Madhya Pradesh Power Transmission Company Limited has published Construction Of Second Circuiting Of 132Kv Dcss Damoh220-Patera Line With Acsr Panther Equivalent Htls Conductor For Power Supplyto Greenfield Cement Plant Project At Village-Harduwaken, Dist.-Panna Of M / S Jaykaycem ( Central ) Ltd. From 132Kv. Submission Date for this Tender is 14-07-2022. Cement plant Tenders in Jabalpur Madhya Pradesh. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 13-Jun-2022 | Date Extension Notice | Date | 29-06-2022 |
2 | 29-Jun-2022 | Date Extension Notice 2 | Date | 14-07-2022 |
Sl. No. | Item Description |
1 | Supply of Fabricated, Galvanised tower members (Shortages) as per drawings of towersMS Steel |
2 | G.I. Bolts/Nuts and washers etc. |
3 | ACSRPanther |
4 | ACSRPanther equivalent HTLS Conductor |
5 | Long RodPolymer Insulator SinglesuspensionstringforACSRPanther Conductor (equivalent to 9 disc of 70kN) |
6 | Long RodPolymer Insulator Single tension string forACSR Panther Conductor (equivalent to 10 disc of 90kN) |
7 | 70 kN EMS Disc Insulators |
8 | Post Insulators for 132kV |
9 | Double Susp. Hardware with AGS Assembly for Panther |
10 | Double Tension Hardware for ACSR Panther |
11 | Double Susp. Hardware with AGS Assembly for Panther equivalent HTLS Conductor |
12 | Single tension Hardware for ACSR Panther equivalent HTLS Conductor |
13 | Double Tension Hardware for ACSR Panther equivalent HTLS Conductor |
14 | Pilot String (Single Suspension) for ACSR Panther |
15 | Midspan joints for ACSR Panther |
16 | Repair Sleeve for ACSR Panther |
17 | Midspan joints for ACSR Panther equivalent HTLS Conductor |
18 | Vibration dampers for ACSR Panther equivalent HTLS Conductor |
19 | Repair Sleeve for ACSR Panther equivalent HTLS Conductor |
20 | P. I. Clamp for ACSR Panther Conductor equivalent HTLS Conductor |
21 | T Clamp for ACSR Panther Conductor equivalent HTLS Conductor Run-ACSR Panther Conductor equivalent HTLS Conductor Tap |
22 | Pad Clamp for ACSR Panther Conductor equivalent HTLS Conductor |
23 | Enamelled Phase Plates (set of 3 No.-each R/Y/B) |
24 | Earthing set (2setsperGantry Column) |
25 | Monkey/Bird Guard (Set of 03) |
26 | Bird"s Excreta Preventer on Suspension & Pilot Insulator Strings |
27 | Check survey (required for verification of shortages on towers & ground clearences, tree counting, TFR measurement etc.) |
28 | Excavation forWet soil |
29 | Excavation forSoft rock |
30 | Excavation forHard rock |
31 | Tower Foundation Earthing of Gantry Colomns in two legs |
32 | Concreting including back filling, muffing, copping & curing etc. Concrete Ratio 1:2:4 (M15) |
33 | Concreting including back filling, muffing, copping & curing etc. Concrete Ratio 1:3:6 (M10) |
34 | Cost of laying reinforcement steel including cost of materials |
35 | Tower erection (incl. tightening & punching) and Welding: |
36 | Stringing : One Ckt. of the Double circuit line with Panther equivalent HTLS Condtr. with other ckt. live |
37 | Fixing of Phase plate only (in case of 2nd circuit stringing) |
38 | Protection of Tower footings Excavation (for tower site leveling and revetment work). Dry soil |
39 | Protection of Tower footings Excavation (for tower site leveling and revetment work).Wet soil |
40 | Protection of Tower footings Excavation (for tower site leveling and revetment work). Soft rock |
41 | Cost of concrete 1:3:6 mix required for base padding including all material including cement. |
42 | Cost of building revetment with stones with 1:5 cement mortar per Cum of stone masonry including pointing by Ration 1:3 |
43 | Cost of top seal cover of revetment wall with 1:2:4 mix concrete. |
44 | Back filling and levelling of the volume enclosed by revetment walls in Cum. |
45 | Providing and fixing 100mm dia A.C. pipe for weep holes (Average length of per pipe 1.0 Meter) |
46 | Counter Poice Earthing: Erection of counterpoise earthing including all material, excavation and back filling. |
47 | Counter Poice Earthing: Cost of providing additional earthing at the each counterpoise wire incl.cost of material. |
48 | De-stringing & Re-stringing: One circuit of D/C or M/C lineon ACSR Panther with at least circuit live |
49 | Dismantling: One circuit of D/C or M/C line with at least one circuit live |
50 | Transportation of dismantled material |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail