Supply Erection Installation And Commissioning Of Material Equipment For The Work Of Release Of Ag Connection In Fy 2022-23 On Turnkey Basis In Respect Of Dausa Lot-I Circle Under The Domain Of Jaipur Discom Against Supply of material (All material shall , jaipur-Rajasthan

Jaipur Vidyut Vitran Nigam Limited-JVVNL has published Supply Erection Installation And Commissioning Of Material Equipment For The Work Of Release Of Ag Connection In Fy 2022-23 On Turnkey Basis In Respect Of Dausa Lot-I Circle Under The Domain Of Jaipur Discom Against Supply of material (All material shall . Submission Date for this Tender is 16-06-2022. Crushers Breakers and Grinders Tenders in jaipur Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

32465995
Corrigendum : Supply Erection Installation And Commissioning Of Material Equipment For The Work Of Release Of Ag Connection In Fy 2022-23 On Turnkey Basis In Respect Of Dausa Lot-I Circle Under The Domain Of Jaipur Discom Against Supply of material (All material shall
Open Tender
Indian
Rajasthan
jaipur
16-06-2022

Tender Details

Supply Erection Installation And Commissioning Of Material Equipment For The Work Of Release Of Ag Connection In Fy 2022-23 On Turnkey Basis In Respect Of Dausa Lot-I Circle Under The Domain Of Jaipur Discom Against Supply of material (All material shall be supplied as per specification enclosed with the bidding documents):- 2 9 Mtr. LONG PCC POLES OF 200 KG WORKING LOAD WITH FACTOR OF SAFTY 2.5. 3 33 KV S/C LATTICE STRUCTURE (36 UNGALVANISED WITH 1 NOS 33 KV CROSS ARM(CHANNEL) WITH REQUIRED NUTS AND BOLTS. 4 11/0.433 KV, 40 KVA ALUMINIUM WOUND BIS LEVEL-2 COMPLETELY SELF PROTECTED (CSP) DISTRIBUTION TRANSFORMERS WITH PROVISIO OF LT BUSHING BOX 5 25 KVA, 11/0.433 KV, ALUMINIUM WOUNDBIS LEVEL-2 (STAR-1) COMPLETELY SELF PROTECTED (CSP) DISTRIBUTION TRANSFORMERS WITH PROVISION OF LT BUSHING BOX. 6 16 KVA, 11/0.433 KV, ALUMINIUM WOUNDBIS LEVEL-2 (STAR-1) COMPLETELY SELF PROTECTED (CSP) DISTRIBUTION TRANSFORMERS WITH PROVISION OF LT BUSHING BOX. 7 GALVANISED STEEL STAY SET 16x1800 MM 8 11 KV STAY INSULATOR 9 GALVANISED STEEL STAY WIRE 7/10 SWG 10 STAY SET CLAMPS SUITABLE FOR 9 MTR. LONG PCC POLES 11 H/W FOR DISC INSULATORS 45KN T&C TYPE 12 DISC INSULATORS 45KN T&C TYPE 13 M.S. NUTS & BOLTS (ASSORTED SIZE) 14 ACSR RABBIT CONDUCTOR 15 11 KV V CROSS ARM WITH TOP HAMPER AND CLAMPS ( ANGLE) 16 GALVANIZED M.S. FROGED 11 KV PIN 17 11 KV PIN INSULATOR 18 11/0.4 KV S/S STRUCTURE SET FOR 3-PH 40/25/ 16 KVA TRANSFORMER ON DOUBLE POLE 19 HORN GAP FUSE SET WITH POST INSULATOR 11 KV 20 MS ROD TYPE EARTHING SET WITH WIRE & CLAMP with following details(1 No.- Galvanised M.S. Rod 20 mm dia electrodes having3 Meter length, 2 Nos.- Galvanised Earthing clamp of M.S.Flat of size 50x6 mm 220 mm length. One welded with earthelectrode and loose to be bolted; 2 Nos.- Galvanised Bolts, Nuts and Spring washers and G.I.Wire Size 8 SWG of 15 Meter length) 21 1.4 MTR CHANNEL 100x50x6 MM BRACKET WITH CLAMP 22 4C X 16 SQ. MM. LT PVC INSULATED PVC SHEATHED CABLE (ARMOURED) 23 M.S. ANGLES 75 X 75 X 6 MM (FOR GUARDING) 24 THREE PHASE FOUR WIRE WHOLE CURRENT METER OF RATING 10-60 A HAVING BACKLIT LCD DISPLAY WITH METER BOX (FREE ISSUE). 25 M.S. CHANNEL 75 X 40 X 6 MM (FOR EXTENSION BRACKET) 26 LT SHUNT CAPACOTORS 3 KVAR 27 LT SHUNT CAPACOTORS 6 KVAR 28 DANGER PLATE 29 11 KV LINE DP SET 30 P.G. CLAMPS FOR RABBIT 31 G.S. EARTH WIRE 8 SWG 32 Erection of material:- 33 Trimming of tree branches/plants and preparing route approchases for proposed line. 34 Excavation of pit in Hard soil to erect various supports and stay sets including stacking of excavated muck from the edge of excavation/pit. 35 (A) Height of poles/R.S.Joist/M.S. Rail /Size of pit 36 9 Mtr/ 1.2mx0.6mx1.50 m deep 37 (B) Lattice Tower /Size of pit 38 11.4/10.8 Mtr/ 1.5mx1.5m x1.80 m deep 39 (C)Stay set/Depth of pit 40 6x5/8-0.75x0.5x1.35m 41 Excavation of pit in ordinary rock which does not require blasting to erect various supports and stay sets including stacking of excavated muck from the edge of excavation/pit. 42 (A) Height of poles/R.S.Joist/M.S. Rail /Size of pit 43 9 Mtr/ 1.2mx0.6mx1.50 m deep 44 (B) Lattice Tower /Size of pit 45 11.4/10.8 Mtr/ 1.5mx1.5m x1.80 m deep 46 (C)Stay set/Depth of pit 47 6x5/8-0.75x0.5x1.35m 48 Safe carriage of PCC poles including loading / un-loading 49 c) 9 Mtr.long 200 Kg. PCC pole 50 within10 Kms.- 51 Above 10 Km. & upto 30 Km. add foreach Km. or part thereof 52 Above 30 Km. add for each Km. or part thereof (50 KM) 53 Safe carriage of steel( fabricated and unfabricated) I.e.M.S. Rails, R.S.Joists, M.S.Channels, M.S.Angles, M.S.Flat, G.I.Stay Sets, G.I. Stay Wire, G.I.Wire Nut & Bolts etc. and ACSR Conductor including loading and unloading and stacking in Nigam store /at work site 54 Within10 Kms. 55 Above 10 Kms. & upto 30 Kms. Add for each Km.or part thereof. 56 Above 30 Kms. Add for each Kms. or partthereof. (50 KM) 57 Safe Carriage of insulator, hardware, cable etc.including loading/unloading and stacking in Nigam.stores etc. 58 Within10 Kms. 59 Above 10 Kms. & upto 30 Kms. Add for each Km.or part thereof. 60 Above 30 Kms. Add for each Kms.or part thereof. (50 KM) 61 Safe carriage of fabricated lattice towers structures and sub-station structures type AB, AB beams, isolators structures etc. including loading/unloading and stacking in the Nigam. Stores / at work site. 62 Within10 Kms. 63 Above 10 Kms. & upto 30 Kms. Add for each Km.or part thereof. 64 Above 30 Kms. Add for each Kms.or part thereof.(50 KM) 65 Safe Carriage of 11/.4 KV 3 Phase distribution transformer including loading/unloading and stacking in Nigam.stores etc. 66 10 &16 kva 67 Within10 Kms. 68 Above 10 Kms. & upto 30 Kms. Add for each Km.or part thereof. 69 Above 30 Kms. Add for each Kms.or part thereof. (50 KM) 70 25 & 40 kva 71 Within10 Kms. 72 Above 10 Kms. & upto 30 Kms. Add for each Km.or part thereof. 73 Above 30 Kms. Add for each Kms.or part thereof. (50 KM) 74 Erection of all type of steel supports in the excavated pit in alignment after checking the same with plumb line including fixing of cross arms and top hamper before erecting the supports. The support should be grouted and muffed in cement concrete of ratio 1:3:6 as per item No. 5.6 the remaining portion of the pit will be back filled with soil. The nuts & bolts will be provided by the contractor as per Nigams specification for which payment will be made at the prevailing store issue rates. The cost muffing and grouting will be paid extra. 75 Lattice Structure 76 Erection of PCC poles in excavated pit with fixing of brackets,cross arms & top hampers as required in alignment after checking the same with plumb line. The support is to be back filled with soil with proper ramming. The nuts & bolts are to be provided by the contractor as per Nigams specification for which the payment will be made at the prevailing Discom store issue rates. 77 IN RURAL AREA 78 PCC Poles 9 Mtr. Long(200Kg.) 79 Erection & assembly of 2 pole structures ofof steel supports or of PCC poles in excavated pit in alignment afterchecking the same with plumb line. Including fixing of top bracing of m.s. channels with pilot plates and clamps. The support is to be back filled with soil with proper ramming. The nuts & bolts are to be provided by the contractoras per Nigams specfication for which the payment will be made at the prevailing Discom store issue rates. 80 PCC Poles 9 Mtr. Long(200Kg.) 81 Erection & fixing of G.I.Stay sets with anchor plates in excavated pit in required position and back filling with soil with proper ramming.The work includes fixing of stay clamps. Stay insulator with stay wire at both ends with proper tension.Size of stay set/stay wire 82 6x5/8 with 7/10 SWG stay wire 83 Providing and laying of cement concrete in ratio 1:3:6 using 43 grade cement,river sand and 12 mm to 20 mm graded blast crusher broken in pit/foundation according to the size/type of supports/stay set including compaction/curing for 21days in steel plates shuttering /farmer base.(1.2X1.2 x2.1 M)/Tower 84 Fixing of all type of fabricated material on erected supports with nut & bolts as per approved design & drawing of sub-station. 85 Fixing of guarding Bracket arms with clamp on erected support as per design. The nuts &bolts will be supplied by the contractor as per Nigams specification for which payment will be made as per prevailing Discom store issue rates. 86 11 KV line 87 Fixing of earth wire clamp on erected supportas per design. The nuts &bolts will be supplied by the contractor as per Nigams specification for which payment will be made as per prevailing Discom store issue rates. 88 Fixing and assembly of disc.point channel pair with pilot plates&clamps on erected double pole structure as per design. The nuts &bolts are to be provided by the contractor as per Nigams specification for which payment will be made as perprevailing Discom store issue rates. 89 11 KV line 90 Fixing and assembly of disc. Point channel pair with pilot plates & clamps on erected Single pole structure as per design. The nuts & Bolts are to be Provided by the contractor as per Nigams specification for which payment will be made as per prevailingDiscom store issue rates. 91 11 KV Line 92 Fixing of 11kv B&S/T&C type disc insulator of 11kv lines(each unit consiting of 1nos.disc.& 1set of H/ W ) on terminal point including fixing of hardware and strips. 93 Fixing of 11 KV pininsulator with pins. 94 ssembly and installation of Horn Gap fuse set (set of 3 Nos)on erected structure as per design, complete in all respectwith post insulator includingjumperingonbothendsforconnection with the system. The nuts & bolts will be supplied by the contractorfor which payment will be made as per prevailing Discom store issue rates. 95 11kv Horn Gap fuse set. 96 Installation testing as per Nigams norm & commissioning of11/0.4 kv distribution transformer on erected supports including fixing of base channels as per requirement jumpering on HV&LV side, crimping of lugs/clamping earth connections of body and neutral of transformer with wire/strip (as already provided with earthing) complete in all respect. The PG clamps nuts & Bolts will be supplied by the contractor for which payment will be made as per prevailing Discom store issue rates. 97 10 & 16 KVA 98 25 & 40 KVA 99 Fixing of danger plates on supports/structure 100 Fixing of PG clamp of Weasel /Rabbit Conductor 101 Laying, Jointing , Stringingtensioning and clamping of conductor with proper sag as directed, using bolted type hardware including binding on pin insulators, jumpering on section points with binding wire/P.G. clamps Aluminium jointing sleeves will be used for jointing the conductor. The line must stand at proper voltage on charging. The contractor will be provide P.G. clamps for which payment will be made as per prevailing Discom store issue rates. 102 ACSR RABBIT 103 Laying, jointing,stringing,tensioning and clamping of G.I.Earthwire continuosly on single/double pole by using earth clamps /nuts & bolts with washers and earth reel etc.including proper binding at each end.The nuts and bolts will be supplied by thecontractor for which payment will be made as per prevailing Discom store issue rates. 104 (B) IN RURAL AREA 105 G.I.Earth wire 8 SWG 106 Drawing & strining of G.I 4 wire over the guarding brackets for guarding of road crossing /P&T crossing/railway track crossing (for one span only)with cross G.I wire laces at an intraval of two meter each or required as per location using EYE bolt Nuts. 107 8 SWG with laces of 10 SWG 108 Earthing of line for all type of supports as per REC construction standards using Stay wire/GI wire with one pcs of M.S. rod 20mm dia each 3 meter long and driving into earth by mechanical means MS rod, MS flat & stay wire will be supplied by the contractor. Ifmaterial is supplied by the contractor the payment will be made as per prevailing Discom store issue rates.(in case of PCC Poles earthing mustbe connected with earthwire already available on PCC Pole at bottom) 109 Earthing of 11/0.4 KV distribution transformer /sub-station with 3 pieces of M.S. Rod 20 mm dia each 3 meter long and drivingthem in to earth by mechanical means at a distance as per approved design & drawing & specification. The work includes flattening of top ends of M.S. Rod drilling a hole of 9/16 dia. At Flattened top and tightening of M.S. flat 50x6mm (having 3 hole 2ends and 1mm middle) with nuts and bolts with m.s. rod. Top end hole. The flat will also be welded with M.S. rod. The end will be connected to equipments as under as under in sequence. 110 Fixing of three phase meter cummeter box(complete unit)at the premises of existing/new consumerswith 4 Nos Anchor fastners with rust proof size M-6x50 mm on the wall as per the positionof holes already provided on the meter box. The meter box must be housed perfectly vertical/plumb line,anchor fasteners are to be supplied/provided by the contractor including safe carriage from S/D store to consumers site and depositing removed meter and meter box if any in S/D store). 111 IN RURAL AREA 112 Laying of 1100 volt heavy duty armoured XLPE cable of aluminum coudctor of following size conforming to IS: 7098 (Pt-I) (latest amended) overhead service line from pole to meter terminals for release of new LT connections/replacement of damaged/obsolete service line (except agriculture one). The cable must be fixed on wall with clamps /hooks properly at a interval of one meter. 113 4 Core 16/25 sq. mm 114 fixing of 3 phase LT shunt capacitor (3/6/9/12KVAR) near starterof motor for agriculature consumers to be fixed with MS clamp of -shape of size 2x10mm having two nos.holes for fixing of LT capacitors besides starter of consumer with the help of two no.machine screw. The starter shall be connected using PVC sheathed single core of 4 sq.mm AI. cable conforming to relevant IS. The wire shall be cut in three pieces which shall be used for extending existing wire whith making proper joint and joint shall be taped with MS compoundPVC tape roll. The ends of wire shall be properly crimped with lugsthimble etc.All material shall be supplied by the contractor except LT shunt capacitor (The LT shunt capacitor shall be supplied by Nigam)

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 08-Jun-2022 Amendment in the last bid submission date and bid opening date and in PQR/ bidding documents of TN-523. Date 16-06-2022
2 08-Jun-2022 Amendment in the last bid submission date and bid opening date and in PQR/ bidding documents of TN-523. Technical Bid 16-06-2022

Key Value

Document Fees
INR 5 /-
EMD
INR 9022758.0 /-
Tender Value
INR 45.11 Crore /-

BOQ Items

Name of Work: Supply, erection, installation and commissioning of material/ equipment for the work of release of Agriculture connection in FY 2022-23 on turnkey basis in respect of various Circle under the domain of Jaipur Discomagainst TN–523, Dausa, Lot-I (Approximate 2019 Nos. Agriculture connection).
Sl. No. Item Description
1Supply of material (All material shall be supplied as per specification enclosed with the bidding documents):-
29 Mtr. LONG PCC POLES OF 200 KG WORKING LOAD WITH FACTOR OF SAFTY 2.5.
333 KV S/C LATTICE STRUCTURE (36" UNGALVANISED WITH 1 NOS 33 KV CROSS ARM(CHANNEL) WITH REQUIRED NUTS AND BOLTS.
411/0.433 KV, 40 KVA ALUMINIUM WOUND BIS LEVEL-2 COMPLETELY SELF PROTECTED (CSP) DISTRIBUTION TRANSFORMERS WITH PROVISIO OF LT BUSHING BOX
525 KVA, 11/0.433 KV, ALUMINIUM WOUNDBIS LEVEL-2 (STAR-1) COMPLETELY SELF PROTECTED (CSP) DISTRIBUTION TRANSFORMERS WITH PROVISION OF LT BUSHING BOX.
616 KVA, 11/0.433 KV, ALUMINIUM WOUNDBIS LEVEL-2 (STAR-1) COMPLETELY SELF PROTECTED (CSP) DISTRIBUTION TRANSFORMERS WITH PROVISION OF LT BUSHING BOX.
7GALVANISED STEEL STAY SET 16x1800 MM
811 KV STAY INSULATOR
9GALVANISED STEEL STAY WIRE 7/10 SWG
10STAY SET CLAMPS SUITABLE FOR 9 MTR. LONG PCC POLES
11H/W FOR DISC INSULATORS 45KN T&C TYPE
12DISC INSULATORS 45KN T&C TYPE
13M.S. NUTS & BOLTS (ASSORTED SIZE)
14ACSR RABBIT CONDUCTOR
1511 KV "V" CROSS ARM WITH TOP HAMPER AND CLAMPS ( ANGLE)
16GALVANIZED M.S. FROGED 11 KV PIN
1711 KV PIN INSULATOR
1811/0.4 KV S/S STRUCTURE SET FOR 3-PH 40/25/ 16 KVA TRANSFORMER ON DOUBLE POLE
19HORN GAP FUSE SET WITH POST INSULATOR 11 KV
20MS ROD TYPE EARTHING SET WITH WIRE & CLAMP with following details (1 No.- Galvanised M.S. Rod 20 mm dia electrodes having 3 Meter length, 2 Nos.- Galvanised Earthing clamp of M.S.Flat of size 50x6 mm 220 mm length. One welded with earth electrode and loose to be bolted; 2 Nos.- Galvanised Bolts, Nuts and Spring washers and G.I.Wire Size 8 SWG of 15 Meter length)
211.4 MTR CHANNEL 100x50x6 MM BRACKET WITH CLAMP
224C X 16 SQ. MM. LT PVC INSULATED PVC SHEATHED CABLE (ARMOURED)
23M.S. ANGLES 75 X 75 X 6 MM (FOR GUARDING)
24THREE PHASE FOUR WIRE WHOLE CURRENT METER OF RATING 10-60 A HAVING BACKLIT LCD DISPLAY WITH METER BOX (FREE ISSUE).
25M.S. CHANNEL 75 X 40 X 6 MM (FOR EXTENSION BRACKET)
26LT SHUNT CAPACOTORS 3 KVAR
27LT SHUNT CAPACOTORS 6 KVAR
28DANGER PLATE
2911 KV LINE DP SET
30P.G. CLAMPS FOR RABBIT
31G.S. EARTH WIRE 8 SWG
32Erection of material:-
33Trimming of tree branches/plants and preparing route approchases for proposed line.
34Excavation of pit in Hard soil to erect various supports and stay sets including stacking of excavated muck from the edge of excavation/pit.
35(A) Height of poles/R.S.Joist/M.S. Rail /Size of pit
369 Mtr/ 1.2mx0.6mx1.50 m deep
37(B) Lattice Tower /Size of pit
3811.4/10.8 Mtr/ 1.5mx1.5m x1.80 m deep
39(C)Stay set/Depth of pit
406"x5/8"-0.75x0.5x1.35m
41Excavation of pit in ordinary rock which does not require blasting to erect various supports and stay sets including stacking of excavated muck from the edge of excavation/pit.
42(A) Height of poles/R.S.Joist/M.S. Rail /Size of pit
439 Mtr/ 1.2mx0.6mx1.50 m deep
44(B) Lattice Tower /Size of pit
4511.4/10.8 Mtr/ 1.5mx1.5m x1.80 m deep
46(C)Stay set/Depth of pit
476"x5/8"-0.75x0.5x1.35m
48Safe carriage of PCC poles including loading / un-loading
49c) 9 Mtr.long 200 Kg. PCC pole
50within10 Kms.-
51Above 10 Km. & upto 30 Km. add foreach Km. or part thereof
52Above 30 Km. add for each Km. or part thereof (50 KM)
53Safe carriage of steel( fabricated and unfabricated) I.e.M.S. Rails, R.S.Joists, M.S.Channels, M.S.Angles, M.S.Flat, G.I.Stay Sets, G.I. Stay Wire, G.I.Wire Nut & Bolts etc. and ACSR Conductor including loading and unloading and stacking in Nigam store /at work site
54Within10 Kms.
55Above 10 Kms. & upto 30 Kms. Add for each Km.or part thereof.
56Above 30 Kms. Add for each Kms. or partthereof. (50 KM)
57Safe Carriage of insulator, hardware, cable etc.including loading/unloading and stacking in Nigam.stores etc.
58Within10 Kms.
59Above 10 Kms. & upto 30 Kms. Add for each Km.or part thereof.
60Above 30 Kms. Add for each Kms.or part thereof. (50 KM)
61Safe carriage of fabricated lattice towers structures and sub-station structures type AB, AB beams, isolators structures etc. including loading/unloading and stacking in the Nigam. Stores / at work site.
62Within10 Kms.
63Above 10 Kms. & upto 30 Kms. Add for each Km.or part thereof.
64Above 30 Kms. Add for each Kms.or part thereof.(50 KM)
65Safe Carriage of 11/.4 KV 3 Phase distribution transformer including loading/unloading and stacking in Nigam.stores etc.
6610 &16 kva
67Within10 Kms.
68Above 10 Kms. & upto 30 Kms. Add for each Km.or part thereof.
69Above 30 Kms. Add for each Kms.or part thereof. (50 KM)
7025 & 40 kva
71Within10 Kms.
72Above 10 Kms. & upto 30 Kms. Add for each Km.or part thereof.
73Above 30 Kms. Add for each Kms.or part thereof. (50 KM)
74Erection of all type of steel supports in the excavated pit in alignment after checking the same with plumb line including fixing of cross arms and top hamper before erecting the supports. The support should be grouted and muffed in cement concrete of ratio 1:3:6 as per item No. 5.6 the remaining portion of the pit will be back filled with soil. The nuts & bolts will be provided by the contractor as per Nigam"s specification for which payment will be made at the prevailing store issue rates. The cost muffing and grouting will be paid extra.
75Lattice Structure
76Erection of PCC poles in excavated pit with fixing of brackets,cross arms & top hampers as required in alignment after checking the same with plumb line. The support is to be back filled with soil with proper ramming. The nuts & bolts are to be provided by the contractor as per Nigam"s specification for which the payment will be made at the prevailing Discom store issue rates.
77IN RURAL AREA
78PCC Poles 9 Mtr. Long(200Kg.)
79Erection & assembly of 2 pole structures ofof steel supports or of PCC poles in excavated pit in alignment afterchecking the same with plumb line. Including fixing of top bracing of m.s. channels with pilot plates and clamps. The support is to be back filled with soil with proper ramming. The nuts & bolts are to be provided by the contractoras per Nigams specfication for which the payment will be made at the prevailing Discom store issue rates.
80PCC Poles 9 Mtr. Long(200Kg.)
81Erection & fixing of G.I.Stay sets with anchor plates in excavated pit in required position and back filling with soil with proper ramming.The work includes fixing of stay clamps. Stay insulator with stay wire at both ends with proper tension.Size of stay set/stay wire
826"x5/8" with 7/10 SWG stay wire
83Providing and laying of cement concrete in ratio 1:3:6 using 43 grade cement,river sand and 12 mm to 20 mm graded blast crusher broken in pit/foundation according to the size/type of supports/stay set including compaction/curing for 21days in steel plates shuttering /farmer base.(1.2X1.2 x2.1 M)/Tower
84Fixing of all type of fabricated material on erected supports with nut & bolts as per approved design & drawing of sub-station.
85Fixing of guarding Bracket arms with clamp on erected support as per design. The nuts &bolts will be supplied by the contractor as per Nigams specification for which payment will be made as per prevailing Discom store issue rates.
8611 KV line
87Fixing of earth wire clamp on erected supportas per design. The nuts &bolts will be supplied by the contractor as per Nigams specification for which payment will be made as per prevailing Discom store issue rates.
88Fixing and assembly of disc.point channel pair with pilot plates&clamps on erected double pole structure as per design. The nuts &bolts are to be provided by the contractor as per Nigams specification for which payment will be made as perprevailing Discom store issue rates.
8911 KV line
90Fixing and assembly of disc. Point channel pair with pilot plates & clamps on erected Single pole structure as per design. The nuts & Bolts are to be Provided by the contractor as per Nigams specification for which payment will be made as per prevailingDiscom store issue rates.
9111 KV Line
92Fixing of 11kv B&S/T&C type disc insulator of 11kv lines(each unit consiting of 1nos.disc.& 1set of H/ W ) on terminal point including fixing of hardware and strips.
93Fixing of 11 KV pininsulator with pins.
94ssembly and installation of Horn Gap fuse set (set of 3 Nos)on erected structure as per design, complete in all respectwith post insulator includingjumperingonbothendsforconnection with the system. The nuts & bolts will be supplied by the contractorfor which payment will be made as per prevailing Discom store issue rates.
9511kv Horn Gap fuse set.
96Installation testing as per Nigams norm & commissioning of11/0.4 kv distribution transformer on erected supports including fixing of base channels as per requirement jumpering on HV&LV side, crimping of lugs/clamping earth connections of body and neutral of transformer with wire/strip (as already provided with earthing) complete in all respect. The PG clamps nuts & Bolts will be supplied by the contractor for which payment will be made as per prevailing Discom store issue rates.
9710 & 16 KVA
9825 & 40 KVA
99Fixing of danger plates on supports/structure
100Fixing of PG clamp of Weasel /Rabbit Conductor
101Laying, Jointing , Stringingtensioning and clamping of conductor with proper sag as directed, using bolted type hardware including binding on pin insulators, jumpering on section points with binding wire/P.G. clamps Aluminium jointing sleeves will be used for jointing the conductor. The line must stand at proper voltage on charging. The contractor will be provide P.G. clamps for which payment will be made as per prevailing Discom store issue rates.
102ACSR RABBIT
103Laying, jointing,stringing,tensioning and clamping of G.I.Earthwire continuosly on single/double pole by using earth clamps /nuts & bolts with washers and earth reel etc.including proper binding at each end.The nuts and bolts will be supplied by thecontractor for which payment will be made as per prevailing Discom store issue rates.
104(B) IN RURAL AREA
105G.I.Earth wire 8 SWG
106Drawing & strining of G.I 4 wire over the guarding brackets for guarding of road crossing /P&T crossing/railway track crossing (for one span only)with cross G.I wire laces at an intraval of two meter each or required as per location using EYE bolt Nuts.
1078 SWG with laces of 10 SWG
108Earthing of line for all type of supports as per REC construction standards using Stay wire/GI wire with one pcs of M.S. rod 20mm dia each 3 meter long and driving into earth by mechanical means MS rod, MS flat & stay wire will be supplied by the contractor. Ifmaterial is supplied by the contractor the payment will be made as per prevailing Discom store issue rates.(in case of PCC Poles earthing mustbe connected with earthwire already available on PCC Pole at bottom)
109Earthing of 11/0.4 KV distribution transformer /sub-station with 3 pieces of M.S. Rod 20 mm dia each 3 meter long and drivingthem in to earth by mechanical means at a distance as per approved design & drawing & specification. The work includes flattening of top ends of M.S. Rod drilling a hole of 9/16" dia. At Flattened top and tightening of M.S. flat 50x6mm (having 3 hole 2ends and 1mm middle) with nuts and bolts with m.s. rod. Top end hole. The flat will also be welded with M.S. rod. The end will be connected to equipments as under as under in sequence.
110Fixing of three phase meter cummeter box(complete unit)at the premises of existing/new consumerswith 4 Nos Anchor fastners with rust proof size M-6x50 mm on the wall as per the positionof holes already provided on the meter box. The meter box must be housed perfectly vertical/plumb line,anchor fasteners are to be supplied/provided by the contractor including safe carriage from S/D store to consumers site and depositing removed meter and meter box if any in S/D store).
111IN RURAL AREA
112Laying of 1100 volt heavy duty armoured XLPE cable of aluminum coudctor of following size conforming to IS: 7098 (Pt-I) (latest amended) overhead service line from pole to meter terminals for release of new LT connections/replacement of damaged/obsolete service line (except agriculture one). The cable must be fixed on wall with clamps /hooks properly at a interval of one meter.
1134 Core 16/25 sq. mm
114fixing of 3 phase LT shunt capacitor (3/6/9/12KVAR) near starterof motor for agriculature consumers to be fixed with MS clamp of -shape of size 2x10mm having two nos.holes for fixing of LT capacitors besides starter of consumer with the help of two no.machine screw. The starter shall be connected using PVC sheathed single core of 4 sq.mm AI. cable conforming to relevant IS. The wire shall be cut in three pieces which shall be used for extending existing wire whith making proper joint and joint shall be taped with MS compoundPVC tape roll. The ends of wire shall be properly crimped with lugsthimble etc.All material shall be supplied by the contractor except LT shunt capacitor (The LT shunt capacitor shall be supplied by Nigam)
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail