Annual Maintenance Contract For Electrical Works At Various Lis Of Mid Anantnag- 1 Mechanical Transportation, Loading, Unloading And Stacking Of Various Items / Machinery Equipment Using Appropriate Means Of Transport As Under: 2 Private Car, Auto-Rickshaw Or Similar With 1.0 Km Lead 3 Extra Per Kilometer For Lead >1.0 Kms Upto 5.0 Kms 4 Extra Per Kilometer For Lead >5.0 Kms Upto 10.0 Kms 5 Extra Per Kilometer For Lead >10.0 Kms Upto 20.0 Kms 6 Extra Per Kilometer For Lead >20.0 Kms Upto 30.0 Kms 7 Extra Per Kilometer For Lead >30.0 Kms Upto 50 Km 8 Load Carrier Auto, Mini Van Or Similar With 1.0 Km Lead 9 Extra Per Kilometer For Lead >1.0 Kms Upto 5.0 Kms 10 Extra Per Kilometer For Lead >5.0 Kms Upto 10.0 Kms 11 Extra Per Kilometer For Lead >10.0 Kms Upto 20.0 Kms 12 Extra Per Kilometer For Lead >20.0 Kms Upto 30.0 Kms 13 Extra Per Kilometer For Lead >30.0 Kms Upto 50 Km 14 Mini Truck Like Tata Mobile, Bolero Camper Or Similar With 1.0 Km Lead 15 Extra Per Kilometer For Lead >1.0 Kms Upto 5.0 Kms 16 Extra Per Kilometer For Lead >5.0 Kms Upto 10.0 Kms 17 Extra Per Kilometer For Lead >10.0 Kms Upto 20.0 Kms 18 Extra Per Kilometer For Lead >20.0 Kms Upto 30.0 Kms 19 Extra Per Kilometer For Lead >30.0 Kms Upto 50 Km 20 Truck, Tipper Or Similar With 1.0 Km Lead 21 Extra Per Kilometer For Lead >1.0 Kms Upto 5.0 Kms 22 Extra Per Kilometer For Lead >5.0 Kms Upto 10.0 Kms 23 Extra Per Kilometer For Lead >10.0 Kms Upto 20.0 Kms 24 Extra Per Kilometer For Lead >20.0 Kms Upto 30.0 Kms 25 Extra Per Kilometer For Lead >30.0 Kms Upto 50 Km 26 Hiring Of Mobile Crane Up To 5 Ton Capacity 27 Hiring Of Hydraulic Back Hoe Loader. 28 Motors 29 Dismantling And Assembling 30 Disconnecting Of All Motor Leads, Dismantling Of Motor, Draining Off The M.Oil ( If Applicable ) And Collection In Suitable Pan, Carefully Taking Out The Rotor From The Stator, And Completely Disassembly As Per Requirement Of Job: 31 Up To 10 Hp 32 >10 Hp –60 Hp 33 >60 Hp – 200 Hp 34 > 200 Hp -350 Hp 35 > 350 Hp 36 Complete Assembling Of All Motor Parts, Refilling Of Drained Out M. Oil ( If Applicable ) , Coupling And Alignment With Pump, Reconnecting Of Leads And Testing On Full Load. 37 Up To 10 Hp 38 >10 Hp –60 Hp 39 >60 Hp – 200 Hp 40 > 200 Hp -350 Hp 41 > 350 Hp 42 Repairs To Non Reverse Ratchet On Driving End ( De ) Of Vertical Electric Motor By Way Of: Disconnecting All Leads From Motor And Marking The Terminals, Uncoupling And Dismounting Of Motor From The Motor Stool. Removal Of Non-Reverse Ratchet Plate / Seal Plate / Ratchet Pins, Etc As Per Requirement And Refitting After Necessary Repairs / Replacements. Refitting Of Motor, Coupling And Alignment With The Pump. The Job Includes Testing Of Motor On Load. 43 Replacement Of Non Reverse Ratchet On Non Driving End ( Nde ) Of Vertical Electric Motor By Way Of: Isolating The Motor, Dismantling Of Top End Cover Of The Motor, Removing Of Non-Reverse Ratchet Plate / Seal Plate / Ratchet Pins, Etc As Per Requirement And Refitting Back Of Parts After Necessary Repairs / Replacements And Testing Of Motor On Load. 44 Replacement Of Driving End ( De ) Bearing Of Vertical Electric Motor By Way Of: Disconnecting All Leads From Motor And Marking The Terminals, Uncoupling Of Motor From The Pump, Dismounting Of Motor From The Motor Stool. Opening The Bottom End Cover Of De Bearing Housing. Carefully Extracting The Old Damaged Bearing From The Housing With The Help Of Bearing Puller, Etc And Fitting Of New Bearing In Its Place. Refitting Back Of Motor Parts, Coupling And Alignment With The Pump. The Job Excludes The Cost Of Bearing 45 Up To 60 Hp 46 >60 Hp – 200 Hp 47 > 200 Hp -350 Hp 48 > 350 Hp 49 Replacement Of Non Driving End ( Nde ) Bearing Of Vertical Electric Motor By Way Of: Disconnecting All Leads From Motor And Marking Of Terminals, Dismantling Of Top End Cover Of The Motor & Removal Of Nonreverse Ratchet Assembly. Draining Off The M.Oil And Collection In A Suitable Pan ( If Applicable ) , Extraction Of Old Damaged Bearing From The Motor, Fitting Of New Nde Bearing And Refilling Of Old M.Oil. The Job Includes Load Testing Of Motor. 50 Up To 60 Hp 51 >60 Hp – 200 Hp 52 > 200 Hp -350 Hp 53 > 350 Hp 54 Replacement Of Driving End ( De ) Bearing Of Horizontal Electric Motor By Way Of: Disconnecting All Leads From Motor And Marking The Terminals, Uncoupling Of Motor From The Pump. Opening The End Cover Of De Bearing Housing. Carefully Extracting The Old Damaged Bearing From The Housing With The Help Of Bearing Puller, Etc And Fitting Of New Bearing In Its Place. Refitting Back Of Motor Parts, Coupling And Alignment With The Pump. The Job Includes Testing Of Motor On Load. 55 Up To 60 Hp 56 >60 Hp – 200 Hp 57 > 200 Hp -350 Hp 58 > 350 Hp 59 Replacement Of Connection Plate To Motor After Dismantling Of Damaged One 60 Up To 60 Hp 61 >60 Hp – 200 Hp 62 > 200 Hp -350 Hp 63 > 350 Hp 64 Complete Rewinding Of Submersiblemotors Of Different Ratings In Pvc Insulated Copper Wire Of Proper Pitch, Grade, Gauge And Number Of Turns As Per Sample After Complete Removal Of Burnt Out Winding, Cleaning Of Slots, Etc.. The Job Includes All The Charges On Account Of , Sleeves, Bamboo Sticks And Skilled Labour ( Rewinding Charges ) , Testing Of Motor On Full Load At Site. 65 Bearings For Motors 66 Providing Of New Bearing As Under: ( Prefered Makes: Skf Or Equivalent Imported Make ) . 67 3210 Bearing 68 3212 Bearing 69 3213 Bearing 70 3309 Bearing 71 3313 Bearing 72 51310 Bearing 73 51312 Bearing 74 51314 Bearing 75 51320 Bearing 76 6014 Bearing 77 6028 Bearing 78 6217 Bearing 79 6220 Bearing 80 6305 Bearing 81 6306Bearing 82 6307Bearing 83 6308Bearing 84 6309 Bearing 85 6310Bearing 86 6311 Bearing 87 6312 Bearing 88 6313 Bearing 89 6314Bearing 90 6315 Bearing 91 6316 Bearing 92 6318 Bearing 93 6320 Bearing 94 6322 Bearing 95 6406 Bearing 96 6408 Bearing 97 6410 Bearing 98 6411Bearing 99 6412 Bearing 100 6415 Bearing 101 6418 Bearing 102 6320Bearing 103 7220 Bearing 104 7312 Bearing 105 7318Bearing 106 N317bearing 107 Nu316 Bearing 108 Nu318 Bearing 109 Nu322 Bearing 110 Nu324 Bearing 111 29322Bearing 112 29324Bearing 113 29328 Bearing 114 29330 Bearing 115 29424Bearing 116 29426Bearing 117 Voltage Stabilizers 118 Dismantling Of 415V 3-Ph Voltage Stabilizer By Way Of Opening Of Top Lid, Disassembling Of Voltage Regulator, Removing Of All Incoming And Outgoing Connections, Taking Out Of Damaged Copper Legs After Removal Of Core, Etc. The Job Includes Draining Out Of T. Oil And Its Safe Placement For Further Refilling. 119 Up To 50 Kva 120 >50 Kva - 100 Kva 121 >100 Kva – 250 Kva 122 >250 Kva – 400 Kva 123 >400 Kva 124 Assembling Of All Parts Of 3-Phase Voltage Stabilizer, Connecting Of Leads Of All Incoming And Outgoing Connections And Refilling Of Old Drained Out Of T. Oil 125 Up To 50 Kva 126 >50 Kva - 100 Kva 127 >100 Kva – 250 Kva 128 >250 Kva – 400 Kva 129 >400 Kva 130 Rewinding Of Burnt / Damaged Windings Of Different Rating Voltage Stabilizer, Horizontal, Vertical Motors , Auto Transformer Starters , Coil Assembly Using Superior Quality Wire Of Proper Gauge As Per Requirement With Superior Insulation. The Job Includes All The Charges On Account Of, Tapping, Sleeves, Varnishing, And Skilled Labour ( Rewinding Charges ) , Testing Of Stabilizer On Full Load At Site. 131 Copper Wire 132 Copper Strip 133 Aluminium Wire 134 Aluminium Strip 135 Replacement Of Copper Contact Point On Regulator Plate Complete Job 136 Providing And Complete Replacement Of Tap Changer Rotary Switch / Regulator ( Double Plate ) Of Voltage Stabilizer Of Nominal Size: 137 9 Sq. Inch 138 12 Sq. Inch 139 16 Sq. Inch 140 18 Sq. Inch 141 Providing And Fitting Of Brass Bush Rod Complete With Nuts And Washers As Under: 142 12Mm 143 26Mm 144 29Mm 145 25Mm 146 Consumables 147 Providing Of Fresh Transformer Oil Conforming To Is 335 ( Preferred Make: Indian Oil Servo / Hpcl ) 148 Providing Of Used And Filtered Transformer Oil For Lv Electrical Appliances 149 Providing Of Ap3 Grease ( All Purpose Type ) ( Preferred Makes: Hpcl / Indian Oil / Bpcl / Castrol / Caltex ) 150 Starters 151 Providing, Installation, Testing And Commissioning Of Dry Type 10Hp ( L&T / Bentex / Kilburn Make ) . Dol Starters, Mechanically Operated, Working On 50Hz, 450±10% Ac Voltage Supply For Operation Of Priming Units. The Starter Shall Be Mounted With Nuts And Bolts For Proper Fixing On Pannel. 152 Repairs To Upto 200 Hp Oisd Starter By Way Of Complete Dismantling Of The Starter & Then Replacement Of; And Then Testing On Full Load 153 Replacement Of Long / Fixed Contact Point As Per Sample 154 Replacement Of Short / Movable Contact Point As Per Sample 155 Replacement Of Damaged Trip Coil Contact Point As Per Sample 156 Replacement Of Copper Bush Rod As Per Sample 157 Setting Right Of Handle Mechanism & Retaping / Thimbling Of The Terminal Connections 158 Rewinding Burnt / Damaged Limb / S Of Autotransformer Coil Assembly ( Comprising Of Three Limbs ) Of All Rating Atsusing Superior Quality Copper Wire Of Proper Gauge As Per Requirement With Superior Insulation, Varnish, Etc. ( Note: The Unserviceable Scrap Copper Generated Shall Be Property Of The Firm And Is Taken Into Account For Estimation Of Rates ) . 159 Contactors 160 Providing And Fitting Of 3-Pole Contactor With Specified Coil Voltage: 161 Ml – 1.5 162 Ml – 2 163 Ml – 3 164 Ml – 4 165 Ml – 6 166 Ml – 10 167 Ml – 12 168 Mnx 50 169 Mnx 70 170 Mnx 80 171 Mnx 95 172 Mnx 110 173 Mnx 140 174 Mnx 185 175 Mnx 225 176 Mnx 250 177 Mnx 325 178 Mnx 400 179 Mnx 550 180 Mnx 650 181 Schneider Electric Lc1f265 ( Without Coil ) 182 Schneider Electric Lc1f330 ( Without Coil ) 183 Schneider Electric Lc1f400 ( Without Coil ) 184 Schneider Electric Lc1f630 ( Without Coil ) 185 32A Ac-3 Rating ( Siemens 3Tf / L&T Type Mo / Schneider ) 186 45A Ac-3 Rating With 2No + 2Nc Auxillary Contacts ( Siemens 3Tf / L&T Type Mo / Schneider ) 187 Providing And Fitting Of New Contact Kit Set For Contactors 188 9A To 45A Ac-3 Rating ( Siemens 3Tf / Equivalent ) 189 L&T Ml 2 / 3 190 L&T Ml 4 / 6 191 L&T Ml 10 / 12 192 L&T Mnx 50 / 70 / 80 193 L&T Mnx 95 / 110 / 140 194 L&T Mnx 185 / 225 / 250 195 L&T Mnx 300 / 400 196 L&T Mnx 550 / 650 197 Schneider Electric Lc1f185 / Lc1f225 198 Schneider Electric Lc1f265 / Lc1f330 199 Schneider Electric Lc1f400 200 Schneider Electric Lc1f630 201 Providing And Fitting Of New Contact Kit Set For Contactors 202 32A Ac-3 Rating ( Siemens 3Tf / Equivalent ) 203 L&T Ml 2 204 L&T Ml 3 205 L&T Ml 4 206 L&T Ml 6 207 L&T Ml 10 208 L&T Ml 12 209 Providing And Fitting Of Auxillary / Control Relay ( L&T Mx0 Or Similar ) For Accontrol 210 Providing And Fitting Of Auxillary / Control Relay ( L&T Mn0 Or Similar ) For Dccontrol 211 Providing And Fitting Of ( 1No+1Nc ) Side Mounting Auxillary Contact Block ( For L&T / Schneider Electric Make Contactors ) . 212 Providing And Fitting Of Front Mounting Auxillary Contact Block Having 04 Contacts ( All Combinations ) ( For L&T / Schneider Electric / Siemens Make Contactors ) 213 Timing Relays 214 Providing, Fitting And Setting Of Electropneumatic Timing Relay With Timing Range Upto 60S; Coil Voltage 415V Ac ( Bch Or Equivalent Make ) . 215 ( 2No + 2Nc ) Double Block; On Delay 216 ( 2No + 2Nc ) Double Block; On & Off Delay 217 Providing And Fitting Of Spares For Electropneumatic Timing Relay ( Bch Make Orequivalent ) 218 ( 2No + 2Nc ) Contact Block 219 Magnetic Coil 415V Ac 220 Magnet Frame Assembly Without Coil 221 Providing, Fitting And Setting Of Din Mounted Electronic Timer ( L&T Or Equivalent Make ) 222 Star Delta ( Range From 3S - 120S ) 240V Ac 223 Star Delta ( Range From 3S - 30S ) 240 - 415V Ac 224 On Delay ( 0.3S - 30Hrs ) 240V Ac 225 Providing, Fitting And Setting Up Of Single Range Auto Reset Synchronous On Delay Timer ( L&T Or Equivalent Make ) 226 Thermal Overload Relay 227 Providing, Fitting And Setting Of Thermal Overload Relay Of Specified Relay Range ( Make: L&T Mn2 ) 228 Relay Range In Between 0.2A To 15A 229 14-23A 230 20-33A 231 24-40A 232 Providing, Fitting And Setting Of Thermal Overload Relay Of Specified Relay Range ( Make: L&T Mn5 ) 233 30-50A 234 36-60A 235 45-75A 236 66-110A 237 Providing, Fitting And Setting Of Thermal Overload Relay Of Specified Relay Range ( Make: L&T Ml1 ) 238 Relay Range In Between 0.15A To 16A 239 Providing, Fitting And Setting Of Thermal Overload Relay Of Specified Relay Range ( Make: L&T Ml2 / 3 ) 240 Relay Ranges In Between 9A To 42A 241 Switchgear 242 Mccb 243 Providing And Fitting Of 3-Pole 415V Mccb With Thermal Magnetic Release Having 36 Ka Breaking Capacity ( Ics= 100% Icu ) ( Make: L&T / Schneider Or Equivalent ) Having Max. Of Thermal Release Range As Under: 244 100A 245 125A 246 160A 247 200A 248 250A 249 320A 250 400A 251 500 A 252 630A 253 800A 254 Providing And Fitting Of 3-Pole 415V Mccb With Thermal Magnetic Release Having 50 Ka Breaking Capacity ( Ics= 100% Icu ) ( Make: L&T / Schneider Or Equivalent ) Having Max. Of Thermal Release Range As Under: 255 125A 256 160A 257 200A 258 250A 259 320A 260 400A 261 500 A 262 630A 263 800A 264 Providing And Fitting Of 4-Pole 415V Mccb With Adjustable Thermal And Fixed Magnetic Setting Having 36Ka Breaking Capacity Ics = 100% Icu ( Make: L&T D-Sine Or Equivalent ) Having Max. Of Thermal Release Range As Under: 265 160A 266 200A 267 250A 268 320A 269 400A 270 500 A 271 630A 272 800A 273 Providing And Fitting Of 4-Pole 415V Mccb With Adjustable Thermal And Fixed Magnetic Setting Having 50Ka Breaking Capacity Ics = 100% Icu ( Make: L&T D-Sine Or Equivalent ) Having Max. Of Thermal Release Range As Under: 274 160A 275 200A 276 250A 277 320A 278 400A 279 500 A 280 630A 281 800A 282 Spares For Acb ( L&T C-Power ) 283 Providing And Fitting Of Pole Assembly For Draw Out Type Acb ( L&T C-Power ) 284 Upto 1250A 285 2000A 286 Providing And Fitting Of Arc Chute ( 440V ) For Acb ( L&T C-Power ) 287 Upto 1250A 288 1600 - 2000A 289 Providing And Fitting Of Jaw Contact For Acb ( L&T C-Power ) 290 630-1000A 291 1250A 292 1600A / 2000A 293 Providing And Fitting Of Fixed Arcing Contact For Acb ( L&T C-Power ) 294 800- 1600A 295 2000A 296 Providing And Fitting Of Moving Arcing Contact For Acb ( L&T C-Power ) 297 800- 2000A 298 Providing And Fitting Of Shunt Release For Acb ( L&T C-Power ) 299 Providing And Fitting Of Under Voltage Release For Acb ( L&T C-Power ) 300 Providing And Fitting Of Earth Fault Release For Acb ( L&T C-Power ) 301 Providing And Fitting Of Terminal Adaptor For Draw Out L&T C-Power Acb Of Ratings As Under: 302 Upto 800 - 1250A 303 1600 - 2000A 304 Providing And Fitting Of Thermal-Magnetic Release ( Type Dn1 ) For L&T C-Power Acb 305 Providing And Fitting Of Ct For Dn1 Type L&T C-Power Acb 306 800 / 1000A 307 1250 / 1600A 308 2000A 309 Providing And Fitting Of Main Spring For 3-Pole Acb ( L&T C-Power ) 310 800- 1600A 311 2000A 312 Providing Of Racking Handle For Draw-Out Type Acbs ( L&T C-Power ) Rating Upto 2000A 313 Providing And Replacement Of Spring Charging Motor ( Ac / Dc ) 314 Providing And Replacement Of Motor Limit Switch 315 Providing And Fitting Of 96X96 Flush Mounting 3-Phase Led Ammeter / Voltmeter Of Class 1 Accuracy ( Make: L&T / Schneider / Rishabh / Ae ) 316 Providing And Fitting Of Flush Type Analog Moving Iron Ac Meter As Under: ( Make: Rishabh / Ae / C&S / Bch ) 317 48X48mm 500V Voltmeter 318 96X96mm 500V Voltmeter 319 144X144mm 500V Voltmeter 320 Volt-Ammeter 500V, Current Ranges Upto 125A ( Ae / Rishabh / L&T ) 321 96X96mm Ammeter ( 5A Ct Operated ) 322 Providing And Fitting Of Flush Type Frequency Meter With Range 45-55Hz: ( Make: Rishabh / Ae / L&T / Schneider / Bch ) 323 Providing And Fitting Of 10A Line Current Ammeter Selector Switch With Off ( Make: L&T / Rishabh / Ae / Teknic ) 324 Providing And Fitting Of 10A Voltmeter Selector Switch With Off ( Make: L&T / Rishabh / Ae / Teknic ) 325 Providing And Fitting Of Tape Insulated Ring Type Metering Current Transformers ( Ae / Rishabh / Crompton / Kilburn ) As Under: 326 100 / 5A Or 150 / 5A - Class 1 - Burden 5Va 327 200 / 5A - Class 1 - Burden 10Va 328 400 / 5A - Class 1 - Burden 15Va 329 600 / 5A - Class 1 - Burden 15Va 330 800 / 5A - Class 1 - Burden 15Va 331 1000 / 5A - Class 1 - Burden 15Va 332 2000 / 5A - Class 1 - Burden 15Va 333 Extra For 1A Secondary Upto 600 / 1A Over Corresponding Rate 334 Providing And Fitting Of Analog Vac Hour Meter ( Make: L&T Or Equivalent Make ) 335 Din Mounting Type 336 Flush Mounting Type 337 Providing And Fitting Of Flush Or Projecting Head Push Button With Contact Block ( L&T / Teknic / Abb / Bch / Schneider Or Any Other Reputed Make ) 338 Providing And Fitting Of Led Phase Indicator With Surge Protection ( L&T / Teknic / Abb / Bch / Schneider Or Any Other Reputed Make ) 339 Providing And Fitting 3 Phase, 3 / 4 Wire Adjustable Under & Over Voltage Monitoring Relay ( Minilec Vct D2 Or Equivalent ) 340 Providing, Fitting And Setting Of 415V Auto Reset Single Phase Preventor ( L&T / Minilec / Bch Or Equivalent Make ) 341 50V Or Less Unbalance & 1 C / O Din Mounted 342 50V Or Less Unbalance & 1 C / O Panel Wall Mounted 343 70V Or Less Unbalance & 2 C / O Din Mounted 344 Providing And Fitting Of 32A Dp Switch ( Anchor / Ssk Or Any Other Reputed Make ) 345 Providing Of Hrc Fuses ( 2A - 32A ) Ratings 346 Providing And Fitting Of Fuse Holders For Fuses Upto 32A Rating 347 Providing And Fixing Upvc Panel Trunking With Cover 348 15X15mm 349 25X25mm 350 Providing And Fitting Of Terminal Block 100A - 3 Way 351 Terminals / Lugs / Thimbles 352 Providing And Fitting Of Various Aluminium Lugs / Thimbles ( Dowells / Action / Or Equivalent Make ) With Tapping, Insulation As Under: 353 16 Sq. Mm 354 25 Sq. Mm 355 35 Sq. Mm 356 50 Sq. Mm 357 70 Sq. Mm 358 95 Sq. Mm 359 120 Sq. Mm 360 150 Sq Mm 361 185 Sq. Mm 362 240 Sq. Mm 363 300 Sq. Mm 364 400 Sq. Mm 365 500 Sq Mm 366 630 Sq. Mm 367 800 Sq. Mm 368 Providing And Fitting Of Various Copper Lugs / Thimbles ( Dowells / Action / Or Equivalent Make ) With Tapping, Insulation As Under: 369 16 Sq. Mm 370 25 Sq. Mm 371 35 Sq. Mm 372 50 Sq. Mm 373 70 Sq. Mm 374 95 Sq. Mm 375 120 Sq. Mm 376 150 Sq Mm 377 185 Sq. Mm 378 240 Sq. Mm 379 300 Sq. Mm 380 400 Sq. Mm 381 630 Sq. Mm 382 800 Sq. Mm 383 Wires And Cables 384 Providing And Fitting Of Pvc Insulated 1100V Single Core Industrial Copper Cable As Under 385 16 Sqmm 386 25 Sqmm 387 35 Sqmm 388 50 Sqmm 389 70 Sqmm 390 95 Sqmm 391 120 Sqmm 392 150 Sqmm 393 185 Sqmm 394 240 Sqmm 395 300 Sqmm 396 400 Sqmm 397 Providing And Fitting Of Pvc Insulated 1100V Single Core Industrial Un Armored Aluminium Cable As Under 398 16 Sqmm 399 25 Sqmm 400 35 Sqmm 401 50 Sqmm 402 70 Sqmm 403 95 Sqmm 404 120 Sqmm 405 150 Sqmm 406 185 Sqmm 407 240 Sqmm 408 300 Sqmm 409 400 Sqmm 410 500 Sqmm 411 630 Sqmm 412 800 Sqmm 413 1000 Sqmm 414 Providing And Fitting Of Xlpe 1100V 3.5-Core Industrial Armored Aluminum Cable As Under 415 25 Sqmm 416 35 Sqmm 417 50 Sqmm 418 70 Sqmm 419 95 Sqmm 420 120 Sqmm 421 150 Sqmm 422 185 Sqmm 423 240 Sqmm 424 300 Sqmm 425 400 Sqmm 426 500 Sqmm 427 630 Sqmm 428 Providing And Fitting Of Pvc Insulated 1100V Flat 3-Core Industrial Copper Cable For Submersible Pump Motors As Under 429 6 Sqmm 430 10 Sqmm 431 16 Sqmm 432 25 Sqmm 433 35 Sqmm 434 Providing And Fitting Of Pvc Insulated 1100V Copper Cable For Electrification: Finolex / L&T / Havells / Kei ) 435 1 Sqmm 436 1.5 Sqmm 437 2.5 Sqmm 438 4 Sqmm 439 6 Sqmm 440 2 X 10 Sq Mm Aluminium Unarmored 441 2 X 16 Sq Mm Aluminium Unarmored 442 2 X 16 Sq Mm Aluminium Armored 443 Providing And Laying Of Acsr Conductor On Poles 444 .03 Acsr 445 .05 Acsr 446 Providing And Fitting Of Single Core 11 Kv Armored Aluminium Cable 447 25 Sq Mm 448 35 Sq Mm 449 50 Sq Mm 450 70 Sq Mm 451 Providing And Fitting Of 3 Core 11 Kv Armored Aluminum Cable 452 25 Sq Mm 453 35 Sq Mm 454 50 Sq Mm 455 70 Sq Mm 456 11Kv Ht Cables 457 35 Sq Mm Abc 458 50 Sq Mm Abc 459 70 Sq Mm Abc 460 35 Sq Mm 3 - Core 461 50 Sq Mm 3 - Core 462 70 Sq Mm 3 - Core 463 Lighting 464 Lighting Points In 1.0 Sq Mm Multi Strand Pvc Insulated Copper Conductor To Be Laid / Carried In Pvc Channel / Conduit. The Job Incl. P / F Of 5 / 6 Amp. Switch, Angle / Button Holder, 9 - 12 W Led Lampwith Necessary Fixtures 465 Lighting Points, Bulk Head Type In 1.0 Sq Mm Multi Strand Pvc Insulated Copper Conductor To Be Laid / Carried In Pvc Channel / Conduit. The Job Incl. P / F Of 5 / 6 Amp. Switch, Angle / Button Holder, 9 -12 W Led Lampwith Necessary Fixtures 466 Heating Points In 2.5 Sq Mm Multi Strand Pvc Insulated Copper Conductor To Be Laid / Carried In Pvc Channel / Conduit. The Job Incl. P / F Of 16 Amp.Ss Combine 467 5-Pin Socket Points In 1.5 Sq Mm Multi Strandpvc Insulated Copper Conductor To Be Laid / Carried In Pvc Channel / Conduit 468 Indicator Pointsin 1.0 Sq Mm Multi Strandpvc Insulated Copper Conductor To Be Laid / Carried In Pvc Channel / Conduit 469 Ceiling Fan Make C / W Regulator Switch, Ceiling Rose, Wiring In 1.5 Sq Mm Multi Strand Pvc Insulated Copper Conductor To Be Laid / Carried In Pvc Channel / Conduit. And Necessary Fixtures 470 Providing And Installation Of Spn Sheet Steel Enclosed Distribution Boxes - Single Door 471 4 Way 472 8 Way 473 12 Way 474 16 Way 475 Providing And Installation Of ‘B’ Series Mcb 240V, 50Hz, 10Ka Suitable For Lighting And Other Domestic Loads 476 6-32A Sp 477 40 A – Sp 478 6-32A Dp 479 40 A – Dp 480 63 A – Dp 481 Providing And Installation Of ‘B’ Series Mcb 240V, 50Hz, 10Ka Suitable For Lighting And Other Domestic Loads 482 Providing And Installation Of Busbar Chamber Tpn 483 Hd Copper 484 Ec Grade Aluminium 485 Providing, Installation And Testing Of Floodlight Led 5000 / 6000 / 6500K Ip65 486 30 W 487 48 W 488 50 W 489 100 W 490 120 W 491 Manpower 492 Hiring Charges Of Electrician ( For Troubleshooting / Revamping Of Existing Electrical Fitting, Etc. Exclusive Of Specified Works ) : 493 Hiring Charges Of Labourer For Support Of Electrician 494 Portable Light 495 3 W Led Rechargeable Torch 496 Led Lantern With Twin Charging Mode – Charging Cable And Solar Panel ( Inclusive Of Panel ) 497 Conduit 498 Providing And Fixing 25Mm Pvc Round Conduit ( Medium ) With Allied Pvc Fittings 499 Providing And Fixing Polypropylene Corrugated Flexible Conduit 500 25 Mm 501 32 Mm 502 Providing And Fitting Of 50 Mm Dia Flexible Canvas Sleeve / Conduit 503 Providing And Fitting Of 50 Mm Dia Flexible Rubber Sleeve / Conduit 504 Providing / Laying Of 3Mm Thick High Density Anti Skid Rubber Floor Mating On The Machine Floor Level Area 505 Erection Of Metallic Pole Of Following Length In Cement Concrete 1:3:6 ( 1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 40 Mm Nominal Size ) Foundation Including Excavation And Refilling Shuttering Etc. As Required. 506 Above 4.5 Meter And Up To 6.5 Meter 507 Above 6.5 Meter And Up To 8.0 Meter 508 Above 8.0 Meter And Up To 10.0 Meter 509 Above 10.0 Meter And Up To 12.0 Meter 510 Rebate On Account Of Old Parts 511 Extracted, Damaged Copper Wire ( During Rewinding Of Electric Gadgets ) 512 Extracted, Damaged Aluminium Wire ( During Rewinding Of Electric Gadgets ) 513 Contact Points / Brass Bush Rods 514 Copper Bus Bars 515 Aluminium Bus Bars