Military Engineer Services-MES has published Cwe / Pat / T-75 / 2021-22 Provn Of Med Store For Echs And Ration Shelter For Mh Under Ge North Patiala Provn Of Med Store For Echs And Ration Shelter For Mh Schedule ASection-I (Building Works) 2 Total amount of Sch A Sec I (Building Works) 3 Sc. Submission Date for this Tender is 27-06-2022. Machine Tools Tenders in patiala Punjab. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 20-Jun-2022 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 23-06-2022 |
2 | 23-Jun-2022 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 27-06-2022 |
Sl. No. | Item Description |
1 | Schedule "A"Section-I (Building Works) |
2 | Total amount of Sch "A" Sec I (Building Works) |
3 | Schedule "A"Section-II (EXCAVATION AND EARTH WORKS) |
4 | Total amount of Sch "A" Sec II (Excavation and Earth Works) |
5 | Schedule "A"Section-III (INTERNAL ELECTRIC SUPPLY) |
6 | Total amount of Sch "A" Sec III (Internal Electric Supply Works) |
7 | Schedule "A"Section-VI (Road and Path Works) |
8 | Total amount of Sch "A" Sec IV (Road and Path Works) |
9 | Schedule "A"Section-V (Ext Elect Suppy) |
10 | Total amount of Sch "A" Sec V (Ext Elect Works) |
11 | Schedule "A"Section-VI(Misc Items of Works) Note :This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col. 5 siginifies this fact only. |
12 | Supply & fix1 x 20 W, 4 feet 230 Voltsnecessary electric connection with twisted flexible PVC copper counductor cablefrom ceiling rose complete all as specified and directed by Engineer in Charge.Make : Cat Part No LHLDDCXCML8Q020 of Havells or equivalent in makes as per Appendix "B". |
13 | Supply & fix security LED light fitting20 watt luminaries new generation energy saving ,with lens made of pressure die cast alluminium alloy powder coatedhousing LM24inclsnecessary electric connection with twisted flexible PVC copper counductor cable clamp for fixingcomplete all as specified and directed by Engineer in Charge.Make : Cat Part No LHEXAYP7PN6K020 of Havells or equivalent in makes as per Appendix "B". |
14 | Supply and fixMCB SPN 40Amp ,10KA 240volts ISI marked all as specified and directed by Engr in charge. |
15 | Supply and fixMCB SP 06-32 Amps ,10KA 240volts ISI marked all as specified and directed by Engr in charge. |
16 | Earthingcomplete with galvanised steel plate earth electrode 60cmx60cmx6mm thick, burried directly in ground (earth pit not less than 2.25 mtrs deep below ground level) with top edge of earth plate not less than 1.5 Mtr below normal ground level connected to galvanised earth lead wire 4.0mm dia by means of bolt, nut check nuts and washer of galvanised iron or steel with protection of GI, medium grade 15mm bore upto adequate length watering pipe 25/40mm bore for protection of GI wire/strip from earth electrode to and incl the supplying and laying charcoal dustcommon salt, PCC 1:3:6 type CI (using 20mm gradedcrushed stone aggegrate) as in chamber and MS angle iron frame 40x40x3mm and RCC cover 40mm thick 1:2:4 type B1 (using 20mm gradedcrushed stone aggregate) reinforced with 8mm dia, TMT bars @75mm c/c both ways with MS handle 12mm dia, PGI funnel and wire mesh, 20 mmdia GI pipe light grade for watering all as shown in electrical plate No 3 of SSR Part-I of 2009 and connected to earth test point testing complete all as specified and directed |
17 | Machine pressed rubber moulded ISI marked precast cement concrete interlocking paver block any shape and size with grey cement and no pigment confirming to IS-15658-2006 of 60mm thickness M-35 Grade and including filling of interstices with fine sand over including 25mm thick layer of sand chusion complete all as specified. |
18 | S &F ceiling rose bakelite,63.5mm 3 terminals with base plate ISI marked, complete allas specified and directed by Engineer in Charge. |
19 | S&Fceiling fan complete with blades,down rod, electronic regulator and accessories 230V,1200mm, complete all as specified and as directed. |
20 | Sandcushioningwith clean dry sandto cables with layer of sand 8cm before laying of cable and 15cm thick after laying of cablecomplete all as specified. Note : For payment purpose punned thickness of 18cm shall be measured against spread thickness of 23cm as mentioned in para 19.75 of SSR part-I. |
21 | MCB DB double door 240 volts with 200 Amps standard bus bar of suitable size and common neutral link all enclosed in standard sheet flush mounting type, drilling holes for incoming and out going cables complete suitable for 8 ways with IP43 protection complete all as specefied and as directed. |
22 | Supply and hanging exhaust fan with sweep 350mm single phase 250v AC supply heavy duty including all fixing material and arrangements, provision of 2 way PVC connector, copper bunched flexible cable 1 Sqmm twin twisted PVC insulated cable from ceiling rose / connector to fan complete all as specified and as directed. |