| 1 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.-All kinds of soil cum |
| 2 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. -All kinds of soil |
| 3 | Supplying and filling in plinth, under floor, foundations etc. with sand (fine) from local quarry with all lifts including spreading in horizontal layers, watering, grading to required slope, ramming, consolidating and compacting each layer by using plate compactor or by any suitable method complete. |
| 4 | Providing and laying in position cement concrete of specified grade excluding the cost of centring andshuttering - All work upto plinth level:(i) 1:3:6( 1 Cement: 3 fine sand : 6 graded well burnt brick aggregate 40 mm nominal size) |
| 5 | Providing and laying in position specified grade ofreinforced cement concrete excluding the cost ofcentring, shuttering, finishing and reinforcement--All work upto plinth level: i)1:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stoneaggregate 20 mm nominal size) |
| 6 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto floor five level excluding the cost of centring, shuttering, finishing and reinforcement-i)1:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stone aggregate 20 mm nominal size) |
| 7 | Reinforced cement concrete work in walls (anythickness), including attached pilasters, buttresses,plinth and skirting courses, fillets, columns, pillars,piers, abutments, posts and struts etc. upto floor five level excluding cost of centring, shuttering, finishingand reinforcement- i)1:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stone aggregate 20 mm nominal size) |
| 8 | Reinforcement for R.C.C. work including straightening, A) cutting, bending, placing in position and binding all complete upto plinth level. i)Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 9 | B) cutting, bending, placing in position and binding all complete above plinth level.i)Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 10 | Centering shuttering including struttings, propping etc. and removal of form work for: (i) Foundations, footings, bases for columns etc. for massconcrete with timber plank |
| 11 | ii)Lintels, beams, plinth beams, girders, bressumers and cantilevers with wooden plank |
| 12 | iii)Columns, Pillars, Piers, Abutments, Posts and Struts with shuttering ply |
| 13 | First class brick work in foundation and plinthincluding cost of all materials as required complete:-i) In cement mortar 1:6 ( 1 cement : 6 fine sand ). |
| 14 | Half brick masonry work with first class bricks insuperstructure upto floor five level including cost ofall materials as required complete:- i)In cement mortar 1:4 ( 1 cement : 4 fine sand ). |
| 15 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. all complete. i)Fixed to openings /wooden frames with rawl plugs screws etc. |
| 16 | 12 mm cement plaster of mix. i)Cement mortar 1:4 (1 cement : 4 fine sand) |
| 17 | Neat cement punning |
| 18 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying apriming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. (i) Hot finished welded type tubes |
| 19 | Providing and fixing M.S. round holding down bolts with nuts and wahser plates complete as per standard design. |
| 20 | Providing and fixing MS bolts including nuts andwashers complete as per standard design:- (i) Upto 300mm length. |
| 21 | Providing and fixing precoated galvanised iron profilesheets (size, shape and pitch of corrugation as approvedby Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS:277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 22 | Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+ 0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS:277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 1518 microns using self drilling/ self tapping screws complete for Ridges/Valley/Gutter/Flashing of width 600mm. metre |
| 23 | Providing and fixing chequered terrazo tiles 22 mm thick with graded marble chips of size upto 6 mm, laid on floors, footpath & courtyard on 20 mm thick bed of cement mortar 1 : 4 ( 1 cement : 4 fine sand ) jointed with neat cement slurry mixed with pigment to match the shade of tiles including rubbing and polishing complete. (i) Dark shade pigment using ordinary cement |
| 24 | Finishing walls with acrylic smooth exterior paint of required shade of approved brand and manufacture[Payment shall be made after submission of Test Certificate issued by the Manufacturer] : i)New work ( two or more coats applied @ 1.67 litre/10 sqmover and including priming coat of exterior primerapplied @ 2.20 kg/10 sqm) |
| 25 | Applying priming coat [Payment shall be made aftersubmission of Test Certificate issued by theManufacturer] : (i) With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works |
| 26 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade [Payment shall be made after submission of Test Certificate issued by the Manufacturer]:Two or more coats on new work |