Modification Of Electrical System Of Newly Renovated Djb Lab Including Office Complex And Other Allied Works At Kondli Stp
Tender Value
Ref. Documents
Estimated cost
Bid Submission
07 Jun 2022
0 days left
EMD
23200
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
kondli → Delhi
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Modification Of Electrical System Of Newly Renovated Djb Lab Including Office Complex And Other Allied Works At Kondli Stp
BOQ
| Sl. No. | Item Description |
| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. ( DSR-2018) Group C Note-switch and modular plate as per approval by engineer incharge |
| 2 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required (DSR-2018)2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 3 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required (DSR-2018)2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 4 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required (DSR-2018)2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 5 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required (DSR-2018)2 X 10 sq. mm + 1 X 6 sq. mm earth wire |
| 6 | S/F Two module Stepped type Electronic fan regulator on the existing modular plate switch box i/c connection but excluding modular plate etc as reqd. (DSR 2018) Note-Regulator as per approval by engineer incharge |
| 7 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.(DSR-2018) Note-switch/socket and modular plate as per approval by engineer incharge |
| 8 | S/F 3 pin 5 amps ceiling rose on existing switch box/wooden box i/cconnection etc as reqd |
| 9 | Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (as required) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc as reqd |
| 10 | Installation of exhaust fan in the existing opening, including makinggood the damage, connection, testing, commissioning etc as reqd. up to 450mm sweep |
| 11 | Supply of 1200mm sweep super white ceiling fan complete with capacitor, double ball bearing standard size of down rod,canopies, three nos. Blade made of aluminium alloy suitable for operation on single phase 230 Volt AC 50 HZ ( Without regulator) Make:- Usha, Crompton,Havells. |
| 12 | Supply of 450 mm sweep,exhaust fan/ fresh air fan in plastic body with louvers, Robust motor for continuous running of fan, gravity shutter to prevent entry of foreign objects like dust, bird, pets etc. operation on 230V, 50 Hz AC 3 phase supply etc. as reqd. (MR) (make: Crompton, Havelles, Usha) |
| 13 | Supplying and Fixing of Cabin / Wall fan of 400mm sweep on wall, making the hole on wall to fixing the fan, making good the damage, connection, testing and commissioning etc as reqd. (Make: Havells/Crompton/ Usha) |
| 14 | Supply of energy efficient surface/recess/panel mounted type 36W to 40W full window glare free PMMA diffuser LED panel luminaries of size 2ft x 2 ft (nominal size) fabricated with MS powder coated white CRCA housing and connections with 3 x 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc as requiredThe Total system Lumen of 36W to 40W LED should be minimum 3600 with minimum system efficacy of 100 lumen/watt colour temperature 5500K to 6500K, power factor>0.90, CRI (Ra)>75, THD <10%, with APFC driver having driver efficiency >85%, operating voltage 150-270 volts with minimum 2.5KV surge protection. . The LED chip should be of Cree, Bridge Lux, Nichia, Lumiled, Osram, Seoul. (Make: Phillips/Havells /Crompton/Wipro) |
| 15 | Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top along with 20 A \"C\" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc as reqd |
| 16 | Supplying of 4 feet nominal size LED having extruded aluminum housing, colour temperature 6500K having wattage 18-24 Watt and Lumen output not less than 2000 Lumens directly on ceiling/wall i/c connection with 1.5 sqmm FRLS PVC insulated copper conductor , Single Core Cable and earthing etc as reqd. ( Make - Philips/Havells/Crompton make) |
| 17 | Installation, testing and commissioning of pre-wired fluorescent fitting / compact fluorescent fitting of alltypes, fluorescent fitting / compact fluorescent fitting of all types,ceiling/ wall, including connections with 1.5sq. mm FRLS PVC ceiling/ wall, including connectionswith 1.5 sq. mm FRLS PVC etc as reqd. |
| 18 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (DSR-2018)8 way (4 + 24), Double door |
| 19 | Supplying and fixing of single pole 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of single pole in the existing MCBDB complete with connections, testing and commissioning etc as reqd. DSR-2018 |
| 20 | Supplying and fixingof double pole5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of single pole in the existing MCBDB complete with connections, testing and commissioning etc as reqd. DSR-2018 |
| 21 | Lead Acid battery 12 VMake:- Luminous/Okaya/Exide |
| 22 | Inverter suitable for 12 V battery. Make:- Luminous/Microtek |
| 23 | Installation, testing of Lead Acid battery with inverter including all kind of wiring, connections etc. |
| 24 | Supply of 1.5 Ton rating energy efficient inverter split Air Conditioner. Make:- Hitachi/Voltas/ Ogeneral/Daikin |
| 25 | Supply of 2.0 Tons rating energy efficient inverter split Air Conditioner |
| 26 | Installation, Testing & Commissioning of 1.5 Ton rating Air Conditioner with all copper pipes, cables, stand etc. |
| 27 | Installation, Testing & Commissioning of 2.0 Ton rating Air Conditioner with all copper pipes, cables, stand etc. |
AI Tender Summary
Tender Timeline
May 31, 2022
11:30 IST
Tender Published
Tender notice published.
CompletedJun 07, 2022
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedJun 07, 2022
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender