| 1 | Supplying and fixing of following sizes of Heavy Duty PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 2 | 25 mm |
| 3 | 20 mm |
| 4 | Supplying and fixing of 8 Module power box with screw less decorative plate modular having 1 No. tinny trip and 3 Nos. socket 6 pin 15/16 and and 1 No. indication lamp and making connection etc. as required. |
| 5 | S/F3 module power box with screw lass decorative plate modular having 1 nos Switch 15/16 amp and 1 nos socket 6 pin 15/16 making connection etc as reqd. |
| 6 | S/F 6 module power box with screw less decorative plate modular having 2 nos. switch 15/16 amps and 2 Nos. socket 6 pin 15/16 making connection etc. as required. |
| 7 | S/F 12 module power box with screw less decorative plate modular having 4 nos. switch 15/16 amps and 4 Nos. socket 6 pin 15/16 making connection etc. as required. |
| 8 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 9 | 5/6 amps switch |
| 10 | 3 pin 5/6 amps socket outlet |
| 11 | S/F/testing & commissioing of prewired LED double box type fiting (1x20 watts) complete with all accessories and one 20 watts tube (stellar bright) of 2100 lumen, 6500k etc. on the existing surface/ down road i/c connection with 1.5 sqmm FRLS PVC copper cond. cable in suitable size PVC sleeve etc. as required. (TMC 501 P1 x T- LED 20W P3241) (Philips Make) |
| 12 | S/F/testing & commissioning of prewired LED double box type fitting (2x20 watts) complete with all accessories and two 20 watts tube (stellar bright) of 2100 lumen, 6500k etc. on the existing surface/ down road i/c connection with 1.5 sqmm FR LS PVC copper cond. cable in suitable size PVC sleeve etc. as required (TMC 501 P 2x T- LED 20W P3241) (Philips make) |
| 13 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed Heavy duty class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. `Group C |
| 14 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 15 | 1x 1.5 sq,mm |
| 16 | 2 x 2.5 sq.mm |
| 17 | 2x4 sq.mm |
| 18 | 2 x 6 sqmm |
| 19 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed Heavy Duty PVC conduit as required4cx16 sqmm + 2cx16 sqmm earth wire |
| 20 | Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required.Group B |
| 21 | P/F installation , testing and commissioning of 100 amps MCCB 35 KA L.M. Series 3 Pole 415 volts AC supply complete with connection in the suitable enclosure etc. as required. |
| 22 | 100 amps MCCB 35 KA (L M Series) |
| 23 | 200 amps MCCB 35 KA (L M Series) |
| 24 | Supplying and fixing of fan rod of size 10 foot length for the ceiling fan etc. as required at site. |
| 25 | Supplying and fixing 48\" ceiling fan with all accessories including making connection etc. as required (Crompton) |
| 26 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required) 12 WAY (4 + 36) double door |
| 27 | 12 WAY (4 + 36) double door |
| 28 | 8 WAY (4 + 24) double door |
| 29 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole |
| 30 | Supplying and fixing following 100 amps four pole 415 Volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required |
| 31 | S/I/T/C of 15\" ( 380 mm)Heavy Duty Exhaust fan 900 RPM with suitable size louver shutter and making connection i/c wooden work if required. |
| 32 | S/F the following size / Module G.I. box along with modular base and cover plate and modular switches in recess etc. as required. |
| 33 | 18 Modules |
| 34 | 12 Modules |
| 35 | Providing and fixing of LED 18/20 watt stellar bright 2100 lumens tube including making connection etc. as required at site. (Philips) |
| 36 | S/F DLP UPVC trunking compartmentwith cover clip on separates partition left right topinternalangle, flat angle, raise function,flat function cover to body joints mosaic clip & support from mosaicisolation bracket 2 mm thick plastic.(Legrand/Hagger) 105 mm x 50 mm with all accessories. |
| 37 | Supplying and fixing Tinny Trip AC box complete with all accessories with plug and top on surface/ recessed and making the good the same ec. as required at site. and 1 Nos. of 25 amps G series SP MCB connection etc. as required at site. |
| 38 | Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required.1 run of cable |
| 39 | Supplying and fixing stepped type fan regulator on the existing modular plate switch box including connections but excluding modular plate etc as reqd. |