Repair, Maintenance And Rewiring Of Internal Point Wiring, Mcb, Db, Ceiling Fan, Ac, Geyser And Allied Works At Nepalipatti And 764 Asc Bn Under Ge ( Af ) Mohanbari
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 04-Jun-2022 | corrigendum | Date | 23-Jun-2022 |
BOQ
| Sl. No. | Item Description |
| 1 | Taking down copper / aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting , casing caping etc., removing materials to store for keeping in safe custody or for taking credit, cutting chasing as required and making good the disturbed surfaces including finishes to match with adjacent surfaces of walls, floors, etc. complete all as specified and as directed. |
| 2 | M&L point wiring with 1.5 sqmm single core, PVC insulated, unsheathed FRLS copper cable, 1100 volts grade, with multi stranded copper conductor drawn through and including PVC casing caping (double lock pattern) medium grade and accessories on wall / ceiling surfaces etc. with and including 1.5 sqmm single core PVC insulated, multistranded, unsheathed,FRLS copper conductor cable as continuous earth continuity conductor (green in colour) with cast Iron / pressed steel terminal boxes 60 mm deep, on walls with 3 mm thick plastic laminated / hylam sheet cover, fixed on wall / other surfaces with brass screws for mounting or housing switches, socket outlets, fan regulators, etc including all other fixing accessories for one light / fan / bell point controlled by one 5 / 6 Amps switch complete all as specified and directed. |
| 3 | All as per Sl. item No. 2 above but for one 5 / 6 Amps socket outlet point on the same board. |
| 4 | All as per Sl. item No. 2 above but for one 5 / 6 Amps socket outlet point on independent board. |
| 5 | M&L point wiring with 2.5 sqmm single core, PVC insulated, unsheathed FRLS copper cable, 1100 volts grade, with multi stranded copper conductor drawn through and including PVC casing caping (double lock pattern) medium grade and accessories on wall / ceiling surfaces etc. with and including 1.5 sqmm single core PVC insulated, multistranded, unsheathed,FRLS copper conductor cable as continuous earth continuity conductor (green in colour) with cast Iron / pressed steel terminal boxes 60 mm deep, on walls with 3 mm thick plastic laminated / hylam sheet cover, fixed on wall / other surfaces with brass screws for 15 / 16 Amps socket outlet on independent board complete all as specified and directed. |
| 6 | M&L point wiring with 4 sqmm single core, PVC insulated, unsheathed FRLS copper cable, 1100 volts grade, with multi stranded copper conductor drawn through and including PVC casing caping (double lock pattern) medium grade and accessories on wall / ceiling surfaces etc. with and including 2.5 sqmm single core PVC insulated, multistranded, unsheathed,FRLS copper conductor cable as continuous earth continuity conductor (green in colour) with cast Iron / pressed steel terminal boxes 60 mm deep, on walls with 3 mm thick plastic laminated / hylam sheet cover, fixed on wall / other surfaces with brass screws for 15/16 Amps socket outlet / power unit on independent board complete all as specified and directed. |
| 7 | M&L point wiring with 1.5 sqmm single core, PVC insulated, unsheathed FRLSH copper cable, 1100 volts grade, with multi stranded copper conductor drawn through and including non-metallic, rigid non mettalic PVC conduit (medium grade) wall / ceilingwith and including 1.5 sqmm single core PVC insulated, multistranded, unsheathed, FRLS copper conductor cable as continuous earth continuity conductor (green in colour) with cast Iron / pressed steel terminal boxes 60 mm deep, on walls with 3 mm thick plastic laminated / hylam sheet cover, fixed on wall / other surfaces with brass screws for mounting or housing switches, socket outlets, fan regulators, etc. including all other fixing accessories for one light / fan / exhaust fan / call bell point controlled by one 5 / 6 Amps switch and making good the disturbed surfaces including finishes to match with adjacent surfaces complete all as specified and directed. |
| 8 | All as per Sl. item No. 7 above but for one 5 / 6 Amps socket outlet point on same board. |
| 9 | All as per Sl. item No. 7 above but for one 5 / 6 Amps socket outlet point on independent board. |
| 10 | M&L point wiring with 2.5 sqmm single core, PVC insulated, unsheathed FRLS copper cable, 1100 volts grade, with multi stranded copper conductor drawn through and including non-metallic, rigid non mettalic PVC conduit (medium grade) wall / ceilingwith and including 1.5 sqmm single core PVC insulated, multistranded, unsheathed, FRLS copper conductor cable as continuous earth continuity conductor (green in colour) with cast Iron / pressed steel terminal boxes 60 mm deep, on walls with 3 mm thick plastic laminated / hylam sheet cover, fixed on wall / other surfaces with brass screws for 15 / 16 Amps socket outlet on independent board and making good the disturbed surfaces including finishes to match with adjacent surfaces complete all as specified and directed. |
| 11 | M&L point wiring with 1.5 sqmm single core, PVC insulated, unsheathed FRLS copper cable, 1100 volts grade, with multi stranded copper conductor drawn through and including ERW conduit (medium grade) wall / ceilingwith and including 1.5 sqmm single core PVC insulated, multistranded, unsheathed, FRLS copper conductor cable as continuous earth continuity conductor (green in colour) including all other fixing accessories for one light / fan / exhaust fan / call bell point controlled by one 5 / 6 Amps switch and making good the disturbed surfaces including finishes to match with adjacent surfaces complete all as specified and directed. |
| 12 | S&Fswitch pianoflush typeone way, 5 / 6 Amps, 230 voltcomplete all as specified and directed. |
| 13 | S&F bell push piano flush type one way, 5/6 Amp,230 V complete all as specified and directed. |
| 14 | S&F socket outlet piano flush type 5 pin 5 / 6 Amps, 230 voltscomplete all as specified and directed. |
| 15 | S&F switch socket combination5 pin, 5 / 6 Amp, piano flush type complete all as specified and directed. |
| 16 | S&F switch socket combination2 in 1,6 Pin, 15/16 Amp, piano flush type universal complete all as specified and directed. |
| 17 | Supply and fixing ceiling rose (ISI marked) surface bakelite 65 mm x 50 mmthree/ two terminal suitable for 230 Volts AC 6 Amps complete all as specified and directed by Engineer-in-charge. |
| 18 | S&F stepped type electronic fan regulator, piano flush typewith 5 step, AC 50 Hz 230 Volts grade complete all as specified and directed. |
| 19 | S&F call bell, ding dong,AC 230 V, single pole complete all as specified and directed. |
| 20 | S&F in repair lamp holder, PVC/Polycarbonate type with cord grip cap suitable for batten fittings including taking down complete all as specified and as directed.Make :- Havells / Anchor / Legrand |
| 21 | M & L for sub main wiring with 2 runs of 4.0 sqmm main wire alongwith 1 run of 4.0 sqmm earth wire (green in colour) single core FRLS PVC insulated, unsheathed, multi-stranded, 1100 volts grade copper conductor cable, drawn through and including adequate size PVCcasing caping (double lock pattern) medium grade with all fittings & accessories on walls / ceiling surfaces etc., complete all as specified and directed.NOTE :- Two runs of main copper conductor, one run of earth wire and one run of PVC casing caping shall be measured as one unit length. |
| 22 | All as per item No. 21 above but with 2 runs of 6 sqmm main wire along with 1 run of 6 sqmm earth wire. |
| 23 | All as per item No. 21 above but with 4 runs of 6 sqmm main wire along with 1 run of 6 sqmm earth wire. |
| 24 | Supply and fixed in repairs Rigid non-metallic PVC conduit , 25mm dia inclusive of all tees, bends, elbows, reducers, terminal boxes bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc complete all as specified and directed by Engineer-in-charge. |
| 25 | Supply and fixed in repair bulk head luminaire 10 Watt LED, surface mounted with opal diffuser,Ingress protection IP-65 with fixture,complete all as specified and directed by Engineer-in-charge. Make CROMPTON GREAVES cat part no. LBHP-10-CDL or equivalent ofPHILIPS/GE |
| 26 | Supply and fixed in repair recessed mounted round 6 watts LED downlight (round/square type) , aesthetically designed aluminium die-cast enclousers, with seperate replaceable constant current driverfor grid ceiling,including necessary connection complete all as specified and directed by Engineer-in-charge. Make CROMPTON GREAVES cat part no. LSCRM-6W/LSCSM-6W or equivalent ofPHILIPS/GE. |
| 27 | Supply and fixed in repair recessed mounted LED luminaire 15 watts for grid ceiling, square fixture with opal diffuserSlim, compact, aluminium die cast edge lit panel, and separate electronic driver complete all as specified and directed by Engineer-in-charge.Make CROMPTON GREAVES cat part no. LSCSM-15W or equivalent ofPHILIPS/GE |
| 28 | Supply and fixed in repair recessed mounted LED luminaire 36 watts for grid ceiling,square fixturewith opal diffuser Slim, compact, aluminum die cast edge lit panel, and separate electronic driver complete all as specified and directed by Engineer-in-charge.Make CROMPTON GREAVES cat part no. LCTLRNE-36-FO-CDL or equivalent ofPHILIPS/GE |
| 29 | Supply and fixed in repair wall mounted LED batten 18/20 watts Decorative ultra slim square profile LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient ready to use pack complete all as specified and directed by Engineer-in-charge. Make Crompton Greaves Catpart no LDL-20-CDL or eqivalent in Philips/GE. |
| 30 | Supply and fixed in repair wall mounted LED batten 10 watts decorative ultra slim square profile LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient ready to use pack. Complete all as specified and directed by Engineer-in-charge.Make-Crompton Cat part no. LDL-10-CDL or equivalent in philips/GE. |
| 31 | Supply and fixed in repair CIMFR certified LED 1x20 watt flameproof batten suitable for single 16W/20W. Recommended for gas/vapor group of IIA & IIB and zone 1 & 2. IP-65 protected including connection wire complete all as specified and directed by Engineer-in-charge.Make CROMPTON GREAVES cat part no. EXTN1LT8-16/20 or equivalent ofBAJAJ/SUDHIR |
| 32 | Taking down and refixing after complete repairing of the ceiling fan of any make/model/sweep in its original position, connecting and testing, including provision of cable from ceiling rose/connector to fan complete all as specified and as directed. (Note :- Bearing / gun metal bush / rubber bush & bolts / capacitor / rewinding / shaft etc. will be measured and paid separately) |
| 33 | M&L for rewinding of ceiling fans 1200 /1400 mm sweep of any make/model, including removal of existing burnt windings completely and carefully from the slots, cleaning the slots thoroughly with necessary cleaning agent, applying slot insulation and rewinding with super enameled copper wire of existing guage complete including dismantling and re-assembling of starter, rotor, blades etc. all as specified and as directed by the engineer-in-charge. Note:- (Rate is inclusive of transportation to and from MES store/site to workshop in Tinsukia/ Dibrugarh) |
| 34 | M&L for cleaning/preparation of surfaces of ceiling fans up to 1200 mm sweep thoroughly and painting with one coat of spray painting (body and blades both) using synthetic enamel white paint over the existing paint including filling ofcavities with filler and stenciling of MES No. with black paint over it complete all as specified and as directed by the engineer-in-charge.(Note:- Rate is inclusive of filling of cavities with filler and matching to existing finishing of fans) |
| 35 | Supply and fixing in repairs of ball bearings, bearing No.6201 suitable for ceiling fans/wall mounted fans /exhaust fans /air circulator fans /table fans of any make/model/sweep complete all as specified and as directed. |
| 36 | Supply and fixing in repairs oil type capacitor of 2.5 Mfd suitable for ceiling fan / wall mounted fan /exhaust fan /air circulator fan /table fan complete all as specified and as directed. |
| 37 | Dismantling of existing unserviceable heating element from geyser and S&F new heating element of 2.0kw 230 volt suitable for 50 ltrs geyser including testing and connecting all as specified and as directed. |
| 38 | Dismantling of existing unserviceable heating element from geyser and S&F new heating element of 1.5kw 230 volt suitable for 25-35 ltrs geyser including testing and connecting all as specified and as directed. |
| 39 | Dismantling of existing unserviceable thermostat of geyser 50/25 ltr capacity and S&F new thermostat matching with existing geyser including all connection and testing complete all as specified and as directed. |
| 40 | S&F in repairs three pin plug top 15 Amps 230 volt, 50Hz complete with all connection etc all as specified and directed. |
| 41 | S&F in repairs PVC connections 15 mm size of length 600 mm heavy duty with 2 Nos brass CP union complete all as specified and directed. |
| 42 | S&F in repairs MCB SP 10 to 32 Amp, 10 kA, 230V\"C\" curve complete all as specified and as directed. |
| 43 | S&F in repairs MCB SPN 16 to 32 Amp, 10 kA, 240V\"C\" curve complete all as specified and as directed. |
| 44 | S&F in repairs MCB SPN 40 to 63 Amp, 10 kA, 240V\"C\" curve complete all as specified and as directed. |
| 45 | S&F in repairs MCCB 3 pole 100 Amps breaking capacity 16 KA, 415 volts fixed type complete all as specified and directed. |
| 46 | S&F in repairs MCCB 3 pole 125 Amps breaking capacity 16 KA, 415 volts fixed type complete all as specified and directed. |
| 47 | Supply and fixed in repairs connection and testing AC Plug and socket DB, 20Amp, 230 volts, 50Hz with one No.MCB SP 230 Volts, \"C\" series, breaking capacity 10 KA of rating 20 Amps complete all as specified and directed |
| 48 | S&F in repair MCB DB, SPN 4 way,230 volts, 50Hz, IP-43, IK 09, double door type with metal door, with 100A copper neutral and earth bus bar for fixing MCB, fixing flush to wall & making good the disturbed surfaces complete all as specified and as directed. |
| 49 | S&F in repair MCB DB, SPN 8 way, 230 volts, 50Hz IP-43, IK 09, double door type with metal door, with 100A copper neutral and earth bus bar for fixing MCB, fixing flush to wall & making good the disturbed surfaces complete all as specified and as directed. |
| 50 | S&F in repair MCB DB, SPN 12 way, 230 volts, 50Hz, IP-43, IK 09, double door type with metal door, with 100A copper neutral and earth bus bar for fixing MCB, fixing flush to wall & making good the disturbed surfaces complete all as specified and as directed. |
| 51 | S&F in repair MCB DB, TPN 4 way,415 volts, 50Hz, IP-43, IK 09, double door type with metal door, with 100A copper neutral and earth bus bar for fixing MCB, fixing flush to wall & making good the disturbed surfaces complete all as specified and as directed. |
| 52 | Supply and fixed in repair flame proof Switch socket & plug combined in LM6 cable termination box in LM6, 16 Amp, 230 Volts, 50Hz, 2P + earth complete all as specified and directed by Engineer-in-charge. |
| 53 | Supply and fixed in repair switch flame proof, rotary type with terminal box in LM6, 16 Amp, 230 Volts, 50Hz, single pole complete all as specified and directed by Engineer-in-charge. |
| 54 | Material and labour laying well burnt old sizebricks, straight or curved on plan , laid flat with width equal to length of brick , laid dry over electric cable for protection all as specified. |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender