pressure - body / seat 2.5 x PN v. Sealing ring -EPDM vi. Construction-ductile iron with stainless steelfloats vii. Coating -epoxy with corrosion resistance Besides the above works, The job also cost on account of P/F R.I gasket, nuts and bolts required for installation of ARV and arrangement of gas cutter/ welding set at site. The job also includes cutting of 50 mm dia hole in rising main and P/F of50mm dia.M.S Pipe one feet long with one end flanged perfectly adaptable to Flange of ARV and other end welded to 50 mm dia hole of rising main. size = DN 50 , PN 1.6/16 |
125 | Providing , fitting , testing and commissioning of FASDSubmersible pump controller having following specification capacity of stater = 30 HP Rating= As per requirement , 415, 3 Phase Power Specs =3 ?, 415 + 15% V, 50 + 3 % Hz. Relay range= 30 - 50 A. Coil Voltage=380 v Rated insulation voltage = 690V Terminal capacity = 50 Sq. mm with lug Conformity to standard=IS/IES 60947-4-1 No of full starts = 30 Per Hour Back up Protection = Type 2 with HN Fuse Protections = Thermal Overload with pre-alarm, Short Circuit, PhaseLoss,current/ voltage Unbalance, Phase reversal, Under Current, Prolong statrting, Locked Rotor & Earth fault. |
126 | Creation of pope mounted , outdoor type Electric Sub Stationby way ofS/I/T/C of 11/0.433 KVA , 3 Phase Distribution Transformer with Bimetallic Terminal connectors Energy level -2 Aluminum wound Specifications conforming to IS : 1180 (Part 1) 2014 with latest amendments Type of cooling:ONAN. Complete Specifications as per Cluase - "26" of SBD Rating: 100KVA HT Transformer, 3 phase (Level 2). |
127 | Providing and fittingG.I Channel /Angle/ Flat of sizes including clamps |
128 | Supply, Installation, Testing and commissioning of Polymeric Gang operated Air break switch, outdoor type, triple pole, suitable for vertical installation, single break provided with locking arrangement at both ON and OFF position consisting ofHT post double insulator, copper or copper alloy high pressure heavy contact assembly, rod with bearings , operating handle and 2 length of 32mm dia. GI pipe conforming to IS 1818 1961, 06 No. of insulators, rated voltage 11KV 200A complete as per IS specs. |
129 | Supply, Installation, Testing and commissioning of 11KVpolymer fuses SetHorn Gap3-phase 200 Asuitable for vertical installation . |
130 | Supply, Installation, Testing and commissioning ofGapless Surgearrestor station class, 10KA, 9KV, LA With polymer housing , Station Type . |
131 | Supply and fitting of 11 KV polymeric composite pin insulator 12 KV, 5KN, Lighting impulse 75KV Positive, and 80 KV Negative , creepagedistance 320 mm |
132 | P/F of Galvanized nuts, bolts of various sizes as per site requirement. |
133 | P/F Danger Plate with clamps |
134 | Painting of poles Red oxide |
135 | Painting of poles Aluminum paint |
136 | Providing and fitting of ACSR as per IS 398 (part-2) 1996 for 50 sq.mmACSR (Galvanised steel reinforced) for fitment of various accessories |
137 | Supply, Installation and Testing of 35 Sq mm XLPE Aluminum H.Tcable (ABC type ) of 11 KV grade with following specs. Size (cross sectional area in sq mm)=3×35 with reinforced wire Phases:Red, Yellow, Blue |
138 | Providing and fitting of Anchoring clampscomprising clamp body, plastic wedge, steel bill bracket, straps and buckles or nuts and bolts required for holding of 3 – Core, 35 Sq. mm H.T AB Cable. |
139 | P/F of 11 KV cable termination kit for connecting 35 Sq mm XLPE cable (ABC type) with the existing HT line near tapping point andHT transformer. |
140 | Providing and fitting of 3-Core flatsubmersible copper cable conforming to IS: 694 (Part 1st) – 1964 & IS: 694 (Part 2nd) - 1964 for Submersible Pumping Unit and other electrical Equipments . The cable connections terminal shall be fitted with copper thimbles of required size. Size: 16sq.mm |
141 | P/I of earthing station for substation, LT panel, DG set and stabilizer comprising of company fabricated earthing electrode as per IS: 3043. The job includes Auguring of bore of required dia/depth for installation of electrode along with backfill compound mixed with soil and all other items required thereof for achieving the best result. The job includes connecting of electric gadgets through GI strip as per relevant standards. Safe earthing electrode size:80 mm dia, Length :2000 mm Back fill compound :30 kg |
142 | Earth work in excavation by manual means in trenches for foundation, drains, pipes, cables (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and reaming of bottom lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed. (All kinds of soil 01 meter from cutting edge) |
143 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. all work upto plinth level with 1: 2 : 4 mix (1 cement, 2 coarse sand, 4 graded stone aggregate 20mm nominal size) |
144 | Illumination of Premises: Providing and erection of 9 Mtr long Hot Dip Galvanized octagonal pole (single Section) with bottom 150mm, top 75mm wide, thickness 3mm with 70 Microns Zinc coating having inside arrangement for providing of power connection along with following items. 1) 3 Way Terminal Connector 20 Amp. 2) 3 No MCB 8 Amp. The job includes fabrication, providing and fitting of three arm GI structure at the top having 120° angle between arms and each arm having 15° inclination with respect to horizontal plane. Each arm should be of 2’ length and size and shape appropriate as per requirement of the luminary. The job also includes providing and fitting of required length of flexible multi strand 2 mm copper wire from each terminal connector to each holding arm. The pole is to be mounted oncement concrate block by way of Providing and fixiong of 04 No anchor bolts of required size not less than 1 feetin length. The complete job includes earthing in GI Electrode as per relevant IS Code. |
145 | Providing, installation, testing and commissioning of area lighting 120 Watt LED (Street Light Type) on top of octagonal pole vide item No.36 Having following specs: Input: 90-240 V 50 Hz Power Factor: >0.9 Colour Temperature: 4K - 6.5K Beam Angle: 120° - 170° Lumens: >12000 Operating Temperature: -20°C to 60°C The LED is pressure die cast aluminum housing with power coated finish and having Ingress Protection up to IP-68. The LED is to be properly fitted on the arm of the pole and connected to the copper wire as directed. |
146 | Providing and Fitting of 3 /3.5/2-Core, XLPE Armoured Aluminium Cable conforming to IS: 7089 part 1st as service line from the HT transformer to control panel including necessary thimbling, crimping, taping etc. NOTE:- The cable terminal ends for connection to switchgear at various requisite points shall be Al. Thimbles of dowel’s make and of appropriate size and connected by hydraulic crimp tool only. 10sqmm, 2 core, LT , 1.1 KV |
147 | P/Fof lighting points in 1.5 sq.mm multi strand PVC wire as conductor to be laid / carried in PVC Channel / conduit as per site requirement duly fiited with approperiate fasteners. the job includes providing and fittingof all the PVC bends , connectors etc and5 Amp. Switch fitted on common plate flushed with wallfor beter look andbutton / Angle Holders to be fittedon with LED blubs(energy saver)inside the pump house. |
148 | P/F of heating points in 2.5 Sq. mm multi stranded PVC conductor to be carried in PVC channel/conduit as per site requirement duly fiited with approperiate fasteners . the job includes providing and fitting ofall the PVCbends , connectors 16 Amp. Switch socket combine to be fiited flushed with wall |
149 | P/F of distribution board of SP & N (regal gray ) with 1 no. incoming and outgoing 16 way , fitted with MCB“C” Series6A- 12Nos. and 16 Amp- 4nos for heating points and 36 AMCB For mains. The job includes the cost of 4 Sq. mm multi stranded PVC conductor to be laid as service line for lighting system. |
150 | Providing and fitting of 18"" sweep seiling fan of standard make including the cost of all cables, connections, controlsystem along with the speed regulator with control switches for the power supply |
151 | 7.WSS Beighpora Tokina (Adv. Cost: Rs. 14,74,631/-) |
152 | Supply, Installation, Testing & Commissioning of 12.5HP, non clogPumping Unit as per IS 5600 at Raw Water Stage. PUMP: - Type of pump :non –clogOpen wellSubmersible Vertical Pump Solid Handling Capacity: 20mm (Minimum) Solid Handling Capacity: 20mm (Minimum) Quality of water:Raw water o be handled MOTOR: - Type : Squirrel Cage 3-Phase Induction Motor Sealing: Dual mech. seal. Provided with thermal and overload protection Dual Mechanical Seals (01 No) and Bearings (02 No) for the pumping unit must be provided as spare parts for preventive maintenance by the firm. for each pumping unit Note: Test certificate having the Serial No. of the Pumping Unit along with the performance curve in duplicate from the Manufacturer must be produced on delivery of the item. Manufacturers certificate to be apended and Detailed specifications as per cluase 2 ofSBD |
153 | Providing and fitting of, Ductile Iron double flanged, non-rising spindle soft seatedglandless gate/ sluice valves as per IS14846 for regulating the water supply outside the pumping units .Size: DN80PN:1.6/16Manufacture test certificate to be appended. Rest ofspecification as per Cluase 12of technical anexure of SBD |
154 | Providing and fitting ofDuctile Iron double flanged, Slanted seatswing check valve (NRV) as per IS 5312. The body shall be of ductile cast iron with fully encapsulated vulcanized EPDM rubber(Approved for drinking water). Size: 80mm PN: 1.6/16 Manufacturers certificate to be apended and detailed specification as per cluase 13 of SBD |
155 | Fabrication, Providing and fitting of20 HP Modularmotor control panel of appropriate size fabricated out of 14 SWG sheet having required openings/vents and protection Class Detailedspecification as percluase 43 d of SBD |
156 | Creation of pole mounted , outdoor type Electric Sub Stationby way ofS/I/T/C of 11/0.433 KVA , 3 Phase Distribution Transformer with Bimetallic Terminal connectors Energy level -2 Aluminum wound Specifications conforming to IS : 1180 (Part 1) 2014 with latest amendments Type of cooling:ONAN. Rating: 63 KVA HT Transformer, 3 phase (Level 2). Manufacture test certificate to be appended. Rest ofspecification as per Cluase 26of technical anexure of SBD |
157 | Supply, installation, errection of9 mtrs long ST- 410 (sp-33) . The job further includes drilling of holes for installation of various accessories .wherever required. The job further includes GI wire earthing of pole as per REC standard. |
158 | Supply, Installation, Testing and commissioning of Polymeric Gang operated Air break switch, outdoor type, triple pole, suitable for vertical installation, single break provided with locking arrangement at both ON and OFF position consisting ofHT post double insulator, copper or copper alloy high pressure heavy contact assembly, rod with bearings , operating handle and 2 length of 32mm dia. GI pipe conforming to IS 1818 1961, 06 No. of insulators, rated voltage 11KV 200A complete as per IS specs. |
159 | Supply, Installation, Testing and commissioning of 11KVpolymer fuses Set Horn Gap3-phase 200 Asuitable for vertical installation . |
160 | Supply, Installation, Testing and commissioning ofGapless Surgearrestor station class, 10KA, 9KV, LA With polymer housing , Station Type . |
161 | Supply and fitting of 11 KV polymeric composite pin insulator 12 KV, 5KN, Lighting impulse 75KV Positive, and 80 KV Negative , creepagedistance 320 mm |
162 | Providing and fittingG.I Channel /Angle/ Flat of sizes including clamps |
163 | P/F of Galvanized nuts, bolts of various sizes as per site requirement. |
164 | Removal of choked filter media from 5000/ 6000 GPH pressure filter vessel. The job includes all loads and lifts, disposal of choked media to dumping site outside the premises of the plant within a lead of 5 km. The vessel needs to be cleaned properly and dried before laying of fresh media. |
165 | Providing and layingof filter media of specific size and grade (preferably from sindh Nallah Ganderbal) to be laid in 5000/6000 GPH Pressure vessel duly washed, free from dust ,dirt ,loom and any other inorganic materialor suspension .the job includes carriage of filtermedia from Ganderbalto site including allall loads and liftsrequired on the site condition. The media is to be lad in different layers of specific size and grade from bottom to top over the filter bed plate. The bottom layer is to be laid without tilling/damaging the pressure nozzles |
166 | Providing and fitting of 12 mm dia. Fine threaded PVC nozzles auxiliary type to be fitted on filter bed plate of pressure vessel. |
167 | Providing and fitting of 29 inch. dia. rubber washers /gaskets for manhole and inspection chamber and opening of pressure filter vessel. |
168 | Providing and fitting of 3”x5/8” nuts and bolts. |
169 | Painting with synthetic enamel paint two or more coats of approved brand and bor pressure clarifier pressure filter vessel, fittings and complete piping after cleaning of dirt by kerosene oil and application of steel primer of specific grade. |
170 | P/I/T/C of horizontal monoblock pumping equipment of following parameters; a) Discharge :-6000GPH, b) Head: 30 meters. c) Speed: 1440 rpmThe pump & motor should be mounted on a suitable size MS base frame . The Job also includes P/F of foundation bolts |
171 | P/I/T/C of backwash pumping equipment of following parametersDischarge-16lpsHP-5,Head range 6-15mtr |
172 | P/I/T/C of air scavenging/blower unit of following parametersCapacity: -50 CFM,Pressure: -5PS10,Speed: -1450 RPMMotor as per requirment |
173 | Providing, fabrication and fitting of welded MS wire mesh (0.50 sq. inch and 1.40mm wire dia. for Bird screening to the CGI Pressure Filter House. |
174 | Replacement of 25 mm dia. -03 no’s (Ball Valves-Reputed make) The job includes providing and fitting of nuts and bolts and washers with allied mechanical works. The job includes Providing, fitting of25mm dia.GI-6 mtrs with necessary fittings as per requirement. |
175 | Replacement of 80 mm dia cast iron diaphram valves by DI Gate valve |
176 | Replacement of 65 mm Butterfly valvesof PN16 |
177 | Replacement of agitator in alum solution holding tank fabricated out of wetted parts in stainlessspeed 20-30 intermediate bearing type twin blades free standing type |
178 | Providing and fitting of Dozing pumps to be doze required quantity of alum /chlorine in the system .The capacity of the dozing units shall be 12-20 LPH capaicity withh all acessories |
179 | Providing and fitting of pressure gauges with adopters to replace damaged ones these pressure gauges should be in the range of 0-50 kgf/cm/sg and be reputed make. |
180 | Providing and fitting65 mm dia MS flanged pipe to be installed at inlet/utlet of preset ling filter vessele of setlled water puping unit (class C) |
181 | Providing, installation, testing and commissioning of area lighting 120 Watt LED (Street Light Type) insidevide item No.36 Having following specs: Input: 90-240 V 50 Hz Power Factor: >0.9 Colour Temperature: 4K - 6.5K Beam Angle: 120° - 170° Lumens: >12000 Operating Temperature: -20°C to 60°C Rest ofTechnical specification as per Cluase 51of technical anexure of SBD |
182 | Providing, Installation and testing of 2KVA fully automatic voltage stabilizer with input voltage 70-240 V and output 220 V. The stabilizer shall be installed and connected to the electric circuit as per location provided by site incharge. |
183 | Providing and installation of Junction Box with DP 32 A MCB to serve as Main switch for LED Lighting. The job includes making of electric connection to the circuit. |
184 | Fabrication of gantry mechanism by way of providing Structural steel in built up sections , trusses and framed work, including cutting , hoisting , fixing in position and applying a priming coat of approved steel primer all complete welded |
185 | Providing, installation andtestingof manual type triple spur gearchain pulley block along with monorail gearedtravelling trolleyhaving following features: Make = Reputed make Capacity=2 ton (P) No. Of load chain falls = 2 or above Min. Height of lift = 6 M Detailed specification as per cluase 24 of SBD |
186 | Supply, installation, errection of9 mtrs long ST- 410 (sp-33) . The job further includes drilling of holes for installation of various accessories .wherever required. The job further includes GI wire earthing of pole as per REC standard. |
187 | Supply, Installation, Testing and commissioning of Polymeric Gang operated Air break switch, outdoor type, triple pole, suitable for vertical installation, single break provided with locking arrangement at both ON and OFF position consisting ofHT post double insulator, copper or copper alloy high pressure heavy contact assembly, rod with bearings , operating handle and 2 length of 32mm dia. GI pipe conforming to IS 1818 1961, 06 No. of insulators, rated voltage 11KV 200A complete as per IS specs. |
188 | Supply, Installation, Testing and commissioning of 11KVpolymer fuses SetHorn Gap3-phase 200 Asuitable for vertical installation . |
189 | Supply, Installation, Testing and commissioning ofGapless Surgearrestor station class, 10KA, 9KV, LA With polymer housing , Station Type . |
190 | Providing and Fitting of 3 /3.5/2-Core, XLPE Armoured Aluminium Cable conforming to IS: 7089 part 1st as service line from the HT transformer to control panel including necessary thimbling, crimping, taping etc. NOTE:- The cable terminal ends for connection to switchgear at various requisite points shall be Al. Thimbles of dowel’s make and of appropriate size and connected by hydraulic crimp tool only. 50 sqmm , 3.5core |
191 | Supply and fitting of 11 KV polymeric composite pin insulator 12 KV, 5KN, Lighting impulse 75KV Positive, and 80 KV Negative , creep agedistance 320 mm |
192 | Providing and fitting of ACSR as per IS 398 (part-2) 1996 for 50 sq.mmACSR (Galvanized steel reinforced) for fitment of various accessories |
193 | P/F of Galvanized nuts, bolts of various sizes as per site requirement. |
194 | Painting of poles Red oxide |
195 | Painting of poles Aluminum paint |
196 | Providing & Fitting of lighting points in 1.5 mm Sq. multi strand PVC wire as conductor to be laid /carried in PVC channel /conduit as per site requirement. The Job also includes Providing and fitting of 5 Amp. Switch Button /angle holders to be fitted with 15 watt LED Phillips / Havells/Halonix LED inside the Pump house. |
197 | Providing & fitting of heating points in 2.5 sq. multi stand conductor (Make: Havell/ L&T) to be laid & carried in PVC channel/Conduit as per site requirement. The job includes providing and fitting of 16 Amp. Switch socket combine Havells/Phillips/Anchor/ABB. |
198 | Fabricationof6’ x 6’ angle iron bed by way of providingand fitting of Structural steel in built up sections , trusses and framed work, including cutting , hoisting , fixing in position and applying a priming coat of approved steel primer all complete welded |
199 | Providing and fitting of 19 mm thick multilayered ply sheet of size 6 x 3 feet , 2 nos including cutting , fixingall complete including painting of the play sheet by one coat of primer and two coats of enamel paint |
200 | 8.WSS Gadhanjipora (Adv. Cost: Rs. 6,48,590/-) |
201 | Supply, Installation, Testing & Commissioning of 15 HP Submersible Pumping Unitas per IS 8034 with following specification are as under : PUMP : Efficiency = Not less than 50% Speed= 2900 Rpm Type of pump = Mixed flow. Type of fluid to be handled=Clear Water MATERIAL OF CONSTRUCTION: Impeller= Stainless Steel Pump Shaft = Stainless Steel SS 410. Pump Casing = Cast Iron/Stainless steel IMPELLER: Impeller is of the enclosed or semi – enclosed type and properly balanced.Enclosed Impellers equipped with seal rings on their hubs. COUPLING: A suitable coupling arrangement provided with pump set. Non Return Valve:- Non Return Valve of the suitable size provided above the pump discharge case. MOTOR:- Method ofstarting = Star – Delta Speed = 3000 (Sync). Frequency= 50 ± 3 % Hz Working Voltage= 380-415 ± 15% V, 03 phase Efficiency = Not less than 90% Manufacture test certificate to be appended. Rest ofspecification as per Cluase 1of technical anexure of SBD |
202 | Providing and fitting of, Ductile Iron double flanged, non-rising spindle soft seatedglandless gate/ sluice valves as per IS14846 for regulating the water supply outside the pumping units .Size: DN80PN:1.6/16Manufacture test certificate to be appended. Rest ofspecification as per Cluase 12of technical anexure of SBD |
203 | Providing and fitting ofDuctile Iron double flanged, Slanted seatswing check valve (NRV) as per IS 5312. T Size: 80mm PN: 1.6/16 Manufacturers certificate to be apended and detailed specification as perdeatils in cluase 13 of SBD |
204 | Fabrication, Providing and fitting of20 HP Modularmotor control panel of appropriate size fabricated out of 14 SWG sheet having required openings/vents and protection Class as per technical specification of cluase 43d of SBD |
205 | Fabrication of gantry mechanism by way of providing Structural steel in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete welded |
206 | Providing and fitting of MS chequered plate for gantry |
207 | Providing, installation andtestingof manual type triple spur gearchain pulley block along with monorail gearedtravelling trolleyhaving following features: Make = Reputed make Capacity=2 ton (P) No. Of load chain falls = 2 or above Min. Height of lift = 6 M Detailed specification as per cluase 24 of SBD |
208 | Providing, Installation and testing of 2KVA fully automatic voltage stabilizer with input voltage 70-240 V and output 220 V. The stabilizer shall be installed and connected to the electric circuit as per location provided by site incharge. |
209 | Supply, installation, Testing & commissioning of 1000VA Full Sine wave power inverter (Make: Microtek/Luminous) including Providing / Installation of 12V, 180AH Tubular inverter Battery with trolley and cover. (Make: Amaron /Exide) with 2-core 6mm2 Cu wiring as per site requirement along with other accessories like SS-Combine (02 No’s), 3-pin plugs etc of reputed make for proper fitment and installation of the item. |
210 | Illumination of Premises: Providing and erection of 9 Mtr long Hot Dip Galvanized octagonal pole (single Section) with bottom 150mm, top 75mm wide, thickness 3mm with 70 Microns Zinc coating having inside arrangement for providing of power connection along with following items. 1) 3 Way Terminal Connector 20 Amp. 2) 3 No MCB 8 Amp. Rest of the specicifications are as per clause-50 ofTechnical annexure of SBD |
211 | Providing, installation, testing and commissioning of area lighting 120 Watt LED (Street Light Type) on top of octagonal pole vide item No.36 Having following specs: Input: 90-240 V 50 Hz Power Factor: >0.9 Colour Temperature: 4K - 6.5K Beam Angle: 120° - 170° Lumens: >12000 Operating Temperature: -20°C to 60°C Rest of the specicifications are as per clause-51 ofTechnical annexure of SBD |
212 | Providing and installation of Junction Box with DP 32 A MCB to serve as Main switch for LED Lighting. The job includes making of electric connection to the circuit. |
213 | TOOL KIT For Maintenance: - The Tool Kit for maintenance shall comprise of the following and all the items as per Technical specification as per Cluase 57of technical anexure of SBD |
214 | 9.WSS Udaipora Kanlibagh (Adv. Cost: Rs. 13,35,772/-) |
215 | Supply, Installation, Testing & Commissioning of 12.5 HP,non clogPumping Unit as per IS 5600 at Raw Water Stage. PUMP: - Type of pump :non –clogOpen wellSubmersible Vertical Pump Solid Handling Capacity: 20mm (Minimum) Quality of water:Raw water to be handled MOTOR: - Type : Squirrel Cage 3-Phase Induction Motor Sealing : Dual mech. seal. Provided with thermal and overload protection Dual Mechanical Seals (01 No) and Bearings (02 No) for the pumping unit must be provided as spare parts for preventive maintenance by the firm. for each pumping unit Note: Test certificate having the Serial No. of the Pumping Unit along with the performance curve in duplicate from the Manufacturer must be produced on delivery of the item. The main specification of pumping unit are given below Motor Rating :-7.5 HP Manufacturers certificate to be apended and Detailed specifications as per cluase 2 ofSBD |
216 | Supply, Installation, Testing & Commissioning of 15 HP Submersible Pumping Unitas per IS 8034 with following specification are as under : PUMP : Efficiency = Not less than 50% Speed= 2900 Rpm Type of pump = Mixed flow. Type of fluid to be handled=Clear Water MATERIAL OF CONSTRUCTION: Impeller= Stainless Steel Pump Shaft = Stainless Steel SS 410. Pump Casing = Cast Iron/Stainless steel IMPELLER: Impeller is of the enclosed or semi – enclosed type and properly balanced.Enclosed Impellers equipped with seal rings on their hubs. COUPLING: A suitable coupling arrangement provided with pump set. Non Return Valve:- Non Return Valve of the suitable size provided above the pump discharge case. MOTOR:- Method ofstarting = Star – Delta Speed = 3000 (Sync). Frequency= 50 ± 3 % Hz Working Voltage= 380-415 ± 15% V, 03 phase Efficiency = Not less than 90% Manufacture test certificate to be appended. Rest ofspecification as per Cluase 1of technical anexure of SBD |
217 | Providing and fitting ofDuctile Iron double flanged, Slanted seatswing check valve( NRV) as per IS 5312. Manufacture test certificate to be appended. Rest ofspecification as per Cluase 13of technical anexure of SBD size100 mm |
218 | Providing and fitting of, Ductile Iron double flanged, non-rising spindle soft seatedglandless gate/ sluice valves as per IS14846 for regulating the water supply outside the pumping units . Manufacture test certificate to be appended. Rest ofspecification as per Cluase 12of technical anexure of SBD size100 mm |
219 | Fabrication, Providing and fitting of20 HP Modularmotor control panel of appropriate size fabricated out of 14 SWG sheet having required openings/vents and protection Class : IP-55 & fitted with accessories as per technical specifcation of cluase 43 dof SBD |
220 | Earth work in bulk excavation by mechanical means in trenches for foundations, drains, pipes, cables etc (not exceeding 1.5m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan , including dressing of sides and reaming of bottom lift upto 1.5 m , including getting out excavated earth and disposal of surplus excavated earth as directed. (All kinds of soil 01 meter from cutting edge) |
221 | Fitting of departmental 20ft long (13nos), GI 100mm dia flannged pipeto replace the exiting 80 mm rising main from raw water to pre setling tank. The job includes providing, fitting of nuts, bolts, washers and all skilled labour etc, complete.The rising main is to be laidas per the instructions of the site incharge. |
222 | Fabrication of gantry mechanism by way of providing Structural steel in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete welded |
223 | Providing, installation andtestingof manual type triple spur gearchain pulley block along with monorail gearedtravelling trolleyhaving following features Capacity=2 ton (P) No. Of load chain falls = 2 or above Min. Height of lift = 6 M Detailed Techinical specification as per cluase 24 of SBD |
224 | Providing, fitting, testing and commissioning ofvoltage stabilizeras per specifications below: Type of voltage controller: Manually operated copper wound, 3-phase, AC power supply multi step. Type of Regulator: Double plate type with electrolytic copper contacts. Input voltage : 175-400 volts.(3 phase) Output voltage : 400 ±10% volts. Frequency : 50±3 C/S. Windings : Electrolytic grade copper of adequate section, vacuum impregnated and Oven-dried. Insulation : Fiber glass insulations to tested parameters. Cooling: Naturally, Oil cooled Temp. Rise (Max) : 30°C above ambient Mounting : On Uni-directional wheels. Correction rate : 30 volts per step Wave form distortion: virtually nil Duty cycle : 100% continuous. Enclosure : MS sheet enclosure in pressed CGR Sheet powder coated with radiators. Core laminates: High grade, low eddy loss, grain oriented silicon steel laminations. Load: Three phase induction motor load. Load Amperes (continuous) Rating::40KVA Rest ofTechnical specification as per Cluase 45 of technical anexure of SBD |
225 | Removal of choked filter media from 5000/ 6000 GPH pressure filter vessel. The job includes all loads and lifts, disposal of choked media to dumping site outside the premises of the plant within a lead of 5 km. The vessel needs to be cleaned properly and dried before laying of fresh media. |
226 | Providing and layingof filter media of specific size and grade (preferably from sindh Nallah Ganderbal) to be laid in 5000/6000 GPH Pressure vessel duly washed, free from dust, dirt, loom and any other inorganic materialor suspension, the job includes carriage of filtermedia from Ganderbalto site including allall loads and liftsrequired on the site condition. The media is to be lad in different layers of specific size and grade from bottom to top over the filter bed plate. The bottom layer is to be laid without tilling/damaging the pressure nozzles |
227 | Providing and fitting of 12 mm dia. Fine threaded PVC nozzles auxiliary type to be fitted on filter bed plate of pressure vessel. |
228 | Providing and fitting of 29 inch. dia. rubber washers /gaskets for manhole and inspection chamber and opening of pressure filter vessel. |
229 | Providing and fitting of 3”x5/8” nuts and bolts. |
230 | Painting with synthetic enamel paint two or more coats of approved brand and bor pressure clarifier pressure filter vessel, fittings and complete piping after cleaning of dirt by kerosene oil and application of steel primer of specific grade. |
231 | P/I/T/C of horizontal monoblock pumping equipment of following parameters; a) Discharge :-6000GPH, b) Head: 30 meters. c) Speed: 1440 rpmThe pump & motor should be mounted on a suitable size MS base frame . The Job also includes P/F of foundation bolts |
232 | Providing, fabrication and fitting of welded MS wire mesh (0.50 sq. inch and 1.40mm wire dia. for Bird screening to the CGI Pressure Filter House. |
233 | Replacement of 25 mm dia. -03 no’s (Ball Valves-Reputed make) The job includes providing and fitting of nuts and bolts and washers with allied mechanical works. The job includes Providing, fitting of25mm dia.GI-6 mtrs with necessary fittings as per requirement. |
234 | Replacement of 80 mm dia butterfly valve with pressure |
235 | Replacement of 65 mm Butterfly valves |
236 | Providing and fitting80 mm dia MS flanged pipe to be laid pumping unit at PST to filter vessele(class C) |
237 | Providing, installation, testing and commissioning of area lighting 120 Watt LED (Street Light Type) insidevide item No.36 Having following specs: Input: 90-240 V 50 Hz Power Factor: >0.9 Colour Temperature: 4K - 6.5K Beam Angle: 120° - 170° Lumens: >12000 Operating Temperature: -20°C to 60°C Rest ofTechnical specification as per Cluase 52of technical anexure of SBD |
238 | Replacement of agitator in alum solution holding tank fabricated out of wetted parts in stainlessspeed 20-30 intermediate bearing type twin blades free standing type |
239 | Providing and fitting of Dozing pumps to be doze required quantity of alum /chlorine in the system .The capacity of the dozing units shall be 12-20 LPH capaicity withh all acessories |
240 | Providing and fitting of pressure gauges with adopters to replace damaged ones these pressure gauges should be in the range of 0-50 kgf/cm/sg and be reputed make. |
241 | P/I/T/of5 H.P. DOLstarter |
242 | Supply, installation, errection of9 mtrs long ST- 410 (sp-33) . The job further includes drilling of holes for installation of various accessories .wherever required. The job further includes GI wire earthing of pole as per REC standard. |
243 | Supply, Installation, Testing and commissioning of Polymeric Gang operated Air break switch, outdoor type, triple pole, suitable for vertical installation, single break provided with locking arrangement at both ON and OFF position consisting ofHT post double insulator, copper or copper alloy high pressure heavy contact assembly, rod with bearings , operating handle and 2 length of 32mm dia. GI pipe conforming to IS 1818 1961, 06 No. of insulators, rated voltage 11KV 200A complete as per IS specs. |
244 | Providing and fittingG.I Channel /Angle/ Flat of sizes including clamps |
245 | Supply, Installation, Testing and commissioning of 11KVpolymer fuses SetHorn Gap3-phase 200 Asuitable for vertical installation . |
246 | Supply, Installation, Testing and commissioning ofGapless Surgearrestor station class, 10KA, 9KV, LA With polymer housing , Station Type . |
247 | Supply and fitting of 11 KV polymeric composite pin insulator 12 KV, 5KN, Lighting impulse 75KV Positive, and 80 KV Negative , creepagedistance 320 mm |
248 | Providing and fitting of ACSR as per IS 398 (part-2) 1996 for 50 sq.mmACSR (Galvanised steel reinforced) for fitment of various accessories |
249 | Painting of poles Red oxide |
250 | Painting of poles Aluminum paint |
251 | P/F of Galvanized nuts, bolts of various sizes as per site requirement. |
252 | Providing and fitting of 12mm thick ply board as roofing to operators room as per instructions of Site Engineer. The job includes P/F of nails, labour, carriage etc, complete in all respects |
253 | Providing and Fitting of three/single-Core, copper pvc insulated Cable, XLPE armoured conforming to IS: 7089 part 1st for intedrnal connectionscrimping, taping etc. NOTE:- The cable terminal ends for connection to switchgear at various requisite points shall be Al. Thimbles and of appropriate size and connected by hydraulic crimp tool only. Single core PVC insulated 25sqmm |
254 | Providing and fitting of 3-Core flatsubmersible copper cable conforming to IS: 694 (Part 1st) – 1964 & IS: 694 (Part 2nd) - 1964 for Submersible Pumping Unit and other electrical Equipments . The cable connections terminal shall be fitted with copper thimbles of required size. Size: 16 sq.mm |
255 | Providing and Fitting of 3 /3.5/2-Core, XLPE Armoured Aluminium Cable conforming to IS: 7089 part 1st as service line from the HT transformer to control panel including necessary thimbling, crimping, taping etc. NOTE:- The cable terminal ends for connection to switchgear at various requisite points shall be Al. Thimbles of dowel’s make and of appropriate size and connected by hydraulic crimp tool only. i) 50 sqmm, 3.5core |
256 | TOOL KIT For Maintenance: - The Tool Kit for maintenance shall comprise of the following and all the items as per Technical specification as per Cluase 57of technical anexure of SBD |
257 | Supply, installation, Testing & commissioning of 1000VA Full Sine wave power inverter (Make: Microtek/Luminous) including Providing / Installation of 12V, 180AH Tubular inverter Battery with trolley and cover with 2-core 6mm2 Cu wiring as per site requirement along with other accessories like SS-Combine (02 No’s), 3-pin plugs etc of reputed make for proper fitment and installation of the item. |
258 | Providing, installation, testing and commissioning of area lighting 120 Watt LED (Street Light Type) insidevide item No.36 Having following specs: Input: 90-240 V 50 Hz Power Factor: >0.9 Colour Temperature: 4K - 6.5K Beam Angle: 120° - 170° Lumens: >12000 Operating Temperature: -20°C to 60°C Rest ofTechnical specification as per Cluase 51of technical anexure of SBD |
259 | Providing, Installation and testing of 2KVA fully automatic voltage stabilizer with input voltage 70-240 V and output 220 V. The stabilizer shall be installed and connected to the electric circuit as per location provided by site incharge. |
260 | Providing and installation of Junction Box with DP 32 A MCB to serve as Main switch for LED Lighting. The job includes making of electric connection to the circuit. |
261 | Providing & Fitting of lighting points in 1.5 mm Sq. multi strand PVC wire as conductor to be laid /carried in PVC channel /conduit as per site requirement. The Job also includes Providing and fitting of 5 Amp. Switch Button /angle holders to be fitted with 15 wattLED inside the Pump house. |
262 | Providing & fitting of heating points in 2.5 sq. multi stand conductorto be laid & carried in PVC channel/Conduit as per site requirement. The job includes providing and fitting of 16 Amp. Switch socket of approved make. |
263 | 10.WSS Mohanviji (Adv. Cost: Rs. 15,07,066/-) |
264 | Supply, Installation, Testing & Commissioning of 12.5 HP, non clogPumping Unit as per IS5600at Raw Water Stage. PUMP: - Type of pump :non –clogOpen wellSubmersible Vertical Pump Solid Handling Capacity: 20mm (Minimum) Quality of water:Raw water to be handled MOTOR: - Type : Squirrel Cage 3-Phase Induction Motor Sealing :Dual mech. seal. Provided with thermal and overload protection Manufacturers certificate to be apended and Detailed specifications as perclause 2 of SBD |
265 | Supply, Installation, Testing & Commissioning of 15 HP Submersible Pumping Unitas per IS 8034 with following specification are as under : PUMP : Efficiency = Not less than 50% Speed= 2900 Rpm Type of pump = Mixed flow. Type of fluid to be handled=Clear Water MATERIAL OF CONSTRUCTION: Impeller= Stainless Steel Pump Shaft = Stainless Steel SS 410. Pump Casing = Cast Iron/Stainless steel IMPELLER: Impeller is of the enclosed or semi – enclosed type and properly balanced.Enclosed Impellers equipped with seal rings on their hubs. COUPLING: A suitable coupling arrangement provided with pump set. Non Return Valve:- Non Return Valve of the suitable size provided above the pump discharge case. MOTOR:- Method ofstarting = Star – Delta Speed = 3000 (Sync). Frequency= 50 ± 3 % Hz Working Voltage= 380-415 ± 15% V, 03 phase Efficiency = Not less than 90% Manufacture test certificate to be appended. Rest ofspecification as per Cluase 1of technical anexure of SBD |
266 | Providing and fitting of, Ductile Iron double flanged, non-rising spindle soft seatedglandless gate/ sluice valves as per IS14846 for regulating the water supply outside the pumping units .Size: DN80PN:1.6/16Manufacture test certificate to be appended. Rest ofspecification as per Cluase 12of technical anexure of SBD |
267 | Providing and fitting ofDuctile Iron double flanged, Slanted seatswing check valve (NRV) as per IS 5312. The body shall be of ductile cast iron with fully encapsulated vulcanized EPDM rubber(Approved for drinking water). Size: 80mm PN: 1.6/16 Manufacturers test certificate to be apended and detailed specification as per cluase 13 of SBD |
268 | Fabrication, Providing and fitting of20 HP Modularmotor control panel of appropriate size fabricated out of 14 SWG sheet having required openings/vents and protection Class : IP-55 & fitted with accessories as per technical specifcation of cluase 43d of SBD |
269 | Providing, fitting, testing and commissioning ofvoltage stabilizeras per specifications below: Type of voltage controller: Manually operated copper wound, 3-phase, AC power supply multi step. Type of Regulator: Double plate type with electrolytic copper contacts. Input voltage : 250-400 volts.(3 phase) Output voltage : 400 ±10% volts. Frequency : 50±3 C/S. Rating: 50KVA Deatailed specification as per cluase 44 of SBD |
270 | Fabrication of gantry mechanism by way of providing Structural steel in built up sections , trusses and framed work, including cutting , hoisting , fixing in position and applying a priming coat of approved steel primer all complete welded |
271 | Providing, installation andtestingof manual type triple spur gearchain pulley block along with monorail gearedtravelling trolleyhaving following features Capacity=2 ton (P) No. Of load chain falls = 2 or above Min. Height of lift = 6 M Detailed Techinical specification as per cluase 24 of SBD |
272 | Removal of choked filter media from 5000/ 6000 GPH pressure filter vessel. The job includes all loads and lifts, disposal of choked media to dumping site outside the premises of the plant within a lead of 5 km. The vessel needs to be cleaned properly and dried before laying of fresh media. |
273 | Providing and layingof filter media of specific size and grade (preferably from sindh Nallah Ganderbal) to be laid in 5000/6000 GPH Pressure vessel duly washed, free from dust, dirt, loom and any other inorganic materialor suspension .the job includes carriage of filtermedia from Ganderbalto site including allall loads and liftsrequired on the site condition. The media is to be lad in different layers of specific size and grade from bottom to top over the filter bed plate. The bottom layer is to be laid without tilling/damaging the pressure nozzles |
274 | Providing and fitting of 12 mm dia. Fine threaded PVC nozzles auxiliary type to be fitted on filter bed plate of pressure vessel. |
275 | Providing and fitting of 29 inch dia. rubber washers /gaskets for manhole and inspection chamber and opening of pressure filter vessel. |
276 | Providing and fitting of 3”x5/8” nuts and bolts. |
277 | Painting with synthetic enamel paint two or more coats of approved brand and bor pressure clarifier pressure filter vessel, fittings and complete piping after cleaning of dirt by kerosene oil and application of steel primer of specific grade. |
278 | P/I/T/C of horizontal monoblock pumping equipment of following parameters; a) Discharge :-6000GPH, b) Head: 30 meters. c) Speed: 1440 rpmThe pump & motor should be mounted on a suitable size MS base frame. The Job also includes P/F of foundation bolts |
279 | P/I/T/C of backwash pumping equipment of following parameters Discharge-16 lps HP-5, Head range 6-15mtr |
280 | P/I/T/C of air scavenging/blower unit of following parameters Capacity: -50 CFM, Pressure: -5PS10, Speed: -1450 RPM Motor as per requirment |
281 | Providing, fabrication and fitting of welded MS wire mesh (0.50 sq. inch and 1.40mm wire dia. for Bird screening to the CGI Pressure Filter House. |
282 | Replacement of 25 mm dia. -03 no’s (Ball Valves-Reputed make) The job includes providing and fitting of nuts and bolts and washers with allied mechanical works. The job includes Providing, fitting of25mm dia.GI-6 mtrs with necessary fittings as per requirement. |
283 | Replacement of 80 mm dia cast iron diaphram valves by D.I gate valve/ butterfly valve with pressure rating of PN16 |
284 | Replacement of 65 mm Butterfly valvesof PN16 |
285 | Replacement of agitator in alum solution holding tank fabricated out of wetted parts in stainlessspeed 20-30 intermediate bearing type twin blades free standing type |
286 | Providing and fitting of Dozing pumps to be doze required quantity of alum/chlorine in the system .The capacity of the dozing units shall be 12-20 LPH capaicity withh all acessories |
287 | P/F/Welding of 80 mm flanges to the existing piping system |
288 | Providing and fitting of, 50 mm NRV |
289 | P/F/Welding of 50 mm flanges to the existing piping system after cutting the damaged ones. |
290 | Providing and fitting of 3-Core6mm sq flatsubmersible copper cable conforming to IS: 694 (Part 1st) – 1964 & IS: 694 (Part 2nd) - 1964 for Submersible Pumping Unit and other electrical Equipments . The cable connections terminal shall be fitted with copper thimbles of required size. |
291 | P/I/T/of5 H.P. DOLstarter |
292 | Providing and fitting of pressure gauges with adopters to replace damaged ones these pressure gauges should be in the range of 0-50 kgf/cm/sg and be reputed make. |
293 | Providing, installation, testing and commissioning of area lighting 120 Watt LED (Street Light Type) insidevide item No.36 Having following specs: Input: 90-240 V 50 Hz Power Factor: >0.9 Colour Temperature: 4K - 6.5K Beam Angle: 120° - 170° Lumens: >12000 Operating Temperature: -20°C to 60°C Rest ofTechnical specification as per Cluase 51of technical anexure of SBD |
294 | Providing/supplying and fitting of 80 G.I flanged pipe from inlet/preset lingtank to sumpThe Pipe shall be hot dip Galvanized, class BC confirming to IS 1239. The job includes providing and fitting of M.S Flanges conforming to BIS 6392/1997 Table 17 (Rating PN16). The flanges shall be double welded both from inside and outside of the pipe using standard electrode of reputed make.Flanges (as per IS 6392/1997 Table:17) Thickness shall conform to IS 6392 Part 1st Table-17. |
295 | Providing and fitting of 12mm thick ply board as roofing to operators room as per instructions of Site Engineer. The job includes P/F of nails, labour, carriage etc, complete in all respects |
296 | Providing & Fitting of lighting points in 1.5 mm Sq. multi strand PVC wire as conductor to be laid /carried in PVC channel /conduit as per site requirement. The Job also includes Providing and fitting of 5 Amp. Switch Button /angle holders to be fitted with 15 watt LEDinside the Pump house. |
297 | Providing & fitting of heating points in 2.5 sq. multi stand conductor to be laid & carried in PVC channel/Conduit as per site requirement. The job includes providing and fitting of 16 Amp. Switch socket combine |
298 | Illumination of Premises: Providing and erection of 9 Mtr long Hot Dip Galvanized octagonal pole (single Section) with bottom 150mm, top 75mm wide, thickness 3mm with 70 Microns Zinc coating having inside arrangement for providing of power connection along with following items. 1) 3 Way Terminal Connector 20 Amp. 2) 3 No MCB 8 Amp. Rest of theTechnical specicifications are as per clause-50 ofTechnical annexure of SBD |
299 | Providing and installation of Junction Box with DP 32 A MCB to serve as Main switch for LED Lighting. The job includes making of electric connection to the circuit. |
300 | Providing, Installation and testing of 2KVA fully automatic voltage stabilizer with input voltage 70-240 V and output 220 V. The stabilizer shall be installed and connected to the electric circuit as per location provided by site incharge. |
301 | Providing, installation, testing and commissioning of area lighting 120 Watt LED (Street Light Type) on top of octagonal pole vide item No.36 Having following specs: Input: 90-240 V 50 Hz Power Factor: >0.9 Colour Temperature: 4K - 6.5K Beam Angle: 120° - 170° Lumens: >12000 Operating Temperature: -20°C to 60°C Rest of the specicifications are as per clause-51ofTechnical annexure of SBD |
302 | Fabricationof6’ x 6’ angle iron bed by way of providingand fitting of Structural steel in built up sections , trusses and framed work, including cutting , hoisting , fixing in position and applying a priming coat of approved steel primer all complete welded |
303 | Providing and fitting of 19 mm thick multilayered ply sheet of size 6 x 3 feet, 2 nos including cutting , fixingall complete including painting of the play sheet by one coat of primer and two coats of enamel paint |
304 | 11.WSS Lelhar (Adv. Cost: Rs. 12,92,743/-) |
305 | Supply, Installation, Testing & Commissioning of, non clog10 HP Pumping Unit as per IS 5600 at Raw Water Stage. PUMP: - Type of pump:non –clogOpen wellSubmersible Vertical Pump Solid Handling Capacity: 20mm (Minimum) Quality of water:Raw water to be handled MOTOR: - Type : Squirrel Cage 3-Phase Induction Motor Sealing:Dual mech. seal. Provided with thermal and overload protection Dual Mechanical Seals (01 No) and Bearings (02 No) for the pumping unit must be provided as spare parts for preventive maintenance by the firm. for each pumping unit Note: Test certificate having the Serial No. of the Pumping Unit along with the performance curve in duplicate from the Manufacturer must be produced on delivery of the item. The main specification of pumping unit are given below Manufacturers test certificate to be apended andDetailed specifications as per cluase 2 SBD |
306 | Supply, Installation, Testing & Commissioning of 20 HP Submersible Pumping Unitas per IS 8034 with following specification are as under : PUMP : Efficiency = Not less than 50% Speed= 2900 Rpm Type of pump = Mixed flow. Type of fluid to be handled=Clear Water MATERIAL OF CONSTRUCTION: Impeller= Stainless Steel Pump Shaft = Stainless Steel SS 410. Pump Casing = Cast Iron/Stainless steel IMPELLER: Impeller is of the enclosed or semi – enclosed type and properly balanced.Enclosed Impellers equipped with seal rings on their hubs. COUPLING: A suitable coupling arrangement provided with pump set. Non Return Valve:- Non Return Valve of the suitable size provided above the pump discharge case. MOTOR:- Method ofstarting = Star – Delta Speed = 3000 (Sync). Frequency= 50 ± 3 % Hz Working Voltage= 380-415 ± 15% V, 03 phase Efficiency = Not less than 90% Manufacture test certificate to be appended. Rest ofspecification as per Cluase 1of technical anexure of SBD |
307 | Providing and fitting ofDuctile Iron double flanged, Slanted seatswing check valve (NRV) as per IS 5312. The body shall be of ductile cast iron with fully encapsulated vulcanized EPDM rubber(Approved for drinking water). Size: 80mm PN: 1.6/16 Manufacturers test certificate to be apended and Detailed specifications as per cluase 13 SBD |
308 | Providing/supplying and fitting ofG.I flanged Rising Main at site. The Pipe shall be hot dip Galvanized, class-C confirming to IS 1239. The job includes providing and fitting of M.S Flanges conforming to BIS 6392/1997 Table 17 (Rating PN16). The flanges shall be double welded both from inside and outside of the pipe using standard electrode of reputed make. Flanges (as per IS 6392/1997 Table:17) Thickness shall conform to IS 6392 Part 1st Table-17. T Size : DN80 Class: C (Heavy). Manufacture test certificate to be appended. Rest ofTechnical specification as per Cluase 8of technical anexure of SBD |
309 | Fabrication, Providing and fitting oflong radius bend to be fabricated out ofG.I pipe, flanged on both ends ato make it leak proof. The flanges shall be M.S Flanges conforming to BIS 6392/1997 Table 17 (Rating PN16) and welded on both sides. The job includes nuts, bolts, gaskets etc as per site requirement. Size:DN 80 Class: C |
310 | Supply, installation, commissioning and Creation of pole mounted, outdoor type Electric Sub Stationby way ofS/I/T/C of 11/0.433 KVA , 3 Phase Distribution Transformer with Bimetallic Terminal connectors Energy level -2 Aluminum wound Specifications conforming to IS : 1180 (Part 1) 2014 with latest amendments Type of cooling:ONAN. Rating: 100 KVA HT Transformer, 3 phase (Level 2). Manufacture test certificate to be appended. Rest ofspecification as per Cluase 26 of technical anexure of SBD |
311 | Fabrication, Providing and fitting of20 HP Modularmotor control panel of appropriate size fabricated out of 14 SWG sheet having required openings/vents and protection Class : IP-55 & fitted with accessories. Rest of specification as per Cluase 43 d of technical anexure of SBD |
312 | Providing, fitting, testing and commissioning ofvoltage stabilizeras per specifications below: Type of voltage controller: Manually operated copper wound, 3-phase, AC power supply multi step. Type of Regulator: Double plate type with electrolytic copper contacts. Input voltage : 250-400 volts.(3 phase) Output voltage : 400 ±10% volts. Frequency : 50±3 C/S. Rating::75KVA Detailed specification as per cluase 45 of SBD |
313 | Providing, installation andtestingof manual type triple spur gearchain pulley block along with monorail gearedtravelling trolleyhaving following features Gears:- The hoist shall have precision machine case Hardened alloy steel gear mounted on bearings and housed in a dust proof gear box. The lubrication of gears should be of high viscosity and temperature for longer life of gears. Capacity=2 ton (P) No. Of load chain falls = 2 or above Min. Height of lift = 6 M Rest ofspecification as per Cluase 24 of technical anexure of SBD |
314 | Providing and fitting of 3-Core flatsubmersible copper cable conforming to IS: 694 (Part 1st) – 1964 & IS: 694 (Part 2nd) - 1964 for Submersible Pumping Unit and other electrical Equipments . The cable connections terminal shall be fitted with copper thimbles of required size. Size: 16sq.mm |
315 | Providing, installation, testing and commissioning of area lighting 120 Watt LED (Street Light Type) on top of octagonal pole vide item No.36 Having following specs: Input: 90-240 V 50 Hz Power Factor: >0.9 Colour Temperature: 4K - 6.5K Beam Angle: 120° - 170° Lumens: >12000 Operating Temperature: -20°C to 60°C Rest of the specicifications are as per clause-51 ofTechnical annexure of SBD |
316 | Providing, Installation and testing of 2KVA fully automatic voltage stabilizer with input voltage 70-240 V and output 220 V. The stabilizer shall be installed and connected to the electric circuit as per location provided by site incharge. |
317 | Providing and installation of Junction Box with DP 32 A MCB to serve as Main switch for LED Lighting. The job includes making of electric connection to the circuit. |
318 | Supply, installation, Testing & commissioning of 1000VA Full Sine wave power inverterincluding Providing / Installation of 12V, 180AH Tubular inverter Battery with trolley and cover with 2-core 6mm2 Cu wiring as per site requirement along with other accessories like SS-Combine (02 No’s), 3-pin plugs etc of reputed make for proper fitment and installation of the item. |
319 | Providing various conveince and utilityitems to on duty staff as per Technical specification as per Cluase 58of technical anexure of SBD |
320 | Providing of bamboo ladders 18 feet long along with 15 feet long Link rods and HT Glove pair (01 No each) |
321 | Fabricationof6’ x 6’ angle iron bed by way of providingand fitting of Structural steel in built up sections , trusses and framed work, including cutting , hoisting , fixing in position and applying a priming coat of approved steel primer all complete welded |
322 | Providing and fitting of 19 mm thick multilayered ply sheet of size 6 x 3 feet , 2 nos including cutting , fixingall complete including painting of the play sheet by one coat of primer and two coats of enamel paint |
323 | TOOL KIT For Maintenance: - The Tool Kit for maintenance shall comprise of the following and all the items as per Technical specification as per Cluase 57of technical anexure of SBD |
324 | Providing & Fitting of lighting points in 1.5 mm Sq. multi strand PVC wire as conductor to be laid /carried in PVC channel /conduit as per site requirement. The Job also includes Providing and fitting of 5 Amp. Switch Button /angle holders to be fitted with 15 watt LED inside the Pump house. |
325 | Providing & fitting of heating points in 2.5 sq. multi stand conductorto be laid & carried in PVC channel/Conduit as per site requirement. The job includes providing and fitting of 16 Amp. Switch socket combine . |
326 | 12.WSS Khennibugh (Adv. Cost: Rs. 16,85,275/-) |
327 | Supply, Installation, Testing & Commissioning of Submersible Pumping Unit as per IS 8034 with following specification are as under: PUMP: Efficiency = Not less than 50% Speed = 2900 Rpm Type of pump = Mixed flow. Type Rest specifications as per clause -1 of SBD motor rating =25HP |
328 | Supply, installation, testing and commissioning of Horizontalpumping unit as per IS 1520 with following specification:- Pump:- 1.Type :-Horizontal monoblock Material of construction 1.Impeller:- S.steel 2.Shaft:-SS410 motor rating :5 HP or sutible for above parameters Manufactures Test Certificate to be apended and detailed specification as per cluase "5" of of SBD |
329 | Providing/supplying and fitting ofG.I flanged Rising Main at site. The Pipe shall be hot dip Galvanized, class-C confirming to IS 1239. The job includes providing and fitting of M.S Flanges conforming to BIS 6392/1997 Table 17 (Rating PN16). The flanges shall be double welded both from inside and outside of the pipe using standard electrode of reputed make. Flanges (as per IS 6392/1997 Table:17) Thickness shall conform to IS 6392 Part 1st Table-17. The flange welding shall be carried out in double layers using reputed make electrodes to form strong welding joint. Welding Electrode DC Arc Welding using welding electrode having diameter not less than 4mm. Nuts and Bolts Nuts and Bolts (conforming to IS:1363 Part 1st) Rubber Insertion Gaskets Rubber Insertion Gaskets (conforming to IS: 638/79) to be used between flanged joints. The rising main is to be laid as per the instructions of the engineer in charge and site requirement. the size of the pipe is given below: Size : DN 100 Class: C (Heavy) |
330 | Size : DN 80 Class: C (Heavy) |
331 | Earth work in excavation by manual means in trenches for foundation, drains, pipes, cables (not exceeding 1.5 m in width ) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and reaming of bottom lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed. (All kinds of soil 01 meter from cutting edge) |
332 | Filling available excavated earth in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by reaming and watering, lead upto 50 m and lift upto 1.5m. |
333 | Fabrication, providing and fitting of split type MS clamps10 mm thick, 2 ft long and 3 inch wide for lowering and holding of pumping unit fitted. The job includes the cost of required size of nuts and bolts. Size: 80mm |
334 | Fabrication, Providing and fitting of90-120 degree bend/elbowto be fabricated out ofG.I pipe, 1 m lengthand flanged on both ends ato make it leak proof. The flanges shall be M.S Flanges conforming to BIS 6392/1997 Table 17 (Rating PN16) and welded on both sides. The job includes nuts, bolts, gaskets etc as per site requirement. Size:DN 80 Class: C |
335 | Size:DN 100 Class: C |
336 | Cutting of hot dip galvanized G.I,pipe across the section by dint of pipe cutter/ gas cutter. The job also includes Providing and welding of M.S flanges to the two ends of pipe. The Thickness of flange shall conform to IS 6392 Part 1st Table-17. The flange welding shall be carried out in double layers using Advani/Esab/L&T- SS Bond make electrodes to form strong welding joint by dint of DC arc welding. The job further includes Providing and Fitting of nuts and bolts (conforming to IS:1363 Part 1st) and Rubber Insertion Gaskets (conforming to IS: 638/79) to be used between flanged joints. The size of pipe is given below: Size: DN80 PN:1.6/16 |
337 | Size: DN 100 PN:1.6/16 |
338 | Fabrication, Providing and fitting of Y- junction having 1m length of each armto be fabricated out ofhot dip galvanized G.I, C-Class pipe. The job also includes Providing and welding of M.S flanges to the ends of each arm. the Thickness of flange shall conform to IS 6392 Part 1st Table-17. The flange welding shall be carried out in double layers using reputed make electrodes to form strong welding joint by dint of DC arc welding. The job further includes Providing and Fitting of nuts and bolts (conforming to IS:1363 Part 1st) and Rubber Insertion Gaskets (conforming to IS: 638/79) to be used between flanged joints. The size of the Y- junction is given below : size : DN 80, Class - C |
339 | Fabrication, providing and fitting of washout Tee with arm length 1.2 feet each. The Tee shall be fabricated out of G.I pipe with M.S Flanges conforming to BIS 6392/1997 Table 17 (Rating PN16) fastened with weld joints on three ends. Size: 100mm Class: C class |
340 | Size: 80mm Class: C class |
341 | Providing and fitting of Ductile Iron double flanged, non-rising spindle soft seatedglandless gate/ sluice valves as per IS14846 for regulating the water supply outside the pumping units . The body and bonnent of the valve shall be of ductileiron, wedge with fully vulcanized EPDM rubber(Approved for drinking water) and NBR seal. The Gate/Sluice valve shall be compatible for buried applications and shall be safe to install in both horizontal and vertical positions It shall have electrostatic epoxy coating(approved for drinking water) both inside and outside of the valve. The valve shall be supplied along with hand wheel. Cost on account of Nuts, bolts, gaskets, etc required for the job is included in the scope of work. The job includes providing and fitting of 02 nos. M.S flanges perfectly adaptable to the inbuilt flanges of the valve which shall be fitted with rising main of the pumping unit at appropriate spots as per site requirement. Size: DN 100 PN:1.6/16 |
342 | Size: DN80 PN:1.6/16 |
343 | Providing and fitting ofDuctile Iron double flanged, Slanted seatswing check valve( NRV) as per IS 5312. The body shall be of ductile cast iron with fully encapsulated vulcanized EPDM rubber(Approved for drinking water). The valve shall be compatible for buried applications and shall be safe to install in both horizontal and vertical positions. It shall have electrostatic epoxy coating (approved for drinking water) both inside and outside of the valve. Cost on account of Nuts, bolts, gaskets, etc required for the job is included in the scope of work. The job includes providing and fitting of 02 nos. M.S flanges perfectly adaptable to the inbuilt flanges of the valve which shall be fitted with Rising main of the pumping unit at appropriate spots as per site requirement. Size: 80mm PN: 1.6/16 |
344 | Size: DN100 PN: 1.6/16 |
345 | Providing, fitting, testing and commissioning of DN 50, PN 1.6/16ARV (Air Release valve) as per IS 14845 to be fitted toG.Irising Main ... the ARV Shall have the following specifications: - i. Valve type -single chamber, single orifice. ii. End connection-flanged ends to IS 1538 iii. Working temperature- 70oc to 550 c iv. Test pressure - body / seat 2.5 x PN v. Sealing ring -EPDM vi. Construction-ductile iron with stainless steelfloats vii. Coating -epoxy with corrosion resistance Besides the above works, The job also cost on account of P/F R.I gasket, nuts and bolts required for installation of ARV and arrangement of gas cutter/ welding set at site. |
346 | Providing, installation andtestingof manual type triple spur gearchain pulley block along with monorail gearedtravelling trolleyhaving following features. Gears:- The hoist shall have precision machine case Hardened alloy steel gear mounted on bearings and housed in a dust proof gear box. The lubrication of gears should be of high viscosity and temperature for longer life of gears. Load Chain:-The load chain be made of high tensile alloy steel having wear resistance and greatest mobility. The chain should be accurately collaborated, tested and have adequate in built factor of safety for safer operation. Load chain wheel:- the load chain well should be double ball bearing supported andSpecially designed, perfectly machined wheel providing correct grip of load chaintomakes the hoist most safe and reliable against any failure. The main specifications of C.P Block are given below : Make = Reputed make Capacity=3ton No. Of load chain falls = 2 or above Min. Height of lift = 6 M |
347 | Supply, Installation, Testing and commissioning of Polymeric Gang operated Air break switch, outdoor type, triple pole, suitable for vertical installation, single break provided with locking arrangement at both ON and OFF position consisting ofHT post double insulator, copper or copper alloy high pressure heavy contact assembly, rod with bearings , operating handle and 2 length of 32mm dia. GI pipe conforming to IS 1818 1961, 06 No. of insulators, rated voltage 11KV 200A complete as per IS specs. |
348 | Supply, Installation, Testing and commissioning of 11KVpolymer fuses SetHorn Gap3-phase 200 Asuitable for vertical installation . |
349 | Supply and fitting of 11 KV polymeric composite pin insulator 12 KV, 5KN, Lighting impulse 75KV Positive, and 80 KV Negative , creepagedistance 320 mm |
350 | P/F of Galvanized nuts, bolts of various sizes as per site requirement. |
351 | Providing and fitting of ACSR as per IS 398 (part-2) 1996 for 50 sq.mmACSR (Galvanised steel reinforced) for fitment of various accessories |
352 | Fabrication, Providing and fitting ofModularmotor control panel of appropriate size fabricated out of 14 SWG sheet having required openings/vents and protection Class : IP-55 & fitted with accessories as under: MU-G 10 rest specifications as per cluase - 43-Bof SBD |
353 | Fabrication, Providing and fitting ofModularmotor control panel of appropriate size fabricated out of 14 SWG sheet having required openings/vents and protection Class : IP-55 & fitted with accessories as under: MU-G 30 rest specifications as per cluase - 43-Eof SBD |
354 | Providing, fitting, testing and commissioning ofvoltage stabilizeras per specifications below: Type of voltage controller: Manually operated copper wound, 3-phase, AC power supply multi step. Type of Regulator: Double plate type with electrolytic copper contacts. Input voltage : 250-400 volts.(3 phase) Output voltage : 400 ±10% volts. Frequency : 50±3 C/S. Rest specifications as per Clause - 44 of SBD Rating::50KVA |
355 | Providing and fitting of 3-Core flatsubmersible copper cable conforming to IS: 694 (Part 1st) – 1964 & IS: 694 (Part 2nd) - 1964 for Submersible Pumping Unit and other electrical Equipments . The cable connections terminal shall be fitted with copper thimbles of required size. Size 10 Sq.mm |
356 | Size: 6 Sq.mm |
357 | Providing and Fitting of 3 /3.5/2-Core, XLPE Armoured Aluminium Cable conforming to IS: 7089 part 1st as service line from the HT transformer to control panel including necessary thimbling, crimping, taping etc. NOTE:- The cable terminal ends for connection to switchgear at various requisite points shall be Al. Thimbles of dowel’s make and of appropriate size and connected by hydraulic crimp tool only. 10sqmm, 2 core, LT , 1.1 KV |
358 | P/I of earthing station for substation, LT panel, DG set and stabilizer comprising of company fabricated earthing electrode as per IS: 3043. The job includes Auguring of bore of required dia/depth for installation of electrode along with backfill compound mixed with soil and all other items required thereof for achieving the best result. The job includes connecting of electric gadgets through GI strip as per relevant standards. Safe earthing electrode size:80 mm dia , Length :2000 mm Back fill compound :30 kg |
359 | Providing, installation, testing and commissioning of area lighting 120 Watt LED (Street Light Type) on top of octagonal pole vide item No.36 Having following specs: Input: 90-240 V 50 Hz Power Factor: >0.9 Colour Temperature: 4K - 6.5K Beam Angle: 120° - 170° Lumens: >12000 Operating Temperature: -20°C to 60°C The LED is pressure die cast aluminum housing with power coated finish and having Ingress Protection up to IP-68. The LED is to be properly fitted on the arm of the pole and connected to the copper wire as directed. |
360 | Supply, installation, Testing & commissioning of 1000VA Full Sine wave power inverter (Make: Microtek/Luminous) including Providing / Installation of 12V, 180AH Tubular inverter Battery with trolley and cover. (Make: Amaron /Exide) with 2-core 6mm2 Cu wiring as per site requirement along with other accessories like SS-Combine (02 No’s), 3-pin plugs etc of reputed make for proper fitment and installation of the item. |
361 | Providing, laying & fixing with adhesive/bonding material of insulation rubber mats on the floor of the pump house, covering area around electro-mechanical machinery for safeguarding the life & limb of the workmen due to possible leakage of current & short circuit. The floor surface shall be made good & shall be free from dust, grease, foreign material & moisture free. The mats shall be as per IS 15652:2006 & shall have the following specifications: - Composition: Rubber (synthetic mats for electrical purpose) Thickness: - 2.5mm Size: - 1M wide. The rubber mats shall be accepted with manufacturers test certificate. |
362 | TOOL KIT For Maintenance: - The Tool Kit for maintenance shall comprise of the following and all the items as mentioned below shall be of : Providing of tool kit consists of following items Restspecification as per clause - 46 of SBD |
363 | a) Providing of good quality bedding for night stay/Shift consisting of: - i) Mattress with warm cover size 6"x3" (6Kg)- 02 No’s ii) Quilt with warm cover size 5"x8" (6Kg)- 02 No’s iii) Pillows with covers - 02 No’s iv) Single bed warm blankets with one sided Fur- 02 No’s The filling material for mattress, quilt and pillow shall be of good quality cotton b) The job also includes providing of pressure cooker 5ltr 02 No’s, Steel patila (utensil) 5ltrs 02 No’s, cooking heater 01 No., room heater 01 No., steel buckets 10 litre capacity 01 No., Plastic bucket 10 litre capacity with Mug 02 No’s each, steel glasses 06 No’s, steel Plates with large spoons and bowls 03 No’s each, Cup and Saucer set (01 No. Set) and, 5kg Gas cylinder with burner/ stove. All the utensils shall be of Prestige, Pigeon, Wonder chef, United, Futura make. The job also includes providing of thermo-cool 15’x12’ along with excel matting of 15’x12’ size. The job also includes providing of unbreakable Plastic Chair table set consisting of chairs 04 No’s, extra heavy Table 01 No. The job also includes providing of good quality safety Door locks (03 No’ |
364 | Providing of solar/ electrical lantern chargeable on both solar & electrical 220v supply. |
365 | Providing of bamboo ladders 18 feet long along with 15 feet long Link rods and HT Glove pair (01 No each) |
366 | Providing of 1 KW heat convector for operators for winter season. |
367 | P/Fof lighting points in 1.5 sq.mm multi strand PVC wire as conductor to be laid / carried in PVC Channel / conduit as per site requirement duly fiited with approperiate fasteners. the job includes providing and fittingof all the PVC bends , connectors etc and5 Amp. Switch fitted on common plate flushed with wallfor beter look andbutton / Angle Holders to be fittedon with LED blubs(energy saver)inside the pump house. |
368 | P/F of heating points in 2.5 Sq. mm multi stranded PVC conductor to be carried in PVC channel/conduit as per site requirement duly fiited with approperiate fasteners . the job includes providing and fitting ofall the PVCbends , connectors 16 Amp. Switch socket combine to be fiited flushed with wall |
369 | P/F of distribution board of SP & N (regal gray ) with 1 no. incoming and outgoing 16 way , fitted with MCB“C” Series6A- 12Nos. and 16 Amp- 4nos for heating points and 36 AMCB For mains. The job includes the cost of 4 Sq. mm multi stranded PVC conductor to be laid as service line for lighting system. |
370 | providing and fitting of 18"" sweep seiling fan of standard make including the cost of all cables , connections , , controlsystem along with the speed regulator with control switches for the power supply |
371 | Providing and fitting of 01 No. angle iron/sheet metal board duly painted showing various specifications of the mechanical and electrical equipments installed at site. |
372 | Removal of choked filter media from 5000 GPH pressure filter vessel. The job includes all loads and lifts, disposal of choked media to dumping site outside the premises of the plant within a lead of 5 km. The vessel needs to be cleaned properly and dried before laying of fresh media. |
373 | Providing and laying of filter media of specific size and grade to be laid in 5000/6000 GPH Pressure vessel duly washed, free from dust, dirt, loom and any other inorganic materialor suspension the job includes carriage of filtermedia from Ganderbalto site including allall loads and liftsrequired on the site condition. The media is to be lad in different layers of specific size and grade from bottom to top over the filter bed plate. The bottom layer is to be laid without tilling/damaging the pressure nozzles. |
374 | Providing and fitting of 12 mm dia. Fine threaded PVC nozzles auxiliary type to be fitted on filter bed plate of pressure vessel. |
375 | Providing and fitting of 29 inch dia. rubber washers/gaskets for manhole and inspection chamber and opening of pressure filter vessel. |
376 | Providing and fitting of 3”x5/8” nuts and bolts. |
377 | Providing and fitting of pressure gauges with adopters to replace damaged ones these pressure gauges should be in the range of 0-50 kgf/cm/sg of reputed make. |
378 | Providing, fabrication and fitting of welded MS wire mesh (0.50 sq. inch and 1.40mm wire dia. for Bird screening to the CGI Pressure Filter House. |
379 | Carriage of cement/steel/CGI sheet/GI pipes below 100mm dia and other heavy materials by mechanicaltransportincluding loading, unloadingand stacking (average distance -25Km) |
380 | 13.WSS Barsoo Old (Adv. Cost: Rs. 75,19,329/-) |
381 | Supply, Installation, Testing & Commissioning of Non-clog Pumping Unit as per IS 5600 at Raw Water Stage. PUMP: - Type of pump : Non–clog Open well Submersible Vertical Pump • Solid Handling Capacity: 20mm (Minimum) • Quality of water: Raw water to be handled MATERIAL OF CONSTRUCTION: • Pump Casing : Cast Iron • Impeller : Stainless Steel • Pump Shaft : Stainless Steel • Motor Body : Cast Iron • Sealing : Dual mech. seal Manufactures Test Certificate to be apended and completedetailed specifications as per cluase "2 "of of SBD. i.motor rating =7.5 HP |
382 | ii. motor rating =10 HP |
383 | Supply, Installation, Testing & Commissioning of Open Well Pumping Units as per IS 14220 at Filter Water Stage. Manufactures Test Certificate to be apended abd detailed specification as per cluase "4" of of SBD motor Rating = 15 HP |
384 | Supply, installation, testing and commissioning of Horizontalpumping unit as per IS 1520 with following specification:- Pump:- 1.Type :-Horizontal monoblock Manufactures Test Certificate to be apended and detailed specification as per cluase "5" of of SBD |
385 | Providing/supplying and fitting ofG.I flanged Rising Main at site. The Pipe shall be hot dip Galvanized, class-C confirming to IS 1239. The job includes providing and fitting of M.S Flanges conforming to BIS 6392/1997 Table 17 (Rating PN16). The flanges shall be double welded both from inside and outside of the pipe using standard electrode of reputed make. Flanges (as per IS 6392/1997 Table:17) Thickness shall conform to IS 6392 Part 1st Table-17. The flange welding shall be carried out in double layers using reputed make electrodes to form strong welding joint. Welding Electrode DC Arc Welding using welding electrode having diameter not less than 4mm. Nuts and Bolts Nuts and Bolts (conforming to IS:1363 Part 1st) Rubber Insertion Gaskets Rubber Insertion Gaskets (conforming to IS: 638/79) to be used between flanged joints. The rising main is to be laid as per the instructions of the engineer in charge and site requirement. Size : DN80 Class: C (Heavy) |
386 | Earth work in excavation by manual means in trenches for foundation, drains, pipes, cables (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and reaming of bottom lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed. (All kinds of soil 01 meter from cutting edge) |
387 | Filling available excavated earth in trenches, plinth, sides of foundation etc.in layers not exceeding 20 cm in depth, consolidating each deposited layer by reaming and watering , lead upto 50 m and lift upto 1.5m. |
388 | Providing and laying of stone soling including manual compaction |
389 | Centering and shuttering including strutting, propping etc. and removal of form work for Foundation, footings, bases for columns |
390 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering-all work upto plinth level with following mix: 1 : 2 : 4 mix (1 cement, 2 coarse sand, 4 graded stone aggregate 20mm nominal size) |
391 | 1 : 1.5 : 3 mix ( 1 cement, 1.5 coarse sand, 3 graded stone aggregate 20mm nominal size) |
392 | 1 : 4 : 8 mix (1 cement, 4 coarse sand, 8 graded stone aggregate 40mm nominal size) |
393 | Fabrication, providing and fitting of split type MS clamps10 mm thick, 2 ft long and 3 inch wide for lowering and holding of pumping unit fitted. The job includes the cost of required size of nuts and bolts. Size: 80mm |
394 | Fabrication, Providing and fitting of90-120 degree bend/elbowto be fabricated out ofG.I pipe, 1 m lengthand flanged on both ends ato make it leak proof. The flanges shall be M.S Flanges conforming to BIS 6392/1997 Table 17 (Rating PN16) and welded on both sides. The job includes nuts, bolts, gaskets etc as per site requirement. Size:DN 80 Class: C |
395 | Cutting of hot dip galvanized G.I,pipe across the section by dint of pipe cutter/ gas cutter. The job also includes Providing and welding of M.S flanges to the two ends of pipe. The Thickness of flange shall conform to IS 6392 Part 1st Table-17. The flange welding shall be carried out in double layers using Advani/Esab/L&T- SS Bond make electrodes to form strong welding joint by dint of DC arc welding. The job further includes Providing and Fitting of nuts and bolts (conforming to IS:1363 Part 1st) and Rubber Insertion Gaskets (conforming to IS: 638/79) to be used between flanged joints. The size of the pipe isDN 80 , Class-C |
396 | Fabrication, Providing and fitting of Y- junction having 1m length of each armto be fabricated out ofhot dip galvanized G.I, C-Class pipe . The job also includes Providing and welding of M.S flanges to the ends of each arm . the Thickness of flange shall conform to IS 6392 Part 1st Table-17. The flange welding shall be carried out in double layers using reputed make electrodes to form strong welding joint by dint of DC arc welding. The job further includes Providing and Fitting of nuts and bolts (conforming to IS:1363 Part 1st) and Rubber Insertion Gaskets (conforming to IS: 638/79) to be used between flanged joints. The size of the Y- junction is given below : size : DN 80 , Class - C |
397 | Fabrication, providing and fitting of washout Tee with arm length 1.2 feet each. The Tee shall be fabricated out of G.I pipe with M.S Flanges conforming to BIS 6392/1997 Table 17 (Rating PN16) fastened with weld joints on three ends. Size: 80mm Class: C class |
398 | Providing and fitting of, Ductile Iron double flanged, non-rising spindle soft seatedglandless gate/ sluice valves as per IS14846 for regulating the water supply outside the pumping units . The body and bonnent of the valve shall be of ductileiron, wedge with fully vulcanized EPDM rubber (Approved for drinking water) and NBR seal. The Gate/Sluice valve shall be compatible for buried applications and shall be safe to install in both horizontal and vertical positions It shall have electrostatic epoxy coating(approved for drinking water) both inside and outside of the valve. The valve shall be supplied along with hand wheel. Cost on account of Nuts, bolts, gaskets, etc required for the job is included in the scope of work. The job includes providing and fitting of 02 nos. M.S flanges perfectly adaptable to the inbuilt flanges of the valve which shall be fitted with rising main of the pumping unit at appropriate spots as per site requirement. Size: DN80 PN:1.6/16 |
399 | Providing and fitting ofDuctile Iron double flanged, Slanted seatswing check valve( NRV) as per IS 5312. The body shall be of ductile cast iron with fully encapsulated vulcanized EPDM rubber(Approved for drinking water). The valve shall be compatible for buried applications and shall be safe to install in both horizontal and vertical positions. It shall have electrostatic epoxy coating (approved for drinking water) both inside and outside of the valve. Cost on account of Nuts, bolts, gaskets, etc required for the job is included in the scope of work. The job includes providing and fitting of 02 nos. M.S flanges perfectly adaptable to the inbuilt flanges of the valve which shall be fitted with Rising main of the pumping unit at appropriate spots as per site requirement. Size: 80mm PN: 1.6/16 |
400 | Providing, fitting, testing and commissioning of DN 50 , PN 1.6/16ARV (Air Release valve ) as per IS 14845 to be fitted toG.Irising Main .. . the ARV Shall have the following specifications: - i. Valve type -single chamber, single orifice. ii. End connection-flanged ends to IS 1538 iii. Working temperature- 70oc to 550 c iv. Test pressure - body / seat 2.5 x PN v. Sealing ring -EPDM vi. Construction-ductile iron with stainless steelfloats vii. Coating -epoxy with corrosion resistance Besides the above works, The job also cost on account of P/F R.I gasket, nuts and bolts required for installation of ARV and arrangement of gas cutter/ welding set at site. |
401 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses, construction of lineretc. including cutting , hoisting , fixing in position and applying a priming coat of approved steel primer , including welding and bolted with special shaped washers etc. complete Electric resistance or induction butt welded tubes |
402 | Fabrication of platform to bear the load of pumping unit, column pipes etc by way of providing and fitting of Steel work welded in built up sections/framed work , including cutting , hoisting , fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. The job involves following steel details: i. In stringers, treads, landings etc of stair cases including use of chequered plate wherever required, all complete |
403 | Fabrication of gantry mechanism/CGI Shed / plate form by way of providing Structural steel in built up sections , trusses and framed work, including cutting , hoisting , fixing in position and applying a priming coat of approved steel primer all complete welded |
404 | Providing, installation andtestingof manual type triple spur gearchain pulley block along with monorail gearedtravelling trolleyhaving following features. Gears:- The hoist shall have precision machine case Hardened alloy steel gear mounted on bearings and housed in a dust proof gear box. The lubrication of gears should be of high viscosity and temperature for longer life of gears. Load Chain:-The load chain be made of high tensile alloy steel having wear resistance and greatest mobility. The chain should be accurately collaborated, tested and have adequate in built factor of safety for safer operation. Load chain wheel:- the load chain well should be double ball bearing supported andSpecially designed, perfectly machined wheel providing correct grip of load chaintomakes the hoist most safe and reliable against any failure. The main specifications of C.P Block are given below : Make = Reputed make Capacity=3ton No. Of load chain falls = 2 or above Min. Height of lift = 6 M |
405 | Supply, Installation, Testing and commissioning of Polymeric Gang operated Air break switch, outdoor type, triple pole, suitable for vertical installation, single break provided with locking arrangement at both ON and OFF position consisting ofHT post double insulator, copper or copper alloy high pressure heavy contact assembly, rod with bearings , operating handle and 2 length of 32mm dia. GI pipe conforming to IS 1818 1961, 06 No. of insulators, rated voltage 11KV 200A complete as per IS specs. |
406 | Supply and fitting of 11 KV polymeric composite pin insulator 12 KV, 5KN, Lighting impulse 75KV Positive, and 80 KV Negative , creepagedistance 320 mm |
407 | P/F of Galvanized nuts, bolts of various sizes as per site requirement. |
408 | Providing and fitting of ACSR as per IS 398 (part-2) 1996 for 50 sq.mmACSR (Galvanised steel reinforced) for fitment of various accessories |
409 | Fabrication, Providing and fitting ofModularmotor control panel of appropriate size fabricated out of 14 SWG sheet having required openings/vents and protection Class : IP-55 & fitted with accessories as under: a) Busbar Chamber: MU-G 7.5 or MU-G 10Rest complete specifications and quantity as per Clause- 43 - B Of SBD |
410 | Fabrication, Providing and fitting ofModularmotor control panel of appropriate size fabricated out of 14 SWG sheet having required openings/vents and protection Class : IP-55 & fitted with accessories as under: MU-G 15 rest specifications as per Cluase- 43- C of SBD |
411 | Fabrication, Providing and fitting ofModularmotor control panel of appropriate size fabricated out of 14 SWG sheet having required openings/vents and protection Class : IP-55 & fitted with accessories as under: rest specifications as per Cluase- 43- D OF SBD |
412 | Providing, fitting, testing and commissioning ofvoltage stabilizeras per specifications below: Type of voltage controller: Manually operated copper wound, 3-phase, AC power supply multi step. Type of Regulator: Double plate type with electrolytic copper contacts. Input voltage : 250-400 volts.(3 phase) Output voltage : 400 ±10% volts. Frequency : 50±3 C/S. rest Specifications as per cluase-44 of SBD Rating:30KVA |
413 | Providing and fitting of 3-Core flatsubmersible copper cable conforming to IS: 694 (Part 1st) – 1964 & IS: 694 (Part 2nd) - 1964 for Submersible Pumping Unit and other electrical Equipments . The cable connections terminal shall be fitted with copper thimbles of required size. Size: 16 Sq.mm |
414 | Size: 6 Sq.mm |
415 | Providing and Fitting of 3 /3.5/2-Core, XLPE Armoured Aluminium Cable conforming to IS: 7089 part 1st as service line from the HT transformer to control panel including necessary thimbling, crimping, taping etc. NOTE:- The cable terminal ends for connection to switchgear at various requisite points shall be Al. Thimbles of dowel’s make and of appropriate size and connected by hydraulic crimp tool only. i) 50 sqmm, 3.5 core, LT, 1.1 KV |
416 | ii) 10 sqmm, 2 core, LT, 1.1 KV |
417 | P/I of earthing station for substation, LT panel, DG set and stabilizer comprising of company fabricated earthing electrode as per IS: 3043. The job includes Auguring of bore of required dia/depth for installation of electrode along with backfill compound mixed with soil and all other items required thereof for achieving the best result. The job includes connecting of electric gadgets through GI strip as per relevant standards. Safe earthing electrode size:80 mm dia , Length :2000 mm Back fill compound :30 kg |
418 | Supply, installation of 6 kg co2 type fire extinguisher manufactured as per IS:15683 OF 2006 with IS mark and comply with DGMS(Approval) . The co2 extinguisher should be suitable for class B & C fire and also for fire involving electrical equipments. the cylinder used for fire extinguisher shall be approved by protroleum andexplosive safety organization(PESO) as per gas cylinder rules 2004 and as per IS: 7285 of 2004. The body should be made of seamless steel (manganese) confirming to IS:7285 with IS mark and should be provided with squeeze grip nozzle and should be filled with co2 confirming to IS : 15222 of 2002 with certificate.The extinguisher shall be provided with manufactures test certificate and hydraulic test certificate by BIS from PESO. |
419 | Illumination of Premises: Providing and erection of 9 Mtr long Hot Dip Galvanized octagonal pole (single Section) with bottom 150mm, top 75mm wide, thickness 3mm with 70 Microns Zinc coating having inside arrangement for providing of power connection along with following items. 1) 3 Way Terminal Connector 20 Amp. 2) 3 No MCB 8 Amp. The job includes fabrication, providing and fitting of three arm GI structure at the top having 120° angle between arms and each arm having 15° inclination with respect to horizontal plane. Each arm should be of 2’ length and size and shape appropriate as per requirement of the luminary. The job also includes providing and fitting of required length of flexible multi strand 2 mm copper wire from each terminal connector to each holding arm. The pole is to be mounted on 1:2:4 Cement concreting of size not less than 2’x2’x6” ( cost of concreting not included in the job) using 04 No anchor bolts of required size not less than 7” in length. The complete job includes earthing in GI Electrode as per relevant IS Code. |
420 | Providing, installation, testing and commissioning of area lighting 120 Watt LED (Street Light Type) on top of octagonal pole vide item No.36 Having following specs: Input: 90-240 V 50 Hz Power Factor: >0.9 Colour Temperature: 4K - 6.5K Beam Angle: 120° - 170° Lumens: >12000 Operating Temperature: -20°C to 60°C The LED is pressure die cast aluminum housing with power coated finish and having Ingress Protection up to IP-68. The LED is to be properly fitted on the arm of the pole and connected to the copper wire as directed. |
421 | Providing, Installation and testing of 2KVA fully automatic voltage stabilizer with input voltage 70-240 V and output 220 V. The stabilizer shall be installed and connected to the electric circuit as per location provided by site incharge. |
422 | Supply, installation, Testing & commissioning of 1000VA Full Sine wave power inverter (Make: Microtek/Luminous) including Providing / Installation of 12V, 180AH Tubular inverter Battery with trolley and cover. (Make: Amaron /Exide) with 2-core 6mm2 Cu wiring as per site requirement along with other accessories like SS-Combine (02 No’s), 3-pin plugs etc of reputed make for proper fitment and installation of the item. |
423 | Providing, laying & fixing with adhesive/bonding material of insulation rubber mats on the floor of the pump house, covering area around electro-mechanical machinery for safeguarding the life & limb of the workmen due to possible leakage of current & short circuit. The floor surface shall be made good & shall be free from dust, grease, foreign material & moisture free. The mats shall be as per IS 15652:2006 & shall have the following specifications: - Composition: Rubber (synthetic mats for electrical purpose) Thickness: - 2.5mm Size: - 1M wide. The rubber mats shall be accepted with manufacturers test certificate. |
424 | TOOL KIT For Maintenance: - The Tool Kit for maintenance shall comprise of the following and all the items as mentioned below shall be of : Providing of tool kit consists of following items i. Double ended Spanner(Chrome plated)of size in mm 6/7,8/9,10/11,12/13,14/15,16/17,18/19,20/22,21/23,24/26,25/28, 24/27, 30/32 each – 02 no.ii. double ended Ring spannerschrome platedof size inmm 6/7,8/9,10/11,12/13,14/15,16/17,18/19,20/22,21/23,24/26,25/28, 24/27, 30/32 each – 02 no. iii. Allen key set black finish of size in mm 1.5, 2, 2.5, 3, 4,5,6,8,10 each – 2 NO.iv. Combination Pliersinsulated with thick C.A sleeve; size in mm 165, 210, 255each – 02 No.v. Long nose plier insulated with thick C.A sleeve; size in mm 165, 205each – 02 No.vi. Side cutting plier insulated with thick C.A sleeve; size in mm 165, 205make – tapariaeach – 02 No.vii. Insulated screw Drivers Blade length in mmBlade dia. in mmTip dimensions in mm Quantity 50 3 1.6 x 0.4 0275 3 1.6 x0.4 02 100 3 3 x 0.4 02 125 3.5 3.5 x 0.502 150 3.5 3.5 x 0.5 02 200 4 4 x 0.6 02 300 5 5 x 0.8 02 viii. Hammer with handle weight – 110 mg , 340 gm , 600 gm –each – 1No. . ix. Heavy duty pipe Wrench length in mm- 200, 300, 600 each – 01 No.. x. Electric Multimeter=1Noxi. Digital multimeter – 1No.(Fluke/Meco/scemens/Mastech) xii. Digital Clamp testercapable to measure up to 400A-1 No.xiii. Hack saw framewith hack saw blade – 01 no. xiv. S-16MXL, S- 16 H X L Socket Set( 19 sockets + 6 Accessories) – 01 No. |
425 | Fabricationof6’ x 6’ angle iron bed by way of providingand fitting of Structural steel in built up sections , trusses and framed work, including cutting , hoisting , fixing in position and applying a priming coat of approved steel primer all complete welded |
426 | Providing and fitting of 19 mm thick multilayered ply sheet of size 6 x 3 feet , 2 nos including cutting , fixingall complete including painting of the play sheet by one coat of primer and two coats of enamel paint |
427 | a) Providing of good quality bedding for night stay/Shift consisting of: - i) Mattress with warm cover size 6"x3" (6Kg)- 02 No’s ii) Quilt with warm cover size 5"x8" (6Kg)- 02 No’s iii) Pillows with covers - 02 No’s iv) Single bed warm blankets with one sided Fur- 02 No’s The filling material for mattress, quilt and pillow shall be of good quality cotton b) The job also includes providing of pressure cooker 5ltr 02 No’s, Steel patila( utensil) 5ltrs 02 No’s, cooking heater 01 No., room heater 01 No., steel buckets 10 litre capacity 01 No., Plastic bucket 10 litre capacity with Mug 02 No’s each, steel glasses 06 No’s, steel Plates with large spoons and bowls 03 No’s each, Cup and Saucer set (01 No. Set) and, 5kg Gas cylinder with burner/ stove. All the utensils shall be of Prestige, Pigeon, Wonder chef, United, Futura make. The job also includes providing of thermo-cool 15’x12’ along with excel matting of 15’x12’ size. The job also includes providing of unbreakable Plastic Chair table set consisting of chairs 04 No’s, extra heavy Table 01 No. The job also includes providing of good quality safety Door locks (03 No’ |
428 | Providing of solar/ electrical lantern chargeable on both solar & electrical 220v supply. |
429 | Providing of bamboo ladders 18 feet long along with 15 feet long Link rods and HT Glove pair (01 No each) |
430 | Providing of 1 KW heat convector for operators for winter season. |
431 | Providing and fitting of 01 No. LED (scroll type) sign board fabricated out of stainless steel and metal showing the names of water supply scheme and the Department. Size:6’×1’6” |
432 | P/Fof lighting points in 1.5 sq.mm multi strand PVC wire as conductor to be laid / carried in PVC Channel/conduit as per site requirement duly fiited with approperiate fasteners, the job includes providing and fittingof all the PVC bends, connectors etc and5 Amp. Switch fitted on common plate flushed with wallfor beter look andbutton / Angle Holders to be fittedon with LED blubs (energy saver) inside the pump house. |
433 | P/F of heating points in 2.5 Sq. mm multi stranded PVC conductor to be carried in PVC channel/conduit as per site requirement duly fiited with approperiate fasteners . the job includes providing and fitting ofall the PVCbends, connectors 16 Amp. Switch socket combine to be fiited flushed with wall |
434 | P/F of distribution board of SP & N (regal gray ) with 1 no. incoming and outgoing 16 way, fitted with MCB“C” Series6A- 12Nos. and 16 Amp- 4nos for heating points and 36 AMCB For mains. The job includes the cost of 4 Sq. mm multi stranded PVC conductor to be laid as service line for lighting system. |
435 | Providing and fitting of 18"" sweep seiling fan of standard make including the cost of all cables , connections , , controlsystem along with the speed regulator with control switches for the power supply |
436 | Providing and fitting of 01 No. angle iron/sheet metal board duly painted showing various specifications of the mechanical and electrical equipments installed at site. |
437 | Providing, installation, Testing & commissioning of 415 ±10%V (output), 3 phase Diesel Generator set as per IS 8528 (2018) and ISO 3046 (2002) for engine and IEC/IS 60034-1 for alternator suitably assembled and fitted in a pollution free acoustic enclosure / canopy of required size as per Ministry of Environment protection rule 1986 read with latest amendments. The DG Set is required to be fitted and tested on load at siteThe D.G Set shall have the following technical specification. Besides the above works the D.G set shall be provided with 12 V, 150 AH Lead acid battery of reputed make fitted inside the D.G set Canapy along with necessary accessories and battery charger of required capacity. The job also includes the cost on account of HSD and skilled operator required for operation of D.G set for a period of 10 hours continuously during its testing and commissioning of D.G set at site. the capacity of the D.G set is given below: Rating:40KVA , Air Cooled. |
438 | Providing, installation, Testing & commissioning of 415 ±10%V (output), 3 phase Diesel Generator set as per IS 8528 (2018) and ISO 3046 (2002) for engine and IEC/IS 60034-1 for alternator suitably assembled and fitted in a pollution free acoustic enclosure / canopy of required size as per Ministry of Environment protection rule 1986 read with latest amendments. The DG Set is required to be fitted and tested on load at siteThe D.G Set shall have the following technical specification. Besides the above works the D.G set shall be provided with 12 V, 150 AH Lead acid battery of reputed make fitted inside the D.G set Canapy along with necessary accessories and battery charger of required capacity. The job also includes the cost on account of HSD and skilled operator required for operation of D.G set for a period of 10 hours continuously during its testing and commissioning of D.G set at site. the capacity of the D.G set is given below: Rating:30KVA , Air Cooled. |
439 | Providing, Installation, Testing & Commissioning of complete switchgear unit for protection of D.G Setconsisting of 200A MCCB 3- pole , 415 V, 50 KV breaking capacity housed properly in cubical enclosure made upof M.S SWG – 16 sheet steel (outdoor type)duly powder paintedwith anti corrosive paint comprising of three compartments for incoming / out going circuits and MCCB. The panel should have adequate double locking Arrangement with Cu-. Bus Bar 12x40 mm with Bakelite insulation and LT Arrangement selector switches, phase indicators. The equipment should be installed at appropriate height in a stand consisting of 50 x 50 x 6 mm angle grouted in ground with appropriate cement bottoming as per the IS standard.The work is to executed near D.G SET at site |
440 | Providing corrugated G.S Sheet roofing including vertical/ curved surface fixed with polymer coated J or L Hooks , bolts and nuts 8 mm dia. diameter with bitumen and G.I limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete ( upto any pitch in horizontal /vertical or curved surface) excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 0.50mm thick with zinc coating not less than 275 gram/m2 |
441 | Providing, cutting, fittingand welding Green PVC Coated welded wire fencewith Squaremesh -4and wire diameter 1.5 mmto be fitted onall openverticalsides of the D.G Set shed. The job includes cutting, welding, hoisting etc as per site requirement. |
442 | Providing ridges or hips of width 60 cm overall with plain G.S sheets fixed with polymer coated J- Or L- hooks , Bolts and nuts 8 mm dia. G.I limpet and bitumen washers complete 0.63 mm thick with zinc coating not less than 275 gram/sq.m |
443 | Removal of choked filter media from 5000 GPH pressure filter vessel. The job includes all loads and lifts, disposal of choked media to dumping site outside the premises of the plant within a lead of 5 km. The vessel needs to be cleaned properly and dried before laying of fresh media. |
444 | Providing and laying of filter media of specific size and grade to be laid in 5000/6000 GPH Pressure vesselduly washed, free from dust ,dirt ,loom and any other inorganic materialor suspension .the job includes carriage of filtermedia from Ganderbalto site including allall loads and liftsrequired on the site condition. The media is to be lad in different layers of specific size and grade from bottom to top over the filter bed plate. The bottom layer is to be laid without tilling/damaging the pressure nozzles. |
445 | Providing and fitting of 12 mm dia. Fine threaded PVC nozzles auxiliary type to be fitted on filter bed plate of pressure vessel. |
446 | Providing and fitting of 29 inch. dia. rubber washers /gaskets for manhole and inspection chamber and opening of pressure filter vessel. |
447 | Providing and fitting of 3”x5/8” nuts and bolts. |
448 | Providing and fitting of pressure gauges with adopters to replace damaged ones .the pressure gauges should be in the range of 0-50 kgf/cm/sg of reputed make. |
449 | Replacement of 80 mm dia. cast iron diaphragm valves by way of inducing fresh DI Gate valve /Butter flyvalve with pressure rating of PN16. The job includes providing and fitting of nuts and bolts and washers and necessary mechanical works |
450 | P/F ofDN 65Butterfly Valves. The job includes providing and fitting of nuts and bolts and washers with allied mechanical works |
451 | Replacement of agitator in alum solution holding tank fabricated out of wetted parts in stainless steel .speed 20-30 rpm .intermediate bearing paddle type twin blades free standing type. |
452 | Providing & Fitting of Dozing pumps to doze required quantity of alum/Chlorine in the system. The capacity of the dozing units shall be 0-12 LPH capacity. Dozing pups shall be provided with all required accessories including 200 ltrs. PVC tanks and cable for connection. Each pump shall be provided with 20 mtrs. cable as per required specification. |
453 | Providing & Fitting of Dozing pumps to doze required quantity of alum/Chlorine in the system. The capacity of the dozing units shall be 12-20 LPH capacity. Dozing pups shall be provided with all required accessories including 200 ltrs. PVC tanks and cable for connection. Each pump shall be provided with 20 mtrs. cable as per required specification. |
454 | Providing and installation of 300 ltrs HPPE Tank required for alum solution |
455 | Providing and installation of 100 ltrs HPPE Tank required for chlorine solution |
456 | Painting with synthetic enamel paint two or more coats of approved brand and bar pressure clarifier pressure filter vessel, fittings and complete piping after cleaning of dirt by kerosene oil and application of steel primer of specific grade. |
457 | Providing, fabrication and fitting of welded MS wire mesh (0.50 sq. inch and 1.40mm wire dia.) for Bird screening to the CGI Pressure Filter House. |
458 | Carriage of sand, stone aggregate by mechanical transportincluding loading, unloadingand stacking (average distance-5km) |
459 | Carriage of soling stone by mechanical transportincluding loading, unloadingand stacking (average distance-5km) |
460 | Carriage of cement/steel/CGI sheet/GI pipes below 100mm dia and other heavy materials by mechanicaltransportincluding loading, unloadingand stacking (average distance -25Km) |
461 | 14.WSS Ratnipora/Kharbatpora (Adv. Cost: Rs. 20,50,000/-) |
462 | Iron Removal Plant Design, Supply, installation & commissioning including 5 years operation & maintenance for 22500 LPH Iron Removal Plant with all allied works at Water Supply Scheme Kherbatpora with following general specifications here as under Source-Tube well Iron content in mg / litre – 0.5. Phosphate: 1.8mg/l Filtration Capacity – 22500 Litres per hour Quantity of water to be filtrated / day – 360000 Litres Operational Hours – 16 The plant is to be erected on the cerementconcrete plant from with3ft passage around the plant for easy movement & the plant from shell be above ground within the premises of tube well above maintain H.F.L in 1:2: 3: C.C mix & allied civil work & painting work & in full. (as per Annexure of ENIT Tender Notice) Specifications as per SBD 105 |
463 | 15.WSS Achan Astanpora (Adv. Cost: Rs. 3,41,524/-) |
464 | Fabrication, providing, fitting and lowering B Class column pipe conforming to IS: 1239 of length 10 Rft into the 200/ 250/300 mm casing dia. production well upto the desired depth ; The job includes Providing and welding of flanges conforming toIS: 6392, Table-17 and PN 16 to these pipes and welding of flanges in two layers to make the flanged joint strong and leak proof. The pipe of 10 ft length is to be weld on both sides with flanges using welding rod of reputed make. The job includes all types of skilled labours, arrangement of power supply/ diesel Generator set etc required for the job including P/F of suitable size nuts bolts and R.I Gasket in the flanged joints of column pipes. The job further includes cutting of 2 no. rectangular cable slots in each flange.The dia of pipe is 65 MM. |
465 | Providing/supplying and fitting of G.I flanged Rising Main at site. The Pipe shall be hot dip Galvanized, class Bof65mm confirming to IS 1239. The job includes providing and fitting of M.S Flanges conforming to BIS 6392/1997 Table 17 (Rating PN16). The flanges shall be double welded both from inside and outside of the pipe using standard electrode of reputed make. Flanges (as per IS 6392/1997 Table:17) Thickness shall conform to IS 6392 Part 1st Table-17. The flange welding shall be carried out in double layers using reputed make electrodes to form strong welding joint. Welding Electrode DC Arc Welding using welding electrode having diameter not less than 4mm. Nuts and Bolts Nuts and Bolts (conforming to IS:1363 Part 1st) Rubber Insertion Gaskets Rubber Insertion Gaskets (conforming to IS: 638/79) to be used between flanged joints. |
466 | Fabrication, providing and fitting of washout Tee with each arm one feet long shall be fabricated out of 65mm dia. G.I C-class pipe with 16mm thick flanges fastened with weld joints on three ends. |
467 | Providing and fitting of, PN 1.6/16 Ductile Iron double flanged, non-rising spindle soft seated glandless gate/ sluice valves as per IS14846 for regulating the water supply outside the pumping units. The body and bonnent of the valve shall be of ductileiron, wedge with fully vulcanized EPDM rubber(Approved for drinking water) and NBR seal. The Gate/Sluice valve shall be compatible for buried applications and shall be safe to install in both horizontal and vertical positions It shall have electrostatic epoxy coating(approved for drinking water) both inside and outside of the valve. The valve shall be supplied along with hand wheel. Cost on account of Nuts, bolts, gaskets, etc required for the job is included in the scope of work. The job includes providing and fitting of 02 nos. M.S flanges perfectly adaptable to the inbuilt flanges of the valve which shall be fitted with rising main of the pumping unit at appropriate spots as per site requirement. The job includes the cost on account of P/F of nuts, bolts and gasket required for the job. a) size 65 MM |
468 | Providing and fitting ofDN 65 mm PN 1.6/16 Ductile Iron double flanged, Slanted seat swing check valve( NRV) as per IS 5312. The body shall be of ductile cast iron with fully encapsulated vulcanized EPDM rubber(Approved for drinking water). The valve shall be compatible for buried applications and shall be safe to install in both horizontal and vertical positions. It shall have electrostatic epoxy coating (approved for drinking water) both inside and outside of the valve. Cost on account of Nuts, bolts, gaskets, etc required for the job is included in the scope of work. The job includes providing and fitting of 02 nos. M.S flanges perfectly adaptable to the inbuilt flanges of the valve which shall be fitted with Rising main of the pumping unit at appropriate spots as per site requirement. The job includes the cost on account of P/F of nuts, bolts and gasket required for the job. a) size 65 MM |
469 | Fabrication, Providing and fitting of65 mm dia 90-120 degree bend/elbowto be fabricated out ofClassB GI pipe, 1 m lengthand flanged on both ends ato make it leak proof. The flanges shall be M.S Flanges conforming to BIS 6392/1997 Table 17 (Rating PN16) and welded on both sides. The job includes nuts, bolts, gaskets etc as per site requirement. |
470 | Fabrication, providing and fitting of split type MS clamps10 mm thick, 2 ft long and 3 inch wide for lowering and holding of pumping unit fitted. The job includes the cost of required size of nuts and bolts. |
471 | Fabrication of gravel Hooper for proper feeding of gravels to the borewell andplatform to bear the load of pumping unit, column pipes etc by way of providing and fitting of Steel work welded in built up sections/framed work , including cutting , hoisting , fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. The job involves following steel details: i. In stringers , treads , landings etc of stair cases including use of chequered plate wherever required , all complete |
472 | Providing and fitting ofM.S 4 inch hinges -6 no and M.S handle heavy -8no., Anchor bolts with nuts (M16) of 0.3 m long= 04 No. Metallic strip (350mm×50mm×3mm) = 02 No. |
473 | Supply, Installation, Testing and commissioning of Polymeric Gang operated Air break switch, outdoor type, triple pole, suitable for vertical installation, single break provided with locking arrangement at both ON and OFF position consisting ofHT post double insulator, copper or copper alloy high pressure heavy contact assembly, rod with bearings , operating handle and 2 length of 32mm dia. GI pipe conforming to IS 1818 1961, 06 No. of insulators, rated voltage 11KV 200A complete as per IS specs. |
474 | Supply, Installation and Testing of 35 Sq mm XLPE Aluminum H.Tcable (ABC type ) of 11 KV grade with following specs. Size (cross sectional area in sq mm) = 3×35 Phases:Red, Yellow, Blue |
475 | Providing/Fitting of Suspension/Tention clamp with eye hook |
476 | Providing and fitting of 3-Core flat 10 square mm submersible copper cable conforming to IS: 694 (Part 1st) – 1964 & IS: 694 (Part 2nd) - 1964 for Submersible Pumping Unit and other electrical Equipments . The cable connections terminal shall be fitted with copper thimbles of required size. : |
477 | P/F of 11 KV cable termination kit for connecting 35 Sq mm XLPE cable (ABC type) with the existing HT line near tapping point and HT transformer. |
478 | Providing and Fitting of 3.5-Core, XLPE, 1.1KV and 11KV grade50 square mm Armoured Aluminium Cable of various sizes conforming to IS: 7098 part 1st as service line from the HT transformer to control panel including necessary thimbling, crimping, taping etc. |
479 | Providing and fitting of 16mm square single core copper cable for intwrconnecting various electrical gadets as per IS 694: 2010 along with thimbling as per requirement. |
480 | Fabricationof6’ x 6’ angle iron bed by way of providingand fitting of Structural steel in built up sections , trusses and framed work, including cutting , hoisting , fixing in position and applying a priming coat of approved steel primer all complete welded |
481 | Providing and fitting of 19 mm thick multilayered ply sheet of size 6 x 3 feet , 2 nos including cutting , fixingall complete including painting of the play sheet by one coat of primer and two coats of enamel paint |
482 | a) Providing of good quality bedding for night stay/Shift consisting of: - i) Mattress with warm cover size 6"x3" (6Kg)- 02 No’s ii) Quilt with warm cover size 5"x8" (6Kg)- 02 No’s iii) Pillows with covers - 02 No’s iv) Single bed warm blankets with one sided Fur- 02 No’s The filling material for mattress, quilt and pillow shall be of good quality cotton b) The job also includes providing of pressure cooker 5ltr 02 No’s, Steel patila( utensil) 5ltrs 02 No’s, cooking heater 01 No., room heater 01 No., steel buckets 10 litre capacity 01 No., Plastic bucket 10 litre capacity with Mug 02 No’s each, steel glasses 06 No’s, steel Plates with large spoons and bowls 03 No’s each, Cup and Saucer set (01 No. Set) and, 5kg Gas cylinder with burner/ stove. All the utensils shall be of Prestige, Pigeon, Wonder chef, United, Futura make. The job also includes providing of thermo-cool 15’x12’ along with excel matting of 15’x12’ size. The job also includes providing of unbreakable Plastic Chair table set consisting of chairs 04 No’s, extra heavy Table 01 No. of Samruddhi/ Neel kamal/Supreme /Anmol Make. The job also includes providing of good quality safety Door locks (03 No’s) of Godrej, Link locks, Thapar make. |
483 | Providing of solar/ electrical lantern chargeable on both solar & electrical 220v supply. |
484 | Providing of 1 KW heat convector for operators for winter season. |
485 | 16.WSS Reshipora Dogripora (Adv. Cost: Rs. 1,74,612/-) |
486 | Fabrication, Providing and fitting ofModularmotor control panel of appropriate size fabricated out of 14 SWG sheet having required openings/vents and protection Class : IP-55 & fitted with accessories as under: a) Busbar Chamber: 100 Ampres b) Main Circuit Breaker (Incomer MCCB): Qty:- =02 No. Current Rating = 160 Amp.4 Pole 50KA c) Change over Switch: Qty.= 01 No.Rating =100 Ampere d) Motor Back-up Protection MCCB: Qnty = 2 No’s Current Rating= 100 A 3 Pole 36 KA e) Submersible Motor starter: Fully automatic submersible motor starters. Rating = 20HP (MUG 20 H) Power Specs =3 ?, 415 + 15% V, 50 + 3 % Hz. Relay range= 28-42 A. Protection = Under voltage/ over Voltage Qty = 02 No’s f) Auxiliary MCCB for Heating/Lighting: Circuit Breaker = MCCB (Outgoing) Qty.= 1 No.Current Rating= 63 Amp. Rest of the specicifications are as per clause-43 d ofTechnical annexure of SBD |
487 | 17.WSS Kakapora Old (Adv. Cost: Rs. 24,85,591/-) |
488 | Providing, Laying, Fitting, Testing & Commissioning of 200 mm ND, 6.0 mm Thick beveled type M S pipe to replace the damaged rising main at Water Supply Scheme Kakapora Nehama with following specifications:- Nominal Dia200mm Wall Thickness6.0 mm Length of each pipe6.09 meters Quantity of MS for manufacturing of pipe as per BIS 226Type of welding ERW/EFW Grade of steel Fe-410 Working pressure20 kgf CoatingTwo coats of Black Bituminous paint. Manufacturing of pipeAs per BIS 3589. The job includes Fabrication of Off sets, wedges, bends, dismantling joints by way of cutting/ welding/ grinding as per contour for laying route of rising main. The job also includes Fabrication, Providing and welding of the 22mm thick ND 200mm MS Flanges/tabular Flanges (minimum 8 holes) fabricated out of 22mm thick plate for fitment of new pipe with the existing one as per site requirement. |
489 | Earth work in excavation by manual means in trenches for foundation, drains, pipes, cables (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and reaming of bottom lift up to 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed.all kinds of soil. |
490 | Filling available excavated earth in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by reaming and watering, lead upto 50 m and lift up to 1.5m. |
491 | Providing, Laying, Fitting,Testing & Commissioning of 150 mm ND, 6.0 mm Thick beveled type M S pipe to replace the damaged rising main at Water Supply Scheme Wanpora with following specifications:- Nominal Dia150mm Wall Thickness 6.0 mm Length of each pipe6.09 meters Quantity of MS for manufacturing of pipe as per BIS 226Type of welding ERW/EFW Grade of steel Fe-410 Working pressure20 kgf CoatingTwo coats of Black Bituminous paint. Manufacturing of pipeAs per BIS 3589. The job includes Fabrication of Off sets, wedges, bends, dismantling joints by way of cutting/ welding/ grinding as per contour for laying route of rising main. The job also includes Fabrication, Providing and welding of the 22mm thick ND 150mm MS Flanges/tabular Flanges (minimum 8 holes) fabricated out of 22mm thick plate for fitment of new pipe with the existing one as per site requirement. |
492 | Earth work in excavation by manual means in trenches for foundation, drains, pipes, cables (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and reaming of bottom lift up to 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed.all kinds of soil. |
493 | Filling available excavated earth in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by reaming and watering, lead upto 50 m and lift up to 1.5m. |
494 | Providing, fitting, testing and commissioning of 150 kvavoltage stabilizeras per specifications below: Type of voltage controller: Manually operated copper wound, 3-phase, AC power supply multi step. Type of Regulator: Double plate type with electrolytic copper contacts. Input voltage : 175-400 volts.(3 phase) Output voltage : 400 ±10% volts. Frequency : 50±3 C/S. Windings : Electrolytic grade copper of adequate section, vacuum impregnated andOven-dried. The voltage Stabilizer shall be accepted with manufacturers dully stamped test certificate and shall have name plate with specifications. REST OF SPECIFICATION AS PER CLAUSE 44 OF SBD |
495 | Providing, fitting , testing and commissioning of 50mm diaARV (Air Release valve ) as per IS 14845 to be fitted toG.Irising Main .. . the ARV Shall have the following specifications: - i. Valve type -single chamber, single orifice. ii. End connection-flanged ends to IS 1538 iii. Working temperature- 70oc to 550 c iv. Test pressure - body / seat 2.5 x PN v. Sealing ring -EPDM vi. Construction-ductile iron with stainless steelfloats vii. Coating -epoxy with corrosion resistance Besides the above works, The job also cost on account of P/F R.I gasket, nuts and bolts required for installation of ARV and arrangement of gas cutter/ welding set at site. |
496 | Providing and Fitting of 3.5-Core, XLPE, 1.1KVgrade 95 square mm Armored Aluminum Cable of various sizes conforming to IS: 7098 part 1st as service line from the HT transformer to control panel including necessary thimbling, crimping, taping etc. |
497 | Providing and fitting of 95 mm square single core copper cable for interconnecting various electrical gadgets as per IS 694: 2010 along with thimbling as per requirement. |
498 | Providing, installation, testing and commissioning of area lighting 120 Watt LED (Street Light Type) on top of octagonal pole vide item No.36 Having following specs: Input: 90-240 V 50 Hz Power Factor: >0.9 Colour Temperature: 4K - 6.5K Beam Angle: 120° - 170° Lumens: >12000 Operating Temperature: -20°C to 60°C The LED is pressure die cast aluminum housing with power coated finish and having Ingress Protection up to IP-68. The LED is properly fitted on the arm of the pole and connected to the copper wire as provided in the pole . |
499 | Providing Laying and connection of 2Cx10 mm² XLPE Aluminum Armored Cable from thepole to the MCB. The job includes underground laying or overhanging along with thimbling as per requirement and directions of the site in-charge. |
500 | 18.WSS Kumar Mohalla Wachi (Adv. Cost: Rs. 54,22,490/-) |
501 | Iron Removal Plant: Design, Supply, installation testing & commissioning including 5 years operation & maintenance of Iron Removal Plant with all allied works confirming to relevant BIS/IS code. The job shall include cost of all necessary allied and required items connections, valves, electromechanical work, pipe network including civil works as per requirement of site. The agency shall have to submit detailed design/ constructions and shop drawings for approval to the department before execution of works. All the equipment and item installed shall be from reputed and standard manufacturers, suppliers with proven track records approved by required technical data sheets, certificates from authorities and third-party inspections report before dispatch and installation. The quantity of water to be treated is Minimum 6.30litres per second (LPS). The iron content in raw water is 5.0 mg/L ,however, the agency has to conduct a fresh physio-chemical analysis of water sample of production tube well before execution of works. The iron removal plant should remove Iron either below orup toWHO standards (= 0.3ppm). The treated water from plant should be as per IS 10500/2012 norms. Specifications as per SBD 106 |
502 | Cost on account of 05 year operation & maintenance of plant involving engagement of sufficient No. (minimum three) of skilled / trained person in the said field, who shall be responsible for exclusivelyoperating and maintaining the plantfor first three months and subsequently engagement of at least one number of skilled labour for the next six monthsand subsequent yearly inspections by experts besides imparting training to the staff to be posted by the department at the said plant and the contractor shall comply with the portions of all labor laws & rules framed there under, repair/ replacement cost, daily water quality analysis, chemical cost, grease, m-oil, annual painting of structures, water quality recording ,training of departmental employees etc shall be included in the contract on SITC/Turnkey Basic. The defective parts shall have to be replaced by the agency / manufacturer during the contract period. The turnkey job shall include all kinds of consumables and spares required for smooth operation for a period of 05 years and have to be supplied and installed by the contractor from time to time and as and when required. The firm has to attend the site immediately as and when the quality of water is found to be below acceptable norms. |
503 | Construction of CGI Color Coat Sheeted angle iron shed 8m x 4m x 4m and cement concrete base for IRP as per load bearing capacity. The CGI shed with all sides closed and as per layout of the plant and site requirement and shall be complete with suitable doors, windows, roofing, complete in all respects Earth excavation work of Foundation Size = 8.3mX4.3mX0.3m |
504 | Providing and laying of dry stone soling hand packed in trenches. 1 foot (0.3m) |
505 | P/L of (1:1.5:3) mix cement concrete including loading and unloading.External Block 8.3mX0.456mX0.61mX 2No+ 3.4mX0.45mX0.61mX2 No |
506 | Providing and laying of soling stone including manual compaction7.39mX3.39mX0.456m |
507 | P/L of (1:2:4) mix cement concrete including loading and unloading. Size=7.39mX3.39mX0.15m |
508 | P/L of (1:1.5:3) mix cement concrete including loading and unloading. External Block Size=8.3mX4.3mX0.1m |
509 | Centering and shuttering including strutting , propping etc. and removal of form work for: Foundation, footings, bases for columns Size= 2X{8.3+4.3}X0.61= 15.37 & 2{7.39+3.39}X0.61=13.15 |
510 | P/L of 12 mm thick plaster in 1:4mix Size= 8.3X4.3=35.69 2x8.3x.61+2x4.3x.61=15.4 |
511 | Construction of Ramp of following specifications:- Earth excavation work of Foundation Size = 1.83mX1.83mX0.3m |
512 | Providing and laying of dry stone soling hand packed in trenches. 1 foot (0.3m) Size=1.83mX1.83mX0.3m |
513 | P/L of (1:2:4) mix cement concrete including loading and unloading. Size=1.83mX1.83mX0.61mX0.5 |
514 | Centering and shuttering including strutting , propping etc. and removal of form work for: Foundation, footings, bases for columns Size= {2X1.83+2X1.83}X0.61 |
515 | P/L of 12 mm thick plaster in 1:4mix Size= 1.83X1.83+0.61X1.83 |
516 | Fabrication of CGI shed by way of providing structural steel in built up sections, trusses and frame work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete welded. Angle Iron Structure of 8m x 4mx4m size Shed. |
517 | Providing and fitting of anti bird iron net with square mesh around CGI shed to top 0.60m height for avoiding birds to enter inside shed. |
518 | Providing and fitting of semi transparent white Fiberglass corrugated roofing sheets(FRP) 2.0mm thick on sides of shed.As Per JKSOR Code No: -12.22.1 |
519 | Providing corogated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8mm dia. with bituman and GI limpet washers filled with white lead including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete ( upto any pitch in horizontal / vertical or curved surface) excluding the cost of purlins, rafters, and trusses and including cutting to size and shape wherever required 0.80mm thick with zinc coating not less than 275grm/sqm. |
520 | Providing ridges or hips of width 60cm overall with plain GS sheets fixed vwith polymer coated J or L hooks bolts and nuts 8mm dia GI limpet and bituman wasger complete 0.63 mm thick with zin coating not less than 275grm/ sqm |
521 | Providing and fitting of 2m wide, 3.4m in height MS Rolling Shutter having the horizontal slates hinged together and is raised to open and lowered to close it. |
522 | Providing and fitting of, DN 80 mm PN 1.6/16Ductile Iron double flanged, non-rising spindle soft seated glandless gate/ sluice valves as per IS14846 for regulating the water supply outside the pumping units . The body and bonnent of the valve shall be of ductileiron, wedge with fully vulcanized EPDM rubber(Approved for drinking water) and NBR seal. The Gate/Sluice valve shall be compatible for buried applications and shall be safe to install in both horizontal and vertical positions It shall have electrostatic epoxy coating(approved for drinking water) both inside and outside of the valve. The valve shall be supplied along with hand wheel. Cost on account of Nuts, bolts, gaskets, etc required for the job is included in the scope of work. The job includes providing and fitting of 02 nos. M.S flanges perfectly adaptable to the inbuilt flanges of the valve which shall be fitted with rising main of the pumping unit at appropriate spots as per site requirement. The job includes the cost on account of P/F of nuts, bolts and gasket required for the job. |
523 | Providing and fitting ofDN 80 mm PN 1.6/16Ductile Iron double flanged, Slanted seat swing check valve( NRV) as per IS 5312. The body shall be of ductile cast iron with fully encapsulated vulcanized EPDM rubber(Approved for drinking water). The valve shall be compatible for buried applications and shall be safe to install in both horizontal and vertical positions. It shall have electrostatic epoxy coating (approved for drinking water) both inside and outside of the valve. Cost on account of Nuts, bolts, gaskets, etc required for the job is included in the scope of work. The job includes providing and fitting of 02 nos. M.S flanges perfectly adaptable to the inbuilt flanges of the valve which shall be fitted with Rising main of the pumping unit at appropriate spots as per site requirement. The job includes the cost on account of P/F of nuts, bolts and gasket required for the job. |
524 | Providing, fitting, testing and commissioning of 50 voltage stabilizeras per specifications below: Type of voltage controller: Manually operated copper wound, 3-phase, AC power supply multi step. Type of Regulator: Double plate type with electrolytic copper contacts. Input voltage : 150-400 volts.(3 phase) Output voltage : 400 ±10% volts. Frequency : 50±3 C/S. Windings : Electrolytic grade copper of adequate section, vacuum impregnated andOven-dried. Insulation : Fiber glass insulations to tested parameters. Cooling: Naturally, Oil cooled Temp. Rise (Max) : 30°C above ambient Mounting : On Uni-directional wheels. Correction rate : 30 volts per step Wave form distortion: virtually nil Duty cycle : 100% continuous. Enclosure : MS sheet enclosure in pressed CGR Sheet powder coated with radiators. Core laminates: High grade, low eddy loss, grain oriented silicon steel laminations. Load: Three phase induction motor load. Load Amperes (continuous) Overload in 24-hours operation: 10% above continuous Ampere rating. The voltage stabilizer shall have T-oil level indicator gauge preferably glass type tube or otherwise visible to naked eye. The top of the container to have a display panel for housing 02 numbers Digital voltmeters (0-500V) along with 4-way selector switch and set of neon indicators for incoming and outgoing phases (06 No’s). Insulating media (T. Oil) of 11 KVA grade to be provided and filled upto top level, with dielectric strength of 5 KV at 4m air gap. The T-Oil of specific grade should be provided in separate barrels and filled at site upto top level. The voltage Stabilizer shall be accepted with manufacturers dully stamped test certificate and shall have name plate with specifications. |
525 | Providing and Fitting of 3.5-Core, XLPE, 1.1KV LTgrade 50 square mm Armoured Aluminium Cable of various sizes conforming to IS: 7098 part 1st as service line from the HT transformer to control panel including necessary thimbling, crimping, taping etc. |
526 | Providing and fitting of 3-Core flat 16 square mm submersible copper cable conforming to IS: 694 (Part 1st) – 1964 & IS: 694 (Part 2nd) - 1964 for Submersible Pumping Unit and other electrical Equipments . The cable connections terminal shall be fitted with copper thimbles of required size. : |
527 | Providing and fitting of 25 mm square single core copper cable for intwrconnecting various electrical gadets as per IS 694: 2010 along with necessary thimbling etc |
528 | Supply, installation of 6 kg Co2 type fire extinguisher manufactured as per IS:15683 OF 2006 with IS mark and comply with DGMS(Approval) . The co2 extinguisher should be suitable for class B & C fire and also for fire involving electrical equipments. the cylinder used for fire extinguisher shall be approved by protroleum andexplosive safety organization(PESO) as per gas cylinder rules 2004 and as per IS: 7285 of 2004. The body should be made of seamless steel (manganese) confirming to IS:7285 with IS mark and should be provided with squeeze grip nozzle and should be filled with co2 confirming to IS : 15222 of 2002 with certificate.The extinguisher shall be provided with manufactures test certificate and hydraulic test certificate by BIS from PESO. |
529 | Illumination of Premises: Providing and erection of 9 Mtr long Hot Dip Galvanized octagonal pole (single Section) with bottom 150mm, top 75mm wide, thickness 3mm with 70 Microns Zinc coating having inside arrangement for providing of power connection along with following items. 1) 3 Way Terminal Connector 20 Amp. 2) 3 No MCB 8 Amp. The job includes fabrication, providing and fitting of three arm GI structure at the top having 120° angle between arms and each arm having 15° inclination with respect to horizontal plane. Each arm should be of 2’ length and size and shape appropriate as per requirement of the luminary. The job also includes providing and fitting of required length of flexible multi strand 2 mm copper wire from each terminal connector to each holding arm. The pole is mounted on 1:2:4 Cement concreting of size not less than 2’x2’x6” ( cost of concreting not included in the job) using 04 No anchor bolts of required size not less than 7” in length. The complete job includes earthing in GI Electrode as per relevant IS Code |
530 | Providing, installation, testing and commissioning of area lighting 120 Watt LED (Street Light Type) on top of octagonal pole vide item No.36 Having following specs: Input: 90-240 V 50 Hz Power Factor: >0.9 Colour Temperature: 4K - 6.5K Beam Angle: 120° - 170° Lumens: >12000 Operating Temperature: -20°C to 60°C The LED is pressure die cast aluminum housing with power coated finish and having Ingress Protection up to IP-68. The LED is properly fitted on the arm of the pole and connected to the copper wire as provided inthe high mast pole |
531 | Providing Laying and connection of 2Cx10 mm² XLPE Aluminum Armored Cable from the connector of high mast pole to the stabilizer. The job includes underground laying or overhanging and thimbling as per requirement and directions of the site in-charge. |
532 | Providing and installation of Junction Box with DP 32 A MCB to serve as Main switch for LED Lighting. The job includes making of electric connection to the circuit. |
533 | Providing, Installation and testing of 2KVA fully automatic voltage stabilizer with input voltage 70-240 V and output 220 V. The stabilizer shall be installed and connected to the electric circuit as per location provided by site incharge. |
534 | Supply, installation, Testing & commissioning of 1000VA Full Sine wave power inverter (Make: Reputed) including Providing / Installation of 12V, 180AH Tubular inverter Battery with trolley and cover. (Make: Reputed) with 2-core 6mm2 Cu wiring as per site requirement along with other accessories like SS-Combine (02 No’s), 3-pin plugs etc of reputed make for proper fitment and installation of the item. |
535 | Miscellaneous Items |
536 | Providing, laying & fixing with adhesive/bonding material of insulation rubber mats on the floor of the pump house, covering area around electro-mechanical machinery for safeguarding the life & limb of the workmen due to possible leakage of current & short circuit. The floor surface shall be made good & shall be free from dust, grease, foreign material & moisture free. The mats shall be as per IS 15652:2006 & shall have the following specifications: - Composition: Rubber (synthetic mats for electrical purpose) Thickness: - 2.5mm Size: - 1M wide. Make: - Reputed The rubber mats shall be accepted with manufacturers test certificate |
537 | TOOL KIT For Maintenance: - The Tool Kit for maintenance shall comprise of the following and all the items as mentioned below shall be of Reputed make: SPECIFICATIONS AS PER TECHNICAL ANNEXURE OF SBD |
538 | Fabricationof6’ x 6’ angle iron bed by way of providingand fitting of Structural steel in built up sections , trusses and framed work, including cutting , hoisting , fixing in position and applying a priming coat of approved steel primer all complete welded |
539 | Providing and fitting of 19 mm thick multilayered ply sheet of size 6 x 3 feet , 2 nos including cutting , fixingall complete including painting of the play sheet by one coat of primer and two coats of enamel paint |
540 | a) Providing of good quality bedding for night stay/Shift consisting of: - i) Mattress with warm cover size 6"x3" (6Kg)- 02 No’s ii) Quilt with warm cover size 5"x8" (6Kg)- 02 No’s iii) Pillows with covers - 02 No’s iv) Single bed warm blankets with one sided Fur- 02 No’s The filling material for mattress, quilt and pillow shall be of good quality cotton b) The job also includes providing of pressure cooker 5ltr 02 No’s, Steel patila( utensil) 5ltrs 02 No’s, cooking heater 01 No., room heater 01 No., steel buckets 10 litre capacity 01 No., Plastic bucket 10 litre capacity with Mug 02 No’s each, steel glasses 06 No’s, steel Plates with large spoons and bowls 03 No’s each, Cup and Saucer set (01 No. Set) and, 5kg Gas cylinder with burner/ stove. All the utensils shall be of Prestige, Pigeon, Wonder chef, United, Futura make. The job also includes providing of thermo-cool 15’x12’ along with excel matting of 15’x12’ size. The job also includes providing of unbreakable Plastic Chair table set consisting of chairs 04 No’s, extra heavy Table 01 No. of Samruddhi/ Neel kamal/Supreme /Anmol Make. The job also includes providing of good quality safety Door locks (03 No’s) of Godrej, Link locks, Thapar make. |
541 | Providing of solar/ electrical lantern chargeable on both solar & electrical 220v supply. |
542 | Providing of bamboo ladders 18 feet long along with 15 feet long Link rods and HT Glove pair (01 No each) |
543 | Providing of 1 KW heat convector for operators for winter season. |
544 | Providing and fitting of 01 No. LED (scroll type) sign board fabricated out of stainless steel and metal showing the names of water supply scheme and the Department. Size:6’×1’6” |
545 | Providing and fitting of 01 No. angle iron/sheet metal board duly painted showing various specifications of the mechanical and electrical equipments installed at site. Size: 4’×6’ out MS ANGLE OF 40X 40X 5of 36 rft and MS sheet of 1 mmthicktotal weight of50.16 kgs |
546 | Electric Substation Works |
547 | Supply, installation, commissioning and Creation of pole mounted , outdoor type 63 KVA Electric Sub Station as per the technical specifications given here under - Specifications conforming to IS : 1180 (Part 1) 2014 with latest amendments . Type: HT/LT Transformer Type of cooling:ONAN. Operating conditions: Input=11000 volts Output =433 volts AC supply in 3- phase. Terminals: Input=3 No. HT bush rods with insulators, washer, nuts etc. Output=4 No. LT bush rods switch insulators, washers, nuts etc. Core: The core shall be of high permeability to reduce core losses and the strips shall be of suitable size and gauge. Transformer Coils: Suitable number of HT and LT coils in each leg of the core. The transformer coils shall be fabricated out of superior quality aluminum wire/strips, properly wound. The HT transformer is completely filled with suitable grade transformer oil up to required level. The job includes carriage,and all leads and lifts involved. The HT transformer shall be of reputed make from an ISO certified company as per relevant standards and a test certificate shall be provided before installation. The transformer shall also be provided with breather fill with silica jel crystals , conservator with oil level indicator , explosion vet and adequate radiator fins/ Tubes. The impedance of transformer shall be as per IS:1180 (Part 1) 2014 with latest amendments. NOTE: The scope of the work shall include obtaining of necessary inspection/clearance certificate from the concerned department for all the required equipment. The testing and commissioning shall be completed only after obtaining above certificate. |
548 | Providing and fittingG.I Channel /Angle/ Flat of sizes including clamps |
549 | Supply, Installation, Testing and commissioning of Polymeric Gang operated Air break switch, outdoor type, triple pole, suitable for vertical installation, single break provided with locking arrangement at both ON and OFF position consisting ofHT post double insulator, copper or copper alloy high pressure heavy contact assembly, rod with bearings , operating handle and 2 length of 32mm dia. GI pipe conforming to IS 1818 1961, 06 No. of insulators, rated voltage 11KV 200A complete as per IS specs. |
550 | Supply, Installation, Testing and commissioning of 11KVpolymer fuses SetHorn Gap3-phase 200 Asuitable for vertical installation . |
551 | Supply, Installation, Testing and commissioning ofGapless Surgearrestor station class, 10KA, 9KV, LA With polymer housing , Station Type . |
552 | Supply and fitting of 11 KV polymeric composite pin insulator 12 KV, 5KN, Lighting impulse 75KV Positive, and 80 KV Negative , creepagedistance 320 mm |
553 | Supply, installation, errection of9 mtrslongH.T pope of specificationsST- 410 (sp-33) . the job further includes drilling of holes for installation of various accessories .wherever requiredthe job further includes G.I wire earthing of pole as per REC standard. |
554 | P/F of Galvanized nuts, bolts of various sizes as per site requirement. |
555 | P/F Danger Plate with clamps |
556 | Providing and fixing G.I Barbed wire for anti climbing/ anti-climbing devices |
557 | Providing and fitting of Galvanized stay set with 50 X 8 mm Stay Clamp , Guy insulator (2no.), Anchor plate (200X200X6mm) , nuts and bolts , 2 N0- turn buckle , 1.8 m long , 16 mm diameter solid G.I stay rod & 7/3.15 mm dia. G.I stranded wire complete. |
558 | Painting of poles Red oxide |
559 | Painting of poles Aluminum paint |
560 | Providing and fitting of ACSR as per IS 398 (part-2) 1996 for 50 sq.mmACSR (Galvanised steel reinforced) for fitment of various accessories |
561 | Supply, Installation and Testing of 35 Sq mm XLPE Aluminum H.Tcable (ABC type) of 11 KV grade with following specs. Size (cross sectional area in sq mm) = 3×35 Phases:Red, Yellow, Blue |
562 | Providing and fitting of suspension/ tension clamp with Eye Hooks required for holding of 3 – Core, 35 Sq. mm H.T AB Cable. |
563 | P/F of 11 KV cable termination kit for connecting 35 Sq mm XLPE cable (ABC type) with the existing HT line near tapping point and HT transformer. |
564 | P/I/T/C of LT 3 phase, 4 wire, Prodigy meter of capacity 40-200 Amp, 415 V, 50 Hz preferably of Secure make with all accessories & fittings, cabling required as pe site requirement.NOTE:- The job includes complete charging of subsation which includes getting clearnace from PDD and sealing of meter etc. |
565 | P/I of earthing station for 63 KVA electric substation, LT panel and stabilizer comprising of company fabricated earthing electrode as per IS: 3043. The job includes Auguring of bore of required dia/depth for installation of electrode along with backfill compound mixed with soil and all other items required thereof for achieving the best result. The job includes connecting of electric gadgets through GI strip as per relevant standards. Safe earthing electrode size:80 mm dia , Length :2000 mm Back fill compound :30 kg |
566 | Earthing complete by GI pipe 40mm or GI rod 3 m long through GI strip 25x3mm |
567 | Providing and fitting of LT Distribution box for H.T transformer with MCCB For incomer and SFU for outgoing circuits, the capacity of H.T Transformeris 63 KVA |
568 | Earth work in excavation by manual means in trenches for foundation, drains, pipes, cables (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and reaming of bottom lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed. all kinds of soil. |
569 | Providing and laying of soling stone including manual compaction |
570 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering . all work upto plinth level with 1: 2 :4 mix (1 cement, 2 coarse sand, 4 graded stone aggregate 20mm nominal size) |
571 | 19.WSS Nowhar Malapora (Adv. Cost: Rs. 5,12,577/-) |
572 | De-silting/cleaning of 5000 GPH Tube Settler filtration plant by way of Pre Settling tank Disassembling of the light weight FRP strips/pieces fitted in tongue and groove arrangement from slots of Pre -settling tank by using skilled labour, tools and tackles with utmost care and precautions to avoid damage to. - The dismantled FRP strips have to be shifted to a safer place for its stacking and stacking properly to avoid any fracture or damage of the FRP Strips/pieces and include all head load involved in carrying the job at site. - The FRP strips so dismantled are to be taken one after another and cleaned from both sides using brushes, soap scrubbers and other cleansing agents for removing the crust layer of silt/mud and other foreign bodies accumulated on it to achieve a clean and smooth surface. - The area of the Pre Settling Tankbelow the slots for fitment of FRP Plates /strips need to be cleared off from the accumulated silt on walls including bottom portionof MS tank. The job is to be carried out by skilled Labour, tools and tackles as required for carrying out the job at site. - After Cleaning of PVC strips, MS PRE Settling Tank shall have be cleaned inside and outside by way of using brushes, soap scrubbers and other cleansing agents for removing the crust layer of silt/mud and other foreign bodies accumulated on it to achieve a clean and smooth surface. - The FRP strips after cleaning are again to be installed in the slots of thePre settling tank at its proper place and position of fitment with utmost care and precautions to be taken to avoid any damage to the FRP Strips to achieve the required surface area as designed for the flocculator of the presetting tank. Flocculater Tank , Alum Mixing Chamber & Agitator chamber - Flocculator Chamber and Alum Mixing Chamber shall have to be cleaned inside thoroughly by way of using brushes, soap scrubbers and other cleansing agents for removing the crust layer of silt/mud and other foreign bodies accumulated on it to achieve a clean and smooth surface. The includes dismantling ofprime movers and blades / churner so that proper cleaning is achieved. [16 Labours @503/Labour] |
573 | P/F of UV insulated 2 mm thick corrugated FRP sheets . |
574 | Removal of choked filter media from pressure filter vessel .The job includes all loads and lifts, disposal of choked media to dumping site outside the premises of the plant. De-silting of pressure vessel Chamber shall have to be cleaned inside thoroughly by way of using brushes, soap scrubbers and other cleansing agents for removing the crust layer of silt/mud and other foreign bodies accumulated on it to achieve a clean and smooth surface following the removal of chocked filter mediafrom the vessel manually . The vessel needs to be cleaned properly and dried before laying of fresh media [10 Labours @733/Labour] |
575 | Providing and laying of filter media of specific size and grade to be laid in 5000/6000 GPH Pressure vessel duly washed, free from dust, dirt, loom and any other inorganic material or suspension .the job includes carriage of filter media from Ganderbal to site including all loads and lifts required on the site condition. The media is to be lad in different layers of specific size and grade from bottom to top over the filter bed plate. The bottom layer is to be laid without tilling/damaging the pressure nozzles. |
576 | Providing and fitting of 12 mm dia. Fine threaded PVC nozzles auxiliary type to be fitted on filter bed plate of pressure vessel. |
577 | Providing and fitting of 29 inch. Dia. rubber washers /gaskets for manhole and inspection chamber and opening of pressure filter vessel. |
578 | Replacement of agitator / flash mixer in alum solution holding tank fabricated out of wetted parts in stainless steel, speed 20-30 rpm .intermediate bearing paddle type twin blades free standing type. |
579 | P/I/T/C of air scavenging/blower unit of following parameters Capacity: -145 cubic meter per hour rating 0.4 bar Pressure: -5PS10 Speed: - 1450 RPM Motor As per requirement |
580 | Providing and fitting of pressure gauges with adopters to replace damaged ones these pressure gauges should be in the range of 0-50 kgf/cm/sg and be reputed make. |
581 | P/F of various size Butterfly Valves. The job includes providing and fitting of nuts and bolts and washers with allied mechanical works |
582 | Replacement of 80 mm dia. cast iron diaphragm valves by way of inducing fresh DI Gate/Butter fly valves with pressure rating of PN16. The job includes providing and fitting of nuts and bolts and washers and necessary mechanical works |
583 | Painting with synthetic enamel paint two or more coats of approved brand and bar pressure clarifier pressure filter vessel, fittings and complete piping after cleaning of dirt by kerosene oil and application of steel primer of specific grade. |
584 | P/F of 03 no’s CI 80 mm (Ball Valves-Reputed make) The job includes providing and fitting of nuts and bolts and washers with allied mechanical works with fittings etc. |
585 | P/I/T/C of backwash pumping equipment of following parameters Discharge-16lpsHP-5, Head range6-15mtr |
586 | Providing and fixing ofnuts and bolts of required sizeand thickness |
587 | Providing, fitting, testing and commissioning of 40 kvavoltage stabilizeras per specifications below: Type of voltage controller: Manually operated copper wound, 3-phase, AC power supply multi step. Type of Regulator: Double plate type with electrolytic copper contacts. Input voltage : 175-400 volts.(3 phase) Output voltage : 400 ±10% volts. Frequency : 50±3 C/S. Windings : Electrolytic grade copper of adequate section, vacuum impregnated andOven-dried. Insulation : Fiber glass insulations to tested parameters. Cooling: Naturally, Oil cooled Temp. Rise (Max) : 30°C above ambient Mounting : On Uni-directional wheels. Correction rate : 30 volts per step Wave form distortion: virtually nil Duty cycle : 100% continuous. Enclosure : MS sheet enclosure in pressed CGR Sheet powder coated with radiators. Core laminates: High grade, low eddy loss, grain oriented silicon steel laminations. Load: Three phase induction motor load. Load Amperes (continuous) Overload in 24-hours operation: 10% above continuous Ampere rating. The voltage stabilizer shall have T-oil level indicator gauge preferably glass type tube or otherwise visible to naked eye. The top of the container to have a display panel for housing 02 numbers Digital voltmeters (0-500V) along with 4-way selector switch and set of neon indicators for incoming and outgoing phases (06 No’s). Insulating media (T. Oil) of 11 KVA grade to be provided and filled upto top level, with dielectric strength of 5 KV at 4m air gap. The T-Oil of specific grade should be provided in separate barrels and filled at site upto top level. The voltage Stabilizer shall be accepted with manufacturers dully stamped test certificate and shall have name plate with specifications. |
588 | 20.WSS Reban Khojipora (Adv. Cost: Rs. 5,81,057/-) |
589 | Providing and fitting of 3-Core flat submersible copper cable conforming to IS: 694 (Part 1st) – 1964 & IS: 694 (Part 2nd) - 1964 for Submersible Pumping Unit and other electrical Equipment. The cable connections terminal shall be fitted with copper thimbles of required size. The main specification of the cable is given below: Rest specification as per cluase "47" of SBD. Size: 10 sqmm |
590 | Providing, fitting, testing and commissioning of 30 voltage stabilizeras per specifications below: Type of voltage controller: Manually operated copper wound, 3-phase, AC power supply multi step. Type of Regulator: Double plate type with electrolytic copper contacts. Input voltage : 175 -400 volts.(3 phase) Output voltage : 400 ±10% volts. Frequency : 50±3 C/S. Windings : Electrolytic grade copper of adequate section, vacuum impregnated andOven-dried. Insulation : Fiber glass insulations to tested parameters. Cooling: Naturally, Oil cooled Temp. Rise (Max) : 30°C above ambient Mounting : On Uni-directional wheels. Correction rate : 30 volts per step Wave form distortion: virtually nil Duty cycle : 100% continuous. Enclosure : MS sheet enclosure in pressed CGR Sheet powder coated with radiators. Core laminates: High grade, low eddy loss, grain oriented silicon steel laminations. Load: Three phase induction motor load. Load Amperes (continuous) Overload in 24-hours operation: 10% above continuous Ampere rating. The voltage stabilizer shall have T-oil level indicator gauge preferably glass type tube or otherwise visible to naked eye. The top of the container to have a display panel for housing 02 numbers Digital voltmeters (0-500V) along with 4-way selector switch and set of neon indicators for incoming and outgoing phases (06 No’s). Insulating media (T. Oil) of 11 KVA grade to be provided and filled upto top level, with dielectric strength of 5 KV at 4m air gap. The T-Oil of specific grade should be provided in separate barrels and filled at site upto top level. The voltage Stabilizer shall be accepted with manufacturers dully stamped test certificate and shall have name plate with specifications. |
591 | Providing and fittingG.I Channel /Angle/ Flat of sizes including clamps |
592 | Supply, Installation, Testing and commissioning of Polymeric Gang operated Air break switch, outdoor type, triple pole, suitable for vertical installation, single break provided with locking arrangement at both ON and OFF position consisting ofHT post double insulator, copper or copper alloy high pressure heavy contact assembly, rod with bearings , operating handle and 2 length of 32mm dia. GI pipe conforming to IS 1818 1961, 06 No. of insulators, rated voltage 11KV 200A complete as per IS specs. |
593 | Supply, Installation, Testing and commissioning of 11KVpolymer fuses SetHorn Gap3-phase 200 Asuitable for vertical installation . |
594 | Supply, Installation, Testing and commissioning ofGapless Surgearrestor station class, 10KA, 9KV, LA With polymer housing , Station Type . |
595 | Supply and fitting of 11 KV polymeric composite pin insulator 12 KV, 5KN, Lighting impulse 75KV Positive, and 80 KV Negative , creepagedistance 320 mm |
596 | Supply, installation, errection of9 mtrslong H.T pope of specificationsST- 410 (sp-33) . the job further includes drilling of holes for installation of various accessories .wherever requiredthe job further includes G.I wire earthing of pole as per REC standard. |
597 | P/F of Galvanized nuts, bolts of various sizes as per site requirement. |
598 | P/F Danger Plate with clamps |
599 | Painting of poles Red oxide |
600 | Painting of poles Aluminum paint |
601 | Supply, Installation and Testing of 35 Sq mm XLPE Aluminum H.Tcable (ABC type ) of 11 KV grade with following specs. Size (cross sectional area in sq mm) = 3×35 Phases:Red, Yellow, Blue |
602 | Providing and fitting of Galvanized stay set with 50 X 8 mm Stay Clamp , Guy insulator (2no.), Anchor plate (200X200X6mm) , nuts and bolts , 2 N0- turn buckle , 1.8 m long , 16 mm diameter solid G.I stay rod & 7/3.15 mm dia. G.I stranded wire complete. |
603 | Providing and fitting of suspension/ tension clamp with Eye Hooks required for holding of 3 – Core , 35 Sq. mm H.T AB Cable. |
604 | P/F of 11 KV cable termination kit for connecting 35 Sq mm XLPE cable (ABC type) with the existing HT line near tapping point and HT transformer. |
605 | Earth work in excavation by manual means in trenches for foundation, drains, pipes, cables (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and reaming of bottom lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed. i. All kinds of soil (80 % )01 meter from cutting edge |
606 | ii. Ordinary rock(20%)01 meterfromcutting edge |
607 | Providing and laying of soling stone including manual compaction |
608 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering . all work upto plinth level with 1: 2 : 4 mix (1 cement , 2 coarse sand , 4 graded stone aggregate 20mm nominal size) |
609 | Illumination of Premises: Providing and erection of 9 Mtr long Hot Dip Galvanized octagonal pole (single Section) with bottom 150mm, top 75mm wide, thickness 3mm with 70 Microns Zinc coating having inside arrangement for providing of power connection along with following items. 1) 3 Way Terminal Connector 20 Amp. 2) 3 No MCB 8 Amp. The job includes fabrication, providing and fitting of three arm GI structure at the top having 120° angle between arms and each arm having 15° inclination with respect to horizontal plane. Each arm should be of 2’ length and size and shape appropriate as per requirement of the luminary. The job also includes providing and fitting of required length of flexible multi strand 2 mm copper wire from each terminal connector to each holding arm. The pole is mounted on 1:2:4 Cement concreting of size not less than 2’x2’x6” ( cost of concreting not included in the job) using 04 No anchor bolts of required size not less than 7” in length. The complete job includes earthing in GI Electrode as per relevant IS Code |
610 | Providing, installation, testing and commissioning of area lighting 120 Watt LED (Street Light Type) on top of octagonal pole vide item No.36 Having following specs: Input: 90-240 V 50 Hz Power Factor: >0.9 Colour Temperature: 4K - 6.5K Beam Angle: 120° - 170° Lumens: >12000 Operating Temperature: -20°C to 60°C The LED is pressure die cast aluminum housing with power coated finish and having Ingress Protection up to IP-68. The LED is properly fitted on the arm of the pole and connected to the copper wire as provided inthe high mast pole. |
611 | Providing Laying and connection of 2Cx10 mm² XLPE Aluminum Armored Cable from the connector of high mast pole to the stabilizer. The job includes underground laying or overhangingalong with thimbling as per requirement and directions of the site in-charge. |
612 | Providing and installation of Junction Box with DP 32 A MCB to serve as Main switch for LED Lighting. The job includes making of electric connection to the circuit. |
613 | Providing, Installation and testing of 2KVA fully automatic voltage stabilizer with input voltage 70-240 V and output 220 V. The stabilizer shall be installed and connected to the electric circuit as per location provided by site incharge. |
614 | 21.WSS Safanagri (Adv. Cost: Rs. 16,51,458/-) |
615 | Supply, installation, testing and commissioning of Horizontalpumping unit as per IS 1520 with following specification:- Pump:- 1.Type :-Horizontal split casing/MultistageDischarge 8000GPH , 70 Mtr Head Material of construction 1.Impeller:- S.steel 2.Shaft:-SS410 3.Pump casing:- Cast Iron 4. RPM 1440 The pump shall confirm to IS-1520 code MOTOR :- A)Type :- Horizontal squirrel cage Induction Type B) Rating:- Suitable for above parameters but not less than 25 HP. C)No of phases: 3 phase415 V+10%,50 Hz, AC supply D)Winding:-Copper wound squirrel cage E) Type of enclosure:-SPDP/TEFC F) Method of cooling:- Air cooled with fan mounted G)Method of Starting: star delta H) RPM 1440 The pump-motor should be mounted on a common base frame fabricated out of M.S channel of suitable size and duly fitted with T- type foundation bolts /nuts and washers to make the pumping unit vibration free. The pump and motor should be coupled through suitable coupling. The coupling faces checked for both angular and axial alignment with the help of tapered gauges/feeler gauges or dial indicator.Job includes Testing and Commissioning of pumping unit on full load at site. Manufacturers Test Cerrtificateto be appended. |
616 | Supply, Installation, Testing & Commissioning of Open Well Pumping Units as per IS 14220 at Filter Water Stage. PUMP: - Discharge 8000 GPH 70 Mhead • Type of pump:Open wellSubmersible Pump (vertical ) • Quality of Water to be handled :Filter water METERIAL OF CONSTRUCTION: • Pump Casing:Cast Iron • Impeller :SS • Pump Shaft:Stainless Steel • Motor Body: Cast Iron • Sealing :Dual mech. seal ? The bowl plate shall be provided with name plate giving complete specifications MOTOR: - • Rating : Suitable for above parameterNot less than 15hp • Method of starting:Star – Delta. • Frequency: 50Hz + 3% • Voltage : 415 + 6 %, -15% • Class of insulation:Suitable for above rating. • Sealing:Dual mech. seal. Provided with thermal and overload protection The motor shall be made of corrosion resisting materials to resist corrosion under normal conditions and the motor shall have a name plate givingcomplete specifications Dual Mechanical Seals (01 No) and Bearings (02 No) for each pumping unit must be provided as spare parts for preventive maintenance by the firm. Note: Test certificate having the Serial No. of the Pumping Unit along with the performance curve in duplicate from the Manufacturer must be produced on delivery of the item. |
617 | Providing, fitting, testing and commissioning of 50 kvavoltage stabilizeras per specifications below: Type of voltage controller: Manually operated copper wound, 3-phase, AC power supply multi step. Type of Regulator: Double plate type with electrolytic copper contacts. Input voltage : 175-400 volts.(3 phase) Output voltage : 400 ±10% volts. Windings : Electrolytic grade copper of adequate section, vacuum impregnated andOven-dried. Insulation : Fiber glass insulations to tested parameters. Cooling: Naturally, Oil cooled Temp. Rise (Max) : 30°C above ambient Correction rate : 30 volts per step Enclosure : MS sheet enclosure in pressed CGR Sheet powder coated with radiators. Core laminates: High grade, low eddy loss, grain oriented silicon steel laminations. Load: Three phase induction motor load. Load Amperes (continuous) Overload in 24-hours operation: 10% above continuous Ampere rating. The voltage stabilizer shall have T-oil level indicator gauge preferably glass type tube or otherwise visible to naked eye. The top of the container to have a display panel for housing 02 numbers Digital voltmeters (0-500V) along with 4-way selector switch and set of neon indicators for incoming and outgoing phases (06 No’s). Insulating media (T. Oil) of 11 KVA grade to be provided and filled upto top level, with dielectric strength of 5 KV at 4m air gap. The T-Oil of specific grade should be provided in separate barrels and filled at site upto top level. The voltage Stabilizer shall be accepted with manufacturers dully stamped test certificate with rest of specifications as per SBD |
618 | Providing and fitting of 3-Core flat 16 square mm submersible copper cable conforming to IS: 694 (Part 1st) – 1964 & IS: 694 (Part 2nd) - 1964 for Submersible Pumping Unit and other electrical Equipments . The cable connections terminal shall be fitted with copper thimbles of required size. : |
619 | Providing and Fitting of 3.5-Core, XLPE, 1.1KV LT grade 50 square mm Armoured Aluminium Cable of various sizes conforming to IS: 7098 part 1st as service line from the HT transformer to control panel including necessary thimbling, crimping, taping etc. |
620 | Supply, installation, commissioning and Creation of pole mounted, outdoor type 63 KVA Electric Sub Station as per the technical specifications given here under - Specifications conforming to IS : 1180 (Part 1) 2014 with latest amendments . Type: HT/LT Transformer Type of cooling:ONAN. Operating conditions: Input=11000 volts Output =433 volts AC supply in 3- phase. Terminals: Input=3 No. HT bush rods with insulators, washer, nuts etc. Output=4 No. LT bush rods switch insulators, washers, nuts etc. Core: The core shall be of high permeability to reduce core losses and the strips shall be of suitable size and gauge. Transformer Coils: Suitable number of HT and LT coils in each leg of the core. The transformer coils shall be fabricated out of superior quality aluminum wire/strips, properly wound. The HT transformer is completely filled with suitable grade transformer oil up to required level. The job includes carriage,and all leads and lifts involved. The HT transformer shall be of reputed make from an ISO certified company as per relevant standards and a test certificate shall be provided before installation. The transformer shall also be provided with breather fill with silica jel crystals , conservator with oil level indicator , explosion vet and adequate radiator fins/ Tubes. The impedance of transformer shall be as per IS:1180 (Part 1) 2014 with latest amendments. NOTE: The scope of the work shall include obtaining of necessary inspection/clearance certificate from the concerned department for all the required equipment. The testing and commissioning shall be completed only after obtaining above certificate. |
621 | Providing and fittingG.I Channel /Angle/ Flat of sizes including clamps |
622 | Supply, Installation, Testing and commissioning of Polymeric Gang operated Air break switch, outdoor type, triple pole, suitable for vertical installation, single break provided with locking arrangement at both ON and OFF position consisting ofHT post double insulator, copper or copper alloy high pressure heavy contact assembly, rod with bearings , operating handle and 2 length of 32mm dia. GI pipe conforming to IS 1818 1961, 06 No. of insulators, rated voltage 11KV 200A complete as per IS specs. |
623 | Supply, Installation, Testing and commissioning of 11KVpolymer fuses SetHorn Gap3-phase 200 Asuitable for vertical installation . |
624 | Supply, Installation, Testing and commissioning ofGapless Surgearrestor station class, 10KA, 9KV, LA With polymer housing , Station Type . |
625 | Supply and fitting of 11 KV polymeric composite pin insulator 12 KV, 5KN, Lighting impulse 75KV Positive, and 80 KV Negative, creepagedistance 320 mm |
626 | Supply, installation, errection of9 mtrslongH.T pope of specificationsST- 410 (sp-33) . the job further includes drilling of holes for installation of various accessories, wherever requiredthe job further includes G.I wire earthing of pole as per REC standard. |
627 | P/F of Galvanized nuts, bolts of various sizes as per site requirement. |
628 | P/F Danger Plate with clamps |
629 | Providing and fixing G.I Barbed wire for anti climbing/ anti-climbing devices |
630 | Providing and fitting of Galvanized stay set with 50 X 8 mm Stay Clamp , Guy insulator (2no.), Anchor plate (200X200X6mm), nuts and bolts, 2 N0- turn buckle, 1.8 m long, 16 mm diameter solid G.I stay rod & 7/3.15 mm dia. G.I stranded wire complete. |
631 | Painting of poles Red oxide |
632 | Painting of poles Aluminum paint |
633 | Providing and fitting of ACSR as per IS 398 (part-2) 1996 for 50 sq.mmACSR (Galvanised steel reinforced) for fitment of various accessories |
634 | Supply, Installation and Testing of 35 Sq mm XLPE Aluminum H.Tcable (ABC type) of 11 KV grade with following specs. Size (cross sectional area in sq mm) = 3×35 Phases:Red, Yellow, Blue |
635 | providing and fitting of suspension/ tension clamp with Eye Hooks required for holding of 3 – Core , 35 Sq. mm H.T AB Cable. |
636 | P/I/T/C of LT 3 phase, 4 wire, Prodigy meter of capacity 40-200 Amp, 415 V, 50 Hz preferably of Secure make with all accessories & fittings, cabling required as pe site requirement.NOTE:- The job includes complete charging of subsation which includes getting clearnace from PDD and sealing of meter etc. |
637 | P/I of earthing station for 63 KVA electric substation, LT panel and stabilizer comprising of company fabricated earthing electrode as per IS: 3043. The job includes Auguring of bore of required dia/depth for installation of electrode along with backfill compound mixed with soil and all other items required thereof for achieving the best result. The job includes connecting of electric gadgets through GI strip as per relevant standards. Safe earthing electrode size:80 mm dia , Length :2000 mm Back fill compound :30 kg |
638 | Earthing complete by GI pipe 40mm or GI rod 3 m long through GI strip 25x3mm |
639 | P/F of 11 KV cable termination kit for connecting 35 Sq mm XLPE cable (ABC type) with the existing HT line near tapping point and HT transformer. |
640 | Earth work in excavation by manual means in trenches for foundation, drains, pipes, cables (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and reaming of bottom lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed. i. All kinds of soil (80 % )01 meter from cutting edge |
641 | ii. Ordinary rock(20%)01 meterfromcutting edge |
642 | Providing and laying of soling stone including manual compaction |
643 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering . all work upto plinth level with 1: 2: 4mix ( 1 cement , 2 coarse sand , 4 graded stone aggregate 20mm nominal size) |
644 | 22.WSS Tahab (Adv. Cost: Rs. 4,45,776/-) |
645 | Supply, installation, commissioning and Creation of pole mounted, outdoor type 63 KVA Electric Sub Station as per the technical specifications given here under - Specifications conforming to IS : 1180 (Part 1) 2014 with latest amendments . Type: HT/LT Transformer Type of cooling:ONAN. Operating conditions: Input=11000 volts Output =433 volts AC supply in 3- phase. Terminals: Input=3 No. HT bush rods with insulators, washer, nuts etc. Output=4 No. LT bush rods switch insulators, washers, nuts etc. Core: The core shall be of high permeability to reduce core losses and the strips shall be of suitable size and gauge. Transformer Coils: Suitable number of HT and LT coils in each leg of the core. The transformer coils shall be fabricated out of superior quality aluminum wire/strips, properly wound. The HT transformer is completely filled with suitable grade transformer oil up to required level. The job includes carriage,and all leads and lifts involved. The HT transformer shall be of reputed make from an ISO certified company as per relevant standards and a test certificate shall be provided before installation. The transformer shall also be provided with breather fill with silica jel crystals , conservator with oil level indicator , explosion vet and adequate radiator fins/ Tubes. The impedance of transformer shall be as per IS:1180 (Part 1) 2014 with latest amendments. NOTE: The scope of the work shall include obtaining of necessary inspection/clearance certificate from the concerned department for all the required equipment. The testing and commissioning shall be completed only after obtaining above certificate. |
646 | Fabrication, Providing and fitting ofModularmotor control panel of appropriate size fabricated out of 14 SWG sheet having required openings/vents and protection Class : IP-55 & fitted with accessories as under: a) Busbar Chamber: 100 Ampres Copper b) Main Circuit Breaker (Incomer MCCB): 4 POLE Qty:- = 02 No Current Rating = 200 Amp. 50 KA c) Change over Switch: Qty. = 01 No. Rating =100 Ampere d) Motor Back-up Protection MCCB: 3 POLE Qnty = 2 No’s Current Rating= 125 A, 36 KA e) Submersible Motor starter: Fully automatic submersible motor starters. Rating =30HP Power Specs =3 ?, 415 + 15% V, 50 + 3 % Hz. Relay range= 30-50 A. Protection = Under voltage/ over Voltage Qty = 02 No’s f) Auxiliary MCCB for Heating/Lighting: Circuit Breaker = MCCB (Outgoing) Qty.= 1 No. Current Rating= 63 Amp. Rest of the specicifications are as per clause-43 ofTechnical annexure of SBD |
647 | Providing and fitting of 3-Core flat 10 square mm submersible copper cable conforming to IS: 694 (Part 1st) – 1964 & IS: 694 (Part 2nd) - 1964 for Submersible Pumping Unit and other electrical Equipments . The cable connections terminal shall be fitted with copper thimbles of required size. : |
648 | P/I of earthing station for 63 KVA electric substation, LT panel and stabilizer comprising of company fabricated earthing electrode as per IS: 3043. The job includes Auguring of bore of required dia/depth for installation of electrode along with backfill compound mixed with soil and all other items required thereof for achieving the best result. The job includes connecting of electric gadgets through GI strip as per relevant standards. Safe earthing electrode size:80 mm dia , Length :2000 mm Back fill compound :30 kg |
649 | 23.WSS Zainapora (Adv. Cost: Rs. 5,67,377/-) |
650 | Supply, installation, testing and commissioning of Horizontalpumping unit as per IS 1520 with following specification:- Pump:- 1.Type :-Horizontal split casing/MultistageDischarge 8000 GPH, 100 Mtr Head Material of construction 1.Impeller:- S.steel 2.Shaft:-SS410 3.Pump casing:- Cast Iron 4.RPM:1440 The pump shall confirm to IS-1520 code MOTOR :- A)Type :- Horizontal squirrel cage Induction Type B) Rating:- Suitable for above parameters. but not less than 30 HP C)No of phases: 3 phase415 V+10%,50 Hz, AC supply D)Winding:-Copper wound squirrel cage E) Type of enclosure:-SPDP/TEFC F) Method of cooling:- Air cooled with fan mounted G)Method of Starting: star delta H) RPM 1440 The pump-motor should be mounted on a common base frame fabricated out of M.S channel of suitable size and duly fitted with T- type foundation bolts /nuts and washers to make the pumping unit vibration free. The pump and motor should be coupled through suitable coupling. The coupling faces checked for both angular and axial alignment with the help of tapered gauges/feeler gauges or dial indicator.Job includes testing and commissioning of pumping unit on full load at site. Test certificate of the Manufacturerer should be appended . Rest of the specicifications are as per clause-5 ofTechnical annexure of SBD |
651 | Fabrication, Providing and fitting ofModularmotor control panel of appropriate size fabricated out of 14 SWG sheet having required openings/vents and protection Class : IP-55 & fitted with accessories as under: a) Busbar Chamber: 200 Ampres COPPER b) Main Circuit Breaker (Incomer MCCB): Qty:- = 02 No Current Rating = 200 Amp.4 Pole 50 KA c) Change over Switch: Qty. = 01 No. Rating =200 Ampere d) Motor Back-up Protection MCCB: Qnty = 2 No’s Current Rating= 125A 3 Pole 36 KA e) Submersible Motor starter: Fully automatic submersible motor starters. Rating = 50HP Power Specs =3 ?, 415 + 15% V, 50 + 3 % Hz. Relay range= 45-75 A. Protection = Under voltage/ over Voltage Qty = 02 No’s f) Auxiliary MCCB for Heating/Lighting: Circuit Breaker = MCCB (Outgoing) Qty.= 1 No. Current Rating= 63 Amp. Rest of the specicifications are as per clause 43g ofTechnical annexure of SBD |
652 | 24.WSS Bonrukh Zahidbagh (Adv. Cost: Rs. 7,89,483/-) |
653 | De-silting/cleaning of 5000 GPH Tube Settler filtration plant by way of Pre Settling tank Disassembling of the light weight FRP strips/pieces fitted in tongue and groove arrangement from slots of Pre -settling tank by using skilled labour, tools and tackles with utmost care and precautions to avoid damage to. - The dismantled FRP strips have to be shifted to a safer place for its stacking and stacking properly to avoid any fracture or damage of the FRP Strips/pieces and include all head load involved in carrying the job at site. - The FRP strips so dismantled are to be taken one after another and cleaned from both sides using brushes, soap scrubbers and other cleansing agents for removing the crust layer of silt/mud and other foreign bodies accumulated on it to achieve a clean and smooth surface. - The area of the Pre Settling Tankbelow the slots for fitment of FRP Plates/ strips need to be cleared off from the accumulated silt on walls including bottom portionof MS tank. The job is to be carried out by skilled Labour, tools and tackles as required for carrying out the job at site. - After Cleaning of PVC strips, MS PRE Settling Tank shall have be cleaned inside and outside by way of using brushes, soap scrubbers and other cleansing agents for removing the crust layer of silt/mud and other foreign bodies accumulated on it to achieve a clean and smooth surface. - The FRP strips after cleaning are again to be installed in the slots of thePre settling tank at its proper place and position of fitment with utmost care and precautions to be taken to avoid any damage to the FRP Strips to achieve the required surface area as designed for the flocculator of the presetting tank. Flocculater Tank , Alum Mixing Chamber & Agitator chamber - Flocculator Chamber and Alum Mixing Chamber shall have to be cleaned inside thoroughly by way of using brushes, soap scrubbers and other cleansing agents for removing the crust layer of silt/mud and other foreign bodies accumulated on it to achieve a clean and smooth surface. The includes dismantling ofprime movers and blades / churner so that proper cleaning is achieved. [30Labours @503/Labour] |
654 | P/F of UV insulated 2 mm thick corrugated FRP sheets . |
655 | Removal of choked filter media from pressure filter vessel .The job includes all loads and lifts, disposal of choked media to dumping site outside the premises of the plant. De-silting of pressure vessel Chamber shall have to be cleaned inside thoroughly by way of using brushes, soap scrubbers and other cleansing agents for removing the crust layer of silt/mud and other foreign bodies accumulated on it to achieve a clean and smooth surface following the removal of chocked filter mediafrom the vessel manually . The vessel needs to be cleaned properly and dried before laying of fresh media [10 Labours @733/Labour] |
656 | Providing and laying of filter media of specific size and grade to be laid in 5000/6000 GPH Pressure vessel duly washed, free from dust, dirt, loom and any other inorganic material or suspension .the job includes carriage of filter media from Ganderbal to site including all loads and lifts required on the site condition. The media is to be lad in different layers of specific size and grade from bottom to top over the filter bed plate. The bottom layer is to be laid without tilling/damaging the pressure nozzles. |
657 | Providing and fitting of 12 mm dia. Fine threaded PVC nozzles auxiliary type to be fitted on filter bed plate of pressure vessel. |
658 | Providing and fitting of 29 inch. Dia. rubber washers /gaskets for manhole and inspection chamber and opening of pressure filter vessel. |
659 | Replacement of agitator / flash mixer in alum solution holding tank fabricated out of wetted parts in stainless steel. Speed 20-30 rpm .intermediate bearing paddle type twin blades free standing type. |
660 | P/I/T/C of air scavenging/blower unit of following parameters Capacity: -145 cubic meter per hour rating 0.4 bar Pressure: -5PS10 Speed: - 1450 RPM Motor As per requirement |
661 | Providing and fitting of pressure gauges with adopters to replace damaged ones these pressure gauges should be in the range of 0-50 kgf/cm/sg and be reputed make. |
662 | P/F of various size Butterfly Valves. The job includes providing and fitting of nuts and bolts and washers with allied mechanical works |
663 | Replacement of 65/80 mm dia. cast iron diaphragm valves by way of inducing fresh DI Gate/Butter fly valves with pressure rating of PN16. The job includes providing and fitting of nuts and bolts and\ washers and necessary mechanical works |
664 | Painting with synthetic enamel paint two or more coats of approved brand and bar pressure clarifier pressure filter vessel, fittings and complete piping after cleaning of dirt by kerosene oil and application of steel primer of specific grade. |
665 | P/F of 03 no’s CI 80 mm (Ball Valves-Reputed make) The job includes providing and fitting of nuts and bolts and washers with allied mechanical works with fittings etc. |
666 | P/I/T/C of backwash pumping equipment of following parameters Discharge-16lpsHP-5, Head range 6-15mtr |
667 | Providing & Fitting of Dozing pumps to doze required quantity of alum/Chlorine in the system. The capacity of the dozing units shall be 0-12 LPH capacity. Dozing pups shall be provided with all required accessories including 200 ltrs. PVC tanks and cable for connection. Each pump shall be provided with 20 mtrs. Cable as per required specification. |
668 | Providing and fixing ofnuts and bolts of required sizeand thickness |
669 | Supply, Installation, Testing & Commissioning of Non-clog Pumping Unit as per IS 5600 at Raw Water Stage. PUMP: - Type of pump:Non–clogOpen wellSubmersible Vertical Pump • Solid Handling Capacity: 20mm (Minimum)• Quality of water:Raw water of river to be handledQ=5000GPH& H=30 m MATERIAL OF CONSTRUCTION: • Pump Casing: Cast Iron • Impeller : Stainless Steel • Pump Shaft: Stainless Steel • Motor Body: Cast Iron • Sealing :Dual mech. seal ? The bowl plate shall be provided with name plate depicting all specifications MOTOR: - • Type : Squirrel Cage 3-Phase Induction Motor• Rating : Suitable for above parameter • Method of starting: Star – Delta. • Frequency : 50Hz + 3% • Voltage : 415± 6 %, -15%• Class of insulation: Suitable for above rating. • SealingDual mech. seal. Provided with thermal and overload protection The motor shall be made of corrosion resisting materials to resist corrosion under normal conditions and the motor shall have a name plate depicting all specifications Dual Mechanical Seals (01 No) and Bearings (02 No) for the pumping unit must be provided as spare parts for preventive maintenance by the firm. for each pumping unit Note: Test certificate having the Serial No. of the Pumping Unit along with the performance curve in duplicate from the Manufacturer must be produced on delivery of the item. . The job includes providing and fitting of flanged delivery pipe G I 80mm dia B class for connectingas per requirement/site conditionwith steel rope and fastenersetc ( head of pumping unit may change approximately by plus minus five percent) Motor Rating= 10 Hp |
670 | Providing/supplying and fitting of G.I flanged Rising Main at site. The Pipe shall be hot dip Galvanized, class Bconfirming to IS 1239. The job includes providing and fitting of M.S Flanges conforming to BIS 6392/1997 Table 17 (Rating PN16). The flanges shall be double welded both from inside and outside of the pipe using standard electrode of reputed make.Flanges (as per IS 6392/1997 Table:17) Thickness shall conform to IS 6392 Part 1st Table-17. Detailed specification as per cluase "8" of of SBD DN80B(Medium ) pipe |
671 | Providing and fitting of 3-Core flat submersible copper cable conforming to IS: 694 (Part 1st) –1964 & IS: 694 (Part 2nd) - 1964 for Submersible Pumping Unit and other electrical Equipment. The cable connections terminal shall be fitted with copper thimbles of required size. The main specification of the cable is given below: Rest specification as per cluase "47" of SBD. size : 6 sq mm |
672 | Providing and fitting of 3-Core flat submersible copper cable conforming to IS: 694 (Part 1st) –1964 & IS: 694 (Part 2nd) - 1964 for Submersible Pumping Unit and other electrical Equipment. The cable connections terminal shall be fitted with copper thimbles of required size. The main specification of the cable is given below: Rest specification as per cluase "47" of SBD. size : 10 sq mm |
673 | Providing and Fitting of 2 core,XLPE, 1.1KV and 1.1KV grade Armoured Aluminum Cable of various sizes conforming to IS: 7098 part 1st as service line from the HT transformer to control panel including necessary thimbling, crimping, taping etc. Rest specification as per cluase "71" of SBD. Size10mm sq |
674 | Repairs/replacements to themodular panel of pumping equipments by way of replacement of damaged contactors MNX 14 MNX-12, MNX-9 ( 8 No) along with thermal overload relaysMN 2 ( Directly operated ) of followingrelay ranges : Relay Range6-10 ( A )/ 0.9 -1.5 / 3-5/(06 Nos) for all pumping units of filtration plantsand replacement ofcontrol wiring, MCCB’s , phase indication lamps, selctor switchs etc and then testing on load. Specifications of Relayscan be varied and shall have to be fitted as asked by the site incharge /AEE. |
675 | Supply, installation, Testing & commissioning of 1000VA Full Sine wave power inverter (Make: Reputed) including Providing / Installation of 12V, 180AH Tubular inverter Battery with trolley and cover. (Make: Reputed) with 2-core 6mm2 Cu wiring as per site requirement along with other accessories like SS-Combine (02 No’s), 3-pin plugs etc of reputed make for proper fitment and installation of the item. |
676 | 25.WSS Imp. Turku Tachloo (Adv. Cost: Rs. 12,08,871/-) |
677 | Supply, Installation, Testing & Commissioning of Submersible Horizontal monoset Pumping Unit for raw water of river as per IS 8034 with following specification are as under : PUMP : Discharge: 10000 GPH at 19 Mts Head Efficiency= Not less than 50% Speed= 2900 Rpm Type of pump = Mixed flow. Type of fluid to be handled=Clear Water MATERIAL OF CONSTRUCTION: Impeller = Stainless Steel Pump Shaft = Stainless Steel SS 410. Pump Casing = Cast Iron/Stainless steel IMPELLER: Impeller is of the enclosed or semi – enclosed type and properly balanced.Enclosed Impellers equipped with seal rings on their hubs. COUPLING: A suitable coupling arrangement provided with pump set. Non Return Valve:- Non Return Valve of the suitable size provided above the pump discharge case. MOTOR:- Method ofstarting = Star – Delta Speed = 3000 (Sync). Frequency= 50 ± 3 % Hz Working Voltage = 380-415 ± 15% V, 03 phase Efficiency = Not less than 90% Rating= not less than 5 HP Class of insulation =F/Suitable for above parameters Submersible motor should be water filled water lubricated squirrel cage type having capacity for above pumping parameters and working on 3 phase; AC supply ranging from 380 to 415 volts, 50Hz. The motor should be sealed by radial rings to avoid mixing of well water with motor filled water. a) The job includes providing and fitting of interlocking arrangement against any failure of coupling. It must be fabricated out of MS strips of suitable size and length. b) The job includes providing and fitting of appropriate size MS nipple 2 feet long threaded on one end and welded to same size MS flange ofthickness (as per Table-17) at other end for 80 mm diameter column pipe as per site requirement. The threaded portion should be as per size of pumping out let for proper fixing. The job includes providing and fitting of R. I. cloth joints/rubber washers with nuts, bolts and washers for all joints of column pipe. The job also includes lowering of pumping unit in the well then proper testing and commissioning of pumping unit on full load at site. Note: Providing of test certificate & Characteristic Curve of pumping equipment is compulsory and pumping unit is to be approved from the concerned Sub Divisional office before procuring. |
678 | Supply, Installation, Testing & Commissioning of Submersible Horizontal monoset Pumping Unit for PST/Sump to liftwater through pressure filterplant upto OHT as per IS 8034 with following specification are as under : PUMP : Discharge: 10000 GPH at 45 Mts Head Efficiency= Not less than 50% Speed= 2900 Rpm Type of pump = Mixed flow. Type of fluid to be handled=Clear Water MATERIAL OF CONSTRUCTION: Impeller = Stainless Steel Pump Shaft = Stainless Steel SS 410. Pump Casing = Cast Iron/Stainless steel IMPELLER: Impeller is of the enclosed or semi – enclosed type and properly balanced.Enclosed Impellers equipped with seal rings on their hubs. COUPLING: A suitable coupling arrangement provided with pump set. Non Return Valve:- Non Return Valve of the suitable size provided above the pump discharge case. MOTOR:- Method ofstarting = Star – Delta Speed = 3000 (Sync). Frequency= 50 ± 3 % Hz Working Voltage = 380-415 ± 15% V, 03 phase Efficiency = Not less than 90% Rating= not less than 15 HP Class of insulation =F/Suitable for above parameters Submersible motor should be water filled water lubricated squirrel cage type having capacity for above pumping parameters and working on 3 phase; AC supply ranging from 380 to 415 volts, 50Hz. The motor should be sealed by radial rings to avoid mixing of well water with motor filled water. a) The job includes providing and fitting of interlocking arrangement against any failure of coupling. It must be fabricated out of MS strips of suitable size and length. b) The job includes providing and fitting of appropriate size MS nipple 2 feet long threaded on one end and welded to same size MS flange ofthickness (as per Table-17) at other end for 80 mm diameter column pipe as per site requirement. The threaded portion should be as per size of pumping out let for proper fixing. The job includes providing and fitting of R. I. cloth joints/rubber washers with nuts, bolts and washers for all joints of column pipe. The job also includes lowering of pumping unit in the well then proper testing and commissioning of pumping unit on full load at site. Note: Providing of test certificate & Characteristic Curve of pumping equipment is compulsory and pumping unit is to be approved from the concerned Sub Divisional office before procuring. |
679 | Providing and fitting of, Ductile Iron double flanged, non-rising spindle soft seated glandless gate/ sluice valves as per IS14846 for regulating the water supply outside the pumping units. The body and bonnent of the valve shall be of ductile iron, wedge with fully vulcanized EPDM rubber (Approved for drinking water) and NBR seal. The Gate/Sluice valve shall be compatible for buried applications and shall be safe to install in both horizontal and vertical positions Rest specification as per cluase "12" of SBD. |
680 | Providing and fitting of 100 mm dia Ductile Iron double flanged, Slanted seat swing check valve (NRV) as per IS 5312. The body shall be of ductile cast iron with fully encapsulated vulcanized EPDM rubber (Approved for drinking water). Rest specification as per cluase "13" of SBD. |
681 | Fabrication, providing and fitting of 100mm dia washout Tee/Y junctionwith arm length 1.2 feet each. The Tee shall be fabricated out of G.I " C-class "pipe with M.S Flanges conforming to BIS 6392/1997 Table 17 (Rating PN16) fastened with weld joints on three ends. |
682 | Fabrication, Providing and fitting of Modular motor control panel of appropriate size fabricated out of 14 SWG sheet having required openings/vents and protection Class : IP-55 & fitted with accessories MU-G 10 Rest specification as per cluase "43 ____" of SBD. |
683 | Providing, fitting, testing and commissioning of voltage stabilizer as per specifications below: Type of voltage controller: Manually operated copper wound, 3-phase, AC power supply multi step. Type of Regulator : Double plate type with electrolytic copper contacts. Input voltage : 250-400 volts.(3 phase) Output voltage : 400 ±10% volts. Frequency : 50 ±3 C/S. Windings : Electrolytic grade copper of adequate section, vacuum impregnated and Rest specification as per cluase "44" of SBD. Rating: 50 KVA |
684 | Providing and fitting of 3-Core flat submersible copper cable conforming to IS: 694 (Part 1st) – 1964 & IS: 694 (Part 2nd) - 1964 for Submersible Pumping Unit and other electrical Equipment. The cable connections terminal shall be fitted with copper thimbles of required size. The main specification of the cable is given below: Rest specification as per cluase "47" of SBD. Size: 10 sqmm |
685 | P/I of earthing station for electric substation, LT panel and stabilizer comprising of company fabricated earthing electrode as per IS: 3043. The job includes Auguring of bore of required dia/depth for installation of electrode along with backfill compound mixed with soil and all other items required thereof for achieving the best result. The job includes connecting of electric gadgets through GI strip as per relevant standards. Safe earthing electrode size : 80 mm dia , Length : 2000 mm Back fill compound : 30 kg |
686 | Supply, installation, Testing & commissioning of 1000 VA Full Sine wave power inverter (Make: Reputed) including Providing / Installation of 12V, 180AH Tubular inverter Battery with trolley and cover. (Make: Reputed) with 2-core 6mm2 Cu wiring as per site requirement along with other accessories like SS-Combine (02 No’s), 3-pin plugs etc of reputed make for proper fitment and installation of the item. |
687 | TOOL KIT For Maintenance: - The Tool Kit for maintenance shall comprise of the following and all the items as mentioned below shall be of Providing of tool kit consists of following items i. Double ended Spanner (Chrome plated) 02 sets complete ii. Double ended Ring spanners chrome plated 02 sets completeiii. Allen key set black finish 02 sets complete iv. Combination Pliers insulated with thick C.A sleeve; size in mm 165, 210, 255 each – 02 No. v. Long nose plier insulated with thick C.A sleeve; size in mm 165, 205 each – 02 No.vi. Side cutting plier insulated with thick C.A sleeve; size in mm 165, 205 make – 02 No.vii. Insulated screw Drivers Blade length in mm Blade dia. in mm Tip dimensions in mm Quantity 50 3 1.6 x 0.4 02 75 3 1.6 x0.4 02 100 3 3 x 0.4 02125 3.5 3.5 x 0.5 02150 3.5 3.5 x 0.5 02 200 4 4 x 0.6 02 300 5 5 x 0.8 02 viii. Hammer with handle weight – 110 mg, 340 gm , 600 gm –each – 1No. ix. Heavy duty pipe Wrench length in mm - 200, 300, 600 each – 01 No.x. Electric Multimeter=1No xi. Digital multimeter – 1No.xii. Digital Clamp tester capable to measure up to 400A - 1 No. xiii. Hack saw frame with hack saw blade – 01 no.xiv. S-16 MXL, S- 16 H X L Socket Set (19 sockets + 6 Accessories) – 01 No. |
688 | Fabricationof6’ x 6’ angle iron bed by way of providingand fitting of Structural steel in built up sections , trusses and framed work, including cutting , hoisting , fixing in position and applying a priming coat of approved steel primer all complete welded |
689 | Providing and fitting of 19 mm thick multilayered ply sheet of size 6 x 3 feet , 2 nos including cutting, fixingall complete including painting of the play sheet by one coat of primer and two coats of enamel paint |
690 | Providing of good quality bedding for night stay/Shift consisting of: - i) Mattress with warm cover size 6"x3" (6Kg)- 02 No’sii) Quilt with warm cover size 5"x8" (6Kg)- 02 No’siii) Pillows with covers - 02 No’s iv) Single bed warm blankets with one sided Fur- 02 No’s The filling material for mattress, quilt and pillow shall be of good quality cotton b) The job also includes providing of pressure cooker 5ltr 02 No’s, Steel patella(utensil) 5ltrs 02 No’s, cooking heater 01 No., room heater 01 No., steel buckets 10 litre capacity 01 No., Plastic bucket 10 litre capacity with Mug 02 No’s each, steel glasses 06 No’s, steel Plates with large spoons and bowls 03 No’s each, Cup and Saucer set (01 No. Set) and, 5kg Gas cylinder with burner/stove. The job also includes providing of thermo-cool 15’x12’ along with excel matting of 15’x12’ size. The job also includes providing of unbreakable Plastic Chair table set consisting of chairs 04 No’s, extra heavy Table 01 No. The job also includes providing of good quality safety Door locks (03 No’s) of Godrej, Link locks |
691 | Providing & Fitting of lighting points in 1.5 mm Sq. multi strand PVC wire as conductor to be laid/carried in PVC channel /conduit as per site requirement. The Job also includes Providing and fitting of 5 Amp. Switch Button /angle holders to be fitted with 15 watt LEDinside the Pump house. |
692 | Providing & fitting of heating points in 2.5 sq. multi stand conductor to be laid & carried in PVC channel/Conduit as per site requirement. The job includes providing and fitting of 16 Amp. Switch socket combine |
693 | Providing and fitting of 18"" sweep seiling fan of standard make including the cost of all cables , connections , , controlsystem along with the speed regulator with control switches for the power supply |
694 | Providing of solar/ electrical lantern chargeable on both solar & electrical 220v supply. |
695 | Providing of bamboo ladders 18 feet long along with 15 feet long Link rods and HT Glove pair (01 No each) |
696 | Providing of 1 KW heat convector for operators for winter season. |
697 | Providing and fitting of 01 No. LED (scroll type) sign board fabricated out of stainless steel and metal showing the names of water supply scheme and the Department.Size:6’×1’6” |
698 | Providing and fitting of 01 No. angle iron/sheet metal board duly painted showing various specifications of the mechanical and electrical equipments installed at site. Size: 4’×6’ out MS ANGLE OF 40X 40X 5of 36 rft and MS sheet of 1 mmthicktotal weight of50.16 kgs |
699 | Illumination of Premises: Providing and erection of 9 Mtr long Hot Dip Galvanized octagonal pole (single Section) with bottom 150mm, top 75mm wide, thickness 3mm with 70 Microns Zinc coating having inside arrangement for providing of power connection along with following items. 1) 3 Way Terminal Connector 20 Amp. 2) 3 No MCB 8 Amp. Rest specification as per cluase "50" of SBD. |
700 | Providing, installation, testing and commissioning of area lighting 120 Watt LED (Street Light Type) on top of octagonal pole vide item No.36 Having following specs: Input: 90-240 V 50 Hz Power Factor: >0.9Colour Temperature: 4K - 6.5KBeam Angle: 120° - 170° Lumens: >12000Operating Temperature: -20°C to 60°C Rest specification as per cluase "51" of SBD. |
701 | Fabrication of gantry mechanism by way of providing Structural steel in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete welded |
702 | Earth work in excavation required for installation ofGantry mechanismand associated worksby manual means in trenches for foundation, drains, pipes, cables (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and reaming of bottom lift upto 1.5 m , including getting out excavated earth and disposal of surplus excavated earth as directed in all kinds of soil. |
703 | Providing and laying of soling stone |
704 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. all work upto plinth level with 1: 2 : 4 (1 cement , 2 coarse sand , 4 graded stone aggregate 20mm nominal size). |
705 | Centering and shuttering including strutting , propping etc. and removal of form work for Foundation, footings, bases for columns |
706 | Painting of the 2 no. gantry and plate form of wellusing one coat of red oxide metal primer and two coats of enamel paintof different shades |
707 | Providing, installation andtestingof manual type triple spur gearchain pulley block along with monorail gearedtravelling trolleyhaving following features Capacity=2 ton (P) No. Of load chain falls = 2 or above Min. Height of lift = 6 M Detailed Techinical specification as per cluase 24 of SBD |
708 | Providing, laying & fixing with adhesive/bonding material of insulation rubber mats on the floor of the pump house, covering area around electro-mechanical machinery for safeguarding the life & limb of the workmen due to possible leakage of current & short circuit. The floor surface shall be made good & shall be free from dust, grease, foreign material & moisture free. The mats shall be as per IS 15652:2006 & shall have the following specifications: - Composition: Rubber (synthetic mats for electrical purpose) Thickness: - 2.5mm Size: - 1M wide. The rubber mats shall be accepted with manufacturers test certificate. |
709 | Providing & Fitting of Dozing pumps to doze required quantity of alum/Chlorine in the system. The capacity of the dozing units shall be 0-12 LPH capacity. Dozing pups shall be provided with all required accessories including 200 ltrs. PVC tanks and cable for connection. Each pump shall be provided with 20 mtrs. cable as per required specification. |
710 | Providing and fitting of pressure gauges with adopters to replace damaged ones .these pressure gauges should be in the range of 0-50 kgf/cm/sg and bereputed make. |
711 | Removal of choked filter media from 5000/ 6000 GPH pressure filter vessel. The job includes all loads and lifts, disposal of choked media to dumping site outside the premises of the plant within a lead of 5 km. The vessel needs to be cleaned properly and dried before laying of fresh media. |
712 | Providing and laying of filter media of specific size and grade to be laid in 5000 GPH Pressure vessels (02 No) duly washed,free from dust ,dirt ,loom and any other inorganic materialor suspension .the job includes carriage of filtermedia from Ganderbalto site including allall loads and liftsrequired on the site condition. The media is to be lad in different layers of specific size and grade from bottom to top over the filter bed plate. The bottom layer is to be laid without tilling/damaging the pressure nozzles. |
713 | Providing and fitting of 12 mm dia. Fine threaded PVC nozzles auxiliary type to be fitted on filter bed plate of pressure vessels (02 Nos). |
714 | Providing and fitting of 29 inch. dia. rubber washers /gaskets for manhole and inspection chamber and opening of pressure filter vessel. |
715 | Providing and fitting of 3”x5/8” nuts and bolts. |
716 | Overhauling of backwash unitof 5000 Pressure vessel (02 No) by way of dismantling of unit parts assembling cleaning, oiling, greasing, replacement of any damaged parts, refining of sub assemblies & installation of backwash unit with its existing suction & delivery outlet. Job includes P/F of packing & consumables. |
717 | Overhauling of air Scavanging/blower unit 5000 GPH Pressure vessel (02 Unit) by way of P/F of reducing pressure weights, filling of oil, replacement of pressure valves. Job includes oiling, greasing & fitting of consumables. |
718 | Painting with synthetic enamel paint two or more coats of approved brand and bar pressure clarifier pressure filter vessel, fittings and complete piping after cleaning of dirt by kerosene oil and application of steel primer of specific grade. |
719 | 26.WSS Tengpora Panzath (Adv. Cost: Rs. 12,15,238/-) |
720 | Supply, Installation, Testing & Commissioning of Submersible Pumping Unit as per IS 8034 with following specification are as under: PUMP: Efficiency = Not less than 50% Speed = 2900 Rpm Type of pump = Mixed flow. Type of fluid to be handled = Clear Water MATERIAL OF CONSTRUCTION: Impeller = Stainless Steel Pump Shaft = Stainless Steel SS 410. Pump Casing Cast Iron/Stainless steel IMPELLER: Impeller is of the enclosed or semi – enclosed type and properly balanced. Enclosed Impellers equipped with seal rings on their hubs. COUPLING: A suitable coupling arrangement provided with pump set. Non Return Valve: - Non Return Valve of the suitable size provided above the pump discharge case. MOTOR:- Method of starting = Star – Delta Speed = 3000 (Sync). Frequency = 50 ± 3 % Hz Working Voltage = 380-415 ± 15% V, 03 phase Efficiency = Not less than 90% Rating = Suitable for above parameters Class of insulation = F/Suitable for above parameters Manufactures Test Certificate to be apended and Detailed specification as per cluase 1 of of SBD Rating: 20 HP |
721 | Fabrication, Providing and fitting of Y- junction having 1m length of each armto be fabricated out ofhot dip galvanized G.I, 100mm dia.C-Class pipe . The job also includes Providing and welding of M.S flanges to the ends of each arm . the Thickness of flange shall conform to IS 6392 Part 1st Table-17. The flange welding shall be carried out in double layers using reputed make electrodes to form strong welding joint by dint of DC arc welding. The job further includes Providing and Fitting of nuts and bolts (conforming to IS:1363 Part 1st) and Rubber Insertion Gaskets (conforming to IS: 638/79) to be used between flanged joints. The |
722 | Providing and fitting of, Ductile Iron double flanged, non-rising spindle soft seated 100mm diameter glandless gate/ sluice valves as per IS14846 for regulating the water supply outside the pumping units. The body and bonnent of the valve shall be of ductileiron, wedge with fully vulcanized EPDM rubber(Approved for drinking water) and NBR seal. The Gate/Sluice valve shall be compatible for buried applications and shall be safe to install in both horizontal and vertical positions. It shall have electrostatic epoxy coating(approved for drinking water) both inside and outside of the valve. The valve shall be supplied along with hand wheel. Cost on account of Nuts, bolts, gaskets, etc required for the job is included in the scope of work. The job includes providing and fitting of 02 nos. M.S flanges perfectly adaptable to the inbuilt flanges of the valve which shall be fitted with rising main of the pumping unit at appropriate spots as per site requirement. Nuts and Bolts Nuts and Bolts (conforming to IS:1363 Part 1st) Rubber Insertion Gaskets Rubber Insertion Gaskets (conforming to IS: 638/79) to be used between flanged joints. |
723 | Providing and fitting ofDuctile Iron double flanged, Slanted seat 100mm diameter swing check valve( NRV) as per IS 5312. The body shall be of ductile cast iron with fully encapsulated vulcanized EPDM rubber(Approved for drinking water). The valve shall be compatible for buried applications and shall be safe to install in both horizontal and vertical positions. It shall have electrostatic epoxy coating (approved for drinking water) both inside and outside of the valve. Cost on account of Nuts, bolts, gaskets, etc required for the job is included in the scope of work. The job includes providing and fitting of 02 nos. M.S flanges perfectly adaptable to the inbuilt flanges of the valve which shall be fitted with Rising main of the pumping unit at appropriate spots as per site requirement. |
724 | Fabrication, Providing and fitting of90-120 degree bend/elbowto be fabricated out of100mm diameter Class-C, G.I pipe, 1 m lengthand flanged on both ends ato make it leak proof. The flanges shall be M.S Flanges conforming to BIS 6392/1997 Table 17 (Rating PN16) and welded on both sides. The job includes nuts, bolts, gaskets etc as per site requirement. |
725 | Fabrication, providing and fitting of washout 100mm dia.Tee with arm length 1.2 feet each. The Tee shall be fabricated out of G.I C-class pipe with M.S Flanges conforming to BIS 6392/1997 Table 17 (Rating PN16) fastened with weld joints on three ends. |
726 | Providing/Fitting& Installation & Testing of , outdoor type100KVA of 11/0.433 KVA , 3 Phase Distribution Transformer with Bimetallic Terminal connectors Energy level -2 Aluminum wound100 KVA Specifications conforming to IS : 1180 (Part 1) 2014 with latest amendments Type of cooling:ONAN. The HT transformer is completely filled with suitable grade transformer oil up to required level. The job includes carriage,and all leads and lifts involved. The HT transformer shall be of reputed make from an ISO certified company as per relevant standards and a test certificate shall be provided before installation. The transformer shall also be provided with breather fill with silica jel crystals , conservator with oil level indicator , explosion vet and adequate radiator fins/ Tubes. The impedance of transformer shall be as per IS:1180 (Part 1) 2014 with latest amendments. NOTE: The scope of the work shall include providing ofnecessary test certificate from the concerned Manufacturer for all the required equipment. |
727 | Providing, fitting, testing and commissioning of 75 KVA voltage stabilizer as per specifications below: Type of voltage controller: Manually operated copper wound, 3-phase, AC power supply multi step. Type of Regulator : Double plate type with electrolytic copper contacts. Input voltage : 250-400 volts.(3 phase) Output voltage : 400 ±10% volts. Frequency : 50 ±3 C/S. Windings : Electrolytic grade copper of adequate section, vacuum impregnated and Rest specification as per cluase "44" of SBD. |
728 | Providing/supplying and fitting of 100 mm diameter G.Iclass B flanged Rising Main at site. The Pipe shall be hot dip Galvanized, class-C confirming to IS 1239. The job includes providing and fitting of M.S Flanges conforming to BIS 6392/1997 Table 17 (Rating PN16). The flanges shall be double welded both from inside and outside of the pipe using standard electrode of reputed make. Flanges (as per IS 6392/1997 Table:17) Thickness shall conform to IS 6392 Part 1st Table-17. The flange welding shall be carried out in double layers using reputed make electrodes to form strong welding joint. Welding Electrode DC Arc Welding using welding electrode having diameter not less than 4mm. Nuts and Bolts Nuts and Bolts (conforming to IS:1363 Part 1st) Rubber Insertion Gaskets Rubber Insertion Gaskets (conforming to IS: 638/79) to be used between flanged joints. The rising main is to be laid as per the instructions of the engineer in charge. |
729 | 27.WSS Gopalpora Kalan (Adv. Cost: Rs. 11,13,182/-) |
730 | Supply, Installation, Testing & Commissioning of Bore Well Submersible Pumping Unit as per IS 8034 with following specification are as under: PUMP: Efficiency = Not less than 50% Speed = 2900 Rpm Type of pump = Mixed flow. Type of fluid to be handled = Clear Water MATERIAL OF CONSTRUCTION: Impeller = Stainless Steel Pump Shaft = Stainless Steel SS Pump Casing Cast Iron/Stainless steel IMPELLER: Impeller is of the enclosed or semi – enclosed type and properly balanced. Enclosed Impellers equipped with seal rings on their hubs. COUPLING: A suitable coupling arrangement provided with pump set. Non Return Valve: - Non Return Valve of the suitable size provided above the pump discharge case. MOTOR:- Method of starting = Star – Delta Speed = 3000 (Sync). Frequency = 50 ± 3 % Hz Working Voltage = 380-415 ± 15% V, 03 phase Efficiency = Not less than 90% Rating = Suitable for above parameters Class of insulation = F/Suitable for above parameters Manufactures Test Certificate to be apended and Detailed specification as per cluase 1 of of SBD Rating: 15 HP |
731 | Fabrication, providing, fitting and lowering of B and C Class column pipe conforming to IS: 1239 of length 10 Rft into the 200/ 250/300 mm casing dia. production well up to the desired depth; The job includes Providing and welding of flanges conforming to IS: 6392, Table-17 and PN 16 to these pipes and welding of flanges in two layers to make the flanged joint strong and leak proof. Size: 80mm Class: B (Medium) Detailed specification as per cluase "7 "of of SBD |
732 | Providing, installation andtestingof manual type triple spur gearchain pulley block along with monorail gearedtravelling trolleyhaving following features Gears:- The hoist shall have precision machine case Hardened alloy steel gear mounted on bearings and housed in a dust proof gear box.The lubrication of gears should be of high viscosity and temperature for longer life of gears. Capacity=2 ton (P) No. Of load chain falls = 2 or above Min. Height of lift = 6 M Rest ofspecification as per Cluase 24 of technical anexure of SBD |
733 | Fabrication, Providing and fitting of20 HP Modularmotor control panel of appropriate size fabricated out of 14 SWG sheet having required openings/vents and protection Class Detailedspecification as percluase 43 d of SBD |
734 | Providing, fitting, testing and commissioning ofvoltage stabilizeras per specifications below: Type of voltage controller: Manually operated copper wound, 3-phase, AC power supply multi step. Type of Regulator: Double plate type with electrolytic copper contacts. Input voltage : 250-400 volts.(3 phase) Output voltage : 400 ±10% volts. Frequency : 50±3 C/S. Rating::50KVA Detailed specification as per cluase 44 of SBD |
735 | Providing and Fitting of 2 core, 3 core, 3.5-Core, XLPE, 1.1KV and 11KV grade Armoured Aluminum Cable of various sizes conforming to IS: 7098 part 1st as service line from the HT transformer to control panel including necessary thimbling, crimping, taping etc. Rest specification as per cluase "71" of SBD. 10 sq mm,2 core AL cable |
736 | 35 sq mm,3.5 core LT Cable |
737 | Providing and fitting of 3-Core flatsubmersible copper cable conforming to IS: 694 (Part 1st) – 1964 & IS: 694 (Part 2nd) - 1964 for Submersible Pumping Unit and other electrical Equipments . The cable connections terminal shall be fitted with copper thimbles of required size. Size: 10 sq.mm |
738 | Providing and Fitting of three/single-Core, copper pvc insulated Cable, XLPE armoured conforming to IS: 7089 part 1st for intedrnal connectionscrimping, taping etc. NOTE:- The cable terminal ends for connection to switchgear at various requisite points shall be Al. Thimbles and of appropriate size and connected by hydraulic crimp tool only. Single core PVC insulated 25sqmm |
739 | Providing, fitting of cable tray of suitable size for carrying the cable inside the machinery room |
740 | P/I of earthing station for substation, LT panel, DG set and stabilizer comprising of company fabricated earthing electrode as per IS: 3043. The job includes Auguring of bore of required dia/depth for installation of electrode along with backfill compound mixed with soil and all other items required thereof for achieving the best result. The job includes connecting of electric gadgets through GI strip as per relevant standards. Safe earthing electrode size:80 mm dia , Length :2000 mm Back fill compound :30 kg |
741 | Providing & fitting of 100A,±10% volts, 50 Hz 04 Pole Change Over Switch in separate SS enclosure. |
742 | IlIllumination of Premises: Providing and erection of 9 Mtr long Hot Dip Galvanized octagonal pole (single Section) with bottom 150mm, top 75mm wide, thickness 3mm with 70 Microns Zinc coating having inside arrangement for providing of power connection along with following items. 1) 3 Way Terminal Connector 20 Amp. 2) 3 No MCB 8 Amp. Rest ofTechnical specification as per Cluase 50of technical anexure of SBD |
743 | Providing, installation, testing and commissioning of area lighting 120 Watt LED (Street Light Type) on top of octagonal pole vide item No.36 Having following specs: Input: 90-240 V 50 Hz Power Factor: >0.9 Colour Temperature: 4K - 6.5K Beam Angle: 120° - 170° Lumens: >12000 Operating Temperature: -20°C to 60°C Rest specification as per cluase "51" of SBD. |
744 | Providing and installation of Junction Box with DP 32 A MCB to serve as Main switch for LED Lighting. The job includes making of electric connection to the circuit. |
745 | Providing, Installation and testing of 2KVA fully automatic voltage stabilizer with input voltage 70-240 V and output 220 V. The stabilizer shall be installed and connected to the electric circuit as per location provided by site in charge. |
746 | Supply, installation, Testing & commissioning of 1000VA Full Sine wave power inverter including Providing / Installation of 12V, 180AH Tubular inverter Battery with trolley and cover. with 2-core 4 mm2 Cu ( 25 m) wiring as per site requirement along with other accessories like SS Combine (02 No’s), 3-pin plugs etc of reputed make for proper fitment and installation of the item. |
747 | Redevelopment of Tube Well |
748 | 28.WSS Dialgam-B (Adv. Cost: Rs. 3,40,491/-) |
749 | Supply, Installation, Testing & Commissioning of Bore Well Submersible Pumping Unit as per IS 8034 with following specification are as under: PUMP: Efficiency = Not less than 50% Speed = 2900 Rpm Type of pump = Mixed flow. Type of fluid to be handled = Clear Water MATERIAL OF CONSTRUCTION: Impeller = Stainless Steel Pump Shaft = Stainless Steel SS Pump Casing Cast Iron/Stainless steel IMPELLER: Impeller is of the enclosed or semi – enclosed type and properly balanced. Enclosed Impellers equipped with seal rings on their hubs. COUPLING: A suitable coupling arrangement provided with pump set. Non Return Valve: - Non Return Valve of the suitable size provided above the pump discharge case. MOTOR:- Method of starting = Star – Delta Speed = 3000 (Sync). Frequency = 50 ± 3 % Hz Working Voltage = 380-415 ± 15% V, 03 phase Efficiency = Not less than 90% Rating = Suitable for above parameters Class of insulation = F/Suitable for above parameters Manufactures Test Certificate to be apended and Detailed specification as per cluase 1 of of SBD Rating: 15 HP |
750 | Fabrication, Providing and fitting of20 HP Modularmotor control panel of appropriate size fabricated out of 14 SWG sheet having required openings/vents and protection Class Detailedspecification as percluase 43 d of SBD |
751 | Providing and fitting of 3-Core flatsubmersible copper cable conforming to IS: 694 (Part 1st) – 1964 & IS: 694 (Part 2nd) - 1964 for Submersible Pumping Unit and other electrical Equipments . The cable connections terminal shall be fitted with copper thimbles of required size. Size: 10 sq.mm |
752 | Providing and Fitting of three/single-Core, copper pvc insulated Cable, XLPE armoured conforming to IS: 7089 part 1st for intedrnal connectionscrimping, taping etc. NOTE:- The cable terminal ends for connection to switchgear at various requisite points shall be Al. Thimbles and of appropriate size and connected by hydraulic crimp tool only. Single core PVC insulated 25sqmm |
753 | 29. WSS Larkipora(Adv. Cost Rs. 28,06,409/-) |
754 | Supply, Installation, Testing & Commissioning of10 HP non clogPumping Unit at Raw Water Stage. PUMP: - Type of pump :Non –clogOpen wellSubmersible Vertical Pump Solid Handling Capacity: 20mm (Minimum) Quality of water:Raw water METERIAL OF CONSTRUCTION: Pump Casing: Cast Iron Impeller : Stainless Steel Pump Shaft: Stainless Steel Motor Body: Cast Iron Sealing :Dual mech. seal The bowl plate shall be provided with name plate depicting all specifications MOTOR: - Type : Squirrel Cage 3-Phase Induction Motor Rating : Suitable for above parameter Method of starting: Star – Delta. Frequency : 50Hz + 3% Voltage: 415± 6 %, -15% Manufacture test certificate to be appended. Rest ofspecification as per Cluase 2of technical anexure of SBD Note: Providing of test certificate & Characteristic Curve of pumping equipment is compulsory and pumping unit is to be approved from the concerned Sub Divisional office before procuring. |
755 | Supply, Installation, Testing & Commissioning ofSubmersible Pumping Unitas per IS 8034 with following specification are as under PUMP : Efficiency = Not less than 50% Speed= 2900 Rpm, Type of pump = Mixed flow. Type of fluid to be handled=Clear Water MATERIAL OF CONSTRUCTION: Impeller= Stainless Steel, Pump Shaft = Stainless Steel SS 410. Pump Casing = Cast Iron/Stainless steel IMPELLER: Impeller is of the enclosed or semi – enclosed type and properly balanced.Enclosed Impellers equipped with seal rings on their hubs. COUPLING: A suitable coupling arrangement provided with pump set. Non Return Valve:- Non Return Valve of the suitable size provided above the pump discharge case. MOTOR:- Method ofstarting = Star – Delta, Speed = 3000 (Sync). Frequency= 50 ± 3 % Hz Working Voltage= 380-415 ± 15% V, 03 phase Efficiency = Not less than 90% Class of insulation=F/Suitable for above parameters Manufacture test certificate to be appended. Rest ofspecification as per Cluase 1of technical anexure of SBD Note: Providing of test certificate & Characteristic Curve of pumping equipment is compulsory and pumping unit is to be approved from the concerned Sub Divisional office before procuring. Rating: 10 H.P |
756 | Rating: 12.5 H.P |
757 | Rating: 15 H.P |
758 | Providing/supplying and fitting ofG.I flanged Rising Main at site. The Pipe shall be hot dip Galvanized, class-C confirming to IS 1239. The job includes providing and fitting of M.S Flanges conforming to BIS 6392/1997 Table 17 (Rating PN16). The flanges shall be double welded both from inside and outside of the pipe using standard electrode of reputed make. Flanges (as per IS 6392/1997 Table:17) Thickness shall conform to IS 6392 Part 1st Table-17. T Class: C (Heavy). Size:DN 100 Manufacture test certificate to be appended. Rest ofspecification as per Cluase 8 of technical anexure of SBD |
759 | Size:DN 80 |
760 | Fabrication ,Providing and fitting of long radiusbend/elbowto be fabricated out ofG.I pipe,and flanged on both ends ato make it leak proof. The flanges shall be M.S Flanges conforming to BIS 6392/1997 Table 17 (Rating PN16) and welded on both sides. The job includes nuts, bolts, gaskets etc as per site requirement. Class: C Size:DN 100 |
761 | Size:DN 80 |
762 | Fabrication, providing and fitting of washout Tee with arm length 1.2 feet each. The Tee shall be fabricated out of G.I pipe with M.S Flanges conforming to BIS 6392/1997 Table 17 (Rating PN16) fastened with weld joints on three ends. Class: C class Size: 100mm |
763 | Size: 80mm |
764 | Providing and fitting of, Ductile Iron double flanged, non-rising spindle soft seatedglandless gate/ sluice valves as per IS14846 for regulating the water supply outside the pumping units PN:1.6/16 Size: DN100 Manufacture test certificate to be appended. Rest ofspecification as per Cluase 12of technical anexure of SBD |
765 | Size :DN80 |
766 | Providing and fitting ofDuctile Iron double flanged, Slanted seatswing check valve (NRV) as per IS 5312. PN: 1.6/16 Size: DN100 Manufacture test certificate to be appended. Rest ofspecification as per Cluase 13of technical anexure of SBD |
767 | Size: DN80 |
768 | Creation of polemounted , outdoor type Electric Sub Stationby way ofS/I/T/C of 11/0.433 KVA, 3 Phase Distribution Transformer with Bimetallic Terminal connectors Energy level -2 Aluminum wound Specifications conforming to IS : 1180 (Part 1) 2014 with latest amendments Type of cooling:ONAN. Rating: 100 KVA HT Transformer, 3 phase (Level 2). Manufacture test certificate to be appended. Rest ofspecification as per Cluase 26 of technical anexure of SBD |
769 | Providing and fitting of LT Distribution box for HT transformer with MCCB 200 Amp For incomer and SFU for out going circuits . Capacity of transformer: 100 KVA |
770 | Fabrication of gantry mechanism by way of providing Structural steel in built up sections, trusses and framed work, including cutting , hoisting , fixing in position and applying a priming coat of approved steel primer all complete welded |
771 | Providing, installation andtestingof manual type triple spur gearchain pulley block along with monorail gearedtravelling trolleyhaving following features. Gears:- The hoist shall have precision machine case Hardened alloy steel gear mounted on bearings and housed in a dust proof gear box. The lubrication of gears should be of high viscosity and temperature for longer life of gears. Load Chain:-The load chain be made of high tensile alloy steel having wear resistance and greatest mobility Capacity = 2 ton No. Of load chain falls= 2 or above Min. Height of lift= 6 M Rest ofspecification as per Cluase 24 of technical anexure of SBD |
772 | Supply, Installation, Testing and commissioning of Polymeric Gang operated Air break switch, outdoor type, triple pole, suitable for vertical installation, single break provided with locking arrangement at both ON and OFF position consisting ofHT post double insulator, copper or copper alloy high pressure heavy contact assembly, rod with bearings , operating handle and 2 length of 32mm dia. GI pipe conforming to IS 1818 1961, 06 No. of insulators, rated voltage 11KV 200A complete as per IS specs. |
773 | Supply, Installation, Testing and commissioning of 11KVpolymer fuses SetHorn Gap3-phase 200 Asuitable for vertical installation . |
774 | Supply, Installation, Testing and commissioning ofGapless Surgearrestor station class, 10KA, 9KV, LA With polymer housing , Station Type . |
775 | Providing and fittingG.I Channel /Angle/ Flat of sizes including clamps |
776 | Providing and fitting of ACSR as per IS 398 (part-2) 1996 for 50 sq.mmACSR (Galvanised steel reinforced) for fitment of various accessories |
777 | Fabrication, Providing and fitting of 20 Modularmotor control panel of appropriate size fabricated out of 14 SWG sheet having required openings/vents and protection Class : IP-55 & fitted with accessories as under: a) Busbar Chamber: 100 Ampres b) Main Circuit Breaker (Incomer MCCB): Qty:-= 01 No Current Rating = 100 Amp. c) Change over Switch: Qty. = 01 No. Rating =100 Ampere d) Motor Back-up Protection MCCB: Qnty = 2 No’s Current Rating= 100 A e) Submersible Motor starter: Fully automatic submersible motor starters. Rating = 20 HP Power Specs =3 ?, 415 + 15% V, 50 + 3 % Hz. Relay range= 20-32 A. Protection = Under voltage/ over Voltage Qty = 02 No’s f) Auxiliary MCCB for Heating/Lighting: Circuit Breaker = MCCB (Outgoing) Qty.= 1 No., Current Rating= 63 Amp. Rest of the specicifications are as per clause-43 ofTechnical annexure of SBD |
778 | Fabrication, Providing and fitting of 30 Modularmotor control panel of appropriate size fabricated out of 14 SWG sheet having required openings/vents and protection Class : IP-55 & fitted with accessories as under: a) Busbar Chamber: 100 Ampres b) Main Circuit Breaker (Incomer MCCB): Qty:-= 01 No Current Rating = 200 Amp. c) Change over Switch: Qty. = 01 No. Rating =100 Ampere d) Motor Back-up Protection MCCB: Qnty = 2 No’s Current Rating= 100-125Amp 36 KA e) Submersible Motor starter: Fully automatic submersible motor starters. Rating = 30 HP Power Specs =3 ?, 415 + 15% V, 50 + 3 % Hz. Relay range= 30-50 A. Protection = Under voltage/ over Voltage Qty = 02 No’s f) Auxiliary MCCB for Heating/Lighting: Circuit Breaker = MCCB (Outgoing) Qty.= 1 No. Current Rating= 63 Amp. Rest of the specicifications are as per clause-43 ofTechnical annexure of SBD |
779 | Providing, fitting, testing and commissioning ofvoltage stabilizeras per specifications below: Type of voltage controller: Manually operated copper wound, 3-phase, AC power supply multi step. Type of Regulator: Double plate type with electrolytic copper contacts. Input voltage : 175-400 volts.(3 phase) Output voltage : 400 ±10% volts. Frequency : 50±3 C/S. Windings : Electrolytic grade copper of adequate section, vacuum impregnated and Oven-dried. Insulation : Fiber glass insulations to tested parameters. Cooling: Naturally, Oil cooled Temp. Rise (Max) : 30°C above ambient Mounting : On Uni-directional wheels. Correction rate : 30 volts per step Wave form distortion: virtually nil Duty cycle : 100% continuous. Enclosure : MS sheet enclosure in pressed CGR Sheet powder coated with radiators. Core laminates: High grade, low eddy loss, grain oriented silicon steel laminations. Load: Three phase induction motor load. Load Amperes (continuous) Rating::50KVA Rest ofTechnical specification as per Cluase 45 of technical anexure of SBD |
780 | Providing and Fitting of 3 /3.5/2-Core, XLPE Armoured Aluminium Cable conforming to IS: 7089 part 1st as service line from the HT transformer to control panel including necessary thimbling, crimping, taping etc. NOTE:- The cable terminal ends for connection to switchgear at various requisite points shall be Al. Thimbles of dowel’s make and of appropriate size and connected by hydraulic crimp tool only. i) 50 sqmm, 3.5core |
781 | ii) 10 sqmm, 2 core |
782 | Providing and fitting of 3-Core flatsubmersible copper cable conforming to IS: 694 (Part 1st) – 1964 & IS: 694 (Part 2nd) - 1964 for Submersible Pumping Unit and other electrical Equipments . The cable connections terminal shall be fitted with copper thimbles of required size. Size: 25 sq mm |
783 | Size: 16 sq mm |
784 | Illumination of Premises: Providing and erection of 9 Mtr long Hot Dip Galvanized octagonal pole (single Section) with bottom 150mm, top 75mm wide, thickness 3mm with 70 Microns Zinc coating having inside arrangement for providing of power connection along with following items. 1) 3 Way Terminal Connector 20 Amp. 2) 3 No MCB 8 Amp. Rest of the specicifications are as per clause-51 ofTechnical annexure of SBD |
785 | Providing, installation, testing and commissioning of area lighting 120 Watt LED (Street Light Type) on top of octagonal pole vide item No.36 Having following specs: Input: 90-240 V 50 Hz Power Factor: >0.9 Colour Temperature: 4K - 6.5K Beam Angle: 120° - 170° Lumens: >12000 Operating Temperature: -20°C to 60°C Rest of the specicifications are as per clause-52 ofTechnical annexure of SBD. |
786 | Providing, Installation and testing of 2KVA fully automatic voltage stabilizer with input voltage 70-240 V and output 220 V. The stabilizer shall be installed and connected to the electric circuit as per location provided by site incharge. |
787 | Providing, laying & fixing with adhesive/bonding material of insulation rubber mats on the floor of the pump house, covering area around electro-mechanical machinery for safeguarding the life & limb of the workmen due to possible leakage of current & short circuit. The floor surface shall be made good & shall be free from dust, grease, foreign material & moisture free. The mats shall be as per IS 15652:2006 & shall have the following specifications: - Composition: Rubber (synthetic mats for electrical purpose) Thickness: - 2.5mm Size: - 1M wide. The rubber mats shall be accepted with manufacturers test certificate. |
788 | Providing of solar/ electrical lantern chargeable on both solar & electrical 220v supply. |
789 | Removal of choked filter media from 5000/ 6000 GPH pressure filter vessel. The job includes all loads and lifts, disposal of choked media to dumping site outside the premises of the plant within a lead of 5 km. The vessel needs to be cleaned properly and dried before laying of fresh media. |
790 | Providing and layingof filter media of specific size and grade (preferably from sindh Nallah Ganderbal) to be laid in 5000/6000 GPH Pressure vessel duly washed, free from dust, dirt, loom and any other inorganic material or suspension, the job includes carriage of filter media from Ganderbalto site including allall loads and liftsrequired on the site condition. The media is to be lad in different layers of specific size and grade from bottom to top over the filter bed plate. The bottom layer is to be laid without tilling/damaging the pressure nozzles |
791 | Providing and fitting of 12 mm dia. Fine threaded PVC nozzles auxiliary type to be fitted on filter bed plate of pressure vessel. |
792 | Providing and fitting of suitable sizerubber washers /gaskets for manhole and inspection chamber and opening of pressure filter vessel. |
793 | Providing and fitting of suitable sizenuts and bolts. |
794 | P/I/T/C of backwash pumping equipment of following parameters Discharge-16 lpsHP-5, Head range 6-15mtr |
795 | Painting with synthetic enamel paint two or more coats of approved brand and bor pressure clarifier pressure filter vessel, fittings and complete piping after cleaning of dirt by kerosene oil and application of steel primer of specific grade. |
796 | P/I/T/C of horizontal monoblock pumping equipment of following parameters; a) Discharge :-6000GPH, b) Head: 30 meters. c) Speed: 1440 rpmThe pump & motor should be mounted on a suitable size MS base frame. The Job also includes P/F of foundation bolts |
797 | P/I/T/C of air scavenging/blower unit of following parameters Capacity: -50 CFM, Pressure: -5PS10, Speed: - 1450 RPM Motor HP- |
798 | Providing, fabrication and fitting of welded MS wire mesh (0.50 sq. inch and 1.40mm wire dia. for Bird screening to the CGI Pressure Filter House. |
799 | Replacement of 25 mm dia. -03 No’s (Ball Valves-Reputed make) The job includes providing and fitting of nuts and bolts and washers with allied mechanical works. The job includes Providing, fitting of25mm dia. GI-6 mtrs with necessary fittings as per requirement. |
800 | Replacement of 80 mm dia cast iron diaphram valves by way of including fresh DI gate /Butterfly valves with pressure rating of PN16 |
801 | Replacement of 65 mm Butterfly valvesof PN16 |
802 | P/I/T/of5 H.P. DOL |
803 | Providing and fitting of 50 mm NRV |
804 | P/F/Welding of 50 mm flanges to the existing piping system after cutting the damaged ones. |
805 | Providing and fitting of pressure gauges with adopters to replace damaged ones these pressure gauges should be in the range of 0-50 kgf/cm/sg and be reputed make. |
806 | Providing and fitting of Dozing pumps to be doze required quantity of alum /chlorine in the system .The capacity of the dozing units shall be 12-20 LPH capaicity withh all acessories |
807 | 30. WSS Gujjar Basti Shangus (Adv. Cost Rs. 37,55,440/-) |
808 | Supply, Installation, Testing & Commissioning of Openwell Horizontal Submersible Pumping Unitas per IS 14220for with following specification are as under : PUMP : Discharge Range = 2000- 4000 GPH Head Range= 65-72 mtrs Efficiency = Not less than 50% Speed= 2900 Rpm Type of pump = Open Well HorizontalSubmersible Pump Type of fluid to be handled=Clear Water MOTOR:- Motor Rating= 7.50 HP/ as per OEM Method ofstarting = Star – Delta Speed = 3000 (Sync). Frequency= 50 ± 3 % Hz Working Voltage= 380-415 ± 15% V, 03 phase Efficiency = Not less than 90% Class of insulation=F/Suitable for above parameters Rest of Specification/Details are as per clause 3 of SBD Note. Since the source has not been identifiedas yet , as such the above parametres have been assumed and may vary at the time of execution of works depending upon the actual well parametres obtained after identification of Source. |
809 | Fabrication, providing, fitting and lowering ofcolumn pipe conforming to IS: 1239 of length 10 Rft into the 200/ 250/300 mm casing dia. production well up to the desired depth ; The job includes Providing and welding of flanges conforming toIS: 6392, Table-17 and PN 16 Size: DN 65 Class: B (Medium) Rest of Specification/Details areas per clause 7 of SBD |
810 | Providing/supplying and fitting ofG.I flanged Rising Main at site. The Pipe shall be hot dip Galvanized, class-B confirming to IS 1239. The job includes providing and fitting of M.S Flanges conforming to BIS 6392/1997 Table 17 (Rating PN16). Size: DN 65 Class: B (Medium) Rest of Specification as per clause 8 of SBD |
811 | Earth work in excavation by manual means in trenches for foundation, drains, pipes, cables (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and reaming of bottom lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed. (All kinds of soil 01 meter from cutting edge) |
812 | Filling available excavated earth in trenches, plinth, sides of foundation etc.in layers not exceeding 20 cm in depth, consolidating each deposited layer by reaming and watering, lead upto 50 m and lift upto 1.5m. |
813 | Providing and laying hand packed stone soling 50 mm nominal size including filling, spreading, dressing,ramming, all leads lifts and all carriages complete. |
814 | Centering and shuttering including strutting , propping etc. and removal of form work for Foundation, footings, bases for columns |
815 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering . all work upto plinth level with 1 : 2 : 4 mix (1 cement , 2 coarse sand , 4 graded stone aggregate 20mm nominal size) |
816 | Fabrication, providing and fitting of washout Tee with arm length 1.2 feet each. The Tee shall be fabricated out of G.I pipe with M.S Flanges conforming to BIS 6392/1997 Table 17 (Rating PN16) fastened with weld joints on three ends. Size: DN 65 Class: C Heavy Rest of Specification/Details areas per clause 09 of SBD |
817 | Providing and fitting of, Ductile Iron double flanged, non-rising spindle soft seatedglandless gate/ sluice valves as per IS14846 for regulating the water supply outside the pumping units . Size: DN65 PN:1.6/16 Rest of Specification/Details areas per clause 12 of SBD |
818 | Providing and fitting ofDuctile Iron double flanged, Slanted seatswing check valve( NRV) as per IS 5312. Size: 65 mm PN: 1.6/16 Rest of Specification/Details areas per clause 13 of SBD |
819 | Providing, fitting, testing and commissioning of ARV (Air Release valve) as per IS 14845 to be fitted to G.I rising Main. Size: 50mm PN: 1.6/16 Rest of Specification/Details areas per clause 14 of SBD |
820 | Fabrication ,Providing and fitting of90-120 degree bend/elbowto be fabricated out ofG.I pipe, 1 m lengthand flanged on both ends ato make it leak proof. The flanges shall be M.S Flanges conforming to BIS 6392/1997 Table 17 (Rating PN16) and welded on both sides. The job includes nuts, bolts, gaskets etc as per site requirement. Size:DN 65 Rest of Specification/Details areas per clause 15 of SBD |
821 | Fabrication, providing and fitting of split type MS clamps10 mm thick, 2 ft long and 3 inch wide for lowering and holding of pumping unit fitted. The job includes the cost of required size of nuts and bolts. Size: 65 mm Rest of Specification/Details areas per clause 16 of SBD |
822 | Fabrication of gantry mechanism/CGI Shed by way of providing Structural steel in built up sections , trusses and framed work, including cutting , hoisting , fixing in position and applying a priming coat of steel primer and 02 coats of paint of approved shade all complete welded. The drawings and Dimensions for Gantry/CGI Shedwill be provided by Site In Charge at the time of execution of job Rest of Specification/Details areas per clause 21 of SBD |
823 | Providing and fitting ofM.S 4 inch hinges -6 no and M.S handle heavy -2no., Anchor bolts with nuts (M16) of 0.3 m long= 04 No. Metallic strip (350mm×50mm×3mm) = 02 No. Rest of Specification/Details areas per clause 23 of SBD |
824 | Supply, Installation and testing of manual type triple gear chain pulley block along with mnrail geared travelling trolley y of proper specifications Capacity =2 ton Rest of specification as per cluase 24 of SBD |
825 | Creation of pole mounted , outdoor type Electric Sub Stationby way ofS/I/T/C of 11/0.433 KVA , 3 Phase Distribution Transformer with Bimetallic Terminal connectors Energy level -2 Aluminum wound Specifications conforming to IS : 1180 (Part 1) 2014 with latest amendments Type of cooling:ONAN. Rating: 25 KVA HT Transformer, 3 phase (Level 2). Manufacturers certificate be apended and rest of specification as per cluase 26 of SBD |
826 | Providing and fittingG.I Channel /Angle/ Flat of sizes including clampsas per details in Clause 27 of SBD |
827 | Supply, Installation, Testing and commissioning of Polymeric Gang operated Air break switch, outdoor type, triple pole, suitable for vertical installation, complete as per IS specs Rest of Specification/Details areas per clause 28 of SBD |
828 | Supply, Installation, Testing and commissioning of 11KVpolymer fuses SetHorn Gapas per details in Clause 29 of SBD |
829 | Supply, Installation, Testing and commissioning ofGapless Surgearrestor station class as per details in Clause 30 of SBD |
830 | Supply and fitting of 11 KV polymeric composite pin insulator as per details in Clause 31 of SBD |
831 | Supply, installation, errection of9 mtrs long H.T pole of specifications ST- 410 (sp-33) as per details in Clause 32 ofSBD |
832 | P/F of Galvanized nuts, bolts of various sizes as per site requirement.as per details in Clause 33 ofSBD |
833 | P/F Danger Plate with clamps as per details in Clause 34 ofSBD |
834 | Providing and fixing G.I Barbed wire for anti climbing/ anti climbing devices with clamps as per details in Clause 35 ofSBD |
835 | Providing and Fitting of PG clamps |
836 | Providing and fitting of Galvanized stay set complete as per details in Clause 36 ofSBD |
837 | Painting of poles Red oxide |
838 | Painting of poles Aluminum paint |
839 | Providing and fitting of ACSR as per details in Clause 39 ofSBD |
840 | Supply, Installation and Testing of 35 Sq mm XLPE Aluminum H.Tcable (ABC type ) of 11 KV grade with following specs. Size (cross sectional area in sq mm) = 3×35 with reinforced wire Phases:Red, Yellow, Blue |
841 | Providing and fitting of Anchoring clampsrequired for holding of 3 – Core , 35 Sq. mm H.T AB Cable as per details in Clause 40 ofSBD |
842 | P/F of 11 KV cable termination kit as per details in Clause41 ofSBD |
843 | Providing and fitting of LT Distribution box for HT transformer Capacity of transformer: 25 KVA Rest of Deatils/Technical specification are as per clause 42 ofSBD |
844 | Providing and fitting of PRODIGY LT Metre of following specification complete with all fixturesrequired for fitment at site Type: E3L100, 3 Phase, 4 wire Measurements offered: KWh,KVARh,KVAh,KVA Voltage : 3x240V(415v),50HZ Ib : 40A Imax: 200A Battery: Lithium |
845 | Fabrication Providing and fitting of modular control panel of appropriate size fabricated out of 14SWG sheet having required openings/vents and protection class: IP-55 and fitted with accessories MU-G15 and Rest of Deatils/Technical specification are as per clause 43 (c) ofSBD |
846 | Providing, fitting, testing and commissioning ofManually operated copper wound, 3-phase, AC power supply multi step voltage stabilizer. Rating::25 KVA Manufacturers test certificate to be apended and rest of specification as per clause 44 of SBD. |
847 | Providing and Fitting of 3 /3.5/2-Core, XLPE Armoured Aluminium Cable conforming to IS: 7089 part 1st as service line from the HT transformer to control as per clause 45 of SBD. i) 35 sqmm, 3.5core, LTcable |
848 | Providing and Fitting of 3 /3.5/2-Core, XLPE Armoured Aluminium Cable conforming to IS: 7089 part 1st as service line from the HT transformer to control as per clause 45 of SBD. ii) 10 sqmm, 2 core, LTcable |
849 | Providing and fitting of 3-Core flatsubmersible copper cable conforming to IS: 694 (Part 1st) – 1964 & IS: 694 (Part 2nd) - 1964as per details in Clause 47 ofSBD Size: 10 sq.mm |
850 | Providing and fitting of 25 mm square single core copper cable for interconnecting various electrical gadets as per IS 694: 2010 along with thimbling as per requirement. |
851 | Providing and Fitting ofcable tray of suitable size for carrying the cable inside the machinery room. |
852 | P/I of earthing station for substation, LT panel, DG set and stabilizer comprising of company fabricated earthing electrode as per IS: 3043. Rest of Specifications/details are as per specification in clause 48 of SBD |
853 | Supply, installation of 6 kg co2 type fire extinguisher manufactured as per IS:15683 OF 2006 with IS mark and comply with DGMS(Approval) . Rest of details as per specification in clause 49 of SBD |
854 | Illumination of Premises: Providing and erection of 9 Mtr long Hot Dip Galvanized octagonal pole (single Section) with bottom 150mm, top 75mm wide, thickness 3mm with 70 Microns Zinc coating having inside arrangement for providing of power connection along with following items. 1) 3 Way Terminal Connector 20 Amp. 2) 3 No MCB 8 Amp. Rest of Deatils/Technical specification are as per clause 50 ofSBD |
855 | Providing, installation, testing and commissioning of area lighting 120 Watt LED (Street Light Type) on top of octagonal pole Having following specs: Input: 90-240 V 50 Hz Power Factor: >0.9 Rest of Deatils/Technical specification are as per clause 51 of SBD |
856 | Providing and installation of Junction Box with DP 32Amp MCB to serve as amin switch for LED lighting. Rest of Deatils/Technical specification are as per clause 52 of SBD |
857 | Providing, Installation and testing of 2KVA fully automatic voltage stabilizer Rest of Deatils/Technical specification are as per clause 53 of SBD |
858 | Supply, installation, Testing & commissioning of 1000VA Full Sine wave power inverter with 12V, 180AH Tubular inverter Battery Rest of Deatils/Technical specification are as per clause 54 of SBD |
859 | Providing, laying & fixing with adhesive/bonding material of insulation rubber mats on the floor of the pump house, covering area around electro-mechanical machinery for safeguarding the life & limb of the workmen . Rest of Deatils/Technical specification are as per clause 55 of SBD |
860 | TOOL KIT For Maintenance: - The Tool Kit for maintenance as per detailed specification in cluase 56 of SBD |
861 | Providing of good quality conveinence and utility items as per details in Caluse57 of SBD |
862 | Fabricationof7’ (L) x 6’(B) x 1.5" (H) angle iron bedfor operators withback-height of 2 feet. The detailed drawing will be provided by site incharge. Rest of Deatils/Technical specification are as per clause 58 of SBD |
863 | Providing and fitting of 19 mm thick multilayered ply sheet of size 6 x 3 feet , 3 nos. Rest of Details/Technical specification are as per clause 59 of SBD |
864 | Providing of solar/ electrical lantern chargeable on both solar & electrical 220v supply. |
865 | Providing of bamboo ladders 18 feet long along with 15 feet long Link rods and HT Glove pair (01 No each) |
866 | Providing of 1 KW heat convector for operators for winter season. |
867 | Providing and fitting of 01 No. LED (scroll type) sign board fabricated out of stainless steel and metal Rest of Deatils/Technical specification are as per clause 63 of SBD |
868 | Providing and fitting of 01 No. angle iron/sheet metal board duly painted showing various specifications of the mechanical and electrical equipments installed at site size= 7x5 feet Rest of Deatils/Technical specification are as per clause 64 of SBD |
869 | Providing, installation, Testing & commissioning of 415 ±10%V (output), 3 phase Diesel Generator set as per IS 8528 (2018) and ISO 3046 (2002) for engine and IEC/IS 60034-1 for alternator suitably assembled and fitted in a pollution free acoustic enclosure / canopy of required size as per Ministry of Environment protection rule 1986 read with latest amendments. Rating: 15 KVA , Air Cooled Manufacturers certifice to be apended and rest of specification as per cluase 66 of SBD |
870 | Providing and fitting of L.T35 Sq. mm , 1core , capable to work upto 1.1 KV, XLPE insulated , galvanized steel strip armoured coppercableconforming to IS : 7089(part -1) 1988 With latest amendmentsto be fitted fromD.G Setto Modular control panel Rest of Deatils/Technical specification are as per clause 67 of SBD |
871 | Providing corrugated G.S Sheet roofingand on the all sides of DG Set shed including vertical/ curved surface fixed with polymer coated J or L Hooks , bolts and nuts Rest of Deatils/Technical specification are as per clause 68 of SBD |
872 | Providing, Installation, Testing & Commissioning of complete switchgear unit for protection of D.G Setconsisting of 200A MCCB 3- pole , 415 V, 50 KV breaking capacity Rest of Deatils/Technical specification are as per clause 78 of SBD |
873 | Carriage of sand, stone aggregate by mechanical transportincluding loading, unloadingand stacking (average distance-5km) Rest of Deatils/Technical specification are as per clause 79 of SBD |
874 | 31. (Part A) WSS Express Highway Part A (Checki Wangund SR) (Adv. Cost Rs. 26,53,960/-) |
875 | Supply, Installation, Testing & Commissioning of Open Well Pumping Units as per 14220 at Filter Water Stage. PUMP: - Discharge 12000 GPH Head 38 mtrs• Type of pump:Open well Horizontal Submersible Pump• Quality of Water to be handled : Filter waterMETERIAL OF CONSTRUCTION:• Pump Casing : Cast Iron • Impeller :SS • Pump Shaft : Stainless Steel • Motor Body : Cast Iron• Sealing: Dual mech. seal The bowl plate shall be provided with name plate giving complete specifications.MOTOR: -Rating : Suitable for above parameter • Method of starting: Star – Delta. Frequency : 15 Hz + 3% : voltage , 415+6% -15% Class of insulation suitable for above rating , Sealing dual Mech. Manufacturers test certificate to be appended and detailed specification as per clause(3 of SBD) 15 HP |
876 | Fabrication, providing, fitting and lowering of B Class column pipe conforming to IS: 1239 of length 10 Rft into the 200/ 250/300 mm casing dia. production well up to the desired depth; The job includes Providing and welding of flanges conforming to IS: 6392, Table-17 and PN 16 to these pipes and welding of flanges in two layers to make the flanged joint strong and leak proof. Detailed specification as per cluase "7 "ofof SBD 100 mm |
877 | Providing/supplying and fitting of G.I flanged Rising Main at site. The Pipe shall be hot dip Galvanized, class B and C confirming to IS 1239. The job includes providing and fitting of M.S Flanges conforming to BIS 6392/1997 Table 17 (Rating PN16). The flanges shall be double welded both from inside and outside of the pipe using standard electrode of reputed make.Flanges (as per IS 6392/1997 Table:17) Thickness shall conform to IS 6392 Part 1st Table-17. Detailed specification as per cluase "8" ofof SBD 125 mm |
878 | Earth work in excavation by manual means in trenches for foundation, drains, pipes, cables (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan , including dressing of sides and reaming of bottom lift upto 1.5 m , including getting out excavated earth and disposal of surplus excavated earth as directed:(All kinds of soil 01 meter from cutting edge) |
879 | Filling available excavated earth in trenches, plinth, sides of foundation etc.in layers not exceeding 20 cm in depth , consolidating each deposited layer by reaming and watering , lead upto 50 m and lift upto 1.5m.Quantity : 90% of item no: 04 |
880 | Fabrication, providing and fitting of split type MS clamps10 mm thick, 2 ft long and 3 inch wide for lowering and holding of pumping unit fitted with 100 mm dia column pipe. The job includes the cost of required size of nuts and bolts. (02 Pair) 100 MM |
881 | Fabrication, Providing and fitting of Y- junction having 1m length of each arm to be fabricated out of hot dip galvanized G.I, C-Class pipe. The job also includes Providing and welding of M.S flanges to the ends of each arm. TheThickness of flange shall conform to IS 6392 Part 1st Table-17. Rest specification as per cluase "10"of SBD. 125 C Heavy |
882 | Fabrication, providing, fitting long raduisbendout of 1 mtr of pipe with length of1 ft each arm The job includes all types of skilled labours, arrangement of power supply/ diesel Generator set etc required for the job including P/F of suitable size nuts bolts and R.I Gasket in the flanged joints. Rest specification as per cluase "15"of SBD 125 MM |
883 | Cutting of hot dip galvanized G.I, C-Class pipe across the section by dint of pipe cutter/ gas cutter. The job also includes Providing and welding of M.S flanges to the two ends of pipe. The Thickness of flange shall conform to IS 6392 Part 1st Table-17. :Rest specification as per cluase "11"of SBD. 125 MM |
884 | Fabrication, providing, fitting T- junction out of 1 mtr of pipe with length of1 ft each arm The job includes all types of skilled labours, arrangement of power supply/ diesel Generator set etc required for the job including P/F of suitable size nuts bolts and R.I Gasket in the flanged jointsRest specification as per cluase "09"of SBD 125 MM |
885 | Providing and fitting of, Ductile Iron double flanged, non-rising spindle soft seated glandless gate/sluice valves as per IS14846 for regulating the water supply outside the pumping units . The body and bonnent of the valve shall be of ductileiron, wedge with fully vulcanized EPDM rubber(Approved for drinking water) and NBR seal. The Gate/Sluice valve shall be compatible for buried applications and shall be safe to install in both horizontal and vertical positions Rest specification as per cluase "12"of SBD. 125 MM |
886 | Providing and fitting ofDuctile Iron double flanged, Slanted seat swing check valve (NRV) as per IS 5312. The body shall be of ductile cast iron with fully encapsulated vulcanized EPDM rubber (Approved for drinking water). Rest specification as per cluase "13"of SBD. 125 MM |
887 | Providing, fitting, testing and commissioning of ARV (Air Release valve) as per IS 14845 to be fitted to G.I risingMain. The ARV Shall have the following specifications: i. Valve type - single chamber, single orifice. ii. End connection-flanged ends to IS 1538 iii. Working temperature 70o c to 550 c iv. Test pressure - body/seat 2.5 x PNv. Sealing ring - EPDM vi. Construction - ductile iron with stainless steel floats ii. Coating - epoxy with corrosion resistance Rest specification as per cluase "14"of SBD. 50 MM |
888 | Fabrication, Providing and fitting ofModularmotor control panel of appropriate size fabricated out of 14 SWG sheet having required openings/vents and protection Class : IP-55 & fitted with accessories MU-G 20 Rest specification as per cluase "43 ____"of SBD. |
889 | Design , supply , installation , testing and commissioning of automatic power factor correctionpanel for improvement of power factor (Suitable for 10-15 HP motor rating) as per details given below: |
890 | Providing, fitting, testing and commissioning ofvoltage stabilizeras per specifications below: Type of voltage controller: Manually operated copper wound, 3-phase, AC power supply multi step. Type of Regulator: Double plate type with electrolytic copper contacts. Input voltage : 250-400 volts.(3 phase) Output voltage : 400 ±10% volts. Frequency : 50 ±3 C/S. Windings : Electrolytic grade copper of adequate section, vacuum impregnated and Rest specification as per cluase "44"of SBD. Rating: 50 KVA |
891 | Providing and Fitting of 2 core, 3 core, 3.5-Core, XLPE, 1.1KV and 11KV grade Armoured 50sqmm, 3.5 core L.T 1.1 Kv |
892 | Providing and fitting of 3-Core flat submersible copper cable conforming to IS: 694 (Part 1st) –1964 & IS: 694 (Part 2nd) - 1964 for Submersible Pumping Unit and other electrical Equipment. The cable connections terminal shall be fitted with copper thimbles of required size. The main specification of the cable is given below:Rest specification as per cluase "47"of SBD. 10 Sq.mm |
893 | P/I of earthing station for electric substation, LT panel and stabilizer comprising of company fabricated earthing electrode as per IS: 3043. The job includes Auguring of bore of required dia/depth for installation of electrode along with backfill compound mixed with soil and all other items required thereof for achieving the best result. The job includes connecting of electric gadgets through GI strip as per relevant standards. Safe earthing electrode size:80 mm dia, Length:2000 mm Back fill compound:30 kg |
894 | Supply, installation of 6 kg CO2 type fire extinguisher manufactured as per IS: 15683of 2006 with IS mark and comply with DGMS (Approval). The co2 extinguisher should be suitable for class B & C fire and also for fire involving electrical equipment. The cylinder used for fire extinguisher shall be approved by petroleum and explosive safety organization (PESO) as per gas cylinder rules 2004 and as per IS: 7285 of 2004. The body should be made of seamless steel (manganese) confirming to IS: 7285 with IS mark and should be provided with squeeze grip nozzle and should be filled with co2 confirming to IS: 15222 of 2002 with certificate.The extinguisher shall be provided with manufactures test certificate and hydraulic test certificate by BIS from PESO. |
895 | Providing and fitting ofPVC iinsulated copper cable as per IS 694-along with thimbling as per requirmentsRest specification as per cluase "67 "of SBD. Size: 16 sq.mm1 core LT 1.1KV |
896 | Supply, installation, Testing & commissioning of 1000VA Full Sine wave power inverter including Providing / Installation of 12V, 180AH Tubular inverter Battery with trolley and cover. with 2core 4 mm 2 Cu ( 25 m) wiring as per site requirement along with other accessories like SS- Combine (02 No’s), 3-pin plugs etc of reputed make for proper fitment and installation of the item. |
897 | Providing, laying & fixing with adhesive/bonding material of insulation rubber mats on the floor of the pump house, covering area around electro-mechanical machinery for safeguarding the life & limb of the workmen due to possible leakage of current & short circuit. The floor surface shall be made good & shall be free from dust, grease, foreign material & moisture free. The mats shall be as per IS 15652:2006 & shall have the following specifications: Composition: Rubber (synthetic mats for electrical purpose) Thickness: - 2.5mm Size: - 1M wide. The rubber mats shall be accepted with manufacturers test certificate. |
898 | TOOL KIT For Maintenance: -The Tool Kit for maintenance shall comprise of the following and all the items as mentioned below shall be ofProviding of tool kit consists of following items i. Double ended Spanner(Chrome plated)As per SBD |
899 | Fabricationof6’ x 6’ angle iron bed by way of providingand fitting of Structural steel in built up sections , trusses and framed work, including cutting , hoisting , fixing in position and applying a priming coat of approved steel primer all complete welded |
900 | Providing and fitting of 19 mm thick multilayered ply sheet of size 6 x 3 feet , 2 no’s including cutting , fixingall complete including painting of the play sheet by one coat of primer and two coats of enamel paint |
901 | a) Providing of good quality bedding for night stay/Shift consisting of: -i) Mattress with warm cover size 6"x3" (6Kg)- 02 No’s ii) Quilt with warm cover size 5"x8" (6Kg)- 02 No’s iii) Pillows with covers - 02 No’s iv) Single bed warm blankets with one sided Fur- 02 No’s The filling material for mattress, quilt and pillow shall be of good quality cotton b) The job also includes providing of pressure cooker 5ltr 02 No’s, Steel patella(utensil) 5ltrs 02 No’s, cooking heater 01 No., room heater 01 No., steel buckets 10 litre capacity 01 No., Plastic bucket 10 litre capacity with Mug 02 No’s each, steel glasses 06 No’s, steel Plates with large spoons and bowls 03 No’s each, Cup and Saucer set (01 No. Set) and, 5kg Gas cylinder with burner/ stove. The job also includes providing of thermo-cool 15’x12’ along with excel matting of 15’x12’ size. The job also includes providing of unbreakable Plastic Chair table set consisting of chairs 04 No’s, extra heavy Table 01 No. The job also includes providing of good quality safety Door locks (03 No’s) of |
902 | Providing of solar/electrical lantern chargeable on both solar & electrical 220v supply. |
903 | Providing of bamboo ladders 18 feet long along with 15 feet long Link rods and HT Glove pair (01 No each) |
904 | Providing of 1 KW heat convector for operators for winter season |
905 | Providing and fitting of 01 No. LED (scroll type) sign board fabricated out of stainless steel and metal showing the names of water supply scheme and the Department. Size:6’×1’6” = 9 sft |
906 | Providing and fitting of 01 No. angle iron/sheet metal board duly painted showing various specifications of the mechanical and electrical equipment installed at site of appropriate sizes. |
907 | Providing, installation, Testing & commissioning of 415 ±10%V (output), 3 phase air cooled/water cooled Diesel Generator set as per IS 8528 (2018) and ISO 3046 (2002) for engine and IEC/IS 60034-1 for alternator suitably assembled and fitted in a pollution free acoustic enclosure / canopy of required size as per Ministry of Environment protection rule 1986 read with latest amendments. The DG Set is required to be fitted and tested on load at siteThe D.G Set shall have the following technical specification.Besides the above works the D.G set shall be provided with 12 V, 150 AH Lead acid battery of reputed make fitted inside the D.G set Canopy along with necessary accessories and battery charger of required capacity. Rest specification as per cluase "66"of SBD. Rating: 25 KVA DG SetAir cooled |
908 | (Part B) WSS Express Highway (Tanjloo & Manzmoh Stage 1st) (Adv. Cost Rs. 1,56,69,383/-) |
909 | Design, supply, providing, installation, successful testing and commissioning of vertical turbine pumping unit as per IS 1710 driven by VT motor for pumping water from Nallah of following parameters.• Site Condition Altitude = 1580 Meters (AMSL) Ambient Temperature = +40ºC to - 15ºC Relative Humidity = 60% • Type of water = Raw water having specific gravity of unity average. • Quality of water = Raw water with silt having medium to coarse sand. • Sump/liner Bed Level =8mbelow from Machine floor level • Water columnin liner/sump = 2 m abovefrom sump/liner bed level A. PUMP1. Discharge= 30000 GPH2. Type= Self water lubricated, VT pump, open line shaft.3. Liquid to be handled = Raw Water 4. RPM=1460 5. Head=135 M6. Efficiency= Not lessthan 60%7. Impeller= Semi-enclosed mixed flow all bronze/stainless steel8. Line shaft/head shaft = Stainless steel 9. Length of each line shaft = 1 mmaximum 10. Total length of line shaft = 10 m (excluding Head shaft)11. Impeller shaft= Stainless steel 12. Line shaft bearing = Cut less rubber/ Neoprene rubber 13. Line shaft coupling = Stainless steel 14. Suction Strainer = MS fabricated 15. Suction Bowl/Bell mouth=Cast Iron 16. Pump Bowl= Cast iron 17. Column pipe= Mild Steel of wall Manufactures Test Certificate to be apended and detailed specification as per cluase "6" ofof SBD Not less than 100 HP |
910 | Fabrication, providing, fitting, testing and commissioning of delivery Manifold(Y-Junction).Delivery Manifold shall have to be fabricated out of C-Class, G.I. pipe and shall be one size higher than as per the designed delivery size of the pumping unit (Discharge Head) for connecting the delivery of 02 no. pumping units with the rising main end including providing and fitting of matching flanges of delivery side of the pumping unit( Discharge Head). The job shall include Providing & Fitting of 02 No D.I. Non-Return Valves and 02 No D.I sluice valves. The size of the valves shall be inconformity with the designed delivery manifold/Y-junction of the pumping unit. The job further includes Providing & Fitting of matching flanges for fitting of valves as per IS-6392 and steel Nuts and bolts as per IS-1364-2002 and gaskets as per IS-638/79 with all necessary fittings i. e. Bends, Reducers, etc complete in all respect for complete job and strictly as per the requirement of the site conditions/department. Technical specifications of valves as under:- a) Non Return Valves:- §Diameter of the Valves : = 200mm diameter §Type of the Valve :=D.I. Non Return Valve (Flanged) §Body and cover = Ductile Iron §Disc= D.I. §Cover screws and Nuts = Stainless steel AISI 304 Pressure rating= 16 kg/cm² Gasket & seal = EPDM rubber (Gr.W 270) §No of Valves to be fitted : -= 02 no’s §Coating = inside and outside Epoxy powder coated,200 microns , shade RAL5005( Blue) §Material grade of valves shall be GGG-40 for above pressure rating. b) Sluice valves : §Diameter := 200mm diameter §Body ,Bonnet:= Ductile Iron §Wedge(Rubber Encapsulated)=Ductile Iron(Encapsulated with EPDM, Gr W270) §Spindle /stem := stainless steel, IS-6603,12Cr13/22Cr13,AISI410/420 §Stem Nut= Brass §Bonnet Gasket= EPDM rubber (Gr W 270) §Internal fasteners = Stainless steel 316/304 §Stem sealing= Toroidal NBR sealing rings (Min 03 ‘O rings) §Pressure rating= 16 kg/cm² §No. of valves = 02 Nos. §Coating =inside and outside Epoxy powder coated,200 microns , shade RAL5005( Blue) §Material grade of valves shall be GGG-40 for above pressure rating. c) Specification of Matching Flanges for pipe fittings: Providing and fitting of flanges required for fitting of above valves on delivery manifold shall be inconformity with the flanges of the above valves and shall conform as per IS-6392.The job also includes providing and fitting of steel nuts, bolts as per IS-1364-2002 and washers/Gaskets as per IS-638/79 for fitting of Valves. |
911 | OVER HEAD MONORAIL GANTRY: Manufacture, Supply, installation, Testing and Commissioning of on load 5 Ton capacity overhead monorail travelling crane inside pump house. The job comprises of Following specification. Specification i)Capacity………………………………..…….. = 5Ton ii)Length of runway girder…………..……….....=7500mm iii)Length of Bridge Girder…………..………….=7500mm iv)Height of offset from machine floor………... =5000mm Details of manufacture of crane:- The runway girders are fabricated out of ISMB-200.The length of each runway girder is 7500mm. The two runway girders shall be fitted/ rested on RCC shoulder beams of the pump house. The runway girders shall be aligned properly includes P/F of MS 300MM x300MM x12MM thick plates on both ends. The runway girders shall be Provided and Fitted with 32mm MS Square bar on top side for guiding of end carriages. Travelling Mono Rail Hoist:- The travelling monorail hoist shall be mounted on lower flange of I beam of size ISMB 200 as the main bridge girder. The both ends of the main bridge girder shall be fitted on end carriages fabricated out of 2 No MS channels of size ISMC-200 and 1200mm long on each side provided with travelling wheels along with suitable reduction gear mechanism, Line shaft with plumber blocks are to be operated by endless chain of 6 meter lift. Movement:- The wheels of the end carriage shall travel on 32mm M S sq bar which is welded to the runway girders. The travelling monorail Shall have to be provided with separate mechanical equipment for transversal and vertical travel of the load when operated from pump house floor through endless chain. The gantry as a whole shall be able to move conveniently with load from one place to another place and mechanism shall consist of gear train monorail of 5 Ton capacity having two wheels on either side on lower flange of the main bridge girder. The monorail should be P/F with chain pulley block of 5 ton capacity of spur gear type having 6 meter lift. Make of gear train monorail and chain pulley block:- The gear monorail and chain pulley block and all accessories should be as per Indian standards. The entire structure of gantry shall be painted with two coats of steel primer and two coats of enamel paint of yellow/ Greenshade. |
912 | RISING MAIN WITH FITTINGS:- Supply, laying, fitting, testing and commissioning of 200 MM diameter, 7 MM Thick,(heavy-class), G.I. flanged pipe line (as per technical details as under) to be used as common rising main from delivery Manifold of 02 No. VTtype pumping units up to the service reservoir ofStage 1st Details of job:- i. Providing and fitting of 200 MM diameter , 7 MM thick (heavy –class) G.I. pipes as per IS-3589, Gr-Fe 410.The job includes providing and fitting of steel flanges conforming to IS-6392 (Table 17) by way of DC Arc weldingThe job also includes providing and fitting of steel nuts, bolts and rubber gaskets as per IS-1363 part 1st 2002 and as per IS-638/79 respectively. ii.The job includes, dragging the pipes up to the site.The job includes loading, unloading and carriage of pipes up to site of work and laying along with the alignment as per the requirement of site condition/ department. The pipes shall be mostly joined together by flanged joints. iii.The pipe length as per requirement of site condition /department at the time of execution of job is to be laid underground in a trench made by manual/mechanical means in all kinds of soil not less than 1000mm (depth) x 800mm (width) in size including the back filling of the excavated soil after laying of the pipe. iv. The pipe line shall be tested and commissioned to the rated working pressure of 16 kg/cm² with ensuring of leak proof welded /flanged joints. v. All the tools, tackles and equipment such as carriers, portable Generator sets, welding Machines, crane, tripod stands, chain pulley Blocks, pulling –lifting machines etc and all other activities for completion of job are to be arranged by the contractor. vi.While laying the pipes along the fixed alignment , offsets and bends required for change of alignment shall be provided / fabricated from the supplied pipe and shall be fitted as per the site requirement. A)Technical specifications :- A.G. I. pipes (as per IS-3589, Gr-Fe-410)I.Nominal diameter = 200MM II. Wall thickness= 7MM III. Standard length = 4-6 Meter B. Steel flanges(as per IS-6392/1971(table 17)) I.Nominal size= 200MMII.Flange thickness= 24MM III.Raised face thickness=3MMIV.Bolting =M20V. No. of holes =12C.Welding Electrode DC Arc welding electrode D. Nuts and BoltsI. Steel Nuts and Bolts as per IS-1363-part 1st.E. Earth Work:- Earth work excavation for embedding of pipe line for all types of soil in bulk with a trench size as following. I.Trench width= 800MM II.Trench depth= 1000MMIII. Trenching by=Mechanical / Manual meansIV.Back filling = trenched out Material. |
913 | Providing and fitting ofProviding, Fitting, Testing and Commissioning of Non Return Valves as per following specifications Diameter of the Valves : =200 mm Type of the Valve :=D.I. Non Return Valve (Flanged) Body and cover = Ductile Iron Disc= D.I. Cover screws and Nuts = Stainless steel AISI 304 Pressure rating= 16 kg/cm² Gasket & seal = EPDM rubber (Gr.W 270) No of Valves:-=03 no’s Coating : Inside and outside Epoxy powder coated,200 microns , shade RAL5005( Blue) Material grade of valves shall be GGG-40 for above pressure rating. The valves as detailed above are to be installed after every 500 meters approximately of pipe length or as per the requirement of site condition /department for efficient utilization of the valves. The valves are to be joined with flanges welded to the pipes by double ended joints. Specification of Matching Flanges for pipe fittings: Providing and fitting of flanges required for fitting of above valves / pipe fittings on 200MM diameter rising main shall be inconformity with the flanges of the above valves/fittings and shall conform as per IS-6392.The job also includes providing and fitting of steel nuts, bolts as per IS-1364-2002 and washers/Gaskets as per IS-638/79 for fitting of Valves/ fittings. By-pass arrangement: Fabrication, supply, fitting and testing of suitable Bye-pass arrangement for Non-return Valves fitted in the rising main. The Bye-pass arrangement shall be made out of providing and fitting of 65MM diameter G.I. heavy duty pipe, suitable pressure rating gate valves, flanges, bends, steel nuts and bolts, washers etc required for complete job. |
914 | Providing, Fitting, Testing and Commissioning of Air Release Valve as per following specifications size& rating: NB 50 & PN16 Type : Automatic Air Valve Operation: Single chamber, directly operated by the flow medium, high Venting capacity up to sonic velocity MOC Body & Cover : Ductile iron inner Parts :Floater, shell etc. of stainless steel Coating: Inside and outside of epoxy coating. The ARV is to be installed at appropriate location on the rising main strictly as per directions of site Engineer. The location in the rising main pipe shall be cut to accurate size/holes suitable for installation of ARV. The job includes providing & welding of B class G I nipple in reduced section 65mm to 50mm to be welded with the pipe on one side & flanged on the other side. All flanges shall be conforming to IS6392, table 5.The gaskets for the flanges shall be confirming to IS 638-79 |
915 | Providing, fitting, testing and commissioning of Dismantling Joints suitable for 200 MM diameter rising main. The joint is to be provided to facilitate expansion / contraction and easy dismantling of the rising main. The joint shall be capable of absorbing 25MM elongation and 25MM contraction (total of 50MM) of rising main. The outer surface of the inner portion of joint (male part) and the inner surface of the outer portion (female part) which shall make contact with each other are to be machined in order to make sure that the contact is perfect and movement of these portions is easy. • Diameter of Dismantling joint = 200 MM • Material of Body =Steel S235JRG2 • Sealing: =EPDM/NBR • Threaded anchor bolts: =Steel S235JRG2, galvanized • Flanges = Steel S235 JR G2 • Pressure rating= 16 kg/cm² • No. of Dismantling joint = 02 Nos §Coating: Inside and outside Epoxy powder coated, 250 microns, shade RAL5005 (Blue) |
916 | Fabrication, Providing, fitting, , Testing and Commissioning of Wash out fabricated out of 150 mm dia.( Class – C )G.I pipe(18mts),150 mm Dia DI Sluice Valve,PN16 (01 No)and welded with 22 mm thickMS flange as per Table – 17 in two runs of welding . The job also includes cost on account of fabrication of 200x150 mm Dia reducer, earthwork excavation and suitable size nuts, bolts and rubber packing in the flanged joint. |
917 | VOLTAGE STABLIZER:- Providing, fitting, testing and commissioning of 200 KVA, 300Amperes, manually operated voltage stabilizer. The Voltage Stabilizer of 200 KVA (Copper Wound), shall be of following specifications: The voltage stabilizer shall be manually operated, oil cooled suitable to work on three phase, 50 Hz±3% Ac supply. The voltage stabilizer shall have transformer coils wound out of fiber glass tapped insulated electric grade copper strips with tapping at required intervals. The number of turns of coils and number of conductors in each turn with their size shall be of adequate design to withstand rated load of 585 amperes. Cotton / paper material shall be used for insulating of copper strip coils. The core cell of Voltage Stabilizer shall be assembled out of 52/92 grade silicon steel laminated sheets held together securely with the help of angle iron bracing and tightened with the help of galvanized nuts and bolts. The copper coils shall be inserted into three limbs of the cell and held firmly but duly insulated. The taping terminals shall be kept on all sides of the cells. The transformer cell shall be housed in a sheet metal tank made out of 4mm thick MS Sheets duly strengthening with stiffeners of MS flat /angle. The tank/ container shall be painted with two coats of steel primer both inside and outside and then with two coats of super enamel paint, synthetic gray from outside the container. The tank/container shall be provided with suitable cooling pipes to dissipate the heat generated from vent pipe at the top and drain pipe at the bottom with a plug. Hooks of proper size for lifting of stabilizer shall have to be provided on the top of the tank. The container of the voltage stabilizer shall be mounted on wheels for easy shifting /positioning. The stabilizer shall have suitable insulated lugs of appropriate size for cable connections. The indicating glass of the transformer oil level shall be provided on the transformer body. Voltage Range :Input 150Volts Output:415 ± 10% Volts Tape Changer: Manually operated balance type tape changer of 6Tapings. The stabilizer shall be provided with a free standing type control panel made out of sheet steel dust and vermin proof internally wired having following accessories. i. 02 No Volt Meters, 100 mm Sq Dial, 0 - 500 Volts, one each on incoming and outgoing circuits. The Voltmeters shall be flush mounted type with fuse and selector switch for three phases. The Voltmeter shall be of L&T make only. ii. A set of indicating lamps of three phase complete in all respects both on primary and secondary sides of stabilizer shall be provided and fitted. iii. Red and Green indicating lamps for ON / OFF display. The stabilizer shall be filled with required quantity of transformer oilup to the required level. All accessories and meters shall be of L&T make and conforming to relevant Indian standard codes. |
918 | Modular Control Panel (L T Panel):- A)Providing, fitting ,testing and commissioning of 400 Ampere LT Modular Control Panel with the following specifications: The LT Control Panel shall be totally enclosed, free standing type, sheet metal enclosed, dust & vermin proof, IP - 54 enclosures and shall be suitable for AC, 3 – phase, Voltage & Frequency as 380 ± 15% Volts and 50±3% Hz respectively and internally wired. The panel shall be applied with enamel paint of standard quality and of approved shade. The panel shall be extensible type and shall comprise of the one incomer, two outgoing motor control circuits, two no. auxiliary feeders, and one No. change over switch. The control panel shall be manufactured /supplied incompliance with latest relevant IEC/IEEE/IS Standards. The Control panel shall be fabricated out of 14 SWG cold rolled steel plates& properly supported using angles & channels. The Panels shall be divided into convenient continuous line. The whole panel shall be mounted on a base frame made out of suitable structural channels /beams. Joints of any kind in sheet shall be seam welded, all welding slag grounded off and welding pit wiped smooth with plumber metal. Compartment doors shall be inter-locked with the switch unit in such a way that the door shall not open when the feeder switch is ON. The panel shall be fitted with the same family of switches for various ratings with a view to ensure uniformity of design, maintenance and replacements. A horizontal wire way with screwed cover shall be provided at the top/bottom to take inter-connecting control wiring connection between different vertical sections. Separate and adequate compartments shall be provided for accommodating instruments, indicating lamps, control contactors and control fuses etc. These shall be accessible for testing and maintenance without any danger of accidental contact with live parts of the circuit breaker /busbar connections. B) BUSBAR CHAMBER :- The busbar chamber shall be provided at the top of the panel horizontally throughout the length. There shall be 3 Nos. of phase bus bar and 1 No neutral bus bar and 1 No earthing bus bar. |
919 | Modular cubical Soft starter panel:- The modular cubical type soft starter panel shall be fitted with 01 No. soft starters EMX4 with all necessary fittings suitable for safe operation of 100-150 HP motor . Details of Job:- Providing, fitting, testing and commissioning of 01 No. soft starters of 6-wire (inside Delta connection) suitable for 150 HP motor load. The soft starters shall be housed in a single panel of industrial type (Non –hazardous) totally enclosed, free standing cubicle type, dust and vermin proof, with IP54 sheet metal enclosure construction, and shall be internally wired and fitted with suitable rating copper bus-bars. The sheet metal enclosure of the soft starter shall be painted in enamel paint of standard quality of approved shade. The specifications of starter supplied shall be incompliance with latest relevant IEC/IEEE/IS Standards. The technical specifications /details of the soft starter shall be as under. i.Rated motor load=100- 150 HP ii.Rated voltage= 380 to 480 volts (±10-15)% iii.Rated frequency = 50 Hz ±3% iv. Ambient Temperature = - 10 °C to + 45 °C v.Enclosure type = IP54 The Soft starter panel shall be provided with the indicating, metering and control devices. I.Digital Voltmeter and ampere meter II. Phase current indication with suitable ammeter and selector switch.III.Audio – visual alarms /fault indicators.IV.Alarms acknowledge /reset / test push buttons.V.Low watt consumption LED type indicating lamps.The ‘protection system ‘of soft starter shall be designed for protection /safety of motors against the following: i.Sudden Short circuit.II.Electrical Over load. III. Complete external fault.IV. Starting under locked or jammed conditions of rotor. V. Dry run of motor.VI. System under voltage.VII. System over voltage. VIII. Over current protection IX. Phase reversal. X.Thermal overload.XI. Phase loss to protect motor from single phasing. The soft starters shall be provided with all necessary controls / safety protections as required as per IS /IEC standards. |
920 | Main Service Line Providing and fitting of 300 Sq.MM, XPLE, PVC sheathed Armored Aluminum cable 3 1/2 core from Sub-stationto the main L.T control Panel in the Pump House as per requirement including all thimbling crimping taping etc.(100Meters). The Cable shall conform to IS: 7098 part- I &II with latest amendments. The job includes laying and fitting of cable in air /underground as per the site conditions. The job includes crimping of the terminal ends of the cable with hydraulic crimping tool and providing and fitting of 300 amp capacity copper power conductor socketsand shall be as per relevant IS specifications/standards. |
921 | Internal Cabling Providing and fitting of 120 Sq.MM copper conductors, single core, PVC insulated, sheathed, 440 volts grade for inter-confectioning of the equipments like LT panel, voltage stabilizer, starter, motor etc. The job includes laying and fitting of suitable cable tray system in the station for laying/fitting of cable in air or as required as per the site condition with proper clamping etc. The job includes crimping of the terminal ends of the conductor with hydraulic crimping tool and providing and fitting of copper conductor sockets/thimbles of suitable size/ rating. The conductor shall be as per relevant IS specifications/standards. |
922 | Illuminations for water supply scheme premises:- Providing and fitting of 02 no. 9mtr long octagonal Hot Dip Galvanized steel Pole for installation of Luminaries with top diameter of 90 mm and bottom diameter of 200 mm. The bottom of the pole shall have to be provided and welded with a steel plate of 16 mm thick and 260 mm x 260 mm size and provided with 04 No’s of holes drilled for grouting bolts. The pole shall be fitted with MS ring fixture for fixing of Luminaries. The wiring for luminaries shall have to taken from inside for which required holes shall have to drilled. The Pole along with all the fixtures shall be coated with red oxide primer followed by two coats of Al paint. Luminaries:- 1) Flood Lights Providing and fitting of Four no. flood Lights on each pole to be installed in four directions on the above Octagonal poles and shall be of 120 watt LED type complete in all respect. The job shall include providing & fitting of 16 Amp ON-OFF/MCB Switches on junction box for each floodlight fitted at the bottom of pole 6 feet from the ground level with locking arrangement. 2)Cabling for Luminaries The cabling for luminaries shall be 4.0 mm Sq Cu wire (90mtrs) of standard quality (Havells/L&T/ABB) make in black and red as per ISI specifications. 3) Service Line for Luminaries The cabling shall be of 2 Core, 16 mm Sq, PVC Insulated Al Cable (90 mtrs) . The Cabling shall have to be laid underground through a PVC conduit of suitable size and the job includes cost on account of earth excavation and back filling of the excavated soil after laying of the cable. |
923 | Auto Voltage Stabilizer (5 KVA) The Auto Voltage Stabilizer shall be of Copper wound, 5 KVA Rating designed for an input Voltage of 90- Volt and Output Voltage of 230 Volt with Power Coated Enclosure |
924 | 1. Power Inverter Providing and fitting of Power Inverter of 1400 VA Rating including providing of 200 AH Lead acid Battery of suitable rating complete in all respects. 2. Operator Room Lighting. i) providing and fitting and testing of (10 no’s) lighting to the Operator Room with lighting points in 2.5 sq mm PVC insulated copper wire including P/F of 5 Amp ON-OFF switches on Bakelite Sheet, 16 watt power saver and all other allied fixtures as required. The wiring shall be concealed. ii)Providing and fitting 0f (05 no’s)Heating Points to the operators roomin 4 sq mm PVC insulated copper wire including P/F of 16 Amp SS Combine on Bakelite Sheet. The wiring shall be concealed. 3. Pump House Luminaries Providing and fitting and testing of flood lights for Pump House with energy saving flood lights luminaries and high power cob LED light source and symmetric optics Jeta 30 Watt LED (04 Nos), 5000 KThe job includes all the required wiring and other required accessories complete in all respect. 4. Electric Fans Providing and fitting of 02 No. Electric Fans of ceiling mounted typecomplete with regulator / controlling switch, wiring in 2.5 sq.mm PVC insulated copper wire. |
925 | TOOL KIT For Maintenance: - The Tool Kit for maintenance as per detailed specification in cluase 56 of SBD |
926 | Providing of following items for operational staff for smooth functioning of the scheme: Bamboo link disconnecting/connecting rod with MS hook-02 No 20 feet longaluminum/steel ladder-01 No Snow shoes 06pairs. Matting comprising of 12 mm thermo cool, jute matting/ excel, floor blankets –300 sft each Bedding comprising ofmattress, razai,excel blanket, pillow – 04sets Cooking and bathroom items as 4 ltr pressure cooker, 2.8 ltr rice cooker, pan, aluminum cooking vessels – 02 No, steel plates – 04 No, Steel glass ( tumblers) – 04 No, cooking spoons – 02 No, Cups – 04 no, Plastic Jug, Electric heater, 20 ltr plastic buckets – 02 No, 1 ltr plastic mugs – 02 No, Chargeable lantern Ands lite make – 01 No, Two Burner Gas stove with domestic gas cylinder – 14 kg capacity complete with gas pipe and regulator.—01No Heat convector / Heating Blower – 02 No Plastic chairs of Samrudhi make (04 nos) and plastic table 01 No Uniform / track suit for operational staff-06 Nos. Fabrication., providing of angle Iron bed from 50x50x6mm angle Iron of size 8’x6’. The 8’x6’ rectangular frame is to be supported on 06 number legs of size 2". and two number diagonal crosses for proper supporting of 19mm plywood .The job includes paintingof red oxide paint of the bed |
927 | Providing, laying & fixing with adhesive/bonding material of insulation rubber mats on the floor of the pump house, covering area around electro-mechanical machinery for safeguarding the life & limb of the workmen due to possible leakage of current & short circuit. The floor surface shall be made good & shall be free from dust, grease, foreign material & moisture free. The mats shall be as per IS 15652:2006 & shall have the following specifications: - Composition:Rubber (synthetic mats for electrical purpose) Thickness:- 2.50mm Size : - 1M wide. The rubber mats shall be accepted with manufacturers test certificate. |
928 | Providing/Fitting of80 MM Dia flexible convas sleeve/conduit for carrying cables of different sizes. |
929 | Fabrication providing & fitting of split type MS Clamps 8mm thick,6” wide and 2.5 feet long for lowering of column pipes. The job includes Providing & tightening of 03 No appropriate size nuts and bolts no either side along with5 mtr ¾” dia sling rope. |
930 | Providing / fitting / testing of ABC MAP (Mon ammonium Phosphate) fire extinguisher with fallowing specifications Chrome plated brass valve Chrome plated brass discharge nozzle Skirted steel cylinder Rechargeable Inter changeable components Heavy duty steel carrying handle Stainless steel house trap Steel forked wall bracket Capacity 6 Kgs Included is fabrication of angle iron base frame wall mount type with brackets as per site requirement. |
931 | Providing of set of 06 No 9.5-liter capacity GI buckets painted in post office red color with prior coat of red oxide primer & written with white paint “FIRE” & mounted on angle iron frame with brackets of appropriate size & capacity including cost of providing / filling of sand etc. Included is providing First Aid box as approved by Indian red cross conforming to IS 2217 & amended till date |
932 | Providing, fitting, testing and commissioning of APFC Panel (100 KVAr) (FULLY AUTOMATIC POWER FACTOR CONTROLLER)with the following specifications: The Panel shall be totally enclosed, free standing type, sheet metal enclosed, dust & vermin proof, IP - 54 enclosures and shall be suitable for AC, 3 – phase, Voltage & Frequency as 415 ± 15% Volts and 50±3% Hz respectively and internally wired. The panel shall be applied with enamel paint of standard quality and of approved shade. The panel shall be extensible type and comprises of the material with specifications as specified in Annexure A . The Control panel shall be fabricated out of 14 SWG cold rolled steel plates & properly supported using angles & channels. The Panels shall be divided into convenient continuous line. The whole panel shall be mounted on a base frame made out of suitable structural channels /beams. Joints of any kind in sheet shall be seam welded, all welding slag grounded off and welding pit wiped smooth with plumber metal. Compartment doors shall be inter-locked with the switch unit in such a way that the door shall not open when the feeder switch shall be ON. The panel shall be fitted with the same family of switches for various ratings with a view to ensure uniformity of design, maintenance and replacements. A horizontal wire way with screwed cover shall be provided at the top/bottom to take inter-connecting control wiring connection between different vertical sections. Separate and adequate compartments shall be provided for accommodating instruments, indicating lamps, control contactors and control fuses etc. Annexure – A APFC Panel ( 100 kVAr ) DESCRIPTION Incomer RatingQty TP MCCB, 35KA, TM O/l & S/C Trip release 160 A 1 Control MCB, 10KA, C Curve6 A 1 Indication Lights, 230V ACR/Y/B3 Digital APFC Relay,1 Phase, MP Based, 230V Aux. Supply 8 stage 1 A/M Selector Switch for Auto & Manual 6A 1 Capacitor Bank20 KVAR4 set TP MCCB, 10 KA, TM O/L & S/C release 63 A4 Capacitor Duty Power Contactor, 220V AC Coil 20 kVAr4 Power Capacitor, Cyl. Capacitor- HD Plus, 440V AC 20 kVAr4 Illuminated Switch For Manual Switching & Step IndicationR 4 Capacitor Bank 10 KVA 1 set TP MCCB, 10 KA, TM O/L & S/C release 25 A 1 set Capacitor Duty Power Contactor, 220V AC Coil10 kVAr 1 Power Capacitor, Cyl. Capacitor- HD Plus, 440V AC10 kVAr 1 Illuminated Switch For Manual Switching & Step IndicationR1 Capacitor Bank 5KVAR1 set TP MCCB, 10 KA, TM O/L & S/C release20 A 1 Capacitor Duty Power Contactor, 220V AC Coil5 kVAr 1 Power Capacitor, Cyl. Capacitor- HD Plus, 440V AC 5 kVAr 1 Illuminated Switch For Manual Switching & Step Indication R1 Capacitor Bank 3KVAR1 set TP MCCB, 10 KA, C curve10 A1 TP Power contactor 09 A1 Power Capacitor, Cyl. Capacitor- HD Plus, 440V AC 03 kVAr1 Illuminated Switch For Manual Switching & Step IndicationR1 Capacitor Bank2kVAR1 set TP MCCB, 10 KA, TM O/L & S/C release 9 A 1 TP Power contactor 06A 1 Power Capacitor, Cyl. Capacitor- HD Plus, 440V AC02 kVAr1 Illuminated Switch For Manual Switching & Step Indication R 1 ENCLOSURE with CRCA Sheet Steel & Cu Bus Bar |
933 | P/F/Testing of one No MCCB, Manually operated, 400 Amp , 50 Ka Breaking capacity with overload and short circuit protection of L and T/ Havel’smake. The switch shall be enclosed in dust proof sheet enclosure shall be suitable for 3 phase AC supply , 50 HZ frequency and fitted near existing sub-station. The equipment comprises of the material 400 Amp MCCB-4pole Breaking Cap—50 KA Voltmeter -0-500 V with selector switch 400 Amp Copper bursars Neon indicating lamps suitable for 220 V AC Duty –Outdoor |
934 | Providing, Installation, Fitting, Testing and Commissioning of 250KVA D.G Setas per following: TECHNICAL SPECIFICATIONS:- Supply of 250KVA 3- Phase DG Set suitable for standard NTP and 60 % relative humidity. The DG Set shall be comprising of diesel engine and alternator coupled together with heavy duty flexible coupling and mounted on MS base frame along with standard accessories, control panel, battery, anti – vibration pads and M.S. canopy duly painted conforming to noise pollution specifications /requirements of environmental protection rules 1986 as laid down by Ministry of Environmental protection and forest, read with GSR- 371 (E) date 17-02-2002 & GSR 520 (E) date 01-07-2003 in respect of emission norms for the Engine and in respect of noise level for the D.G Sets for supplies read with up to date amendments and as applicable at time of supply. The engine shall conform to IS / 10000/ BS -649 / BSS 5514. The DG set should be rated for continuous duty with overload provision of 10% for the period not exceeding one hour in 12 hours. The specifications are as under:- Alternator : The alternator shall be self – regulated for 250KVA rating and conforming to IS 13364 (II) and shall be brushless. The alternator shall be scratch protected, drip proof with IP-23 degree of protection as per IS 4691/85 and shall be two bearing type B-3 construction, foot mounted ensuring rigidity epoxy gel coated, positive voltage built up compact design with high performance AVR suitable for continuous and trouble free operation. Output rating at = 250KVAstandard operating conditions Rated Speed = 1500 RPMType = 3 phase Brush lessEfficiency =88 % or aboveVoltage= 415 V ± 3% at 50 Hz.Power factor= 0.80Alternator winding = Copper (PVC insulated-H class) Diesel Engine (prime mover): The engine is diesel driven to develop requisite BHP at 1500 RPM for the alternator rated as above at an altitude of 1764 (AMSL) with ambient temperature ranging from (-) 10° to (+) 40 °C under 60% humidity Conditions: Type = Turbo charged Gen set rating = 250 KVA standard operating conditionsSpeed = 1500 RPM Control = ECM-controlledMethod of start = Battery operated Cooling System = Air cooled( Preferably) Accessories : Besides all accessories/ standard equipment to make the Engine complete in all respects and ready for use with following equipments Anti Vibration Mountings Cold starting unit Safety control against low lube oil pressure and high cooling water temperature along with tripping FUEL TANK: Suitable capacity floor mounted type made of MS sheet and duty painted. The fuel tank shall fitted with return connections, air vent, drain valve, level indicator and fuel pipes, safety control for high canopy temp. BATTERY: Suitable battery with Rack and cables along with lead terminals connected with charging dynamo and cut out fitted with 24 volts-starting system. Engine instrument panel It shall be fitted with starting switch, with fays, lube oil, gauge, temp & pressure gauge, speedometer and hour meter etc. Standard Control Panel : It shall be fabricated out of powder coated sheet metal preheated and aesthetically finished. The control panel shall be totally enclosed, dust, vermin proof, floor mounted with IP-53 degree of protection as per AS 2147: 62. The panel control shall consist of following instruments:- (0-600) V-A.C Voltmeter(s) of class 1.5 accuracy with four position selector switch for 3 – phase D.G. Set A.C – Ammeter of class 1.5 accuracy of suitable rating for 250KVA DG set. HRC fuse of suitable rating for 250KVA DG set.MCCB / MCB‘s of suitable rating for 250KVA DG set.Frequency meter digital type of suitable rating for 250KVA DG set. Energy meter of suitable rating for 250KVA DG set. Power factor meter digital type of suitable rating for 250KVA DG set.Push button switch for ON & OFF operation.Pilot lamps (3 No’s) of suitable rating for 250KVA DG set. Instrument and control fuses Battery charger connected to voltage regulator voltmeter and ammeter for charging battery from the mains. This shall be in addition to the battery charging alternator fitted on the engine instrument and control fuses. All the above components shall be properly mounted duly wired and labeled. Suitable terminals are Provided for panel incoming and outgoing connections. Canopy: M.S canopy of suitable thickness to with stand snow load, compact and aesthetically superior duly painted and able to control noise pollution as per requirements of environmental (protection) rules Technical literature / catalogue shall be provided. The following jobs are also included in the scope of work: a) Providing and fitting of Battery charger / inverter connected to voltage regulator voltmeter and ammeter for charging battery from the mains. This shall be in addition to the battery charging alternator fitted on the engine instrument and control fuses. b) Providing and fitting of 300 Sq.MM, XPLE, PVC sheathed ArmoredAluminum cable single core from DG set panel to the main L.T control Panel in the Pump House as per requirement including all thimbling crimping taping etc.(50Meters) c) P/F ofDowels/reputed make Aluminium thimbles duly crimped with a hydraulic crimping tool and properly insulated with tape to avoid air flow inside the insulation.(12jobs) d) Requisite size Concrete block for resting of DG set e) Standard tool set for DG set maintenance The job also includes first filling of HSD 210 ltrsand testing on full load at site. |
935 | Details of Angle Iron Canopy for 250 KVA and 25 KVA DG Sets housed under one Roof:- CONCRETE BED BLOCK WITH RAMP :- Earth work in excavation by manual means in trenches for foundation, drains, pipes, cables (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and reaming of bottom lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed.(All kinds of soil 01 meter from cutting edge) |
936 | Providing and laying hand packed stone soling |
937 | Centering and shuttering including strutting , propping etc. and removal of form work for Foundation , footings , bases for columns |
938 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering . all work upto plinth level with 1 : 2 : 4 mix (1 cement , 2 coarse sand , 4 graded stone aggregate 20mm nominal size) |
939 | P/Laying/Applying of 15 mm thick plaster in 1:4 (cement : sand ) mix over the whole expose surface |
940 | P/Fabrication/Errection and hoisting of:- A) Verticle Posts: 125 mm dia 5 mm thick 10 feet long MS pipe - 12 No 300 x 300 mm x 10 mm thick MS base plate- 12 No 300 x 300 mm x 10 mm thick MS matching plates to be grouted in cement concrete block with 15 mm dia bolts projecting out of concrete and welded to the grouted plate on the other side cw suitable size nuts and washers – 12No 150 x 150 mm x 6 mm thick MSplates to be welded on top of posts and their matching plates to be welded on the beams, - 24 No = 744.8 kgs B)ISA (50x50x6) mm Double section for the fixing vertical Posts at the top and for the tie beams:- Angle for Fixing vertical Posts=2x2(9m+4m)=52 R.m @4.5 kg / rmt=234 Kgs Tie Beams =¯¯5x2 x5m= 50 m @4.5 kg / rmt=225 Kgs Truss: ISA (50x50x6) mm double section for truss beam,King Post,Strutts and rafter etc [5x2 ( 2.5m +2.925m +1.833m+1m+0.694m+0.50m)2 +5x2x1.52m=204.16 R.m @4.5 kg / rmt =918.72 Kgs Gusset plates in MS 70 No.150 x 200 x 6mm=0.0126 cum@ 7856Kg/cum= 98.98 Kg. C)Perlins (40*40*5) = 12¯× 10m= 120mtrs @ 3.00 kg/m = 360 Kgs Total Iron:(744.8+234+225+918.72+98.98 +360)Kgs= 2581.5 kg D)Painting of whole shed with one coat of red oxide and two coats of enamel paint after through surface cleaning by using proper grade of emery paper.The job includes cutting, welding, hoisting etc as per site requirement. |
941 | Providing and fitting of CGI Green color coated sheeting for roofing of shed in 26 SWG(0.50mm) gauge along with P/F of j-hookswith nuts/washers and plane sheeting for Ridge .=2¯x10mx3m+10mx0.6m = 66 S.m |
942 | Supply , installation , commissioning and creation of pole mounted, outdoor type Electric Sub Station as per the technical specifications given here under - Specifications conforming to IS: 1180 (Part 1) 2014 with latest amendments. Type: HT/LT Transformer Type of cooling: ONAN. Operating conditions: Input =11000 volts Output =433 volts AC supply in 3- phase. Terminals: Input=3 No. HT bush rods with insulators, washer, nuts etc. Output=4 No. LT bush rods switch insulators, washers, nuts etc. Core: The core shall be of high permeability to reduce core losses and the strips shall be of suitable size and gauge. Transformer Coils: Suitable number of HT and LT coils in each leg of the core. The transformer coils shall be fabricated out of superior quality aluminum wire/strips, properly wound. The HT transformer is completely filled with suitable grade transformer oil up to required level. The job includes carriage, and all leads and lifts involved. The HT transformer shall be of reputed make from an ISO certified company as per relevant standards and a test certificate shall be provided before installation. The transformer shall also be provided with breather fill with silica jel crystals, conservator with oil level indicator, explosion vet and adequate radiator fins/ Tubes. The impedance of transformer shall be as per IS: 1180 (Part 1) 2014 with latest amendments. NOTE: The scope of the work shall include obtaining of necessary inspection/clearance certificate from the concerned department for all the required equipment. The testing and commissioning shall be completed only after obtaining above certificate. |
943 | HT Cable for Tapping Providing and fitting of 95 Sq.MM, 3 -core, XLPE HT (ABC) Aerial Bunched cableThe cable shall be fitted from nearby HT line up to the electric sub-station. The Cable shall conform to IS-14255 and IS: 7098 part- II with latest amendments The job includes crimping of terminal ends of the cable by hydraulic crimping tool and providing and fitting of suitable cable kits as required and shall be as per relevant IS specifications/standards. |
944 | (Part C) WSS Express Highway (Tanjloo & Manzmoh Stage 2nd) (Adv. Cost Rs. 2,10,46,197/-) |
945 | Design, Manufacturing, Installation, Testing and commissioning of Hollow shaft Vertical Turbine Pumping unit as per following specifications" A.PUMP: 1.Discharge =30000 GPH 2. Type =Self water lubricated, Vertical Turbine pump, Open line shaft type with delivery above floor level.3. Liquid to be handled =Raw water having solids in suspension.4. RPM =1450 5. Head=178 Meters 6. Efficiency= 75% without negative tolerance 7. Material of impeller= Semi enclosed open shrouded impellers mixed flow (Bronze grade V of BIS 318)8. Material of line shaft and shaft coupling=Stain less steel AISI 410 9. Material of Impeller shaft= Stain less steel AISI 41010. Intermediate shaft=Stain less steel 11. Column pipe= Mild Steel 150 mm nominal dia12. Suction strainer=MS Fabricated13. Bell mouth= CI 14. Pump Bowl=CI(Pump bowls should be fastening through screws)15.LevelsSump bed level=100 meters (Proposed) Machine floor level=106MetersMinimum water level=3 Meter B.MOTOR: 1.Type =Hollow shaft AC Squirrel cage induction motor 2.Rating=Not less than 150 HP 3. Frequency=50 HZ+3%4. Working voltage=380+15V,03 phase 5.RPM=1450 Sync 6.Efficiency=Not less than 80%7.Class of insulation=F 8. Enclosure=TEFC 9. IS standard=IS 325-1970 10. Quantity=01 No. 12. Bearings=Thrust bearing shall be suitable and of adequate capacity to carry the weight of all rotating parts and the hydraulic down thrust 13. Ratchet=Non-reversing ratchet or similar mechanism should be provided to the motor to prevent reverse rotation. 14.Continuous maximum rating= Continuous maximum rating of the motor shall be at least 20% above the maximum power absorbed by the pump under any operating point within stipulated head range of the pump or at least 10% above the power required at shut off, whichever is higher 15. Discharge Head Assembly=Discharge head assembly shall be fabricated from MS. It shall be incorporated in full diameter elbow mounting flange for motor with suitable tapping for pressure gauge. The discharge head assembly shall be of robust construction and shall be designed to support to entire static and dynamic load of pump assembly, water column and motor. The discharge head assembly shall have an arrow indicating direction of rotation of pump. The discharge head may have a stuffing box with renewable bushing. The location shall be easily accessible. The lantern ring and gland follower shall be split type. The job includes fabrication/Fitting of necessary base frame/ platform out of required ISMB, MS channels, chequered sheets etc. as per site requirement. |
946 | Fabrication, providing, fitting, testing and commissioning of delivery Manifold(Y-Junction).Delivery Manifold shall have to be fabricated out of C-Class, G.I. pipe and shall be one size higher than as per the designed delivery size of the pumping unit( Discharge Head) for connecting the delivery of 02 no. pumping units with the rising main end including providing and fitting of matching flanges of delivery side of the pumping unit( Discharge Head). The job shall include Providing & Fitting of 02 No D.I. Non-Return Valves and 02 No D.I sluice valves. The size of the valves shall be inconformity with the designed delivery manifold/Y-junction of the pumping unit. The job further includes Providing & Fitting of matching flanges for fitting of valves as per IS-6392 and steel Nuts and bolts as per IS-1364-2002 and gaskets as per IS-638/79 with all necessary fittings i. e. Bends, Reducers, etc complete in all respect for complete job and strictly as per the requirement of the site conditions/department. Technical specifications of valves as under:- a) Non Return Valves:- §Diameter of the Valves : = 200mm diameter §Type of the Valve : =D.I. Non Return Valve (Flanged) §Body and cover = Ductile Iron§Disc = D.I.§Cover screws and Nuts = Stainless steel AISI 304Pressure rating= 16 kg/cm² Gasket & seal = EPDM rubber (Gr.W 270)§No of Valves to be fitted : -= 02 no’s§Coating = inside and outside Epoxy powder coated,200 microns , shade RAL5005 (Blue)§Material grade of valves shall be GGG-40 for above pressure rating. b) Sluice valves : §Diameter := 200mm diameter §Body ,Bonnet: = Ductile Iron §Wedge(Rubber Encapsulated)=Ductile Iron(Encapsulated with EPDM, Gr W270) §Spindle /stem := stainless steel, IS-6603,12Cr13/22Cr13,AISI410/420§Stem Nut= Brass§Bonnet Gasket = EPDM rubber (Gr W 270)§Internal fasteners= Stainless steel 316/304 §Stem sealing = Toroidal NBR sealing rings (Min 03 ‘O rings) §Pressure rating= 16 kg/cm²§No. of valves = 02 Nos.§Coating=inside and outside Epoxy powder coated,200 microns , shade RAL5005( Blue)§Material grade of valves shall be GGG-40 for above pressure rating. c) Specification of Matching Flanges for pipe fittings: Providing and fitting of flanges required for fitting of above valves on delivery manifold shall be inconformity with the flanges of the above valves and shall conform as per IS-6392.The job also includes providing and fitting of steel nuts, bolts as per IS-1364-2002 and washers/Gaskets as per IS-638/79 for fitting of Valves. |
947 | OVER HEAD MONORAIL GANTRY: Manufacture, Supply, installation, Testing and Commissioning of on load 5 Ton capacity overhead monorail travelling crane inside pump house. The job comprises of Following specification. Specification i)Capacity………………………………..…….. = 5Ton ii)Length of runway girder…………..……….....=7500mm iii)Length of Bridge Girder…………..………….=7500mm iv)Height of offset from machine floor………... =5000mm Details of manufacture of crane:- The runway girders are fabricated out of ISMB-200.The length of each runway girder is 7500mm. The two runway girders shall be fitted/ rested on RCC shoulder beams of the pump house. The runway girders shall be aligned properly includes P/F of MS 300MM x300MM x12MM thick plates on both ends. The runway girders shall be Provided and Fitted with 32mm MS Square bar on top side for guiding of end carriages. Travelling Mono Rail Hoist:- The travelling monorail hoist shall be mounted on lower flange of I beam of size ISMB 200 as the main bridge girder. The both ends of the main bridge girder shall be fitted on end carriages fabricated out of 2 No MS channels of size ISMC-200 and 1200mm long on each side provided with travelling wheels along with suitable reduction gear mechanism, Line shaft with plumber blocks are to be operated by endless chain of 6 meter lift. Movement:- The wheels of the end carriage shall travel on 32mm M S sq bar which is welded to the runway girders. The travelling monorail Shall have to be provided with separate mechanical equipment for transversal and vertical travel of the load when operated from pump house floor through endless chain. The gantry as a whole shall be able to move conveniently with load from one place to another place and mechanism shall consist of gear train monorail of 5 Ton capacity having two wheels on either side on lower flange of the main bridge girder. The monorail should be P/F with chain pulley block of 5 ton capacity of spur gear type having 6 meter lift. Make of gear train monorail and chain pulley block:- The gear monorail and chain pulley block and all accessories should be as per Indian standards. The entire structure of gantry shall be painted with two coats of steel primer and two coats of enamel paint of yellow/ Greenshade. |
948 | RISING MAIN WITH FITTINGS:- Providing/supplying and fitting of G.I flanged Rising Main at site. The Pipe shall be hot dip Galvanized, class B and C confirming to IS 1239. The job includes providing and fitting of M.S Flanges conforming to BIS 6392/1997 Table 17 (Rating PN16). The flanges shall be double welded both from inside and outside of the pipe using standard electrode of reputed make. Flanges (as per IS 6392/1997 Table:17) Thickness shall conform to IS 6392 Part 1st Table-17. Detailed specification as per cluase "8" of of SBD DN 200 C(Heavy) pipe, 6mm Thick |
949 | Providing and fitting of Ductile Iron double flanged, Slanted seat swing check valve( NRV) as per IS 5312. The body shall be of ductile cast iron with fully encapsulated vulcanized EPDM rubber(Approved for drinking water). Rest specification as per cluase "13" of SBD. 200 mm |
950 | Providing, fitting, testing and commissioning of ARV (Air Release valve) as per IS 14845 to be fitted to G.I rising Main. Size: 50mm PN: 1.6/16 Rest of Specification/Details areas per clause 14 of SBD |
951 | Providing, fitting, testing and commissioning of Dismantling Joints suitable for 200 MM diameter rising main. The joint is to be provided to facilitate expansion / contraction and easy dismantling of the rising main. The joint shall be capable of absorbing 25MM elongation and 25MM contraction (total of 50MM) of rising main. The outer surface of the inner portion of joint (male part) and the inner surface of the outer portion (female part) which shall make contact with each other are to be machined in order to make sure that the contact is perfect and movement of these portions is easy. • Diameter of Dismantling joint = 200 MM • Material of Body =Steel S235JRG2 • Sealing: =EPDM/NBR • Threaded anchor bolts: =Steel S235JRG2, galvanized • Flanges = Steel S235 JR G2 • Pressure rating= 16 kg/cm² • No. of Dismantling joint = 02 Nos §Coating: Inside and outside Epoxy powder coated, 250 microns, shade RAL5005 (Blue) |
952 | Fabrication, Providing, fitting, Testing and Commissioning of Wash out fabricated out of 150 mm dia.(Class – C)G.I pipe (22 mts),150 mm Dia DI Sluice Valve, PN16 (01 No) and welded with 22 mm thickMS flange as per Table – 17 in two runs of welding . The job also includes cost on account of fabrication of 200x150 mm Dia reducer, earthwork excavation and suitable size nuts, bolts and rubber packing in the flanged joint. |
953 | VOLTAGE STABLIZER:- Providing, fitting, testing and commissioning of 300 KVA, 425Amperes, manually operated voltage stabilizer. The Voltage Stabilizer of 300 KVA (Copper Wound), shall be of following specifications: The voltage stabilizer shall be manually operated, oil cooled suitable to work on three phase, 50 Hz±3% Ac supply. The voltage stabilizer shall have transformer coils wound out of fiber glass tapped insulated electric grade copper strips with tapping at required intervals. The number of turns of coils and number of conductors in each turn with their size shall be of adequate design to withstand rated load of 585 amperes. Cotton / paper material shall be used for insulating of copper strip coils. The core cell of Voltage Stabilizer shall be assembled out of 52/92 grade silicon steel laminated sheets held together securely with the help of angle iron bracing and tightened with the help of galvanized nuts and bolts. The copper coils shall be inserted into three limbs of the cell and held firmly but duly insulated. The taping terminals shall be kept on all sides of the cells. The transformer cell shall be housed in a sheet metal tank made out of 4mm thick MS Sheets duly strengthening with stiffeners of MS flat /angle. The tank/ container shall be painted with two coats of steel primer both inside and outside and then with two coats of super enamel paint, synthetic gray from outside the container. The tank/container shall be provided with suitable cooling pipes to dissipate the heat generated from vent pipe at the top and drain pipe at the bottom with a plug. Hooks of proper size for lifting of stabilizer shall have to be provided on the top of the tank. The container of the voltage stabilizer shall be mounted on wheels for easy shifting /positioning. The stabilizer shall have suitable insulated lugs of appropriate size for cable connections. The indicating glass of the transformer oil level shall be provided on the transformer body. Voltage Range :Input 150Volts Output:415 ± 10% Volts Tape Changer: Manually operated balance type tape changer of 6Tapings. The stabilizer shall be provided with a free standing type control panel made out of sheet steel dust and vermin proof internally wired having following accessories. i. 02 No Volt Meters, 100 mm Sq Dial, 0 - 500 Volts, one each on incoming and outgoing circuits. The Voltmeters shall be flush mounted type with fuse and selector switch for three phases. The Voltmeter shall be of L&T make only. ii. A set of indicating lamps of three phase complete in all respects both on primary and secondary sides of stabilizer shall be provided and fitted. iii. Red and Green indicating lamps for ON / OFF display. The stabilizer shall be filled with required quantity of transformer oilup to the required level. All accessories and meters shall be of L&T make and conforming to relevant Indian standard codes. |
954 | Modular Control Panel (L T Panel):- A) Providing, fitting ,testing and commissioning of 630 Ampere LT Modular Control Panel with the following specifications: The LT Control Panel shall be totally enclosed, free standing type, sheet metal enclosed, dust & vermin proof, IP - 54 enclosures and shall be suitable for AC, 3 – phase, Voltage & Frequency as 380 ± 15% Volts and 50±3% Hz respectively and internally wired. The panel shall be applied with enamel paint of standard quality and of approved shade. The panel shall be extensible type and shall comprise of the one incomer, two outgoing motor control circuits, two no. auxiliary feeders, and one No. change over switch. The control panel shall be manufactured /supplied incompliance with latest relevant IEC/IEEE/IS Standards. The Control panel shall be fabricated out of 14 SWG cold rolled steel plates& properly supported using angles & channels. The Panels shall be divided into convenient continuous line. The whole panel shall be mounted on a base frame made out of suitable structural channels /beams. Joints of any kind in sheet shall be seam welded, all welding slag grounded off and welding pit wiped smooth with plumber metal. Compartment doors shall be inter-locked with the switch unit in such a way that the door shall not open when the feeder switch is ON. The panel shall be fitted with the same family of switches for various ratings with a view to ensure uniformity of design, maintenance and replacements. A horizontal wire way with screwed cover shall be provided at the top/bottom to take inter-connecting control wiring connection between different vertical sections. Separate and adequate compartments shall be provided for accommodating instruments, indicating lamps, control contactors and control fuses etc. These shall be accessible for testing and maintenance without any danger of accidental contact with live parts of the circuit breaker /busbar connections. B) BUSBAR CHAMBER :- The busbar chamber shall be provided at the top of the panel horizontally throughout the length. There shall be 3 Nos. of phase bus bar and 1 No neutral bus bar and 1 No earthing bus bar. The bus bars shall be air insulated and made-up of high conductivity copper with current density of suitable rating for 630 Ampere. All panel compartments shall be provided with suitable cable alley and vertical bus bar alley. Suitable segregation shall be provided in between busbar chamber and adjoining compartments. The busbar shall be PVC sleeved with color strips of red, yellow, blue and black and the same shall be arranged in accordance with IS-375.The busbar shall be properly segregated, suitably braced with insulated supports placed at appropriate intervals to withstand the electromagnetic stresses during short circuit. Electrical clearances shall be maintained between phase, neutral and body as per standards. C)Change over switch (01 No) : One No 630 Ampere rating, as per IEC-60947-3 & IS-13947-3415 ±5% volts, 50±3% Hz, on load change over switch, of L&T make. D)Incoming feeder:- a.One No. Air circuit breaker draw out type ,manually operated ,mechanically interlocked ,04 pole, 630 Ampere ratingas per IEC-60947-2 & IS-13947-2, having asuitable breaking capacity of 50 KVA provided with overload and short circuit protection devices. b. Indicating Lamps shall be cluster LED type suitable to operate on 220 V AC. c.One No. 144 mm square dial ,flush pattern ,industrial grade , CT operated , ammeter of 0-800 Ampere capacity. d. Three No. current transformers of required capacity and ratio e.One No. 3 –way and “OFF: ammeter selector switch f. One No.144 mm square dial, flush pattern. Industrial grade, voltmeter of 0-500 Volts capacity . g. One No. 3-way and ‘OFF” voltmeter selector switch. h. One No. 3-phase, 4-wire, unbalanced load, dynamometer type, CT operated power factor meter. i. One No. 3-phase, 4-wire, unbalanced load, integrating type, KWH meter. j. One No. 3-phase, read type frequency meter flush pattern. The instruments shall have an accuracy class of 1.0 as per IS – 1248 E)Outgoing Motor Control circuits (02 Nos ): Each out going circuit shall consist of: Circuit Breakers:- : MCCB. Qty.: 01 No Model/Version :D sine series High DN3–630 N–(500-630) Amp- 01No. No. of poles :04 Rated Current: 630 Amp. Rated operational voltage:415 V + 15 % Rated frequency:50+/- 3 % Hz Ambient temperature:40C° Ultimate S.C Breaking Cap. at (415, ac, 50 Hz):50 KA Type of release :Thermal Magnetic Overload protection :0.8 –1 in adjustable Short Circuit protection: 3-6 in adjustable. Indicating Lamps shall be cluster LED type suitable to operate on 220 V AC. One No. 96 mm square dial ,flush pattern ,industrial grade , CT operated , ammeter of 0-630 Ampere capacity Three No. current transformers of required capacity and ratio One No. 3 –way and “OFF: ammeter selector switch One No.96 mm square dial, flush pattern. Industrial grade, voltmeter of 0-500 Volts capacity One No. 3-way and ‘OFF” voltmeter selector switch One No. suitable time tantalizer to record the time of operation F) Starters : 200 HP(FASD) Line Contactor Rating (AC3) :Not less than 400 Amps Delta Contactor Rating (AC3) :Not less than 300 Amps Star Contactor Rating (AC3) :Not less than 200 Amps Qty : 02 Nos G) Fault Analyzer= Digital motor protection relay with LCD display Protections =Under voltage, over voltage, under load, over load, locked rotor, currentunbalance, voltage unbalance, phase failure &phase reversal Display Parameter= Line voltage, phase voltage , line current, frequency, KW, KV, PF,fault history etc H)Auxiliary Feeder (01 No): Auxiliary feeder shall consist of following. One No MCCB, 100 Amp capacityasper IEC-60947-2 & IS-13947-2 with thermal release setting range of 0 - 100 amp having an integral magnetic thermal release for overload protection and shall also be provided with under load release to work on 220 Volts Indicating Lamps shall be cluster LED type suitable to operate on 220 V AC. One No 200 Amp capacity 96 mm Sq Dial flush pattern industrial type Ammeter One No. 3 –way and “OFF: ammeter selector switch One No.96 mm square dial, flush pattern. Industrial grade, voltmeter of 0-500 Volts capacity One No. 3-way and ‘OFF” voltmeter selector switch 03 No’s 200 -5A - 10 Volts suitable Current Transformer Coils |
955 | Modular cubical Soft starter panel:- The modular cubical type soft starter panel shall be fitted with 01 No. soft starters EMX4 with all necessary fittings suitable for safe operation of 150-200 HP motor . Details of Job:- Providing, fitting, testing and commissioning of 01 No. soft starters of 6-wire (inside Delta connection) suitable for 150-200 HP motor load. The soft starters shall be housed in a single panel of industrial type (Non –hazardous) totally enclosed, free standing cubicle type, dust and vermin proof, with IP54 sheet metal enclosure construction, and shall be internally wired and fitted with suitable rating copper bus-bars. The sheet metal enclosure of the soft starter shall be painted in enamel paint of standard quality of approved shade. The specifications of starter supplied shall be incompliance with latest relevant IEC/IEEE/IS Standards. The technical specifications /details of the soft starter shall be as under. i.Rated motor load=150-200 HP ii.Rated voltage= 380 to 480 volts (±10-15)% iii.Rated frequency = 50 Hz ±3% iv. Ambient Temperature = - 10 °C to + 45 °C v.Enclosure type = IP54 The Soft starter panel shall be provided with the indicating, metering and control devices. I. Digital Voltmeter and ampere meter II.Phase current indication with suitable ammeter and selector switch. III. Audio – visual alarms /fault indicators. IV.Alarms acknowledge /reset / test push buttons. V.Low watt consumption LED type indicating lamps. The ‘protection system ‘of soft starter shall be designed for protection /safety of motors against the following: I.Sudden Short circuit. II.Electrical Over load. III.Complete external fault. IV.Starting under locked or jammed conditions of rotor. V.Dry run of motor. VI.System under voltage. VII.System over voltage. VIII.Over current protection IX.Phase reversal. X.Thermal overload. XI.Phase loss to protect motor from single phasing. The soft starters shall be provided with all necessary controls / safety protections as required as per IS /IEC standards. |
956 | Main Service Line Providing and fitting of 400 Sq.MM, XPLE, PVC sheathed Armored Aluminum cable 3 1/2 core from Sub-stationto the main L.T control Panel in the Pump House as per requirement including all thimbling crimping taping etc.(100 Meters). The Cable shall conform to IS: 7098 part- I &II with latest amendments. The job includes laying and fitting of cable in air /underground as per the site conditions. The job includes crimping of the terminal ends of the cable with hydraulic crimping tool and providing and fitting of 300 amp capacity copper power conductor socketsand shall be as per relevant IS specifications/standards. |
957 | Internal Cabling Providing and fitting of 120 Sq.MM copper conductors, single core, PVC insulated, sheathed, 440 volts grade for inter-confectioning of the equipments like LT panel, voltage stabilizer, starter, motor etc. The job includes laying and fitting of suitable cable tray system in the station for laying/fitting of cable in air or as required as per the site condition with proper clamping etc. The job includes crimping of the terminal ends of the conductor with hydraulic crimping tool and providing and fitting of copper conductor sockets/thimbles of suitable size/ rating. The conductor shall be as per relevant IS specifications/standards. |
958 | Illuminations for water supply scheme premises:- Providing and fitting of 02 no. 9mtr long octagonal Hot Dip Galvanized steel Pole for installation of Luminaries with top diameter of 90 mm and bottom diameter of 200 mm. The bottom of the pole shall have to be provided and welded with a steel plate of 16 mm thick and 260 mm x 260 mm size and provided with 04 No’s of holes drilled for grouting bolts. The pole shall be fitted with MS ring fixture for fixing of Luminaries. The wiring for luminaries shall have to taken from inside for which required holes shall have to drilled. The Pole along with all the fixtures shall be coated with red oxide primer followed by two coats of Al paint. Luminaries:- 1) Flood Lights Providing and fitting of Four no. flood Lights on each pole to be installed in four directions on the above Octagonal poles and shall be of 120 watt LED type complete in all respect. The job shall include providing & fitting of 16 Amp ON-OFF/MCB Switches on junction box for each floodlight fitted at the bottom of pole 6 feet from the ground level with locking arrangement. 2)Cabling for Luminaries The cabling for luminaries shall be 4.0 mm Sq Cu wire (90mtrs) of standard quality (Havells/L&T/ABB) make in black and red as per ISI specifications. 3) Service Line for Luminaries The cabling shall be of 2 Core, 16 mm Sq, PVC Insulated Al Cable (90 mtrs) . The Cabling shall have to be laid underground through a PVC conduit of suitable size and the job includes cost on account of earth excavation and back filling of the excavated soil after laying of the cable. |
959 | Auto Voltage Stabilizer (5 KVA) The Auto Voltage Stabilizer shall be of Copper wound, 5 KVA Rating designed for an input Voltage of 90- Volt and Output Voltage of 230 Volt with Power Coated Enclosure. |
960 | 1. Power Inverter Providing and fitting of Power Inverter of 1400 VA Rating including providing of 200 AH Lead acid Battery of suitable rating complete in all respects. 2. Operator Room Lighting. i) providing and fitting and testing of (10 no’s) lighting to the Operator Room with lighting points in 2.5 sq mm PVC insulated copper wire including P/F of 5 Amp ON-OFF switches on Bakelite Sheet, 16 watt power saver and all other allied fixtures as required. The wiring shall be concealed. ii)Providing and fitting 0f (05 no’s)Heating Points to the operators roomin 4 sq mm PVC insulated copper wire including P/F of 16 Amp SS Combine on Bakelite Sheet. The wiring shall be concealed. 3. Pump House Luminaries Providing and fitting and testing of flood lights for Pump House with energy saving flood lights luminaries and high power cob LED light source and symmetric optics Jeta 30 Watt LED (04 Nos), 5000 KThe job includes all the required wiring and other required accessories complete in all respect. 4. Electric Fans Providing and fitting of 02 No. Electric Fans of ceiling mounted typecomplete with regulator / controlling switch, wiring in 2.5 sq.mm PVC insulated copper wire. |
961 | TOOL KIT For Maintenance: - The Tool Kit for maintenance as per detailed specification in cluase 56 of SBD |
962 | Providing of following items for operational staff for smooth functioning of the scheme: Bamboo link disconnecting/connecting rod with MS hook-02 No 20 feet longaluminum/steel ladder-01 No Snow shoes 06pairs. Matting comprising of 12 mm thermo cool, jute matting/ excel, floor blankets –300 sft each Bedding comprising ofmattress, razai,excel blanket, pillow – 04sets Cooking and bathroom items as 4 ltr pressure cooker, 2.8 ltr rice cooker, pan, aluminum cooking vessels – 02 No, steel plates – 04 No, Steel glass ( tumblers) – 04 No, cooking spoons – 02 No, Cups – 04 no, Plastic Jug, Electric heater, 20 ltr plastic buckets – 02 No, 1 ltr plastic mugs – 02 No, Chargeable lantern Ands lite make – 01 No, Two Burner Gas stove with domestic gas cylinder – 14 kg capacity complete with gas pipe and regulator.—01No Heat convector / Heating Blower – 02 No Plastic chairs of Samrudhi make (04 nos) and plastic table 01 No Uniform / track suit for operational staff-06 Nos. Fabrication., providing of angle Iron bed from 50x50x6mm angle Iron of size 8’x6’. The 8’x6’ rectangular frame is to be supported on 06 number legs of size 2". and two number diagonal crosses for proper supporting of 19mm plywood .The job includes paintingof red oxide paint of the bed |
963 | Providing, laying & fixing with adhesive/bonding material of insulation rubber mats on the floor of the pump house, covering area around electro-mechanical machinery for safeguarding the life & limb of the workmen due to possible leakage of current & short circuit. The floor surface shall be made good & shall be free from dust, grease, foreign material & moisture free. The mats shall be as per IS 15652:2006 & shall have the following specifications: - Composition:Rubber (synthetic mats for electrical purpose) Thickness:- 2.50mm Size : - 1M wide. The rubber mats shall be accepted with manufacturers test certificate. |
964 | Providing/Fitting of80 MM Dia flexible convas sleeve/conduit for carrying cables of different sizes. |
965 | Fabrication providing & fitting of split type MS Clamps 8mm thick,6” wide and 2.5 feet long for lowering of column pipes. The job includes Providing & tightening of 03 No appropriate size nuts and bolts no either side along with5 mtr ¾” dia sling rope. |
966 | Providing / fitting / testing of ABC MAP (Mon ammonium Phosphate) fire extinguisher with fallowing specifications Chrome plated brass valve Chrome plated brass discharge nozzle Skirted steel cylinder Rechargeable Inter changeable components Heavy duty steel carrying handle Stainless steel house trap Steel forked wall bracket Capacity 6 Kgs Included is fabrication of angle iron base frame wall mount type with brackets as per site requirement. |
967 | Providing of set of 06 No 9.5-liter capacity GI buckets painted in post office red color with prior coat of red oxide primer & written with white paint “FIRE” & mounted on angle iron frame with brackets of appropriate size & capacity including cost of providing / filling of sand etc. Included is providing First Aid box as approved by Indian red cross conforming to IS 2217 & amended till date |
968 | Providing, fitting, testing and commissioning of APFC Panel (120 KVAr) (FULLY AUTOMATIC POWER FACTOR CONTROLLER)with the following specifications: The Panel shall be totally enclosed, free standing type, sheet metal enclosed, dust & vermin proof, IP - 54 enclosures and shall be suitable for AC, 3 – phase, Voltage & Frequency as 415 ± 15% Volts and 50±3% Hz respectively and internally wired. The panel shall be applied with enamel paint of standard quality and of approved shade. The panel shall be extensible type and comprises of the material with specifications as specified in Annexure A . The Control panel shall be fabricated out of 14 SWG cold rolled steel plates & properly supported using angles & channels. The Panels shall be divided into convenient continuous line. The whole panel shall be mounted on a base frame made out of suitable structural channels /beams. Joints of any kind in sheet shall be seam welded, all welding slag grounded off and welding pit wiped smooth with plumber metal. Compartment doors shall be inter-locked with the switch unit in such a way that the door shall not open when the feeder switch shall be ON. The panel shall be fitted with the same family of switches for various ratings with a view to ensure uniformity of design, maintenance and replacements. A horizontal wire way with screwed cover shall be provided at the top/bottom to take inter-connecting control wiring connection between different vertical sections. Separate and adequate compartments shall be provided for accommodating instruments, indicating lamps, control contactors and control fuses etc. Annexure – A APFC Panel ( 120 kVAr ) DESCRIPTION Incomer RatingQty TP MCCB, 35KA, TM O/l & S/C Trip release 160 A 1 Control MCB, 10KA, C Curve6 A 1 Indication Lights, 230V ACR/Y/B3 Digital APFC Relay,1 Phase, MP Based, 230V Aux. Supply 8 stage 1 A/M Selector Switch for Auto & Manual6A 1 Capacitor Bank20 KVAR4 set TP MCCB, 10 KA, TM O/L & S/C release 63 A4 Capacitor Duty Power Contactor, 220V AC Coil 20 kVAr4 Power Capacitor, Cyl. Capacitor- HD Plus, 440V AC 20 kVAr4 Illuminated Switch For Manual Switching & Step IndicationR 4 Capacitor Bank 10 KVA 2 set TP MCCB, 10 KA, TM O/L & S/C release 25 A 2 set Capacitor Duty Power Contactor, 220V AC Coil10 kVAr 2 Power Capacitor, Cyl. Capacitor- HD Plus, 440V AC10 kVAr 2 Illuminated Switch For Manual Switching & Step IndicationR2 Capacitor Bank 5KVAR2 set TP MCCB, 10 KA, TM O/L & S/C release20 A 2 Capacitor Duty Power Contactor, 220V AC Coil5 kVAr 2 Power Capacitor, Cyl. Capacitor- HD Plus, 440V AC 5 kVAr 2 Illuminated Switch For Manual Switching & Step Indication R2 Capacitor Bank3KVAR2 set TP MCCB, 10 KA, C curve10 A2 TP Power contactor 09 A2 Power Capacitor, Cyl. Capacitor- HD Plus, 440V AC 03 kVAr2 Illuminated Switch For Manual Switching & Step IndicationR 2 Capacitor Bank2kVAR2 set TP MCCB, 10 KA, TM O/L & S/C release 9 A 2 TP Power contactor 06A 2 Power Capacitor, Cyl. Capacitor- HD Plus, 440V AC02 kVAr2 Illuminated Switch For Manual Switching & Step Indication R 2 ENCLOSURE with CRCA Sheet Steel & Cu Bus Bar |
969 | P/F/Testing of one No MCCB, Manually operated, 630 Amp , 50 Ka Breaking capacity with overload and short circuit protection of L and T/ Havel’smake. The switch shall be enclosed in dust proof sheet enclosure shall be suitable for 3 phase AC supply , 50 HZ frequency and fitted near existing sub-station. The equipment comprises of the material 400 Amp MCCB-4pole Breaking Cap—50 KA Voltmeter -0-500 V with selector switch 400 Amp Copper bursars Neon indicating lamps suitable for 220 V AC Duty –Outdoor |
970 | Providing, Installation, Fitting, Testing and Commissioning of 300 KVA D.G Setas per following: TECHNICAL SPECIFICATIONS:- Supply of 300 KVA 3- Phase DG Set suitable for standard NTP and 60 % relative humidity. The DG Set shall be comprising of diesel engine and alternator coupled together with heavy duty flexible coupling and mounted on MS base frame along with standard accessories, control panel, battery, anti – vibration pads and M.S. canopy duly painted conforming to noise pollution specifications /requirements of environmental protection rules 1986 as laid down by Ministry of Environmental protection and forest, read with GSR- 371 (E) date 17-02-2002 & GSR 520 (E) date 01-07-2003 in respect of emission norms for the Engine and in respect of noise level for the D.G Sets for supplies read with up to date amendments and as applicable at time of supply. The engine shall conform to IS / 10000/ BS -649 / BSS 5514. The DG set should be rated for continuous duty with overload provision of 10% for the period not exceeding one hour in 12 hours. The specifications are as under:- Alternator : The alternator shall be self – regulated for 300KVA rating and conforming to IS 13364 (II) and shall be brushless. The alternator shall be scratch protected, drip proof with IP-23 degree of protection as per IS 4691/85 and shall be two bearing type B-3 construction, foot mounted ensuring rigidity epoxy gel coated, positive voltage built up compact design with high performance AVR suitable for continuous and trouble free operation. Output rating at = 250KVAstandard operating conditions Rated Speed = 1500 RPM Type = 3 phase Brush less Efficiency=88 % or above Voltage= 415 V ± 3% at 50 Hz. Power factor = 0.80 Alternator winding = Copper (PVC insulated-H class) Diesel Engine (prime mover): The engine is diesel driven to develop requisite BHP at 1500 RPM for the alternator rated as above at an altitude of 1764 (AMSL) with ambient temperature ranging from (-) 10° to (+) 40 °C under 60% humidity Conditions: Type = Turbo charged Gen set rating = 300 KVA standard operating conditions Speed = 1500 RPM Control = ECM-controlled Method of start = Battery operated Cooling System = Air cooled( Preferably) Accessories : Besides all accessories/ standard equipment to make the Engine complete in all respects and ready for use with following equipments Anti Vibration Mountings Cold starting unit Safety control against low lube oil pressure and high cooling water temperature along with tripping FUEL TANK: Suitable capacity floor mounted type made of MS sheet and duty painted. The fuel tank shall fitted with return connections, air vent, drain valve, level indicator and fuel pipes, safety control for high canopy temp. BATTERY: Suitable battery with Rack and cables along with lead terminals connected with charging dynamo and cut out fitted with 24 volts-starting system. Engine instrument panel It shall be fitted with starting switch, with foys, lube oil, guage, temp & pressure guage, speedometer and hour meter etc. Standard Control Panel : It shall be fabricated out of powder coated sheet metal preheated and aesthetically finished. The control panel shall be totally enclosed, dust, vermin proof, floor mounted with IP-53 degree of protection as per AS 2147: 62. The panel control shall consist of following instruments:- (0-600) V-A.C Voltmeter(s) of class 1.5 accuracy with four position selector switch for 3 – phase D.G. Set A.C – Ammeter of class 1.5 accuracy of suitable rating for 250KVA DG set. HRC fuse of suitable rating for 300KVA DG set MCCB / MCB‘s of suitable rating for 300KVA DG set. Frequency meter digital type of suitable rating for 300KVA DG set. Energy meter of suitable rating for 300KVA DG set. Power factor meter digital type of suitable rating for 300KVA DG set Push button switch for ON & OFF operation Pilot lamps (3 No’s) of suitable rating for 300KVA DG set Instrument and control fuses Battery charger connected to voltage regulator voltmeter and ammeter for charging battery from the mains. This shall be in addition to the battery charging alternator fitted on the engine instrument and control fuses. All the above components shall be properly mounted duly wired and labeled. Suitable terminals are Provided for panel incoming and outgoing connections. Canopy: M.S canopy of suitable thickness to with stand snow load, compact and aesthetically superior duly painted and able to control noise pollution as per requirements of environmental (protection) rules Technical literature / catalogue shall be provided. The following jobs are also included in the scope of work: a) Providing and fitting of Battery charger / inverter connected to voltage regulator voltmeter and ammeter for charging battery from the mains. This shall be in addition to the battery charging alternator fitted on the engine instrument and control fuses. b) Providing and fitting of 300 Sq.MM, XPLE, PVC sheathed ArmoredAluminum cable single core from DG set panel to the main L.T control Panel in the Pump House as per requirement including all thimbling crimping taping etc.(50Meters) c) P/F ofDowels/reputed make Aluminium thimbles duly crimped with a hydraulic crimping tool and properly insulated with tape to avoid air flow inside the insulation.(12jobs) d) Requisite size Concrete block for resting of DG set e) Standard tool set for DG set maintenance The job also includes first filling of HSD 210 ltrsand testing on full load at site. |
971 | Details of Angle Iron Canopy for 300 DG Set housed under one Roof:- CONCRETE BED BLOCK WITH RAMP :- Earth work in excavation by manual means in trenches for foundation, drains, pipes, cables (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and reaming of bottom lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed.(All kinds of soil 01 meter from cutting edge) |
972 | Providing and laying hand packed stone soling |
973 | Centering and shuttering including strutting , propping etc. and removal of form work for Foundation , footings , bases for columns |
974 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering . all work upto plinth level with 1 : 2 : 4 mix (1 cement , 2 coarse sand , 4 graded stone aggregate 20mm nominal size) |
975 | P/Laying/Applying of 15 mm thick plaster in 1:4 ( cement : sand ) mix over the whole expose surface |
976 | P/Fabrication/Errection and hoisting of:- A) Verticle Posts: 125 mm dia 5 mm thick 10 feet long MS pipe - 12 No 300 x 300 mm x 10 mm thick MS base plate- 12 No 300 x 300 mm x 10 mm thick MS matching plates to be grouted in cement concrete block with 15 mm dia bolts projecting out of concrete and welded to the grouted plate on the other side cw suitable size nuts and washers – 12No 150 x 150 mm x 6 mm thick MSplates to be welded on top of posts and their matching plates to be welded on the beams, - 24 No = 744.8 kgs B)ISA (50x50x6) mm Double section for the fixing vertical Posts at the top and for the tie beams:- Angle for Fixing vertical Posts=2x2(9m+4m)=52 R.m @4.5 kg / rmt=234 Kgs Tie Beams =¯¯5x2 x5m= 50 m @4.5 kg / rmt=225 Kgs Truss: ISA (50x50x6) mm double section for truss beam,King Post,Strutts and rafter etc [5x2 ( 2.5m +2.925m +1.833m+1m+0.694m+0.50m)2 +5x2x1.52m=204.16 R.m @4.5 kg / rmt =918.72 Kgs Gusset plates in MS 70 No.150 x 200 x 6mm=0.0126 cum@ 7856Kg/cum= 98.98 Kg. C)Perlins (40*40*5) = 12¯× 10m= 120mtrs @ 3.00 kg/m = 360 Kgs Total Iron:(744.8+234+225+918.72+98.98 +360)Kgs= 2581.5 kg D)Painting of whole shed with one coat of red oxide and two coats of enamel paint after through surface cleaning by using proper grade of emery paper.The job includes cutting, welding, hoisting etc as per site requirement. |
977 | Providing and fitting of CGI Green color coated sheeting for roofing of shed in 26 SWG(0.50mm) gauge along with P/F of j-hookswith nuts/washers and plane sheeting for Ridge .=2¯x8mx3m+8mx0.6m = 52.8S.m |
978 | Supply , installation , commissioning and creation of pole mounted, outdoor type Electric Sub Station as per the technical specifications given here under - Specifications conforming to IS: 1180 (Part 1) 2014 with latest amendments. Type: HT/LT Transformer Type of cooling: ONAN. Operating conditions: Input =11000 volts Output =433 volts AC supply in 3- phase. Terminals: Input=3 No. HT bush rods with insulators, washer, nuts etc. Output=4 No. LT bush rods switch insulators, washers, nuts etc. Core: The core shall be of high permeability to reduce core losses and the strips shall be of suitable size and gauge. Transformer Coils: Suitable number of HT and LT coils in each leg of the core. The transformer coils shall be fabricated out of superior quality aluminum wire/strips, properly wound. The HT transformer is completely filled with suitable grade transformer oil up to required level. The job includes carriage, and all leads and lifts involved. The HT transformer shall be of reputed make from an ISO certified company as per relevant standards and a test certificate shall be provided before installation. The transformer shall also be provided with breather fill with silica jel crystals, conservator with oil level indicator, explosion vet and adequate radiator fins/ Tubes. The impedance of transformer shall be as per IS: 1180 (Part 1) 2014 with latest amendments. NOTE: The scope of the work shall include obtaining of necessary inspection/clearance certificate from the concerned department for all the required equipment. The testing and commissioning shall be completed only after obtaining above certificate. |
979 | HT Cable for Tapping Providing and fitting of 95 Sq.MM, 3 -core, XLPE HT (ABC) Aerial Bunched cableThe cable shall be fitted from nearby HT line up to the electric sub-station. The Cable shall conform to IS-14255 and IS: 7098 part- II with latest amendments The job includes crimping of terminal ends of the cable by hydraulic crimping tool and providing and fitting of suitable cable kits as required and shall be as per relevant IS specifications/standards. |
980 | 32. WSS Gundbal Androosa(Part Gundbal Only) (Adv. Cost Rs. 29,13,662/-) |
981 | Supply, Installation, Testing & Commissioning of Submersible Pumping Unitas per IS 8034 with following specification are as under : PUMP : Speed= 2900 Rpm Type of pump = Mixed flow. Type of fluid to be handled=Clear Water MOTOR:- Method ofstarting = Star – Delta Speed = 3000 (Sync). Frequency= 50 ± 3 % Hz Working Voltage= 380-415 ± 15% V, 03 phase Efficiency = Not less than 90% Note: Providing of test certificate & Characteristic Curve of pumping equipment is compulsory and pumping unit is to be approved from the concerned Sub Divisional office before procuring. Detailed specifications as per cluase 1 SBD The mainspecicifications of pumping unit are given below: Motor Rating: 15 HP |
982 | Fabrication, providing, fitting and lowering ofcolumn pipe conforming to IS: 1239 of length 10 Rft into the 200/ 250/300 mm casing dia. production well up to the desired depth ; The job includes Providing and welding of flanges conforming toIS: 6392, Table-17 and PN 16 to these pipes and welding of flanges in two layers to make the flanged joint strong and leak proof. The pipe of 10 ft length is to be weld on both sides with flanges using welding rod of reputed make. The job includes all types of skilled labours, arrangement of power supply/ diesel Generator set etc required for the job including P/F of suitable size nuts bolts and R.I Gasket in the flanged joints of column pipes. The job further includes cutting of 2 no. rectangular cable slots in each flange. Size: DN 65 Class: B (Medium) |
983 | Providing/supplying and fitting ofG.I flanged Rising Main at site. The Pipe shall be hot dip Galvanized, class-C confirming to IS 1239. The job includes providing and fitting of M.S Flanges conforming to BIS 6392/1997 Table 17 (Rating PN16).s. The rising main is to be laid as per the instructions of the engineer in charge and site requirement and details as per cluase 8 of SBD Size : DN80 Class: C (Heavy) |
984 | Earth work in bulk excavation by mechanical means in trenches for foundations, drains, pipes, cables etc (not exceeding 1.5m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan , including dressing of sides and reaming of bottom lift upto 1.5 m , including getting out excavated earth and disposal of surplus excavated earth as directed. (All kinds of soil 01 meter from cutting edge) |
985 | Filling available excavated earth in trenches, plinth, sides of foundation etc.in layers not exceeding 20 cm in depth , consolidating each deposited layer by reaming and watering , lead upto 50 m and lift upto 1.5m. |
986 | Extra for every additional lift of 1.5 m or part thereof in excavation /banking excavated or stacked materialin all kinds of soil |
987 | Providing and laying of stone soling including manual compaction |
988 | Centering and shuttering including strutting , propping etc. and removal of form work for Foundation , footings , bases for columns |
989 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering . all work upto plinth level with 1: 2 : 4 mix ( 1 cement , 2 coarse sand , 4 graded stone aggregate 20mm nominal size) |
990 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering . all work upto plinth level with 1: 4: 8 mix ( 1 cement , 4 coarse sand , 8 graded stone aggregate 40mm nominal size) |
991 | 12 mm thick cement plaster of mix 1:4( 1 cement , 4 fine sand ) |
992 | Steel reinforcement for RCC work including straightening, cutting, bending, placinng in position and binding all complete upto plinth level Thermomechanically treated bars of grage FE-500D or more |
993 | Providing and laying in position cement concrete of specified grade of reinforcement cement concreteincluding curing but excluding the cost of centring and shuttering . finishing and reinforcement all work upto plinth level with 1: 1.5 : 3mix ( 1 cement , 1.5 coarse sand , 4 graded stone aggregate 20mm nominal size) |
994 | Fabrication, providing and fitting of split type MS clamps10 mm thick, 2 ft long and 3 inch wide for lowering and holding of pumping unit fitted. The job includes the cost of required size of nuts and bolts. Size: 65mm |
995 | Fabrication, Providing and fitting of90-120 degree bend/elbowto be fabricated out ofG.I pipeand flanged on both ends ato make it leak proof. The flanges shall be M.S Flanges conforming to BIS 6392/1997 Table 17 (Rating PN16) and welded on both sides. The job includes nuts, bolts, gaskets etc as per site requirement. Size:DN 80 Class: C |
996 | Providing and fitting of 300mm in length GI reducer bend flanged on both sides, flange conforming to Table-17 (PN16) to be fitted with the column pipe/delivery manifold of submersible pumping unit to join Rising-main and column pipe/delivery manifold. The flange welding shall be carried out in double layers using reputed make electrodes from inside and outside of pipe to form strong welding joint. Size: 80mm-65mm , Class: C |
997 | Fabrication, providing and fitting of T -junction out of 1M of pipe with 1ft each arm. The job includes all types of skilled labour,arrangement of power supply/diesel generator set etc required for the job including P/F of table 17 flanges, suitable size nuts, bolts and RI gasket in the flanged joints (Rest specification as per clause 09 of SBD). Size: 80mm, Class: C class |
998 | Providing and fitting of, Ductile Iron double flanged, non-rising spindle soft seatedglandless gate/ sluice valves as per IS14846 for regulating the water supply outside the pumping units . Size 80 MMPN1.6 Manufacture test certificate to be appended. Rest ofspecification as per Cluase 12of technical anexure of SBD |
999 | Providing and fitting ofDuctile Iron double flanged, Slanted seatswing check valve( NRV) as per IS 5312. Manufacture test certificate to be appended. Rest ofspecification as per Cluase 13of technical anexure of SBD Size 80 MMPN1.6 |
1000 | Providing, fitting , testing and commissioning of50mm diameter ARV (Air Release valve ) as per IS 14845 to be fitted toG.Irising Main. Manufacture test certificate to be appended. Rest ofspecification as per Cluase 14of SBD |
1001 | Fabrication of gravel Hooper for proper feeding of gravels to the borewell andplatform to bear the load of pumping unit, column pipes etc by way of providing and fitting of Steel work welded in built up sections/framed work, including cutting , hoisting , fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. The job involves following steel details: In stringers, treads, landings etc of stair cases including use of chequered plate wherever required , all complete |
1002 | In grating , frames , guard bar , ladder , railings, brackets, gates and similar works |
1003 | Providing and fitting ofM.S 4 inch hinges -6 no and M.S handle heavy -8no., Anchor bolts with nuts (M16) of 0.3 m long= 04 No. Metallic strip (350mm×50mm×3mm) = 02 No. |
1004 | Fabrication of gantry mechanism/CGI shed/ Angle iron bed by way of providing Structural steel in built up sections , trusses and framed work, including cutting , hoisting , fixing in position and applying a priming coat of approved steel primer all complete welded. |
1005 | Providing, installation andtestingof manual type triple spur gearchain pulley block along with monorail gearedtravelling trolleyhaving following features : Make= Reputed make Capacity =2ton No. Of load chain falls = 2 or above Min. Height of lift = 6 M Manufacture test certificate to be appended. Rest ofspecification as per Cluase 24of technical anexure of SBD |
1006 | Creation of pope mounted , outdoor type Electric Sub Stationby way ofS/I/T/C of 11/0.433 KVA , 3 Phase Distribution Transformer with Bimetallic Terminal connectors Energy level -2 Aluminum wound Specifications conforming to IS : 1180 (Part 1) 2014 with latest amendments ertificate Rating:63KVA HT Transformer, 3 phase (Level 2). Manufactures test certicicate to be apended and rest of specification as per cluase 26 of SBD NOTE: The scope of the work shall include obtaining of necessary inspection/clearance certificate from the concerned department for all the required equipment. The testing and commissioning shall be completed only after obtaining above certificate |
1007 | Providing and fittingG.I Channel /Angle/ Flat of sizes including clamps |
1008 | Supply, Installation, Testing and commissioning of Polymeric Gang operated Air break switch, outdoor type, triple pole, suitable for vertical installation, single break provided with locking arrangement at both ON and OFF position consisting ofHT post double insulator, copper or copper alloy high pressure heavy contact assembly, rod with bearings , operating handle and 2 length of 32mm dia. GI pipe conforming to IS 1818 1961, 06 No. of insulators, rated voltage 11KV 200A complete as per IS specs. |
1009 | Supply, Installation, Testing and commissioning of 11KVpolymer fuses SetHorn Gap3-phase 200 Asuitable for vertical installation . |
1010 | Supply, Installation, Testing and commissioning ofGapless Surgearrestor station class, 10KA, 9KV, LA With polymer housing , Station Type . |
1011 | Supply and fitting of 11 KV polymeric composite pin insulator 12 KV, 5KN, Lighting impulse 75KV Positive, and 80 KV Negative , creepagedistance 320 mm |
1012 | Supply, installation, errection of9 mtrs long ST- 410 (sp-33) . The job further includes drilling of holes for installation of various accessories .wherever required. The job further includes GI wire earthing of pole as per REC standard. |
1013 | P/F of Galvanized nuts, bolts of various sizes as per site requirement. |
1014 | P/F Danger Plate with clamps |
1015 | Providing and fixing G.I Barbed wire for anti climbing |
1016 | Providing and fixing of anti climbing devices with clamps |
1017 | Providing and fitting of Galvanized stay set with 50 X 8 mm Stay Clamp , Guy insulator (2no.), Anchor plate (200X200X6mm) , nuts and bolts , 2 N0- turn buckle , 1.8 m long , 16 mm diameter solid G.I stay rod & 7/3.15 mm dia. G.I stranded wire complete. |
1018 | Painting of poles Red oxide |
1019 | Painting of poles Aluminum paint |
1020 | Providing and fitting of ACSR as per IS 398 (part-2) 1996 for 50 sq.mmACSR (Galvanised steel reinforced) for fitment of various accessories |
1021 | Supply, Installation and Testing of 35 Sq mm XLPE Aluminum H.Tcable (ABC type ) of 11 KV grade with following specs. Size (cross sectional area in sq mm) = 3×35 with reinforced wire Phases:Red, Yellow, Blue |
1022 | Providing and fitting of Anchoring clampscomprising clamp body , plastic wedge, steel bill bracket , straps and buckles or nuts and bolts required for holding of 3 – Core , 35 Sq. mm H.T AB Cable. |
1023 | P/F of 11 KV cable termination kit for connecting 35 Sq mm XLPE cable (ABC type) with the existing HT line near tapping point andHT transformer. |
1024 | Providing and fitting of LT Distribution box for HT transformer with MCCB For incomer and SFU for out going circuits . Capacity of transformer: 63KVA |
1025 | Fabrication, Providing and fitting of 20 HP Modularmotor control panel of appropriate size fabricated out of 14 SWG sheet having required openings/vents and protection Class : IP-55 & fitted with accessories: Rest specification as per SBD clause 43E |
1026 | Providing, fitting, testing and commissioning ofvoltage stabilizeras per specifications below: Type of voltage controller: Manually operated copper wound, 3-phase, AC power supply Rest technincal specification as per cluase 45 of SBD Rating::50KVA |
1027 | Providing and fitting of 3-Core flatsubmersible copper cable conforming to IS: 694 (Part 1st) – 1964 & IS: 694 (Part 2nd) - 1964 for Submersible Pumping Unit and other electrical Equipments . The cable connections terminal shall be fitted with copper thimbles of required size. Size: 16sq.mm |
1028 | Providing and Fitting of 2/3 /3.5/Core, XLPE, 1.1KV and 11KV grade Armoured Aluminium Cable conforming to IS: 7098 part 1st as service line from the HT transformer to control panel including necessary thimbling, crimping, taping etc. NOTE:- The cable terminal ends for connection to switchgear at various requisite points shall be Al. Thimbles of dowel’s make and of appropriate size and connected by hydraulic crimp tool only. Rest Specifications as per clause 71 of SBD i) 10sqmm, 2 core LT 1.1KV |
1029 | ii) 50sqmm, 3.5 core LT 1.1 KV |
1030 | Providing and Fitting of single-Core, copper pvc insulated Cable,conforming to IS: 694 part 1st for internal connections with crimping, taping etc. NOTE:- The cable terminal ends for connection to switchgear at various requisite points shall be copper Thimbled and of appropriate size and connected by hydraulic crimp tool only. Single core PVC insulated 25sqmm Rest technical specification as per cluase 67 of SBD |
1031 | P/I of earthing station for substation, LT panel and stabilizer comprising of company fabricated earthing electrode as per IS: 3043. The job includes Auguring of bore of required dia/depth for installation of electrode along with backfill compound mixed with soil and all other items required thereof for achieving the best result. The job includes connecting of electric gadgets through GI strip as per relevant standards. Safe earthing electrode size:80 mm dia , Length :2000 mm Back fill compound :30 kg |
1032 | Supply, installation of 6 kg co2 type fire extinguisher manufactured as per IS:15683 OF 2006 with IS mark and comply with DGMS(Approval) . Rest technical specification as per cluase 50 of SBD |
1033 | Illumination of Premises: Providing and erection of 9 Mtr long Hot Dip Galvanized octagonal pole (single Section) with bottom 150mm, top 75mm wide, thickness 3mm with 70 Microns Zinc coating having inside arrangement for providing of power connection along with following items. 1) 3 Way Terminal Connector 20 Amp. 2) 3 No MCB 8 Amp. Rest technical specification as per cluase 51 of SBD |
1034 | Providing, installation, testing and commissioning of area lighting 120 Watt LED (Street Light Type) on top of octagonal pole . Rest technical specification as per cluase 52 of SBD |
1035 | Providing, Installation and testing of 2KVA fully automatic voltage stabilizer with input voltage 70-240 V and output 220 V. The stabilizer shall be installed and connected to the electric circuit as per location provided by site incharge. |
1036 | Supply, installation, Testing & commissioning of 1000VA Full Sine wave power inverter (Make: Reputed) including Providing / Installation of 12V, 180AH Tubular inverter Battery with trolley and cover. (Make: Reputed) with 2-core 6mm2 Cu wiring as per site requirement along with other accessories like SS-Combine (02 No’s), 3-pin plugs etc of reputed make for proper fitment and installation of the item. |
1037 | Providing, laying & fixing with adhesive/bonding material of insulation rubber mats on the floor of the pump house, covering area around electro-mechanical machinery for safeguarding the life & limb of the workmen due to possible leakage of current & short circuit. The floor surface shall be made good & shall be free from dust, grease, foreign material & moisture free. The mats shall be as per IS 15652:2006 & shall have the following specifications: - Composition: Rubber (synthetic mats for electrical purpose) Thickness: - 2.5mm Size: - 1M wide. The rubber mats shall be accepted with manufacturers test certificate. |
1038 | TOOL KIT For Maintenance: - The Tool Kit for maintenance shall comprise all the items as per Cluase 57of technical anexure of SBD with laid down specifications. |
1039 | Providing and fitting of 19 mm thick multilayered ply sheet of size 6 x 3 feet , 2 nos including cutting , fixingall complete including painting of the play sheet by one coat of primer and two coats of enamel paint. (2 jobs) |
1040 | Providing of good qualityconvence and utility items. Technical specification and item details are as per cluase 58 of SBD. |
1041 | Providing of solar/ electrical lantern chargeable on both solar & electrical 220v supply. |
1042 | Providing of bamboo ladders 18 feet long along with 15 feet long Link rods and HT Glove pair (01 No each) |
1043 | Providing of 1 KW heat convector for operators for winter season. |
1044 | Providing and fitting of 01 No. LED (scroll type) sign board fabricated out of stainless steel and metal showing the names of water supply scheme and the Department. Size:6’×1’6” (Two jobs) |
1045 | Providing and fitting of 01 No. angle iron/sheet metal board duly painted showing various specifications of the mechanical and electrical equipments installed at site. Size: 4’×6’ out MS ANGLE OF 40X 40X 5of 36 rft and MS sheet of 1 mmthicktotal weight of50.16 kgs (Two Jobs) |
1046 | Providing ridges or hips of width 60 cm overall with plain G.S sheets fixed with polymer coated J- Or L- hooks , Bolts and nuts 8 mm dia. G.I limpet and bitumen washers complete 0.63 mm thick with zinc coating not less than 275 gram/sq.m |
1047 | Providing and fixing plain eaves boarding 2nd class Kail wood ( 250 x 32 mm nomonal size) |
1048 | Providing and fixing of PUF Enclosure in Walls. Rest Technical specification as per cluase73of SBD |
1049 | Providing corrugated G.S Sheet roofing including vertical/ curved surface fixed with polymer coated J or L Hooks , bolts and nuts 8 mm dia. diameter with bitumen and G.I limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete ( upto any pitch in horizontal /vertical or curved surface) excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 1.25 mm thick with zinc coating not less than 350 gram/m2 |
1050 | Providing and fixing aluminum work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixed with dash fastener of required dia. and size including necessary filling up of gaps at junctions i.e, at top, bottom and sides with required EPDM rubber / neoprene gasket felt etc. Aluminum sections shall be smooth, rust free, straight, mitered and jointed mechanically wherever required including cleat angle, Aluminum snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge (glazing, panelling and dash fasteners to be paid for separately.) powder coated aluminum (minimum thickness of powder coated 50 microns) |
1051 | Providing and fixing 12mm thick pre laminated particle board flat pressed three layer or graded wood particle board (conforming to IS:12823 Grade-I type-II) in paneling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in charge. Pre-laminated particle board with decorative lamination on one side and balancing lamination on other side. |
1052 | Providing and fixing aluminum casement windows fastener of required length for aluminum windows with necessary screws etc. Complete Powder coated minimum thickness 50 micron aluminum |
1053 | Providing and fixing aluminum round shape handle of outer dia 100mmwith SS screws etc. Complete as per direction of Engineer-in-charge Powder coated minimum thickness 50 micron aluminum |
1054 | Providing and fixing glazing in aluminum door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer in-charge.With floating glass panes of 4.0 mm thickness (weight not less than 10.00 kg / sqm) |
1055 | Surface dressing of the ground including removing vegetation and in-equalities not exceeding 15 cm deep and disposal of rubbish, lead upto 50 m and lift upto .5 m in -All kinds of soil |
1056 | Carriage of sand , stone aggregate by mechanical transportincluding loading , unloadingand stacking (average distance-5km) |
1057 | Carriage of soling stone by mechanical transportincluding loading , unloadingand stacking (average distance-5km) |
1058 | Carriage of cement/steel/CGI sheet/GI pipes below 100mm dia and other heavy materials by mechanicaltransportincluding loading , unloadingand stacking (average distance -25Km) |