}

Sh Pole Painting And Repair Replacement Of Damage Cubical Panel And Feeder Pillar Etc. In Frro Lampur Rmo Electrical Mechanical Various Services Under Nesd Iii At Children Home Alipur Asha Deep Children Home Narela And Social Welfare Building In Sewa Sada, Delhi-Delhi

Public Works Department-PWD has published Sh Pole Painting And Repair Replacement Of Damage Cubical Panel And Feeder Pillar Etc. In Frro Lampur Rmo Electrical Mechanical Various Services Under Nesd Iii At Children Home Alipur Asha Deep Children Home Narela And Social Welfare Building In Sewa Sada. Submission Date for this Tender is 08-06-2022. Feeder Pillar Tenders in Delhi Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

32464419
Sh Pole Painting And Repair Replacement Of Damage Cubical Panel And Feeder Pillar Etc. In Frro Lampur Rmo Electrical Mechanical Various Services Under Nesd Iii At Children Home Alipur Asha Deep Children Home Narela And Social Welfare Building In Sewa Sada
Open Tender
Indian
Delhi
Delhi
08-06-2022

Tender Details

Sh Pole Painting And Repair Replacement Of Damage Cubical Panel And Feeder Pillar Etc. In Frro Lampur Rmo Electrical Mechanical Various Services Under Nesd Iii At Children Home Alipur Asha Deep Children Home Narela And Social Welfare Building In Sewa Sadan At Lampur Fire Station Bawana Fire Station Bhorgarh Fire Station Narela Iti Narela

Key Value

Document Fees
Refer document
EMD
INR 15629.0 /-
Tender Value
INR 7.81 Lakhs /-

BOQ Items

Name of Work:RMO Electrical & Mechanical various Services under NESD-III at Children Home, Alipur, Asha Deep Children Home, Narelaand Social Welfare building in Sewa Sadan at Lampur, Fire Station Bawana, Fire Station Bhorgarh, Fire Station Narela, ITI Narela.(SH: Pole painting and repair/replacement of damage cubical panel and feeder pillar etc. in FRRO Lampur).
Sl. No. Item Description
1Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation andrefillingthetrenchbutexcludingsandcushioning and protective covering etc., complete as required. a) 63 mm dia. (OD 63 mm & ID 51 mm Nominal)
2b) 90 mm dia. (OD 90 mm & ID 76 mm Nominal)
3Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size in the existing RCC/ HUME/ METAL pipe as required. a) Upto 35 sq. mm
4b) above 35 sqmm and Upto 95 sq. mm
5Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
6Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. a) 4 X 25 sq. mm (28mm)
7Earthing with G.I. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
8Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
9Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
10Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. a) 250 A, 25 kA,TPMCCB (Ics = 100% Icu)
11b) 150 A, 16 kA,TPMCCB (Ics = 100% Icu)
12c) 125 A, 16 kA,TPMCCB (Ics = 100% Icu)
13d) 100 A, 16 kA,TPMCCB (Ics = 100% Icu)
14Making C.C. collar of specified size and shape 1:3:6 (cement:coarse sand:graded stone agreegate 20 mm NS) i/c fixing the same existing bend pipe and plastering the collari/c paint the collar with black & white strips etc complete as reqd. (volume of pole/pipe not to be deducted)
15Supplying and fixing following electrical accessories in the existing cubical panel, DBs, feeder pillar including connection, inter connection with suitable size connectors complete etc. as required a) VAF + PF Meter, CI 0.5, Flush mounting 96 x 96 mm with CT & selector switch
16b) Phase indicating light (RYB) with MCB Control
17c) b) 3 Pole MNX 22 Power Contactor with AC1 rating of 32 A, click fit type construction having1 No. Auxiliary contact of NO and NC each
18d) Astro timer
19e) 2 Amp SPMCB for LED indication lamp
20Pole painting GI pipe pole/steel tubular swaged type (approximately upto 9 mtrs height of varying dia. approx. 100/80/65 mm dia.), MS/GI pole i/c bracket/channel/cross arms, if any, and complete removing the existing paint and rust from the surface of pole with the help of Ragmal paper and cleaning the pole with suitable acid, applying one coat of red oxide primer on complete surface of pole/angle iron/bracket/cross arm, and finally painting the pole/angle iron/bracket/cross arm with two or more coat of superior quality approved Aluminium paint to give an even shade etc as required, without damaging the street light and keeping street light free from any kind of paint/primer spot etc. complete as reqd.
21Supplying, installation, testing & commissioning of following watts aluminium body, IP66 LED flood light fitting with lens & toughened glass capable of delivering following nominal system lumens output with a minimum system efficacy more than 110 lumens /watt and a CRI greater than 70 . The luminaire shall have a life class of 50000 hours @L70 for a design ambient of 35 deg C . The inbuilt electronic driver shall operate at power factor > .95 of CCT 5700K minimum internal surge protection of 4 KV with toughened glass /polycarbonate cover LM 79/80 certification to be provided by the manufacturer for LED luminaire /LED chip .complete with all accessories i/c making connections, testing & suitable size bracket for fixing i/c dismantling the existing fitting etc. complete with all accessories etc. directly on ceiling / wall including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. a) Not less than 8800 Lumens
22Provision for pole / wall mounted box (300x200x105) mm size made out of (SMC) sheet moulding compound dust & weather proof with front openable hinged type cover with locking arrangement i/c providing & fixing of following accessories on existing pole / wall with suitable arrangement as required. a) 32 Amp 5 Way connector with bakelite base. b) 6 Amp SP MCB "C" Curve (10 KA) - 1 No. c) Earth Studs - 2 Sets. d) 40 x 5 mm clamp with 2 Nos. 3/8" Nut & Bolts - 1 Set as required. e) Push & Clip handle to close/open - 1 No.
23Supplying & Laying of one number XLPE insulated and PVC sheathed aluminium conductor, armoured underground power cable of 1.1 KV grade of following size in the existing RCC/HUME/METAL/DWC pipe as required. a) 3.5x70 sq.mm
24Fabrication, supplying, installation, testing & commissioning of outdoor type totally enclosed weather proof jointfeeder pillar / inspection box compartmentalised, fabricated from 2mm,thick CRCA sheet and with sloping canopy on the top of suitable size and as per IP-54 with suitable gasket to make it dust/vermin proof and should be fabricated from CPRI approved manufacturer with base framefabricated from 50mmx50mm x6mm thick MS angle iron with 4 legs of 100 cm. longsuitable for 415 Volt, 50HzACsupply with 3 mm thick CRCA sheet on bottomfor taking load of cable gland andnecessaryindividual gland plate for cable gland, hinged front open-able door with locking arrangementcomplete with 250 Amp. 4 strip Al. busbar 300 mm deep (NS) includinggrouting the joint feeder pillarinCC foundation coveringthree sides up to feeder pillar bottom height duly plastered i/cphosphatized & powder coated painting, connection inter connection, earthing thefeeder pillar at two separate points etc. as reqd. (manufacturers having ISO 9001 certification). Design to be get approved from E-in-C before fabrication
25Supplying, Installation, testing & Commissioning of DOL starter suitable for 3 phase motor pump of 10 HP with relay range 13-21 Amp Conforms to IS/IEC 60947-4-1 & IEC 60947-4-1. Protections Offered - Overload, Single Phasing, Phase reversal, Phase imbalance. Auto Restart Feature. Vibration proof enclosure with IP54 protection class. Indications Offered - ON/OFF, Voltage and Ampere etc as reqd.
26Supplying & Fixing of 3mm thick phenolic laminated sheet on existing switch board, loose wire box making holes etc as reqd.
27Dismantling of following items and Credit for following electrical wiring/accessories etc. as available at site of work as the old dismantle materail shall be retained with contractor:- a) Street light fitting HPSV/HPMV/MH/LED type (70 watt to 250 watt)
28b) Damage Feeder pillar/cubical panel/ with/Without Al. conductor Bus bar etc. and as and where in situation available at site.
29c) assorted size/capacity MCCB/MCB 63 amp to 250 amp with/without spreader link
30d) assorted size misc. electrical items e.g. MCB/Timer/contactor/LED indication lamp and selector switches
31e) Sintex / MS pole Box with MCB
32Add cost index @ 22.69% on DSR-2016 (item No. 1 to 8.03)Rs.
33Less 9.5% on Total value of DSR-16 & 18 (items No. 1 to 9) i/c cost index Rs.
34Total value of Market rate and DSR item after deduction of 9.5 %= 781430.64
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail